4 strokes Diesel engine, direct injection Power definition Standard ISO 3046/1 - 1995 (F) Reference conditions Ambiant tempeature 25 °C / 77 ° F Barometric pressure 100 kPa Relative humidity 30 % Raw water temperature 25 °C / 77 ° F Fuel oil Relative density 0,840 ± 0,005 Lower calorific power 42 700 kJ/kg Consumption tolerances ± 5 % Air inlet limit de temperature 35 °C / 95 °F Electrical power Power in kVA declared at pf 0.8 Réf. IC 07/A LD SC - 01-2012 Marine Diesel Generators Not contractual picture GENERAL DA T A Models Nb cyl Arrangement Bore (mm) Stroke (mm) Swept vol. (l) Flywheel housing 4 W105S 4 6 6 6 8 12 in line in line in line in line in V in V 105 130 130 155 150 150 150 105 126 150 150 150 4.50 SAE 3 6.75 SAE 3 11.56 SAE 1 15.90 SMB 21.20 SAE 0 31.80 SAE 0 6 W105S 6 W126S 6 M26.2 8 M26.2 12 M26.2 MAXIMUM RA TING T ABLE COP PRP LTP 4 W105S 6 W105S 6 W126S 6 M26.2 8 M26.2 12 M26.2 50 Hz 68 85 kWe kVA kWe kVA kWe kVA 68 85 76 95 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 84 120 132 264 280 304 344 400 464 613 700 105 150 165 330 350 380 430 500 580 765 875 84 120 132 264 280 336 344 440 464 676 700 105 92 115 150 132 165 165 148 185 330 300 375 350 308 385 420 368 460 430 380 475 550 488 610 580 512 640 845 740 925 875 772 965 Continuous power (COP) Rated load without time or load factor limitation Prime running power (PRP) Variable load with mean power calculated on 250 running hours No restriction on use if mean power 75% of nominal power Total operating time at 100% nominal power shall not exceed 500 hours per year 10% overload available 1 hour each 12 hours Limited time running power (LTP) Variable load with mean power calculated on 250 running hours No overload Typical hours per year 500 hours (with mean power 85% of rated power) Total operating time at 100% rated power shall not exceed 25 hours per year Maximum continuous running time at 100% rated power: 1 hour each 12 hours

Talleres Ancora | Talleres Ancora - Marine Diesel Generators · 2013. 2. 13. · 344 400 464 613 700 105 150 165 330 350 380 430 500 580 765 875 84 120 132 264 280 336 344 440 464

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • 4 strokes Diesel engine, direct injection

    Power definitionStandard ISO 3046/1 - 1995 (F)

    Reference conditionsAmbiant tempeature 25 °C / 77 ° F

    Barometric pressure 100 kPa

    Relative humidity 30 %

    Raw water temperature 25 °C / 77 ° F

    Fuel oilRelative density 0,840 ± 0,005

    Lower calorific power 42 700 kJ/kg

    Consumption tolerances ± 5 %

    Air inlet limit de temperature 35 °C / 95 °F

    Electrical powerPower in kVA declared at pf 0.8

    Réf. IC 07/A

    LD SC - 01-2012

    Marine Diesel Generators

    Not contractual picture

    GENERAL DATA

    Models Nb cyl Arrangement Bore (mm) Stroke (mm) Swept vol. (l) Flywheel housing

    4 W105S 4

    6

    6

    6

    8

    12

    in line

    in line

    in line

    in line

    in V

    in V

    105 130

    130

    155

    150

    150

    150

    105

    126

    150

    150

    150

    4.50 SAE 3

    6.75 SAE 3

    11.56 SAE 1

    15.90 SMB

    21.20 SAE 0

    31.80 SAE 0

    6 W105S

    6 W126S

    6 M26.2

    8 M26.2

    12 M26.2

    MAXIMUM RATING TABLE

    COP PRP LTP

    4 W105S

    6 W105S

    6 W126S

    6 M26.2

    8 M26.2

    12 M26.2

    50 Hz 68 85

    kWe kVA kWe kVA kWe kVA

    68 85 76 95

    60 Hz

    50 Hz

    60 Hz

    50 Hz

    60 Hz

    50 Hz

    60 Hz

    50 Hz

    60 Hz

    50 Hz

    60 Hz

    84

    120

    132

    264

    280

    304

    344

    400

    464

    613

    700

    105

    150

    165

    330

    350

    380

    430

    500

    580

    765

    875

    84

    120

    132

    264

    280

    336

    344

    440

    464

    676

    700

    105 92 115

    150 132 165

    165 148 185

    330 300 375

    350 308 385

    420 368 460

    430 380 475

    550 488 610

    580 512 640

    845 740 925

    875 772 965

    Continuous power (COP)

    Rated load without time or load

    factor limitation

    Prime running power (PRP)

    Variable load with mean power calculated on

    250 running hours

    No restriction on use if mean power 75% of

    nominal power

    Total operating time at 100% nominal power

    shall not exceed 500 hours per year

    10% overload available 1 hour each 12 hours

    Limited time running power (LTP)

    Variable load with mean power calculated on

    250 running hours

    No overload

    Typical hours per year 500 hours (with mean

    power 85% of rated power)

    Total operating time at 100% rated power shall

    not exceed 25 hours per year

    Maximum continuous running time at 100%

    rated power: 1 hour each 12 hours

  • Mo

    teu

    rs B

    au

    do

    uin

    re

    se

    rve

    th

    e r

    igh

    t to

    mo

    dify t

    he

    se

    sp

    ecific

    atio

    ns,

    with

    ou

    t n

    otice

    . D

    ocu

    me

    nt

    no

    t co

    ntr

    actu

    al.

    DIMENSIONS

    3 PHASES SYNCHRONOUS GENERATOR

    Frequency 50/60 Hz

    Number of poles 4

    Insulation class H

    Temperature rise class H

    Voltage régulator electronic

    Filter radio frequency interference

    Excitation brushless

    non permanent magnet

    Protection IP23

    Bearing sealed, life lubricated

    Impregnation Marine

    KgBkVA

    4 W105S 85 1 680 1 060 1 270 1 100

    100 2 000 1 016 1 216 1 400

    195 2 586 1 178 1619 2 145

    270

    300 2 686 1303 1619 2 145

    330

    A C

    6 W105S

    6 W126S

    150 2 187 1 016 1 216 1 500

    OPTIONAL EQUIPMENTS (extract)

    Cooling by keel cooling

    High efficiency air filter

    Exhaust silencer

    Water injection type exhaust elbow

    Remote control panel

    Société Internationale des Moteurs Baudouin

    Technoparc du Brégadan - CS 50001 - 13711 Cassis Cedex - France - tél. +33 488 688 500 - fax +33 488 588 501 - www.moteurs-baudouin.com

    KgBkVA

    6 M26.2 420 3 043 1 164 1 414 3 550

    8 M26.2 550 2 996 1 482 1 575 4 580

    12 M26.2 845 3 878 1 456 1 575 6 130

    A C

    6 M26.2

    8 M26.2

    12 M26.2

    4 W105S

    6 W105S

    6 W126S

    A

    A

    A A

    A

    B

    B

    B B

    B

    C

    C

    C C

    C

    A B

    C