SYSTEMS HardieSmart ZeroLot Wall System (Class 1 & 10a) Design Guide Australia October 2017 Make sure your information is up to date. When specifying or installing James Hardie products, ensure that you have the current technical information and guides. If in doubt, or you need more information, visit www.jameshardie.com.au or Ask James Hardie on 13 11 03. FRL 60/60/60 ONE WAY Rw 47-48 R 2.1 4.0 - 10 kN/m per wall per wall per wall per wall Certificate CM20136

SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

Embed Size (px)

Citation preview

Page 1: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

SYSTEMS

HardieSmart™ ZeroLot™ Wall System (Class 1 & 10a)

Design Guide

Australia October 2017

Make sure your information is up to date. When specifying or installing James Hardie™ products, ensure that you have the current technical information and guides. If in doubt, or you need more information, visit www.jameshardie.com.au or Ask James Hardie™ on 13 11 03.

FRL 60/60/60 ONE WAY

Rw 47-48

R 2.1

4.0 - 10 kN/m

per wall

per wall

per wall

per wall

Certificate CM20136

Page 2: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

CONTENTS

INTRODUCTION 3

MINIMUM REQUIREMENTS 3

APPLICATIONS 3

SYSTEM SPECIFICATION 4-5

System Configurations 4

System Performance (per wall) 4

Main Components 4

HardieZeroLot™ Panel Accessories 5

Fasteners (not supplied by James Hardie) 5

Sealants (not supplied by James Hardie) 5

Other (not supplied by James Hardie) 5

TOOLS 5

SAFE WORK PRACTICES 6

Fibre Cement 6

HardieFire™ Insulation 6

DESIGN CONSIDERATIONS 7-9 General 7

Slab and Footings 7

Termite Management 7

Boundary Setback 7

Fire Resistance 7

Bracing Performance 7

Thermal Performance 7

Weather Resistance 7

Coastal Areas 8

Fastener Type Limitation 8

Component Substitution 8

Framing 8

Services and Fixtures 9

Component Installation 9

CONSTRUCTION SEQUENCE 10-11

HARDIEZEROLOT™ PANEL 12-13 INSTALLATION STEPS

SYSTEM INSTALLATION STEPS 14-17

CONSTRUCTION DETAILS 18-28

Base Details 18

Floor Junctions 19

Roof Details 20-22

Wall Junctions 23-24

Wall Services 25-28

ONLINE TOOLS 29

WARRANTY 29

CODEMARK CERTIFICATION 29

Page 3: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 3 OF 32

DETACHED HOUSING | GARAGESCLASS

1 & 10a

HARDIESMARTTM ZEROLOTTM WALL SYSTEM DESIGN GUIDE APRIL2017 PAGE 1 OF 28

IntroductionThis guide contains product information, technical specification, construction details and design considerations for the HardieSmart™ ZeroLot™ Wall System.

What is a "Zero Lot" Line Home?When a building has one boundary wall built against the property line the house is said to have a virtually "zero lot" line. This is common in terrace style homes.

HardieSmart™ ZeroLot™ Wall System comprises two HardieSmart™ Boundary Walls built back to back with at least one built modularly. The external wall face is fitted with a specialised pre-sealed cladding known as HardieZeroLot™ Panel designed for areas with restricted access for maintenance.

Advantages• Creates more usable space within the lot.• Maximises indoor space using a compact solution.• Flexible building process: the construction of

independent structures, rather than traditionalsemi-detached buildings.

• Connection to adjoining properties is not requiredas the system is built and placed in modules.

Minimum RequirementsThe HardieSmart™ ZeroLot™ Wall System is designed for dual and single zero lot boundaries. It is suitable for use in Class 1 and 10a timber-framed buildings with a Fire Resistance Level (FRL) requirement of 60/60/60 minutes or less. For higher FRL, please consult James Hardie.

To provide you with the best possible solution, we continually seek to update and enhance our guides. PLEASE ENSURE YOU HAVE OUR LATEST GUIDE BEFORE USE by visiting jameshardie.com.au or calling on 13 11 03.

Design Guide

Dual Zero Lot (Detached Row Housing)

Single Zero Lot (Exterior Wall Against Existing Structure)

LOT A

LOT B

LOT C

Boundary Wall

60/60/60 FRL

Boundary Wall

60/60/60 FRL

INFILL LOT

Boundary Wall

60/60/60 FRL

Existing boundary

wall

Existing boundary

wall

WA

LL L

OT

B

WA

LL L

OT

C

NE

WW

ALL

WA

LL

Dual Exterior Walls

Single Exterior Wall

LOT A

LOT B

LOT C

Boundary Wall

60/60/60 FRL

Boundary Wall

60/60/60 FRL

INFILL LOT

Boundary Wall

60/60/60 FRL

Existing boundary

wall

Existing boundary

wall

WA

LLLO

TB

WA

LLLO

TC

NE

W W

ALL

EX

ISTI

NG

WA

LL

CLASS 1 & 10a DETACHED HOUSING | GARAGES AUSTRALIA | June 2017

ApplicationsTypical applications are depicted below. These are based on National Construction Code (NCC) 2016 Volume 2 and do not cover all applications and limitations, the designer must check all NCC requirements before specifying. If more information is required to assess suitability, please contact James Hardie.

Now with 60mmHardieFire™

Insulation

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 1 26/06/2017 10:41 AM

90x45/35mm Timber Studs

6mm Villaboard Lining

60mm HardieFire

Insulation

30mm service cavity

30mm service cavity

Servicesrefer to Design Considerions

HardieZeroLotPanel

ZEROLOT

HardieWrapWeather Barrier

Min 25mmseparation

Page 4: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 4 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 2 OF 28

System Specification

Dual Zero Lot

For fully detached row housing.

Single Zero Lot

For boundary walls built against existing walls

FRL 60/60/60 minutes

Total R-value 2.1 m2. K/W

Bracing 4.0-10.0 kN/m(depends on fixing method, refer to Design Considerations)

1 HardieZeroLot™ Panel

A fibre cement sheet with a ship lap joint along both 3000mm long edges. Pre-sealed with CoreShield™ technology and designed for unexposed maintenance-free applications.

Size (mm) 3000 x 1200 x 8.5Mass (kg/m2) 12Part No. 404880

2 HardieWrap® Weather Barrier

A non-perforated, highly breathable and reflective safe-glare weather barrier designed to be used behind cladding.

Length (mm) 2750 x 30,000Weight per roll (kg) 9Part No. / Coverage (m2)

305564 / 82.5

3 60mm HardieFire™ Insulation

Mineral wool insulation specifically designed for use in fire applications with select HardieSmart™ Systems. Pack Size: 7 batts

Size (mm) | Part No | Coverage (m2)

1160 x 560 | 305903 | 5.11160 x 420 | 305902 | 3.81320 x 420 | 305909 | 4.3

Thickness (mm) 60Material R-value (m2.K/W)

1.7

Density (kg/m3) 80

4 6mm Villaboard™ lining

Fibre cement internal lining sheet with a recessed edge. Suitable for tiled and untiled internal wall applications in dry and wet areas.

Sizes (mm) 900 x (2400, 3000)1200 x (1800, 2400, 2700, 3000, 3600, 4200)1350 x (2400, 3000, 3600, 4200)

Mass (kg/m2) 8.3Part No. See Villaboard™ lining manual

System Configurations

System Performance (per wall)

Main Components

See Design Considerations for framing specification, structural capacity, fire resistance and other limitations.

All dimensions and masses provided are approximate only and subject to manufacturing tolerances. Masses are based on equilibrium moisture content of product.

1

2

3 4

1

2

3

4

90mm Timber Stud Frame

90mm Stud Frame NEW

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 2 26/06/2017 10:41 AM

ONE WAY

Page 5: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 5 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 3 OF 28

James Hardie™ 9mm Aluminium Horizontal Step Flashing

A reversible aluminium flashing designed to be used at floor junctions and horizontal joints of HardieZeroLot™ panel.

Length (mm) 3600Pack Size 4 units per packPart No. 305886

James Hardie™ Aluminium 9mm External Corner

A ready to paint aluminium extrusion to be used at external corner junctions to conceal the board edge.

Size (mm) 3000Pack Size 5 units per packPart No. 305521

James Hardie™ 50mm wide Foam Back Sealing Tape

A self-adhesive foam tape to help improve water tightness. It is applied under sheet joins to the HardieWrap™ weather barrier along the stud face.

Length (m) 25Part No. 304560

HardieZeroLot™ Panel Accessories

Fasteners (not supplied by James Hardie)

Fibre Cement Nailfor fixing HardieZeroLot™ Panel and Villaboard™ lining

2.8 x 30mm min. Class 3 corrosion resistant fibre cement nail. 2.5 x 50mm gun nails are also suitable. Check with nail manufacturer for suitability.

Sealants (not supplied by James Hardie)

Fire and Acoustic-Rated Sealant

Use Bostik FireBan One fire rated sealant or equivalent. If using an equivalent sealant it must be tested in accordance with AS 1530.4 and achieve a minimum 60 minute fire rating. Contact the relevant sealant manufacturer for more information.

Other (not supplied by James Hardie)

Fire Resisting Mineral Wool

Used to seal cavities and maintain FRL at junctions of the selected wall system. Please see Construction Details for applications. Refer to manufacturer for guidance on installation.

ToolsReciprocating Saw or Hand Saw for cutting HardieFire™ Insulation

Used for cutting insulation when required. Ensure to cut 5mm wider than required to ensure compression of insulation in the cavity.

Tools For Fibre Cement

A suite of tools are available for cutting and handling James Hardie™ fibre cement. Please refer to James Hardie's Best Practice Guide for more information.

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 3 26/06/2017 10:41 AM

Page 6: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 6 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 4 OF 28

HardieFire™ Insulation

Electrical cables and services adjacent to HardieFire™ insulationFoil facings are conductive to electricity. Care must be taken when installing HardieFire™ insulation in the proximity of electrical wiring and lighting fixtures. Avoid contact with uninsulated electrical cables and fittings. If required, HardieFire™ foil facing may be removed using a utility knife. Consult a qualified Electrician, or contact James Hardie for further information.

Storage and Handling

Store in an internal dry area, out of direct sunlight and not exposed to chemicals. It must not be installed during an electrical storm and it must be installed in a dry state to a dry surface and protected from weather during transport and storage. HardieFire™ insulation has not been designed to withstand prolonged direct exposure to the exterior elements. Ensure that the insulation is completely dry prior to fitting.

Protective EquipmentKeep exposure to a minimum and minimise quantities kept in work areas. Avoid contact with eyes. When handling and installing HardieFire™ insulation, to prevent irritation ensure you wear:• Safety goggles/glasses conforming to AS/NZS

1336,• Protective clothing such as gloves and long

sleeve shirts and trousers,• P1 or P2 respirators.

Before Installation• You must turn the mains power ‘Off’ before

entering the workspace. If in doubt, you mustconsult a licensed electrician.

• Care and safety measures must be followedwhen working in areas that contain live electricalwiring.

• Defective electrical cables, terminals or any otherelectrical wiring must be repaired by the relevantspecialist prior to installation.

• Ensure workspace has adequate and ampleventilation. If working in confined spaces, it isrecommended to use a HEPA vacuum or othersuitable dust extractors.

• Before entering workspace, complete a riskassessment inspection to identify hazardsincluding but not limited to electrical, site accessand ventilation.

CuttingIt is recommended to cut outdoors. If cutting indoors, please ensure that workspace is properly ventilated or HEPA vacuums/dust extractors are used.1. Position cutting station so wind will blow dust

away from the user or others in working area.2. Use either a hand saw or a reciprocating saw.

DisposalDiscard any waste pieces of HardieFire™ insulation in accordance with your local council guidelines. Dispose of the material in such a manner to prevent exposure and escape.

Further Health and Safety InformationFor more information refer to the HardieFire™ insulation SDS available at jameshardie.com.au.

Safe Work Practices

James Hardie™ products contain sand, a source of respirable crystalline silica which is considered by some international authorities to be a cause of cancer from some occupational sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis, and has been linked with other diseases. During installation or handling, ensure to follow James Hardie's Best Practice Book and SDS for James Hardie™ fibre cement products available at www.jameshardie.com.au.

Fibre Cement

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 4 26/06/2017 10:41 AM

Page 7: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 7 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 5 OF 28

Design ConsiderationsGeneralAll design and construction must comply with the appropriate requirements of the NCC and other applicable regulations and standards. The specifier or other party responsible for the project must ensure that the details in this specification are appropriate for the intended application and that additional detailing is performed for specific design or any areas that fall outside the scope of this specification.

Slab and FootingsThe slab and footings on which the building is situated must comply with AS 2870 ‘Residential Slabs and Footings – Construction’ and the requirements of the NCC.SLAB SEPARATION: For detached construction, the designer must ensure that there is suitable slab separation between dwellings. This can be achieved by using a flexible bond breaking material (e.g. material for control joints) when setting out the slab. Refer to NCC and local regulations for more information.

Termite ManagementDue to restricted access at zero lot boundary walls, a suitable and certified termite management mechanism in accordance with AS 3660.1 or a reticulation system must be installed at the boundary slab e.g. Termimesh, Cordon and alike. Please consult the relevant manufacturer for more information.

Boundary SetbackThe HardieSmart™ ZeroLot™ Wall System specifies a minimum setback of 12.5mm from the boundary line when capped and installed in accordance with this guide.

When the HardieSmart™ ZeroLot™ Wall System is not capped and is built against an existing structure, a minimum setback of 500mm is recommended. Due to exposure, the HardieSmart™ ZeroLot™ panels will need to be coated and maintained in accordance with this guide (see coating section).

Please note that council, state or other regulations may apply in your development which specify different setbacks, height, width and other design criteria. Additionally, confirmation in writing in the form of a statutory declaration from the registered owner of the adjoining premises may be required to demonstrate compliance. The designer or specifier must ensure that the system is fit for purpose and complies with the relevant requirements and regulations.

Fire ResistanceNCC Vol. 2 Section 3.7.1 requires boundary walls to maintain an FRL of 60/60/60 minutes. HardieSmart™ Systems have been assessed by the CSIRO Division of Building Construction and Engineering and the Building Research Association of New Zealand (BRANZ) in accordance with the principles of AS1530.4 (FCO-3222 and FCO-3036 Rev. D).

Bracing PerformanceFor two sided systems i.e. comprising of both James Hardie™ external cladding and internal lining products of ≥6mm in thickness, the bracing capacity is typically 4 kN/m for plain timber framing and standard fixing methods. The capacity may be increased to a range of 6-10 kN/m for other fixing methods and anchor rods of 12mm diameter. For more information and specification, the designer must refer to James Hardie's Structural Bracing Application Guide(designed in accordance with AS 1684 'Residential Timber Framed Construction'). James Hardie's Structural Bracing Application Guide contains fixing details and the bracing capacity for James Hardie™

sheet bracing and other fibre cement cladding. All design capacities quoted are Ultimate Limit State(ULS) figures and have been certified by consulting engineers, Cardno (NSW) Pty Ltd.

Thermal PerformanceThis guide outlines certified modelled Total R-values for HardieSmart™ Wall Systems. Use this information to assist in satisfying the minimum deemed to satisfy NCC thermal resistance requirements and in verification software tools.

Total R-values are based on using HardieWrap™ weather barrier with an emissivity of 0.16W/m2. The Total R-values for common systems are in accordance with AS4859.1:2002 including Amendment 1:2006 'Materials for Thermal Insulation of Buildings'.

Weather ResistanceThe external cladding of the HardieSmart™ ZeroLot™ wall system has been designed in accordance with Clause P2.2.2 of the NCC. For any variations, it is the responsibility of the designer or specifier to identify moisture related risks associated with any particular building design. Wall construction design must effectively manage moisture, accounting for both the interior and exterior environments of the building, particularly in buildings that have a higher risk of wind-driven rain penetration or that are artificially heated or cooled. All wall openings, penetrations, intersections, connections, window sills, heads and jambs must be flashed prior to cladding installation.

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 5 26/06/2017 10:41 AM

HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 4 OF 28

HardieFire™ Insulation

Electrical cables and services adjacent to HardieFire™ insulationFoil facings are conductive to electricity. Care must be taken when installing HardieFire™ insulation in the proximity of electrical wiring and lighting fixtures. Avoid contact with uninsulated electrical cables and fittings. If required, HardieFire™ foil facing may be removed using a utility knife. Consult a qualified Electrician, or contact James Hardie for further information.

Storage and Handling

Store in an internal dry area, out of direct sunlight and not exposed to chemicals. It must not be installed during an electrical storm and it must be installed in a dry state to a dry surface and protected from weather during transport and storage. HardieFire™ insulation has not been designed to withstand prolonged direct exposure to the exterior elements. Ensure that the insulation is completely dry prior to fitting.

Protective EquipmentKeep exposure to a minimum and minimise quantities kept in work areas. Avoid contact with eyes. When handling and installing HardieFire™ insulation, to prevent irritation ensure you wear:• Safety goggles/glasses conforming to AS/NZS

1336,• Protective clothing such as gloves and long

sleeve shirts and trousers,• P1 or P2 respirators.

Before Installation• You must turn the mains power ‘Off’ before

entering the workspace. If in doubt, you mustconsult a licensed electrician.

• Care and safety measures must be followedwhen working in areas that contain live electricalwiring.

• Defective electrical cables, terminals or any otherelectrical wiring must be repaired by the relevantspecialist prior to installation.

• Ensure workspace has adequate and ampleventilation. If working in confined spaces, it isrecommended to use a HEPA vacuum or othersuitable dust extractors.

• Before entering workspace, complete a riskassessment inspection to identify hazardsincluding but not limited to electrical, site accessand ventilation.

CuttingIt is recommended to cut outdoors. If cutting indoors, please ensure that workspace is properly ventilated or HEPA vacuums/dust extractors are used.1. Position cutting station so wind will blow dust

away from the user or others in working area.2. Use either a hand saw or a reciprocating saw.

DisposalDiscard any waste pieces of HardieFire™ insulation in accordance with your local council guidelines. Dispose of the material in such a manner to prevent exposure and escape.

Further Health and Safety InformationFor more information refer to the HardieFire™ insulation SDS available at jameshardie.com.au.

Safe Work Practices

James Hardie™ products contain sand, a source of respirable crystalline silica which is considered by some international authorities to be a cause of cancer from some occupational sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis, and has been linked with other diseases. During installation or handling, ensure to follow James Hardie's Best Practice Book and SDS for James Hardie™ fibre cement products available at www.jameshardie.com.au.

Fibre Cement

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 4 26/06/2017 10:41 AM

Page 8: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 8 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 6 OF 28

Material Seasoned timber only. Timber used for house construction must have the level of durability appropriate for the relevant climate and expected service life. Must use minimum MGP10 or F7 grade timber. Reference AS1684 ‘Residential Timber Framed Construction.’

Stud Size

90 x (45 or 35)mm minimum HardieZeroLot™ panel requires minimum 45mm at vertical sheet joints, therefore, a double stud will be required. If 35mm studs are used, they must be fastened together.

Stud Spacing

600mm maximum Check whether you require closer stud spacings for your site wind pressures and tile weight (only for tiled walls). NOTE: HardieFire™ insulation sizes have been optimised for 45mm studs at 600mm centres and 35mm studs at 450mm centres, cutting may be required otherwise.

Nogging Spacing

1200mm maximum

Structural Capacity

4.3 kN/stud for 90 x 45mm @600mm centres or 35mm @450mm centres. For 35mm @600mm there is a reduced capacity of 3.0 kN/stud.The load bearing capacities of the timber-framed walls must be in accordance with AS1684 ‘Residential Timber-Framed Construction’ and AS1720.1 ‘Timber Structures’.

Stud Height (mm)

Stud Size Max. Height90 x 35mm 3000mm90 x 45mm 3600mm90 x 70mm 3900mm 90 x 90mm 4200mm

Stud Drilling

Where the stud is to be penetrated horizontally to allow services such as plumbing or electrical conduits to pass between stud bays, only 1 in every 5 studs may be drilled a maximum of 20mm in diameter 10mm from the edge (refer to Figure 35) in accordance with AS 1684 and AS1720.1. If larger or additional stud penetrations are required, then:Option 1: Limited Floor Span Refer to Figure 35 and ensure the following conditions are satisfied: • F7 or MGP10 timber grade• Zero Lot wall is exposed to wind

pressure, it does not exceed N2• Min. stud size 90x45mm• Drill studs within 500mm of stud ends• Limit the lower storey foor span to

5.8m (for MGP10) and 4.6m (F7). Notethat the load width of the Level 1 floorwhich bears onto an internal wall is thesum of the two adjacent

• spans divided by two for simplysupported construction

• Min. Wall height is 2400mmOption 2: Additional Stud

If conditions in Option 1 cannot be satisfied, then ensure to install a double stud as per AS1684. Refer to Figure 35

Coastal AreasIn areas within 1km of a coastal area, areas subject to salt spray and other corrosive environments, class 4 fasteners must be used. All other areas require a minimum class 3 fastener. Fasteners must be fully compatible with all other materials that they are in contact with to ensure the durability and integrity of the assembly. Contact the fastener manufacturer for more information.

Fastener Type LimitationBrad nail and/or adhesive fixings are not recommended in fire and acoustic-rated systems. Please refer to the respective product manufacturer for alternative fixing methods.

Component SubstitutionJames Hardie™ fibre cement products and components such as HardieFire™ insulation and HardieWrap™ weather barrier must be as specified in the system.

No statement of performance will be provided by James Hardie when alternative products are used.

Framing

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 6 26/06/2017 10:41 AM

Structural Capacity

The load bearing capacities of the timber-framed walls must be in accordance with AS1684 ‘Residential Timber-Framed Construction’ and AS1720 ‘Timber Structures’. Note: Sacrificial timber blocking is installed in addition to the required structural framing members and cannot be relied upon for any structural support.

Stud Size (mm)

Maximum Wall Height (mm)

Stud Load Capacity (kN/stud)

90x35 3000 3.1

90x45 3000 4.3

3600 2.9

90x70 3900 3.5

90x90 4200 3.6

Stud Drilling

Where the stud is to be penetrated horizontally to allow services such as plumbing or electrical conduits to pass between stud bays, only 1 in every 5 studs may be drilled a maximum of 20mm in diameter 10mm from the edge (refer to Figure 35) in accordance with AS 1684 and AS1720.1. If larger or additional stud penetrations are required, then:

Option 1: Limited Floor Span Refer to Figure 35 and ensure the following conditions are satisfied:• F7 or MGP10 timber grade• Zero Lot wall is exposed to wind pressure, it

does not exceed N2• Min. stud size 90x45mm• Drill studs within 500mm of stud ends• Limit the lower storey foor span to 5.8m

(for MGP10) and 4.6m (F7). Note that the load width of the Level 1 floor which bears onto an internal wall is the sum of the two adjacent

• spans divided by two for simply supported construction

• Min. Wall height is 2400mm

Option 2: Additional Stud If conditions in Option 1 cannot be satisfied, then ensure to install a double stud as per AS1684. Refer to Figure 35

Tolerance Ensure frame is square and work from a central datum line. Frames must be straight and true to provide a flush face to receive the sheeting. A suggested maximum tolerance of between 3mm and 4mm in any 3000mm length will give best results.

Page 9: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 9 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 7 OF 28

Component Installation

HardieWrap™ Weather Barrier

Refer to HardieWrap™ weather barrier datasheet for more information on standard installation. For modular construction, follow this guide.

HardieFire™ Insulation

Must be used as the frame cavity infill and must be compressed 5mm minimum in both vertical and horizontal directions (i.e. batt size must be at a minimum 5mm wider and longer than frame stud bay). Avoid joints in insulation batts, if present, all gaps must be filled with compressed HardieFire™ insulation. Position batts hard against external wall face to allow for an internal service cavity.

Villaboard™ Lining Must be installed in accordance with the current Villaboard™ lining installation guidelines.

HardieZeroLot™ Panel

Follow this guide.

Others For other components not supplied by James Hardie ensure to follow the instructions set out in this guide and the respective manufacturer's recommendations.

Services and FixturesThe service cavity is designed to allow services to be run vertically from the ceiling into the wall. Where services are run horizontally through the studs to pass between bays, refer to the ‘Framing’ section under Design Considerations and Figure 35 for installation guidelines.

Services may only be run in the service cavity between the insulation and the lining (i.e. must not exceed 20mm deep). WARNING: When fixing lining, avoid nailing near pipes or cables as it may cause damage.

Electrical Electrical cables may be run within the service cavity. Refer to Figures 36 to 38.

Plumbing and Electrical Conduits

Plumbing pipes with a diameter up to 20mm may be run in the service cavity as per Figure 35. Any larger pipes must be relocated to non-fire rated partitions. For taps and other details, refer to Figures 39-41.

Wall Fixtures

When fixing brackets, cabinets, shelves or any other fixture that requires the wall to carry a load, they must be fixed to the framing member (i.e. studs) and must not rely solely on the lining.

Air Conditioning

Pipes with an outside diameter up to 20mm and carrying non-flammable refrigerants may be run inside the service cavity.

Tolerance Ensure frame is square and work from a central datum line. Frames must be straight and true to provide a flush face to receive the sheeting. A suggested maximum tolerance of between 3mm and 4mm in any 3000mm length will give best results.

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 7 26/06/2017 10:41 AMHARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 7 OF 28

Component Installation

HardieWrap™ Weather Barrier

Refer to HardieWrap™ weather barrier datasheet for more information on standard installation. For modular construction, follow this guide.

HardieFire™ Insulation

Must be used as the frame cavity infill and must be compressed 5mm minimum in both vertical and horizontal directions (i.e. batt size must be at a minimum 5mm wider and longer than frame stud bay). Avoid joints in insulation batts, if present, all gaps must be filled with compressed HardieFire™ insulation. Position batts hard against external wall face to allow for an internal service cavity.

Villaboard™ Lining Must be installed in accordance with the current Villaboard™ lining installation guidelines.

HardieZeroLot™ Panel

Follow this guide.

Others For other components not supplied by James Hardie ensure to follow the instructions set out in this guide and the respective manufacturer's recommendations.

Services and FixturesThe service cavity is designed to allow services to be run vertically from the ceiling into the wall. Where services are run horizontally through the studs to pass between bays, refer to the ‘Framing’ section under Design Considerations and Figure 35 for installation guidelines.

Services may only be run in the service cavity between the insulation and the lining (i.e. must not exceed 20mm deep). WARNING: When fixing lining, avoid nailing near pipes or cables as it may cause damage.

Electrical Electrical cables may be run within the service cavity. Refer to Figures 36 to 38.

Plumbing and Electrical Conduits

Plumbing pipes with a diameter up to 20mm may be run in the service cavity as per Figure 35. Any larger pipes must be relocated to non-fire rated partitions. For taps and other details, refer to Figures 39-41.

Wall Fixtures

When fixing brackets, cabinets, shelves or any other fixture that requires the wall to carry a load, they must be fixed to the framing member (i.e. studs) and must not rely solely on the lining.

Air Conditioning

Pipes with an outside diameter up to 20mm and carrying non-flammable refrigerants may be run inside the service cavity.

Tolerance Ensure frame is square and work from a central datum line. Frames must be straight and true to provide a flush face to receive the sheeting. A suggested maximum tolerance of between 3mm and 4mm in any 3000mm length will give best results.

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 7 26/06/2017 10:41 AM

Sacrificial Timber

Sacrificial timber blocking is used in addition to the standard timber framing to protect structural members. Sacrificial timber should have minimum density of 550kg/m3. Where specified, differentiated by red hatching in the Construction Details section of this Guide, sacrificial timber blocks must be a minimum 45mm thick. Sacrificial timber blocks are to be arranged so that they are continuous. If blocks cannot be continuous, additional blocking must be provided in front of the joint. Reference FCO-3222, Figure 5 & Appendix B.6-B.7.

Page 10: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 10 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 8 OF 28

Construction SequenceWhen constructing a dual zero lot system, one external wall may be built with the standard construction method. The adjacent wall will need to be built in modules. Wall modules can be built in-situ or prefabricated by a specialised frame manufacturer for on-site assembly.

Provide slab separation between tenancies and install termite barrier. See Design Considerations.

Slab Separation

Upper Storey Modular Wall Roof TreatmentInstall HardieFire™ insulation and lining up to the roof linebefore installing roof trusses. See installation steps for modular construction.

Build, tilt, fix and brace wall modules.First Wall Construction

Repeat steps of lower storey; however, note that James Hardie™ Step Flashing is required at the floor junction.

1

2

4 5

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 8 26/06/2017 10:41 AM

Page 11: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 11 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 9 OF 28

Roof Treatment

Building First FloorSeveral options are available for joist treatment, refer to Construction Details and modular installation steps.

Install HardieFire™ insulation and lining up to the roof linebefore installing roof trusses. See installation steps for modular construction.

Build, tilt, fix and brace wall modules.First Wall Construction

Insulation, Lining and Services.Install HardieFire™ insulation, services and lining. Services are run vertically from the top or bottom plates, see Figure 35 for pipe installation instructions.

3

6

Existing or newly built wall in standard construction method (see p.10-11)

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 9 26/06/2017 10:41 AM

HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 8 OF 28

Construction SequenceWhen constructing a dual zero lot system, one external wall may be built with the standard construction method. The adjacent wall will need to be built in modules. Wall modules can be built in-situ or prefabricated by a specialised frame manufacturer for on-site assembly.

Provide slab separation between tenancies and install termite barrier. See Design Considerations.

Slab Separation

Upper Storey Modular Wall Roof TreatmentInstall HardieFire™ insulation and lining up to the roof linebefore installing roof trusses. See installation steps for modular construction.

Build, tilt, fix and brace wall modules.First Wall Construction

Repeat steps of lower storey; however, note that James Hardie™ Step Flashing is required at the floor junction.

1

2

4 5

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 8 26/06/2017 10:41 AM

Page 12: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 12 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 10 OF 28

HardieZeroLot™ Panel Installation Steps Unrestricted Site AccessStep 1 Frame PreparationConstruct frame to suit the site wind classification. Note that corners and junctions will require additional stud members. Refer to the relevant Construction Details.

TABLE 1 MAXIMUM STUD AND FASTENER SPACING AS PER AS4055

FIGURE 1 FRAME PREPARATION

Step 3 Foam TapeAt every vertical sheet join, a 50mm foam back sealing tape is applied under the shiplap vertical joint and in front of the HardieWrap™ weather barrier.

FIGURE 2 FOAM TAPE APPLICATION

Step 4 PositionHardieZeroLot™ panel must be installed vertically with all sheet edges fully supported. Centre of sheet joints must coincide with the centre line of the framing member and all sheets are installed in one direction. To ensure the fasteners fixed at the edge of the sheet have sufficient clearance from the edge, position the underlap sheet 3mm beyond the centre of the stud at every stud.

FIGURE 3 FIRST PANEL PLACEMENT

Step 2 Framing, Wrap and FlashingsEnsure that frame is straight. James Hardie recommends a maximum tolerance of 3mm in 3000mm. Affix HardieWrap™ weather barrier to frame followed by corner accessories.

Region N1-N4, C1-C2

N5, C3

N6, C4

Stud Spacing 600 450Panel Fastener Spacing 200 200 125

Ensure adequate ground clearance where required, min. 150mm

See Table 1

Install HardieWrap™ weather barrier, fix with staples at 450mm centres

Fix Corner Accessories in both flanges with a max. 300mm fastener spacing.

Remove protective seal from back of EPDM foam tape

50mm EPDM foam back sealing tape

45mm

18mm

90m

m ti

mbe

r st

ud

50mm EPDM foam back sealing tape

HardieWrap™ weather barrier

Position 3mm beyond stud centre line

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 10 26/06/2017 10:41 AM

Page 13: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 13 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 11 OF 28

Step 7 Fix Subsequent PanelsStep 5 Fix First PanelFix the first HardieZeroLot™ panel with the recommended nails as per Figure 4. Nails must be driven flush, do not overdrive.

Step 6 Apply Joint Sealant

FIGURE 4 FASTENER SPACING

FIGURE 5 APPLY JOINT SEALANT TO SHIPLAP JOINT

FIGURE 6 SECOND PANEL FASTENER CLEARANCE

Step 8 Coating (only for exposed areas)

HardieZeroLot™ panels are factory sealed with James Hardie's CoreShield™ technology penetrating sealer. This sealer has been designed for zero lot applications and does not require additional coating; however, for wall areas that are visible and fully exposed to the elements, you must apply a roll-on texture coat within 6 months of fixing. All sheets must be dry before painting. James Hardie recommends the application of a roll-on exterior texture coat system over the panels in accordance with the paint manufacturer’s specifications. Some environments require special coatings including coastal areas. Painting specifications are dependant on the paint chosen. Refer to the paint manufacturer for further information, product suitability, specifications, maintenance and details of their warranty.

18mm side edge clearance

12mm top edge clearance

See

Tab

le 1

50mm at corner

50mm EPDM foam back sealing tape

HardieWrap™ weather barrier

Continuous 4mm diameter bead of James Hardie™ Joint Sealant applied to underlap

Notch tip of sealant nozzle to act as a guide down the sheet edge

45mm

18mm

90m

m ti

mbe

r st

ud

50mm EPDM foam back sealing tape

HardieWrap™ weather barrier

6mm

See

Tab

le 1

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 11 26/06/2017 10:41 AM

HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 10 OF 28

HardieZeroLot™ Panel Installation Steps Unrestricted Site AccessStep 1 Frame PreparationConstruct frame to suit the site wind classification. Note that corners and junctions will require additional stud members. Refer to the relevant Construction Details.

TABLE 1 MAXIMUM STUD AND FASTENER SPACING AS PER AS4055

FIGURE 1 FRAME PREPARATION

Step 3 Foam TapeAt every vertical sheet join, a 50mm foam back sealing tape is applied under the shiplap vertical joint and in front of the HardieWrap™ weather barrier.

FIGURE 2 FOAM TAPE APPLICATION

Step 4 PositionHardieZeroLot™ panel must be installed vertically with all sheet edges fully supported. Centre of sheet joints must coincide with the centre line of the framing member and all sheets are installed in one direction. To ensure the fasteners fixed at the edge of the sheet have sufficient clearance from the edge, position the underlap sheet 3mm beyond the centre of the stud at every stud.

FIGURE 3 FIRST PANEL PLACEMENT

Step 2 Framing, Wrap and FlashingsEnsure that frame is straight. James Hardie recommends a maximum tolerance of 3mm in 3000mm. Affix HardieWrap™ weather barrier to frame followed by corner accessories.

Region N1-N4, C1-C2

N5, C3

N6, C4

Stud Spacing 600 450Panel Fastener Spacing 200 200 125

Ensure adequate ground clearance where required, min. 150mm

See Table 1

Install HardieWrap™ weather barrier, fix with staples at 450mm centres

Fix Corner Accessories in both flanges with a max. 300mm fastener spacing.

Remove protective seal from back of EPDM foam tape

50mm EPDM foam back sealing tape

45mm

18mm

90m

m ti

mbe

r st

ud

50mm EPDM foam back sealing tape

HardieWrap™ weather barrier

Position 3mm beyond stud centre line

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 10 26/06/2017 10:41 AM

Page 14: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 14 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 12 OF 28

Step 2 Set Out Slab or BaseInstall slab separation and termite management system in accordance with the Design Considerations section.

System Installation Steps Restricted Site Access

Step 1 Stage MaterialsThe components required for the HardieSmart™ ZeroLot™ Wall System must be staged during construction. Typically, a set of materials are required at framing stage and others at lining stage. The below lists do not consider all elements required for construction such as nails, adhesives, etc. Refer to the Accessories section for more information.

FRAMING STAGE: Involves building wall modules. These comprise of the following components:• Timber frame• HardieWrap™ weather barrier• HardieZeroLot™ panels• James Hardie™ Step Flashing• James Hardie™ 50mm wide Foam Back Sealing

Tape

NOTE: A small portion of HardieFire™ insulation may be required at framing stage for roof cavity, see installation sequence.

LINING STAGE:• HardieFire™ insulation• Villaboard™ lining• Fire and acoustic-rated joint sealant

FIGURE 7 SLAB SEPARATION

Step 3 Determine Wall Module SizeEnsure you have selected the optimum lengths and heights of wall modules. This is critical to achieve optimum speed of construction and ease of installation. Wall modules height and length should not exceed 3.6m. To determine wall module dimensions, you must consider the following:• HardieZeroLot™ panel sizes;• Boundary wall length and height (wall module must

not exceed storey height);• Module weight, please refer to Table 2.

When planning your wall module lengths, ensure cut edges are placed in the wall ends and intermediate modules are a multiple of the sheet width in length as the shiplap factory edge (Figure 8) is required for module jointing, refer to Figure 15.

TABLE 2 WALL MODULES WEIGHT FOR 600MM STUD CENTRE

Table Notes: Please note that masses and dimensions are approximate only. These are subjected to manufacturing tolerances and other factors such as moisture content. The weights listed below have been used in the values set out in Tables 3 and 4. It does not consider flashings, damp-proof course and any other elements not listed below:• Timber frame: 429 kg/m3. Assuming density of softwood

traditional pine timber studs with a moisture content of 16.2%, which may vary.

• HardieWrap™ weather barrier: 0.11kg/m2• HardieZeroLot™ panels: 12 kg/m2

FIGURE 8 WALL MODULE SIZE AND EDGES

Module Weight (kg)

Module Width (mm)1200 2400 3600 4800

Module Height(mm)

2400 41.5 81.3 121.0 160.82700 46.0 90.3 134.6 178.93000 50.6 99.4 148.2 197.13200 53.6 105.5 157.3 209.2

Concrete slab

Termite barrier in accordance with local regulations

20-5

0mm

10mm separation between slabs using flexible bond breaker

Fact

ory

edge

Fact

ory

edge

Fact

ory

edge

Fact

ory

edge

Cut

edg

es

Cut

edg

es

Sheet width

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 12 26/06/2017 10:41 AM

Page 15: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 15 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 13 OF 28

Step 4 Build Wall FramesBuild the frame modules on ground with maximum 600mm stud spacings. Add the required additional timber blocking at wall intersections.

Once pre-built, place the frame into position to check levelling. Ensure frame module is levelled and square (e.g. cross-braced).

FIGURE 10 LEVELLING WALL FRAMES

Step 6 HardieWrap™ Weather Barrier and Foam TapeAfter frames are levelled and braced, place back on the ground and install HardieWrap™ weather barrier. It is recommended to fix with a suitable hammer tacker and staples at 450mm centres. Overhang the wrap by min. 150mm from frame side edges. This is required when jointing wall modules, see Figure 15.

Step 5 Level & Brace

1. Ensure that on one end, the overlap of the HardieZeroLot™ panel is hanging off the frame by 25mm.

2. On the other end, the underlap should be 20mm inside the frame edge.

FIGURE 11 HARDIEWRAP™ INSTALLATION

Step 7 HardieZeroLot™ PanelsOn each module:

FIGURE 12 HARDIEZEROLOT™ PANEL INSTALLATION

FIGURE 9 SACRIFICIAL TIMBER AT WALL JUNCTIONS

See Figure 34 for Construction Detail

45x90mm sacrificial timber block at partition junction

HardieWrap™ weather barrier 50mm EPDM foam back sealing tape at sheet joins under shiplap (not required at wall ends)

90mm timber stud

150mm overhang

25mm overhang

A vertical sheet overhang may be required (see Figure 15 for options)

20mm underlap

50mm EPDM foam back sealing tape

HardieWrap™ weather barrier 150mm overhang from edge

HardieZeroLot ™ panel

Modulus width multiples of 1.2m

Shiplap joint

Install 9mm Aluminium Box Corner at wall ends (if 9mm James Hardie™ board is continued on return)

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 13 26/06/2017 10:41 AM

HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 12 OF 28

Step 2 Set Out Slab or BaseInstall slab separation and termite management system in accordance with the Design Considerations section.

System Installation Steps Restricted Site Access

Step 1 Stage MaterialsThe components required for the HardieSmart™ ZeroLot™ Wall System must be staged during construction. Typically, a set of materials are required at framing stage and others at lining stage. The below lists do not consider all elements required for construction such as nails, adhesives, etc. Refer to the Accessories section for more information.

FRAMING STAGE: Involves building wall modules. These comprise of the following components:• Timber frame• HardieWrap™ weather barrier• HardieZeroLot™ panels• James Hardie™ Step Flashing• James Hardie™ 50mm wide Foam Back Sealing

Tape

NOTE: A small portion of HardieFire™ insulation may be required at framing stage for roof cavity, see installation sequence.

LINING STAGE:• HardieFire™ insulation• Villaboard™ lining• Fire and acoustic-rated joint sealant

FIGURE 7 SLAB SEPARATION

Step 3 Determine Wall Module SizeEnsure you have selected the optimum lengths and heights of wall modules. This is critical to achieve optimum speed of construction and ease of installation. Wall modules height and length should not exceed 3.6m. To determine wall module dimensions, you must consider the following:• HardieZeroLot™ panel sizes;• Boundary wall length and height (wall module must

not exceed storey height);• Module weight, please refer to Table 2.

When planning your wall module lengths, ensure cut edges are placed in the wall ends and intermediate modules are a multiple of the sheet width in length as the shiplap factory edge (Figure 8) is required for module jointing, refer to Figure 15.

TABLE 2 WALL MODULES WEIGHT FOR 600MM STUD CENTRE

Table Notes: Please note that masses and dimensions are approximate only. These are subjected to manufacturing tolerances and other factors such as moisture content. The weights listed below have been used in the values set out in Tables 3 and 4. It does not consider flashings, damp-proof course and any other elements not listed below:• Timber frame: 429 kg/m3. Assuming density of softwood

traditional pine timber studs with a moisture content of 16.2%, which may vary.

• HardieWrap™ weather barrier: 0.11kg/m2• HardieZeroLot™ panels: 12 kg/m2

FIGURE 8 WALL MODULE SIZE AND EDGES

Module Weight (kg)

Module Width (mm)1200 2400 3600 4800

Module Height(mm)

2400 41.5 81.3 121.0 160.82700 46.0 90.3 134.6 178.93000 50.6 99.4 148.2 197.13200 53.6 105.5 157.3 209.2

Concrete slab

Termite barrier in accordance with local regulations

20-5

0mm

10mm separation between slabs using flexible bond breaker

Fact

ory

edge

Fact

ory

edge

Fact

ory

edge

Fact

ory

edge

Cut

edg

es

Cut

edg

es

Sheet width

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 12 26/06/2017 10:41 AM

Page 16: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 16 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 14 OF 28

Step 9 Temporary Bracing

Step 8 Lift First Wall ModuleWall modules may be lifted manually or by crane (this will depend on the module size and weight). If craning modules into position, the lifting points and connections must be designed by the relevant specialist in accordance with the relevant codes and practices. Ensure to anchor frame to slab as per frame manufacturer recommendations.

Place adequate temporary bracing to ensure lateral restraint of the modules.

Step 10 Subsequent Wall Modules

FIGURE 13 LIFT AND ANCHOR - WALL MODULES

FIGURE 14 LIFT AND ANCHOR - WALL MODULES

Step 11 Jointing Wall Modules

Repeat steps 4-9.

FIGURE 15 VERTICAL JOINT OF WALL MODULES

Step 12 Floor JunctionPlace sacrificial timber at the floor junction prior to resting the floor joist on 45mm bearing or fix pole plate to continuous wall.

FIGURE 16 INSTALLING FLOOR JOISTS

Option 1See Figure 24

See Figure 25Option 2

Hei

ght o

f joi

st

Shiplap joint

Suitable sarking tape

Wrap HardieWrap™ weather barrier and tape to studs

45mm solid sacrificial timber blocking

Parallel or perpendicular floor joists with max. 45mm bearing on top plate of frame

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 14 26/06/2017 10:41 AM

Page 17: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 17 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 15 OF 28

Step 13 Step Flashing

Step 14 Upper Storey

Step 15 Roof Cavity

Step 16 Fix HardieFire™ InsulationAfter the partitions and floor boards have been installed and the upper storey is accessible, fix James Hardie™ Step Flashing to the structural flooring board as indicated below.

FIGURE 17 INSTALLING STEP FLASHING

Repeat steps 3-11 for the upper storey, note that wall modules must extend to the roof line. Refer to Construction Details for roof options.

Based on your roof construction detail follow the appropriate detail (See Figures 26-31). Ensure to fix Villaboard™ lining and HardieFire™ insulation prior to fixing the roof trusses to the wall.

FIGURE 18 ROOF CAVITY FIXING

Install the HardieFire™ insulation within stud bays with at least 5mm compression. Avoid joints in insulation batts, if present, all gaps must be filled with compressed HardieFire™ insulation. Push insulation all the way against the HardieWrap™ weather barrier. ENSURE TO FOLLOW BEST PRACTICE AND WEAR APPROPRIATE PROTECTIVE EQUIPMENT.

FIGURE 19 HARDIEFIRE™ INSTALLATION

FIGURE 21 VILLABOARD™ LINING INSTALLATION

Step 17 Fix Villaboard™ LiningVillaboard™ lining to be installed in accordance with the current installation manual. See Figures

26-31 for options

Step 17 Install ServicesServices to be run vertically from the ceiling into the wall within the stud bay. If stud drilling is required to allow for pipes or conduits, refer to Figure 35 for instructions. Do not penetrate insulation.

Step Flashing, fixed to structural flooring at 300mm centres overlapping bottom HardieZeroLot™ panel

Structural flooring

Floor joist

Parallel or perpendicular roof trusses or frames

HardieFire™ insulation in stud bays underneath cladding

Fit 60mm HardieFire™ insulation to back of stud bay, leaving 30mm clearance for services

Fix Villaboard™ lining at 200mm fixing centres around the edges and 300mm centres through the middle.

FIGURE 20 INSTALLATION OF SERVICES

Refer to Figures 35-41for Construction Details

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 15 26/06/2017 10:41 AM

HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 14 OF 28

Step 9 Temporary Bracing

Step 8 Lift First Wall ModuleWall modules may be lifted manually or by crane (this will depend on the module size and weight). If craning modules into position, the lifting points and connections must be designed by the relevant specialist in accordance with the relevant codes and practices. Ensure to anchor frame to slab as per frame manufacturer recommendations.

Place adequate temporary bracing to ensure lateral restraint of the modules.

Step 10 Subsequent Wall Modules

FIGURE 13 LIFT AND ANCHOR - WALL MODULES

FIGURE 14 LIFT AND ANCHOR - WALL MODULES

Step 11 Jointing Wall Modules

Repeat steps 4-9.

FIGURE 15 VERTICAL JOINT OF WALL MODULES

Step 12 Floor JunctionPlace sacrificial timber at the floor junction prior to resting the floor joist on 45mm bearing or fix pole plate to continuous wall.

FIGURE 16 INSTALLING FLOOR JOISTS

Option 1See Figure 24

See Figure 25Option 2

Hei

ght o

f joi

st

Shiplap joint

Suitable sarking tape

Wrap HardieWrap™ weather barrier and tape to studs

45mm solid sacrificial timber blocking

Parallel or perpendicular floor joists with max. 45mm bearing on top plate of frame

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 14 26/06/2017 10:41 AM

Page 18: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 18 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 16 OF 28

Construction DetailsBase Details

FIGURE 22 SLAB DETAIL FOR DUAL BOUNDARY SYSTEM

FIGURE 23 SLAB DETAIL FOR SINGLE BOUNDARY

6mm James Hardie™ internal lining

90mm stud

60mm HardieFire™ insulation

HardieZeroLot™ panel

6mm gap fully caulked with fire-rated sealant

Slab separation in accordance with NCC requirements and local regulations (see Design Considerations)

20-50mm

Termite barrier in accordance with local regulations

Damp proof course

HardieWrap™ weather barrier

Boundary line

6mm James Hardie™ internal lining

90mm stud

60mm HardieFire™ insulation

HardieZeroLot™ panel

6mm gap fully caulked with fire-rated sealant

Boundary line

Damp proof courseHardieWrap™ weather barrier

Exi

stin

g n

eig

hbo

urin

g w

all

Slab separation and termite barriers in accordance with local regulations

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 16 26/06/2017 10:41 AM

Page 19: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 19 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 17 OF 28

Floor Junctions

FIGURE 24 DISCONTINUOUS WALL FLOOR JUNCTION (RECOMMENDED)

FIGURE 25 CONTINUOUS WALL FLOOR JUNCTION

6mm James Hardie™ internal lining

60mm HardieFire™ insulation HardieWrap™ weather barrier

Structural flooring

45mm continuous sacrificial timber blocking behind joists

PERPENDICULAR FLOOR JOIST

PERPENDICULAR FLOOR JOIST

PARALLEL FLOOR JOIST

PARALLEL FLOOR JOIST

45mm continuous sacrificial timber blocking

Non fire-rated ceiling lining

Plaster cornice

60mm HardieFire™ insulation

Structural flooring

Non fire-rated ceiling lining

Plaster cornice

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

James Hardie™ Step Flashing

James Hardie™ Step Flashing

Gap must not exceed 25mm and must be covered by cornice

Gap must not exceed 25mm and must be covered by cornice

HardieZeroLot™ panel

HardieZeroLot™ panel

HardieWrap™ weather barrier

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 17 26/06/2017 10:41 AM

HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 16 OF 28

Construction DetailsBase Details

FIGURE 22 SLAB DETAIL FOR DUAL BOUNDARY SYSTEM

FIGURE 23 SLAB DETAIL FOR SINGLE BOUNDARY

6mm James Hardie™ internal lining

90mm stud

60mm HardieFire™ insulation

HardieZeroLot™ panel

6mm gap fully caulked with fire-rated sealant

Slab separation in accordance with NCC requirements and local regulations (see Design Considerations)

20-50mm

Termite barrier in accordance with local regulations

Damp proof course

HardieWrap™ weather barrier

Boundary line

6mm James Hardie™ internal lining

90mm stud

60mm HardieFire™ insulation

HardieZeroLot™ panel

6mm gap fully caulked with fire-rated sealant

Boundary line

Damp proof courseHardieWrap™ weather barrier

Exi

stin

g n

eig

hbo

urin

g w

all

Slab separation and termite barriers in accordance with local regulations

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 16 26/06/2017 10:41 AM

Additional structural blocking if required. Refer to Framing

Design Considerations.

Where sacrificial timber cannot be discontinuous, solid timber joist is required

Page 20: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 20 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 18 OF 28

Roof Details

FIGURE 26 DUAL ZERO LOT ROOF WITH PARALLEL ROOF TRUSSES

FIGURE 27 DUAL ZERO LOT PARAPET ROOF WITH PARALLEL ROOF TRUSSES

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

HardieFire™ insulation

Suitable fire resistant mineral wool insulation to maintain FRL (HardieFire™

insulation not suitable)

Suitable corrosion resistant capping

Perimeter support

Roof sheeting or tiles installed in accordance with manufacturer instructions

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

6mm gap fully caulked with fire-rated sealant

60mm HardieFire™ insulation

Suitable corrosion resistant flashing and capping

Parallel roof truss attached to timber stud

Perimeter support

Roof sheeting or tiles installed in accordance with manufacturer instructions

6mm James Hardie™ internal lining

6mm James Hardie™ internal lining

Gap must not exceed 25mm and must be covered by cornice

HardieWrap™ weather barrier

Boundary line

HardieZeroLot™ panel

90mm stud

HardieWrap™ weather barrier

HardieZeroLot™ panel

Boundary line

90mm stud

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 18 26/06/2017 10:42 AM

Page 21: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 21 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 19 OF 28

FIGURE 28 DUAL ZERO LOT FRAMED ROOF PERPENDICULAR

FIGURE 29 DUAL ZERO LOT PARAPET ROOF WITH PERPENDICULAR TRUSSES

Roof sheeting or tiles installed in accordance with manufacturer instructions

Suitable fire resistant mineral wool insulation to maintain FRL (HardieFire™ insulation not suitable)

6mm James Hardie™ internal lining (joints not set)

60mm HardieFire™ insulation

60mm HardieFire™ insulation

45mm continuous sacrificial timber blocking

to maintain FRL

Suitable corrosion resistant capping

45mm solid timber pole plate

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

Suitable corrosion resistant capping

Roof sheeting or tiles installed in accordance with manufacturer instructions

Extend metal capping over box gutter upstand to fully protect lining from moisture

Ceiling lining

Ceiling lining

6mm James Hardie™ internal lining (joints not set)

Suitable box gutter, 50mm + height of water

Gap must not exceed 25mm and must be covered by cornice

Gap must not exceed 25mm and must be covered by cornice

HardieWrap™ weather barrier HardieZeroLot™ panel 6mm James Hardie™ internal lining

90mm stud

Boundary line

45mm solid timber pole plate

HardieWrap™ weather barrier

HardieZeroLot™ panel

Boundary line90mm stud

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 19 26/06/2017 10:42 AM

HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 18 OF 28

Roof Details

FIGURE 26 DUAL ZERO LOT ROOF WITH PARALLEL ROOF TRUSSES

FIGURE 27 DUAL ZERO LOT PARAPET ROOF WITH PARALLEL ROOF TRUSSES

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

HardieFire™ insulation

Suitable fire resistant mineral wool insulation to maintain FRL (HardieFire™

insulation not suitable)

Suitable corrosion resistant capping

Perimeter support

Roof sheeting or tiles installed in accordance with manufacturer instructions

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

6mm gap fully caulked with fire-rated sealant

60mm HardieFire™ insulation

Suitable corrosion resistant flashing and capping

Parallel roof truss attached to timber stud

Perimeter support

Roof sheeting or tiles installed in accordance with manufacturer instructions

6mm James Hardie™ internal lining

6mm James Hardie™ internal lining

Gap must not exceed 25mm and must be covered by cornice

HardieWrap™ weather barrier

Boundary line

HardieZeroLot™ panel

90mm stud

HardieWrap™ weather barrier

HardieZeroLot™ panel

Boundary line

90mm stud

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 18 26/06/2017 10:42 AM

Page 22: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 22 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 20 OF 28

FIGURE 30 DUAL ZERO LOT ROOF WITH PERPENDICULAR TRUSSES AND BOX GUTTER

FIGURE 31 DUAL ZERO LOT ROOF AT DIFFERENT HEIGHTS

45mm solid continuous sacrificial timber

6mm James Hardie™ internal lining

90mm stud 60mm HardieFire™ insulation

HardieWrap™ weather barrier

Corrosion resistant metal flashing to

seal cavity

Roof sheeting or tiles installed in accordance with manufacturer instructions

Ceiling lining

Bottom chords extendedtimber continuous blocking(refer to truss manufacturer)

Timber packers. Any gaps must be filled with fire resistant mineral wool to maintain FRL of wall system (HardieFire™ insulation is not suitable)

HardieWrap™ weather barrier

Suitable corrosion resistant apron flashing to seal cavity

Roof sheeting or tiles installed in accordance with manufacturer instructions

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

Ceiling lining

HardieWrap™ weather barrier

90mm stud

Gap must not exceed 25mm and must be covered by cornice

Gap must not exceed 25mm and must be covered by cornice

HardieZeroLot™ panel

HardieZeroLot™ panel

Suitable corrosion resistant capping

Suitable fire resistant mineral wool insulation to maintain FRL (HardieFire™ insulation not suitable)

Boundary line

HardieZeroLot™ panel

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 20 26/06/2017 10:42 AM

Page 23: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 23 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 21 OF 28

Wall Junctions

FIGURE 32 JUNCTION WITH LIGHTWEIGHT EXTERNAL WALL

FIGURE 33 JUNCTION WITH BRICK VENEER WALL

6mm gap fully caulked with fire-rated sealant

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

HardieWrap™ weather barrier

90mm stud

HardieWrap™ weather barrier

Axent™ Trim or suitable corner accessory

Selected external cladding

75x75mm James Hardie™ corner flashing

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

HardieWrap™ weather barrier

90mm stud

6mm gap fully caulked with fire-rated sealant

HardieWrap™ weather barrier

Suitable fire resistant mineral wool insulation to maintain FRL (HardieFire™ insulation not suitable)

Brick articulation joint in accordance with manufacturer instructions Corrosion resistant flashing

HardieZeroLot™ panel

Boundary line

HardieZeroLot™ panel

Boundary line

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 21 26/06/2017 10:42 AM

Non fire-rated internal lining

45mm continuous sacrificial timber blocking, extending from bottom to top plate

Non fire-rated internal lining

45mm continuous sacrificial timber stud, extending from bottom to top plate

HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 20 OF 28

FIGURE 30 DUAL ZERO LOT ROOF WITH PERPENDICULAR TRUSSES AND BOX GUTTER

FIGURE 31 DUAL ZERO LOT ROOF AT DIFFERENT HEIGHTS

45mm solid continuous sacrificial timber

6mm James Hardie™ internal lining

90mm stud 60mm HardieFire™ insulation

HardieWrap™ weather barrier

Corrosion resistant metal flashing to

seal cavity

Roof sheeting or tiles installed in accordance with manufacturer instructions

Ceiling lining

Bottom chords extendedtimber continuous blocking(refer to truss manufacturer)

Timber packers. Any gaps must be filled with fire resistant mineral wool to maintain FRL of wall system (HardieFire™ insulation is not suitable)

HardieWrap™ weather barrier

Suitable corrosion resistant apron flashing to seal cavity

Roof sheeting or tiles installed in accordance with manufacturer instructions

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

Ceiling lining

HardieWrap™ weather barrier

90mm stud

Gap must not exceed 25mm and must be covered by cornice

Gap must not exceed 25mm and must be covered by cornice

HardieZeroLot™ panel

HardieZeroLot™ panel

Suitable corrosion resistant capping

Suitable fire resistant mineral wool insulation to maintain FRL (HardieFire™ insulation not suitable)

Boundary line

HardieZeroLot™ panel

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 20 26/06/2017 10:42 AM

Page 24: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 24 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 22 OF 28

FIGURE 34 INTERNAL NON FIRE-RATED WALL JUNCTION

6mm gap fully caulked with fire-rated sealant

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

90mm stud

Non fire-rated internal lining

45mm continuous sacrificial timber stud, extending from bottom to top plate

HardieZeroLot™ panel

HardieWrap™ weather barrier

Boundary line

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 22 26/06/2017 10:42 AM

2 x additional timber studs

HA

RD

IES

MA

RT

TM Z

ER

OLO

T™

WA

LL S

YS

TE

M D

ES

IGN

GU

IDE

AP

RIL

2017 P

AG

E 2

2 O

F 2

8

FIG

UR

E 3

4 IN

TE

RN

AL N

ON

FIR

E-R

AT

ED

WA

LL J

UN

CT

ION

6m

m g

ap

fully

caulk

ed

w

ith fi

re-r

ate

d s

eala

nt

6m

m J

am

es

Hard

ie™

inte

rnal l

inin

g

60

mm

Hard

ieFire

™ in

sula

tion

90

mm

stu

d

No

n fi

re-r

ate

d

inte

rnal l

inin

g

45

mm

co

ntin

uo

us

sacrif

icia

l tim

ber

stud

, ext

end

ing

fro

m

bo

tto

m t

o t

op

pla

te

HardieZeroLot™

panel

Hard

ieW

rap

weath

er

barr

ier

Bo

und

ary

line

2207

-63_

JH_H

ardi

eSm

art_

Zero

lot_

Des

ign_

Gui

de_2

A_P

P.in

dd

2226

/06/

2017

10

:42

AM

2 x

ad

diti

onal

timb

er

stud

s

HA

RD

IES

MA

RT

TM Z

ER

OLO

T™

WA

LL S

YS

TE

M D

ES

IGN

GU

IDE

AP

RIL

2017 P

AG

E 2

2 O

F 2

8

FIG

UR

E 3

4 IN

TE

RN

AL N

ON

FIR

E-R

AT

ED

WA

LL J

UN

CT

ION

6m

m g

ap

fully

caulk

ed

w

ith fi

re-r

ate

d s

eala

nt

6m

m J

am

es

Hard

ie™

inte

rnal l

inin

g

60

mm

Hard

ieFire

™ in

sula

tion

90

mm

stu

d

No

n fi

re-r

ate

d

inte

rnal l

inin

g

45

mm

co

ntin

uo

us

sacrif

icia

l tim

ber

stud

, ext

end

ing

fro

m

bo

tto

m t

o t

op

pla

te

HardieZeroLot™

panel

Hard

ieW

rap

weath

er

barr

ier

Bo

und

ary

line

2207

-63_

JH_H

ardi

eSm

art_

Zero

lot_

Des

ign_

Gui

de_2

A_P

P.in

dd

2226

/06/

2017

10

:42

AM

2 x

ad

diti

onal

timb

er

stud

s

Page 25: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 25 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 23 OF 28

FIGURE 35 PIPE SERVICE PENETRATIONS THROUGH TIMBER STUDS AND PLATES

Wall Services

Install additional 45mm timber block

Max. 20mm drill or notch

Max. 20mm drill or notch

5 Studs

Step 3 (if required)If stud drilling for more than 1 in every 5 studs is required to pass pipes, a restricted drill height must be followed (Option 1) or alternatively, a fixeddouble stud (Option 2) isinstalled.

Step 4Treat the pipe wall exit in accordance with the relevant Construction Detail in this guide.

* Option 1 has a minimum wall height of 2400mm, minimum stud width of 45mm and a limited allowable lower storey floor span of 6m for MGP10 timber grade and 5m for F7 timber grade. For other grades or timber sizes Option 2 must be followed. Refer to Design Considerations for more information or contact James Hardie Engineering Solutions on 13 11 03.

Step 1Run all pipes and conduits through ceiling or floor.

Step 2Drill or notch (max. 20mm) top/bottom plate to run the pipes into the required stud bay.

DRILLING THE PLATE

DRILLING STUDS

OP

TIO

N 1

* (4

5mm

stu

d)

OP

TIO

N 2

DRILLING BOTTOM PLATE

Ceiling lining

Structural floor

HOLE CLEARANCE

90mm

Max 20mm

10mm

Min. 270mm

500m

m

DR

ILL

CLE

AR

AN

CE

DR

ILL

500m

m

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 23 26/06/2017 10:42 AM

HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 22 OF 28

FIGURE 34 INTERNAL NON FIRE-RATED WALL JUNCTION

6mm gap fully caulked with fire-rated sealant

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

90mm stud

Non fire-rated internal lining

45mm continuous sacrificial timber stud, extending from bottom to top plate

HardieZeroLot™ panel

HardieWrap™ weather barrier

Boundary line

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 22 26/06/2017 10:42 AM

2 x additional timber studs

Page 26: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 26 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 24 OF 28

FIGURE 36 ELECTRICAL SERVICES (GPO/POWER POINTS) - SECTION FROM ABOVE

Standard GPO installed in accordance with manufacturer's instructions

6mm gap fully caulked

with fire-rated sealant

Pin cables to the side

HardieWrap™ weather barrier

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

90mm stud

Drill or notch through stud to run cables where necessary.

WARNING: Avoid foil contact with uninsulated cables and fittings, refer to Safety Section for more information

HardieZeroLot™

panel

FIGURE 37 ELECTRICAL SERVICES (GPO/POWER POINTS) - SECTION FROM SIDE

HardieWrap™ weather barrier

60mm HardieFire™ insulation

Bracket for power point fixed to stud

Electrical cables pinned or taped to stud where required

Standard GPO installed in accordance with manufacturer's instructions

6mm James Hardie™ internal lining

WARNING: Avoid foil contact with uninsulated cables and fittings, refer to Safety Section for more information.

HardieZeroLot™ panel

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 24 26/06/2017 10:42 AM

Page 27: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 27 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 25 OF 28

FIGURE 38 ELECTRICAL SERVICES (GPO/POWER POINTS) PERSPECTIVE

Standard GPO installed in accordance with manufacturer's instructions

Bracket for powerpoint fixed to stud

Cables pinned to stud edges

6mm James Hardie™ internal

lining

60mm HardieFire™

insulation

WARNING: Avoid foil contact with uninsulated cables and fittings, refer to Safety Section for more information.

FIGURE 39 HOT/COLD PLUMBING TAPS - PERSPECTIVE

Selected James Hardie™ external cladding 6mm thick or greater

Plumbing services run vertically through 30mm service cavity.

6mm Villaboard™ lining installed, waterproofed and tiled as per Wet Area Construction Guide

90x45mm additional timber noggin for tap support. Insert nogging prior to HardieFire™ insulation

60mm HardieFire™ insulation

Continuous 6mm bead of wet area appropriate fire-rated sealant around tap

HardieWrap™ weather barrier

WARNING: When fixing lining, avoid nailing near pipes or cables as it may cause damage. Refer to Figure 35 for plate and stud penetration details.

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 25 26/06/2017 10:42 AM

HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 24 OF 28

FIGURE 36 ELECTRICAL SERVICES (GPO/POWER POINTS) - SECTION FROM ABOVE

Standard GPO installed in accordance with manufacturer's instructions

6mm gap fully caulked

with fire-rated sealant

Pin cables to the side

HardieWrap™ weather barrier

6mm James Hardie™ internal lining

60mm HardieFire™ insulation

90mm stud

Drill or notch through stud to run cables where necessary.

WARNING: Avoid foil contact with uninsulated cables and fittings, refer to Safety Section for more information

HardieZeroLot™

panel

FIGURE 37 ELECTRICAL SERVICES (GPO/POWER POINTS) - SECTION FROM SIDE

HardieWrap™ weather barrier

60mm HardieFire™ insulation

Bracket for power point fixed to stud

Electrical cables pinned or taped to stud where required

Standard GPO installed in accordance with manufacturer's instructions

6mm James Hardie™ internal lining

WARNING: Avoid foil contact with uninsulated cables and fittings, refer to Safety Section for more information.

HardieZeroLot™ panel

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 24 26/06/2017 10:42 AM

Page 28: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 28 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 26 OF 28

FIGURE 41 HOT/COLD PLUMBING TAPS - SECTION FROM SIDE

HardieWrap™ weather barrier

60mm HardieFire™ insulationPlumbing services

run vertically through 30mm service cavity.

6mm Villaboard™ lining installed, waterproofed

and tiled as per Wet Area Construction Guide

90x45mm additional timber noggin for tap support. Insert nogging prior to HardieFire™ insulation

Continuous 6mm bead of wet area appropriate fire-rated sealant around tap

WARNING: When fixing lining, avoid nailing near pipes or cables as it may cause damage. Refer to Figure 35 for plate and stud penetration details.

HardieZeroLot™ panel

FIGURE 40 HOT/COLD PLUMBING TAPS - SECTION FROM ABOVE

HardieWrap™ weather barrier

Plumbing services run through 30mm service cavity

6mm Villaboard™ lining installed, waterproofed and tiled as per Wet Area Construction Guide

Refer to Figure 35 for drill hole size and location

90x45mm additional timber noggin for tap support. Insert nogging prior to HardieFire™ insulation

Continuous 6mm bead of wet area appropriate fire-rated sealant around tap

WARNING: When fixing lining, avoid nailing near pipes or cables as it may cause damage. Refer to Figure 35 for plate and stud penetration details.

HardieZeroLot™

panel

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 26 26/06/2017 10:42 AM

Page 29: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 29 OF 32HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 27 OF 28

Online ToolsEstimation tools, CAD details, and site specific documents are available via James Hardie's specification website accel.com.au. For more information visit the www.jameshardie.com.au or Ask James Hardie™ on 13 11 03

WarrantyHardieSmart™ Wall System components supplied by James Hardie are backed by a Warranty. The Warranty period will vary based on the specific system component. For Warranty Terms & Conditions refer to www.jameshardie.com.au or Ask James Hardie™ on 13 11 03.

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 27 26/06/2017 10:42 AM

HARDIESMARTTM ZEROLOT™ WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 26 OF 28

FIGURE 41 HOT/COLD PLUMBING TAPS - SECTION FROM SIDE

HardieWrap™ weather barrier

60mm HardieFire™ insulationPlumbing services

run vertically through 30mm service cavity.

6mm Villaboard™ lining installed, waterproofed

and tiled as per Wet Area Construction Guide

90x45mm additional timber noggin for tap support. Insert nogging prior to HardieFire™ insulation

Continuous 6mm bead of wet area appropriate fire-rated sealant around tap

WARNING: When fixing lining, avoid nailing near pipes or cables as it may cause damage. Refer to Figure 35 for plate and stud penetration details.

HardieZeroLot™ panel

FIGURE 40 HOT/COLD PLUMBING TAPS - SECTION FROM ABOVE

HardieWrap™ weather barrier

Plumbing services run through 30mm service cavity

6mm Villaboard™ lining installed, waterproofed and tiled as per Wet Area Construction Guide

Refer to Figure 35 for drill hole size and location

90x45mm additional timber noggin for tap support. Insert nogging prior to HardieFire™ insulation

Continuous 6mm bead of wet area appropriate fire-rated sealant around tap

WARNING: When fixing lining, avoid nailing near pipes or cables as it may cause damage. Refer to Figure 35 for plate and stud penetration details.

HardieZeroLot™

panel

2207-63_JH_HardieSmart_Zerolot_Design_Guide_2A_PP.indd 26 26/06/2017 10:42 AM

CodeMark Certification

Certificate CM20136

Page 30: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

PAGE 30 OF 32 | HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017HARDIESMARTTM BOUNDARY WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 18 OF 20

Notes

Page 31: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

HARDIESMART™ ZEROLOT™ WALL SYSTEM DESIGN GUIDE OCTOBER 2017 | PAGE 31 OF 32HARDIESMARTTM BOUNDARY WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 19 OF 20HARDIESMARTTM BOUNDARY WALL SYSTEM DESIGN GUIDE APRIL 2017 PAGE 18 OF 20

Notes

Page 32: SYSTEMS - James Hardie Industries · SYSTEMS HardieSmart ™ ZeroLot™ Wall ... INTRODUCTION 3 MINIMUM REQUIREMENTS 3 APPLICATIONS 3 ... the proximity of electrical wiring and …

For information and advice call 13 11 03 | jameshardie.com.au

© 2017 James Hardie Australia Pty Ltd ABN 12 084 635 558 ™ and ® denote a trademark or registered mark owned by James Hardie Technology Limited.

Australia October 2017