TA Instruments

TA Instruments · New Castle, DE USA Lindon, UT USA Crawley, United Kingdom Shanghai, China Beijing, China Taipei, Taiwan Tokyo, Japan Seoul, Korea Bangalore, India Paris, France

Embed Size (px)

Citation preview

Page 1: TA Instruments · New Castle, DE USA Lindon, UT USA Crawley, United Kingdom Shanghai, China Beijing, China Taipei, Taiwan Tokyo, Japan Seoul, Korea Bangalore, India Paris, France

TA Instruments

Thermal cover:Layout 1 1/18/11 3:56 PM Page 2

Page 2: TA Instruments · New Castle, DE USA Lindon, UT USA Crawley, United Kingdom Shanghai, China Beijing, China Taipei, Taiwan Tokyo, Japan Seoul, Korea Bangalore, India Paris, France

New Castle, DE USA

Lindon, UT USA

Crawley, United Kingdom

Shanghai, China

Beijing, China

Taipei, Taiwan

Tokyo, Japan

Seoul, Korea

Bangalore, India

Paris, France

Eschborn, Germany

Brussels, Belgium

Etten-Leur, Netherlands

Sollentuna, Sweden

Milano, Italy

Barcelona, Spain

Melbourne, Australia

Mexico City, Mexico

Thermal cover:Layout 1 1/18/11 3:56 PM Page 3

Page 3: TA Instruments · New Castle, DE USA Lindon, UT USA Crawley, United Kingdom Shanghai, China Beijing, China Taipei, Taiwan Tokyo, Japan Seoul, Korea Bangalore, India Paris, France

SIMULTANEOUS TGA/DSC

Providing high-quality, true differential simultaneous measurements

Thermal Brochure 2011:Layout 1 1/18/11 3:34 PM Page 62

Page 4: TA Instruments · New Castle, DE USA Lindon, UT USA Crawley, United Kingdom Shanghai, China Beijing, China Taipei, Taiwan Tokyo, Japan Seoul, Korea Bangalore, India Paris, France

System Design Horizontal Balance & FurnaceBalance Design Dual Beam (growth compensated)Sample Capacity 200 mg (350 mg including sample holder)Balance Sensitivity 0.1 μgFurnace Type Bifilar WoundTemperature Range Ambient to 1500 ˚CHeating Rate – Ambient to 1000 ˚C 0.1 to 100 ˚C/minHeating Rate – Ambient to 1500 ˚C 0.1 to 25 ˚C/minFurnace Cooling Forced Air (1500 to 50 ˚C in < 30 min,

1000 ˚C in 50 ˚C in < 20 min)Thermocouples Platinum/Platinum-Rhodium (Type R)Temperature Calibration Curie Point or Metal Standards (1 to 5 Points)DTA Sensitivity 0.001 ˚CCalorimetric Accuracy/Precision ± 2% (based on metal standards)Mass Flow Controller with Automatic Gas Switching IncludedVacuum to 7 Pa (0.05 torr)Reactive Gas Capability Included – separate gas tubeDual Sample TGA IncludedAuto-Stepwise TGA IncludedSample Pans Platinum: 40 μL, 110 μL

Alumina: 40 μL, 90 μL

The Q600 provides simultaneous measurement ofweight change (TGA) and true differential heatflow (DSC) on the same sample from ambientto 1,500 ˚C. It features a field-proven horizontaldual beam design with automatic beam growthcompensation, and the ability to analyze two TGAsamples simultaneously. DSC heat flow data isdynamically normalized using the instantaneoussample weight at any given temperature.

6564

SDT Q600 SPECIFICATIONS

Thermal Brochure 2011:Layout 1 1/18/11 3:34 PM Page 64

Page 5: TA Instruments · New Castle, DE USA Lindon, UT USA Crawley, United Kingdom Shanghai, China Beijing, China Taipei, Taiwan Tokyo, Japan Seoul, Korea Bangalore, India Paris, France

SDT TECHNOLOGY High Resolution SDTIf separation of closely related weight losses is required, theQ600 offers an automated version of StepWise Isothermal(SWI), the classical technique for improved TGA resolution. The stepwise isothermal approach consists of heating at a constant rate until a weight change begins (as determined byan operator-chosen rate or amount of weight loss) and thenholding isothermally until the weight change is complete. Thissequence of heating and isothermal steps is repeated for eachweight change encountered. The result is optimum weight lossresolution.

Temperature Calibration and Weight Loss VerificationTA Instruments offers the widest range of ICTAC certified andNIST traceable Curie Point reference materials that provide SDTapparatus temperature calibration over the range from 150 to1,120 ˚C. TA Instruments also offers certified Mass Loss Refer-ence Materials for validation of SDT instrument performance.

Q600 Sample PansPlatinum pans (40 and 110 μL) and ceramic cups (40 and 90 μL) are available for use with the Q600. The platinum cupsare recommended for operation to 1000 ˚C, and for their general inertness and ease of cleaning. The ceramic cups areadvised for operation to 1,500 ˚C, and for samples that reactwith platinum.

6766

Thermobalance The Q600 features a highly reliable horizontal dual-balance mechanism that supports preciseTGA and DSC measurements. It delivers superiority in weight signal measurements (sensitivity, accuracy and precision) over what is available from single beam devices, since the dual beam design virtually eliminates beam growth and buoyancy contributions to the underlying signal. It also uniquely permits independent TGA measurements on two samples simultaneously.

Temperature Control and Measurement A matched Platinum / Platinum-Rhodium thermocouple pair within the ceramic beams provides direct sample, reference, and differential temperature measurements from ambient to 1,500 ºC. This results in the best available sensitivity in detection of thermal events. Curie Point or pure metalstandards can be used for single or multi-point temperature calibration. Calibration of the DSC signal with sapphire standards results in a differential heat flow (DSC) signal that is intrinsically superior to that from single beam devices.

Furnace The Q600 features a rugged, reliable, horizontal furnace encased in a perforated stainless steelenclosure. The design ensures accurate and precise delivery of programmed and isothermal operation over the full temperature range from ambient to 1,500 ºC. The design also provides foroperator ease-of-use due to its automatic furnace opening / closing, easy sample loading, andrapid post-experiment furnace cool-down.

Purge Gas System A horizontal purge gas system with digital mass flow control and integral gas switching capabilityprovides for precise metering of purge gas to the sample and reference pans. The design producesbetter baselines, prevents back diffusion, and efficiently removes decomposition products from thesample area. A separate Inconel® gas inlet tube efficiently delivers reactive gas to the sample. TheQ600 exhaust gas port can be readily connected to a MS or FTIR for component identification purposes.

® Inconel is a registered trademark of Special Metals Corporation

Sample Cup

Thermocouple

Sample Holder

Balance Arm

Sample/Reference Cups

Reactive Gas Inlet

Dual-Balance Mechanism

Furnace

Photodiodes and Sensors

Balance/Thermocouple Beams

Horizontal Purge Gas flow

Thermal Brochure 2011:Layout 1 1/18/11 3:34 PM Page 66

Page 6: TA Instruments · New Castle, DE USA Lindon, UT USA Crawley, United Kingdom Shanghai, China Beijing, China Taipei, Taiwan Tokyo, Japan Seoul, Korea Bangalore, India Paris, France

6968

APPLICATIONS

High Sensitivity This figure shows a high sensitivity application of the Q600in which a small (3 mg) sample of sodium tungstate is analyzed at 10 ˚C/min from ambient to 800 ˚C. The TGAand derivative TGA (DTG) signals quantitatively record thedehydration step. The DSC trace quantitatively shows the lossof water plus higher temperature solid state phase and melting transitions respectively. The latter pair are thermalevents where no weight loss occurs.

Simultaneous DSC/TGA

This figure contains simultaneous DSC and TGA data to1,300 ˚C for a soda ash sample. The TGA signal measuresthe dehydration and the onset of a higher temperature decomposition. The DSC signal reveals transitions associatedwith the dehydration, a polymorphic phase transition and the high temperature melt. The inset shows details about thephase transition. In the Q600, heat flow integrations are automatically normalized using the dynamic weight at thestart of each transition.

Improved DSC DataIn SDT experiments, superior accuracy in DSC data is obtained when the instantaneous weight (rather than the initial sample weight) is used in heat flow calculations. Thisfigure shows data for sodium chloride (which loses weight on heating) cycled through its melt four times, and the heat offusion (J/g) determined using the instantaneous weight. Theaccompanying table shows a comparison of this data versusan identical experiment where the initial sample weight was used for calculating the DSC data in each cycle. The differences in reproducibility are significant.

Cycle 1 Cycle 2 Cycle 3 Cycle 4

Heat of Fusion 468.7 384.1 324.7 266.9

Initial Weight (J/g)

Heat of Fusion 468.7 459.1 459.2 464.4

Instantaneous Weight (J/g)

70

80

100

90

-8

-6

-4

-2

0 400200 600 800 1000 1200 1400Temperature (˚C)

Dehydration

300

Polymorphic Phase Transitions

MeltingTransition

Wei

ght (

%)

Hea

t Flo

w (W

/g)

400 500 600

-12

-8

-10

0

-2

-4

-6

8

6

4

16

14

12

10

20 40 60

13.27mg

468.7J/g 459.1J/g 459.2J/gHeat of Fusion using Weight at Start of Integration

Heat of Fusion using Original Weight (13.26mg)

464.4J/g

468.7J/g 384.1J/g 324.7J/g 266.9J/g

9.379mg

11.27mg

7.628mg

80 100Time (min)

Hea

t Flo

w (W

/g)

Wei

ght (

mg)

2

60

66

72

78

84

96

907

4

1

-2

0.9

-0.6

-0.3

0.0

0.6

0.3

0 200 400 600 800Temperature (˚C)

Solid State and Melting Transitions

Dehydration

Wei

ght (

%)

Heat Flow (W/g)

Der

iv. W

eigh

t (%

/˚C)

102

Thermal Brochure 2011:Layout 1 1/18/11 3:34 PM Page 68

Page 7: TA Instruments · New Castle, DE USA Lindon, UT USA Crawley, United Kingdom Shanghai, China Beijing, China Taipei, Taiwan Tokyo, Japan Seoul, Korea Bangalore, India Paris, France

© 2010 TA Instruments. All rights reserved. L90010.001

tainstruments.com

Thermal cover:Layout 1 1/18/11 3:56 PM Page 1