All works to be in accordance with the Building Code of statutory regulations and local authority requirements. Contractor to ensure consistency between similar materials is maintained. Contractor to notify GC of any discrepancies,dimensional inconsistencies or the need for clarification prior to manufacture. GC design to approve all contractors detailed drawings/setting out prior to construction. Contractor to confirm stability and feasibility of all units/components prior to manufacture. Contractor to liaise with Electrical contractors to ensure all power,data,communication requirements are accessible. All drawings to be verified on site - do not scale. All dimensions need to be checked on site. CLIENT: PROJECT: NOTES: GC Studio Pty Ltd 2/19 Reserve Street, Beaconsfield, NSW 2015 T:02 9698 3204 E: [email protected] ISSUE REVISION DETAILS INITIALS DATE A RENOVATION PROPOSAL CC 28/06/2019 WILLAWARRIN FARM 95-115 ARMIDALE ROAD, WILLAWARRIN, NSW 2440 . . . . . . . . SCALE BAR: North Point: DRAWN BY: REVISION: CHECKED BY: BWT SCALE: @ A2 B DRAWING TITLE: DRAWING STATUS: DRAWING NUMBER: FOR INFORMATION PROJECT NUMBER: 1902 ISSUE REVISION DETAILS INITIALS DATE B RENOVATION PROPOSAL CC 17/10/2019 002 LOCATION PLAN CC CURRENT SITUATION N/A SITE LOCATION: ADDRESS: 95-115 ARMIDALE ROAD, WILLAWARRIN, NSW 2440

T6-20-77 - Architectural plans...GREENHOUSE TYPE 1 TYPICAL FLOOR PLAN 2-SCALE: 1:250 GREENHOUSE TYPE 2 TYPICAL FLOOR PLAN 3-SCALE: 1:50 GREENHOUSE TYPICAL LAYOUT PLAN 15000 6300 2400

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: T6-20-77 - Architectural plans...GREENHOUSE TYPE 1 TYPICAL FLOOR PLAN 2-SCALE: 1:250 GREENHOUSE TYPE 2 TYPICAL FLOOR PLAN 3-SCALE: 1:50 GREENHOUSE TYPICAL LAYOUT PLAN 15000 6300 2400

All works to be in accordance with the Building Code of statutory regulations and local authority requirements.

Contractor to ensure consistency between similar materials is maintained.

Contractor to notify GC of any discrepancies,dimensional inconsistencies or the need for clarification prior to manufacture.

GC design to approve all contractors detailed drawings/setting out prior to construction.

Contractor to confirm stability and feasibility of all units/components prior to manufacture.

Contractor to liaise with Electrical contractors to ensure all power,data,communication requirements are accessible.

All drawings to be verified on site - do not scale.

All dimensions need to be checked on site.

CLIENT:

PROJECT:

NOTES:

GC Studio Pty Ltd

2/19 Reserve Street, Beaconsfield, NSW 2015

T:02 9698 3204 E: [email protected]

ISSUE REVISION DETAILS INITIALS DATE

A RENOVATION PROPOSAL CC 28/06/2019

WILLAWARRIN FARM

95-115 ARMIDALE ROAD,

WILLAWARRIN, NSW 2440

.

.

.

.

.

.

.

.

SCALE BAR:

North Point:

DRAWN BY:

REVISION:

CHECKED BY:

BWT

SCALE: @ A2

B

DRAWING TITLE:

DRAWING STATUS: DRAWING NUMBER:

FOR INFORMATION

PROJECT NUMBER:

1902

ISSUE REVISION DETAILS INITIALS DATE

B RENOVATION PROPOSAL CC 17/10/2019

002

LOCATION PLAN

CC

CURRENT SITUATION

N/A

SITE LOCATION:

ADDRESS: 95-115 ARMIDALE ROAD, WILLAWARRIN, NSW 2440

Page 2: T6-20-77 - Architectural plans...GREENHOUSE TYPE 1 TYPICAL FLOOR PLAN 2-SCALE: 1:250 GREENHOUSE TYPE 2 TYPICAL FLOOR PLAN 3-SCALE: 1:50 GREENHOUSE TYPICAL LAYOUT PLAN 15000 6300 2400

All works to be in accordance with the Building Code of statutory regulations and local authority requirements.

Contractor to ensure consistency between similar materials is maintained.

Contractor to notify GC of any discrepancies,dimensional inconsistencies or the need for clarification prior to manufacture.

GC design to approve all contractors detailed drawings/setting out prior to construction.

Contractor to confirm stability and feasibility of all units/components prior to manufacture.

Contractor to liaise with Electrical contractors to ensure all power,data,communication requirements are accessible.

All drawings to be verified on site - do not scale.

All dimensions need to be checked on site.

CLIENT:

PROJECT:

NOTES:

GC Studio Pty Ltd

2/19 Reserve Street, Beaconsfield, NSW 2015

T:02 9698 3204 E: [email protected]

ISSUE REVISION DETAILS INITIALS DATE

A RENOVATION PROPOSAL CC 28/06/2019

WILLAWARRIN FARM

95-115 ARMIDALE ROAD,

WILLAWARRIN, NSW 2440

.

.

.

.

.

.

.

.

SCALE BAR:

North Point:

DRAWN BY:

REVISION:

CHECKED BY:

BWT

SCALE: @ A2

B

DRAWING TITLE:

DRAWING STATUS: DRAWING NUMBER:

FOR INFORMATION

PROJECT NUMBER:

1902

ISSUE REVISION DETAILS INITIALS DATE

B RENOVATION PROPOSAL CC 17/10/2019

DULUX

JUST-RITE

WHITE PAINT

DULUX NATURE WHITE

CODE: 15W

INTERIOR WALL & CEILING

POLYCARBONATE

ROOF FIXED WINDOW

CLEAR LASERLITE 2000 POLYCARBONATE ROOF

SHEET

COLORBOND

COLORBOND

DEEP OCEAN

EXTERIOR WALL & ROOF

FLOOR TILE

BEAUMONT TILEINTERIOR FLOOR

Ales Dark Grey Colour Bodied-Porcelain1007743_600X600

PALE EUCALYPT COLOUR

WINDOWSMOKE CONTROL

ACCOMMODATION HOUSE WINDOW

& DOOR

MATT BLACK ALUMINUM FRAME DOUBLE GLAZING

WINDOW VISIONEERING E60 GLAZED FIRE DOORS FIRE RATE: -/60/-

003

N/A

MATERIAL SCHEDULE

CC

CODE ITEM DESCRIPTION / FINISH LOCATION SUPPLIER

PT

01

ML

01

ML

02

GL

01

TL

01

AL

01

PT

01

ML

01

ML

02

GL

01

TL

01

AL

01

ROLLER SHUTTER DOORROLLER SHUTTER/ DOOR

COLORBOND

FL

01

FLOOR FINISHCONTRACTOR

INTERIOR FLOOR FINISH

POLISHED CONCRETE WITH CLEAR FINISH

FL

01

C

C MATERIAL SUPPLIER UPDATE CC 24/01/2020

Page 3: T6-20-77 - Architectural plans...GREENHOUSE TYPE 1 TYPICAL FLOOR PLAN 2-SCALE: 1:250 GREENHOUSE TYPE 2 TYPICAL FLOOR PLAN 3-SCALE: 1:50 GREENHOUSE TYPICAL LAYOUT PLAN 15000 6300 2400

G

I

P

G

I

P

G

I

P

G

P

G

P

CABLE MARKER - 47.998

TPIT6 - 51.210

INVP450 - 51.106

PS100 - 42.768

PS101 - 43.297

PS102 - 42.925

PS01 - 52.137

PS04 - 50.989

PS03 - 49.976

PS103 - 42.774

PS05 - 48.675

TR500 - 43.227

TR800 - 43.433

TR800 - 43.138

43.574

43.367

TR300

TR300

TR500

TR2000 - 44.418 (Dead Tree)

TR700 - 42.831

TR1000 - 42.891

TR1600 - 43.069

TR400 - 44.719

TR600 - 44.558

TR600 - 48.158

TR300 - 48.802

TR1200 - 49.020

CABLE MARKER - 49.635

TR1000 - 47.926

TR500 - 47.182

HELM1062 - 48.854

TR700 - 47.763

TR500 - 46.840

TR700 - 50.209

TR600 - 48.768

TR800 - 49.469

TR800 - 49.349

TR500 - 49.359

TR500 - 49.264

TR800 - 47.904

TR800 - 48.530

TR800 - 48.997

TR500 - 48.569

TR800 - 48.884

TR500 - 48.924

TR800 - 49.307

TR500 - 48.611

TR600 - 48.906

45.370

45.669

46.025

46.207

45.841

44.355

44.413

44.459

45.068

45.428

TR400 - 44.781

LOT 3

(DP 258968)

LOT 4

(DP 258968)

LOT 2

(DP 258968)

LOT 12

(DP 813713)

LOT 11

(DP 813713)

LOT 2

(DP 800846)

TOP DOOR - 54.619

52.00

5

1

.5

0

51.0

0

5

0

.

5

0

53.00

5

2

.5

0

50.00

4

9

.5

0

4

9

.

0

0

5

0

.

0

0

4

9

.5

0

4

9

.

0

0

4

8

.0

0

4

9

.

5

0

4

4

.5

0

4

5

.0

0

46.00

4

4

.

0

0

4

3

.

5

0

4

8

.

5

0

4

7

.5

0

4

7

.0

0

4

6

.

5

0

4

6

.

0

0

4

5

.

5

0

5

1

.0

0

50.50

49.00

4

8

.5

0

4

8

.0

0

4

7

.

5

0

4

7

.

0

0

4

6

.

5

0

4

9

.

5

0

4

9

.

0

0

4

8

.

0

0

4

2

.

0

0

4

2

.

5

0

4

4

.

5

0

4

3

.

0

0

4

3

.

5

0

44.0

0

43.0

0

4

3

.

0

0

4

3

.

5

0

4

2

.5

0

4

2

.

5

0

42.50

42.50

42.0

0

4

2

.0

0

42.00

4

2

.0

0

4

1

.

5

0

4

1

.

5

0

4

1

.

5

0

4

1

.

0

0

4

1

.

0

0

41.00

4

0

.

5

0

3

9

.

5

0

3

9

.

0

0

4

0

.

0

0

4

0

.

0

0

4

5

.

0

0

4

5

.

5

0

4

4

.5

0

4

3

.

0

0

4

3

.

0

0

4

3

.

5

0

4

3

.5

0

4

2

.

5

0

42.5

0

4

2

.

0

0

4

3

.

0

0

4

2

.

5

0

4

3

.

0

0

40.00

3

9

.

5

0

4

0

.

5

0

4

1

.

0

0

4

2

.5

0

43.00

4

2

.

0

0

4

9

.

5

0

4

9

.

0

0

4

8

.

5

0

4

8

.0

0

4

7

.5

0

4

7

.0

0

4

6

.5

0

4

6

.

0

0

4

6

.

0

0

4

6

.0

0

45.5

0

4

5

.

5

0

4

5

.5

0

4

4

.

5

0

44.50

4

4

.5

0

44.00

4

4

.0

0

43.50

43.50

4

3

.

5

0

43.50

4

3

.5

0

43.00

43.00

4

3

.

0

0

4

3

.

0

0

4

3

.

0

0

43.00

4

2

.

5

0

4

2

.

5

0

42.50

4

2

.

5

0

42.00

4

2

.

0

0

4

2

.

0

0

4

2

.

0

0

4

2

.0

0

4

1

.

5

0

4

1

.

5

0

4

1

.5

0

4

1

.

5

0

4

1

.

5

0

4

1

.

5

0

4

1

.0

0

41.00

4

1

.

0

0

4

1

.

0

0

40.50

40.50

4

0

.

5

0

3

9

.

5

0

39.50

3

9

.

5

0

3

9

.

0

0

39.0

0

39.00

3

9

.0

0

3

8

.

5

0

38.00

3

8

.0

0

3

7

.0

0

3

7

.

0

0

5

0

.0

0

4

5

.

0

0

45.00

4

5

.0

0

4

0

.

0

0

4

0

.

0

0

4

0

.

0

0

4

0

.0

0

40.00

5

1

.

0

0

5

0

.5

0

5

2

.0

0

5

2

.0

0

5

1

.

5

0

51.50

5

3

.

0

0

5

2

.

5

0

5

2

.

0

0

5

1

.

5

0

4

8

.

5

0

4

7

.

5

0

4

7

.

0

0

4

6

.

5

0

4

6

.

0

0

4

5

.

5

04

4

.

5

0

4

5

.

0

0

C

O

P

S

E

O

F

T

R

E

E

S

C

O

P

S

E

O

F

T

R

E

E

S

C

O

P

S

E

O

F

T

R

E

E

S

1

2

3

4

5

S

T

N

S

T

N

S

T

N

PS02 - 52.282

S

T

N

S

T

N

S

T

N

S

T

N

S

T

N

S

T

N

S

T

N

A

R

M

ID

A

L

E

R

O

A

D

T

R

E

N

C

H

D

R

A

I

N

INVP450 - 49.993

TR400

TR400

TR700

TR800

TR600

H

IC

K

E

Y

S

C

R

E

E

K

DRIVEWAY ACCESS

1

2

4

5

6

7

9

10

11

12

13

14

15

16

3

8

10000

10000

1

0

0

0

0

0

4

0

0

2

0

40000

1

0

0

0

0

1

2

0

1

5

0

P P PPPP

1

0

0

0

0

1

0

0

0

0

P

P

P

TRUCKLOADINGBAY3500X8800

All works to be in accordance with the Building Code of statutory regulations and local authority requirements.

Contractor to ensure consistency between similar materials is maintained.

Contractor to notify GC of any discrepancies,dimensional inconsistencies or the need for clarification prior to manufacture.

GC design to approve all contractors detailed drawings/setting out prior to construction.

Contractor to confirm stability and feasibility of all units/components prior to manufacture.

Contractor to liaise with Electrical contractors to ensure all power,data,communication requirements are accessible.

All drawings to be verified on site - do not scale.

All dimensions need to be checked on site.

CLIENT:

PROJECT:

NOTES:

GC Studio Pty Ltd

2/19 Reserve Street, Beaconsfield, NSW 2015

T:02 9698 3204 E: [email protected]

ISSUE REVISION DETAILS INITIALS DATE

A RENOVATION PROPOSAL CC 28/06/2019

WILLAWARRIN FARM

95-115 ARMIDALE ROAD,

WILLAWARRIN, NSW 2440

.

.

.

.

.

.

.

.

SCALE BAR:

North Point:

DRAWN BY:

REVISION:

CHECKED BY:

BWT

SCALE: @ A2

B

DRAWING TITLE:

DRAWING STATUS: DRAWING NUMBER:

FOR INFORMATION

PROJECT NUMBER:

1902

ISSUE REVISION DETAILS INITIALS DATE

B RENOVATION PROPOSAL CC 17/10/2019

1

-

201

1:2000

CC

SCALE: 1:2000

PROPOSED SITE PLAN

PROPOSED SITE PLAN

20201

A

DE

F

A NEW PROPOSED STAFF ACCOMMODATION HOUSEB NEW PROPOSED PACKING WORK SHOPC NEW PROPOSED FARM STORAGED EXISTING SINGLE STOREY BRICK RESIDENCEE NEW PROPOSED CARPARKF NEW PROPOSED VEGETABLE GREENHOUSE TYPE 1

120m(L) X 15m (W) X 3.4m (H) X10G NEW PROPOSED VEGETABLE GREENHOUSE TYPE 2

60m(L) X 15m (W) X 3.4m (H) X6

F

F

F

FF

FFF

FF

GG

G

LEGEND:

G

B C

C

G

H

K

J

J

K

NEW PROPOSED AGRICULTURAL FERTILIZER STORAGE10m(L) X 10m (W) X 3.8 m (H)NEW PROPOSED 5 INCH WELLS FOR TESTOUTDOOR MARKET GARDEN

H

J

KDEMOLISHING LINE

F

G

GREENHOUSE TYPE 1

OUTDOOR MARKET GARDENK

DEVELOPMENT CALCULATIONS:

OVERALL SITE AREA: 23.17 HECTARES

37490.4 M2

18000M2GREENHOUSE AREA:

GREENHOUSE TYPE 2

OUTDOOR MARKET GARDEN43, 738.8M2

PLANT AREA

5400M2

18.9%

7.77%

193.9M2PROPOSED OVERALL BUILDING:

A NEW PROPOSED STAFFACCOMMODATION HOUSE: 215M2

B NEW PROPOSEDPACKING WORK SHOP: 330M2

C NEW PROPOSED FARMSTORAGE: 550M2

D EXISTING SINGLE STOREYBRICK RESIDENCE:

PROPOSED DRIVE WAY&PARKING: 2121M2

COVERAGEPERCENTAGE

0.56%

0.92%

OVERALL PROPOSED SITECOVERAGE 70, 548.7 M2 30.45%

PERIMETER FIRE FIGHTING ACCESS WITH 4M

GRAVEL ROAD (GATE TO BE INSTALLED AND

ONLY ALLOW TO BE OPENED FOR FIRE

PURPOSE)

D

C BUILDING SET BACK AMENDMENT AND CC 24/01/2020

PERIMETER FIRE FIGHTING ACCESS PROPOSED

D CC 24/01/2020DISABLE TOILET & PARKING ADDED

G

PROPOSED CAR PARK

SWEPT PATH PER

TRAFFIC REPORT

STORM WATER OSD AS PER

STORMWATER MANAGEMENT PLAN L

STORMWATER OSD (AS PER STORMWATERMANAGEMENT PLAN

L

3m(L)x3m(W)x2m(H)STALLM

M

3m(L)x3m(W)x2m(H)STALL

ACCESS GATE PERBUSHFIRE REPORT

0 20M 50M 100M

2.33%

RESIDENTIAL WASTE BINS, PER WASTE MANAGEMENT

MARKET GARDEN WASTE BINS, PER WASTE MANAGEMENT

COMPOSTING FOR GREEN WASTE ON SITE, PER WASTEMANAGEMENT

BIN ROADSIDE COLLECTION POINT, PER WASTEMANAGEMENT

RW

MGW

C

R

PERIMETER FIRE FIGHTING ACCESS WITH 4M

GRAVEL ROAD (PER BUSH-FIRE REPORT)

RW

RW MGW

MGW

C

C

R

AutoCAD SHX Text
HRV
AutoCAD SHX Text
Custom
AutoCAD SHX Text
(c) 2019 Transoft Solutions, Inc. All rights reserved.
AutoCAD SHX Text
HRV
AutoCAD SHX Text
Custom
AutoCAD SHX Text
(c) 2019 Transoft Solutions, Inc. All rights reserved.
Page 4: T6-20-77 - Architectural plans...GREENHOUSE TYPE 1 TYPICAL FLOOR PLAN 2-SCALE: 1:250 GREENHOUSE TYPE 2 TYPICAL FLOOR PLAN 3-SCALE: 1:50 GREENHOUSE TYPICAL LAYOUT PLAN 15000 6300 2400
Page 5: T6-20-77 - Architectural plans...GREENHOUSE TYPE 1 TYPICAL FLOOR PLAN 2-SCALE: 1:250 GREENHOUSE TYPE 2 TYPICAL FLOOR PLAN 3-SCALE: 1:50 GREENHOUSE TYPICAL LAYOUT PLAN 15000 6300 2400

38870

15000

2400

EN

TR

AN

CE

6300

6300

15000

2400

EN

TR

AN

CE

6300

6300

37740 38870

2260

DR.

2260

DR.

58870

2260

DR.

58870

120000

60000

15000

6300

2400

EN

TR

AN

CE

6300

950 27920 950

2260

DR.

27920

All works to be in accordance with the Building Code of statutory regulations and local authority requirements.

Contractor to ensure consistency between similar materials is maintained.

Contractor to notify GC of any discrepancies,dimensional inconsistencies or the need for clarification prior to manufacture.

GC design to approve all contractors detailed drawings/setting out prior to construction.

Contractor to confirm stability and feasibility of all units/components prior to manufacture.

Contractor to liaise with Electrical contractors to ensure all power,data,communication requirements are accessible.

All drawings to be verified on site - do not scale.

All dimensions need to be checked on site.

CLIENT:

PROJECT:

NOTES:

GC Studio Pty Ltd

2/19 Reserve Street, Beaconsfield, NSW 2015

T:02 9698 3204 E: [email protected]

ISSUE REVISION DETAILS INITIALS DATE

A RENOVATION PROPOSAL CC 28/06/2019

WILLAWARRIN FARM

95-115 ARMIDALE ROAD,

WILLAWARRIN, NSW 2440

.

.

.

.

.

.

.

.

SCALE BAR:

North Point:

DRAWN BY:

REVISION:

CHECKED BY:

BWT

SCALE: @ A2

B

DRAWING TITLE:

DRAWING STATUS: DRAWING NUMBER:

FOR INFORMATION

PROJECT NUMBER:

1902

ISSUE REVISION DETAILS INITIALS DATE

B RENOVATION PROPOSAL CC 17/10/2019

1

-

203

VARIOUS

CC

SCALE: 1:250

TYPICAL GREEN HOUSE FLOOR PLAN

GREENHOUSE TYPE 1 TYPICAL FLOOR PLAN

2

-

SCALE: 1:250

GREENHOUSE TYPE 2 TYPICAL FLOOR PLAN

3

-

SCALE: 1:50

GREENHOUSE TYPICAL LAYOUT PLAN

15000

325 1200 250 1200 250 1200 250 1200 250 1200 250 1200 250 1200 250 1200 250 1200 250 1200 325

6300

2400

ENTRANCE 6300

MIR03

MIR03

-0304

04

04

04

03

ONLY FOR INFORMATION

204 -

204

204

204

C

C EGRESS AMENDED CC 29/11/2019

0 10M5M 15M

SCALE 1:250

Page 6: T6-20-77 - Architectural plans...GREENHOUSE TYPE 1 TYPICAL FLOOR PLAN 2-SCALE: 1:250 GREENHOUSE TYPE 2 TYPICAL FLOOR PLAN 3-SCALE: 1:50 GREENHOUSE TYPICAL LAYOUT PLAN 15000 6300 2400

330 1200 250 1200 250 1200 250 1200 250 1200 250 1200 250 1200 250 1200 250 1200 250 1200 380

3400

15000

STEEL STRUCTURE

WITH PVC FILM ROLL COVER

IRRIGATION

SPRINKLER EACH

@6000 METER

SPACE

NATURAL GROUNDFLOOR LEVEL

2200

1200

All works to be in accordance with the Building Code of statutory regulations and local authority requirements.

Contractor to ensure consistency between similar materials is maintained.

Contractor to notify GC of any discrepancies,dimensional inconsistencies or the need for clarification prior to manufacture.

GC design to approve all contractors detailed drawings/setting out prior to construction.

Contractor to confirm stability and feasibility of all units/components prior to manufacture.

Contractor to liaise with Electrical contractors to ensure all power,data,communication requirements are accessible.

All drawings to be verified on site - do not scale.

All dimensions need to be checked on site.

CLIENT:

PROJECT:

NOTES:

GC Studio Pty Ltd

2/19 Reserve Street, Beaconsfield, NSW 2015

T:02 9698 3204 E: [email protected]

ISSUE REVISION DETAILS INITIALS DATE

A RENOVATION PROPOSAL CC 28/06/2019

WILLAWARRIN FARM

95-115 ARMIDALE ROAD,

WILLAWARRIN, NSW 2440

.

.

.

.

.

.

.

.

SCALE BAR:

North Point:

DRAWN BY:

REVISION:

CHECKED BY:

BWT

SCALE: @ A2

B

DRAWING TITLE:

DRAWING STATUS: DRAWING NUMBER:

FOR INFORMATION

PROJECT NUMBER:

1902

ISSUE REVISION DETAILS INITIALS DATE

B RENOVATION PROPOSAL CC 17/10/2019

204

1:50

CC

TYPICAL GREEN HOUSE SECTION

1

-

SCALE: 1:250

GREENHOUSE TYPICAL SECTION

ONLY FOR INFORMATION

2

-

REFERENCE IMAGE FOR THE GREEN HOUSE

3

-

REFERENCE IMAGE FOR THE IRRIGATION SPRINKLER

0 10M 30M