Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
Sync™ Single-Leg/Double-Leg Base Units
Page 1 of 7939549945 Rev E
If you have a problem, question, or request, callyour local dealer, or Steelcase Line 1 at888.STEELCASE (888.783.3522)for immediate action by people who want to help you.
(Outside the U.S.A., Canada, Mexico, Puerto Rico, and the U.S. Virgin Islands, call: 1.616.247.2500)Or visit our website: www.steelcase.com© 2014 Steelcase Inc. Grand Rapids, MI 49501 U.S.A.
Printed in U.S.A.
®
HEALTH
This equipment has been tested and found to comply with the limits for a class B digital device pursuantto Part 15 for FCC rules. These limits are designed to provide reasonable protection against harmfulinterference in a residential installation. This equipment generates, uses and can radiate radio frequencyenergy and, if not installed and used in accordance with the instructions, may cause harmful interferenceto radio communications. However, there is no guarantee that interference will not occur in a particularinstallation. If this equipment does cause harmful interference to radio or television reception, which can bedetermined by turning the equipment off and on, the user is encouraged to try to correct the interference byone or more of the following measures: • Reorient or relocate the receiving antenna. • Increase theseparation between the equipment and receiver. • Connect the equipment into an outlet or a circuit differentfrom that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technicianfor help.
This class B digital apparatus complies with Canadian ICES-003.Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada
The power socket/outlet shall be installed near the equipment and shall be easily accessible.
SAVE THESE INSTRUCTIONS
OPERATING INSTRUCTIONS - Please refer to the attached Installation Instructions and the provided User Guide.
USER-MAINTENANCE INSTRUCTIONS -
- DANGER Do not modify the plug provided with the product - if it will not fit the outlet, have a proper outletinstalled by a qualified electrician.
The receptacle power block is equipped with a circuit breaker that will shutoff power in an overload condition. Press to reset the circuit breaker to restore power.SERVICING OF DOUBLE-INSULATED PRODUCTS - In a double-insulated product, two systems of insulation are providedinstead of grounding. No grounding means is provided on a double-insulated product, nor is a means for grounding to be addedto the product. Servicing a double-insulated product requires extreme care and knowledge of the system, and is to be done onlyby qualifiedservice personnel. Replacement parts for a double-insulated product must be identical to the parts they replace. Adouble-insulated product is marked with the words “DOUBLE INSULATION” or “DOUBLE INSULATED.” The symbol(square within a square) is also able to be marked on the product.
IMPORTANT SAFETY INSTRUCTIONSWhen using an electrical furnishing, basic precautions should always be followed, including the following:Read all instructions before using (this furnishing).
- To reduce the risk of electric shock:DANGER1. Always unplug this furnishing from the electrical outlet before cleaning.2. Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled persons.3. Use this table only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer.4. Never operate this table if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. If the cord is damaged have it replaced by a Steelcase dealer.5. Keep the cord away from heated surfaces.6. Never drop or insert any object into any opening.7. Do not use outdoors.8. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.9. To disconnect, remove plug from outlet.10. Do not use this table to support televisions.11. Each surface intended to support a load shall have a corresponding statement in the use instructions specifying the maximum intended load for that surface.12. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.13. Children should be supervised to ensure that they do not play with the appliance.
WARNING
®
WARNINGPinch points. Keep Clear.Risk of Serious Injury.If not used as intended, movingworksurfaces can pinch andcause injury or property damage.Always follow these instructions:
Keep height-adjustment range free fromobstructions above and below the worksurface.Plan for a minimum 1” gap against a wall or panel.Plan for a minimum 1” gap to adjacent furniture.
1.
2.3.
This powered, adjustable height desk appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
WARNING RISK OF SERIOUS INJURY:
Page 2 of 7939549945 Rev E
2
1
3
1. For height adjustable units, measure any protrusion from back or side walls that exists below the maximum adjusted height of worksurface.
2. Make sure resulting width of installation niche from back wall corner to corner, after subtracting any side wall protrusions, falls within the following ranges for the respective nominal width unit:• 60" nominal - 54" to 66"• 72" nominal - 66" to 78"(Omit this step for Single Leg)
Page 3 of 7939549945 Rev E
MARK HOLELOCATIONS
MARK HOLELOCATIONS
4
FOR 135 DEGREE WORKSURFACE LOCATIONS[943102529SR]
FOR 90 DEGREE WORKSURFACE LOCATIONS[943102528SR]
3. Use (customer service part number 943102528SR for 90° legs and 943102529SR for 135° legs) template to mark three (3) hole locations for floor anchors.
4a. Offset "side wall" edge of template from side wall by depth of any protrusions (window frame, sill, etc.) that exist between 25" - 50" above floor.
4b. Offset "back wall" edge of template by a distance 1" less than depth of any protrusions (window frame, sill, etc.) that exist between 25" - 50" above floor.
WIDTH OF THEINSTALLATION NICHE
BACK WALLPROTRUSION
SIDE WALLPROTRUSIONDEPTH
DEPTH MINUS 1"
SIDE WALLPROTRUSIONDEPTH
BACK WALLPROTRUSION
DEPTH MINUS 1"
®
HEALTH
6
FLOORANCHOR
NOTE: Consult building's Engineer of Record to specify correct fasteners for attachment to building and to ensure that building has adequate structure. There are three (3) holes provided per mounting plate (.600” diameter) for floor anchor clearance. Product was tested while mounting to 3/8” diameter floor anchors in 4” concrete.
5. Install floor anchors per fastener manufacturer's specifications. Leave 2-1/4" of exposed stud for leveling purposes.
6. Thread a nut, then a washer on each floor anchor as shown.
7. Loosen nuts on the upper and lower support rails to allow the unit to adjust to the floor anchor position.(Omit this step for Single Leg)
8. Set unit on floor anchors. Plumb and level base unit using nuts and washers.
9. Plumb each leg making sure top support rail is also level. Use nuts to make any necessary adjustments.
10. Secure unit with a washer, lock washer and nut, as shown, to secure plate.
11. Tighten nuts on upper and lower support rails that were loosened in step 7.(Omit this step for Single Leg)
12. Check legs and top support rail for plumb and level.
Page 4 of 7939549945 Rev E
CROSS SECTIONOF FINAL ORDER FLOOR ANCHOR
NUTLOCK WASHER
WASHERPLATE
NUT
WASHER
MFG. RECOMMENDEDNUT / WASHER
FLOOR ANCHOR
NUT
LOCK WASHER
WASHER
10
7
LOOSEN LOWER SUPPORT RAIL HERE
LOOSEN UPPER SUPPORT RAIL HERE
®
HEALTH
13. Install CPU's using straps provided.
14. Route all power and data cables necessary. For adjustable height legs, reference Wire Management assembly direction 939549946.
Page 5 of 7939549945 Rev E
13
®
HEALTH
Page 6 of 7939549945 Rev E
15. For each foot, a foot cover needs to be installed. Install RH foot cover so it encompasses leg column, as shown (15a). Install LH foot cover next to RH foot cover by sliding downward and engaging RH foot cover (15b) until it is fully secured into place (15c).
LEGCOLUMN
RH FOOTCOVER
RH FOOTCOVER
15a
15b
15c
LH FOOTCOVER
®
HEALTH
16. Install tile by placing it flat against stretcher and sliding it down, making sure top and bottom hooks engage simultaneously.
Page 7 of 7939549945 Rev E
17
TOP CAP
16
TILE
17. Install top cap by aligning tabs on bottom with slots in top rail of tile. Lower top cap until it rests on top edge of tile. Pull out extensions on both ends of top cap until they engage with molded caps on either end of stretcher.
®
HEALTH