Table of Contents

Patch CordArmored and Mode-conditioning Patch CordFTTA and FTTH Drop Patch cordMPO/MTP/LC/SC Loopback Patch cordPigtail and Breakout patch cords

............................................................................... 14................................................................................................. 15

........................................................................................ 16................................................................................................. 17

ConnectorLCSC FC /ST/DIN/SMAMU/LSH/E2000MTP/MTRJ/MPOFerrules

............................................................................................................................................ 8

............................................................................................................................................ 9....................................................................................................................... 10........................................................................................................................ 11....................................................................................................................... 12

.................................................................................................................................. 13

OthersFTTH Box & Field Assembly Optical Connector .............................................................................. 40

PLC250µm bare fiberAdaptor-input ABS type Splitter LGX box PLC Splitter 4/ 6/ 8-1x2 PLC Splitter Device Compact size Mini moduleRack Type PLC Splitter Plug-in Type PLC Splitter1x2 SM FBT/ ABS Type SM FBTPLC Splitter Mini Fan-out

........................................................................................................................ 19..................................................................................................... 20

.................................................................................................................. 21.................................................................................................. 22

......................................................................................................... 23............................................................................................................... 24............................................................................................................ 25

.................................................................................................. 26........................................................................................................... 27

WDM3-port WDM8ch CWDM/DWDM ABS Module CCWDM/LANWDM Module CWDM/DWDM ModuleCWDM/DWDM insert-box module CWDM/DWDM/FWDM LGX module 19" Rack and GPON ModulePLC+WDM Module and 6-port CWDM/DWDM

....................................................................................................................... 28~29................................................................................................. 30

......................................................................................................... 31.............................................................................................................. 32

............................................................................................... 33............................................................................................. 34

...................................................................................................... 35.............................................................................. 36

Data Center SolutionsModule and ODFMini and AOC patch cordMPO/MTP patch cord

..................................................................................................................... 37......................................................................................................... 38

.............................................................................................................. 39

AttenuatorLC/SC/FC/ST/MU ....................................................................................................................... 18

AdapterLC SC FC /ST/DIN/SMA MU/LSH/E2000 MPO/MTP Bare Fiber Hybrid

............................................................................................................................................ 1

............................................................................................................................................ 2....................................................................................................................... 3........................................................................................................................ 4

................................................................................................................................ 5

................................................................................................................................ 6..................................................................................................................................... 7

Page 3: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

FEATURE

PERFORMACE

SPECIFICATIONS

▪Panel clip for easy installation▪Available in several standard colors▪Available without flanges or with flange, saving panel space▪All parts compliant with ROHS▪Compliant with Telcordia and IEC

Items Insertion Loss Mechanical resistance Repeatability Operating Temperature

SM/PC ≤0.2dB

≤0.2dB

≤0.2dB

200-600g

200-600g

200-600g

<0.2dB(1000times)

<0.2dB(1000times)

<0.2dB(1000times)

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

SM/APC

MM/PC

Mold Housing Type Spring Color Flange Shutter

SM Plastic Simplex Metal (Normal) Blue Full Flange Inner

MM Metal Duplex Metal (Stable) Beige With Flange Outer

Quad Plastic Green Without Flange

Aqua

LC Quad Outer Shutter Adapter

LC Quad One-Piece Adapter LC Quad Internal Shutter Adapter

LC Duplex Flanged Adapter LC Duplex One-Piece Adapter

LC Duplex Internal Shutter Adapter LC Quad Compact Adapter

LC Quad Flanged Adapter

LC Duplex RJ45 Adapter

LC Simplex RJ45 Adapter

LC Duplex Compact Adapter

NEW

NEW NEWNEW

Adapter—LC

11

Page 4: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

Adapter—SC

PERFORMACE

SPECIFICATIONS

FEATURE

▪Panel clip for easy installation▪Available in several standard colors▪Available without flanges or with flange for duplex, saving panel space▪All parts compliant with ROHS

Items Insertion Loss Mechanical resistance Repeatability Operating Temperature

SM/PC ≤0.2dB

≤0.2dB

≤0.2dB

200-600g

200-600g

200-600g

<0.2dB(1000times)

<0.2dB(1000times)

<0.2dB(1000times)

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

SM/APC

MM/PC

Mold Housing Type Spring Color F lange Shut ter

SM Metal Simplex Metal Blue With Flange Inner

MM Plastic Duplex Plastic Beige Without Flange Outer

Green

Aqua

SC Simplex Metal Flanged Adapter

SC Duplex Outer Shutter Adapter SC Simplex Internal Shutter Adapter SC Duplex Compact Adapter

SC Simplex Upper Shutter Adapter

SC Simplex Flanged Adapter

SC Simplex Side Shutter Adapter

SC Simplex Side Shutter Adapter

2

SC Duplex Metal Flanged Adapter

Page 5: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

Adapter—FC /ST/DIN/SMA

FEATURE

▪High precision of mechanical dimensions▪High reliability & stability▪Ceramic or Bronze Sleeve▪PC, APC, UPC optional▪All parts compliant with ROHS▪Compliant with Telcordia and IEC

FC SPECIFICATIONS

ST SPECIFICATIONS

Mold Type Housing Body shape Flange shape Dust cap color

SM Simplex Metal One Piece D type Green

MM Duplex Two Piece Double D type Red

Diamond White

Mold Type Housing Body shape Dust cap color

SM Simplex Metal One Piece Red

MM Duplex Two Piece Black

Yellow

Items Insertion Loss Mechanical resistance Repeatability Operating Temperature

SM/PC ≤0.2dB

≤0.2dB

≤0.2dB

100-300g

100-300g

100-300g

<0.2dB(1000times)

<0.2dB(1000times)

<0.2dB(1000times)

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

SM/APC

MM/PC

FC D-Type Adapter FC Square-Type Adapter FC Oval-Type Adapter

FC Rectangle-Type Adapter

ST Simplex Adapter

DIN Adapter

SMA Adapter

3

PERFORMACE

Page 6: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

Adapter—MU/LSH/E2000

LSH & E2000 PERFORMACE

FEATURE

▪High precision of mechanical dimensions▪High reliability & stability▪Ceramic or Bronze Sleeve▪All parts compliant with ROHS▪Compliant with Telcordia and IEC

Items Insertion Loss Mechanical resistance Repeatability Operating Temperature

SM/PC ≤0.2dB

≤0.2dB

≤0.2dB

200-600g

200-600g

200-600g

<0.2dB(1000times)

<0.2dB(1000times)

<0.2dB(1000times)

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

SM/APC

MM/PC

MU PERFORMACE

Items Insertion Loss Mechanical resistance Repeatability Operating Temperature

SM/PC ≤0.2dB

≤0.2dB

≤0.2dB

100-300g

100-300g

100-300g

<0.2dB(1000times)

<0.2dB(1000times)

<0.2dB(1000times)

-40℃~+85℃

-40℃~+85℃

-40℃~+85℃

SM/APC

MM/PC

MU Duplex Adapter

MU Simplex Adapter

LSH Adapter

LSH Metal Flanged Adapter

E - 2000 Metal Flanged Adapter

4

Page 7: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

Adapter—MPO/MTP

FEATURE

SPECIFICATIONS

▪Panel clip for easy installation▪Available in several standard colors▪Available without flanges or with flange ▪All parts compliant with ROHS▪1000 times Repeatability

MTRJ Adapter, black plastic housing.SC Footprint. An adapter is a mechanical device designed to align fiber-optic connectors.MTP/MPO adapter has two types as key-up to key-down and key-up to key-up. It provides the connection between cable to cable or cable to equipment in the MTP/MPO style. It works for any MTP Connector from 4 fiber to 72 fiber, widely used in trunk cabling and casettes. This adapter meets appropriate standards and is perfect for your parallel optics and MTP adapter needs.

MTP Standard Flanged Adapter

MPO SC footprint Adapter

MPO SC footprint Flanged Adapter

MTP SC footprint Adapter

5

Mold Type Housing Body shape Body color

SM Simplex Standard One Piece Black

MM Duplex SC footprint Two Piece Beige

45℃ Angled Aqua

…… Red

……

Page 8: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

Adapter—Bare fiber

BARE FIBER ADAPTER PERFORMACE

FEATURE

▪High precision of mechanical dimensions▪High reliability & stability▪Ceramic or Bronze Sleeve▪PC, APC, UPC optional▪All parts compliant with ROHS▪Compliant with Telcordia and IEC

Optical adapter are developed to couple and mate two identical or two different (hybrid) connector plugs. The housing of the adapters of the last generation has a reference key for the right position coupling and zirconia or phosphorus bronze split sleeve for high alignment.

FC Bare Fiber Adapter

6

Items FC/PC SC/PC ST/PC LC/PC

Ferrule ID 125-127um

Ferrule OD 2.499mm 1.249mm

Insertion loss <0.2dB

Repeatability <0.2dB

Tensile force 100g

Plug times >1000times

Operation temperature -40℃~85℃

Fiber Type OS2/OM1/OM2/OM3/OM4

Page 9: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

Adapter—Hybrid

PERFORMACE

FEATURE

▪High precision of mechanical dimensions▪High reliability & stability▪Ceramic or Bronze Sleeve▪PC, APC, UPC optional▪All parts compliant with ROHS▪Compliant with Telcordia and IEC

MU - FC Hybrid Adapter

FC - SC Hybrid Adapter

LC - FC Hybrid Adapter

LC - SC Hybrid Metal Adapter

ST - SC Hybrid Metal Adapter

Hybrid LC adapter to FC Connector Hybrid FC adapter to ST Connector

7

MU-SC Hybrid Adapter

Items Insertion Loss Mechanical resistance Repeatability Operating Temperature

SM/PC ≤0.2dB

≤0.2dB

≤0.2dB

200-600g

200-600g

200-600g

<0.2dB(1000times)

<0.2dB(1000times)

<0.2dB(1000times)

-40℃~+80℃

-40℃~+80℃

-40℃~+80℃

SM/APC

MM/PC

Page 10: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

8

Connector—LC

LC Simplex 3.0mm ConnectorLC Simplex 0.9mm Connector LC Simplex 2.0mm Connector

LC Duplex 2.0mm Connector

LC Push - Pull Uniboot Connector

LC Uniboot Connector

NEW

NEW

SPECIFICATIONS

FEATURE

▪Low insertion loss▪High return loss▪Easy of installation▪Low cost▪Reliability▪Low environmental sensitivity▪IEC standard compliance;▪ Various housing and boot color for option;

Mold Type Cable Housing color Boot Color

SM Simplex 0.9 Green Green

MM Duplex

Uniboot

Push-Pull

1.2 Blue Blue

1.6 Beige Beige

2.0 Red Red

2.4 White

3.0

PERFORMACE

Items Single mode Multi mode

Insertion Loss ≤0.3dB ≤0.3dB

≥30dBReturn Loss ≥50dB(UPC); ≥60dB(APC)

Ceramic ferrule spec 125.5um concentricity deviations:<1um 127um concentricity deviations:<3um

Insert-pull test 1000 times<0.3dB

Operation temperature -40℃~+85℃

Suitable fiber PC/APC(9/125um) PC(50/125um,62.5/125um)

Page 11: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

9

Connector—SC

SC Duplex 2.0/3.0mm Connector

SC Simplex 2.0/3.0mm Connector

SC Simplex 0.9mm Connector

PERFORMACE

SPECIFICATIONS

FEATURE

▪Low insertion loss▪High return loss▪Easy of installation▪Low cost▪Reliability▪Low environmental sensitivity▪IEC standard compliance;▪Various housing and boot color for option;

Mold Type Cable color Boot Color

SM Simplex 0.9 Green Green

MM Duplex 1.2 Blue Blue

1.6 Beige Beige

2.0 Red Red

2.4 White

3.0

Items Single mode Multi mode

Insertion Loss ≤0.3dB ≤0.3dB

≥30dBReturn Loss ≥50dB(UPC); ≥60dB(APC)

Ceramic ferrule spec 125.5um concentricity deviations:<1um 127um concentricity deviations:<3um

Insert-pull test 1000 times<0.3dB

Operation temperature -40℃~+85℃

Suitable fiber PC/APC(9/125um) PC(50/125um,62.5/125um)

Page 12: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

Connector—FC/ST/DIN/SMA

FEATURE

FC 2.0mm ConnectorFC 3.0mm mesh Connector ST 2.0mm Connector ST 0.9mm Connector

DIN Connector

SMA Connector

10

PERFORMACE

FC/ST SPECIFICATIONS

▪Low insertion loss▪High return loss▪Easy of installation▪Low cost▪Reliability▪Low environmental sensitivity▪IEC standard compliance;▪Various housing and boot color for option;

Mold Cable Housing color Boot color Boot

SM 0.9 Metal Green short

MM 2.0

3.0

1.2 Blue long

1.6 Red

2.0

Items Single mode Multi mode

Insertion Loss ≤0.3dB ≤0.3dB

≥30dBReturn Loss ≥50dB(UPC); ≥60dB(APC)

Ceramic ferrule spec 125.5um concentricity deviations:<1um 127um concentricity deviations:<3um

Insert-pull test 1000 times<0.3dB

Operation temperature -40℃~+85℃

Suitable fiber PC/APC(9/125um) PC(50/125um,62.5/125um)

Page 13: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

Connector—MU/LSH/E2000

PERFORMACE

MU SPECIFICATION

LSH & E2000 SPECIFICATION

FEATURE

▪Low insertion loss▪High return loss▪Ease of installation▪Low cost▪Reliability▪Low environmental sensitivity▪Ease of use

MU 2.0mm Connector

MU 0.9mm Connector

LSH 2.0mm Connector

LSH 0.9mm Connector

E2000 2.0mm Connector

11

Items Single mode Multi mode

Insertion Loss ≤0.3dB ≤0.3dB

≥30dBReturn Loss ≥50dB(UPC); ≥60dB(APC)

Ceramic ferrule spec 125.5um concentricity deviations:<1um 127um concentricity deviations:<3um

Insert-pull test 1000 times<0.3dB

Operation temperature -40℃~+85℃

Suitable fiber PC/APC(9/125um) PC(50/125um,62.5/125um)

Mold Type Cable Housing color Boot Color

SM Simplex 0.9 Green Green

MM Duplex 2.0 Blue Blue

Beige Beige

Brown Brown

White

Mold Type Cable Housing color Boot Color

SM Simplex 0.9 Green Green

MM 2.0 Blue Blue

Page 14: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

Connector—MTP/MTRJ/MPO

MPO/MTP SPECIFICATION

FEATURE

▪Low insertion loss▪High return loss▪Easy of installation▪Low cost▪Reliability▪Low environmental sensitivity▪IEC standard compliance;▪ Various housing and boot color for option;

MPO/MTP PERFORMACE

MTRJ PERFORMACE

Single mode Multi mode

≤0.3dB ≤0.3dB

≥50dB(UPC); ≥60dB(APC) ≥30dB

125.5um concentricity deviations:<1um <

Insert - 1000 times <0.3dB

-40℃~+85℃

Items

Insertion Loss

Return Loss

Ceramic ferrule spec

pull test

Operation temperature

Suitable fiber PC/APC(9/125um)

127um concentricity deviations: 3um

PC(50/125um,62.5/125um)

ItemsElite Performance Std Performance

SM MM SM MM

Insertion Loss

12F 24F 12F 24F 12F,24F 12F,24F

≤0.35dB ≤0.5dB ≤0.35dB ≤0.7dB ≤0.7dB

Return Loss ≥55dB ≥20dB ≥55dB ≥20dB

Durability

Operation temperature

Fiber Type

500times

-40℃~+85℃

OS2/OM1/OM2/OM3/OM4

Mold Type Fiber Housing color Boot Color

SM 8F Ribbon Fiber Aqua Black

MM 12F Ø3.0 Yellow ……

SMLL 16F Ø3.6 Beige

MMLL 24F Ribbon cable Black

Violet

Green

MTRJ Connector

MPO Push - Pull Connector

MPO Ribbon Fiber Connector

MPO Round Cable Connector

MTP Round Cable Connector

NEW

NEW

NEW

MTP Ribbon Fiber Connector MTP Ribbon Cable Connector

12

Page 15: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

Connector—Ferrules

FEATURE

▪ Available for SM & MM, OD 1.25mm & 2.5mm, PC & APC▪ Applicable to SC/ST/FC/LC/MU/E2000/ DIN/SMA/D4/LX.5 connectors▪ Good reliability, high precision for concentricity, ID and OD▪ Compliant with RoSH, IEC and Telcodia-GR-326-Core▪ Non-standard ceramic zirconia ferrule optional

Our Ceramic Zirconia Ferrule sticks are manufactured according to strict quality and performance standards. We specially designed our Fiber Optic Ferrules for low insertion loss, low back reflection and superior durability.

Type

SM

MM

OD

2.499mm/1.249mm

2.499mm/1.249mm

Concentricity

≤1.0um

≤3.8um

ID

125-126/126-127um

126-130um

Length

10.4-10.5mm/6.4 -6.5mm

10.4-10.5mm/6.4 -6.5mm

SC FC Ferrule

LC Ferrule

ST Ferrule

Customized Ferrule

13

Page 16: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

Armored and Mode-conditioning Patch cord

ARMORED PATCH CORD

SPECIFICATION

Items Single mode Multi mode

Insertion Loss ≤0.3dB ≤0.3dB

Return Loss ≥50dB(UPC); ≥60dB(APC) ≥30dB

Durability 500times

Operation temperature -25℃~ +70℃

Fiber Type OS2/OM1/OM2/OM3/OM4

SPECIFICATION

Items Single mode Multi mode

Insertion Loss

9/125um 62.5/125um 50/125um

Single mode change to Multi mode<0.5 dB Multi mode change to Single mode<20dB

Optical Fiber diameter

Operation temperature -25℃~ +70℃

Mode-conditioning patch cords are designed for longwave(1310nm) Gigabit Ethernet applications over multimode fiber. They consist an offset connection of a SM fiber to a MM fiber. There are two MM fibers on one end and one MM and one SM fiber on the other. This patch cords is required with -LX or longwave Gigabit Ethernet transceivers that use both SM and MM fibers. When launching into a MM fiber, the transceivers can generate multiple signals that cause Differential Mode Delay (DMD) which can severely limit transmission distances. A mode conditioning patch cord removes these multiple signals, eliminating problems at the receiver end.

MOLD-CONDITIONING PATCH CORD

▪ Low insertion loss , high return loss ▪ Permanent displacement seal, low loss ▪ Adapt update cable design▪ Other connection mode available according customer requirements ▪ Screen different value delay effection▪ Substitute standard equipment-cable equipment patch cord

ST - ST Mode Conditioning Patch Cord

FC - FC Armored Patch Cord

14

▪ Full steel armoured protection from ceramic ferrule ▪ High tensile resistance & anti-pressure▪ Strong anti- ultraviolet radiation ▪ High flexibility

The armored optical fiber patch cord are used in central offices, customer premises or in outside plant applications. They will provide a flexible interconnection to the electronic equipment, to passive optical devices or provides a cross-connect function between different fibers. The fiber can be safeguard by stainless steel tube around the fiber.

SM MM Armored patch cord

Page 17: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

FTTA and FTTH Drop Patch cord

FTTA PATCH CORD

Hybrid feeder cabling solution was developed to reduce installation complexity and costs at cellular sites,allows mobile operatiors deploying an RRH architecture to standardize the RRH installation process and eliminate the need and cost of cable grounding.

SPECIFICATION

FTTH DROP PATCH CORD

FTTH drop cable patch cords are made of standard FTTH fiber optic cabling and are terminated with fiber optic connectors on both ends. It is easy and more convenient to operate in FTTH Constructions, push the connector to the Adapters. FTTH drop patch cords have been widely applied in Local Area Networks (LANs) and Wide Area Networks (WANs); Fiber Optic CATV, FTTH, FTTB, FTTP solutions; Fiber Optic telecommunication systems; Transmission Mode (ATM) and Fiber Optic Backbone

Single mode

≤0.3dB

≥50dB(UPC); ≥60dB(APC)

Multi mode

≤0.3dB

≥30dB

Items

Insertion Loss

Return Loss

Durability

Operation temperature

Fiber Type

500times

-25℃~ +70℃

OS2/OM1/OM2/OM3/OM4

SC - SC Drop Patch Cord

FC - FC Drop Patch Cord

15

▪ High tensile resistance & anti-pressure▪ Easy bending and wiring▪ High protectiveness with strengthening cores▪ Simplex, duplex, four-core and multi-core available▪ Comply with Telcordia GR-1435-CORE and RoHS standard

▪ Low insertion loss , high return loss ▪ General use waterproof, adapt for outdoor hard environment ▪ All parts compliant with RoHS

Page 18: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

MPO/MTP/LC/SC Loopback Patch cord

▪Different IL index and various color available ▪SM or MM available; PC(plane) or APC(8 degree) available▪Stable performance index by PIN fiexed position of connectingl▪Standard Fiber arrangement or customizedl▪Plug type connector with locking structure▪High density which convenient for wiring and management system Comply with Telcordia GR-1435-CORE and RoHS standard

FEATURE

MPO/MTP loopback patch cord mainly used for optical fiber communication networks, It used mini-breakout LSZH cable and high-precision MPO connector, can fully guaranteed the inspection and testing process stability and accuracy, It effectively saves the space and test costs.

SC/LC loopback patch cord are designed for testing, engineering and the burn-in stage of boards or other equipment. They provide system test engineers a simple but effective way of testing the transmission capability and receiver sensitivity of network equipment. One connector is plugged into the output port, while the other is plugged into the input port of the equipment.

MPO/MTP SPECIFICATION

ItemsElite Performance Std Performance

SM MM SM MM

Insertion Loss8F,12F 24F 8F,12F 24F 8F,12F 24F 24F2F,8F,12F

≤0.7dB ≤1.0dB ≤0.7dB ≤1.4dB ≤1.4dB

Return Loss NA NA NA NA

Durability 500times

Operation temperature -20℃~ +70℃

Fiber Type OS2/OM3/OM4

MTP Mini Jumper Loopback LC Loopback

LC Mini Jumper Loopback

SC Mini Jumper Loopback

SC Loopback

16

Page 19: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

Pigtail and Breakout patch cords

DESCRIPTION

The patch cord can be used in interconnect or cross-connect path connecting the incoming fibers to the electronic equipment and providing patching within the fiber paths. �The 9/125µm single mode fiber patch cord meets RoHS compliant, and all cables are 100% optically tested for insertion loss to ensure high quality, it is very cost-effective for network cabling.

The high density design can scale up to 24 fibres . It is the perfect solution for trunks requiring various LC/SC/FC/ST interface and universal or external applications;

SPECIFICATION

SPECIFICATION

BREAKOUT PATCH CORD

The high density design can scale up to 144 fibres . It is the perfect solution for trunks requiring various LC/SC/FC/ST interface and universal or external applications

MINI PATCH CORD

Items

Random Mating according to IEC 61300 -3-34

Grade A Grade B Grade CAverage Max

Average Max (97%) Average Max (97%) Average Max (97%)

Insertion Loss ≤0.08dB ≤0.15dB ≤0.12dB ≤0.25dB ≤0.25dB ≤0.5dB ≤0.25dB ≤0.30dB

Return Loss ≥ 50dB(PC), ≥50dB(UPC); ≥60dB(APC) ≥ 30dB(PC)

Durability 500times

Operation temperature -25℃~+70℃

Fiber Type OS1/OS2 OM1/OM2/OM3/OM4/OM5

Against Master Connector according to IEC 61300-3-4

Items Single mode Multi mode

Insertion Loss ≤0.3dB ≤ 0.3dB

Return Loss ≥50dB(UPC); ≥60dB(APC) 3≥ 0 dB

Durability 500times

Operation temperature ℃

Fiber Type OS2/OM1/OM2/OM3/OM4

- 25 ~ ℃+70

Pigtails

SC Fan-out Pigtails

24ch LC - SC Mini Patch Cord

12ch LC - SC Mini Patch Cord

17

▪ Stable and reliable process▪ Low insertion loss ▪ Perfect random mating performance

▪ Mode of patch cord ( connected with two ends) or mode of pigtail (only one end connected) are available to choice ▪ Number of fibers: 4, 6, 8 or 12 (more than 24 cores are available upon request)▪ Standard length from fan out to connector: 1 meter or customize specifications are available

▪ Mode of patch cord ( connected with two ends) or mode of pigtail (only one end connected) are available to choice ▪ Number of fibers: 4, 6, 8 or 12 (more than 12 cores are available upon request)▪ Standard length from fan out to connector: 1 meter or customize specifications are available

PIGTAIL

Page 20: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

18

Attenuator—LC/SC/FC/ST/MU

SC Attenuator

FC Attenuator

MU Attenuator

ST Attenuator

LC Attenuator

PERFORMACE

FEATURE

▪High return loss▪Simple structure▪Max operation power ( 500mw )▪Low wavelength relativity▪Low polarization related loss▪Compact design

Our Ceramic Zirconia Ferrule sticks are manufactured Fiber optic attenuator is a device used to reduce the power level of an optical signal, either in free space or in an optical fiber. The basic types of optical attenuators are fixed, step-wise variable, and continuously variable.

Attenuation value 1 3 5 10 15 20 25 dB

Attenuation precision1~10dB (±0.5dB)≥10dB (±10%dB)

Return Loss PC>40dB APC>55dB

Operation wavelength 1310nm and 1550nm(SM)

Polarization loss ≤0.1dB

Operation temperature -40℃~+70℃

Temperature(Unencapsulation)

95%RH Apply to Telecordia standard(GR-910-CORE)

Page 21: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

19

PLC—250µm bare fiber

1X4 PLC Splitter

1X8 PLC Splitter

1X16 PLC Splitter

1X32 PLC Splitter

1X64 PLC Splitter

FEATURE

SPECIFICATION

▪ Low Insertion Loss,Low PDL▪ Good Channel to Channel uniformity▪ Wide Operating wavelength From 1260-1650nm▪ Compact Design▪ Output side ribbon fiber is very convenient for ribbon splicing

Parameters 2x2 2x4 2x8 2x16 2x32 2x641x2 1x4 1x8 1x16 1x32 1x64

Operating wavelength(nm) 1260~1650

Fiber type G652D/G657A1/G657A2

Insertion Loss(dB) 4 4.2 7.2 7.4 10.5 10.8 13.7 14 17 17.5 20.6 21

Uniformity(dB) 0.4 1 0.6 1.5 0.8 1.5 1.2 2 1.5 2 2 2.5

Return Loss(dB) 55 55 55 55 55 55

PDL(dB) 0.2 0.3 0.2 0.3 0.2 0.3 0.3 0.3 0.3 0.3 0.35 0.5

Directivity (dB) 55 55 55 55 55 55

0.5 0.5 0.5 0.5 0.5 0.5

Operating temperature (℃) -40~85

Storage temperature (℃) -40~85

Steel Tube Dimension

(LxWxH)40x4x4 40x4x4 40x4x4 50x4x4 50x7x4 60x12x4

Temperature Stability-40~85 ℃)(dB)(

Page 22: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

1X32 ABS type PLC Splitter

20

PLC—Adaptor-input ABS type Splitter

FEATURE

SPECIFICATION

▪ Low Insertion Loss,Low PDL▪ Good Channel to Channel uniformity▪ Wide Operating wavelength From 1260-1650nm▪ Using adaptor as input port▪ Input and output cable:OD2.0mm, Good Mechanical performance, convenient for connector assembly

Parameters 2x2 2x4 2x8 2x16 2x32 2x641x2 1x4 1x8 1x16 1x32 1x64

Operating wavelength(nm) 1260~1650

Fiber type G652D/G657A1/G657A2

Insertion Loss(dB) 4 4.2 7.2 7.4 10.5 10.8 13.7 14 17 17.5 20.6 21

Uniformity(dB) 0.4 1 0.6 1.5 0.8 1.5 1.2 2 1.5 2 2 2.5

Return Loss(dB) 55 55 55 55 55 55

0.5 0.5 0.5 0.5 0.5 0.5

Operating temperature (℃) -25~70

Storage temperature (℃ ) -25~70

ABS box dimension

(LxWxH) mm100x80x10 100x80x10 100x80x10 120x80x18 140x115x18 140x115x18

Notes: Add an additional 0.3dB loss per connector.

0.2 0.3 0.2 0.3 0.2 0.3 0.3 0.3 0.3 0.3 0.35 0.5PDL(dB)

55 55 55 55 55 55Directivity (dB)

Temperature Stability(-40~ ℃)(dB)85

Page 23: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

21

PLC—LGX box PLC Splitter

2X32 PLC Splitter

FEATURE

▪ Low Insertion Loss, Low PDL▪ Good Channel to Channel uniformity▪ Wide Operating wavelength From 1260-1650nm▪ Compact Design▪ plugging and unplugging conveniently by means of patch cords with patch latch

SPECIFICATION

Parameters 2x2 2x4 2x8 2x16 2x32 2x641x2 1x4 1x8 1x16 1x32 1x64

Operating wavelength(nm) 1260~1650

Fiber type G652D/G657A1/G657A2

Insertion Loss(dB) 4 4.2 7.2 7.4 10.5 10.8 13.7 14 17 17.5 20.6 21

Uniformity(dB) 0.4 1 0.6 1.5 0.8 1.5 1.2 2 1.5 2 2 2.5

Return Loss(dB) 55 55 55 55 55 55

0.5 0.5 0.5 0.5 0.5 0.5

Operating temperature (℃) -25~70

Storage temperature (℃ ) -25~70

LGX Dimension(LxWxH) mm

115.5x86x18/155.5x129x29

0.2 0.3 0.2 0.3 0.2 0.3 0.3 0.3 0.3 0.3 0.35 0.5PDL(dB)

55 55 55 55 55 55Directivity (dB)

Temperature Stability(-40~ ℃)(dB)85

Page 24: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

FEATURE

HYC’s 4/ 6/ 8-1x2 PLC Splitter integrates up to 8 waveguides into one chip for reducing size and cost savings. 8-1x2 can be used independently without disturbing each other. It has good parameters of insert loss, good directivity and stable return loss and so on.

SPECIFICATION

Parameters 4-1x2 6-1x2 8-1x2

Operating wavelength(nm) 1260~1650

Fiber type G652D/G657A1/G657A2

Insertion Loss(dB) 4.0

Uniformity(dB) 0.4

Return Loss(dB) 55

PDL(dB) 0.2

Directivity (dB) 55

Temperature Stability

(-40~85 ℃)(dB)0.5

45x5x4(250um)/70x12x4(900um)/120x80x18(2.0 or 3.0mm)

Operating temperature (℃) -40~85

Storage temperature (℃)

Storage temperature (℃)

-40~85

(LxWxH) mm

▪ Low Insertion Loss, Low PDL▪ Good channel to channel uniformity▪ High integration chip▪ Wide operating wavelength from 1260-1650nm▪ Compact design, save space▪ A variety of package structure

22

PLC—4/ 6/ 8-1x2 PLC Splitter Device

8-1x2 PLC Splitter Device

Page 25: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

23

PLC—compact size Mini module

1x16 PLC Compact Mini Module

FEATURE

▪ Low Insertion Loss,Low PDL▪ Good Channel to Channel uniformity▪ Wide Operating wavelength From 1260-1650nm▪ Compact Design, ABS BOX Size:100x45x10mm▪ Input and output cable:900um, Good protecting for bare fiber, convenient for connector assembly

HYC's Mini ABS PLC splitter is commonly used in PON network, and has a good protective effect for the internal optical components and cables. It has simple design and reliable installation. These products have been widely used in outdoor distribution box and network cabinets.

SPECIFICATION

Parameters 1 ×16 2 x 16

Operating wavelength(nm) 1260 ~ 1650

Fiber type G652D/G657A1/G657A2

Insertion Loss(dB) 14.0 14.3

Uniformity(dB) 1.2 2

Return Loss(dB)

PDL(dB) 0.3 0.3

Directivity (dB)

Temperature Stability

(-40~85 ℃ )(dB)

55

55

0.5

Operating temperature (℃ ) -40~ 85

Storage temperature (℃ ) -40~ 85

ABS Dimension (LxWxH) mm 100x45x10

Page 26: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

PLC—Rack Type PLC Splitter

Notes: Add an additional 0.3dB loss per connector.

FEATURE

▪ Low Insertion Loss,Low PDL▪ 19” standard installation,It is compatible for ETSI installation typ▪ Module design, slideway tray structure, easy to Install▪ Easy to maintain, high reliability▪ Compatible for 1x2~2x64 PLC splitter

HYC’s rack type PLC Splitter consists of the PLC splitters and the enclosure body, it is with standard size and for easy installation, there are many adaptor interfaces optional such as SC, LC and FC. The rack type PLC splitters suit for the indoor or outdoor applications in FTTx projects, CATV or data communication centers.

SPECIFICATION: (WITHOUT CONNECTORS)

2x21x2 2x41x4 1x8 2x8 2x161x16 2x321x32 2x641x64

4 4.2 7.2 7.4 10.5 10.8 13.7 14 17 17.5 20.6 21

0.4 1 0.6 1.5 0.8 1.5 1.2 2 1.5 2 2 2.5

55 55 55 55 55 55

0.2 0.3 0.2 0.3 0.2 0.3 0.3 0.3 0.3 0.3 0.35 0.5

55 55 55 55 55 55

0.5 0.5 0.5 0.5 0.5 0.5

Parameters

Operating wavelength(nm)

Fiber type

Insertion Loss(dB)

Uniformity(dB)

Return Loss(dB)

PDL(dB)

Directivity (dB)

Temperature Stability

(-40~85 ℃ )(dB)

Operating temperature ( ℃ )

Storage temperature ( ℃ )

1260 ~1650

G652D/G657A1/G657A2

40~85-

-40~85

1x32 Rack type PLC Splitter

24

Page 27: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

25

PLC—Plug-in Type PLC Splitter

FEATURE

▪ Low Insertion loss, high return loss, Loss,Low PDL▪ plug-in type saves time and space but still provides reliable protection for the fiber optic splitter▪ The ABS material of the outer box has excellent high and low temperature performance and good chemical resistance

HYC's plug-in type PLC splitter is a type of optical power management device that is fabricated using silica optical waveguide technology. It features high reliability, wide operating wavelength range and good channel-to-channel uniformity, and is widely used in PON networks to realize optical signal power splitting. We provides whole series of 1xN and 2xN splitter products that are tailored for specific applications.

SPECIFICATION: (WITHOUT CONNECTORS)

Parameters 2x2 2x4 2x8 2x16 2x32 2x641x2 1x4 1x8 1x16 1x32 1x64

Operating wavelength(nm) 1260~1650

Fiber type G652D/G657A1/G657A2

Insertion Loss(dB) 4.0 4.2 7.2 7.4 10.5 10.8 13.7 14.0 17.0 17.5 20.6 21.0

Uniformity(dB) 0.4 1 0.6 1.5 0.8 1.5 1.2 2 1.5 2 2 2.5

Return Loss(dB) 55 55 55 55 55 55

PDL(dB) 0.2 0.3 0.2 0.3 0.2 0.3 0.3 0.3 0.3 0.3 0.35 0.5

Directivity (dB) 55 55 55 55 55 55

Temperature Stability(-40~85℃)(dB) 0.5 0.5 0.5 0.5 0.5 0.5

Operating temperature (℃) - 40 ~85

Storage temperature (℃) - 40 ~85

1x32 Plug - in type PLC Splitter

1x8 Plug - in type PLC Splitter

Page 28: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

FEATURE

SPECIFICATION: (WITHOUT CONNECTORS)

▪ Low Insertion Loss, Low PDL▪ High Return loss▪ Compact Size▪ High stability and reliability▪ Standard: RoHS Compliant▪ Optional Split Ratio 20/80, 40/60...(50/50 as default)

Parameters Wind band coupler

(WBC) Dual-window coupler (DWC) Three-window coupler (TWC)

Operating wavelength

(nm) 1310 or 1550 1310 and 1550 1310, 1490 and 1550

Operating bandwidth 1310±40 or 1550±40 1310/1550±40 1310/1550±40and 1490±10

Grade P A P A P A

IL (dB)

50/50 ≤3.4 ≤3.6 ≤3.6 ≤3.8 ≤3.6 ≤3.8

40/60 ≤4.4/2.6 ≤4.7/2.8 ≤4.7/2.7 ≤4.9/2.9 ≤4.7/2.7 ≤4.9/2.9

30/70 ≤5.7/1.9 ≤6.0/2.0 ≤6.0/1.9 ≤6.3/2.1 ≤6.0/1.9 ≤6.3/2.1

20/80 ≤7.6/1.25 ≤8.0/1.3 ≤7.9/1.3 ≤8.4/1.4 ≤7.9/1.3 ≤8.4/1.4

10/90 ≤11.0/0.65 ≤

11.5/0.8 ≤9.2-11/0.75 ≤8.8-11.4/0.8 ≤9.2-11/0.75 ≤8.8-11.4/0.8

5/95 ≤14.2/0.4 ≤

14.8/0.5

3/97 ≤16.7/0.3 ≤

17.2/0.4

2/98 ≤18.5/0.25 ≤

19/0.35 ≤15.0-19.2/0.4

1/99 ≤21.5/0.2 ≤

22.0/0.3 ≤17.8-22.4/0.35

≤15.0-19.2/0.4

≤17.8-22.4/0.35

PDL(dB) ≤0.1 ≤0.15 ≤0.15 ≤0.2 ≤0.15 ≤0.2

Return Loss(dB) ≥55

Directivity (dB) ≥55

Temperature Stability

(-40~85 ℃)(dB) ≤0.2

Operating temperature -40~+85

Storage temperature -40~+85

Fiber type Corning SM SMF -28, G652D

Fiber diameter (mm) 0.25 0.9 2.0 3.0

Package (mm) 3x45/3x54 3x54/3x60 90x20x10

) ℃(

) ℃(

12.05-14.2/0.4

11.55-14.65/0.5

12.05-14.2/0.4

11.55-14.65/0.5

14.1-16.5/0.35

15.6-18.55/0.3

15.6-18.55/0.3

18.45-21.7/0.25

18.45-21.7/0.25

13.6-17.05/0.45

14.1-16.5/0.35

13.6-17.05/0.45

Notes:1.The above specification is without connectors.2.Add an additional 0.2dB loss per connector.

26

PLC—1x2 SM FBT/ ABS Type SM FBT

1x2 FBT type PLC Splitter

Page 29: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

PLC—PLC Splitter Mini Fan-out

FEATURE

▪ Low Insertion Loss,Low PDL▪ Good Channel to Channel uniformity▪ Wide Operating wavelength From 1260-1650nm▪ Compact Design▪ Input and output cable:900um, Good protecting for bare fiber, convenient for connector assembly

HYC's PLC splitter with Fan-out series is mainly used for 0.9 mm fiber, where the fiber ribbon can be converted into a 0.9 mm fiber through a Fan-out. These products are suitable for both insert boxes and wall-mounted boxes applications.

Parameters 2x2 2x4 2x8 2x16 2x32 2x641x2 1x4 1x8 1x16 1x32 1x64

Operating wavelength(nm) 1260~1650

Fiber type G652D/G657A1/G657A2

Insertion Loss(dB) 4 4.2 7.2 7.4 10.5 10.8 13.7 14 17 17.5 20.6 21

Uniformity(dB) 0.4 1 0.6 1.5 0.8 1.5 1.2 2 1.5 2 2 2.5

Return Loss(dB) 55 55 55 55 55 55

PDL(dB) 0.2 0.3 0.2 0.3 0.2 0.3 0.3 0.3 0.3 0.3 0.35 0.5

Directivity (dB) 55 55 55 55 55 55

Temperature Stability(-40~85℃)(dB) 0.5 0.5 0.5 0.5 0.5 0.5

Operating temperature (℃) - 40 ~85

Storage temperature (℃) - 40 ~85

SPECIFICATION

Notes: Add an additional 0.3dB loss per connector.

1x32 Mini Fan - out PLC Splitter

27

Page 30: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

28

WDM— 3-port WDM

FEATURE

FEATURE

3-port FWDM devices are used in passive optical WDM module; They can Multiplex or Demultiplex different optical signals in Wavelength Division Multiplexing system, and Increase the signal transmission speed and communication capacity.

3-port CWDM devices are used in passive optical WDM module; They can Multiplex or Demultiplex different optical signals in Wavelength Division Multiplexing system, and Increase the signal transmission speed and communication capacity.

SPECIFICATION

SPECIFICATION

3-PORT FWDM&MINI FWDM DEVICE

3-PORT CWDM&MINI CWDM DEVICE

Items

Pass band 1540~1560nm(customer specified)

Pass band 1260~1360&1480~1500nm(customer specified)

Transmission band Insertion Loss ≤0.6 dB ≤0.6 dB

Reflection band Insertion Loss ≤0.4 dB ≤0.4 dB

Isolation ≥30dB

Return Loss ≥50 dB

Directivity ≥50 dB

Ripple ≤0.3 dB

Package Dimension Ф4.0xL30mm Ф3.2xL30mm & Ф3.0xL30mm

Operation temperature

Items 3 -port CWDM 3 -port Mini CWDM

3 -port FWDM 3 -port Mini FWDM

Operating wavelength 1260-1620nm & 1460-1620nm

Pass band ± 6.5nm ±7.0nm ± 7.5nm

Transmission band Insertion Loss ≤0.6 dB ≤0.6 dB

Reflection band Insertion Loss ≤0.4 dB ≤0.4 dB

Isolation ≥30dB

Return Loss ≥50 dB

Directivity ≥50 dB

Ripple ≤0.3 dB

Package Dimension Ф4.0xL30mm

Operation temperature

3 - Port FWDM/Mini FWDM Device

3 - Port CWDM /Mini CWDM Device

-40℃~ +85 ℃

-40℃~ +85 ℃

Ф3.2xL30mm & Ф3.0xL30mm

Page 31: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

29

WDM— 3-port WDM

FEATURE

3-port DWDM devices are used in passive optical WDM module; They can Multiplex or Demultiplex different optical signals in Wavelength Division Multiplexing system, and Increase the signal transmission speed and communication capacity.

SPECIFICATION

3-PORT DWDM&MINI DWDM DEVICE

Items 3 -port DWDM 3 -port Mini DWDM

Operating wavelength 1500-1600nm

Channel Spacing 100G 、200G

Pass band ±0.12nm 、±0.25nm

Transmission band

Insertion Loss≤0.7dB ≤0.7dB

Reflection band

Insertion Loss≤0.4dB ≤0.4dB

Isolation ≥28dB

Return Loss ≥50dB

Directivity ≥45dB

Ripple ≤0.3dB

Package Dimension Ф4.0xL30mm Ф3.2xL30mm

& Ф3.0xL30mm

Operation temperature

3 - Port DWDM /Mini DWDM Device

-40℃~ +85 ℃

Page 32: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

30

WDM— 8ch CWDM/DWDM ABS Module

FEATURE

FEATURE

The 8ch CWDM Module packaged in a compact ABS box performs 8ch CWDM signals MUX/DEMUX function. This BOX has small size and takes up less installation space in system.

The 8ch DWDM Module packaged in a compact ABS box performs 8ch DWDM signals MUX/DEMUX function. This BOX has small size and takes up less installation space in system.

SPECIFICATION

SPECIFICATION

8CH CWDM ABS MODULE

8CH DWDM ABS MODULE

8CH CWDM Module

1260-1620nm

±6.5nm 、±7.0nm 、±7.5nm

≤2.5 dB

≥30dB

≥45dB

≥50 dB

≥50 dB

≤0.5 dB

L100 x W80 x H10mm & L80 x W60 x H12mm

Items

Operating wavelength

Pass band

Insertion Loss

Adjacent Channel Isolation

Non Adjacent Channel Isolation

Return Loss

Directivity

Ripple

Package Dimension

Operation temperature

Items 8CH DWDM Module

Operating wavelength

Channel Spacing

Pass band

Insertion Loss ≤2.5 dB

Adjacent Channel Isolation ≥28dB

Non Adjacent Channel Isolation ≥45dB

Return Loss ≥50dB

Directivity ≥45dB

Ripple ≤0.5 dB

Package Dimension L100 x W80 x H10mm & L80 x W60 x H12mm

8ch CWDM ABS Module

8ch DWDM ABS Module

-40℃~ +85 ℃

1500-1600nm

100G 、200G

±0.12nm 、±0.25nm

Page 33: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

31

WDM— CCWDM/LANWDM Module

FEATURE

CCWDM is based on thin film filter technology and free space package technology;It features small form factor, ultra low insertion loss, high channel isolation and no epoxy in the optical path.

SPECIFICATION

CCWDM Module

FEATURE

LAN WDM is based on thin film filter technology and freespace package technology;It features small form factor,ultra low insertion loss, high channel isolation and no epoxy in the optical path.

SPECIFICATION

LAN WDM Module

Items

Operating wavelength

Pass band

Insertion Loss

Adjacent Channel Isolation

Non Adjacent Channel Isolation

Return Loss

Ripple

Package Dimension

Operation temperature

4CH 8CH

1260-1620nm

± 6.5nm

≤1.4dB ≤1.7dB

≥ 30dB

≥ 45dB

≥50dB

≤0.5dB

L50 x w27 x H7.7mm

Items Specifications

Operating wavelength 1271 、 1291 、 1311 、 1331 1295.56, 1300.06, 1304.59, 1309.14

Pass band ±6.5nm

Insertion Loss ≤1.5dB

Adjacent Channel Isolation ≥30dB

Non Adjacent Channel Isolation ≥45dB

Return Loss ≥50dB

±1.0nm

≤1.5dB

≥25dB

≥45dB

≥50dB

Ripple ≤ 0.5dB

Package Dimension L20 x W12 x H5.7mm

Operation temperature

CCWDM Demux Module

LANWDM Module

-40℃~ +85 ℃

- 5℃~ +85 ℃

Page 34: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

32

WDM—CWDM/DWDM Module

FEATURE

FEATURE

The 8ch CWDM Module packaged in a compact Aluminum box performs 8ch CWDM signals ADD/DROP function. This BOX has smaller size than ordinary one and takes up less installation space in system.

The 8ch DWDM Module packaged in a compact Aluminum box performs 8ch DWDM signals ADD/DROP function. This BOX has smaller size than ordinary one and takes up less installation space in system.

SPECIFICATION

SPECIFICATION

CWDM OADM module

DWDM OADM module

Items 4CH 8CH

Operating wavelength

Pass band

Insertion Loss

Adjacent Channel Isolation

Non Adjacent Channel Isolation

Return Loss

Directivity

Ripple

Package Dimension

Operation temperature

1260-1620nm 、1460-1620nm

±6.5nm 、±7.0nm

≤1.7dB ≤3.0dB

≥30dB

≥45dB

≥50dB

≥50dB

≤0.5dB

L100 x W80 x H10mm L115 x W85 x H8mm

Items 4CH 8CH

Operating wavelength 1500-1600nm

Channel Spacing 100G 、200G

Pass band ±0.11nm 、±0.25nm

Insertion Loss ≤1.7 dB ≤3.0 dB

Adjacent Channel Isolation ≥28dB

Non Adjacent Channel Isolation ≥45dB

Return Loss ≥50 dB

Directivity ≥45 dB

Ripple ≤0.5 dB

Package Dimension L100 x W80 x H10mm L115 x W85xH8mm

CWDM 8+1ch Mux/Demux Module

DWDM 8+1ch Mux/Demux Module

-40℃~ +85 ℃

Page 35: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

33

WDM— CWDM/DWDM insert-box module

FEATURE

Compact insert-box WDM Module performs 8ch CWDM signals MUX/DEMUX function. This box has smaller size than ordinary one and takes up less space in system and very easy to be used in distributing cabinet or rack.

SPECIFICATION

8ch CWDM/DWDM insert-box module

8CH CWDM Module

1260-1620nm

±6.5nm 、±7.0nm 、±7.5nm

8CH DWDM Module

1500-1600nm

±0.12nm

Non Adjacent Channel

Isolation

Items

Operating wavelength

Pass band

Insertion Loss

Adjacent Channel Isolation

Return Loss

Directivity

Ripple

Package Dimension

Operation temperature

≤2.5dB

≥30dB

≥45dB

≥50dB

≥50dB

≥28dB

≥45dB

≤0.5dB

L100 x W118 x H20mm

8ch CWDM insert box Module

-40℃~ +85 ℃

Page 36: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

34

WDM—CWDM/DWDM/FWDM LGX module

CWDM LGX Module

DWDM LGX Module

FWDM LGX Module

FEATURE

FEATURE

Compact LGX WDM Module performs 8ch CWDM signals MUX&DEMUX or 16ch CWDM signals MUX/DEMUX. This LGX has smaller size than ordinary one and takes up less space in system.

Compact LGX WDM Module performs 8ch DWDM signals MUX&DEMUX or 16ch DWDM signals MUX/DEMUX. This LGX has smaller size than ordinary one and takes up less space in system.

SPECIFICATION

SPECIFICATION

CWDM LGX module

DWDM LGX module

FEATURE

The LGX box multiplexes 1310、1490、1550 signals into an optical fiber, it can reduce access costs and meet the high bandwidth requirements of integrated services such as data, voice, and CATV, and are widely used in triple play and FTTX Technology.

SPECIFICATION

FWDM LGX module

Items 8ch CWDM 16ch CWDM

Operating wavelength

Pass band

Insertion Loss ≤2.5dB ≤4.0dB

Adjacent Channel Isolation ≥30dB

Non Adjacent Channel Isolation ≥45dB

Return Loss ≥50dB

Directivity ≥50dB

Ripple ≤0.5dB

Package Dimension L90 x w61x H26mm L90 x w61x H52mm

Operation temperature

8ch DWDM 16ch DWDM

≤2.5dB ≤4.0dB

≥ 28dB

≥45dB

≥50dB

≥45dB

≤0.5dB

L90 x w61 x H26mm L90 x w61 x H52mm

Items

Operating wavelength

Pass band

Insertion Loss

Adjacent Channel Isolation

Non Adjacent Channel Isolation

Return Loss

Directivity

Ripple

Package Dimension

Operation temperature

FWDM MUX&DEMUX

1260-1360nm(upstream) 1480-1500nm(downstream)

≤1.2dB (for IP) ≤0.8dB ( for CATV )

Items

Wavelength for IP

Wavelength for CATV

Insertion Loss

Isolation @IP port

Isolation @ CATV port

Return Loss

Directivity

PDL

Package Dimension

Operation temperature

1540-1560nm

≥30dB

≥15dB

≥50dB

≥50dB

≤0.2dB

L180 x W100 x H29mm

1260-1620nm

1260-1620nm

-40℃~ +85 ℃

-40℃~ +85 ℃

-40℃~ +85 ℃

±6.5nm 、±7.0nm 、±7.5nm

±6.5nm 、±7.0nm 、±7.5nm

Page 37: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

35

WDM—19" Rack and GPON Module

FEATURE

19〞rack WDM Module could be inserted 3 LGX modules,and used in wavelength division multiplexing system directly;It makes more convenient for customers to use by the Plug and play form.

SPECIFICATION

19" rack WDM Module

FEATURE

This 64 channels GPON Module integrates WDM Devices PLC and MPO connectors; It supports 64 channels CATV signal and IP signal transmission.

SPECIFICATION

GPON module

8CH CWDM MUX/DEMUX

1260-1620nm

≤2.5dB

≥30dB

≥45dB

≥50dB

≥50dB

≤0.5dB

8CH DWDM MUX/DEMUX

1500-1600nm

±0.12nm

≤3.0dB

≥28dB

≥45dB

≥50dB

≥45dB

≤0.5dB

Items

Operating wavelength

Pass band

Insertion Loss

Adjacent Channel Isolation

Non Adjacent Channel Isolation

Return Loss

Directivity

Ripple

Package Dimension

Operation temperature

L430 x W250 x H29mm

Items

Wavelength for IP

Wavelength for CATV

Insertion Loss

Isolation / IP_Downstream to CATV

Isolation / IP_Upstream to CATV

Return Loss

Directivity

PDL

Package Dimension

Operation temperature

≤1.5dB (for IP) ≤21.5dB (for CATV)

≥18dB

≥30dB

≥50dB

≥50dB

≤0.3dB

L430 x W250 x H29mm

19” Rack WDM Module

GPON Module

1260-1360nm(upstream) 1480-1500nm(downstream)

1540-1560nm

-40℃~ +85 ℃

-40℃~ +85 ℃

±6.5nm 、±7.0nm 、±7.5nm

Page 38: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

36

PLC+WDM Module and 6-port CWDM/DWDM

FEATURE

FEATURE

This 32-channels FWDM+PLC Module integrates FWDM Devices、PLC and LC connectors; It supports 32 channels CATV signal and IP signal transmission.

6-port CWDM/DWDM devices are used in passive optical WDM module; Because the compact design, its dimension is the same with a 3-port device and it can be used as two 3-port devices in WDM module, but the cost is almostly as the same with a 3-port device.

SPECIFICATION

SPECIFICATION

PLC+WDM Module

6-port CWDM/DWDM

PLC+WDM Module

≤1.5dB (for IP) ≤18.5dB (for CATV)

≥30dB

≥15dB

≥50dB

≥50dB

≤0.3dB

L120 x w80 x H18mm

6 -port CWDM

≤0.7dB

≤0.4dB

≥30dB

≥45dB

≥50dB

≥50dB

6 -port DWDM

±0.12nm

≤0.85dB

≤0.55dB

≥28dB

≥45dB

≥50dB

≥45dB

Items

Operating wavelength

Pass band

Transmission band Insertion Loss

Reflection band Insertion Loss

Adjacent Channel Isolation

Non Adjacent Channel Isolation

Return Loss

Directivity

Ripple

Package Dimension

Operation temperature

≤0.3dB

Ф4.0xL30mm & Ф5.5xL38mm

PLC+WDM Module

6 Port DWDM

Items

Wavelength for IP

Wavelength for CATV

Insertion Loss

Isolation @ IP PORT

Return Loss

Directivity

PDL

Package Dimension

Operation temperature

Isolation @ CATV port

1260-1360nm(upstream) 1480-1500nm(downstream)

1540-1560nm

1260-1620nm 1500-1600nm

-40℃~ +85 ℃

-40℃~ +85 ℃

±6.5nm 、±7.0nm 、±7.5nm

Page 39: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

37

Data Center Solutions—Module and ODF

24F Cassette with Duplex Adapter

24F Cassette with Quad Adapter

1U Solution

2U Solution

4U Solution

FEATURE

▪ 24F Cassette with Duplex adapter or Quad adapter;▪ 19〃Rack mount,2 Cassettes each layer;▪ 6Pcs Independent Trays for 1U 144C LC;▪ 12Pcs Independent Cassettes for 2U 288C LC;▪ 24Pcs Independent Cassettes for 4U 576C LC;▪ Label space available, for visible connection;▪ Compliance with EI A / TIA568C ;▪ Easy capacity expansion and operation ;▪ Light Weight Design(Aluminum).

SPECIFICATION

Items

Size

Weight(with cassette)

Fiber Capacity

1U ODF

435*470*44mm

3.7kg

LC144 cores/SC 72 cores

2U ODF

435*470*88mm

6.4kg

LC 288 cores/SC 144 cores

4U ODF

435*470*176mm

11.2kg

LC 576 cores/SC 288 cores

Operation temperature -40℃~ +85℃

Patch cord Type MPO/MTP-LC/SC Patch cord

Page 40: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

38

Data Center Solutions—Mini and AOC patch cord

FEATURE

MT-MT PATCH CORD

SPECIFICATION

SPECIFICATION

▪ Cross or parallel connecting ▪ 40G/100G transmission speed▪ Standard or low loss can be optional▪ 8Cores or 12 cores can be optional▪ GR-1435-Core compliance▪ The length is specified by customer▪ Ribbon fiber or separated fiber convenient for inside connection

▪ Lighter weight ▪ Smaller Size ▪ Smaller bend radius ▪ Comply with RoHS

MT-MT patch cord is used in optical QSFP Module, Connect the optical lens with external port, OM2/OM3/OM4 fiber can be used, the length is very precise to meet the small space

Active optical cable is connecting with the trancevier using it the Data center

Items Elite Performance Std Performance

Insertion Loss ≤0.35 dB ≤0.5 dB

Return Loss PC≥20 dB ≥ 20dB

Durability 500times

Operation temperature -40 ℃ ~ +85 ℃

Fiber Type OM2/OM3/OM4

AOC PATCH CORD

Items Multi mode(LC) Multi mode(MT)

Insertion Loss ≤0.3dB ≤0.5dB

Return Loss ≥ 30dB ≥20dB

Durability 500times 500times

Operation temperature -40℃~ +85℃

Fiber Type OM2/OM3/OM4

MT - FA Mini Patch Cord

MT - MT Mini Patch Cord

LC - LC AOC Patch Cord

MT- MT AOC Patch Cord

Page 41: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

39

Data Center Solutions-MPO/MTP Patch Cord

FEATURE

▪SM or MM available; PC(plane) or APC(8 degree) available▪Different IL index and various color available▪Stable performance index by PIN fiexed position of connectingl▪Plug type connector with locking structurel▪High density which convenient for wiring and management system▪Comply with Telcordia GR-1435-CORE and RoHS standard

▪8-12 core fiber available ▪Cross Connection : AB/BA▪Paralled Connection : AB/AB ▪Small volume, easy management▪Insertion Loss : Low IL & Standard IL available ▪Can customize connection method as QSFP requirements

MPO/MTP to LC Fan Out Cable interface multifibre MPO/MTP with discrete single fiber (LC/SC mainly) connectors. Assemblies are typically used to directly interconnect MTP/MPO cassettes, panels or backbone trunk assemblies with the active equipment ports, saving costly data centre rack space and easing fibre management. Replacing traditional MTP/MPO module Fan-Out Assemblies reduce amount of interconnection improving power budget cost

SPECIFICATION

FEATURE

SPECIFICATION

MPO/MTP PATCH CORD

MPO/MTP-SC/LC PATCH CORD

ItemsElite Performance Std Performance

SM MM SM MM

Insertion Loss2F,8F,12F 24F 2F,8F,12F 24F 2F,8F,12F 24F 2F,8F,12F 24F

≤0.35dB ≤0.5dB ≤0.35dB ≤0.7dB ≤0.7dB

Return Loss ≥ 55dB ≥20dB ≥55dB ≥20dB

Durability 500times

Operation temperature - 25℃~ +70 ℃

Fiber Type OS2/OM1/OM2/OM3/OM4

Items SC/LC MTP/MPO(Std) MTP/MPO(Elite)

Insertion Loss

SM MM SM MM SM MM

UPC APC PC 12F,24F 12F,24F 12F 24F 12F,24F

≤0.3dB ≤0.7dB ≤0.35dB ≤0.5dB ≤0.35dB

Return Loss ≥50dB ≥60dB ≥30dB ≥55dB ≥20dB ≥55dB ≥20dB

Durability 500times

Operation temperature -25 ℃~ +70 ℃

Fiber Type OS2/OM1/OM2/OM3/OM4

MPO/MTP - MPO/MTP Patch Cord

MPO - LC Fan - out Patch Cord

MTP- LC Fan - out Patch Cord

Page 42: Table of Contents - Fiber Optic Passive Devices ... · Patch Cord Armored and Mode-conditioning Patch Cord FTTA and FTTH Drop Patch cord MPO/MTP/LC/SC Loopback Patch cord Pigtail

40

FTTH Box & Field Assembly Optical Connector

FEATURE

Field Assembly Optical Connector (FAOC) is a perfect solution for filed working and FTTH connec-tion. It is widely used for where need to quick connection, providing a quick assembly and stable performance. When engineers work in field for installation, maintenance, repair of optical fiber, or FTTH indoor terminate, they can use it easily because it has no epoxy, no polishing.

SPECIFICATION

FIELD ASSEMBLY OPTICAL CONNECTOR

FEATURE

Fiber optic wall outlets are used to terminated drop cable from outdoor to indroor, to realize fiber to the home. Suitable for max 2 fiber splice termination. We could this fibre optic wall outlet box with SC, LC adapter, pigtails pre-assembled.

SPECIFICATION

FTTH BOX

Items

Weight (with cassette)

Fiber Capacity

Operation temperature

FTTH BOX

0.082 kg

2cores

-25℃~ +70℃

Items Single mode Multi mode

Insertion Loss ≤0.3dB ≤0.3dB

Return Loss ≥45dB(PC); ≥55dB(APC) ≥25dB

Insert-pull test 1000 times < 0.3dB

Operation temperature - 45℃~ +70℃

Suit cable 0.9mm, 2.0mm, 3.0mm

1ch FTTH Box 106x80x24mm

2ch FTTH Box 86x86x22.3mm

4ch FTTH Box 100x80x31mm

SC Field Assembly connector

▪ Wall installation,space saving,easily installation ▪ Light weight,high intensity,Good crashworthiness and dustproof▪ Clear management for the patch cord and easily find ▪ ufficient space can be ensure the fiber bending rate

▪ Inside ferrule with fiber stuff and pre-polishing▪ Field installable, quick connection, easy for operation▪ No epoxy, no polishing, no adhesive, no electricity required▪ High performance and high reliability▪ Simply and easy fixed fiber or cable▪ Cable Tensile complied with Telcordia GR-326-CORE