2
System layout and performance prediction for a solar-hybrid micro-gas turbine
B Ssebabi, Prof F Dinter and Dr J van der Spuy
Solar Thermal Energy Research Group (STERG), University of Stellenbosch
3
• Background
• Solar-hybrid gas turbine systems in literature
• Application of a turbocharger as a micro-turbine
• Application of a turbocharger as a solar-hybrid MGT
4
• Solar-hybrid power systems combine solar energy and fossil fuel = reliable power with full dispatchability
• Application of MGTs in solar power systems is a relatively new research field
• Past research has mainly focussed on the test and validation of receiver concepts
5
Compressor
Fuel
Combustion chamber
Turbine
𝑊𝑜𝑢𝑡
Solar tower
Solar-hybrid gas turbine system Solar-hybrid Brayton cycle
6
• Include 3 European Commission funded projects; SOLGATE, SOLHYCO and SOLUGAS
• Employed commercial and relatively expensive gas turbines – also complicated in construction
• Gas turbines faced numerous operational challenges and eventually had to be shut down
7
• SOLGATE: Modified an Allison model 250 helicopter engine
• Faults with the oil system cut short the turbine tests
8
• SOLHYCO: Initially adapted the SOLGATE gas turbine to bio-diesel operation
• Modified commercially available 100 kWeTurbec T100 micro-turbine for solar-hybrid cogeneration application
• Faulty oil cooling system cut short the bio-diesel turbine tests
• Output electric power also decreased and unstable control and surges occurred during operation and shutdown
Turbec T100 micro-turbine
9
• Turbochargers are relatively cheap and abundant• Performance and efficiency of modern small
turbochargers has greatly improved• Availability of cheap highly efficient high speed
motor generators• MTT b.v. (Micro Turbine Technology) developed a 3 kW
recuperated micro-turbine for CHP applications based on
turbocharger technology
10
• Combined off-the-shelf turbocharger components with in-house built components
• Improved individual component performance so as to increase net electric output and efficiency
• Final test results showed increase in electric efficiency from 12.2% to 17.2%, at an electric output of 3.4 kWe
Gas generator tests Simple cycle tests Recuperated cycle tests
𝑃𝑒𝑙𝑒𝑐 = 3.25 kWe𝜂𝑡ℎ = 6.34%
𝑁 = 240 000 rpm
𝑃𝑒𝑙𝑒𝑐 = 2.8 kWe𝜂𝑒𝑙𝑒𝑐 = 6.28%
𝑁 = 218 000 rpm
𝑃𝑒𝑙𝑒𝑐 = 2.7 kWe𝜂𝑒𝑙𝑒𝑐 = 12.2%
𝑁 = 240 000 rpm
11
• The use of a turbocharger ensures a simple and modular structure, easy usage and low cost
• Determine design point performance for a simple gas turbine Brayton cycle
Simple micro-gas turbine system
Inputs: 𝑃𝑅𝑐𝑜𝑚𝑝 = 2.5
𝑇03 = 1100 KȠ𝑐𝑜𝑚𝑝 = 75%
Ƞ𝑡𝑢𝑟𝑏 = 68%Ƞ𝑐𝑜𝑚𝑏= 99%∆𝑃𝑏 = 2% comp. deliv. press.
12 3
4
12
Results:
Specific work output = 54.5 kJ/kg Air mass flow required (10 kW plant) = 0.183 kg/sSpecific fuel consumption = 0.345 kg/kWhCycle efficiency = 24%
14
• Select turbocharger from Garrett catalog and input compressor and turbine performance maps
GT2871R Garrett compressor mapDigitised compressor map
15
Work in pipeline:
• Design, build and test solar-hybrid MGT combustor at the Institute of Thermal Turbomachinery and Machinery Laboratory, University of Stuttgart
16
ACKNOWLEDGEMENTS:
CONTACT DETAILS:
visit us: concentrating.sun.ac.za
Solar Thermal Energy Research Group (STERG)Stellenbosch University South Africa
Brian Ssebabi
[email protected]+27 (0)21 808 4016