16
STORAGE TANKS STORAGE TANKS CATHODIC PROTECTION CATHODIC PROTECTION PREPERED AND PRESENTED PREPERED AND PRESENTED BY BY M.Y.EL SHAZLY M.Y.EL SHAZLY TECOF TECOF

Tank Internal Cathodic Protection

Embed Size (px)

Citation preview

Page 1: Tank Internal Cathodic Protection

STORAGE TANKSSTORAGE TANKSCATHODIC PROTECTIONCATHODIC PROTECTION

PREPERED AND PRESENTEDPREPERED AND PRESENTED

BYBY

M.Y.EL SHAZLYM.Y.EL SHAZLY

TECOTECOFF

Page 2: Tank Internal Cathodic Protection

SACRIFICIAL ANODE SYSTEMSACRIFICIAL ANODE SYSTEMTECOTECOFF

CATHODE

ANODE

CURRENT

CURRENT

Page 3: Tank Internal Cathodic Protection

IMPRESSED CURRENTIMPRESSED CURRENTSYSTEMSYSTEM

TECOTECOFF

CATHODE

ANODE

CURRENT

+-

CURRENT

Page 4: Tank Internal Cathodic Protection

INTERNAL & EXTERNALPROTECTED AREA

INTERNALPROTECTION

EXTERNALPROTECTION

INTERNALPROTECTION

INTERNALPROTECTION

EXTERNAL PROTECTION

INTERNAL PROTECTION

PROTECTED AREA = AREA CONTACTING ELECTROLYTE (SOIL AND OR CONDUCTIVE LIQUID)

TECOTECOFF

Page 5: Tank Internal Cathodic Protection

TANK INTERNAL CATHODIC TANK INTERNAL CATHODIC PROTECTIONPROTECTION

IMPRESSED CURRENT SYSTEMIMPRESSED CURRENT SYSTEM

h 2

h1

Referenceelectrode

AnodeTransformer rectifierautomatic control

AV

000

DC outputvolt/current

Set point

Ref. protectionlevel

Protected area = bottom area + shell wetted area

shell wetted area = II x tank diameter x height

bottom area II x (tank diameter) 2 4

Protection current = protected area x current intencity

TECOF

Page 6: Tank Internal Cathodic Protection

TANK INTERNAL CATHODIC TANK INTERNAL CATHODIC PROTECTIONPROTECTION

SACRIFICIAL ANODE SYSTEMSACRIFICIAL ANODE SYSTEM

h 2

h1Anode

Protected area = bottom area + shell wetted area

shell wetted area = II x tank diameter x height

bottom area II x (tank diameter) 2 4

Protection current = protected area x current intencity

Welded anodes

Suspendedanodes

TECOF

Page 7: Tank Internal Cathodic Protection

STORAGE TANKS EXTERNAL STORAGE TANKS EXTERNAL CATHODIC PROTECTIONCATHODIC PROTECTION

UNDER BASE ANODE INSTALLATIONUNDER BASE ANODE INSTALLATION

RODE ANODE TYPERODE ANODE TYPE

50 cm

-950 mv

-850 mv

Rod anodes

TECOF

Page 8: Tank Internal Cathodic Protection

STORAGE TANKS EXTERNAL STORAGE TANKS EXTERNAL CATHODIC PROTECTIONCATHODIC PROTECTION

•UNDER BASE ANODE TYPEUNDER BASE ANODE TYPE

• INSTALLATIONINSTALLATION

50 cm

-900 mv

-850 mv

RIBBON ANODE

TECOF

Page 9: Tank Internal Cathodic Protection

STORAGE TANKS EXTERNAL STORAGE TANKS EXTERNAL CATHODIC PROTECTIONCATHODIC PROTECTION

•DISTREBUTED ANODE INESTALLATIONDISTREBUTED ANODE INESTALLATION

5 -10 m

5 -1

0 m

Rod anodevertical or horizontal

-850 mv

-850 mv

Min. potential point

TECOFRIM POTENTIAL = 1100 TO 1200 BS STANDERED

OR

ADD 1mv per one foot of tank diameter to the min. protection level (-850 mv)

Page 10: Tank Internal Cathodic Protection

STORAGE TANKS EXTERNAL STORAGE TANKS EXTERNAL CATHODIC PROTECTIONCATHODIC PROTECTION

Deep well groundbed

Tank-1 Tank-2 Tank-3 Tank-4

Tank4

Tank Farm

Tank3

Tank2

Tank7

Tank7

Tank6

Tank5

Tank1

Deep wellGB

DEEP WELL GROUND BED DEEP WELL GROUND BED INESTALLATIONINESTALLATION

TECOF

Page 11: Tank Internal Cathodic Protection

STORAGE TANKS EXTERNAL STORAGE TANKS EXTERNAL CATHODIC PROTECTIONCATHODIC PROTECTION

REMOTE GROUND BED INESTALLATIONREMOTE GROUND BED INESTALLATION

TECOF

Tank3

Tank2

Tank1

Tank6

Tank5

Tank4

Tank9

Tank8

Tank7 REMOTE GB

TANK FARM

-450 mv

-850 mv

-2500 mv

Remote GB

Page 12: Tank Internal Cathodic Protection

CURRENT REQUIREMENTCURRENT REQUIREMENT

11 - - SURFACE AREA TO BE SURFACE AREA TO BE PROTECTEDPROTECTED

•EXTERNAL = BOTTOM AREA (BARE)EXTERNAL = BOTTOM AREA (BARE)

INTERNAL = BASE AREA + WETTED SHELL AREA INTERNAL = BASE AREA + WETTED SHELL AREA (BARE)(BARE)

IF COATED A COATING DEFFECT PERCENTAGE MUST BE APPLAYEDIF COATED A COATING DEFFECT PERCENTAGE MUST BE APPLAYEDTECOF

Page 13: Tank Internal Cathodic Protection

CURRENT REQUIREMENTCURRENT REQUIREMENT

22 – – CURRENT INTENSITYCURRENT INTENSITY

INTERNALINTERNAL::

FRESH WATER = 20 ma/m2FRESH WATER = 20 ma/m2

SALT WATER = 100 ma/m2SALT WATER = 100 ma/m2

EXTERNALEXTERNAL::

DEPEND ON SOIL RESISTIVITYDEPEND ON SOIL RESISTIVITY

RANGES FROM 5 TO 0.5 ma/m2RANGES FROM 5 TO 0.5 ma/m2TECOF

Page 14: Tank Internal Cathodic Protection

CURRENT REQUIREMENTCURRENT REQUIREMENT

33 – – CURRENT CALCULATIONCURRENT CALCULATION= = SURFACE AREA TO BE PROTECTED X CURRENT SURFACE AREA TO BE PROTECTED X CURRENT INTENCITYINTENCITY

11 - -COATING DEFFECT PERCENTAGE TO BE TAKEN INTO COATING DEFFECT PERCENTAGE TO BE TAKEN INTO CONSEDIRATIONCONSEDIRATION

22 - -IF THE TANK IS USED TO STORE WATER, THIS MEENSIF THE TANK IS USED TO STORE WATER, THIS MEENS

THAT SHELL WETTED AREA WILL CHANGE WITH THAT SHELL WETTED AREA WILL CHANGE WITH HIGHT, . HEIGHER CURRENT VALUE MUST BE HIGHT, . HEIGHER CURRENT VALUE MUST BE TAKEN IN SIZINGTAKEN IN SIZING

TECOF

Page 15: Tank Internal Cathodic Protection

ELECTRICAL EQUIVALENT ELECTRICAL EQUIVALENT CIRCUITCIRCUIT

R2 R1

R3 R4

VOUTPUT

CURRENT

CURRENT = VOLTAGE DIVIDED BY RESISTANCEOHMS LOW

EQUIVALENT CIRCUIT RESISTANCE = R1+R2+R3+R4WHERE:

R1 = NEGATIVE CABLE RESISTANCE ohmR2 = TANK STEEL RESISTANCE ohmR3 = GROUND BED RESISTANCE ohmR4 = POSITIVE CABLE RESISTANCE ohm

CURRENT = PROTECTION CURRENT DEMAND in ampereVOLTAGE = DRIVING POTENTIAL in volt

TECOF

Page 16: Tank Internal Cathodic Protection

SAMPLES OF TANK SAMPLES OF TANK CORROSION CELLSCORROSION CELLS

+

-

+-

+ --

OLD METAL

NEW METAL

OLD METAL

+-

BATCH CORROSIONWELD CORROSION

CP current

Tank bottom

Concrete ringbeam

RING BEAM CORROSION

CORROSIONAREA

DEBARY

CORROSIONPRODUCTS

5 deg.

Bottom plates

ANNUAL PLAT WELD CORROSION