Page 1: System flowchart Servo-u MR System version 4

System flowchart Servo-u MRSystem version 4.1

Page 2: System flowchart Servo-u MR System version 4

G E T I N G E • S E R V O - U M R2

Contents

Base unit ...............................................................................................3MR conditional accessories ..........................................................3MR safe accessories ........................................................................3Base software .....................................................................................3Country kit ...........................................................................................3O2 cell / O2 sensor ............................................................................ 4Extra expiratory cassette .............................................................. 4Software options .............................................................................. 4NAVA and Edi monitoring ...............................................................5Y sensor ............................................................................................... 6CO2 analyzer ...................................................................................... 6Battery ...................................................................................................7Heliox .....................................................................................................7Gas supply hoses ..............................................................................8Mounting options ..............................................................................8Support arm ........................................................................................8Viral/bacterial filter ......................................................................... 9Heater humidifier ............................................................................. 9Patient breathing system – Heater humidifier ......................10Extra accessories ............................................................................10Connectivity .....................................................................................10

Page 3: System flowchart Servo-u MR System version 4

G E T I N G E • S E R V O - U M R 3

Servo-u MR country kit English/US, DISS connections, North American power cable68 88 788• Including:

– Gas inlet connections.– Mains power inlet cable.– User’s manual.

Country kit

Dark grey line = standard system configuration

Green text = Upgrade of existing ventilators

Blue text = Compatibility note

Base unit For new ventilators: For upgrade of installed ventilators:

Upgrade via E-delivery, Servo-u MR68 88 835• Only personnel trained and autho-

rized by Getinge shall be permitted to install System software and Software options.

• Necessary for E-delivery of software option upgrades via the MCC SW download website https://swdownload.getinge.com

• Including:– User’s manual.

USB memory stick68 80 101

Servo-u MR, system version 4.1

Base software Servo-u68 84 598• Including:• Adult patient category, tidal volume 100-4000 ml.• Pediatric patient category, tidal volume 10-350 ml.• Invasive ventilation modes:

– NAVA.– Pressure Support (PS)/CPAP.– Pressure Control (PC).– Volume Control (VC).– PRVC.– Volume Support (VS).– Bi-Vent/APRV.– SIMV(PC) + PS.– SIMV(VC) + PS.– SIMV(PRVC) + PS.

• Stress Index software.

Base software

Base unit Servo-u MR68 88 800Magnetic field indicator68 87 850Mobile cart, Servo-u MR68 87 962Note! All three article numbersabove must be ordered.• Including:

– User interface.– Patient unit.– Battery module, 2 pcs.– Expiratory cassette, 1 pcs.– Test tube, grey.– Test Lung 190, adult.– Test Lung 191, neonatal.– Installation instructions.

Base software, Country kit andO2 sensor/O2 cell must beordered separately (see below).

MR conditional accessoriesThe following accessories can be used in the MR room:•High pressure hoses for O2 and air.• Gas cylinder restrainer kit.• Heliox Servo adapter kits.The conditions for use of the MR conditional accessories are the same as forthe Servo-u MR in the MR room.

MR safe accessoriesThe following accessories can be used without restrictions in the MR room:• Y piece holder and hook.• Cable holder.• Patient breathing systems for MR, disposable (EVA)• Viral/bacterial filters

= and/or = box for ordered quantity

a⁄o

Page 4: System flowchart Servo-u MR System version 4

G E T I N G E • S E R V O - U M R4

O2 cell / O2 sensorDisposable

O2 cell, new Servo ventilator66 50 118• Disposable.

O2 cell for exchange on installed Servoventilators: Order no 66 40 044

O2 sensor, new Servo ventilator66 70 680• Reusable.

O2 sensor, on-site upgrade:Order no 66 70 600

Reusable

Extra expiratory cassette Expiratory cassette, darkgrey, Servo ventilator66 93 752

One Expiratory cassette is delivered witheach base unit.

Software optionsSoftware Neonatal, Servo-u68 80 514• Tidal Volume 2-50 ml.• Leakage compensation for

invasive ventilation modes.• Neonatal alarm management.• Software Y sensor.

Software NIV, Servo-u68 80 513• NIV PS.• NIV PC.

Software NasalCPAP, Servo-u68 80 515

Software Automode,Servo-u66 93 655• Automode PC <--> PS.• Automode PRVC <--> VS.• Automode VC <--> VS.

Software High Flowtherapy, Servo-u68 85 303

Software ServoCompass, Servo-u68 85 301

Software Transpulmonary pressure, Servo-u68 89 015• To be used together with

Y sensor Module, Servo-u/Servo-n.

Software Open LungTool trends, Servo-u68 87 809

Software Open Lung ToolAuto RM, Servo-u68 89 017• Including

– Software Open Lung Tool trends, Servo-u.

Software Open Lung ToolAuto SRM, Servo-u68 89 019• Including

– Software Open Lung Tool trends, Servo-u.

– Software Open Lung Tool Auto RM, Servo-u.

Software Alarm output,Servo-u68 80 516

Requires Y sensor module(66 93 662), (see below)

Page 5: System flowchart Servo-u MR System version 4

G E T I N G E • S E R V O - U M R 5

Guide wire for Edicatheter, 8 Fr, adult125 cm, 5 pcs/pkg66 71 292

Guide wire for Edicatheter, 8 Fr,pediatric, 100 cm,5 pcs/pkg66 71 272

Guide wire for Edicatheter, 6 Fr,neonatal, 49 + 50cm, 5 pcs/pkg66 71 270

6 plug-in slots for modules are available.• Each battery module occupies 1 slot (2 battery modules are delivered with each base unit).• 1 slot is occupied if the Edi module is selected.• 1 slot is occupied if the Y sensor module is selected.• 1 slot is occupied if the CO2 analyzer module is selected.NAVA and Edi monitoring

Edi module, Servo ventilator60 Hz 66 72 332• Including:

– Edi module cable, 2 m, with Edi module test plug.

Software NIV NAVA,Servo-u68 80 517

Edi catheter

EN Fit connector Funnel connector

Adult

Adult

Pediatric

Pediatric

Neonatal

Neonatal

Edi catheter, ENFit,16 Fr/125 cm,5 pcs/pkg68 83 904• Disposable.• PHT free.

Edi catheter, ENFit,8 Fr/125 cm,5 pcs/pkg68 83 902• Disposable.• PHT free.

Edi catheter, ENFit,12 Fr/125 cm,5 pcs/pkg68 83 903• Disposable.• PHT free.

Edi catheter, ENFit,8 Fr/100 cm,5 pcs/pkg68 83 901• Disposable.• PHT free.

Edi catheter, ENFit,8 Fr/50 cm,5 pcs/pkg68 83 900• Disposable.• PHT free.

Edi catheter, ENFit,6 Fr/49-50 cm,5 pcs/pkg49 cm 68 83 898

50 cm 68 83 899• Disposable.• PHT free.

Guide wire for Edicatheter, 8 Fr, adult125 cm, 5 pcs/pkg66 71 292

Guide wire for Edicatheter, 8 Fr,pediatric, 100 cm,5 pcs/pkg66 71 272

Guide wire for Edicatheter, 6 Fr,neonatal, 49 + 50cm, 5 pcs/pkg66 71 270

Edi catheter, 16 Fr,adult, 125 cm,5 pcs/pkg66 85 790• Disposable.• PHT free.

Edi catheter, 8 Fr,adult, 125 cm,5 pcs/pkg66 85 782• Disposable.• PHT free.

Edi catheter, 12 Fr,pediatric, 125 cm,5 pcs/pkg66 85 787• Disposable.• PHT free.

Edi catheter, 8 Fr,pediatric, 100 cm,5 pcs/pkg66 85 780• Disposable.• PHT free.

Edi catheter, 6 Fr,neonatal, 5 pcs/pkg49 cm 66 85 775

50 cm 66 85 777• Disposable.• PHT free.

The Edi module occupies one plug-in slot.

Page 6: System flowchart Servo-u MR System version 4

G E T I N G E • S E R V O - U M R6

Y sensor

CO2 analyzer

The Y sensor module occupies one plug-in slot.

CO2 analyzer moduleCapnostat 5, Servoventilators68 87 050

The CO2 analyzer module occupies one plug-in slot.

Capnostat 5 mainstreamCO2 sensor68 82 078• With 2.8 m cable.

Neonatal and pediatric

Software Y sensor,Servo-u68 80 518• Included in Software

Neonatal, Servo-u.

Y sensor module,Servo-u/Servo-n66 93 662• Including:

– Sensor cable.

Y sensor pressureline, 1.8 m, disposable,10 pcs/pkg66 93 672

Y-piece 10 mm angled,sampling port, 5 pcs/pkg68 80 253• Disposable.

Required if Y sensor is used togetherwith a CO2 airway adapter

CO2 /Y sensoradapter, 10 pcs/pkg68 80 104• Disposable.

Disposable

Y sensor neonatal,disposable,5 pcs/pkg66 93 667

Software CO2 analyzer, Servo-u66 93 680

Page 7: System flowchart Servo-u MR System version 4

G E T I N G E • S E R V O - U M R 7

a⁄o

Note! Heliox is not compatible withO2 sensor (only with O2 cell)

DISS connections

Software Heliox,Servo-u68 89 886

Hose Heliox, DISS, 5 m66 75 592• Transparent with

green/brown color marking.

Neonatal

Disposable

Adult

CO2 airway adapter,neonatal (disposable),10 pcs/pkg66 84 610

CO2airway adapter,adult (disposable),10 pcs/pkg66 84 612

Battery module,Servo ventilator64 87 180

Each battery module occupies oneplug-in slot.Two battery modules are delivered witheach base unit.

Battery

Heliox

Heliox Servo adapter kit, DISS 68 89 487 • Including:

– Heliox adapter.– Air adapter.– Inlet connector for ventilator, including O-ring.– Heliox adapter holder (two versions).– O2 cell locking catch.– Air/HeO2 sticker.– Installation instructions.

Page 8: System flowchart Servo-u MR System version 4

G E T I N G E • S E R V O - U M R8

DISS connections, US Color markings

Hose, O2, DISSfemale/female(green), 4.5 m64 19 944

Hose, Air, DISSfemale/female(yellow)1.5 m 66 70 300

4.5 m 64 81 753

a⁄o

Clamp, rail 10 x 25 mm60 38 801

Clamp, 1 slot93 58 193

a⁄o

Y piece holder and hook,Servo ventilator handle68 80 548• Mounts on the handle.

Cable holder, Servoventilator handle66 93 747• Mounts on the handle.

Support Arm 178 for Servo-u/Servo-n66 93 715• With patient tube holder. For mount at a rail 10 x 25 mm.• Including:

– Support clamp.

Gas supply hoses

Mounting options

Support arm

Gas cylinder restrainer kit, US, Servo-u/Servo-n68 85 179• Max 2 x 4.5 L cylinders.• Mounts on Mobile cart

Servo-u/Servo-n.

Page 9: System flowchart Servo-u MR System version 4

G E T I N G E • S E R V O - U M R 9

Viral/bacterial filterServo Guard viral /bacterial filter, 50 pcs/pkg65 95 487

Servo Duo Guardviral/bacterial filter,60 pcs/pkg66 71 775

Expiratory heater,Servo Duo Guard66 93 732

Thermoshell, Expiratory cassetteServo ventilator, 5 pcs/pkg68 80 848• To be used when dual heated

circuits are used.

Fisher & Paykel Humidifier MR 850115 V, English/Spanish/French text,North Am. right angle mains power plug 65 45 193

Alt. 1: Active humidification (Heater humidifier)

Mount at Mobile cart or rail 10 x 25 mm

Waterbag/IV polefor humidifier holder66 93 722• Max load 1.5 kg.

Fisher & Paykel cable,temperature and flowprobe MR 850, 1.5 m65 95 255

Humidifier Holder Servo-u/Servo-n66 93 735• Including:

– Clamp for rail 10 x 25, Humidifier holder.• For mount at a rail 10 x 25 mm, or slot mount.

Disposable for MR

Breathing system for HME,(MR), disposable 15 mm(3.0 m) 20 pcs/pkg66 92 172• Y-piece, angled connector

and patient tubes can be detached.

Breathing system for HME(MR), disposable 22 mm(3.0 m) 20 pcs/pkg66 92 177• Y-piece, angled connector and

patient tubes can be detached.

22 mm patient tubes 15 mm patient tubes 10 mm patient tubes

Breathing system for HME,(MR), disposable 10 mm(3.0 m) 20 pcs/pkg66 92 175• Y-piece, angled connector and

patient tubes can be detached.

Alt. 2: No humidifierHeater humidifier

Page 10: System flowchart Servo-u MR System version 4

G E T I N G E • S E R V O - U M R10

Extra accessories

Connectivity

a⁄oa⁄o

a⁄o

Thermoshell, Expiratory cassetteServo ventilator, 5 pcs/pkg68 80 848• To be used when dual heated

circuits are used.

Test tube, grey64 87 941

One Test tube is delivered with eachbase unit.

Test Lung 190, adult60 06 832

One Test Lung 190 adult is deliveredwith each base unit.

Test Lung 191,neonatal63 01 720

USB memory stick68 80 101

Data cable Servoventilator to PC, 2.4 m65 23 570• 9 pin female PC plug.

One Test Lung 191 neonatal is delivered with each base unit.

Patient breathing system – Heater humidifier

Disposable

Single heated Dual heated High flow therapy

Neonatal/Pediatric Adult Adult

Fisher & Paykel cablefor disposable singleheated circuit65 95 206

Fisher & Paykel cablefor disposable dualheated circuit65 95 214

Fisher & Paykel tube set –Disposable:RT131 (Flows >4 LPM)RT130 (Flows <4 LPM)• Local delivery.

Fisher & Paykel tube set –Disposable:RT380• Local delivery.

Fisher & Paykel tube set –Disposable:RT265 (Flows >4 LPM)RT266 (Flows <4 LPM)• Local delivery.

Fisher & Paykel tube set –Disposable:RT202• Local delivery.

Fisher & Paykel tube set Disposable:RT331• Local delivery.

Fisher & Paykel tube set –Disposable:RT205• Local delivery.

Neonatal/PediatricAdult Neonatal/Pediatric

Alt. 1: Active humidification (Heater humidifier)

Fisher & Paykel cablefor disposable singleheated circuit65 95 206

Alt. 2: No humidifier

Page 11: System flowchart Servo-u MR System version 4

G E T I N G E • S E R V O - U M R 11

Notes

Page 12: System flowchart Servo-u MR System version 4

CAUTION: Federal (US) law restricts this device to sale by or on the order of a physician. Refer to Instructions for Use for current indications, warnings, contraindications, and precautions.

Getinge is a global provider of innovative solutions for operating rooms, intensive care units, sterilization departments and for life science companies and institutions. Based on our firsthand experience and close partnerships with clinical experts, healthcare professionals and medtech specialists, we are improving the everyday life for people, today and tomorrow.

Manufacturer · Maquet Critical Care AB · Röntgenvägen 2 · SE-171 54 Solna · Sweden · +46 (0)10 335 73 00Sales Office · Getinge · 1 Geoffrey Way · Wayne, NJ 07470 · USA

www.getinge.com © M

aque

t Crit

ical

Car

e A

B 20

21 · G

etin

ge, S

ervo

-u, A

utom

ode,

Ope

n Lu

ng T

ool,

Serv

o C

ompa

ss, N

AVA

, Ser

vo G

uard

are

regi

ster

ed tr

adem

arks

of G

etin

ge A

B, it

s su

bsid

iarie

s, o

r affi

liate

s in

the

Uni

ted

Stat

es o

r oth

er c

ount

ries

· All

right

s re

serv

ed ·

Subj

ect t

o m

odifi

cati

ons

· Ord

er N

o. 6

8 91

291

Rev

01 ·

MC

V001

0750

1 REV

A · S

ervo

-u M

R, S

yste

m v

ersi

on 4

.1 –

Syst

em fl

owch

art ·

202

1-05