1
BLOOD GLUCOSE MONITORING SYSTEM TD-4141 TEST LIGHT INDICATOR FEATURES XPER gold strip technology Automatic recognition of quality control solution Before / After meal (AC/PC) presentable SPECIFICATIONS Enzyme Type Sample Size Reaction Time Measurement Range Hematocrit Range Precision Accuracy Communication Power Source Memory Capacity Day Average Daily Alarm Dimension Weight Operating Condition Storage Condition Units Per Carton Carton Size Cross Weight Per Carton GDH-FAD 0.5 μL 5 seconds 10~800 mg/dL (0.56~44.4mmol/L) 0% - 70% SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L); CV < 5% at 100mg/dL (5.55 mmol/L) ±15mg/dL if < 100mg/dL±15% if ö 100mg/dL Strip Port Communication AAA * 1 1000 sets 7,14,21,28,60,90 Days 4 daily alarms 97.8 (L) x 33.1 (W) x 18.2 (H) mm 29.9g (Without Battery) 8ºC(46.4ºF)~45ºC(113ºF) -20ºC(-4ºF) ~ +60ºC(140ºF) (Meter); 2ºC(35.6ºF)~30ºC(86.0ºF) (Strip) 30 340 (L) x 290 (W) x 383 (H) mm 11.1 kg SPECIFICATIONS-Accessories ACC-001 ACC-002 Bluetooth dongle USB cable www.taidoc.com B1-7F., No.127, Wugong 2nd Rd., Wugu Dist., New Taipei City 24888, Taiwan Tel : +886-2-6625-8188 Fax : +886-2-6625-0288 TaiDoc Technology Corp.

TD-4141A DM v2 - TaiDoc.com · TD-4141 TEST LIGHT INDICATOR FEATURES • XPER gold strip technology • Automatic recognition of quality control solution • Before / After meal (AC/PC)

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TD-4141A DM v2 - TaiDoc.com · TD-4141 TEST LIGHT INDICATOR FEATURES • XPER gold strip technology • Automatic recognition of quality control solution • Before / After meal (AC/PC)

BLOOD GLUCOSE MONITORING SYSTEM TD-4141

TEST LIGHT INDICATOR

FEATURES• XPER gold strip technology• Automatic recognition of quality control solution• Before / After meal (AC/PC) presentable

SPECIFICATIONSEnzyme Type

Sample Size

Reaction Time

Measurement Range

Hematocrit Range

Precision

Accuracy

Communication

Power Source

Memory Capacity

Day Average

Daily Alarm

Dimension

Weight

Operating Condition

Storage Condition

Units Per Carton

Carton Size

Cross Weight Per Carton

GDH-FAD

0.5 µL

5 seconds

10~800 mg/dL (0.56~44.4mmol/L)

0% - 70%

SD < 5 mg/dL (0.278 mmol/L) at < 100mg/dL (5.55 mmol/L);

CV < 5% at 100mg/dL (5.55 mmol/L)

±15mg/dL if < 100mg/dL;±15% if ≧ 100mg/dL

Strip Port Communication

AAA * 1

1000 sets

7,14,21,28,60,90 Days

4 daily alarms

97.8 (L) x 33.1 (W) x 18.2 (H) mm

29.9g (Without Battery)

8ºC(46.4ºF)~45ºC(113ºF)

-20ºC(-4ºF) ~ +60ºC(140ºF) (Meter); 2ºC(35.6ºF)~30ºC(86.0ºF) (Strip)

30

340 (L) x 290 (W) x 383 (H) mm

11.1 kg

SPECIFICATIONS-AccessoriesACC-001

ACC-002

Bluetooth dongle

USB cable

www.taidoc.com

B1-7F., No.127, Wugong 2nd Rd., Wugu Dist., New Taipei City 24888, TaiwanTel : +886-2-6625-8188 Fax : +886-2-6625-0288

TaiDoc Technology Corp.