TAKING LIGHTING TO HEART
Streetlights and Security Lights
Autobahn Family
Replaces 70 – 200 W Cobraheads2,300 – 11,000 Lumens14 Lbs
Replaces 200 – 400 W Cobraheads7,000 – 23,000 Lumens21 Lbs
2K
23K
9K
ATB0
ATB2
Lumens
ATBSReplaces 70 – 150 W Cobraheads and Area Lights1,700 – 9,700 Lumens12 Lbs
11K
ATBS: Electrical & MechanicalField-adjustableOutput
Acuity Surge ProtectionANCI cat. C rated - 10kV/5kA Utility-friendly
Terminal Block
2-Bolt MountingClamp for 3GVibration Rating
InternalBubbleLevel
IP66 Rated Driver
Cast-inStep leveling
Supplemental transient voltage suppressor
Optical Summary:•Optical equivalent up to 40W HPS/MH
•Up to 24900 Total Lumens
•Multiple Lumen Packages available
•Prismatic: Type II, III & V distributions
•Rain Panel: Type II, III & V distributions
•4K CCT available – crisp white light
LED Performance
TAKING LIGHTING TO HEART
LED – Before and After
• 3-5 Year Life • 15-20 Year Life
5
Product Overview• IP66• Superdurable paint, 2500 hours Salt Fog rating• 2G vibration rated• Knuckle mount• Yoke mount- painted or galvanized• Terminal block standard• PEC receptacle standard• RoamVue optional• Bolted door or latched option• Wire guard, vandal guard options• Visor• Upper/bottom visor
ACP LED Family
Replaces 100 – 400 W Floods5,462 – 23,072 Lumens
Replaces 400 – 1000 W Floods18,482 – 33,060 Lumens
5K
33K
23K
ACP Medium
ACP Large
Lumens
18K
Product Overview: ElectricalLineman Friendly Terminal Block
State-of-the-Art Drivers ( 700mA, 1000mA)
Surge ProtectionANCI cat. C rated - 10kV/5kA
Quick Disconnect for Driver Power Output
Quick Disconnect for Driver Power Input
Product Overview: Optical
ACP Large• 7,8,9 COB modules• 4000KCCT, 70 CRI• 5000K CCT, 70 CRI• 6X5, 6X6 distributions
ACP Medium• 2, 3, 4, 5, 6 COB modules • 4000KCCT, 70 CRI• 5000K CCT, 70 CRI• 5X5, 6X5, 6X6 distributions
Durable Glass Lens• Durability & protection of LEDs
Internal Optics• State-of-the-art COB LEDs (Chip-on-Board)• Highly specular internal reflectors• Multiple lumen packages
TAKING LIGHTING TO HEART
Questions?
Industrial Lighting - What matters most
Industrial customer concerns:
Save moneyEnergy savingsMaintenance savings
I need more light where I need itThis is key
More light = better productivity and safety
Agenda
• How do we perceive light: CRI - Kelvin• Existing technology review• LED
– What it is– How to compare– What is important in a fixture
What is CRI and Kelvin temperature
Kelvin Temperature: what comes out. Warm vs cool light
Eye sees better in blue light
CRI: what we see Range 0-100
Measures intensity at specific wavelengths
Based on incandescent Imperfect scale
Existing In your facilities
• Fluorescent– Instant on, hard to dim, lamps 4-6 years, lumen depreciation
• HID– Long warm up, high LPW, MH 24,000 life, HPS yellow
• Solid State: LED– Instant on, high LPW, easy to dim, OCC, minimal maintenance
LED
Components of an LED fixture• LED : Light Emitting Diode --- Lamp• Driver --- ballast• Surge Protector --- drivers are not as robust as magnetic
ballasts. – Helps suppress transients (not the same as a fuse)
• Optic – still very important• Housing – LED fixtures still need a housing
How to compare LED for IndustrialWhat matters most
• Lumen output
• Watts consumed
• Energy efficiency (lumens per watt)
How to compare LED for IndustrialWhat matters most
LIFE – LED is a whole new ball game. This is NOT HID
– When will the lights go out?? With LED they don’t go out (unless there is a problem)
– Driver life 100,000 hours
– Optic life- so long may need cleaning before replaced
Lamp Mortality – all traditional sources
70%
100%
L70 (hrs)
light
out
put
Time
Threshold
T = 25C
Hotter
Cooler
Required Lighting
Lumen Maintenance curves define LED life. And this varies with temperature.
LED Lamp Lumen Depreciation LLDL70
Light Loss Factors and LEDWill it pass the test of time?
• LED Light Loss Factors LLF– LLD: Lamp Lumen Depreciation (LED L70 / TM21)– LDD: Luminaire Dirt Depreciation– BF/DF: Ballast Factor (LED Driver Factor DF = 1)– TF: Thermal Factor (** BIG DEAL IF HOT)
Used to predict long term performance
Traditional: Lumens Out = Lamp rated lumens * LLD * LDD * BF * TFLED: Lumens Out = Initial Lumens* TM21 * LDD * DF * TF
Fixture efficiency• Get the lumens OUT!
• Typical office – 75-92%• Typical highbay – 55-85%• Typical cobra head – 50-80%
TraditionalLED
Optics – Life and PerformanceCustomer: “I want an LED that will last 100,000 hours.”Lets use an optic that will too.
What optics affect: Maintenance – does it get brown, cloudy or brittle?
Lumen output and efficiency – careful with frosted lenses
Glare - Prisms / Frost / Flat glassDoes it matter if it’s glary?
Distribution – where is light going?I can see the thing I am trying to look at. YAY!!
Distribution PatternsLight where you want it
This is the exact same lumen fixture
Which is which?
• reflector, symmetric• refractor, symmetric• reflector, asymmetric
Get a fixture that fits your spaceC
B
A
Handling Temperature in the Luminaire
Convection (over 80%)
INSIDE FIXTURE
Conduction
Radiation (under 20%)
AMBIENT AIR
LED
AMBIENT AIR
Vertical vs. Horizontal Footcandles
What LED has to offer
• Benefits– Provide strong down light – great for high mounting heights – check
optics– Can be great for ‘hot’ or cold applications – check temp ratings – Can be a small surface area so it works well in dirty environments– Instant ON – no warm up needed to hit full bright. – Dimmable to 10% - additional energy savings– Long Life – 100,000+ hour lamp life / 100,000 hour driver life– Can have good lumen maintenance – maintains high lumen output over
the life of the LEDs (TM21)