36
Configurator 2011-2012 Endress+Hauser Consult AG Kägenstrasse 2 CH - 4153 Reinach System Component: Tank Gauging. Protocol conversion. Application: Communication protocols conversion, remote display. Protocol conversion in real time, gauge command support. :: Seamless integration of different vendor gauges into one Tank Gauging System. :: Upgrades of sites gradual. SPK: NFI 71115426 Tankvision Field Link NXA30 NXA30- Tankvision Field Link NXA30 Approval: Non-hazardous area AA Version: Protocol conversion, loop FC Special version, TSP-no. to be spec. YY Housing: DIN Rail D Special version, TSP-no. to be spec. Y Field Input: xxx x Enraf GPU/BPM OE xxx x Saab TRL2 OX Special version, TSP-no. to be spec. 99 Field Output: Modbus RTU RS485 T5 Special version, TSP-no. to be spec. 99 System Component: Tank Gauging. Calculation, Monitoring. Up to 400 tanks Application: system architecture, loops + protocols multiple, customization. Inventory calculations acc. API/ASTM. Web server: Multi-user interface. Archiving + reporting. Connection > Tankvision Multi Scan. :: High flexibility through a maximum choice on interfaces . :: Easiest adaption to user specific requirements. SPK: NFI 71114130 Tankvision Professional NXA85 NXA85- Tankvision Professional NXA85 Version: Stand alone A Server S Measuring: <= 10 tanks 1 <= 30 tanks 2 <= 50 tanks 3 <= 100 tanks 4 > 100 tanks 5 Operation Language: English AA Special version, TSP-no. to be spec. 99 >>Application Package: Product movements EA Backup Scheduler EB Page 1 / 36

Tankvision Field Link NXA30

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

System Component: Tank Gauging.

Protocol conversion.

Application: Communication

protocols conversion, remote

display.

Protocol conversion in real time,

gauge command support.

:: Seamless integration of different

vendor gauges into one

Tank Gauging System.

:: Upgrades of sites gradual.

SPK: NFI

71115426

Tankvision Field Link NXA30

NXA30-

Tankvision Field Link NXA30

Approval:

Non-hazardous area AA

Version:

Protocol conversion, loop FC

Special version, TSP-no. to be spec. YY

Housing:

DIN Rail D

Special version, TSP-no. to be spec. Y

Field Input:

xxx x Enraf GPU/BPM OE

xxx x Saab TRL2 OX

Special version, TSP-no. to be spec. 99

Field Output:

Modbus RTU RS485 T5

Special version, TSP-no. to be spec. 99

System Component: Tank Gauging.

Calculation, Monitoring.

Up to 400 tanks

Application: system architecture,

loops + protocols multiple,

customization.

Inventory calculations acc. API/ASTM.

Web server: Multi-user interface.

Archiving + reporting.

Connection > Tankvision Multi Scan.

:: High flexibility through a maximum

choice on interfaces .

:: Easiest adaption to user specific

requirements.

SPK: NFI

71114130

Tankvision Professional NXA85

NXA85-

Tankvision Professional NXA85

Version:

Stand alone A

Server S

Measuring:

<= 10 tanks 1

<= 30 tanks 2

<= 50 tanks 3

<= 100 tanks 4

> 100 tanks 5

Operation Language:

English AA

Special version, TSP-no. to be spec. 99

>>Application Package:

Product movements EA

Backup Scheduler EB

Page 1 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

SCADA run time license EC

SCADA design time licene ED

Redundancy support EE

Special version, TSP-no. to be spec. EY

>Application Package Client:

xxx x Client E1

>Input Multi Scan:

xxx x Multi Scan MC

>Input Modbus:

xxx x Modbus M4

>Input Whessoe WM550:

xxx x Whessoe WM550 M1

>Input Enraf CIU 858 GPU/RS232:

xxx x Enraf CIU 858 GPU/RS232 MN

>Input Enraf CIU Prime GPU/RS232:

xxx x Enraf CIU Prime GPU/RS232 MP

>Input Saab FCU2160:

xxx x Saab FCU 2160 MX

>Input OPC Client:

xxx x OPC Client NF

>Input Special Version:

Special version, TSP-no. to be spec. N9

>Output Modbus RTU:

xxx x Modbus RTU R4

>Output Modbus TCP:

xxx x Modbus TCP RJ

>Output Special Version:

Special version, TSP-no. to be spec. S9

>OPC Server (Ethernet) Output:

Data Access 1x connection VA

Data Access 2-5x connection concurrent VB

Data Access >5x connection concurrent VC

>Web Server Output:

2-5x connection concurrent WB

6-10x connection concurrent WC

11-15x connection concurrent WD

>15x connection concurrent WE

Transmits data to other host units like

PLC or DCS systems.

Connects via Ethernet up to

15 NXA820/NXA821.

SPK: NFI

71025617

Tankvision Host Link NXA822

NXA822-

Tankvision Host Link NXA822

Approval:

Non-hazardous area A

Communication; Output:

MODBUS serial; TCP/IP, Entis+ slave interface 1

Special version, TSP-no. to be spec. 9

Power Supply:

90-250VAC 50/60Hz 1

10.5-32VDC 2

Page 2 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Special version, TSP-no. to be spec. 9

Local Operation:

status display 1

Special version, TSP-no. to be spec. 9

Operation Language:

English A

Special version, TSP-no. to be spec. Y

Housing:

DIN rail mounting PBT, IP20 1

Special version, TSP-no. to be spec. 9

Redundancy:

w/o 1

Special version, TSP-no. to be spec. 9

Custody Transfer Approval:

not selected 0

Special version, TSP-no. to be spec. 9

Additional Option:

Basic version A

Special version, TSP-no. to be spec. Y

Connects up to 225 tanks or max 15

NXA820 and supports product sorting and

summarizing via a built-in HTML user

Interface, standby redundancy.

SPK: NFI

71025616

Tankvision Data Concentrator NXA821

NXA821-

Tankvision Data Concentrator NXA821

Approval:

Non-hazardous area A

Power Supply:

90-250VAC 50/60Hz 1

10.5-32VDC 2

Special version, TSP-no. to be spec. 9

Data Archive Memory Size:

1GB D

Special version, TSP-no. to be spec. Y

Local Operation:

status display 1

Special version, TSP-no. to be spec. 9

Operation Language:

English A

Special version, TSP-no. to be spec. Y

Housing:

DIN rail mounting PBT, IP20 1

Special version, TSP-no. to be spec. 9

Redundancy:

w/o 1

Special version, TSP-no. to be spec. 9

Custody Transfer Approval:

not selected 0

NMi type approval 1

PTB type approval 7

Special version, TSP-no. to be spec. 9

Page 3 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Additional Option:

Basic version A

Printer port, serial, W+M approved P

Special version, TSP-no. to be spec. Y

Connects to a single field loop with

tank gauging instruments.

It polls instruments on one field loop

and provides measured data on an

Ethernet port for other Tankvision

units.

Configuration and visualization via

built-in HTML based user interface.

Connects up to 15 tanks.

SPK: NFI

71025615

Tankvision Tank Scanner NXA820

NXA820-

Tankvision Tank Scanner NXA820

Approval:

Non-hazardous area A

Field Communication; Input:

Sakura V1 protocol; max 10 instruments 8

Whessoematic 550; max 15 instruments 1

MODBUS EIA485 master; max 15 instruments 4

Special version, TSP-no. to be spec. Y

Power Supply:

90-250VAC 50/60Hz 1

10.5-32VDC 2

Special version, TSP-no. to be spec. 9

Inventory Calculation:

Oil+gas 1

Special version, TSP-no. to be spec. 9

Data Archive Memory Size:

1GB D

Special version, TSP-no. to be spec. Y

Local Operation:

status display 1

Special version, TSP-no. to be spec. 9

Operation Language:

English A

Special version, TSP-no. to be spec. Y

Housing:

DIN rail mounting PBT, IP20 1

Special version, TSP-no. to be spec. 9

Redundancy:

w/o 1

Special version, TSP-no. to be spec. 9

Custody Transfer Approval:

not selected 0

NMI type approval 1

PTB type approval 7

Special version, TSP-no. to be spec. 9

Additional Option:

Basic version A

Special version, TSP-no. to be spec. Y

Page 4 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

System Component: Tank Gauging.

Data collection, Calculation,

Monitoring.

Up to 250 tanks.

Application: system architecture mixed,

Fieldbus loops + protocols multiple.

Inventory calculations acc. API/ASTM.

Web server: multi-user interface,

operating system independant.

:: Stand-alone/integrated

into larger system.

:: Upgrades of sites gradual.

SPK: NFI

71115427

Tankvision Multi Scan NXA83

NXA83-

Tankvision Multi Scan NXA83

Approval:

Non-hazardous area AA

Version:

Stand alone A

Redundancy support E

Special version, TSP-no. to be spec. Y

Housing:

Wall mounted H

19" Rack Montage - 8 channels R

19" Rack Montage - 16 channels T

Special version, TSP-no. to be spec. Y

Operation Language:

English AA

Special version, TSP-no. to be spec. 99

Field Protocol (input 1):

xxx x HART OH

xxx x Modbus RTU RS485 O5

xxx x Whessoe WM550 O1

xxx x Enraf GPU/BPM OE

xxx x Saab TRL2 OX

xxx x Scientific Instruments SI6290 PD

Special version, TSP-no. to be spec. 99

>Input HART:

xxx x HART OH

>Input Modbus RTU RS485:

xxx x Modbus RTU RS485 O5

>Input Whessoe WM550:

xxx x Whessoe WM550 O1

>Input Enraf GPU/BPM:

xxx x Enraf GPU/BPM OE

>Input Saab TRL2:

xxx x Saab TRL2 OX

>Input Scientific Instruments:

xxx x Scientific Instruments SI6290 PD

>Input Special Version:

Special version, TSP-no. to be spec. O9

>Output Multi Scan RS232:

xxx x Multi Scan RS232 TC

>Output Multi Scan RS485:

xxx x Multi Scan RS485 TD

>Output Multi Scan TCP:

xxx x Multi Scan Ethernet TCP TF

>Output Modbus RTU RS232:

xxx x Modbus RTU RS232 T4

Page 5 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

>Output Modbus RTU RS485:

xxx x Modbus RTU RS485 T5

>Output Modbus TCP:

xxx x Modbus TCP TJ

>Output Special Version:

Special version, TSP-no. to be spec. T9

>OPC Server (Ethernet) Output:

Data Access 1x connection VA

Data Access 2-5x connection concurrent VB

Data Access >5x connection concurrent VC

>>Hardware Option:

Touch screen XA

Special version, TSP-no. to be spec. X9

Level gauge based on servo principle.

For operation in process + storage

tanks, beverage, food stuff liquid

measurement.

SPK: NSA

52005626

Proservo NMS7 (Sanitary)

NMS7-

Proservo NMS7 (Sanitary)

Approval:

Weather proof, IP67 NEMA4X 0

TIIS Ex d IIB T4 1

Special version, TSP-no. to be spec. 9

Application:

Liquid level A

Liquid level, I/F level, density B

Special version, TSP-no. to be spec. Y

Output 1:

Not selected F

2-way 2-wire (V1 protocol) A

2-way 2-wire (BBB protocol) B

2-way 2-wire (MIC, RS232C protocol) C

2-way 2-wire (MIC protocol) D

2-way 2-wire (MDP protocol) J

4-20mA HART active G

4-20mA HART passive H

Whessmatic 550, overvoltage protection L

Mark Space M

Enraf BPM N

Modbus RS485 P

Special version, TSP-no. to be spec. Y

Output 2:

Not selected 0

4x relay SPST 1

2x 4-20mA 2

4x relay SPST, 2x 4-20mA 3

2x relay SPST, overfill prevention 4

Special version, TSP-no. to be spec. 9

Input:

HART (NMT5xx, NRF560, pressure transmitter) 0

1x spot temperature Pt100, HART (NMT5xx, NRF560, pressure transmitter) 1

2x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 2

1x spot temperature Pt100, 2x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 3

Page 6 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Special version, TSP-no. to be spec. 9

Measuring Range; Wire:

0-16m; SUS316, 0.2mm B

0-16m; PFA>SUS316, 0.4mm D

Special version, TSP-no. to be spec. Y

Cable Entry:

4x thread G1/2 A

4x thread G3/4 B

4x thread NPT1/2 C

4x thread NPT3/4 D

4x thread M20 G

4x thread M25 H

Special version, TSP-no. to be spec. Y

Process Connection:

10K 80A RF, SUS304 flange JIS B2220 A

10K 80A FF, SUS304 flange JIS B2220 B

3" 150lbs RF, SUS304 flange ANSI B16.5 C

DN80 PN10 B1, SUS304 flange EN1092-1 (DIN2527 B) D

80A 150lbs RF, SUS304 flange JPI 7S-15 E

Special version, TSP-no. to be spec. Y

Power Supply:

85-264VAC, 50/60Hz 0

20-62VDC, 20-55VAC, 50/60Hz 1

Special version, TSP-no. to be spec. 9

Displacer:

Cylindrical 50mm, SUS316 polished A

Cylindrical 40mm, SUS316 polished B

Cylindrical 30mm, SUS316 polished C

Cylindrical 50mm, PTFE D

Cylindrical 40mm, PTFE E

Cylindrical 30mm, PTFE F

Special version, TSP-no. to be spec. Y

O-ring; Drum Housing Inner Finish:

NBR; milled 0

Silicone rubber; polished 1

FKM; not selected 2

Silicone rubber; FEP coated 5

Special version, TSP-no. to be spec. 9

Nozzle:

Rc3/8, cleaning A

NPT3/8, cleaning B

G3/8, cleaning C

Rc3/8, gas purging D

NPT3/8, gas purging E

G3/8, gas purging F

Rc3/8, cleaning, gas purging G

NPT3/8, cleaning, gas purging H

G3/8, cleaning, gas purging J

Special version, TSP-no. to be spec. Y

Additional Option:

Not selected A

Custody transfer seal, wire lock B

Cleaned from oil+grease C

Sunshade D

Cleaned from oil+grease, custody transfer seal, wire lock E

Sunshade, custody transfer seal, wire lock F

Sunshade, cleaned from oil+grease G

Sunshade, cleaned from oil+grease, custody transfer seal, wire lock H

Special version, TSP-no. to be spec. Y

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Page 7 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

For operation in storage tanks with

liquids like oils, fuels, LPG etc. in

hazardous areas.

Interface-level and density measurement

optional. SPK: NSA

017402-9000

Proservo NMS5

NMS5-

Proservo NMS5

Drum Housing Pressure Rating; Material:

0… 200mbar/20kPa/2.9psi; Alu 1

0… 200mbar/20kPa/2.9psi; stainless steel 2

0… 5.88bar/588kPa/85.28psi; Alu 4

0… 5.88bar/588kPa/85.28psi; stainless steel 5

0… 24.5bar/2.45MPa/355.34psi; stainless steel 6

Special version, TSP-no. to be spec. 9

Approval:

Weather proof, IP67 NEMA4X 0

TIIS Ex d IIB T4 1

FM XP Cl. I Div.1 Gr.C-D 5

FM XP-AIS Cl.I Div.1 Gr.C-D N

CSA Cl. I Div.1 Gr.C-D 6

CSA Ex d(ia) Cl. I Div.1 Gr.C-D O

ATEX II 1/2G Ex d IIB T4, T3 G

ATEX II 1/2G Ex d IIC T4, T3 Q

ATEX II 1/2G Ex d IIB T4, T3, -40oC S

ATEX II 1/2G Ex d (ia) IIB T4, T3 J

ATEX II 1/2G Ex d (ia) IIB T4,T3, -40oC U

IEC Ex d ia IIB T4,T3 Ga/Gb A

IEC Ex d IIB T4,T3 Ga/Gb B

IEC Ex d IIC T4,T3 Ga/Gb C

IEC Ex d ia IIB T4,T3 Ga/Gb, -40oC D

IEC Ex d IIB T4,T3 Ga/Gb, -40oC E

Special version, TSP-no. to be spec. 9

Application:

Liquid level A

PTB (<1mm) type approval, liquid level B

NMi (<1mm) type approval, liquid level C

Multi measurement, Liquid level, I/F level, bottom, density D

PTB (<1mm) type approval, liquid level, I/F level, bottom, density E

NMi (<1mm) type approval, liquid level, I/F level, bottom, density F

Density profile multi measurement, Liquid level, I/F level, bottom, density G

PTB (<1mm) type approval, density profile, liquid level, I/F level, bottom, density H

NMi (<1mm) type approval, density profile, liquid level, I/F level, bottom, density J

Special version, TSP-no. to be spec. Y

Output 1:

Not selected F

2-way 2-wire (V1 protocol) A

2-way 2-wire (MDP protocol) J

2-way 2-wire (BBB protocol) B

2-way 2-wire (MIC, RS232C protocol) C

2-way 2-wire (MIC protocol) D

4-20mA HART active G

4-20mA HART passive H

Whessmatic 550, overvoltage protection L

Mark Space M

Enraf BPM N

Modbus RS485 P

Special version, TSP-no. to be spec. Y

Page 8 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Output 2:

Not selected 0

4x relay SPST 1

2x 4-20mA 2

4x relay SPST, 2x 4-20mA 3

2x relay SPST, overfill prevention TÜV 4

4x relay SPST, 1x 4-20mA 5

Special version, TSP-no. to be spec. 9

Input:

HART (NMT5xx, NRF560, pressure transmitter) 0

1x spot temperature Pt100, HART (NMT5xx, NRF560, pressure transmitter) 1

2x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 2

1x spot temperature Pt100, 2x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 3

1x status, HART (NMT5xx, NRF560, pressure transmitter) 4

1x spot temperature Pt100, 1x status, HART (NMT5xx, NRF560, pressure transmitter) 5

1x spot temperature Pt100, 1x status, 2x operation contact, HART (NMT5xx, NRF560, pressure transmitter) 6

Special version, TSP-no. to be spec. 9

Measuring Range; Wire:

0-28m; SUS316, 0.15mm C

0-36m; SUS316, 0.15mm L

0-16m; PFA>SUS316, 0.4mm H

0-16m; AlloyC, 0.2mm K

0-22m; AlloyC, 0.2mm M

*0-47m; SUS316, 0.15mm N

Special version, TSP-no. to be spec. Y

Cable Entry:

4x thread G1/2 E

4x thread G3/4 F

4x thread NPT1/2 G

4x thread NPT3/4 H

4x thread M20 L

4x thread M25 M

Special version, TSP-no. to be spec. Y

Process Connection:

10K 80A RF, flange JIS B2220 A

10K 80A FF, flange JIS B2220 C

10K 150A RF, flange JIS B2220 U

20K 80A RF, flange JIS B2220 E

3" 150lbs RF, flange ANSI B16.5 G

3" 300lbs RF (apply for NMS5-6), flange ANSI B16.5 J

6" 150lbs RF, flange ANSI B16.5 T

DN80 PN10 B1, flange EN1092-1 (DIN2527 B) L

DN80 PN25 B1, flange EN1092-1 (DIN2527 B) N

80A 150lbs RF, flange JPI 7S-15 Q

80A 300lbs RF (apply for NMS5-6), flange JPI 7S-15 S

Special version, TSP-no. to be spec. Y

Power Supply:

85-264VAC, 50/60Hz 3

20-62VDC, 20-55VAC, 50/60Hz 4

Special version, TSP-no. to be spec. 9

Displacer:

Cylindrical 30mm, SUS316 N

Cylindrical 40mm, SUS316 K

Cylindrical 50mm, SUS316 D

Cylindrical 50mm, AlloyC T

Conical 70mm, SUS316 R

Conical 110mm, SUS316 S

Special version, TSP-no. to be spec. Y

O-ring; Drum Housing Inner Finish:

NBR; not selected 0

Page 9 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Silicone rubber; not selected 1

Silicone rubber; FEP coated 5

PTFE (wire drum FKM); not selected 3

PTFE (wire drum FKM); FEP coated 4

CR; not selected 6

FKM; not selected 2

Special version, TSP-no. to be spec. 9

Additional Option:

Not selected A

Rc3/8 cleaning nozzle C

Rc3/8 gas purging nozzle D

Guide wire installation E

Relief valve G

Relief valve, pressure gauge H

Sunshade J

Rc3/8 gas purging nozzle, sunshade L

Special version, TSP-no. to be spec. Y

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Magnet float type tank gauge by flange

mounting with numeric display.

SPK: NSB

52007808

Float Gauge LT1222

LT1222-

Float Gauge LT1222

Function:

Basic version 0

Special version, TSP-no. to be spec. 9

Process Connection:

10K 40A RF, flange JIS B2220 1

1-1/2" 150lbs RF, flange ANSI B16.5 2

Special version, TSP-no. to be spec. 9

Measuring Range:

2.5m 1

5m 2

Special version, TSP-no. to be spec. 9

Display:

Numeric (mechanical counter) 2

Application:

Gauge head only 000

Seal pipe not selected 212

Seal pipe SUS316 214

Seal pipe PVC, wetted/gas parts 215

Special version, TSP-no. to be spec. 999

Seal Pipe:

Not selected 0

xxx mm 10K 40A RF, SUS316 flange JIS B2220 1

xxx mm 20K 40A RF, SUS316 flange JIS B2220 2

xxx mm 10K 50A FF, PVC flange JIS B2220 3

xxx mm 1-1/2" 150lbs RF, SUS316 flange ANSI B16.5 4

xxx mm 1-1/2" 300lbs RF, SUS316 flange ANSI B16.5 5

xxx mm 2" 150lbs FF, PVC flange ANSI B16.5 6

Special version, TSP-no. to be spec. 9

Float:

Page 10 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Not selected 0

Low pressure, SUS316 1

High pressure, SUS316 2

Special version, TSP-no. to be spec. 9

Colour:

Silver 0

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Magnet float type tank gauge by screw

mounting with numeric display.

SPK: NSB

52007806

Float Gauge LT1122

LT1122-

Float Gauge LT1122

Function:

Basic version 0

Special version, TSP-no. to be spec. 9

Process Connection:

Thread JIS B0203 Rp1-1/2 0

Thread JIS B0203 Rc1-1/2, union nut 6

Thread ANSI NPT1-1/2, union nut 7

Special version, TSP-no. to be spec. 9

Measuring Range:

2.5m 1

5m 2

Special version, TSP-no. to be spec. 9

Display:

Numeric (mechanical counter) 2

Application:

Gauge head only 000

Seal pipe not selected 202

Seal pipe SUS316 204

Seal pipe PVC, wetted/gas parts 205

Special version, TSP-no. to be spec. 999

Seal Pipe:

Not selected 0

xxx mm 10K 40A RF, SUS316 flange JIS B2220 1

xxx mm 20K 40A RF, SUS316 flange JIS B2220 2

xxx mm 10K 50A FF, PVC flange JIS B2220 3

xxx mm 1-1/2" 150lbs RF, SUS316 flange ANSI B16.5 4

xxx mm 1-1/2" 300lbs RF, SUS316 flange ANSI B16.5 5

xxx mm 2" 150lbs FF, PVC flange ANSI B16.5 6

Special version, TSP-no. to be spec. 9

Float:

Not selected 0

Low pressure, SUS316 1

High pressure, SUS316 2

Special version, TSP-no. to be spec. 9

Colour:

Silver 0

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Page 11 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Tagging (TAG), see additional spec. 1

Float type tank gauge with flange

mounting type under high pressure

application (2.5MPa/25bar).

SPK: NSB

52007804

Float Gauge LT16 (LT1600)

LT16-

Float Gauge LT16 (LT1600)

Display:

Dial 2 pointers 1

Numeric (mechanical counter) 2

Dial 2 pointers, up side down 5

Special version, to be specified 9

Crank Unit:

Not selected 0

Selected 1

Function:

Basic version 0

Special version, TSP-no. to be spec. 9

Process Connection:

10K 40A RF, SCPL1, SNB7 flange JIS B2220 1

20K 40A RF, SCPL1, SNB7 flange JIS B2220 2

10K 40A RF, SCS13, SUS304 flange JIS B2220 A

20K 40A RF, SCS13, SUS304 flange JIS B2220 B

20K 40A RF, SCS13, SNB7 flange JIS B2220 G

1-1/2" 150lbs RF, SCPL1, SNB7 flange ANSI B16.5 3

1-1/2" 300lbs RF, SCPL1, SNB7 flange ANSI B16.5 4

1-1/2" 150lbs RF, SCS13, SUS304 flange ANSI B16.5 C

1-1/2" 300lbs RF, SCS13, SUS304 flange ANSI B16.5 D

1-1/2" 300lbs RF, SCS13, SNB7 flange ANSI B16.5 H

40A 150lbs RF, SCLP1, SNB7 flange JPI 7S-15 5

40A 300lbs RF, SCLP1, SNB7 flange JPI 7S-15 6

40A 150lbs RF, SCS13, SUS304 flange JPI 7S-15 E

40A 300lbs RF, SCS13, SUS304 flange JPI 7S-15 F

40A 300lbs RF, SCS13, SNB7 flange JPI 7S-15 J

Special version, TSP-no. to be spec. 9

Measuring Range:

2.5m 1

5m 2

10m 3

16m 4

20m 5

30m 6

Special version, TSP-no. to be spec. 9

Application:

Gauge head only, accessories ordered by selection tool AAA

Gauge head only 000

Standard, sheave elbow 90o x1, 135o x2 042

Sheave elbow 90o x2 043

Tank top installation 044

Standard, sheave elbow 90o x1, 135o x2, crank unit 096

Sheave elbow 90o x2, crank unit 097

Special version, TSP-no. to be spec. 999

Float:

Not selected 4

8.3kg, d=400mm 5

Page 12 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Special version, TSP-no. to be spec. 9

Additional Option:

Basic version 0

Gauge head bolts SUS304 B

Copper free C

Copper free, gauge head bolts SUS304 F

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Float type tank gauge with flange

mounting type under middle pressure

application (0.1MPa/1.0bar).

SPK: NSB

52007803

Float Gauge LT14 (LT1400)

LT14-

Float Gauge LT14 (LT1400)

Display:

Dial 2 pointers 1

Numeric (mechanical counter) 2

Dial 2 pointers, up side down 5

Special version, TSP-no. to be spec. 9

Crank Unit:

Not selected 0

Selected 1

Function:

Basic version 0

Special version, TSP-no. to be spec. 9

Process Connection:

10K 40A RF, AC4CT6 flange JIS B2220 1

10K 40A RF, SCS13 flange JIS B2220 A

1-1/2" 150lbs RF, AC4CT6 flange ANSI B16.5 3

1-1/2" 150lbs RF, SCS13 flange ANSI B16.5 C

40A 150lbs RF, AC4CT6 flange JPI 7S-15 5

40A 150lbs RF, SCS13 flange JPI 7S-15 E

Special version, TSP-no. to be spec. 9

Measuring Range:

2.5m 1

5m 2

10m 3

16m 4

20m 5

30m 6

Special version, TSP-no. to be spec. 9

Application:

Gauge head only, accessories ordered by selection tool AAA

Gauge head only 000

Standard, sheave elbow 90o x2 040

Wetted/gas parts SUS316, sheave elbow 90o x1, 135o x2 041

Alu, sheave elbow 90o x1, 135o x2 078

Standard, sheave elbow 90o x2, crank unit 094

Wetted/gas parts SUS316, crank unit, sheave elbow 90o x1, 135o x2 095

Alu, sheave elbow 90o x1, 135o x2, crank unit 098

Special version, TSP-no. to be spec. 999

Float:

Not selected 4

Page 13 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

8.0kg, d=400mm 5

Special version, TSP-no. to be spec. 9

Additional Option:

Basic version 0

Copper free C

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Float type tank gauge according to wire

float type under low pressure

application (20kPa/0.2bar).

Display position: upper.

SPK: NSB

52007809

Float Gauge LTC2230

LTC2230-

Float Gauge LTC2230

Function:

Basic version 0

Special version, TSP-no. to be spec. 9

Process Connection:

10K 150A RF, SS400 flange JIS B2220 0

6" 150lbs RF, SS400 flange ANSI B16.5 1

Special version, TSP-no. to be spec. 9

Measuring Range:

2.5m 1

5m 2

10m 3

Special version, TSP-no. to be spec. 9

Display:

Dial 1 pointer 1

Special version, TSP-no. to be spec. 9

Application:

Gauge head only 000

Standard application 081

Special version, TSP-no. to be spec. 999

Float:

2.1kg, d=140mm (0.5-0.93g/cm3) 1

2.4kg, d=140mm (0.94-2.0g/cm3) 2

Not selected 3

Special version, TSP-no. to be spec. 9

Colour:

Silver 0

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Page 14 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Float type tank gauge with screw

mounting type under low pressure

application (20kPa/0.2bar).

SPK: NSB

52007801

Float Gauge LT11 (LT1100)

LT11-

Float Gauge LT11 (LT1100)

Display:

Dial 2 pointers 1

Numeric (mechanical counter) 2

Dial 2 pointers, up side down 5

Special version, TSP-no. to be spec. 9

Crank Unit:

Not selected 0

Selected 1

Function:

Basic version 0

Special version, TSP-no. to be spec. 9

Process Connection:

Thread JIS B0203 Rp 1-1/2, w/o union nut, SUS316 0

Thread JIS B0203 Rc 1-1/2, union nut, sleeve, SUS316 A

Thread ANSI NPT1-1/2, union nut, sleeve, SUS316 B

Thread JIS B0202 G1-1/2, union nut, sleeve, SUS316 C

Special version, TSP-no. to be spec. 9

Measuring Range:

2.5m 1

5m 2

10m 3

16m 4

20m 5

30m 6

Special version, TSP-no. to be spec. 9

Application:

Gauge head only, accessories ordered by selection tool AAA

Gauge head only 000

CRT, guide pipe installation 005

Tank top, guide pipe installation 008

PVC, SS400 wire hook 060

PVC, SUS316 wire hook 062

Gas holder 251

FRT tank 261

Standard application for CRT, tape not installed, (solid guide wire, 2 anchor hooks) A01

Wetted parts SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A04

Wetted/gas parts SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A06

Underground standard, tape not installed, (solid guide wire, 2 anchor hooks) A07

Underground standard, SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A10

Seal pot standard, tape not installed, (solid guide wire, 2 anchor hooks) A50

Seal pot all SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A54

Standard, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B01

Wetted parts SUS316, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B04

Wetted/gas parts SUS316, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B06

Seal pot standard, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B50

Seal pot SUS316, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B54

Underground tank installation, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) C07

Underground tank installation, tape not installed, (solid guide wire, 2 anchor hooks) C10

Special version, TSP-no. to be spec. 999

Page 15 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Float:

Not selected 4

4.2kg, d=400mm 1

5.0kg, d=400mm 2

8.0kg, d=400mm 3

2.1kg, d=140mm 5

2.4kg, d=140mm 6

Special version, TSP-no. to be spec. 9

Additional Option:

Basic version 0

Copper free C

Glass display cover D

Copper free, glass display cover J

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Magnet float type tank gauge by flange

mounting with dial display.

SPK: NSB

52007807

Float Gauge LT1212

LT1212-

Float Gauge LT1212

Function:

Basic version 0

Special version, TSP-no. to be spec. 9

Process Connection:

10K 40A RF, flange JIS B2220 1

1-1/2" 150lbs RF, flange ANSI B16.5 2

Special version, TSP-no. to be spec. 9

Measuring Range:

2.5m 1

5m 2

Special version, TSP-no. to be spec. 9

Display:

Dial 2 pointers 1

Special version, TSP-no. to be spec. 9

Application:

Gauge head only 000

Seal pipe not selected 212

Seal pipe SUS316 214

Seal pipe PVC, wetted/gas parts 215

Special version, TSP-no. to be spec. 999

Seal Pipe:

Not selected 0

xxx mm 10K 40A RF, SUS316 flange JIS B2220 1

xxx mm 20K 40A RF, SUS316 flange JIS B2220 2

xxx mm 10K 50A FF, PVC flange JIS B2220 3

xxx mm 1-1/2" 150lbs RF, SUS316 flange ANSI B16.5 4

xxx mm 1-1/2" 300lbs RF, SUS316 flange ANSI B16.5 5

xxx mm 2" 150lbs FF, PVC flange ANSI B16.5 6

Special version, TSP-no. to be spec. 9

Float:

Not selected 0

Low pressure, SUS316 1

Page 16 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

High pressure, SUS316 2

Special version, TSP-no. to be spec. 9

Colour:

Silver 0

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Float type tank gauge with flange

mounting type under low pressure

application (20kPa/0.2bar).

SPK: NSB

52007802

Float Gauge LT12 (LT1200)

LT12-

Float Gauge LT12 (LT1200)

Display:

Dial 2 pointers 1

Numeric (mechanical counter) 2

Dial 2 pointers, up side down 5

Special version, TSP-no. to be spec. 9

Crank Unit:

Not selected 0

Selected 1

Function:

Basic version 0

Special version, TSP-no. to be spec. 9

Process Connection:

10K 40A RF, AC4A flange JIS B2220 1

10K 40A RF, SUS316 flange JIS B2220 A

1-1/2" 150lbs RF, AC4C flange ANSI B16.5 2

1-1/2" 150lbs RF, SUS316 flange ANSI B16.5 B

40A 150lbs RF, AC4A flange JPI 7S-15 3

40A 150lbs RF, SUS316 flange JPI 7S-15 C

Special version, TSP-no. to be spec. 9

Measuring Range:

2.5m 1

5m 2

10m 3

16m 4

20m 5

30m 6

Special version, TSP-no. to be spec. 9

Application:

Gauge head only, accessories ordered by selection tool AAA

Gauge head only 000

PVC, SS400 wire hook 061

PVC, SUS316 wire hook 063

Gas holder 252

FRT tank 262

Standard application for CRT, tape not installed, (solid guide wire, 2 anchor hooks) A11

Wetted parts SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A14

Wetted/gas parts SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A15

Underground standard, tape not installed, (solid guide wire, 2 anchor hooks) A40

Underground standard, SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A43

Standard, seal pot, tape not installed, (solid guide wire, 2 anchor hooks) A55

Seal pot all SUS316, tape not installed, (solid guide wire, 2 anchor hooks) A59

Page 17 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Standard, seal pot, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B55

Seal pot all SUS316, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B59

Standard, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B11

Wetted parts SUS316, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B14

Wetted/gas parts SUS316, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B15

Underground tank installation, crank unit, tape not installed, (solid guide wire, 2 anchor hooks) B40

UTI, wetted parts SUS316, crank unit, tape not installed, UTI = Underground tank installation (solid guide wire, 2 anchor hooks) B43

Special version, TSP-no. to be spec. 999

Float:

Not selected 4

4.2kg, d=400mm 1

5.0kg, d=400mm 2

8.0kg, d=400mm 3

Special version, TSP-no. to be spec. 9

Additional Option:

Basic version 0

Copper free C

Glass display cover D

Copper free, glass display cover J

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Magnet float type tank gauge by screw

mounting with dial display.

SPK: NSB

52007805

Float Gauge LT1112

LT1112-

Float Gauge LT1112

Function:

Basic version 0

Special version, TSP-no. to be spec. 9

Process Connection:

Thread JIS B0203 Rp1-1/2 0

Thread JIS B0203 Rc1-1/2, union nut 6

Thread ANSI NPT1-1/2, union nut 7

Special version, TSP-no. to be spec. 9

Measuring Range:

2.5m 1

5m 2

Special version, TSP-no. to be spec. 9

Display:

Dial 2 pointers 1

Special version, TSP-no. to be spec. 9

Application:

Gauge head only 000

Seal pipe not selected 202

Seal pipe SUS316 204

Seal pipe PVC, wetted/gas parts 205

Special version, TSP-no. to be spec. 999

Seal Pipe:

Not selected 0

Page 18 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

xxx mm 10K 40A RF, SUS316 flange JIS B2220 1

xxx mm 20K 40A RF, SUS316 flange JIS B2220 2

xxx mm 10K 50A FF, PVC flange JIS B2220 3

xxx mm 1-1/2" 150lbs RF, SUS316 flange ANSI B16.5 4

xxx mm 1-1/2" 300lbs RF, SUS316 flange ANSI B16.5 5

xxx mm 2" 150lbs FF, PVC flange ANSI B16.5 6

Special version, TSP-no. to be spec. 9

Float:

Not selected 0

Low pressure, SUS316 1

High pressure, SUS316 2

Special version, TSP-no. to be spec. 9

Colour:

Silver 0

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Float type tank gauge according to wire

float type under low pressure

application (20kPa/0.2bar).

Display position: down.

SPK: NSB

52007810

Float Gauge LTC2240

LTC2240-

Float Gauge LTC2240

Function:

Basic version 0

Special version, TSP-no. to be spec. 9

Process Connection:

10K 150A RF, SS400 flange JIS B2220 0

6" 150lbs RF, SS400 flange ANSI B16.5 1

Special version, TSP-no. to be spec. 9

Measuring Range:

2.5m 1

5m 2

10m 3

Special version, TSP-no. to be spec. 9

Display:

Dial 1 pointer 1

Special version, TSP-no. to be spec. 9

Application:

Gauge head only 000

Standard application 083

Special version, TSP-no. to be spec. 999

Float:

2.1kg, d=140mm (0.5-0.93g/cm3) 1

2.4kg, d=140mm (0.94-2.0g/cm3) 2

Not selected 3

Special version, TSP-no. to be spec. 9

Colour:

Silver 0

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Page 19 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Level switch according to displacer

principle.

SPK: NSD

52007827

Level Switch MPC2000

MPC2-

Level Switch MPC2000

Type:

Not selected 0

Internal pipe 1

External pipe (side-side installation 25A/1") 2

External pipe (side-bottom installation 25A/ 1") 3

Heat Radiation:

w/o fin, max 100oC 0

Double fin, max 250oC 1

Single fin, max 150oC 2

Switch Count:

1x Level 1

2x Level 2

3x Level 3

4x Level 4

1x FRT Overflow detection 5

1x CRT Overflow detection 6

Approval:

Special version, TSP-no. to be spec. 9

Flame proof d2G4, TIIS + cable gland B

Flame proof d2G4, TIIS E

Weather proof IP65 W

Weather proof IP65 + cable connector X

Function:

Basic version 0

Special version, TSP-no. to be spec. 9

Process Connection, Top Mounted Flange:

10K 65A RF, SUS304 flange JIS B2220 3

10K 65A RF, SUS316 flange JIS B2220 4

10K 80A RF, SUS304 flange JIS B2220 1

10K 80A RF, SUS316 flange JIS B2220 2

10K 100A RF, SUS304 flange JIS B2220 S

10K 100A RF, SUS316 flange JIS B2220 T

20K 65A RF, SUS304 flange JIS B2220 7

20K 65A RF, SUS316 flange JIS B2220 8

20K 80A RF, SUS304 flange JIS B2220 5

20K 80A RF, SUS316 flange JIS B2220 6

2-1/2" 150lbs RF, SUS304 flange ANSI B16.5 C

2-1/2" 150lbs RF, SUS316 flange ANSI B16.5 D

2-1/2" 300lbs RF, SUS304 flange ANSI B16.5 G

2-1/2" 300lbs RF, SUS316 flange ANSI B16.5 H

3" 150lbs RF, SUS304 flange ANSI B16.5 A

3" 150lbs RF, SUS316 flange ANSI B16.5 B

3" 300lbs RF, SUS304 flange ANSI B16.5 E

3" 300lbs RF, SUS316 flange ANSI B16.5 F

4" 150lbs RF, SUS304 flange ANSI B16.5 U

4" 150lbs RF, SUS316 flange ANSI B16.5 V

65A 150lbs RF, SUS304 flange JPI 7S-15 L

65A 150lbs RF, SUS316 flange JPI 7S-15 M

65A 300lbs RF, SUS304 flange JPI 7S-15 Q

Page 20 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

65A 300lbs RF, SUS316 flange JPI 7S-15 R

80A 150lbs RF, SUS304 flange JPI 7S-15 J

80A 150lbs RF, SUS316 flange JPI 7S-15 K

80A 300lbs RF, SUS304 flange JPI 7S-15 N

80A 300lbs RF, SUS316 flange JPI 7S-15 P

100A 150lbs RF, SUS304 flange JPI 7S-15 W

100A 150lbs RF, SUS316 flange JPI 7S-15 X

Special version, TSP-no. to be spec. 9

Switch Position:

Lower 0

Lower + upper 1

Upper 2

Pipe:

Not selected 0

xxx mm T, internal pipe, SGP/SS 1

xxx mm T, internal pipe, SUS304 2

xxx mm T, internal pipe, SUS316 3

xxx mm S, external pipe, STPG/SS, S25C 4

xxx mm S, external pipe, SUS304 5

xxx mm S, external pipe, SUS316 6

Special version, TSP-no. to be spec. 9

Set Point:

mm H, flange-SW1 (300-3850mm) A

mm H mm L1 H=flange-SW1 L1=SW1-SW2 B

mm H mm L1 mm L2, H=flange-SW1 L1=SW1-SW2 L2=SW2-SW3 C

mm H mm L1 mm L2 mm L3, H=flange-SW1 L1=SW1-SW2 L2=SW2-SW3, L3=SW3-SW4 D

Special version, TSP-no. to be spec. Y

Cable Entry:

Thread PF(G)3/4 0

Thread PF(G)3/4, TF16-11 1

Thread PF(G)1, TF22-13 2

Thread PF(G)1, TF22-15 3

Thread PF(G)1-1/4, TF28-18 4

Thread NPT3/4 5

Special version, TSP-no. to be spec. 9

Density Range:

Not selected 0

0.65 - 1.2g/cm3, see additional spec. 3

Special version, TSP-no. to be spec. 9

Colour:

Silver 0

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Integrating a radar/servo +

5 other HART sensors into a

Tank Inventory System.

Setup-/diagnostic software

included.

Inputs for spot RTD, analogue 4-20mA

in- and outputs, 2 discrete contact

in-/outputs (solid state).

:: Graphic LC display with backlight.

:: Various industry protocols available.

:: Easy commissioning.

:: Provides intrinsic safe supply

for connected sensors.

SPK: NSE

52011355

Tank Side Monitor NRF590

NRF590-

Tank Side Monitor NRF590

Page 21 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Approval:

Non-hazardous area A

ATEX II 2 (1) EEx d (ia) IIC T6 6

CSA XP Cl.I Div.1 Gr.A-D, zone 1,2 U

FM XP Cl.I Div.1 Gr.A-D, zone 1,2 S

TIIS EEx d (ia) IIC T4 K

Special version, TSP-no. to be spec. Y

Field Communication Protocol Ex d/XP:

ENRAF BPM, 4-20mA input, 4-20mA HART output E

GPE, 4-20mA output, 4-20mA HART output G

Whessoe WM550 (dualer output), 4-20mA output, 4-20mA HART output 1

VAREC Mark/Space, 4-20mA input, 4-20mA HART output 3

Modbus EIA 485 4

Modbus EIA 485, 4-20mA Input, 4-20mA HART output 5

L&J, 4-20mA input, 4-20mA HART output 7

Sakura V1, 4-20mA output, 4-20mA HART output, Relay output 8

Special version, TSP-no. to be spec. 9

Power Supply:

18-55V AC/DC A

55-264VAC B

Special version, TSP-no. to be spec. Y

Spot Rtd Option:

Not selected 0

Intrinsically safe input 1

Special version, TSP-no. to be spec. 9

Digital Module A:

Not selected A

Input 90-140VAC B

Input 3-32VDC C

Input 180-264VAC D

Input 35-60VAC/DC E

Output 24-250VAC G

Output 3-60VDC H

Output 24-140VAC J

Output 4-200VDC K

Relay 0-100VDC, 0-120VAC R

Special version, TSP-no. to be spec. Y

Digital Module B:

Not selected A

Input 90-140VAC B

Input 3-32VDC C

Input 180-264VAC D

Input 35-60VAC/DC E

Output 24-250VAC G

Output 3-60VDC H

Output 24-140VAC J

Output 4-200VDC K

Relay 0-100VDC, 0-120VAC R

Special version, TSP-no. to be spec. Y

Additional Intrinsically Safe Module:

Input 4-20mA + 2x input digital 2

Special version, TSP-no. to be spec. 9

Cable Entry (Non-IS):

2x Ex d gland G1/2 F

2x Ex d thread M20 (Non Ex > gland M20) B

2x Ex d thread G1/2 C

2x Ex d thread NPT1/2 D

2x Ex d thread NPT3/4 E

3x Ex d thread M20 (Non Ex > gland M20) H

3x Ex d thread G1/2 K

3x Ex d thread NPT1/2 L

Special version, TSP-no. to be spec. Y

Page 22 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Entry - IS Compartment:

2x Gland M25, 13-18mm 2

2x Thread G1/2 3

2x Thread NPT1/2 4

2x Thread NPT3/4 5

Special version, TSP-no. to be spec. 9

Weight + Measure Approval:

Not selected N

NMi type approval A

PTB type approval G

Special version, TSP-no. to be spec. Y

Additional Option:

Basic version 0

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

for oil leakage detecting system.

SPK: NSH

52006073

Transmitter NRR262

NRR262-

Transmitter NRR262

Approval:

Ex ia IIB T4, TIIS (NAR300), see additional spec. 2

Special version, TSP-no. to be spec. 9

Power Supply:

90-250VAC 50/60Hz A

22-26VDC B

Special version, to be specified Y

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Advanced technology oil leak

detection for use in depot, refinery,

power plants etc. for environment

protection.

SPK: NSH

56004244

Oil leak detector NAR300

NAR300-

Oil leak detector NAR300

Approval:

Ex ia IIB T4, TIIS 1

Special version, TSP-no. to be spec. 9

Type:

Float 1

Float, module set (Econounce NRR261 upgrade) 2

Float, Ex box (Econounce NRR262 upgrade) 4

Float, Ex box (separate type) 5

Special version, TSP-no. to be spec. 9

Page 23 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Output:

2-wire current A

Special version, TSP-no. to be spec. Y

Signal Cable:

6m A

10m B

15m C

20m D

25m E

30m F

Special version, TSP-no. to be spec. Y

Float Guide:

Not used 1

**Guide 304, weight SS400 2

**Guide 304, weight 304 3

Special version, TSP-no. to be spec. 9

Cable Entry:

Not needed A

G1/2 B

NPT1/2 C

M25 E

Special version, TSP-no. to be spec. Y

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

for oil leakage detecting system.

SPK: NSH

52006072

Transmitter NRR261, Ex d

NRR261-

Transmitter NRR261, Ex d

Approval:

Ex d ia, IIB T4 TIIS (NAR300) 2

TIIS Ex d(ia) IIB T4 (NAR300 separate type) 3

Special version, TSP-no. to be spec. 9

Power Supply:

90-250VAC 50/60Hz A

22-26VDC B

Special version, TSP-no. to be spec. Y

Cable Entry:

G3/4 x2 (Ex d) A

NPT3/4 x2 (Ex d) B

M25 x2 (Ex d) D

G3/4 x2 (Ex d), G1/2 x1 (Ex ia) E

G1/2 x2 (Ex d), G1/2 x1 (Ex ia) K

Special version, TSP-no. to be spec. Y

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Page 24 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Level and temperature indicator

directly connected to the HART input

of Proservo NMS.

Tank side mounted in hazardous area.

Operated via optical keys. SPK: NSI

017405-9000

Promonitor NRF560

NRF560-

Promonitor NRF560

Approval:

Weather proof, IP67 NEMA4X 0

TIIS Ex d IIB T4 X 1

FM XP Cl.I, Div.1, Gr.A-D 4

CSA Cl.I, Div.1, Gr.A-D 5

ATEX II 2G Ex d IIC T4 6

Special version, TSP-no. to be spec. 9

Cable Entry:

2x thread G1/2 A

2x thread NPT1/2 B

2x thread M20 D

Special version, TSP-no. to be spec. Y

Power Supply:

85-264VAC, 50/60Hz 3

20-62VDC, 20-55VAC, 50/60Hz 4

Special version, TSP-no. to be spec. 9

Mounting Bracket:

Not selected 0

Selected 1

Special version, TSP-no. to be spec. 9

Colour:

Blue 0

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

For mechanical tank gauges

LT and LTC series.

SPK: NSK

52007567

Analogue Transmitter AT1000

AT1-

Analogue Transmitter AT1000

Output:

4-20mA 1

10-50mA 2

0-1mA 3

0-20mA 4

0-10mVDC 5

0-1VDC 6

Special version, TSP-no. to be spec. 9

Power Type:

AC 1

DC 2

Alarm Output:

Page 25 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Not used 0

2-point 2

4-point 4

6-point 6

Approval:

Flame proof d2G4, TIIS + cable gland B

Flame proof d2G4, TIIS E

Weather proof IP65 W

Special version, TSP-no. to be spec. Y

Function:

Basic version 0

Special version, TSP-no. to be spec. 9

Power Supply:

100VAC, 50/60Hz 1

110VAC, 50/60Hz 2

200VAC, 50/60Hz 3

220VAC, 50/60Hz 4

24VDC 5

Special version, TSP-no. to be spec. 9

Cable Entry:

1x thread PF(G)3/4 A

2x thread PF(G)3/4 B

1x thread PF(G)1-1/2 C

1x thread PF(G)1-1/2, 1x PF(G)3/4 D

1x gland PF(G)3/4, TF16-11 E

2x gland PF(G)3/4, TF16-11 F

1x gland PF(G)1, TF22-15 G

1x thread M25 K

2x thread NPT3/4 R

Special version, TSP-no. to be spec. Y

Installation Gauge:

LT1100/LT1200/LT3100/LT3200 R:300mm low pressure LT version 1

LT1400/LT1600/LT3400/LT3600 R:300mm high pressure LT version 2

LTC2100 L:600mm 3

LTC2230/LTC2240 R:600mm 4

Special version, TSP-no. to be spec. 9

Measuring Range:

2.5m 1

5m 2

10m 3

16m 4

20m 5

30m 6

Special version, TSP-no. to be spec. 9

Alarm Contact:

Not used 0

A = normal open 1

B = normal closed 2

C = transfer contact 3

Colour:

Silver 0

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Page 26 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

For mechanical tank gauges

LT and LTC series.

SPK: NSK

52007817

Digital Transmitter TMD1 (TMD1000)

TMD1-

Digital Transmitter TMD1 (TMD1000)

Output 1:

Not selected 0

4-20mA 1

2-way 2-wire (MDP protocol) 2

BCD parallel 3

Sakura code parallel 4

2-way 2-wire (MIC, BBB protocol) 5

2-way 2-wire (V1 protocol) 6

Special version, TSP-no. to be spec. 9

Function:

HART input (NMT5xx, NRF560) B

Special version, TSP-no. to be spec. 9

Approval:

Weather proof IP65 0

Flame proof d2G4, TIIS 1

Flame proof d2G4, TIIS + cable gland 2

Output 2:

Not selected 0

4-20mA 1

4x alarm (open collector) 2

Monitor DRM 3

2x gauge operation command 4

2x gauge operation command, 6x outer equipment operation command 5

8x outer equipment operation command 6

4-20mA, 4x alarm (open collector) A

4-20mA, monitor DRM B

4x alarm (open collector), monitor DRM C

4-20mA, 4x alarm (open collector), monitor DRM D

4-20mA, 2x gauge operation command E

2x gauge operation command, monitor DRM F

Special version, TSP-no. to be spec. Y

Input:

Not used 0

4-20mA 1

4x status 2

1x spot temperature Pt100/JPt100 3

3x spot temperature Pt100/JPt100 4

Multi element average temperature 5

Multi spot average temperature 6

4-20mA, 1x spot temperature Pt100/JPt100 A

4-20mA, 3x point spot temperature Pt100/JPt100 B

4-20mA,multi element average temperature C

4-20mA, multi spot average temperature Pt100/JPt100 D

4x status, 1x spot temperature Pt100/JPt100 E

4x status, 3x spot temperature Pt100/JPt100 F

4x status, multi element average temperature G

4x status, multi spot average temperature H

4-20mA, 4x status J

4-20mA, 4x status, 1x spot temperature Pt100/JPt100 K

4-20mA, 4x status, 3x spot temperature Pt100/JPt100 L

4-20mA, multi element average temperature, 4x status M

4-20mA, multi spot average temperature, 4x status N

Page 27 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Special version, TSP-no. to be spec. Y

Power Supply:

60VAC, 50/60Hz 5

100VAC, 50/60Hz 1

110VAC, 50/60Hz 2

200VAC, 50/60Hz 3

220VAC, 50/60Hz 4

Special version, TSP-no. to be spec. 9

Colour:

Blue + white 1

Special version, TSP-no. to be spec. 9

Cable Entry:

A: PF(G)1-1/2, B: PF(G)3/4, C: PF(G)1, D: PF(G)1 0

A: NPT1-1/2, B: NPT3/4, C: NPT1, D: NPT1 1

A: none, C: PF(G)1 TF22-15, B: PF(G)3/4 TF16-11, D: none 2

C: PF(G)1 TF22-15, D: PF(G)1 TF22-15 A: none, B: PF(G)3/4 TF16-11, 3

A: PF(G)1 TF22-15, D: none, B: PF(G)3/4 TF16-11, C: PF(G)1 TF22-15 4

A: PF(G)1 TF22-15, C: PF(G)1 TF22-15, B: PF(G)3/4 TF16-11, D: PF(G)1 TF22-15 5

A: PF(G)1-1/4 TF28-18, D: PF(G)1 TF22-15 B: PF(G)3/4 TF16-11, C: PF(G)1 TF22-15, 7

A: none, B: PF(G)3/4 TF16-11, D: none C: PF(G)1-1/4 TF28-18 A

A: none, B: PF(G)3/4 TF16-11, C: PF(G)1-1/4 TF28-18, D: PF(G)1 TF22-15 B

C: PF(G)1-1/4 TF28-18, D: none, A: PF(G)1 TF22-15, B: PF(G)3/4 TF16-11 C

A: PF(G)1 TF22-15, B: PF(G)3/4 TF16-11, C: PF(G)1-1/4 TF28-18, D: PF(G)1 TF22-15 D

A: PF(G)1-1/4 TF28-18, B: PF(G)3/4 TF16-11, C: PF(G)1-1/4 TF28-18, D: PF(G)1 TF22-15 F

Special version, TSP-no. to be spec. 9

Communication:

Not used 0

2-way 2-wire (MIC, BBB protocol) 2

2-way 2-wire (MDP protocol) 3

2-way 2-wire (V1 protocol) 4

Emitter common A

Collector common B

Special version, TSP-no. to be spec. 9

Temperature Input:

Not used 0

Pt100, JIS=IEC, -50...+200oC 1

Pt100, JIS=IEC, +70...+350oC 2

JPt100, JIS, -50...+200oC 3

JPt100, JIS, +70...+350oC 4

NMT 5

Special version, TSP-no. to be spec. 9

Application:

LT11/LT12/LT31/LT32 3

LT14/LT16/LT34/LT36 4

LTC2230/LTC2240 5

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

For mechanical tank gauges

LT and LTC series.

SPK: NSK

52007816

Analogue Transmitter AT5000

AT500-

Page 28 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Analogue Transmitter AT5000

Alarm Output:

2-point 2

4-point 4

6-point 6

Function:

Basic version 0

Special version, TSP-no. to be spec. 1

Approval:

Flame proof d2G4, cable ground, TIIS B

Flame proof d2G4, TIIS E

Weather proof IP65 W

Special version, TSP-no. to be spec. Y

Level Gauge Combination:

LT1100/LT1200/LT3100/LT3200 R:300mm low pressure LT version 1

LT1400/LT1600/LT3400/LT3600 R:300mm high pressure LT version 2

LTC2100 L:600mm 3

LTC2230/LTC2240 R:600mm 4

Special version, TSP-no. to be spec. 9

Measuring Range:

2.5m 1

5m 2

10m 3

20m 5

30m 6

Special version, TSP-no. to be spec. 9

Alarm Contact:

A = normal open 1

B = normal closed 2

C = transfer contact 3

Cable Entry:

Thread PF(G)3/4 A

Thread PF(G)1-1/2 C

Gland PF(G)1, TF22-13 G

Gland PF(G)1, TF22-15 H

Gland PF(G)1-1/4, TF28-21 K

Thread NPT3/4 R

Thread NPT1 S

Thread M25 T

Special version, TSP-no. to be spec. Y

Colour:

Silver 0

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

SPK: NSS

52013134

Rail mounting kit, housing F22, NRF590

Rail mounting kit, housing F22, NRF590

Page 29 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

For tank gauges field mounted, for tank

gauges. It provides additional switching

of operation contacts of the gauge in

order to control the gauge's operation

(lift up displacer). SPK: NSS

016977-9000

Power + Control Switch NHS8

NHS8-

Power + Control Switch NHS8

Approval:

Weather proof IP67 1

Flame proof (JIS d3aG5) 2

Cable Entry:

2x thread PF(G)3/4 0

2x thread PF(G)1 1

2x thread NPT3/4 2

2x thread NPT1 3

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Used for start up, calibration and

service of the level gauges TGM5

and TMD (in combination with LT1x).

Provides direct access to all parameters

and values stored in the gauge.

Connected to the gauge with an optical

connector included.

SPK: NSS

52007821

Hand Held Terminal HHT2

HHT2-

Hand Held Terminal HHT2

Approval:

Intrinsically safe, i2G3 TIIS E

Cable:

1m 0

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

For tank level gauge;

high pressure version.

Maintenance chamber is recommended

for use with tank level gauges

in order to allow maintenance

(removing displacers),

while tank is in service.

Standard chamber is 6" flange,

with bolts&packing for NMS connection.

SPK: NSS

52004545

Calibration Chamber NHC4HP

NHC4HP-

Calibration Chamber NHC4HP

Process Connection:

10K 150A RF, flange JIS B2220 A

10K 150A FF, flange JIS B2220 C

20K 150A RF, flange JIS B2220 E

6" 150lbs RF, flange ANSI B16.5 G

6" 300lbs RF, flange ANSI B16.5 J

Page 30 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

DN150 PN10 B1, flange EN1092-1 (DIN2527 B) L

DN150 PN25 B1, flange EN1092-1 (DIN2527 B) N

150A 150lbs RF, flange JPI 7S-15 Q

150A 300lbs RF, flange JPI 7S-15 S

Special version, TSP-no. to be spec. Y

Pipe Material; Flange Material:

STPG370; SS400 2

SUS304TP; SUS304 3

Special version, TSP-no. to be spec. 9

Bolts, Packing:

Not used 0

SUS304, Valker #6502 1

Special version, TSP-no. to be spec. 9

Pressure Gauge, Relief Valve:

Selected 1

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

For tank level gauge;

low pressure version.

Maintenance chamber is recommended

for use with tank level gauges

in order to allow maintenance

(removing displacers),

while tank is in service.

Standard chamber is 6" flange,

with bolts&packing for NMS connection.

SPK: NSS

52004544

Calibration Chamber NHC4LP

NHC4LP-

Calibration Chamber NHC4LP

Process Connection:

10K 150A RF, flange JIS B2220 A

10K 150A FF, flange JIS B2220 C

6" 150lbs RF, flange ANSI B16.5 G

DN150 PN10 B1, flange EN1092-1 (DIN2527 B) L

150A 150lbs RF, flange JPI 7S-15 Q

Special version, TSP-no. to be spec. Y

Pipe Material; Flange Material:

AC4A; AC4A 1

SUS304TP; SUS304 3

Special version, TSP-no. to be spec. 9

Bolts, Packing:

Not used 0

SUS304, Valker #6502 1

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

The gauge connection of the reducing

flange is always in the same flange

norm like the process connection, but

with 3" resp. DN80 size.

The reducing flange is equipped with

stud bolts only for the gauge connec-

tion side.

SPK: NSS

017408-9000

Reducing Flange NHF4

NHF4-

Page 31 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Reducing Flange NHF4

Process Connection:

10K 150A RF, flange JIS B2220 A

10K 150A FF, flange JIS B2220 C

20K 150A RF, flange JIS B2220 E

6" 150lbs RF, flange ANSI B16.5 G

6" 300lbs RF, flange ANSI B16.5 J

DN150 PN10 B1, flange EN1092-1 (DIN2527 B) L

DN150 PN25 B1, flange EN1092-1 (DIN2527 B) N

150A 150lbs RF, flange JPI 7S-15 Q

150A 300lbs RF, flange JPI 7S-15 S

Special version, TSP-no. to be spec. Y

Flange Material:

Mild Steel (JIS SS41) 0

SUS304 1

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Standard ball valve with JIS flanges.

For body in mild steel and in SS304,

ball material is SS304. For body in

SS316, ball material is SS316.

Seat material is PTFE. SPK: NSS

017407-9000

Ball Valve NHV4J

NHV4J-

Ball Valve NHV4J

Process Connection; Body:

10K 80A RF; Steel flange JIS B2220 C11

10K 150A RF; Steel flange JIS B2220 C12

20K 80A RF; Steel flange JIS B2220 C21

20K 150A RF; Steel flange JIS B2220 C22

10K 80A RF; SS316 flange JIS B2220 S11

10K 150A RF; SS316 flange JIS B2220 S12

20K 80A RF; SS316 flange JIS B2220 S21

20K 150A RF; SS316 flange JIS B2220 S22

10K 80A RF; SS304 flange JIS B2220 H11

10K 150A RF; SS304 flange JIS B2220 H12

20K 80A RF; SS304 flange JIS B2220 H21

20K 150A RF; SS304 flange JIS B2220 H22

Special version, TSP-no. to be spec. Y99

Ball Type:

Full bore A

Reduced bore B

Special version, TSP-no. to be spec. Y

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Page 32 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Standard ball valve with ANSI flanges.

Ball material is SS304, seat material is

PTFE.

SPK: NSS

017406-9000

Ball Valve NHV4A

NHV4A-

Ball Valve NHV4A

Process Connection; Body:

3" 150lbs RF; Steel casting flange ANSI B16.5 C31

3" 300lbs RF; Steel casting flange ANSI B16.5 C33

6" 150lbs RF; Steel casting flange ANSI B16.5 C61

6" 300lbs RF; Steel casting flange ANSI B16.5 C63

3" 150lbs RF; SS304 flange ANSI B16.5 S31

3" 300lbs RF; SS304 flange ANSI B16.5 S33

6" 150lbs RF; SS304 flange ANSI B16.5 S61

6" 300lbs RF; SS304 flange ANSI B16.5 S63

Special version, TSP-no. to be spec. Y99

Ball Type:

Full bore A

Reduced bore B

Special version, TSP-no. to be spec. Y

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Average temperature converter

for existing temperature sensor

RCV1100/1200

HART output to NMS servo gauge.

SPK: NST

52013913

Temperature Converter RCV-NMT NCT530

NCT530-

Temperature Converter RCV-NMT NCT530

Converter:

Integrated type 6

External type 7

Approval:

Weather proof IP67 0

Ex d IIB T4, TIIS 1

Special version, TSP-no. to be spec. 9

Cable Entry:

Not selected B

2x thread G1/2 A

2x thread G3/4 C

2x thread G1/2, G3/4, integrated type D

1x gland G1/2, integrated type E

1x gland G3/4, integrated type F

Special version, TSP-no. to be spec. Y

Element Type:

Pt100, MRT 1

Pt100, MST 2

JPt100, MRT 3

JPt100, MST 4

Special version, TSP-no. to be spec. 9

Page 33 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Range:

-50...+200oC liquid/gas temp. 1

Special version, TSP-no. to be spec. 9

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Simple temperature measurement for

non-custody transfer application.

Temp. data in HART loop connection

to NRF590/NMS5.

SPK: NST

70104682

Prothermo NMT532

NMT532-

Prothermo NMT532

Approval:

FM IS Cl.I Div.1 Gr.A-D 7

CSA IS Cl.I Div.1 Gr.A-D 8

ATEX Ex ia IIB T4-T6 B

IEC Ex ia IIB T2-T6 Ga F

Cable Entry:

Thread NPT1/2 B

Thread M20 D

Process Connection:

2" 150lbs RF, 304 flange ANSI B16.5 1

DN50 PN10 B1, 304 flange EN1092-1 (DIN2527 C) 2

Special version, TSP-no. to be spec. 9

Probe Length; Element; Interval:

xxx mm; 2x Pt100; 2m 022

xxx mm; 3x Pt100; 2m 032

xxx mm; 4x Pt100; 2m 042

xxx mm; 5x Pt100; 2m 052

xxx mm; 6x Pt100; 2m 062

xxx mm; 2x Pt100; 3m 023

xxx mm; 3x Pt100; 3m 033

xxx mm; 4x Pt100; 3m 043

xxx mm; 5x Pt100; 3m 053

xxx mm; 6x Pt100; 3m 063

Additional Option:

Not selected A

Anchor weight, high profile B

Anchor weight, low profile C

Tension wire, wire hook, NPT1 top anchor D

Tension wire, wire hook, R1 top anchor F

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Precision temperature measurement for

custody transfer application.

Water I/F measurement under oil layer

Both temp. & WB data in single HART loop

Connection to NMS/NRF590. SPK: NST

56004109

Prothermo NMT539

NMT539-

Page 34 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Prothermo NMT539

Approval:

Weather proof, IP65 NEMA4X 0

FM IS Cl.I Div.1 Gr.C-D 7

CSA IS Cl.I Div.1 Gr.C-D 8

ATEX Ex ia IIB T2-T6 B

TIIS Ex ia IIB T2 C

TIIS Ex ia IIB T4 A

TIIS Ex d (ia) IIB T4 E

IEC Ex ia IIB T2-T6 Ga F

Special version, TSP-no. to be spec. 9

Application:

Converter 0

Temperature, converter 1

Temperature, water bottom, converter 3

Temperature, converter, (PTB type approval) 4

Temperature, converter, water bottom, (PTB type approval) 5

Special version, TSP-no. to be spec. 9

Temperature Measuring Range:

Not selected 0

-20...+100oC 5

-40...+100oC 1

-20...+235oC 6

-55...+235oC 2

-170...+60oC 3

-20...+120oC (PTB type approval only) 4

Special version, TSP-no. to be spec. 9

Water Bottom Measuring Range:

Not selected 0

1m/3.3ft 1

2m/6.6ft 2

Special version, TSP-no. to be spec. 9

Cable Entry:

Thread G1/2 A

Thread NPT1/2 B

Thread M20 D

Special version, TSP-no. to be spec. Y

Process Connection:

10K 50A RF, 316 flange JIS B2220 0

2" 150lbs RF, 316 flange ANSI B16.5 1

DN50 PN10 B1, 316 flange EN1092-1 (DIN2527 B) 2

50A 150lbs RF, 316 flange JPI 7S-15 3

Universal coupling, G3/4, (converter only) 4

Thread M20 (converter only) 5

Special version, TSP-no. to be spec. 9

Temperature Element:

2x Pt100 A

3x Pt100 B

4x Pt100 C

5x Pt100 D

6x Pt100 E

7x Pt100 F

8x Pt100 G

9x Pt100 H

10x Pt100 J

11x Pt100 K

12x Pt100 L

13x Pt100 M

14x Pt100 N

15x Pt100 O

16x Pt100 P

Not selected Q

Page 35 / 36

Configurator 2011-2012 Endress+Hauser Consult AG

Kägenstrasse 2

CH - 4153 Reinach

Special version, TSP-no. to be spec. Y

Temperature Element Spacing:

UK standard (converter only) 7

1m / 39" 3

1.5m / 59" 2

2m / 79" 1

3m / 118" 5

Equally spaced, defined by length 4

Not selected 6

Special version, TSP-no. to be spec. 9

Probe Length:

xxx mm A

Not selected B

Special version, TSP-no. to be spec. Y

Mounting Attachment:

Not selected A

Anchor weight, high profile (D120) B

Anchor weight, low profile (hexagon H41) C

Tension wire, wire hook, NPT1 top anchor D

Tension wire, wire hook, R1 top anchor F

Special version, TSP-no. to be spec. Y

>>>Marking: (optional)

Tagging (TAG), see additional spec. 1

Page 36 / 36