SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 1/8Form 1021 (12.15) ©SOR Inc.
The T21 point level switch uses a thermal differential technique to measure liquid flow, level or interface by sensing changes in the thermal heat transfer characteristics of the media where it is located. The sensor consists of a pair of matched Resistance Temperature Detectors (RTDs) encased in twin 316 series stainless steel tubes. One RTD is self heated using a constant DC current. The other sensor is unheated and provides an accurate ambient process temperature reference. The thermal differential created between the heated and reference RTD pair is a function only of the media with which the sensor is in contact. The differential is greatest when no liquid is present (dry condition) and decreases as liquid quenches the switch sensors (wet condition).
Hydrocarbons generally have lower heat transfer characteristics than aqueous-based materials so liquid-liquid interface detection is possible. In general,
Low-Flow Alarm SwitchingSteel processors use water to cool bearings on the rollers of their continuous casting machines. If the casting machine loses water flow, the bearings will fail. Alarms are required to notify casting machine operators of this crucial loss of flow condition. The T21 flow switch is installed in each cooling water line to ensure this critical low-flow alarm.
The T21 can be used to monitor lube oil on bearings and gears in rolling mills; and since a single gear costs several hundred thousand dollars, its protection is vital to the operation of the plant.
The T21 can also monitor the flow of cooling water on pump seals in steel plants and furnaces.
Applications
any two media will exhibit some difference in heat transfer characteristics. Thus, this switch can be calibrated to detect the interface between two immiscible liquids. Solid state electronics transform the temperature differential into a voltage that is compared to a control voltage to actuate a relay and indicate a change in state (wet vs. dry). The instrument head at the top of the unit contains the switch electronics board which is easily removed form the instrument head so that field wiring can be connected to the field terminal block.
T21 Thermal Differential Switch for Detection of Level & Flow
SEE MORE AT SORInc.com
Request Quote
Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com2/8 Form 1021 (12.15) ©SOR Inc.
Low-Flow MonitoringIn food processing plants, there is a need to blend different ingredients. If one of the blending lines becomes clogged, the final product can be ruined due to improper blend balance. The T21 is perfect for this low-flow application. It monitors the flow and shuts down the blending system if an improper blending mix is about to occur. The highly reliable T21 has no moving parts and can be steam cleaned.
Applications
T21 Thermal Differential Switch
Waste Gas Burn-Flow MonitoringRemote pumping stations are often used in gas pipeline applications. In upset conditions, relief valves will open and the pumping station will produce waste gas as part of the pumping/compression operation. Waste gas is burned by the use of an auto-ignition flare. The EPA requires an alarm to sound if the flare does not ignite when gas flow is present. The T21 is directly mounted in the line to the flare, and determines when flow is present to provide the indication for the required alarm.
Vapor Recovery Hose Hook-Up VerificationThe T21 flow/level switch has the ideal features required to monitor vapor control in rugged environments. Mounted in the hard piping of the vapor recovery system, this switch detects the flow of vapors from the truck as loading begins. If the vapor hose connects properly, loading is allowed to continue. If the vapor hose does not properly connect, no flow is detected by the T21 and the loading process aborts. Finding reliable technology with low-flow sensitivity and fast response is critical for accurate monitoring of industrial emissions.
Monitoring Product Flow through Heat Exchangers The T21 flow switch can be utilized to protect heat exchangers in much the same way they are incorporated into pump systems. By monitoring the flow of product and actuating shut-off circuitry at a specified low-flow (or no-flow) point, the instruments can effectively prevent equipment and product damage caused by overheating.
SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 3/8Form 1021 (12.15) ©SOR Inc.
Features
T21 Thermal Differential Switch
Wide operating process temperature range of -100 to 392oF
Removable, plug-in electronics board
Free of all moving parts that can stick, coat or fail
Self-heating sensor design
Application flexibility
Simplifies wiring
High reliability
Improves response time and sensor durability
Input Power 115 VAC or 230 VAC, 50/60 Hz24 VDC (nominal)
Output Type 5A DPDT @ 250 VAC
Humidity 99% Non-condensing
Accuracy +0.5% of set point - 50oF range
Set Point Range Gases 0.5 to 500 feet/second(Flow) Liquids (Increasing) 0.01 to 5 feet/second (Decreasing) 0.01 to 2.5 feet/second
Repeatability +1.0% of set point
Response Time 0.5 to 10 seconds
Sensor Length 2 inches to 120 inches*
Enclosure Environmental Rating NEMA 4
Conduit Connection 3/4” NPT(F)
Stability Temperature compensated over entire range
Ambient Temperature Range -40 to 140oF (-40 to 60oC)
Process Temperature Range -100 to 392oF (-70 to 200oC)
Process Pressure Range Vacuum to 3000 psig
Agency Listing Rostechnadzor (RTN) standard (certificate available upon request)
Product Specifications
Agency Approval
Agency Approval
CSA Class I, Groups B, C, & D; Class II, Groups E, F, & G; Class III; Divisions 1 & 2
Design and specifications are subject to change without notice. For latest revision, see www.sorinc.com.
*Sensor lengths longer than 10”, please consult the factory.
Featu
res a
nd B
en
efits
Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com4/8 Form 1021 (12.15) ©SOR Inc.
Type 1
Integral Mounting
NEMA 4 EP (Single -Cavity)
2 Mounting
1
3 Housing
Process Variable 4
D
Level Process
Flow Process
Input Power
5A DPDT Output
2
D
5
6 Output Type
T21 thermal differential single point switch, integral mounting, NEMA 4 EP (single cavity) housing measuring overall liquid level, 24 VDC (4-wire) input power, 5-amp DPDT output, CSA explosion-proof, stainless steel tag wired to housing.
T21 - DL6D-CS-RRModel Number System
No Agency Approvals
CSA Explosion-Proof
7 Agency Approval*
Single-Point Switch
24 VDC (4-wire)
120 VAC
240 VAC
8 Accessories
Fiber Tag
Stainless Steel Tag Wired On
Certificates
Inspection Report
Compliance/Conformance
Dielectric Test
T 2 1 D L 6 D CS RR Model Number
*Match sensor approvals to electronics approvals to maintain the agency listing integrity.
How to Order
T21 Thermal Differential Switch
00
CS
L
F
PP
RR
C3
C4
C5
6
7
8
SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 5/8Form 1021 (12.15) ©SOR Inc.
Twin Tip
316/316L Stainless Steel Sensor
1 Sensor Style
EA
2Sensor Material2
Process Connection Size1 3
C
1 inch
3/4 inch
1
8
Process Connection Type
No Agency Approvals
CSA Explosion-Proof
A
00
CS
4
5 Agency Approval*
2 inches - 10 inches
6 Sensor Length in 1-inch Increments3
NPT(M)
T21 ThermalDifferential Switch How to Order
Twin tip, 316/316LSS sensor, 3/4 inch NPT(M) process connection, 6 inches in length, stainless steel tag wired to sensor.
EAC-8A-CS-6-RRModel Number System
1 Other process connections are available. Consult the factory.2 Other materials are available. Consult the factory.3 Longer lengths are available. Consult the factory.
*Match sensor approvals to electronics approvals to maintain the agency listing integrity.
7 Accessories
Fiber Tag
Stainless Steel Tag Wired On
Certificates
Typical Material of Wetted Parts
PP
RR
C8
EA C 8 A CS 6 RR Model Number
Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com6/8 Form 1021 (12.15) ©SOR Inc.
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certified drawings for a particular model number. Dimensions in this catalog are expressed as millimeters over inches. (Linear = mm/in.)
T21 ThermalDifferential Switch Dimensions
* Dimension is approximate and is based on a five-thread engagement.
ISO-9001
14685 W 105TH ST LENEXA, KS 66215 USA913-888-2630SORINC.COM
127.05.00
63.52.50
131.85.19
SENSOR LENGTH ± 1/8PER SALES ORDER
110.44.34
30.21.19
1.60.06
28.6 ACROSS FLATS1.13
34.81.37
B
A1
ELECTRONICS
PROCESSCONNECTION A B
1/2 NPTM 172.56.79
14.30.56
3/4 NPTM 156.06.14
19.10.75
1 NPTM 175.06.89
19.10.75
1-1/2 NPTM 173.76.84
19.10.75
2 NPTM 178.87.04
19.10.75
1 BSPTM 156.06.14
19.10.75
SENSOR LENGTH
DIMENSION APPROXIMATE AND BASEDON A FIVE THREAD ENGAGEMENT
ELECTRICALCONNECTION
3/4 NPTF STD1/2 NPTF OPT
M20 X 1.5F OPT
Model Name: 0390596.ASSEM/3/1+
PRODUCT CERTIFICATION DRAWINGALL DIMENSIONS ARE ±1/16 INUNLESS OTHERWISE SPECIFIED
MMLINEAR = IN
DRAWN BY
K MITCHELLCHECKED BY
M SMITHENGINEER APPROVAL
S BOALDATE
20 DEC 2011THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINEDHEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE
DIMENSION DRAWING THERMAL DISPERSIONWITH THREADED PROCESS CONNECTION
EO NUMBER: 4468
SCALE: 0.75
DO NOT SCALE PRINT
DRAWING NUMBER REV
0390596 3
SHEET 1 OF 1DWG SIZE
B
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #SALES PAGE
1
1
2X ELECTRICALCONNECTIONSEE TABLE
GROUND SCREW
PROCESSCONNECTIONSEE TABLE
1
Reset Form
Dimensions are for reference only. Contact the factory
for certified drawings for a particular model number.
Drawing 0390596
SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001 7/8Form 1021 (12.15) ©SOR Inc.
Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com8/8 Form 1021 (12.15) ©SOR Inc.
REGIONAL OFFICES
China
SOR China | Beijing, China
+86 (10) 5820 8767 | Fax +86 (10) 58 20 8770
Middle East
SOR Measurement & Control Equipment Trading DMCC | Dubai, UAE
+971 4 278 9632 | Fax +971 4 279 8399