1
HVAC SYSTEM CONTROL PANEL HVAC SYSTEM AHU - GALLEY CONTROL PANEL XXX-EC-XXX BLOWER FAN - A XXX-DE-XXX THREE WAY VALVE - A XXX-MV-XXX AHU - A GALLEY STATUS / ALARM SIGNAL (DRY CONTACT) NORMAL POWER SUPPLY (XC x XX Sq-mm) 9 +] (XXX-EN-XXX) XXX-XS-XXX 220VAC SHUTDOWN SIGNAL (DE-ENERGIZED TO SHUTDOWN) F & G MSB PCS / ICSS PANEL FEATURE * 440VAC NORMAL INCOMING POWER INDICATOR * AMMETER * BLOWER FAN - A RUN STATUS INDICATOR * BLOWER FAN - A TRIP STATUS INDICATOR * BLOWER FAN - A STOP STATUS INDICATOR * START PUSH BUTTON - A * F&G SHUTDOWN INDICATOR * E - STOP PUSH BUTTON GALLEY COMPARTMENT XXX-TS-XXX TEMPERATURE TRANSMITTER - 1A * DUTY / STANDBY SELECTOR SWITCH * AUTO / MANUAL SELECTOR SWITCH * TEMPERATURE CONTROLLER * STOP PUSH BUTTON - A ELECTRIC HEATER - A XXX-FE-XXX XXX-RS-XXX TEMPERATURE SENSOR - 2 GALLEY COMPARTMENT TEMPERATURE SENSOR - 1 FRESH AIR XXX-TS-XXX BLOWER FAN PRESSURE DIFFERENTIAL SWITCH - A * BLOWER FAN - B RUN STATUS INDICATOR * BLOWER FAN - B TRIP STATUS INDICATOR * BLOWER FAN - B STOP STATUS INDICATOR * START PUSH BUTTON - B * STOP PUSH BUTTON - B * LAMP TEST PUSH BUTTON 24VAC POWER SUPPLY 4-20mA CONTROL SIGNAL 9 +] POWER SUPPLY 4-20mA SIGNAL SENSOR SENSOR 4-20mA CONTROL DEVICE CONTROL DEVICE SAFETY DEVICE CONTROL SIGNAL 24VAC POWER SUPPLY XXX-PDS-XXX BLOWER FAN - B XXX-DE-XXX THREE WAY VALVE - B XXX-MV-XXX AHU - B GALLEY ELECTRIC HEATER - B XXX-FE-XXX BLOWER FAN PRESSURE DIFFERENTIAL SWITCH - B XXX-PDS-XXX * HEATER - A/B ON STATUS INDICATOR * HEATER - A/B TRIP STATUS INDICATOR SAFETY DEVICE XXX-EC-XXX F&G DAMPER CONTROL PANEL HVAC SYSTEM INTERLOCK GALLEY COMPARTMENT XXX-TS-XXX TEMPERATURE TRANSMITTER - 1B 4-20mA SIGNAL 9 +] POWER SUPPLY 9 +] POWER SUPPLY 9 +] POWER SUPPLY * LOW AIR FLOW ALARM INDICATOR * LOW AIR FLOW ALARM RESET PUSH BUTTON * LOW AIR FLOW ALARM INDICATOR * LOW AIR FLOW ALARM RESET PUSH BUTTON * HOUR RUN METER * HOUR RUN METER (HEATING) MSB, FGS & PCS / ICSS HVAC SYSTEM EQUIPMENT / COMPONENT Golar LNG

System Block Diagram_hvac System_3

Embed Size (px)

Citation preview

  • HVAC SYSTEM

    CONTROL PANEL

    HVAC SYSTEM

    AHU - GALLEY

    CONTROL PANEL

    XXX-EC-XXXBLOWER FAN - AXXX-DE-XXX

    THREE WAY VALVE - AXXX-MV-XXX

    AHU - AGALLEY

    STATUS / ALARM SIGNAL(DRY CONTACT)

    NORMAL POWER SUPPLY

    (XC x XX Sq-mm)????????????????

    (XXX-EN-XXX)

    XXX-XS-XXX220VAC SHUTDOWN SIGNAL

    (DE-ENERGIZED TOSHUTDOWN)

    F & G

    MSB

    PCS / ICSS

    PANEL FEATURE

    * 440VAC NORMAL INCOMING POWER INDICATOR* AMMETER

    * BLOWER FAN - A RUN STATUS INDICATOR* BLOWER FAN - A TRIP STATUS INDICATOR* BLOWER FAN - A STOP STATUS INDICATOR

    * START PUSH BUTTON - A

    * F&G SHUTDOWN INDICATOR* E - STOP PUSH BUTTON

    GALLEY COMPARTMENTXXX-TS-XXX

    TEMPERATURE TRANSMITTER - 1A* DUTY / STANDBY SELECTOR SWITCH* AUTO / MANUAL SELECTOR SWITCH

    * TEMPERATURE CONTROLLER

    * STOP PUSH BUTTON - A

    ELECTRIC HEATER - AXXX-FE-XXX

    XXX-RS-XXX

    TEMPERATURE SENSOR - 2GALLEY COMPARTMENT

    TEMPERATURE SENSOR - 1FRESH AIRXXX-TS-XXX

    BLOWER FAN

    PRESSURE DIFFERENTIALSWITCH - A

    * BLOWER FAN - B RUN STATUS INDICATOR* BLOWER FAN - B TRIP STATUS INDICATOR* BLOWER FAN - B STOP STATUS INDICATOR

    * START PUSH BUTTON - B* STOP PUSH BUTTON - B

    * LAMP TEST PUSH BUTTON

    24VAC POWER SUPPLY

    4-20mA CONTROL SIGNAL

    ???????????????? POWER SUPPLY

    4-20mA SIGNAL

    SENSOR

    SENSOR

    4-20mA

    CONTROL DEVICE

    CONTROL DEVICE

    SAFETY DEVICE

    CONTROL SIGNAL

    24VAC POWER SUPPLY

    XXX-PDS-XXX

    BLOWER FAN - BXXX-DE-XXX

    THREE WAY VALVE - BXXX-MV-XXX

    AHU - BGALLEY

    ELECTRIC HEATER - BXXX-FE-XXX

    BLOWER FAN

    PRESSURE DIFFERENTIALSWITCH - B

    XXX-PDS-XXX

    * HEATER - A/B ON STATUS INDICATOR* HEATER - A/B TRIP STATUS INDICATOR

    SAFETY DEVICE

    XXX-EC-XXX

    F&G DAMPER CONTROL PANELHVAC SYSTEM

    INTERLOCK

    GALLEY COMPARTMENTXXX-TS-XXX

    TEMPERATURE TRANSMITTER - 1B 4-20mA SIGNAL

    ???????????????? POWER SUPPLY

    ???????????????? POWER SUPPLY

    ???????????????? POWER SUPPLY

    * LOW AIR FLOW ALARM INDICATOR

    * LOW AIR FLOW ALARM RESET PUSH BUTTON

    * LOW AIR FLOW ALARM INDICATOR

    * LOW AIR FLOW ALARM RESET PUSH BUTTON

    * HOUR RUN METER

    * HOUR RUN METER

    (HEATING)

    MSB, FGS & PCS / ICSSHVAC SYSTEM EQUIPMENT / COMPONENT

    Golar LNG