2
Available fully covered to provide resistance to migration and over- growth* Proven feasibility of endscopic retrieval* Low axial force and high radial strength for enhanced patient comfort Smooth ends designed to reduce the risk of perforation Low Prole Catheter Low prole delivery catheter for easy operation Our propriety round ends have been designed to reduce the risk of perforation OLD NEW Wire Silicone membrane prevents tissue ingrowth Retrieval string allows repositioning and retrieval Smooth angle Radiopaque markers - clearly visible on uoroscope Features Low Profile Delivery Catheter Esophageal Stent Specialty Endoscopic Products 200 Grandview Avenue Camp Hill, PA 17011 800.451.5797 717.761.0216 fax [email protected] gi-supply.com *Reference paper on the back

Taewoong Niti-S Esophageal Stent from GI Supply

Embed Size (px)

Citation preview

Page 1: Taewoong Niti-S Esophageal Stent from GI Supply

� Available fully coveredto provide resistanceto migration and over-growth*

� Proven feasibility ofendscopic retrieval*

� Low axial force andhigh radial strength forenhanced patientcomfort

� Smooth ends designedto reduce the risk ofperforation

Low Pro�le CatheterLow pro�le delivery catheter for easy operation

Our propriety round endshave been designed to reducethe risk of perforation

OLD NEWWire

Silicone membraneprevents tissue ingrowth

Retrieval string allowsrepositioning and retrieval

Smooth angle

Radiopaque markers - clearly visible on !uoroscopeFeatures

Low Profile Delivery Catheter

Esophageal StentSp

ecia

lty

End

osc

op

ic P

rod

uct

s

200 Grandview AvenueCamp Hill, PA 17011

800.451.5797717.761.0216 fax

[email protected]

*Reference paper on the back

Page 2: Taewoong Niti-S Esophageal Stent from GI Supply

Ordering Information

200 Grandview AvenueCamp Hill, PA 17011Toll Free: 800.451.5797Fax: 717.761.0216 Email: [email protected]: gi-supply.com

© 2015 GI Supply. All rights reserved.G-1202-02

Clinical ReferenceSung Jun Choi, Jin Hong Kim MD. Fully covered, retrievable self-expandingmetal stents (Niti-S) in palliation of malignantdysphagia: Long-term results of a prospectivestudy. Scandinavian Journal of Gastroenterology, 2011; 46: 875-880

Part No.Stent

Diameter(A)

InStock*

OverallStent Length

(C)Profile(Fr)

UsableLength

Introducer System

G-ES1606F

G-ES1608F

G-ES1610F

G-ES1612F

G-ES1615F

G-ES1806F

G-ES1808F

G-ES1810F

G-ES1812F

G-ES1815F

G-ES2006F

G-ES2008F

G-ES2010F

G-ES2012F

G-ES2015F

16 mm

16 mm

16 mm

16 mm

16 mm

18 mm

18 mm

18 mm

18 mm

18 mm

20 mm

20 mm

20 mm

20 mm

20 mm

Stent FlangeDiameter

(B)

24 mm

24 mm

24 mm

24 mm

24 mm

26 mm

26 mm

26 mm

26 mm

26 mm

28 mm

28 mm

28 mm

28 mm

28 mm

60 mm

80 mm

100 mm

120 mm

150 mm

60 mm

80 mm

100 mm

120 mm

150 mm

60 mm

80 mm

100 mm

120 mm

150 mm

FunctionalStent Length

(D)

30 mm

50 mm

70 mm

90 mm

120 mm

30 mm

50 mm

70 mm

90 mm

120 mm

30 mm

50 mm

70 mm

90 mm

120 mm

16

16

16

16

16

16

16

16

16

16

20

20

20

20

20

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

Esophageal Fully Covered Stent

Part No.Stent

Diameter(A)

OverallStent Length

(C)Profile(Fr)

UsableLength

Introducer System

G-ES1606B

G-ES1608B

G-ES1610B

G-ES1612B

G-ES1615B

G-ES1806B

G-ES1808B

G-ES1810B

G-ES1812B

G-ES1815B

G-ES2006B

G-ES2008B

G-ES2010B

G-ES2012B

G-ES2015B

16 mm

16 mm

16 mm

16 mm

16 mm

18 mm

18 mm

18 mm

18 mm

18 mm

20 mm

20 mm

20 mm

20 mm

20 mm

Stent FlangeDiameter

(B)

24 mm

24 mm

24 mm

24 mm

24 mm

26 mm

26 mm

26 mm

26 mm

26 mm

28 mm

28 mm

28 mm

28 mm

28 mm

60 mm

80 mm

100 mm

120 mm

150 mm

60 mm

80 mm

100 mm

120 mm

150 mm

60 mm

80 mm

100 mm

120 mm

150 mm

FunctionalStent Length

(D)

30 mm

50 mm

70 mm

90 mm

120 mm

30 mm

50 mm

70 mm

90 mm

120 mm

30 mm

50 mm

70 mm

90 mm

120 mm

16

16

16

16

16

16

16

16

16

16

20

20

20

20

20

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

70 cm

Esophageal Partially Covered Stent

Length(C)

Functionallength

(D)

Diameter(A)

FlangeDiameter

(B)

An ISO 13485 Certified Company

InStock*

*In stock and ready to ship. Please allow up to 6 weeks delivery for all other stents.

GI Supply has partneredwith Taewoong Medical,a pioneer and leader instent design, to bring youthe Niti-S™ Biliary andEsophageal stents.