SYNC2000 Quick Start Guide and Warranty Document
Version 1.0, February 2011
SYNC2000 is KEMA certified for 61850 Server and is IEC 61850-3 compliant mid-sized field device with up to six Serial channels, two Ethernet channels, Optional modem card and IO board for applications like substation protocol converters, data loggers, low end data concentration, multi-protocol mapping, industrial complex meter gateway, building automation with all major open standards as well the select proprietary protocols support.
i. SYNC 2000 S6R1 device ii. Kalki CD containing SYNC User Manuals, Protocol User Manual, Easy
Connect Software. iii. Quick start guide (this document)
There is a POWER LED on the top left corner of the front side, which will be in red when the power is up.
DIN-Rail mounting for SYNC2000 S6R1 - A aluminum DIN-Rail attachment plate is included in the package. To attach the plate to the SYNC 2000 S6R1, situate the wider end first into the rail, and then push the stiff metal spring end into the rail, so that the DIN-rail attachment will snap into the place. The steps involved in mounting SYNC 2000 S6R1 are shown below:
To detach the plate, follow step 2 and then step1 as given above.
� Power Connector
24V DC Input supply needs to be provided to the power connectors (combicon) through the DC input connector, present at the top side of SYNC2000 S6R1. The Red power LED will glow indicating the unit is powered up properly.
� Grounding
The ground is provided on the enclosure itself and there is no requirement of special grounding connection as connection is established through the metallic DIN rails
� Ethernet port
LAN 1 port is RJ45 connector for 10/100 Mbps Ethernet ports. The table below gives the signal details for the corresponding 8 pin RJ45 connector. The figure shows the diagrammatic representation of the Ethernet ports.
8 Pin Signal Name
1 TX+ (Transmit +)
2 TX- (Transmit -)
3 RX+ (Receive +)
4 Not Connected
5 Not Connected
6 RX- (Receive -)
7 Not Connected
8 Not Connected
� Serial ports
SYNC 2000 S6R1 has six serial ports (S1,S2,S3,S4,S5,S6) and one console / debug port (CONSOLE), all of which being RJ45 connections. Ports S1, S2, S3 and S4 have both RS232 and RS485 which supports only RS232. There are four externally accessible DIP switches available for switching between RS232 and RS485 on S1-S4 ports. The default setting on these switches is the RS232 mode and t he user needs to change the DIP switch to ON position for changing to RS485.
� Console Port
The console port is also an RJ45 RS-232 port. It can be connected to a V90 or GPRS modem via PPP. The pin definitions are same as the Serial ports.
� Reset Button
Press the ‘Reset’ button on the front panel continuously for at least 5 seconds to load the factory default configuration. After the factory default configuration has been loaded, the system will reboot automatically. The Ready LED will blink for the first 5 seconds, and then maintain a steady glow once the system has rebooted.
EASYCONNECT The gateway comes with an EasyConnect Configuration and Diagnostic's utility.These tools are easy to use and offer access to the gateway configuration, firmware up gradation, diagnostics etc. For further details on EasyConnect software, send a email query to sales. Email: [email protected]
SCAN: The SCAN command will help the user to find out the IP address of the gateway from the network
The default IP Address of the gateway is set as “192.168.0.121”. As shown below, information such as Model Name, Interface Name, IP address, Net mask, MAC address, Product Key etc, are displayed in the “SCAN” window.
8 Pin plug Signal Name (RS232) Signal Name
1 DSR - Data Set Ready --
2 DCD - Data Carrier Detect --
3 DTR - Data Terminal Ready --
4 GND - Signal Ground GND - Signal Ground
5 RxD - Receive Data --
6 TxD - Transmit Data Data +
7 CTS - Clear to Send --
8 RTS - Request to Send Data -
DIN-RAIL MOUNTING
HARDWARE CONFIGURATION
SOFTWARE CONFIGURATION
OVERVIEW
PACKAGE CHECKLIST
SYNC2000-S6R1
LED INDICATORS
CONFIGURING GATEWAY USING EASYCONNECT
Note: Check if the IP Address of the gateway is accessible to the PC where EasyConnect is installed via a network or Ethernet Cross cable. Using EasyConnect user can change the gateway IP, Upload/Download gateway configuration, Update the firmware etc.
To change the Gateway IP:
1. Open EasyConnect
2. Click on IP Configuration\
3. In LAN Settings window, from Device drop-down, select Other Device. Select the appropriate model name(ex:SYNC2000S6R1).In IP address text box, enter the appropriate IP address
According to the model, the number of interfaces will be changed. Enter valid IP addresses, Subnet Mask, Default Gateway and Default gateway Interface for each interface. Click OK to update the changes. The converter will be automatically get restarted.
Operating Temperature : -20 to 70 °C (-4 to 158 °F)
Storage Temperature : -20 to 80 °C (-4 to 176 °F)
Relative Humidity : 5% – 95% RH non condensing
Ethernet Isolation : 1500VAC min per IEEE802.3/ANSI X3.263
SYNC 1000 S2R1 : Similar to SYNC2000 but offers advanced
M2M capabilities and at lower price point.
SYNC 3000 S4R2 / S8R2 : High end field device for large scale protocol
conversion / concentration, with 2 Ethernet
ports, as well as additional processing power,
RAM and storage capabilities.
SYNC 3000 S12R6 : Ruggedized high-end data concentrator with
12 Serial and 6 Ethernet ports.
SYNC 4000 : High end server (control centre level) that can
act as a Front End Processor, Super Phasor
Data Concentrator or an ICCP Bridge
Kalki Communication Technologies Limited is an ISO 9001:2008 certified company based in Bangalore, India. Kalki Communication Technologies Limited was found in 1998 with the vision of becoming the leading provider of standards-based, control, communication and computing solutions to OEMs, system integrators and end-users in the energy industry. Continuous innovation through research and development is at the core of Kalkitech’s corporate philosophy. Over the years, Kalkitech has become the preferred partner for a wide base of multinational clients, known for high quality engineering, automation and communication products, solutions and services. Today, Kalkitech’s solutions are successfully deployed in over 50 countries in 4 continents, across the full spectrum of the energy value chain.
Kalkitech is committed to provide state-of-the-art solutions to the industry, combining the latest advances in power systems engineering and information technology, based on international standards. We help customers monitor, control, visualize, integrate and optimize their enterprise operations in real time.
Kalkitech also offers designing, consulting, engineering analysis and optimization, automation engineering, communication protocol solutions and application software development.
• Email support on Configuration and engineering support would be provided at free of cost. Contact support at [email protected]
• For details on pricing for configuration and engineering support over phone and webex, please contact:
Email: [email protected] Phone: +91-80 4052 7906
• Refer the package CD for SYNC user manuals. The user manuals can also be downloaded from literature section of our website at: http://www.kalkitech.com/literature/collateral/user_manuals/
Website: www.kalkitech.com
Copyright© Kalki Communication Technologies Ltd. All Rights Reserved
First Edition February, 2011
Product specifications and descriptions in this document subject to change
without prior notice.
ENVIRONMENTAL SPECIFICATION
RELATED PRODUCTS
PRODUCT WARRANTY STATEMENT
STANDARD WARRANTY
Kalki Communication Technologies Ltd., (KALKITECH) warrants this product to be free from manufacturing defects in materials and workmanship starting from the date of invoicing.
KALKITECH will replace any product found to be defective within first 12 months of purchase provided said product was properly installed and used. Warranty more than 12 months which was accepted by KALKITECH will be Addendum to this period and will be treated as standard warrant period as applicable. Defects, malfunctions, or failures of the warranted product caused by damage resulting from acts of God (such as floods, fire, etc.,), environmental and atmospheric disturbances, other external forces such as power line disturbances, plugging the board in under power, or incorrect cabling, and damage caused by misuse, abuse, and unauthorized alteration or repair, are not warranted.
Customers must obtain a return merchandise authorization (RMA) number prior to returning a defective product to KALKITECH for service. The customer agrees to insure the product or assume the risk of loss or damage during transit and to use the original shipping container or equivalent. Repaired or replaced products are warranted for ninety (90) days from the date of repair or replacement, or for the remainder of the original product's warranty period, whichever is longer.
LIMITATION OF LIABILITY
The provisions of the warranty are in the lieu of any other warranty, whether expressed are implied, or written or oral. KALKITECH's liability arising out of the manufacture, sale, or supplying of the product and it's use, whether based on the warranty, contract, negligence, product liability, or otherwise, shall not exceed the original cost of the product. In no event shall KALKITECH be liable for unintended or consequential damages, including but not limited to, loss of profits or damages arising out of the manufacture, sale, or supplying of the product.
Warranty Annexure
Warranty Type : □ Standard + □ Addendum: ______________ Months
Product : _: _: _: _______________________________
Quantity : _: _: _: _______________________________
Product Serial No: ___________________________________
Date of Invoice : : : : ________________________________
QAQAQAQA
KALKITECH FZE Hamariyah Free Trade Zone, Sharjah, UAE Telephone: +971-6-5626856 Fax: +971-6-5626852 Email: [email protected]
KALKI Communication Technologies Ltd #147, 5th Main Road, HSR Layout Sector 7, Bangalore 560102, INDIA Telephone: +91-80-4052 7900 Fax: +91-80-2572 5473 Email: [email protected]
KALKITECH Inc. 9900 Westpark Dr, Suite 283, Houston, TX, 77063, USA Telephone: +1-832-922-8910 Fax: +1-313-557-4640 Email: [email protected]
KALKI Communication Technologies Ltd 1/153B Puthuvankunnu, Chowara PO, Cochin Telephone: +91-484-2605 018 Email: [email protected]