86
Table of Content| Installation Instructions | Heavy Commercial Vehicles | Part 2 (M-Z) General Information: About these instructions / How to use? Change of connections when making use of only DatacliQ ( Navman) Release notes Squarell Flex wiring loom layout Squarell Solid wiring loom layout Vehicle Installion Manuals: o Trucks USA Universal (6 pins Deutsch connector) o Trucks USA Universal (9 pins Deutsch connector) o Mack CH613 & RD688 & Engine Model E7 1998 - 2003 o Mack Granite 2006+ o Mack Pinnacle 2007+ o Mack Vision 2003-2016 o MAN TGA (Euro 3,4) 2000-2007 o MAN TGL (Euro 4,5) 2005-2013 o MAN TGL (Euro 6) 2013+ o MAN TGM I (Euro 4) 2005-2008 o MAN TGM II (Euro 5) 2008-2013 o MAN TGM III (Euro 6) 2013+ o MAN TGS I (Euro 4,5) 2005-2013 o MAN TGS II (Euro 6) 2013+ o MAN TGX I (Euro 4,5) 2007-2013 o MAN TGX II (Euro 6) 2013+ o Mercedes Actros (1st gen MP1) 1998-2002 o Mercedes Actros (1st gen MP2) 2003-2008 o Mercedes Actros (1st gen MP3) 2008-2011 o Mercedes Actros (2nd gen MP4) 2011+ o Mercedes Antos (1st gen) 2012+ o Mercedes Arocs (1st gen) 2013+ o Mercedes Atego (1st gen) 1998-2004 o Mercedes Atego (1st gen Facelift) 2004-2013 o Mercedes Atego (2nd gen) 2013+ o Mercedes Axor (1st gen Series I) 2001-2004 o Mercedes Axor (1st gen Series II) 2004-2011 o Mercedes Axor (1st gen Series III) 2011-2013 o Mercedes Econic (1st gen) 2002-2013 o Mercedes New Econic (2 nd gen) 2013 o Mitsubishi Canter Euro 4 & 5 o Mitsubishi Canter Fuso 2013-2014 o Mitsubishi Fuso EcoHybrid 2012-2014 o Renault Kerax DCI Euro 3,4 2002-2006 o Renault Kerax DXI Euro 4,5,EEV 2006-2013 o Renault C High cab (DTI 11,13) Euro 6 2013+ o Renault C (DTI 8) Euro 6 2013+ o Renault K (DTI 11,13) Euro 6 2013+ o Renault Magnum DCI Euro 3,4 2002-2006 o Renault Magnum DXI Euro 4,5,EEV 2006-2013 o Renault Premium DCI Euro 3,4 2002-2006 o Renault Premium DXI Euro 4,5,EEV 2006-2013 o Renault T High cab (DTI 13) Euro 6 2013+ o Renault T (DTI 11,13) Euro 6 2013+ o Renault Midlum DCI Euro 3,4 2002-2006 o Renault Midlum DXI Euro 4,5,EEV 2006-2013 o Renault D 2m cab (DTI 3) 2013+ o Renault D (DTI 5,8) Euro 6 2013+ o Renault D Wide (DTI 8,11) Euro 6 2013+ o Renault D Acces (DTI 8) Euro 6 2013+ o Scania 4-Series 1995-1999 o Scania 4 Series 2000-2004 o Scania G-Series (1st gen) 2007-2009 o Scania G-Series (1st gen Facelift) 2010+ o Scania P-Series (1st gen) 2005-2009 o Scania P-Series (1st gen Facelift) 2010+ o Scania R-Series (1st gen) 2005-2011 o Scania R-Series (1st gen Facelift) 2012-2016 o Scania R-Series (2nd gen) 2016+ o Scania S-Series (1st gen) 2016+ o Scania T-Series with EDC 1998-2000 o Scania T-Series 2000-2004 o Sinotruk Howo A7 2008-2016 o UD (Nissan Diesel) Quon 2007+ o Volvo FE (1st gen) 2006-2012 o Volvo FE (1st gen Facelift) 2013+ o Volvo FH (Version 98) 1998-2002 o Volvo FH (Version 2) 2002-2012 o Volvo FH (4) Euro 6 2012+ o Volvo FL (1st gen Facelift) 2000-2005 o Volvo FL (2nd gen) 2006-2012 o Volvo FL (2nd gen Facelift) Euro 6 2013+ o Volvo FM (1st gen) 1998-2002 o Volvo FM (2nd gen) 2002-2012 o Volvo FM (2nd gen Facelift) Euro 6 2013+ o Volvo FMX (1st gen) 2010-2012 o Volvo FMX (1st gen Facelift) 2013+ o VW Constellation 2010+ o VW Worker 2003 + o Westernstar 4800 FX 2011+ Checkout all supported parameters on our Vehicle Support Matrix Checkout the release notes of the installation instructions

Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Table of Content| Installation Instructions | Heavy Commercial Vehicles | Part 2 (M-Z)

General Information: About these instructions / How to use? Change of connections when making use of only DatacliQ

(Navman) Release notes Squarell Flex wiring loom layout Squarell Solid wiring loom layout

Vehicle Installion Manuals:o Trucks USA Universal (6 pins Deutsch connector)o Trucks USA Universal (9 pins Deutsch connector)o Mack CH613 & RD688 & Engine Model E7 1998 - 2003o Mack Granite 2006+o Mack Pinnacle 2007+o Mack Vision 2003-2016o MAN TGA (Euro 3,4) 2000-2007o MAN TGL (Euro 4,5) 2005-2013o MAN TGL (Euro 6) 2013+o MAN TGM I (Euro 4) 2005-2008o MAN TGM II (Euro 5) 2008-2013o MAN TGM III (Euro 6) 2013+o MAN TGS I (Euro 4,5) 2005-2013o MAN TGS II (Euro 6) 2013+o MAN TGX I (Euro 4,5) 2007-2013o MAN TGX II (Euro 6) 2013+o Mercedes Actros (1st gen MP1) 1998-2002o Mercedes Actros (1st gen MP2) 2003-2008o Mercedes Actros (1st gen MP3) 2008-2011o Mercedes Actros (2nd gen MP4) 2011+o Mercedes Antos (1st gen) 2012+o Mercedes Arocs (1st gen) 2013+o Mercedes Atego (1st gen) 1998-2004o Mercedes Atego (1st gen Facelift) 2004-2013o Mercedes Atego (2nd gen) 2013+o Mercedes Axor (1st gen Series I) 2001-2004o Mercedes Axor (1st gen Series II) 2004-2011o Mercedes Axor (1st gen Series III) 2011-2013o Mercedes Econic (1st gen) 2002-2013

o Mercedes New Econic (2nd gen) 2013o Mitsubishi Canter Euro 4 & 5o Mitsubishi Canter Fuso 2013-2014 o Mitsubishi Fuso EcoHybrid 2012-2014o Renault Kerax DCI Euro 3,4 2002-2006o Renault Kerax DXI Euro 4,5,EEV 2006-2013o Renault C High cab (DTI 11,13) Euro 6 2013+o Renault C (DTI 8) Euro 6 2013+o Renault K (DTI 11,13) Euro 6 2013+o Renault Magnum DCI Euro 3,4 2002-2006o Renault Magnum DXI Euro 4,5,EEV 2006-2013o Renault Premium DCI Euro 3,4 2002-2006o Renault Premium DXI Euro 4,5,EEV 2006-2013o Renault T High cab (DTI 13) Euro 6 2013+o Renault T (DTI 11,13) Euro 6 2013+o Renault Midlum DCI Euro 3,4 2002-2006o Renault Midlum DXI Euro 4,5,EEV 2006-2013o Renault D 2m cab (DTI 3) 2013+o Renault D (DTI 5,8) Euro 6 2013+o Renault D Wide (DTI 8,11) Euro 6 2013+o Renault D Acces (DTI 8) Euro 6 2013+o Scania 4-Series 1995-1999o Scania 4 Series 2000-2004o Scania G-Series (1st gen) 2007-2009o Scania G-Series (1st gen Facelift) 2010+o Scania P-Series (1st gen) 2005-2009o Scania P-Series (1st gen Facelift) 2010+o Scania R-Series (1st gen) 2005-2011o Scania R-Series (1st gen Facelift) 2012-2016o Scania R-Series (2nd gen) 2016+o Scania S-Series (1st gen) 2016+o Scania T-Series with EDC 1998-2000o Scania T-Series 2000-2004o Sinotruk Howo A7 2008-2016o UD (Nissan Diesel) Quon 2007+ o Volvo FE (1st gen) 2006-2012o Volvo FE (1st gen Facelift) 2013+o Volvo FH (Version 98) 1998-2002

o Volvo FH (Version 2) 2002-2012o Volvo FH (4) Euro 6 2012+o Volvo FL (1st gen Facelift) 2000-2005o Volvo FL (2nd gen) 2006-2012o Volvo FL (2nd gen Facelift) Euro 6 2013+o Volvo FM (1st gen) 1998-2002o Volvo FM (2nd gen) 2002-2012o Volvo FM (2nd gen Facelift) Euro 6 2013+o Volvo FMX (1st gen) 2010-2012o Volvo FMX (1st gen Facelift) 2013+o VW Constellation 2010+o VW Worker 2003+o Westernstar 4800 FX 2011+

Checkout all supported parameters on our Vehicle Support MatrixCheckout the release notes of the installation instructions

Page 2: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

About these instructions | How to Use

About

These instructions are to be used by technically skilled persons. These installation instructions are applicable to Squarell products only. It instructs the installer how to connect Squarell equipment to the vehicle data network and power supply.Squarell makes no representations or warranties, expressed or implied, with respect to the accuracy, completeness or reliability of this document.

Important

Read these instructions carefully and in full, before you proceed installing. Installation of Squarell equipment may only performed by Squarell trained specialists, or under supervision of Squarell.Professional installation equipment and tools are to be used. Ignition key should be switched off before installing Squarell equipment. Country specific rules for installation are to be taken in consideration. Vehicle manufacturer specific rules for installation are to be taken in consideration.All Squarell equipment are complying to E-standards.

Before starting any work: Check if the digital tachograph has NO driver cards inserted. (Let the driver remove the cards)

If you have to un-power the tachograph, please inform the vehicle owner, as the tachograph must be checked by a tacho service station afterwards.

Power connections, ground and fusing

Squarell products are meant to be used in automotive and harsh environments with normal supply voltages of 12 and 24 volts.The power supply can range between 8 and 48 volts, the units are resistant to supply disturbances as described in the E-certification documents.If Squarell products are used in a one-system design, please use 1 fuse for supply power protection and 1 common ground connection for the total system.

Electrical Connections to existing wiring

If electric connections are made to existing wiring looms, please use proper crimping tools. If welding joints are made, observe that welding joints are properly isolated.

CANcliQ and DatacliQ connections

CANcliQ and DatacliQ connections are non-electrical joints to the vehicle network, please observe that the CANcliQ is clamped around undamaged cable wire isolation.

Mounting Squarell devices to the vehicle structure

Use tie wraps or fixing tape to fix the Squarell unit to the structure of the vehicle. Take care that vibration and noise is avoided when operational.

Mounting cables

Please use cable ties to mount Squarell cables to existing wiring looms. Cables must not be mounted under tension. Avoid cable nick when bundling cables together.

Post-installation

General -To test the installation- The Squarell LED is green when ignition is on.If the LED is red, check if the connected equipment (like telematics) is on.Follow the testing routines of the connected equipment.After correct installation, take pictures of the electrical connections to the vehicle and the connected equipment. This pictures can be used as reference of performed work and proper installation.

Technical support

Support: support.squarell.comFax: +31 (0) 252 41 36 29Telephone: +31 (0) 252 42 02 39 (working days 9:00 – 17:00 GMT+1)

Copyright:

All Squarell written manuals, training, presentations and installation instructions are subject to Squarell copyright. Reproduction may only be made for internal training or support purposes. Reproduction for external purposes are only allowed after written approval from Squarell.

How to Use

Select vehicle page (left hand side). The colors on the vehicle page are vehicle colors.Select device and connection (right hand side). The colors on the device page are Squarell colors.

Page 3: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Change of connections when making use of Navcan device

AboutThis additional page is for the use with Navman devices of Squarell Technology.It displays there’s a different connection needed for the use with Navcan, please keep track off this during installation!

CAN LOW

CAN HIGH

ID 180

ID 180 ID 181

can1 can2 J1708ID 280

ID 280

ISOID 190

ID 190

Original

Navcan

Page 4: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Release notes| Installation Instructions | Heavy Commercial Vehicles

Checkout all supported parameters on our Vehicle Support Matrix

Version Description

140728 Initial creation

140729 Table of content added

141016 John Deere 6830, Dennis Eagle Elite 2 & 6, Canter Fuso 2013-2014, Volvo FE & FL Euro 6 added and change on Volvo FH & FM Euro 6.

150416 Added Ford Cargo 2011-2015, Iveco Verti s2015, VW Constellation 2010-2015 and more installation manuals for Isuzu N- and F-series.

Added Scania R-Serie Euro 6 and Nissan UD 2012-2014

150626 John Deere 6830 and Liebherr HS 875 HD moved to Construction & Off-Road group

150804 Renault D-series (DTI 3 engine) 2015 added

151008 Mercedes secondairy CANbus added.

151102 Additional of Flex and Solid wiring looms and the ‘how to use’ page.

160219 Kenworth K404 2006, Kenworth T408 2008, Kenworth K200 2014, Kenworth K104 2006 and Westernstar 4800 FX added.

160817 Chevrolet T-series added

161006 Mercedes New Econic (2nd Gen.) Euro 6 added

170425 Split the Manual in 2 partsAdded special (Navman) DATAcliq connection pageAdded universial connections for USA truck (6 and 9 Deutsch)

170531 Scania R-series (2nd gen) / S-series (1st gen) connection changed toprimary CANbus.

170822 Volvo EU6 main CANbus connection point changed to a more common used pickup.

Page 5: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Not Connected

FLX

12 FLEX–

CA

Ncl

iQca

ble

–R

S23

2 a

nd

/or

CA

Nb

us

ou

tpu

t

80

04

80

03

SOLI

DFL

EX6

63

36

63

16

63

06

62

96

62

86

62

76

62

66

62

56

60

56

60

46

60

36

60

26

60

0

3th

par

ty

USB

RS2

32

CA

N-L

1

CA

N-H

1

GN

D

Po

wer

Version 151102 ENGCopyright © Squarell 2015

BNBK

8612-CQ

OR GR RD

RS232

CANcliQ

YECut to remove K-Line

Pull-up resistor

Cut to remove 1 Terminator in CAN1

RS232

WHBU

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lacK

Po

wer

DataCliq

DataCliq 3th

par

ty

USB

RS2

32

CA

N-L

1

CA

N-H

1

GN

D

Po

wer

TerminatorCut to remove 1 Terminator in CAN1

J1708

Po

we

r &

Gro

un

d

Page 6: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Not Connected

SLD

36

SOLID–

CA

Ncl

iQ c

able

–R

S23

2 a

nd

/or

CA

Nb

us

ou

tpu

t

80

04

80

03

SOLI

DFL

EX6

63

36

63

16

63

06

62

96

62

86

62

76

62

66

62

56

60

56

60

46

60

36

60

26

60

0

3th

par

ty

USB

RS2

32

CA

N-L

1

CA

N-H

1

GN

D

Po

wer

Version 151102 ENGCopyright © Squarell 2015

BNBK

RS232

WHBU

Cut to remove 1 Terminatorin CAN1

TerminatorCut to remove 1 Terminator in CAN1

3th

par

ty

USB

RS2

32

CA

N-L

1

CA

N-H

1

GN

D

Po

wer

CA

Ncl

iQ

Dat

acliQ

1

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lacK

Po

wer

Dat

acliQ

2

WHBU

Po

we

r &

Gro

un

d

Page 7: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Find the Deutsch connector located somewhere in the orange circle. Mostly at the driver side.

J1708

Please be aware this is the front view of the connector!

Untwist Pin A & Pin B wires.

Place the wire of Pin A in the CAN High slot.Place the wire of Pin B in the CAN Low slot.

Close datacliQ (ID280).

Power + Ground

Ground (KL31)Deutsch connector Pin E

Continuous Power (KL30)Deutsch connector Pin C

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

Version 18012016 ENGCopyright © Squarell 2016CQ

ID 280CANbus

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Tru

cks

USA

Un

ive

rsal

(6

pin

s D

eu

tsch

co

nn

ect

or)

J1708

Page 8: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Find the Deutsch connector located somewhere in the orange circle. Mostly at the driver side.

CANbus J1939

Untwist Pin C & Pin D wires.

Place the wire of Pin C in the CAN High slot.Place the wire of Pin D in the CAN Low slot.

Close CANcliQ.

J1708

Untwist Pin F & Pin G wires.

Place the wire of Pin F in the CAN High slot.Place the wire of Pin G in the CAN Low slot.

Close datacliQ (ID280).

Power + Ground

Ground (KL31)Deutsch connector Pin A

Continuous Power (KL30)Deutsch connector Pin B

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

Version 18012016 ENGCopyright © Squarell 2016CQ

CAN LOW

CAN HIGH

CAN LOW

CAN HIGH

ID 280CANbus

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Tru

cks

USA

Un

ive

rsal

(9

pin

s D

eu

tsch

co

nn

ect

or)

J1708

Page 9: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At Driver side (orange arrow) Find the twisted 2 White wires behind the HD-6 OBD connector.

J1708 bus

Untwist 2 White wires,Place White wire on pin B in HighPlace White wire on pin A in LowClose DatacliQ.

Power + Ground

Connections at backside of the OBD connector.

Ground (KL31) :Pin E with Black wires (Black arrow)

Continuous Power (KL30) :Pin C with White wires (Brown arrow)

Power on Ignition (KL15) :Pin D with White wires (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2012

© Squarell 2012

BK

© Squarell 2012

WH

WH WH

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

WH

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Mac

kC

H6

13

/ R

D6

88

/ E

ngi

ne

Mo

de

l E7

19

98

–2

00

2

Page 10: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At Driver side (orange arrow)Remove the lower dashboard cap.

Find the twisted Yellow and Green CANbus wires and twisted 2x White-Orange J1708 wires behind the HD-9 OBD connector.

CANbus

Untwist Green and Yellow wires,Place Yellow wire (pin C) in CAN HighPlace Green wire (pin D) in CAN LowClose CANcliQ.

J1708 busUntwist 2 White-Orange wires,Place White-Orange wire on pin G in HighPlace White-Orange wire on pin F in LowClose DatacliQ.

Power + Ground

Connections at backside of the OBD connector.

Ground (KL31) :Pin A with Grey wires (Grey arrow)

Continuous Power (KL30) :Pin B with White-Orange wires (Red arrow)

Power on Ignition (KL15) :Pin J with White-Orange wires (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2012

© Squarell 2012

YE

GNGN GR

© Squarell 2012

WH/OR

WH/OR

WH/OR WH/OR

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Mac

kG

ran

ite

20

06

+

Page 11: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At Driver side (orange arrow)Remove the lower dashboard cap.

Find the twisted Yellow and Green CANbus wires and twisted 2x White-Orange J1708 wires behind the HD-9 OBD connector.

CANbus

Untwist Green and Yellow wires,Place Yellow wire (pin C) in CAN HighPlace Green wire (pin D) in CAN LowClose CANcliQ.

J1708 busUntwist 2 White-Orange wires,Place White-Orange wire on pin G in HighPlace White-Orange wire on pin F in LowClose DatacliQ.

Power + Ground

Connections at backside of the OBD connector.

Ground (KL31) :Pin A with Grey wires (Grey arrow)

Continuous Power (KL30) :Pin B with White-Orange wires (Red arrow)

Power on Ignition (KL15) :Pin J with White-Orange wires (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2012

© Squarell 2012

YE

GNGN GR

© Squarell 2012

WH/OR

WH/OR

WH/OR WH/OR

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Mac

kP

inac

le2

00

7+

Page 12: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At Driver side (orange arrow)Remove the lower dashboard cap.

Find the twisted Yellow and Green CANbus wires and twisted 2x White-Orange J1708 wires behind the HD-9 OBD connector.

CANbus

Untwist Green and Yellow wires,Place Yellow wire (pin C) in CAN HighPlace Green wire (pin D) in CAN LowClose CANcliQ.

J1708 busUntwist 2 White-Orange wires,Place White-Orange wire on pin G in HighPlace White-Orange wire on pin F in LowClose DatacliQ.

Power + Ground

Connections at backside of the OBD connector.

Ground (KL31) :Pin A with Grey wires (Grey arrow)

Continuous Power (KL30) :Pin B with White-Orange wires (Red arrow)

Power on Ignition (KL15) :Pin J with White-Orange wires (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2012

© Squarell 2012

YE

GNGN GR

© Squarell 2012

WH/OR

WH/OR

WH/OR WH/OR

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Mac

kV

isio

n 2

00

3-2

01

6

Page 13: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideRemove 3 screwsOpen fusebox cap

Find the Blue-Red and Blue-White twisted wires (orange arrow)

CANbus

Untwist Blue-Red and Blue-White wires,Place MAN Blue-Red wire in CAN HighPlace MAN Blue-White wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals with Brown wire. (Brown arrow)Continuous Power (KL30) :Free terminals with white wires (White arrow). Power on Ignition (KL15) :Free terminals with White wires (White arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

© Squarell 2011

WHBL/WH BR

BL/RD

CAN LOW

CAN HIGH

WH

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Version 04062012 ENGCopyright © Squarell 2012 CQ

MA

N T

GA

(Eu

ro 3

,4)

20

00

-20

07

Page 14: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideRemove 3 screwsOpen fusebox cap

Find the Blue-Red and Blue-White twisted wires (orange arrow)

CANbus

Untwist Blue-Red and Blue-White wires,Place MAN Blue-Red wire in CAN HighPlace MAN Blue-White wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals with Brown wire. (Brown arrow)Continuous Power (KL30) :Free terminals with white wires (White arrow). Power on Ignition (KL15) :Free terminals with White wires (White arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

© Squarell 2011

WHBL/WH BR

BL/RD

CAN LOW

CAN HIGH

WH

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Version 04062012 ENGCopyright © Squarell 2012 CQ

MA

N T

GL

(Eu

ro 4

,5)

20

05

-20

08

Page 15: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideClick open fuse box cap and remove the 4 Torque screws so you can slide the fuse box to the side.

Find the Blue-Red and Blue-White twisted wires at the black connector at the left side (orange arrow)

CANbus

Untwist Blue-Red and Blue-White wires in the Black connector at the left side.Place MAN Blue-Red wire in CAN HighPlace MAN Blue-White wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals with Brown wire. (Brown arrow)Continuous Power (KL30) :Free terminals with white wires (White arrow). Power on Ignition (KL15) :Free terminals with White wires (White arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

© Squarell 2014

WH

BL/WHBR

BL/RD

CAN LOW

CAN HIGH

WH

© Squarell 2014

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQVersion 15101014 ENGCopyright © Squarell 2013

MA

N T

GL

(Eu

ro6

) 2

01

3+

Page 16: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideRemove 3 screwsOpen fusebox cap

Find the Blue-Red and Blue-White twisted wires (orange arrow)

CANbus

Untwist Blue-Red and Blue-White wires,Place MAN Blue-Red wire in CAN HighPlace MAN Blue-White wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals with Brown wire. (Brown arrow)Continuous Power (KL30) :Free terminals with white wires (White arrow). Power on Ignition (KL15) :Free terminals with White wires (White arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

© Squarell 2011

WHBL/WH BR

BL/RD

CAN LOW

CAN HIGH

WH

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Version 04062012 ENGCopyright © Squarell 2012 CQ

MA

N T

GM

I(E

uro

4)

20

05

-20

08

Page 17: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideRemove 3 screwsOpen fusebox cap

Find the Blue-Red and Blue-White twisted wires (orange arrow)

CANbus

Untwist Blue-Red and Blue-White wires,Place MAN Blue-Red wire in CAN HighPlace MAN Blue-White wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals with Brown wire. (Brown arrow)Continuous Power (KL30) :Free terminals with white wires (White arrow). Power on Ignition (KL15) :Free terminals with White wires (White arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

© Squarell 2011

WHBL/WH BR

BL/RD

CAN LOW

CAN HIGH

WH

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Version 04062012 ENGCopyright © Squarell 2012 CQ

MA

N T

GM

II(E

uro

5)

20

08-

20

13

Page 18: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideClick open fuse box cap and remove the 4 Torque screws so you can slide the fuse box to the side.

Find the Blue-Red and Blue-White twisted wires at the black connector at the left side (orange arrow)

CANbus

Untwist Blue-Red and Blue-White wires in the Black connector at the left side.Place MAN Blue-Red wire in CAN HighPlace MAN Blue-White wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals with Brown wire. (Brown arrow)Continuous Power (KL30) :Free terminals with white wires (White arrow). Power on Ignition (KL15) :Free terminals with White wires (White arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

© Squarell 2014

WH

BL/WHBR

BL/RD

CAN LOW

CAN HIGH

WH

© Squarell 2014

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQVersion 15101014 ENGCopyright © Squarell 2013

MA

N T

GM

III (

Euro

6)

20

13

+

Page 19: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideRemove 3 screwsOpen fusebox cap

Find the Blue-Red and Blue-White twisted wires (orange arrow)

CANbus

Untwist Blue-Red and Blue-White wires,Place MAN Blue-Red wire in CAN HighPlace MAN Blue-White wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals with Brown wire. (Brown arrow)Continuous Power (KL30) :Free terminals with white wires (White arrow). Power on Ignition (KL15) :Free terminals with White wires (White arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

© Squarell 2011

WHBL/WH BR

BL/RD

CAN LOW

CAN HIGH

WH

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Version 04062012 ENGCopyright © Squarell 2012 CQ

MA

N T

GS

I(Eu

ro 4

,5)

20

05-

20

13

Page 20: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideClick open fuse box cap and remove the 4 Torque screws so you can slide the fuse box to the side.

Find the Blue-Red and Blue-White twisted wires at the black connector at the left side (orange arrow)

CANbus

Untwist Blue-Red and Blue-White wires in the Black connector at the left side.Place MAN Blue-Red wire in CAN HighPlace MAN Blue-White wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals with Brown wire. (Brown arrow)Continuous Power (KL30) :Free terminals with white wires (White arrow). Power on Ignition (KL15) :Free terminals with White wires (White arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

© Squarell 2014

WH

BL/WHBR

BL/RD

CAN LOW

CAN HIGH

WH

© Squarell 2014

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQVersion 15101014 ENGCopyright © Squarell 2013

MA

N T

GS

II (

Euro

6)

20

13

+

Page 21: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideRemove 3 screwsOpen fusebox cap

Find the Blue-Red and Blue-White twisted wires (orange arrow)

CANbus

Untwist Blue-Red and Blue-White wires,Place MAN Blue-Red wire in CAN HighPlace MAN Blue-White wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals with Brown wire. (Brown arrow)Continuous Power (KL30) :Free terminals with white wires (White arrow). Power on Ignition (KL15) :Free terminals with White wires (White arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

© Squarell 2011

WHBL/WH BR

BL/RD

CAN LOW

CAN HIGH

WH

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Version 04062012 ENGCopyright © Squarell 2012 CQ

MA

N T

GX

I(E

uro

4,5

) 2

00

7-2

01

3

Page 22: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideClick open fuse box cap and remove the 4 Torque screws so you can slide the fuse box to the side.

Find the Blue-Red and Blue-White twisted wires at the black connector at the left side (orange arrow)

CANbus

Untwist Blue-Red and Blue-White wires in the Black connector at the left side.Place MAN Blue-Red wire in CAN HighPlace MAN Blue-White wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals with Brown wire. (Brown arrow)Continuous Power (KL30) :Free terminals with white wires (White arrow). Power on Ignition (KL15) :Free terminals with White wires (White arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

© Squarell 2014

WH

BL/WHBR

BL/RD

CAN LOW

CAN HIGH

WH

© Squarell 2014

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQVersion 15101014 ENGCopyright © Squarell 2013

MA

N T

GX

II (

Euro

6)

20

13

+

Page 23: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

CAN LOW

CAN HIGH

Location

At the passenger side open de Fuseboxpanel and remove the fuse box.

CANbus

Untwist the Blue and Yellow wires from the CAN distribution block Located at the strip with connectors with only Yellow and blue wires (see Orange arrow)

Place Blue wire in CAN High slot.Place Yellow wire in CAN Low slot.

Close CANcliQ.

FPS CANbus Fuel level

Find the connector where next to the 2 pairs of yellow and blue twisted wires you will also find a Brown wire with a red tracer and a brown wire with blue tracer. This is the FPS connector. Take the Blue and Yellow wires from this connector.

Place Blue wire in CAN High slot.Place Yellow wire in CAN Low slot.Close DatacliQ

Attention!On the picture the FPS is a purple connector however it could also be a Blue or Grey connector.

Power + Ground

Ground (KL31) :Brown Wire (Brown arrow)

Continuous Power (KL30) :(Red arrow).

Power on Ignition (KL15) :Black wire (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2015 © Squarell 2015

© Squarell 2015

GRYL

BL

© Squarell 2015

CQVersion 13032015 ENGCopyright © Squarell 2015

BK

Me

rce

de

s A

ctro

s(1

stge

n M

P1

) 1

99

8-2

00

2

RD

ID 180CANbus BL

YL

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Page 24: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger side Remove lower dashboard panelwith 6 clipsOpen fuse box panel

X11 Purple connector with Yellow and Blue twisted wires. (Z1 Star point CANbus)(orange arrow)

CANbus

Untwist Yellow and Blue wires,Place Mercedes Blue wire in CAN HighPlace Mercedes Yellow wire in CAN LowClose CANcliQ.

For Direct Connections:Place the wires to the free terminals onRow 1 is CAN Low (yellow)Row 3 is CAN High (blue)

Power + Ground

Connections on the fuse box.

Ground (KL31) :Free terminals on X10 Blue connector (Black arrow)

Continuous Power (KL30) :Free terminals on X15 Grey connector (Red arrow)

Power on Ignition (KL15) :Free terminals on X16 Purple connector (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

RD BK

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BU

YE YE

© Squarell 2011

Important!Squarell Brown on vehicle BlackSquarell Black on vehicle Brown

Version 06022013 ENGCopyright © Squarell 2010 CQ

Me

rce

de

sA

ctro

s(1

stge

n M

P2

) 2

00

3-2

00

8

Page 25: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger side Remove lower dashboard panelwith 6 clipsOpen fuse box panel

X11 Purple connector with Yellow and Blue twisted wires. (Z1 Star point CANbus)(orange arrow)

CANbus

Untwist Yellow and Blue wires,Place Mercedes Blue wire in CAN HighPlace Mercedes Yellow wire in CAN LowClose CANcliQ.

For Direct Connections:Place the wires to the free terminals onRow 1 is CAN Low (yellow)Row 3 is CAN High (blue)

Power + Ground

Connections on the fuse box.

Ground (KL31) :Free terminals on X10 Blue connector (Black arrow)

Continuous Power (KL30) :Free terminals on X15 Grey connector (Red arrow)

Power on Ignition (KL15) :Free terminals on X16 Purple connector (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

RD BK

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BU

YE YE

© Squarell 2011

Important!Squarell Brown on vehicle BlackSquarell Black on vehicle Brown

Version 06022013 ENGCopyright © Squarell 2010 CQ

Me

rce

de

sA

ctro

s(1

stge

n M

P3

) 2

00

8-2

01

1

Page 26: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger side Remove lower dashboard panel with 3 clipsRemove the Silver StripRemove the dashboard cap

Find the Grey Connector with a lot of Green and Blue twisted pair of wires.(orange arrow)

CANbus

Untwist a pair with Green and Blue color,Place Mercedes Blue wire in CAN HighPlace Mercedes green wire in CAN LowClose CANcliQ.

Power + Ground

Connections on the fuse box.

Ground (KL31) :White connector with brown wires (Brown arrow)

Continuous Power (KL30) :Blue connector with red wires (Red arrow)

Power on Ignition (KL15) :Blue connector with black wires (Black arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

Version 18022013 ENGCopyright © Squarell 2011

RDBR

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BU

GN BK

© Squarell 2011

1

3

2

Important!Squarell Brown on vehicle BlackSquarell Black on vehicle Brown

CQ

Me

rce

de

sA

ctro

s(2

nd

gen

MP

4)

20

11

+

Page 27: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger side Remove lower dashboard panel with 3 clipsRemove the Silver StripRemove the dashboard cap

Find the Grey Connector with a lot of Green and Blue twisted pair of wires.(orange arrow)

CANbus

Untwist a pair with Green and Blue color,Place Mercedes Blue wire in CAN HighPlace Mercedes green wire in CAN LowClose CANcliQ.

Power + Ground

Connections on the fuse box.

Ground (KL31) :White connector with brown wires (Brown arrow)

Continuous Power (KL30) :Blue connector with red wires (Red arrow)

Power on Ignition (KL15) :Blue connector with black wires (Black arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

Version 18022013 ENGCopyright © Squarell 2011

RDBR

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BU

GN BK

© Squarell 2011

1

3

2

Important!Squarell Brown on vehicle BlackSquarell Black on vehicle Brown

CQ

Me

rce

de

sA

nto

s(1

stge

n)

20

12

+

Page 28: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger side Remove lower dashboard panel with 3 clipsRemove the Silver StripRemove the dashboard cap

Find the Grey Connector with a lot of Green and Blue twisted pair of wires.(orange arrow)

CANbus

Untwist a pair with Green and Blue color,Place Mercedes Blue wire in CAN HighPlace Mercedes green wire in CAN LowClose CANcliQ.

Power + Ground

Connections on the fuse box.

Ground (KL31) :White connector with brown wires (Brown arrow)

Continuous Power (KL30) :Blue connector with red wires (Red arrow)

Power on Ignition (KL15) :Blue connector with black wires (Black arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

Version 18022013 ENGCopyright © Squarell 2011

RDBR

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BU

GN BK

© Squarell 2011

1

3

2

Important!Squarell Brown on vehicle BlackSquarell Black on vehicle Brown

CQ

Me

rce

de

sA

rocs

(1st

gen

) 2

01

3+

Page 29: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger side Remove lower dashboard panel with 4 clipsRemove upper dashboard panel with 4 clips

Connector with multiple Yellow/Blue twisted wires. (Z1 Star point CANbus)(orange arrow)

CANbus

Place Mercedes Blue wire in CAN HighPlace Mercedes Yellow wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals (Brown arrow).

Continuous Power (KL30) :Free terminals (Red arrow).

Power on Ignition (KL15) :Free terminals (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

Version 06022013 ENGCopyright © Squarell 2010

RD BK

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BU

YE BR

© Squarell 2011 © Squarell 2011© Squarell 2011

Important!Squarell Brown on vehicle BlackSquarell Black on vehicle Brown

CQ

Me

rce

de

sA

tego

(1st

gen

) 1

99

8-2

00

4

Page 30: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger side Remove lower dashboard panel with 4 clipsRemove upper dashboard panel with 4 clips

Connector with multiple Yellow/Blue twisted wires. (Z1 Star point CANbus)(orange arrow)

CANbus

Untwist Yellow and Blue wires,Place Mercedes Blue wire in CAN HighPlace Mercedes Yellow wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals on Grey connector with Brown wires (Brown arrow).

Continuous Power (KL30) :Free terminals on Grey connector with Red wires (Red arrow).

Power on Ignition (KL15) :Free terminals on Grey connector with Black wires (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

RDBK

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BU

YE BR

© Squarell 2011

© Squarell 2011

© Squarell 2011

Important!Squarell Brown on vehicle BlackSquarell Black on vehicle Brown

Version 06022013 ENGCopyright © Squarell 2010 CQ

Me

rce

de

sA

tego

(1st

gen

Fac

elif

t) 2

00

4-2

01

3

Page 31: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger side Remove lower dashboard panel with 4 clipsRemove upper dashboard panel with 4 clips

CANbus distribution block Connector withmultiple Green/Blue twisted wires. (orange arrow)

CANbus

Untwist Green and Blue wires,Place Mercedes Blue wire in CAN HighPlace Mercedes Green wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals on Grey connector with Brown wires (Brown arrow).

Continuous Power (KL30) :Red wire (Red arrow).

Power on Ignition (KL15) :(Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014

RDBK

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BU

GN

BR

© Squarell 2014

© Squarell 2014

© Squarell 2014

Important!Squarell Brown on vehicle BlackSquarell Black on vehicle Brown

Version 26052014 ENGCopyright © Squarell 2010 CQ

Me

rce

de

sA

tego

(2n

dge

n)

20

13

+

Page 32: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger side Remove lower dashboard panel with 4 clipsRemove upper dashboard panel with 4 clips

Connector with multiple Yellow/Blue twisted wires. (Z1 Star point CANbus)(orange arrow)

CANbus

Untwist Yellow and Blue wires,Place Mercedes Blue wire in CAN HighPlace Mercedes Yellow wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals on Grey connector with Brown wires (Brown arrow).

Continuous Power (KL30) :Free terminals on Grey connector with Red wires (Red arrow).

Power on Ignition (KL15) :Free terminals on Grey connector with Black wires (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

RDBK

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BU

YE BR

© Squarell 2011

© Squarell 2011

© Squarell 2011

Important!Squarell Brown on vehicle BlackSquarell Black on vehicle Brown

Version 06022013 ENGCopyright © Squarell 2010 CQ

Me

rce

de

sA

xor

(1st

gen

Se

rie

s I)

20

01

-20

04

Page 33: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger side Remove lower dashboard panel with 4 clipsRemove upper dashboard panel with 4 clips

Connector with multiple Yellow/Blue twisted wires. (Z1 Star point CANbus)(orange arrow)

CANbus

Untwist Yellow and Blue wires,Place Mercedes Blue wire in CAN HighPlace Mercedes Yellow wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals on Grey connector with Brown wires (Brown arrow).

Continuous Power (KL30) :Free terminals on Grey connector with Red wires (Red arrow).

Power on Ignition (KL15) :Free terminals on Grey connector with Black wires (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

RDBK

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BU

YE BR

© Squarell 2011

© Squarell 2011

© Squarell 2011

Important!Squarell Brown on vehicle BlackSquarell Black on vehicle Brown

Version 06022013 ENGCopyright © Squarell 2010 CQ

Me

rce

de

sA

xor

(1st

gen

Se

rie

s II

) 2

00

4-2

01

1

Page 34: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger side Remove lower dashboard panel with 4 clipsRemove upper dashboard panel with 4 clips

Connector with multiple Yellow/Blue twisted wires. (Z1 Star point CANbus)(orange arrow)

CANbus

Untwist Yellow and Blue wires,Place Mercedes Blue wire in CAN HighPlace Mercedes Yellow wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals on Grey connector with Brown wires (Brown arrow).

Continuous Power (KL30) :Free terminals on Grey connector with Red wires (Red arrow).

Power on Ignition (KL15) :Free terminals on Grey connector with Black wires (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

RDBK

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BU

YE BR

© Squarell 2011

© Squarell 2011

© Squarell 2011

Important!Squarell Brown on vehicle BlackSquarell Black on vehicle Brown

Version 06022013 ENGCopyright © Squarell 2010 CQ

Me

rce

de

sA

xor

(1st

gen

Se

rie

s II

I) 2

01

1-2

01

3

Page 35: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

CAN LOW

CAN HIGH

Location

Find the fusebox, located behind the driver seat.

The CAN-bus wires are located behind the fusebox.Find the module with three grey connectors and one purple connector. The CAN-bus wires are located at the purple connector.

Untwist the Yellow and Blue wires.Place the Blue wire in the CAN High slot.Place the Yellow wire in the CAN Low slot.Close the CANcliQ.

Power + Ground

If equipt with OBD connect power and ground on the pins. If not search for a power and ground wire.Ground (KL31) :OBD Pin 4,5Squarell black wire to ground wire.

Continuous Power (KL30) :OBD pin 16Squarell Brown wire to +24V wire.

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2017

© Squarell 2017© Squarell 2017

BL

YL

CQVersion 160707 ENGCopyright © Squarell 2016

Me

rce

de

s Ec

on

ic(1

stge

n)

20

02

-20

13

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Page 36: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

CAN LOW

CAN HIGH

Location

Remove the instrument cluster to get to the CAN wires .

Find the Loom with the twisted Yellow and Blue wires behind the instrument cluster

Untwist the Yellow and Blue wires.Place the Blue wire in the CAN High slot.Place the Yellow wire in the CAN Low slot.Close the CANcliQ.

Power + GroundWire Loom behind the instrument cluster

Ground (KL31) :Brown Wire (Brown arrow).

Continuous Power (KL30) :Red wire (Red arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2016

© Squarell 2016© Squarell 2016

BL

YL

© Squarell 2016

CQVersion 160707 ENGCopyright © Squarell 2016

BR

Me

rce

de

s N

ew E

con

ic(2

nd

gen

)2

01

3+

RD

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Page 37: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Mitsubishi Canter Euro 4 & 5 - Direct Vehicle CANbus

,

Location

At Middle console behind the fuse box.Remove the dashboard caps as in the 1st andthe 2nd picture.

Find the OBD Connector (Orange arrow).Disconnect the OBD connector from its place.

CANbus

At backside of the OBD connector (pin 6 & 14)Connect to the Grey wire in CAN HighConnect to the Orange wire in CAN Low

Power + Ground

Connections at backside of the OBD connector.

Ground (KL31) :OBD Connector pin 4 or pin 5 (Black/White arrow).Continuous Power (KL30) :OBD Connector pin 16 (Pink/Green arrow).Terminal with Red wire behind the fuse boxPower on Ignition (KL15) :Terminal with Green wire behind the fuse box (Green arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

Mit

sub

ish

i Fu

so C

ante

r Eu

ro 4

& 5

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

Version 14122010 ENGCopyright © Squarell 2010

PK/GN

GN

GY

OR

BK/WH

© Squarell 2011 © Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQ

Page 38: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

CAN LOW

CAN HIGH

Location

Remove the lower dashboard cover specified with the (Orange arrow).

Find the CAN connector with the Green and White wire (Orange Arrow).

CANbus

Place the Green wire in the CAN High slot.Place the White wire in the CAN low slot.Close the CANcliQ properly.

Power + GroundConnections at cigarette lighter and OBD connector.

Ground (KL31) :Black wire (Black arrow).

Continuous Power (KL30) :Pin 16 OBD connector (Pink-Blue wire)

Power on Ignition (KL15) :Blue wire (Blue arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014

© Squarell 2014

WHWH

GN

© Squarell 2014

MC

1

CQVersion 06102014 ENGCopyright © Squarell 2014

BK

Mit

sub

ish

i Can

ter

Fuso

20

13

-20

14

-D

ire

ct V

eh

icle

CA

Nb

us

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Page 39: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Mitsubishi Fuso EcoHybrid 2012-2014 - Direct Vehicle CANbus

CAN LOW

CAN HIGH

,

Location

Under the steering wheel close to the OBD connector there are 2 connectors, 1 with Yellow wires and 1 with Blue wires. (See Orange arrow)

Next to the OBD connector there are 2 small connectors. When you slightly remove the cover you will see Blue and Yellow wires.

CANbus

Remove the black wire cover of the wire bundle to make space for a CANcliQ.Place one yellow wire to the CAN high slot and a Blue wire to the CAN low slot.Then properly close the CANcliQ.

Power + Ground

Connections at passenger side fuse box.

Ground (KL31) :Ground at Chassis bolt (see Black arrow).

Continuous Power (KL30) :Continues Power supply at Bolt in fusebox(see red arrow KL 30)

Power on Ignition (KL15) :Power at ignition made at the Fuse (Red arrow KL 15).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

Mit

sub

ish

i Fu

so E

coH

ybri

d2

01

2-2

01

4 -

Dir

ect

Ve

hic

le C

AN

bu

s

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014

© Squarell 2014

Version 07072014 ENGCopyright © Squarell 2014

BK

YW

RD KL30RD KL15

© Squarell 2014 © Squarell 2014

MFC

2

CQ

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BL

Page 40: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen 2 locks, remove dashboard capRemove lower dashboard panel

VECU on right side of fuse box. (orangearrow)

CANbus

Untwist Blue and Yellow wires, Place Blue wire in CAN Low slotPlace Yellow wire in CAN High slotClose CANcliQ.

Power + Ground

Connections on connector panel

Ground (KL31) :Terminal as in picture (Black arrow)

Continuous Power (KL30) :Terminal as in picture (Red arrow)

Power on Ignition (KL15) :Terminal as in picture (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

This vehicle type is not supporting the Total Fuel Used, the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2012© Squarell 2012

Version 04062012 ENGCopyright © Squarell 2012

RD BK YEBL

CAN LOW

CAN HIGH

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BK YE

© Squarell 2012

© Squarell 2012

CQ

Re

nau

lt K

era

xD

CI E

uro

3,4

20

02-

20

06

Page 41: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen 2 locks, remove dashboard capRemove lower dashboard panel

Find the VECU behind the fuse box. (orange arrow)

CANbus

Untwist Green and Orange wires, Place Green wire in CAN Low slotPlace Orange wire in CAN High slotClose CANcliQ.

J1708 bus

Untwist Brown and Orange wires, Place Brown wire in High slotPlace Orange wire in Low slotClose DatacliQ.

Power + Ground

Connections on the Brown Body Builder PB1 connector

Ground (KL31) :Pin 1, or Pin 21 (Black arrow)

Continuous Power (KL30) :Pin 30 (Red arrow)

Power on Ignition (KL15) :Pin 2 (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, Engine Coolant Temperature and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation. The Engine Coolant Temperature and the Fuel Level can only be supported with a 6628-31 J1708 Diode or FLX12 Flex .

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

BRYEBKGNOG

CAN LOW

CAN HIGH

© Squarell 2011

© Squarell 2011

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BR

OR

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Re

nau

lt K

era

xD

XIE

uro

4,5

,EEV

20

06

-20

13

Page 42: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Middle Console under the rubber cover, you will find the fuse box. Open the Fuse box cover with the 2 clips.

Find the black and white connector with the orange brace at the top right side of the fuse box.(orange arrow)

CANbus

Untwist Yellow and green wires, 2nd Pair from the left in the connector!Place Green wire in CAN Low slotPlace Yellow wire in CAN High slotClose CANcliQ.

Power + Ground

Several options

Ground (KL31) :Terminal as in picture (White arrow)

Continuous Power (KL30) :Terminal as in picture (Red arrow)Power supply

Power on Ignition (KL15) :Terminal as in picture (Red arrow)Cigarette lighter

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

This vehicle type is not supporting the Total Fuel Used, the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

Version 04022014 ENGCopyright © Squarell 2014

RD

WH

YEGN

CAN LOW

CAN HIGH

RD

© Squarell 2014

© Squarell 2014

CQ

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Re

nau

lt C

Hig

h c

ab(D

TI 1

1,1

3)

Euro

6 2

01

3+

Page 43: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Middle Console under the rubber cover, you will find the fuse box. Open the Fuse box cover with the 2 clips.

Find the black and white connector with the orange brace at the top right side of the fuse box.(orange arrow)

CANbus

Untwist Yellow and green wires, 2nd Pair from the left in the connector!Place Green wire in CAN Low slotPlace Yellow wire in CAN High slotClose CANcliQ.

Power + Ground

Several options

Ground (KL31) :Terminal as in picture (White arrow)

Continuous Power (KL30) :Terminal as in picture (Red arrow)Power supply

Power on Ignition (KL15) :Terminal as in picture (Red arrow)Cigarette lighter

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

This vehicle type is not supporting the Total Fuel Used, the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

Version 04022014 ENGCopyright © Squarell 2014

RD

WH

YEGN

CAN LOW

CAN HIGH

RD

© Squarell 2014

© Squarell 2014

CQ

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Re

nau

lt C

(D

TI 8

) Eu

ro 6

20

13

+

Page 44: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Middle Console under the rubber cover, you will find the fuse box. Open the Fuse box cover with the 2 clips.

Find the black and white connector with the orange brace at the top right side of the fuse box.(orange arrow)

CANbus

Untwist Yellow and green wires, 2nd Pair from the left in the connector!Place Green wire in CAN Low slotPlace Yellow wire in CAN High slotClose CANcliQ.

Power + Ground

Several options

Ground (KL31) :Terminal as in picture (White arrow)

Continuous Power (KL30) :Terminal as in picture (Red arrow)Power supply

Power on Ignition (KL15) :Terminal as in picture (Red arrow)Cigarette lighter

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

This vehicle type is not supporting the Total Fuel Used, the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

Version 04022014 ENGCopyright © Squarell 2014

RD

WH

YEGN

CAN LOW

CAN HIGH

RD

© Squarell 2014

© Squarell 2014

CQ

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Re

nau

lt K

(D

TI 1

1,1

3)

Euro

6 2

01

3+

Page 45: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Passenger side, middle of cabOpen 2 locks, remove dashboard capRemove dashboard panel

VECU at lower plate (orange arrow)

CANbus

Untwist Yellow and Blue wires, Place Blue wire in CAN Low slotPlace Yellow wire in CAN High slotClose CANcliQ.

Power + Ground

Connections on fuse box

Ground (KL31) :Terminal as in picture (Black arrow)

Continuous Power (KL30) :Terminal as in picture (Red arrow)

Power on Ignition (KL15) :Terminal as in picture (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

This vehicle type is not supporting the Total Fuel Used, the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

Version 22032011 ENGCopyright © Squarell 2011

RDBKYEBL

CAN LOW

CAN HIGH

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

YE

© Squarell 2011

© Squarell 2011

CQ

Re

nau

lt M

agn

um

DC

I Eu

ro 3

,4 2

00

2-2

00

6

Page 46: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen 2 locks, remove dashboard capRemove lower dashboard panel

Find the VECU behind the fuse box. (orange arrow)

CANbus

Untwist Green and Orange wires, Place Green wire in CAN Low slotPlace Orange wire in CAN High slotClose CANcliQ.

J1708 bus

Untwist Brown and Orange wires, Place Brown wire in High slotPlace Orange wire in Low slotClose DatacliQ.

Power + Ground

Connections on the Brown Body Builder PB1 connector

Ground (KL31) :Pin 1, or Pin 21 (Black arrow)

Continuous Power (KL30) :Pin 30 (Red arrow)

Power on Ignition (KL15) :Pin 2 (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, Engine Coolant Temperature and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation. The Engine Coolant Temperature and the Fuel Level can only be supported with a 6628-31 J1708 Diode or FLX12 Flex .

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

BRYEBKGNOG

CAN LOW

CAN HIGH

© Squarell 2011

© Squarell 2011

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BR

OR

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Re

nau

lt M

agn

um

DX

IEu

ro 4

,5,E

EV 2

00

6-2

01

3

Page 47: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen 2 locks, remove dashboard capRemove lower dashboard panel

VECU on right side of fuse box. (orangearrow)

CANbus

Untwist Blue and Yellow wires, Place Blue wire in CAN Low slotPlace Yellow wire in CAN High slotClose CANcliQ.

Power + Ground

Connections on connector panel

Ground (KL31) :Terminal as in picture (Black arrow)

Continuous Power (KL30) :Terminal as in picture (Red arrow)

Power on Ignition (KL15) :Terminal as in picture (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

This vehicle type is not supporting the Total Fuel Used, the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2012© Squarell 2012

Version 04062012 ENGCopyright © Squarell 2012

RD BK YEBL

CAN LOW

CAN HIGH

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BK YE

© Squarell 2012

© Squarell 2012

CQ

Re

nau

lt P

rem

ium

DC

I Eu

ro3

,4 2

00

2-2

00

6

Page 48: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen 2 locks, remove dashboard capRemove lower dashboard panel

Find the VECU behind the fuse box. (orange arrow)

CANbus

Untwist Green and Orange wires, Place Green wire in CAN Low slotPlace Orange wire in CAN High slotClose CANcliQ.

J1708 bus

Untwist Brown and Orange wires, Place Brown wire in High slotPlace Orange wire in Low slotClose DatacliQ.

Power + Ground

Connections on the Brown Body Builder PB1 connector

Ground (KL31) :Pin 1, or Pin 21 (Black arrow)

Continuous Power (KL30) :Pin 30 (Red arrow)

Power on Ignition (KL15) :Pin 2 (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, Engine Coolant Temperature and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation. The Engine Coolant Temperature and the Fuel Level can only be supported with a 6628-31 J1708 Diode or FLX12 Flex .

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

BRYEBKGNOG

CAN LOW

CAN HIGH

© Squarell 2011

© Squarell 2011

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BR

OR

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Re

nau

lt P

rem

iun

DX

IEu

ro 4

,5,E

EV 2

00

6-2

01

3

Page 49: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Middle Console under the rubber cover, you will find the fuse box. Open the Fuse box cover with the 2 clips.

Find the black and white connector with the orange brace at the top right side of the fuse box.(orange arrow)

CANbus

Untwist Yellow and green wires, 2nd Pair from the left in the connector!Place Green wire in CAN Low slotPlace Yellow wire in CAN High slotClose CANcliQ.

Power + Ground

Several options

Ground (KL31) :Terminal as in picture (White arrow)

Continuous Power (KL30) :Terminal as in picture (Red arrow)Power supply

Power on Ignition (KL15) :Terminal as in picture (Red arrow)Cigarette lighter

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

This vehicle type is not supporting the Total Fuel Used, the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

Version 04022014 ENGCopyright © Squarell 2014

RD

WH

YEGN

CAN LOW

CAN HIGH

RD

© Squarell 2014

© Squarell 2014

CQ

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Re

nau

lt T

Hig

h c

ab (

DTI

13

) Eu

ro 6

20

13

+

Page 50: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Middle Console under the rubber cover, you will find the fuse box. Open the Fuse box cover with the 2 clips.

Find the black and white connector with the orange brace at the top right side of the fuse box.(orange arrow)

CANbus

Untwist Yellow and green wires, 2nd Pair from the left in the connector!Place Green wire in CAN Low slotPlace Yellow wire in CAN High slotClose CANcliQ.

Power + Ground

Several options

Ground (KL31) :Terminal as in picture (White arrow)

Continuous Power (KL30) :Terminal as in picture (Red arrow)Power supply

Power on Ignition (KL15) :Terminal as in picture (Red arrow)Cigarette lighter

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

This vehicle type is not supporting the Total Fuel Used, the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

Version 04022014 ENGCopyright © Squarell 2014

RD

WH

YEGN

CAN LOW

CAN HIGH

RD

© Squarell 2014

© Squarell 2014

CQ

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Re

nau

lt T

(D

TI1

1,1

3)

Euro

6 2

01

3+

Page 51: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen 2 locks, remove dashboard capRemove lower dashboard panel

VECU on left side of fuse box. (orangearrow)

CANbus

Untwist 2 Yellow wires,Place the Yellow wires in CANcliQ as given in the picture. Close CANcliQ.

Power + Ground

Connections by fuse box

Ground (KL31) :Terminal as in picture (Black arrow)

Continuous Power (KL30) :Terminal as in picture (Red arrow)

Power on Ignition (KL15) :

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

Version 22032011 ENGCopyright © Squarell 2011

RD

YE

YE

CAN LOW

CAN HIGH

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

BK

© Squarell 2011

© Squarell 2011

CAN H

CAN L

CQ

Re

nau

lt M

idlu

mD

CI

Euro

3,4

20

02

-20

06

Page 52: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen 2 locks, remove dashboard capRemove lower dashboard panel

Find the VECU on right side of fuse box. (orange arrow)

CANbus

Untwist Green and Orange wires, Place Orange wire in CAN High slotPlace Green wire in CAN Low slotClose CANcliQ.

J1708 bus Untwist Brown and Orange wires, Place Brown wire in High slotPlace Orange wire in Low slotClose DatacliQ.

Power + Ground

Connections on the Brown Body Builder PB1 connector (Purple arrow)

Ground (KL31):Pin 1, or Pin 21 (black arrow)

Continuous Power (KL30):Pin 30 (Red arrow)

Power on Ignition (KL15):Pin 2 (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, Engine Coolant Temperature and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation. The Engine Coolant Temperature and the Fuel Level can only be supported with a 6628-31 J1708 Diode or FLX12 Flex .

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

BR

RDBK

YEOR

GNOR

CAN LOW

CAN HIGH

© Squarell 2011

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

© Squarell 2011

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Re

nau

lt M

idlu

mD

XI

Euro

4,5

,EEV

20

06

-20

13

Page 53: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Renault Maxity 2007-2011

CAN LOW

CAN HIGH

Location

At Driver side, under the dashboard on left Find the OBD Connector (Orange arrow).Disconnect the OBD connector from its place.

CANbus

Untwist wires at backside of the OBD connector (pin 6 & 14)Place Blue wire in CAN HighPlace Pink wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of the OBD connector.

Ground (KL31) :OBD Connector pin 4 and pin 5 (Black arrow).

Continuous Power (KL30) :OBD Connector pin 16 (Red arrow).

Warning! CANcliQ closes only once. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. Warning! To receive the Engine Speed parameter, you have to connect to OBD connector wire to wire instead of CANcliQ.

Re

nau

lt D

2m

cab

20

13

+

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2013

© Squarell 2013

Version 16052013 ENGCopyright © Squarell 2013

RD

BU

PK

BK

© Squarell 2013

© Squarell 2013

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQ

Page 54: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At the passenger side open up the cover with 2 plastic clips.

In the fuse box at the right side, you will find the Renault CAN controller.

CANbus

Untwist the Yellow and Green wire from the 4 pin connector between the green and blue connector.

Place the Yellow wire in the CAN High slot.Place the Green wire in the CAN low slot.Close the CANcliQ properly.

Power + Ground

Ground (KL31) :White wire (White arrow).

Continuous Power (KL30) :Red wire(Red arrow).

Power on Ignition (KL15) :Black wire (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

WH

YL

GN

RD

© Squarell 2014

CQVersion 16102014 ENGCopyright © Squarell 2014

BK

Re

nau

lt D

(D

TI 5

,8)

Euro

6 2

01

3+

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Page 55: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At the passenger side open up the cover with 2 plastic clips.

In the fuse box at the right side, you will find the Renault CAN controller.

CANbus

Untwist the Yellow and Green wire from the 4 pin connector between the green and blue connector.

Place the Yellow wire in the CAN High slot.Place the Green wire in the CAN low slot.Close the CANcliQ properly.

Power + Ground

Ground (KL31) :White wire (White arrow).

Continuous Power (KL30) :Red wire(Red arrow).

Power on Ignition (KL15) :Black wire (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

WH

YL

GN

RD

© Squarell 2014

CQVersion 16102014 ENGCopyright © Squarell 2014

BK

Re

nau

lt D

Wid

e (

DTI

8,1

1)

Euro

6 2

01

3+

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Page 56: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At the passenger side open up the cover with 2 plastic clips.

In the fuse box at the right side, you will find the Renault CAN controller.

CANbus

Untwist the Yellow and Green wire from the 4 pin connector between the green and blue connector.

Place the Yellow wire in the CAN High slot.Place the Green wire in the CAN low slot.Close the CANcliQ properly.

Power + Ground

Ground (KL31) :White wire (White arrow).

Continuous Power (KL30) :Red wire(Red arrow).

Power on Ignition (KL15) :Black wire (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

WH

YL

GN

RD

© Squarell 2014

CQVersion 16102014 ENGCopyright © Squarell 2014

BK

Re

nau

lt D

Acc

es

(DTI

8)

Euro

6 2

01

3+

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Page 57: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen fuseboxRemove 2 screwsTurn open Fusebox

CANbus

Find in the middle of the area under need the fuse box the Black connector with twisted Grey and Blue wires.

Untwist Grey and Blue wires. place Scania Blue wire in CAN Highplace Scania Grey wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals. (black arrow)

Continuous Power (KL30) :Fuse location number 40/41 (Red arrow).

Power on Ignition (KL15) :Fuse location number 44/45 (Green arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Vehicle Distance (Odometer), Total Fuel Used and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Vehicle Distance (Odometer) and the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

Version 22032011 ENGCopyright © Squarell 2011

GR RD GNBKBL

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CAN LOW

CAN HIGH

© Squarell 2011

CQ

Scan

ia 4

-Se

rie

s 1

99

5-1

99

9

Page 58: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen fuseboxRemove 2 screwsTurn open Fusebox

CANbus

Find in the middle of the area under need the fuse box the Black connector with twisted Grey and Blue wires.

Untwist Grey and Blue wires. place Scania Blue wire in CAN Highplace Scania Grey wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals. (black arrow)

Continuous Power (KL30) :Fuse location number 40/41 (Red arrow).

Power on Ignition (KL15) :Fuse location number 44/45 (Green arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Vehicle Distance (Odometer), Total Fuel Used and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Vehicle Distance (Odometer) and the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

Version 22032011 ENGCopyright © Squarell 2011

GR RD GNBKBL

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CAN LOW

CAN HIGH

© Squarell 2011

CQ

Scan

ia 4

-Se

rie

s 2

00

0-2

00

4

Page 59: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen fuseboxRemove 2 screwsTurn open Fusebox

Blue connector at door side with twisted Yellow and White wires. Connector can be hidden inside wiring loom.

CANbus

Untwist White and Yellow wires,Place Scania Yellow wire in CAN High slotPlace Scania White wire in CAN Low slotClose CANcliQ.

For Direct Connections: Unlock connector slide by a screwdriver at orange arrow and place the wires to the free terminal onColumn 1 to 3 CAN Low (white)Column 5 to 7 CAN High (yellow)

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals. (black arrow)

Continuous Power (KL30) :Free terminals with Red wires (Red arrow).

Power on Ignition (KL15) :Free terminals with Green wires (Green arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

Version 18022013 ENGCopyright © Squarell 2012

WH RDGN BKYE

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CAN LOW

CAN HIGH

© Squarell 2011© Squarell 2011 © Squarell 2011

1 7

CQ

Scan

ia G

-Se

rie

s(1

stge

n)

20

07

-20

09

Page 60: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen fuseboxRemove 2 screwsTurn open Fusebox

Blue connector at door side with twisted Yellow and White wires. Connector can be hidden inside wiring loom.

CANbus

Untwist White and Yellow wires,Place Scania Yellow wire in CAN High slotPlace Scania White wire in CAN Low slotClose CANcliQ.

*Any White or Yellow can be used as they are all connected in the connector.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals. (black arrow)

Continuous Power (KL30) :Free terminals with Red wires (Red arrow).

Power on Ignition (KL15) :Free terminals with Green wires (Green arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

Version 18022013 ENGCopyright © Squarell 2012

WH RDGN BKYE

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CAN LOW

CAN HIGH

© Squarell 2011© Squarell 2011 © Squarell 2011

CQ

Scan

ia G

-Se

rie

s (1

stge

n F

ace

lift)

20

10

+

Page 61: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen fuseboxRemove 2 screwsTurn open Fusebox

Blue connector at door side with twisted Yellow and White wires. Connector can be hidden inside wiring loom.

CANbus

Untwist White and Yellow wires,Place Scania Yellow wire in CAN High slotPlace Scania White wire in CAN Low slotClose CANcliQ.

For Direct Connections: Unlock connector slide by a screwdriver at orange arrow and place the wires to the free terminal onColumn 1 to 3 CAN Low (white)Column 5 to 7 CAN High (yellow)

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals. (black arrow)

Continuous Power (KL30) :Free terminals with Red wires (Red arrow).

Power on Ignition (KL15) :Free terminals with Green wires (Green arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

Version 18022013 ENGCopyright © Squarell 2012

WH RDGN BKYE

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CAN LOW

CAN HIGH

© Squarell 2011© Squarell 2011 © Squarell 2011

1 7

CQ

Scan

ia P

-Se

rie

s(1

stge

n)

20

05

-20

09

Page 62: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen fuseboxRemove 2 screwsTurn open Fusebox

Blue connector at door side with twisted Yellow and White wires. Connector can be hidden inside wiring loom.

CANbus

Untwist White and Yellow wires,Place Scania Yellow wire in CAN High slotPlace Scania White wire in CAN Low slotClose CANcliQ.

*Any White or Yellow can be used as they are all connected in the connector.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals. (black arrow)

Continuous Power (KL30) :Free terminals with Red wires (Red arrow).

Power on Ignition (KL15) :Free terminals with Green wires (Green arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

Version 18022013 ENGCopyright © Squarell 2012

WH RDGN BKYE

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CAN LOW

CAN HIGH

© Squarell 2011© Squarell 2011 © Squarell 2011

CQ

Scan

ia P

-Se

rie

s (1

stge

n F

ace

lift)

20

10

+

Page 63: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen fuseboxRemove 2 screwsTurn open Fusebox

Blue connector at door side with twisted Yellow and White wires. Connector can be hidden inside wiring loom.

CANbus

Untwist White and Yellow wires,Place Scania Yellow wire in CAN High slotPlace Scania White wire in CAN Low slotClose CANcliQ.

For Direct Connections: Unlock connector slide by a screwdriver at orange arrow and place the wires to the free terminal onColumn 1 to 3 CAN Low (white)Column 5 to 7 CAN High (yellow)

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals. (black arrow)

Continuous Power (KL30) :Free terminals with Red wires (Red arrow).

Power on Ignition (KL15) :Free terminals with Green wires (Green arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

Version 18022013 ENGCopyright © Squarell 2012

WH RDGN BKYE

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CAN LOW

CAN HIGH

© Squarell 2011© Squarell 2011 © Squarell 2011

1 7

CQ

Scan

ia R

-Se

rie

s(1

stge

n)

20

05

-20

11

Page 64: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger side open up the dashboard and remove the two screws of the fuse panel. Cut the required tie wraps so you are able to lift out the fuse panel.

After the installation replace the removed tie wraps.

(Deep) in the right corner you will find the Blue CAN distribution block with the Yellow and white wires and a blue CAN distribution with White and Green twisted wires.

CANbus

Untwist Yellow and White wires,Place Scania Yellow wire in CAN High slotPlace Scania White wire in CAN Low slotClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals. (black arrow)

Continuous Power (KL30) :Free terminals with Red wires (Red arrow).

Power on Ignition (KL15) :Free terminals with Green wires (Green arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2015

Version 150421ENGCopyright © Squarell 2015

WH RDGN BK

YE

CAN LOW

CAN HIGH

© Squarell 2015

© Squarell 2015© Squarell 2015

CQ

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Scan

ia R

-Se

rie

s (1

stge

n F

ace

lift)

20

12

-20

16

Page 65: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Find the CAN-bus wires at the passenger side. Located behind the fusebox. Which is behind the dashboard cover.

Remove the dashboard cover and fusebox to find the wiring loom at the left side, that contains a yellow and white twisted pair of wires, with a grey ground wire.

CANbus

Untwist the Yellow and White wires.

Place the Yellow wire in the CAN High Slot.Place the White wire in the CAN Low slot.Close CANcliQ.

Power + GroundConnections in OBD connector

Ground (KL31) :OBD connector pin 4 and pin 5

Continuous Power (KL30) :Pin 16 OBD connector

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2017 © Squarell 2017© Squarell 2017 © Squarell 2017

CQVersion 160707 ENGCopyright © Squarell 2016

Scan

ia R

-se

rie

s (2

nd

gen

) 2

01

6+

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

YL

WH

Page 66: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Find the CAN-bus wires at the passenger side. Located behind the fusebox. Which is behind the dashboard cover.

Remove the dashboard cover and fusebox to find the wiring loom at the left side, that contains a yellow and white twisted pair of wires, with a grey ground wire.

CANbus

Untwist the Yellow and White wires.

Place the Yellow wire in the CAN High Slot.Place the White wire in the CAN Low slot.Close CANcliQ.

Power + GroundConnections in OBD connector

Ground (KL31) :OBD connector pin 4 and pin 5

Continuous Power (KL30) :Pin 16 OBD connector

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2017 © Squarell 2017© Squarell 2017 © Squarell 2017

CQVersion 160707 ENGCopyright © Squarell 2016

Scan

ia S

-se

rie

s (1

stge

n)

20

16

+

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

YL

WH

Page 67: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen fuseboxRemove 2 screwsTurn open Fusebox

CANbus

Find in the middle of the area under need the fuse box the Black connector with twisted Grey and Blue wires.

Untwist Grey and Blue wires. place Scania Blue wire in CAN Highplace Scania Grey wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals. (black arrow)

Continuous Power (KL30) :Fuse location number 40/41 (Red arrow).

Power on Ignition (KL15) :Fuse location number 44/45 (Green arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Vehicle Distance (Odometer), Total Fuel Used and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Vehicle Distance (Odometer) and the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

Version 22032011 ENGCopyright © Squarell 2011

GR RD GNBKBL

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CAN LOW

CAN HIGH

© Squarell 2011

CQ

Scan

ia T

-Se

rie

s w

ith

ED

C 1

99

8-2

00

0

Page 68: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen fuseboxRemove 2 screwsTurn open Fusebox

CANbus

Find in the middle of the area under need the fuse box the Black connector with twisted Grey and Blue wires.

Untwist Grey and Blue wires. place Scania Blue wire in CAN Highplace Scania Grey wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31) :Free terminals. (black arrow)

Continuous Power (KL30) :Fuse location number 40/41 (Red arrow).

Power on Ignition (KL15) :Fuse location number 44/45 (Green arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Vehicle Distance (Odometer), Total Fuel Used and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Vehicle Distance (Odometer) and the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

Version 22032011 ENGCopyright © Squarell 2011

GR RD GNBKBL

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CAN LOW

CAN HIGH

© Squarell 2011

CQ

Scan

ia T

-Se

rie

s 2

00

0-2

00

4

Page 69: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideRemove below Dashboard cap.

Find in the middle of the area under need the dashboard ECU with twisted Blue-white and Blue-Yellow wires (Orange arrow)

CANbus

Untwist Blue-White and Blue-Yellow wires. place Blue-White wire in CAN High slotplace Blue-Yellow wire in CAN Low slotClose CANcliQ.

Power + Ground

Connections under need the triangular shaped dashboard cap (purple arrow)

Ground (KL31) :Black wire (black arrow)

Continuous Power (KL30) :Terminal with Red (Red arrow)

Power on Ignition (KL15) :Terminal with Brown (Brown arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2012© Squarell 2012

Version 22032011 ENGCopyright © Squarell 2011

BL/YERD

BK

BL/WH

CAN LOW

CAN HIGH

© Squarell 2012

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

© Squarell 2012

BR

CQ

Sin

otr

uk

Ho

wo

A7

20

08

-20

16

Page 70: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Open the middle console under the instrument cluster.

Remove the ignition key.Then remove the four pins connector with the Green/Yellow and Red/White paired wires.

CANbus

Untwist the Yellow & Green twisted wires from the black controller.Place the Yellow wire in the CAN High Slot.Place the Green wire in the CAN Low slot.Close CANcliQ).

J1708 BusUntwist Red & White wirePlace Red wire in CAN High slot.Place White wire in CAN Low slot.Close DatacliQ (ID280).

Power + Ground

Connections at wire looms near controller.

Ground (KL31)To chassis bolt at ECU.

Continuous Power (KL30)Continuous 24 volt power supply.

Power on Ignition (KL15)Not specified on the picture but easily to be found with a multimeter.

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2015

© Squarell 2015

Version 12052015 ENGCopyright © Squarell 2015

GN

© Squarell 2015

CQ

© Squarell 2015

YL

ID 280CANbus

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

RD

GY

UD

(N

issa

n D

iese

l) Q

uo

n2

00

7+

Page 71: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen 2 locks, remove dashboard capRemove lower dashboard panel

Find the VECU on right side of fuse box. (orange arrow)

CANbus

Untwist Green and Orange wires, Place Orange wire in CAN High slotPlace Green wire in CAN Low slotClose CANcliQ.

J1708 bus Untwist Brown and Orange wires, Place Brown wire in High slotPlace Orange wire in Low slotClose DatacliQ.

Power + Ground

Connections on the Brown Body Builder PB1 connector (Purple arrow)

Ground (KL31):Pin 1, or Pin 21 (black arrow)

Continuous Power (KL30):Pin 30 (Red arrow)

Power on Ignition (KL15):Pin 2 (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, Engine Coolant Temperature and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation. The Engine Coolant Temperature and the Fuel Level can only be supported with a 6628-31 J1708 Diode or FLX12 Flex .

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

BR

RDBK

YEOR

GNOR

CAN LOW

CAN HIGH

© Squarell 2011

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

© Squarell 2011

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Vo

lvo

FE

(1st

gen

) 2

00

6-2

01

2

Page 72: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At the passenger side open up the cover with 2 plastic clips.

In the fuse box at the right side, you will find the Volvo CAN controller.

CANbus

Untwist the Yellow and Green wire from the 4 pin connector between the green and blue connector.

Place the Yellow wire in the CAN High slot.Place the Green wire in the CAN low slot.Close the CANcliQ properly.

Power + Ground

Ground (KL31) :White wire (White arrow).

Continuous Power (KL30) :Red wire(Red arrow).

Power on Ignition (KL15) :Black wire (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

WH

YL

GN

RD

© Squarell 2014

CQVersion 16102014 ENGCopyright © Squarell 2014

BK

Vo

lvo

FE

(1st

gen

Fac

elif

t) E

uro

6 2

01

3+

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Page 73: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Remove screws at extractable cup holderOpen triangular shaped upper dashboard panel

Remove 4 screws of fuse boxOpen fuse box compartmentFind the VECU under the fuse box

CANbus

Untwist Green and Yellow wires, Place Yellow wire in CAN High slotPlace Green wire in CAN Low slotClose CANcliQ.

J1708 bus (DatacliQ)Untwist Grey and Orange wires, Place Orange wire in High slotPlace Grey wire in low slotClose DatacliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31)Green connector with white wires (White arrow)

Continuous Power (KL30)Free terminals “from 50 to 54” (Red arrow).

Power on Ignition (KL15)Free terminals “from 55 to 62” (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, Engine Coolant Temperature and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation. The Engine Coolant Temperature and the Fuel Level can only be supported with a 6628-31 J1708 Diode or FLX12 Flex .

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

© Squarell 2011

RDBKWHOG GY GR YE

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Vo

lvo

FH

(V

ers

ion

98

) 1

99

8-2

00

2

Page 74: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Remove screws at extractable cup holderOpen triangular shaped upper dashboard panel

Remove 4 screws of fuse boxOpen fuse box compartmentFind the VECU under the fuse box

CANbus

Untwist Green and Yellow wires, Place Yellow wire in CAN High slotPlace Green wire in CAN Low slotClose CANcliQ.

J1708 bus (DatacliQ)Untwist Grey and Orange wires, Place Orange wire in High slotPlace Grey wire in low slotClose DatacliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31)Green connector with white wires (White arrow)

Continuous Power (KL30)Free terminals “from 50 to 54” (Red arrow).

Power on Ignition (KL15)Free terminals “from 55 to 62” (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, Engine Coolant Temperature and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation. The Engine Coolant Temperature and the Fuel Level can only be supported with a 6628-31 J1708 Diode or FLX12 Flex .

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

© Squarell 2011

RDBKWHOG GY GR YE

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Vo

lvo

FH

(V

ers

ion

2)

20

02

-20

12

Page 75: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Open up the dashboard by removing the top cover and the side cover at the passenger side to get access to the VMCU(Vehicle Master Control Unit).

Main CANbus

Find the twisted Green and Yellow wires in the blue connector code name:A187 CN3 (pin 8 & 7) at the underside of the VMCU.

Untwist Green and Yellow wires:Yellow wire = #7004Green wire = #7005 Place Yellow wire in CAN High slotPlace Green wire in CAN Low slotClose CANcliQ.

2nd CANbus

Find the twisted Green and Orange wires in the horizontally placed connector (XC140) in the left top corner of the fuse box.

Untwist green and Orange wiresOrange wire # 7008Green wire # 7009Place Orange wire in CAN High slot.Place Green wire in CAN low slot.Close DatacliQ

Power + Ground

Connections at backside of fuse box.

Ground (KL31)Ground strip at the right side (Black arrow)

Continuous Power (KL30)Lowest for connection points at white Whitefuse box part (Red arrow).

Power on Ignition (KL15)Upper 2 connection points at white fuse box part. (Yellow arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014

© Squarell 2014

© Squarell 2014

Version 16102014 ENGCopyright © Squarell 2014

BKYERDGR

YE

© Squarell 2014

CQ

ID 180CAN

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Vo

lvo

FH

(4

)Eu

ro 6

20

12

+

Page 76: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen 2 locks, remove dashboard capRemove lower dashboard panel

Find the VECU on right side of fuse box. (orange arrow)

CANbus

Untwist Green and Orange wires, Place Orange wire in CAN High slotPlace Green wire in CAN Low slotClose CANcliQ.

J1708 bus Untwist Brown and Orange wires, Place Brown wire in High slotPlace Orange wire in Low slotClose DatacliQ.

Power + Ground

Connections on the Brown Body Builder PB1 connector (Purple arrow)

Ground (KL31):Pin 1, or Pin 21 (black arrow)

Continuous Power (KL30):Pin 30 (Red arrow)

Power on Ignition (KL15):Pin 2 (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, Engine Coolant Temperature and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation. The Engine Coolant Temperature and the Fuel Level can only be supported with a 6628-31 J1708 Diode or FLX12 Flex .

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

BR

RDBK

YEOR

GNOR

CAN LOW

CAN HIGH

© Squarell 2011

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

© Squarell 2011

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Vo

lvo

FL

(1st

gen

Fac

elif

t) 2

00

0-2

00

5

Page 77: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At passenger sideOpen 2 locks, remove dashboard capRemove lower dashboard panel

Find the VECU on right side of fuse box. (orange arrow)

CANbus

Untwist Green and Orange wires, Place Orange wire in CAN High slotPlace Green wire in CAN Low slotClose CANcliQ.

J1708 bus Untwist Brown and Orange wires, Place Brown wire in High slotPlace Orange wire in Low slotClose DatacliQ.

Power + Ground

Connections on the Brown Body Builder PB1 connector (Purple arrow)

Ground (KL31):Pin 1, or Pin 21 (black arrow)

Continuous Power (KL30):Pin 30 (Red arrow)

Power on Ignition (KL15):Pin 2 (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 48V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, Engine Coolant Temperature and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation. The Engine Coolant Temperature and the Fuel Level can only be supported with a 6628-31 J1708 Diode or FLX12 Flex .

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

BR

RDBK

YEOR

GNOR

CAN LOW

CAN HIGH

© Squarell 2011

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

© Squarell 2011

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Vo

lvo

FL

(2n

dge

n)

20

06

-20

12

Page 78: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At the passenger side open up the cover with 2 plastic clips.

In the fuse box at the right side, you will find the Volvo CAN controller.

CANbus

Untwist the Yellow and Green wire from the 4 pin connector between the green and blue connector.

Place the Yellow wire in the CAN High slot.Place the Green wire in the CAN low slot.Close the CANcliQ properly.

Power + Ground

Ground (KL31) :White wire (White arrow).

Continuous Power (KL30) :Red wire(Red arrow).

Power on Ignition (KL15) :Black wire (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014© Squarell 2014

WH

YL

GN

RD

© Squarell 2014

CQVersion 16102014 ENGCopyright © Squarell 2014

BK

Vo

lvo

FL

(2n

dge

n F

ace

lift)

Eu

ro 6

20

13

+

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Page 79: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Remove screws at extractable cup holderOpen triangular shaped upper dashboard panel

Remove 4 screws of fuse boxOpen fuse box compartmentFind the VECU under the fuse box

CANbus

Untwist Green and Yellow wires, Place Yellow wire in CAN High slotPlace Green wire in CAN Low slotClose CANcliQ.

J1708 bus (DatacliQ)Untwist Grey and Orange wires, Place Orange wire in High slotPlace Grey wire in low slotClose DatacliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31)Green connector with white wires (White arrow)

Continuous Power (KL30)Free terminals “from 50 to 54” (Red arrow).

Power on Ignition (KL15)Free terminals “from 55 to 62” (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, Engine Coolant Temperature and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation. The Engine Coolant Temperature and the Fuel Level can only be supported with a 6628-31 J1708 Diode or FLX12 Flex .

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

© Squarell 2011

RDBKWHOG GY GR YE

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Vo

lvo

FM

(1

stge

n)

19

98

-20

02

Page 80: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Remove screws at extractable cup holderOpen triangular shaped upper dashboard panel

Remove 4 screws of fuse boxOpen fuse box compartmentFind the VECU under the fuse box

CANbus

Untwist Green and Yellow wires, Place Yellow wire in CAN High slotPlace Green wire in CAN Low slotClose CANcliQ.

J1708 bus (DatacliQ)Untwist Grey and Orange wires, Place Orange wire in High slotPlace Grey wire in low slotClose DatacliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31)Green connector with white wires (White arrow)

Continuous Power (KL30)Free terminals “from 50 to 54” (Red arrow).

Power on Ignition (KL15)Free terminals “from 55 to 62” (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, Engine Coolant Temperature and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation. The Engine Coolant Temperature and the Fuel Level can only be supported with a 6628-31 J1708 Diode or FLX12 Flex .

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

© Squarell 2011

RDBKWHOG GY GR YE

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Vo

lvo

FM

(2

nd

gen

) 2

00

2-2

01

2

Page 81: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Open up the dashboard by removing the top cover and the side cover at the passenger side to get access to the VMCU(Vehicle Master Control Unit).

Main CANbus

Find the twisted Green and Yellow wires in the blue connector code name:A187 CN3 (pin 8 & 7) at the underside of the VMCU.

Untwist Green and Yellow wires:Yellow wire = #7004Green wire = #7005 Place Yellow wire in CAN High slotPlace Green wire in CAN Low slotClose CANcliQ.

2nd CANbus

Find the twisted Green and Orange wires in the horizontally placed connector (XC140) in the left top corner of the fuse box.

Untwist green and Orange wiresOrange wire # 7008Green wire # 7009Place Orange wire in CAN High slot.Place Green wire in CAN low slot.Close DatacliQ

Power + Ground

Connections at backside of fuse box.

Ground (KL31)Ground strip at the right side (Black arrow)

Continuous Power (KL30)Lowest for connection points at white Whitefuse box part (Red arrow).

Power on Ignition (KL15)Upper 2 connection points at white fuse box part. (Yellow arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014

© Squarell 2014

© Squarell 2014

Version 16102014 ENGCopyright © Squarell 2014

BKYERDGR

YE

© Squarell 2014

CQ

ID 180CAN

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Vo

lvo

FM

(2

nd

gen

Fac

elif

t) E

uro

6 2

01

3+

Page 82: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Remove screws at extractable cup holderOpen triangular shaped upper dashboard panel

Remove 4 screws of fuse boxOpen fuse box compartmentFind the VECU under the fuse box

CANbus

Untwist Green and Yellow wires, Place Yellow wire in CAN High slotPlace Green wire in CAN Low slotClose CANcliQ.

J1708 bus (DatacliQ)Untwist Grey and Orange wires, Place Orange wire in High slotPlace Grey wire in low slotClose DatacliQ.

Power + Ground

Connections at backside of fuse box.

Ground (KL31)Green connector with white wires (White arrow)

Continuous Power (KL30)Free terminals “from 50 to 54” (Red arrow).

Power on Ignition (KL15)Free terminals “from 55 to 62” (Black arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires. This vehicle type is not supporting the Total Fuel Used, Engine Coolant Temperature and the Fuel Level on the Direct CANbus. Squarell unit will start counting the Total Fuel Used since the installation. The Engine Coolant Temperature and the Fuel Level can only be supported with a 6628-31 J1708 Diode or FLX12 Flex .

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2011

© Squarell 2011

© Squarell 2011

RDBKWHOG GY GR YE

© Squarell 2011

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

CQ

ID 280J1708

Version 24102013 ENGCopyright © Squarell 2013

Vo

lvo

FM

X (

1st

gen

) 2

01

0-2

01

2

Page 83: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Open up the dashboard by removing the top cover and the side cover at the passenger side to get access to the VMCU(Vehicle Master Control Unit).

Main CANbus

Find the twisted Green and Yellow wires in the blue connector code name:A187 CN3 (pin 8 & 7) at the underside of the VMCU.

Untwist Green and Yellow wires:Yellow wire = #7004Green wire = #7005 Place Yellow wire in CAN High slotPlace Green wire in CAN Low slotClose CANcliQ.

2nd CANbus

Find the twisted Green and Orange wires in the horizontally placed connector (XC140) in the left top corner of the fuse box.

Untwist green and Orange wiresOrange wire # 7008Green wire # 7009Place Orange wire in CAN High slot.Place Green wire in CAN low slot.Close DatacliQ

Power + Ground

Connections at backside of fuse box.

Ground (KL31)Ground strip at the right side (Black arrow)

Continuous Power (KL30)Lowest for connection points at white Whitefuse box part (Red arrow).

Power on Ignition (KL15)Upper 2 connection points at white fuse box part. (Yellow arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2014

© Squarell 2014

© Squarell 2014

Version 16102014 ENGCopyright © Squarell 2014

BKYERDGR

YE

© Squarell 2014

CQ

ID 180CAN

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

Vo

lvo

FM

X (

1st

gen

Fac

elif

t) E

uro

6 2

01

3+

Page 84: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At Passenger side, remove the pockets from the dashboard.

Take the OBD connector out of the socket.There will be 2 pairs of Orange Black and Orange Brown wires.

CANbus

Untwist Orange/Black and Orange/Brown wires, pin 3 & 11!

Place Orange/Black wire in CAN HighPlace Orange/Brown wire in CAN LowClose CANcliQ.

Power + Ground

Connections at the same wiring loom as the CANbus lines.

Ground (KL31) :Brown wire see the picture (Brown arrow)

Continuous Power (KL30) :Red/Black wire see the picture (Red/Black arrow)

Power on Ignition (KL15) :Black/Red wire see the picture (Black/red arrow)

Warning! CANcliQ closes only once. Please connect Squarell devices to a 10V to 34V power supply. Please use certified crimping tools to connect the wires.

CAN LOW

CAN HIGH

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2015

© Squarell 2015

Version 23022015 ENGCopyright © Squarell 2015

RD/BK

BK/RD

OR/BK

© Squarell 2015

OR/BR BR

© Squarell 2015

CQ

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

VW

Co

nst

ella

tio

n 2

01

0+

Page 85: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

At Passenger side Remove glove compartment with 3 black Clips (orange arrow)

Find the twisted Yellow and Green CANbus wires behind the HD9 OBD connector (Orange arrow)

CANbus

Untwist Green and Yellow wires,Place Yellow (Pin C) wire in CAN HighPlace Green on (Pin D) wire in CAN LowClose CANcliQ.

Power + Ground

Connections at backside of the OBD connector.

Ground (KL31) :Pin A Brown wires (Black arrow)

Continuous Power (KL30) :Pin B Red-Blue wires (Red arrow)

Power on Ignition (KL15) :Yellow wires (Yellow arrow)

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2012

Version 04062012 ENGCopyright © Squarell 2012

YE

GN

© Squarell 2012

© Squarell 2012

BRCAN LOW

CAN HIGH

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

RD/BL

YE

CQ

VW

Wo

rke

r 2

00

3+

Page 86: Table of Content| Installation Instructions | Heavy Commercial … · Change of connections when making use of Navcan device About This additional page is for the use with Navman

Location

Find the Deutsch OBD connector department and release this with the 4 Screws.

CANbus

At the Backside of the Deutsch connector you find all required wires for this installation.

Untwist Yellow & Green wires.

Place Yellow wire in CAN High slot.Place Green wire in CAN Low slot.

Close CANcliQ.

J1708

Untwist Blue & Yellow wires.

Place Blue wire in High slot.Place Yellow wire in Low slot.

Close DatacliQ (ID280).

Power + Ground

Ground (KL31)Deutsch connector Position A(Black Arrow)

Continuous Power (KL30)Deutsch connector pin B(Red arrow)

Power on Ignition (KL15)Deutsch connector pin J(Red/Orange Arrow).

Warning! CANcliQ or DatacliQ closes only once. Please repower the Squarell Device after the installation is completed. Please connect Squarell devices to a 10V to 30V power supply. Please use certified crimping tools to connect the wires.

ZY

XW

VU

TS

RQ

PO

NM

LK

JI

HG

FE

DC

BA

© Squarell 2015© Squarell 2015

Version 26112015 ENGCopyright © Squarell 2015

YL

BL

© Squarell 2015

CQ

ID 280CANbus

CAN LOW

CAN HIGH

CAN LOW

CAN HIGH

OB

D

CA

Ncl

iQ

DA

TAcl

iQ1

DA

TAcl

iQ2

DA

TAcl

iQ3

DA

TAcl

iQ4

DA

TAcl

iQ5

DA

TAcl

iQ6

Veh

icle

sp

ec.

CA

N1

-L

CA

N1

-H

CA

N2

-L

CA

N2

-H

CA

N3

-L

CA

N3

-H

CA

N4

-L

CA

N4

-H

K-L

ine1

K/L

-Lin

e1

K-L

ine2

K/L

-Lin

e2

J17

08

-1

J17

08

+ 1

J17

08

-2

J17

08

+ 2

Au

x 1

Au

x 2

Au

x 3

Au

x 4

GN

D B

lack

Po

wer

ig

nit

ion

Po

wer

co

nti

nu

YL

GN

We

ste

rn S

tar

48

00