7
375 WEST 200 SOUTH SALT LAKE CITY, UT 84101 801.521.860 0 801.521.7913 P F www.gsbsarchitects.c om OWNER PROJECT NO.: GSBS PROJECT NO.: ISSUED DATE: REVISIONS : GSB ARCHITEC PLSPR2017002 72 Contsruction Ducuments 06/02/2017 2015.122.00 ES001 SHEET INDEX, ABBREVIATIONS, AND GENERAL NOTES City of South Jordan Highland Park Daybreak Village 8 South Jordan, UT 10996 S. Redwood Road South Jordan, UT 84095 ELECTRICAL SHEET INDEX ES001 SHEET INDEX, ABBREVIATIONS, AND GENERAL NOTES ES101 SITE ELECTRICAL PLAN ES102 SITE ELECTRICAL PLAN - PHASE 1 ES103 SITE ELECTRICAL PLAN - PHASE 2 ES201 PHASE 1 ENLARGED ELECTRICAL PLAN - CONCESSIONS AND RESTROOM ES202 PHASE 1 ENLARGED ELECTRICAL PLAN - PAVILION AND STORAGE SHED ES203 PHASE 2 ENLARGED ELECTRICAL PLAN - PAVILION AND RESTROOM ES204 SITE SPORTS FIELD PHOTOMETRICS ES205 MUSCO PHOTOMETRICS ES501 SITE ELECTRICAL DETAILS ES502 SITE ELECTRICAL DETAILS ES601 ONE-LINE DIAGRAM ES602 PANEL SCHEDULES ES603 EQUIPMENT SCHEDULE ES701 TYPICAL MOUNTING HEIGHT DETAILS GENERAL ELECTRICAL NOTES 3. EXPOSED STRUCTURE AREAS (EXCLUDING MECHANICAL, ELECTRICAL, AND COMMUNICATION SPACES): INSTALL RACEWAYS BETWEEN DECK AND STRUCTURE WHEREVER POSSIBLE IN EXPOSED STRUCTURE CEILING AREAS. ROUTE RACEWAYS IN CONCEALED AREAS WHEREVER POSSIBLE. REFER ALL CONDITIONS WHERE RACEWAYS MUST BE INSTALLED WHICH CANNOT COMPLY WITH THESE REQUIREMENTS TO THE ARCHITECT. 4. SUBMITTALS: PROVIDE ORIGINAL ELECTRONIC PDF FORMAT, BOUND, BOOKMARKED (EACH SECTION AND PRODUCT), AND HIGHLIGHTED. JOB NAME AND SUBCONTRACTOR SHALL BE ON THE FRONT COVER. PREPARE INDEX OF EQUIPMENT SUBMITTED IN EACH TAB. 5. REFLECTED CEILING PLANS: COORDINATE THE LOCATION OF LIGHT FIXTURES WITH THE ARCHITECTURAL REFLECTED CEILING PLANS. REFER ALL DISCREPANCIES TO THE ARCHITECT AND ENGINEER. 6. ALL WORK SHALL BE DONE ACCORDING TO THE CURRENT NATIONAL ELECTRIC CODE (NEC), IBC, NFPA, AND IFC. COMPLIANCE AND FINAL APPROVAL IS SUBJECT TO THE ON SITE FIELD INSPECTION OF THE AHJ. 1. CLARIFICATION METHODS: AT THE TIME OF BIDDING, BIDDERS SHALL FAMILIARIZE THEMSELVES WITH THE DRAWINGS AND SPECIFICATIONS. ANY QUESTIONS, MISUNDERSTANDINGS, CONFLICTS, DELETIONS, DISCONTINUED PRODUCTS, CATALOG NUMBER DISCREPANCIES, DISCREPANCIES BETWEEN THE EQUIPMENT SUPPLIED AND THE INTENT OR FUNCTION OF THE EQUIPMENT, ETC, SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER IN WRITING FOR CLARIFICATION PRIOR TO ISSUANCE OF THE FINAL ADDENDUM AND BIDDING OF THE PROJECT. WHERE DISCREPANCIES OR MULTIPLE INTERPRETATIONS OCCUR, THE MOST STRINGENT (WHICH IS GENERALLY RECOGNIZED AS THE MOST COSTLY) THAT MEETS THE INTENT OF THE DOCUMENTS SHALL BE ENFORCED. 2. OWNER FURNISHED ITEMS: THE OWNER WILL FURNISH MATERIAL AND EQUIPMENT AS INDICATED IN THE CONTRACT DOCUMENTS TO BE INCORPORATED INTO THE WORK. THESE ITEMS ARE ASSIGNED TO THE INSTALLER AND COSTS FOR RECEIVING, HANDLING, STORAGE, IF REQUIRED, AND INSTALLATION ARE INCLUDED IN THE CONTRACT SUM. A. THE INSTALLER'S RESPONSIBILITIES ARE THE SAME AS IF THE INSTALLER FURNISHED THE MATERIALS OR EQUIPMENT. B. THE OWNER WILL ARRANGE AND PAY FOR DELIVERY OF OWNER FURNISHED ITEMS FREIGHT ON BOARD JOB SITE AND THE INSTALLER WILL INSPECT DELIVERIES FOR DAMAGE. IF OWNER FURNISHED ITEMS ARE DAMAGED, DEFECTIVE OR MISSING, DOCUMENT DAMAGED ITEMS WITH THE TRANSPORT COMPANY AND THE OWNER WILL ARRANGE FOR REPLACEMENT. THE OWNER WILL ALSO ARRANGE FOR MANUFACTURER'S FIELD SERVICES, AND THE DELIVERY OF MANUFACTURER'S WARRANTIES AND BONDS TO THE INSTALLER. C. THE INSTALLER IS RESPONSIBLE FOR DESIGNATING THE DELIVERY DATES OF OWNER FURNISHED ITEMS AND FOR RECEIVING, UNLOADING AND HANDLING OWNER FURNISHED ITEMS AT THE SITE.THE  INSTALLER IS RESPONSIBLE FOR PROTECTING OWNER FURNISHED ITEMS FROM DAMAGE, INCLUDING DAMAGE FROM EXPOSURE TO THE ELEMENTS, AND TO REPAIR OR REPLACE ITEMS DAMAGED AS A RESULT OF HIS OPERATIONS. DEFINITIONS NOTE: ALL DEFINITIONS MAY NOT BE USED. INDICATED: THE TERM "INDICATED" REFERS TO GRAPHIC REPRESENTATIONS, NOTES, OR SCHEDULES ON THE DRAWINGS, OTHER PARAGRAPHS OR SCHEDULES IN THE SPECIFICATIONS, AND SIMILAR REQUIREMENTS IN THE CONTRACT DOCUMENTS. WHERE TERMS SUCH AS "SHOWN", "NOTED", "SCHEDULED", AND "SPECIFIED" ARE USED, IT IS TO HELP THE READER LOCATE THE REFERENCE, NO LIMITATION ON LOCATION IS INTENDED. DIRECTED: TERMS SUCH AS "DIRECTED", "REQUESTED", AUTHORIZED", "SELECTED", "APPROVED", "REQUIRED", AND "PERMITTED" MEAN "DIRECTED BY THE ENGINEER", "REQUESTED BY THE ENGINEER", AND SIMILAR PHRASES. APPROVED: THE TERM "APPROVED", WHERE USED IN CONJUNCTION WITH THE ENGINEER'S ACTION ON THE CONTRACTOR'S SUBMITTALS, APPLICATIONS, AND REQUESTS, IS LIMITED TO THE ENGINEER'S DUTIES AND RESPONSIBILITIES AS STATED IN GENERAL AND SUPPLEMENTARY CONDITIONS. FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS." INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT PROJECT SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS." PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE." INSTALLER: AN "INSTALLER" IS THE CONTRACTOR OR AN ENTITY ENGAGED BY THE CONTRACTOR, EITHER AS AN EMPLOYEE, SUBCONTRACTOR, OR SUB - SUBCONTRACTOR, FOR PERFORMANCE OF A PARTICULAR CONSTRUCTION ACTIVITY, INCLUDING INSTALLATION, ERECTION, APPLICATION, AND SIMILAR OPERATIONS. INSTALLERS ARE REQUIRED TO BE EXPERIENCED IN THE OPERATIONS THEY ARE ENGAGED TO PERFORM. TECHNOLOGY SYSTEMS: THE TERM "TECHNOLOGY SYSTEMS" IS USED TO DESCRIBE ALL LOW VOLTAGE SYSTEMS GENERALLY REFERRED TO AS "SPECIAL SYSTEMS". THESE SYSTEMS INCLUDE BUT ARE NOT NECESSARILY LIMITED TO ALL SYSTEMS WHICH UTILIZE VOLTAGES OF LESS THAN 71 VOLTS SUCH AS SOUND SYSTEMS, VIDEO SYSTEMS, TV SYSTEMS, SECURITY SYSTEMS, VOICE AND DATA CABLING SYSTEMS, ETC... ABBREVIATIONS NOTE: ALL ABBREVIATIONS MAY NOT BE USED. IR INFRARED J-BOX JUNCTION BOX kV KILOVOLT kVA KILOVOLT AMPERE kVAR KILOVOLT AMPERE REACTIVE kW KILOWATT kWh KILOWATT HOUR LED LIGHT EMITTING DIODE LFMC LIQUID TIGHT FLEXIBLE METAL CONDUIT LFNC LIQUID TIGHT FLEXIBLE NONMETALLIC CONDUIT LPS LOW PRESSURE SODIUM LRA LOCKED ROTOR AMPS LTG LIGHTING LV LOW VOLTAGE MATV MASTER ANTENNA TELEVISION SYSTEM MAX MAXIMUM MC METAL CLAD MCA MINIMUM CIRCUIT AMPS MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MCP MOTOR CIRCUIT PROTECTION MDP MAIN DISTRIBUTION PANEL MG MOTOR GENERATOR MH MANHOLE MIN MINIMUM MLO MAIN LUGS ONLY MOCP MAXIMUM OVERCURRENT PROTECTION NA NOT APPLICABLE NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NEMA NATIOANL ELECTRICAL MANUFACTURERS ASSOCIATION NFC NATIONAL FIRE CODE NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT NL NIGHT LIGHT NO NORMALLY OPEN NTS NOT TO SCALE OC ON CENTER OCP OVER CURRENT PROTECTION OF/CI OWNER FURNISHED/ CONTRACTOR INSTALLED OF/OI OWNER FURNISHED/ OWNER INSTALLED OFP OBTAIN FROM PLANS OH DR OVERHEAD (COILING) DOOR OL OVERLOAD PB PUSHBUTTON PF POWER FACTOR PH PHASE PNL PANEL PT POTENTIAL TRANSFORMER PTZ PAN/TILT/ZOOM QTY QUANTITY R REMOVE RCP REFLECTED CEILING PLAN RMC RIGID METAL CONDUIT RNC RIGID NONMETAL CONDUIT RPM REVOLUTIONS PER MINUTE RR REMOVE AND RELOCATE S/S START/STOP SCA SHORT CIRCUIT AMPS SCBA STANDARD COLOR AS SELECTED BY ARCHITECT SF SQUARE FOOT (FEET) SFBA STANDARD FINISH AS SELECTED BY ARCHITECT SPD SURGE PROTECTIVE DEVICE SPDT SINGLE POLE, DOUBLE THROW SPEC SPECIFICATION SPST SINGLE POLE, SINGLE THROW ST SINGLE THROW SWBD SWITCHBOARD SWGR SWITCHGEAR TL TWIST LOCK TP TELEPHONE POLE TP TWISTED PAIR TTB TELEPHONE TERMINAL BOARD TV TELEVISION TVSS TRANSIENT VOLTAGE SURGE SUPPRESSER TYP TYPICAL UF UNDERFLOOR UGND UNDERGROUND UPS UNINTERRUPTIBLE POWER SUPPLY V VOLTS VA VOLT AMPERE VFC/VF D VARIABLE FREQUENCY MOTOR CONTROLLER W/ WITH W/O WITHOUT WP WEATHERPROOF XFMR TRANSFORMER 1P SINGLE POLE 1PH SINGLE-PHASE 1WAY ONE-WAY 2/C TWO-CONDUCTOR 2WAY TWO-WAY 3/C THREE-CONDUCTOR 3WAY THREE-WAY 4OUT QUADRUPLE RECEPTACLE OUTLET 4PDT FOUR-POLE DOUBLE THROW 4PST FOUR-POLE SINGLE THROW 4W FOUR-WIRE 4WAY FOUR-WAY A ABOVE COUNTER AC ARMORED CABLE ADA AMERICANS WITH DISABILITIES ACT ADJ ADJACENT AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AMPERE INTERRUPTING CAPACITY ALUM ALUMINUM AMP AMPERE ANN ANNUNCIATOR AP ACCESS POINT (WIRELESS DATA) AR AS REQUIRED ASC AMPS SHORT CIRCUIT ATS AUTOMATIC TRANSFER SWITCH AV AUDIO VISUAL AWG AMERICAN WIRE GAGE BB XFMR BUCK-BOOST TRANSFORMER C CEILING MOUNTED CATV COMMUNITY ANTENNA TELEVISION CB CIRCUIT BREAKER CCBA CUSTOM COLOR AS SELECTED BY ARCHITECT CCTV CLOSED CIRCUIT TELEVISION CF/CI CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED CF/OI CONTRACTOR FURNISHED/ OWNER INSTALLED CFBA CUSTOM FINISH AS SELECTED BY ARCHITECT CKT CIRCUIT CM CONSTRUCTION MANAGER CND CONDUIT CO CONVENIENCE OUTLET COR CONTRACTING OFFICER'S REPRESENTATIVE CP CONTROL PANEL CT CURRENT TRANSFORMER CTV CABLE TELEVISION CU COPPER dBA UNIT OF SOUND LEVEL DPDT DOUBLE POLE, DOUBLE THROW DS DISCONNECT SWITCH EA EACH EM EMERGENCY EMT ELECTRICAL METALLIC TUBING ENT ELECTRIC NONMETALLIC TUBING EPO EMERGENCY POWER OFF EQUIP EQUIPMENT EX EXISTING F FURNITURE MOUNTED FA FIRE ALARM FCP FIRE ALARM CONTROL PANEL FLA FULL LOAD AMPS FMC FLEXIBLE METAL CONDUIT FOB FREIGHT ON BOARD FVNR FULL VOLTAGE NON-REVERSING FVR FULL VOLTAGE REVERSING G GROUND GEN GENERATOR GFCI GROUND FAULT INTERRUPTER GFP GROUND FAULT PROTECTION HD HEAVY DUTY HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTOMATIC HP HORSE POWER HPF HIGH POWER FACTOR HPS HIGH PRESSURE SODIUM HV HIGH VOLTAGE HZ HERTZ I/O INPUT/ OUTPUT IG ISOLATED GROUND IMC INTERMEDIATE METAL CONDUIT IN/IS INSULATED/ ISOLATED SYMBOL DESCRIPTION SYMBOLS LEGEND SYMBOL DESCRIPTION SYMBOLS LEGEND SWITCH, WEATHERPROOF. WP RECEPTACLE, DUPLEX, TAMPER RESISTANT: NEMA 5-20R. T SWITCH, OCCUPANCY SENSOR. OS SWITCH, TIMER OPERATED. T FLUSH FLOOR BOX. "#" SHOWN ON DRAWINGS. REFER TO WIRING DEVICE SCHEDULE IN THE ELECTRICAL SPECIFICATIONS FOR CONFIGURATION AND DEVICES. FB# SWITCH, DIMMER. D SWITCH, SINGLE POLE ("x" INDICATES FIXTURES CONTROLLED). X RECEPTACLE, QUADRAPLEX: NEMA 5-20R. RECEPTACLE, SPECIAL PURPOSE. PROVIDE RECEPTACLE TO MATCH EQUIPMENT PLUG. RECEPTACLE, DUPLEX, WEATHERPROOF: NEMA 5-20R. WP RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER: NEMA 5-20R. RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER, WEATHERPROOF: NEMA 5-20R. WP RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER, WET LABEL, "WEATHERPROOF IN USE": NEMA 5-20R. W S RECEPTACLE, DUPLEX, SWITCHED: NEMA 5-20R. RECEPTACLE, DUPLEX, ISOLATED GROUND: NEMA 5-20R. IG DF RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER, DRINKING FOUNTAIN: CONCEAL WATER COOLER RECEPTACLE BEHIND WATER COOLER. SEE MECHANICAL/PLUMBING SHOP DRAWINGS FOR INSTALLATION REQUIREMENTS. RECEPTACLE, DUPLEX, CEILING: NEMA 5-20R. C RECEPTACLE, DUPLEX, ABOVE COUNTER: NEMA 5-20R. A RECEPTACLE, DUPLEX: NEMA 5-20R. WIRING DEVICES SITE ELECTRICAL AND COMMUNICATIONS UTILITIES 3ØUP ELECTRIC LINE: THIN LINE. 1Ø = SINGLE PHASE, 2Ø = 2-PHASE, 3Ø = 3-PHASE, O = OVERHEAD, U = UNDERGROUND, P = PRIMARY, S = SECONDARY LIGHTNING ARRESTOR. UTILITY POLE. UTILITY, DISTRIBUTION SWITCH OR SWITCHING STATION. UTILITY, PRIMARY ELECTRICAL HAND HOLE. E UTILITY SERVICES, MANHOLE. M UTILITY, COMMUNICATIONS MANHOLE. C UTILITY, ELECTRICAL MANHOLE. E UTILITY, TELEPHONE MANHOLE. T PRECAST CONCRETE, COMMUNICATION VAULT. C PRECAST CONCRETE, ELECTRICAL VAULT. E PRECAST CONCRETE, TELEPHONE VAULT. T PRECAST CONCRETE, MANHOLE, TRANSFORMER VAULT. TM PRECAST CONCRETE, TRANSFORMER PAD. TP TRANSFORMER. T HAND HOLE. H SUBSTATION. S LIGHTING CONTROL STATION. DIMMING ENTRY STATION OR CONTROL STATION, FLUSH MOUNTED. 75 TRANSFORMER: NUMBER INDICATES kVA. PUSHBUTTON. PUSHBUTTONS, MOTOR CONTROL. PANELBOARD CABINET, SURFACE MOUNTED, 1 SECTION. PANELBOARD CABINET, SURFACE MOUNTED, 2 SECTION. DP#__ DISTRIBUTION PANEL OR SWITCHBOARD. SERVICE ENTRANCE SURGE PROTECTION (ONE-LINE DIAGRAM). PANELBOARD (ONE-LINE DIAGRAM). "1H" PANELBOARD WITH MAIN CIRCUIT BREAKER. SIZE AND PHASE AS SHOWN (ONE-LINE DIAGRAM). 225/3 "1H" PANELBOARD WITH MAIN AND SUB FEED CIRCUIT BREAKER (ONE-LINE DIAGRAM). 60/3 225/3 "1H" PANELBOARD WITH MAIN LUGS ONLY AND SURGE PROTECTION WITH CIRCUIT BREAKER (ONE-LINE DIAGRAM). 25/3 225/3 "1H" TRANSFORMER (ONE-LINE DIAGRAM). EXHAUST FAN OUTLET. F CIRCUIT BREAKER, MOLDED CASE (ONE-LINE DIAGRAM). CIRCUIT BREAKER, MOLDED CASE WITH SHUNT TRIP (ONE-LINE DIAGRAM). CIRCUIT BREAKER, MOTOR CIRCUIT PROTECTION (ONE-LINE DIAGRAM). MCP ELECTRICAL POWER AND DISTRIBUTION EXIT SIGN: DOUBLE FACE; WALL MOUNTED EXIT SIGN: SINGLE FACE; CEILING MOUNTED EXIT SIGN: DOUBLE FACE; CEILING MOUNTED EXIT SIGN: SINGLE FACE; WALL MOUNTED LIGHTING (REFER TO FIXTURE SCHEDULE FOR SYMBOLS) FIXTURE IDENTIFICATION: (W-3) INDICATES FIXTURE TYPE AS SCHEDULED. (W-3) FIXTURE IDENTIFICATION, EMERGENCY WITH BATTERY PACK, AS INDICATED: (EX-X) INDICATES FIXTURE TYPE AS SCHEDULED. (EX-X) EM EMERGENCY. NL NIGHT LIGHT: DO NOT SWITCH. EGRESS DIRECTION ARROW (EXIT SIGNS). LOW VOLTAGE LIGHTING TRANSFORMER. LV VACANCY SENSOR, DUAL TECHNOLOGY, WALL. VACANCY SENSOR, DUAL TECHNOLOGY, OMNI-DIRECTIONAL, CEILING. LIGHTING CONTROL OCCUPANCY SENSOR, DUAL TECHNOLOGY, OMNI-DIRECTIONAL, CEILING. OCCUPANCY SENSOR, DUAL TECHNOLOGY, WALL. OCCUPANCY SENSOR, DUAL TECHNOLOGY, DIRECTIONAL. OCCUPANCY SENSOR, ULTRASONIC, OMNI-DIRECTIONAL, CEILING. U PHOTOCELL. P TWO-WAY EMERGENCY COMMUNICATION DEVICE PER IBC, WALL MOUNTED IN RECESSED BOX. STRUCTURED CABLING TELEPHONE, WALL MOUNTED ("X" INDICATES QUANTITY OF CABLES). X DATA CONNECTION: WIRELESS ACCESS POINT (WAP). REQUIRES (2) DATA DROPS PER DEVICE TELEPHONE, WALL MOUNTED: WALL PHONE. W OUTLET, DATA COMMUNICATION ("X" INDICATES QUANTITY OF CABLES). X OUTLET, BUILDING STANDARD COMBINATION TELEPHONE/ DATA COMMUNICATION. TELEPHONE TERMINAL BOARD, FIRE TREATED PLYWOOD PAINTED. LAN RACK, FLOOR STANDING. DATA CABLE, CATEGORY 5 (ONE-LINE DIAGRAM). D VOICE CABLE, CATEGORY 3 (ONE-LINE DIAGRAM). V 10 HIDDEN FEATURES LINE: HIDDEN, THIN LINE NEW LINE: MEDIUM LINE. CU-1 EQUIPMENT INDICATOR. REVISION INDICATOR. 1 KEYNOTE INDICATOR. 1 ROOM IDENTIFIER WITH ROOM NAME AND NUMBER. ROOM NAME 100 DETAIL INDICATOR: A5 INDICATES DETAIL NUMBER, E-501 INDICATES DRAWING SHEET WHERE DETAIL IS SHOWN. A5 E-501 REFERENCE AND LINE SYMBOLS MECHANICAL EQUIPMENT CONNECTION. REFER TO EQUIPMENT SCHEDULE FOR REQUIREMENTS. JUNCTION BOX, CEILING. C J EARTH GROUND (ONE-LINE DIAGRAM). JUNCTION BOX, SECURITY SYSTEM. PROVIDE CONDUIT AND ROUGH-IN PER SECURITY DRAWINGS. SE J JUNCTION BOX. J ADA ACCESS PUSH PLATE HC CONDUCTOR & CONDUIT ("CC") SCHEDULE INDICATOR. REFER TO ONE-LINE DIAGRAM. 1 LOW VOLTAGE WIRING: DIVIDE, MEDIUM LINE. WIRING AND/OR RACEWAY: THIN LINE. WHERE "X" = : CATV = CABLE TELEVISION NC = NURSE CALL CCTV = CLOSED CIRCUIT P = POWER TELEVISION RC = RIGID CONDUIT FA = FIRE ALARM S = SOUND FO = FIBER OPTICS T = TELEPHONE I = INTERCOM TV = TELEVISION OTHERS AS NOTED IN OTHER SCHEDULES. RACEWAYS AND WIRING SHALL BE SIZED AS SHOWN AND/OR SPECIFIED. X BRANCH CIRCUIT HOME RUN TO PANELBOARD: NUMBER OF ARROWS INDICATES NUMBER OF CIRCUITS. LETTER AND NUMBER NOTATIONS IDENTIFY PANEL AND CIRCUIT NUMBERS. USE #12 CONDUCTORS, EXCEPT #10 CONDUCTORS SHALL BE INSTALLED IF DISTANCES EXCEED THOSE SPECIFIED IN THE ELECTRICAL SPECIFICATIONS. A-1,3,5 WIRING. WIRING METHODS CCTV CCTV CABLE, POWER. P CCTV CABLE, VIDEO SIGNAL. V CCTV CCTV HEADEND EQUIPMENT. CCTV MONITOR. M CCTV CAMERA/ENCLOSURE WITH LENS, TYPICAL. SEE SCHEDULE. CCTV CAMERA WITH PAN, TILT AND ZOOM. PTZ PANNING CAMERA TRANSVERSE ANGLE. 360° MASTER STATION, INTERCOM. MSI ANNUNCIATOR PANEL. AP ULTRASONIC MOTION DETECTOR. U PANIC DURESS SWITCH. P PASSIVE INFRARED SENSOR. IR DUAL TECHNOLOGY PASSIVE INFRARED SENSOR AND ULTRASONIC MOTION DETECTOR. IRU INTERCOM STATION. IC CONTROLLED ACCESS POINT. CA SENSOR, VOLUMETRIC. SENSOR, GLASS BREAK. SENSOR, BURIED VEHICULAR. BUZZER, COMBINATION BELL. BUZZER. BELL. REMOTE DOOR RELEASE BUTTON. RL EXIT REQUEST. ER DOOR SWITCH, BALANCED MAGNETIC CONTROL. KEYPAD/CARD READER COMBINATION. KCR CARD READER. CR CARD ACCESS DOOR TYPE #1 OR AS NOTED. SEE SCHEDULE. #1 INTRUSION DETECTION HEADEND EQUIPMENT. SEC SECURITY CONTROL PANEL. CTR ACCESS CONTROL HEADEND EQUIPMENT. ACC SECURITY CABLE. SEE EQUIPMENT SCHEDULE FOR CABLE TYPE. X SECURITY TERMINATOR, 75 OHM (TV DISTRIBUTION). TV ANTENNA (ONE-LINE DIAGRAM). SATELLITE ANTENNA. TV OUTLET. TV DISTRIBUTION TV DISTRIBUTION CABLE, INDIVIDUAL DROPS. T TV DISTRIBUTION CABLE, TRUNK. TR COMBINER. CMB DIRECTIONAL COUPLER. DC DISTRIBUTION AMPLIFIER (ONE-LINE DIAGRAM). DA SPLITTER (ONE-LINE DIAGRAM). SPL SYMBOL DESCRIPTION SYMBOLS LEGEND 1 10-17-17 ADDENDUM #1 C SB CORD REEL. SEE DETAIL SPIDER BOX. SEE DETAIL C3 SHEET ES502. 1 1 1

SYMBOLS LEGEND GSB - arnell-west.comarnell-west.com/wp-content/uploads/2017/10/Addendum-1-Drawings.pdf · es601 one-line diagram es602 panel schedules es603 equipment schedule es701

  • Upload
    others

  • View
    23

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SYMBOLS LEGEND GSB - arnell-west.comarnell-west.com/wp-content/uploads/2017/10/Addendum-1-Drawings.pdf · es601 one-line diagram es602 panel schedules es603 equipment schedule es701

375 WEST 200 SOUTHSALT LAKE CITY, UT

84101

801.521.8600801.521.7913

PF

www.gsbsarchitects.com

OWNER PROJECT NO.:GSBS PROJECT NO.:ISSUED DATE:

REVISIONS:

GSBARCHITEC

PLSPR201700272

Contsruction Ducuments

06/02/2017

2015.122.00

ES001

SHEET INDEX,ABBREVIATIONS, ANDGENERAL NOTES

City of South Jordan

Highland Park

Daybreak Village 8South Jordan, UT

10996 S. Redwood RoadSouth Jordan, UT 84095

ELECTRICAL SHEET INDEXES001 SHEET INDEX, ABBREVIATIONS, AND GENERAL NOTES

ES101 SITE ELECTRICAL PLAN

ES102 SITE ELECTRICAL PLAN - PHASE 1

ES103 SITE ELECTRICAL PLAN - PHASE 2

ES201 PHASE 1 ENLARGED ELECTRICAL PLAN - CONCESSIONS AND RESTROOM

ES202 PHASE 1 ENLARGED ELECTRICAL PLAN - PAVILION AND STORAGE SHED

ES203 PHASE 2 ENLARGED ELECTRICAL PLAN - PAVILION AND RESTROOM

ES204 SITE SPORTS FIELD PHOTOMETRICS

ES205 MUSCO PHOTOMETRICS

ES501 SITE ELECTRICAL DETAILS

ES502 SITE ELECTRICAL DETAILS

ES601 ONE-LINE DIAGRAM

ES602 PANEL SCHEDULES

ES603 EQUIPMENT SCHEDULE

ES701 TYPICAL MOUNTING HEIGHT DETAILS

GENERAL ELECTRICAL NOTES

3. EXPOSED STRUCTURE AREAS (EXCLUDING MECHANICAL, ELECTRICAL, ANDCOMMUNICATION SPACES): INSTALL RACEWAYS BETWEEN DECK ANDSTRUCTURE WHEREVER POSSIBLE IN EXPOSED STRUCTURE CEILING AREAS.ROUTE RACEWAYS IN CONCEALED AREAS WHEREVER POSSIBLE. REFER ALLCONDITIONS WHERE RACEWAYS MUST BE INSTALLED WHICH CANNOT COMPLYWITH THESE REQUIREMENTS TO THE ARCHITECT.

4. SUBMITTALS: PROVIDE ORIGINAL ELECTRONIC PDF FORMAT, BOUND,BOOKMARKED (EACH SECTION AND PRODUCT), AND HIGHLIGHTED. JOB NAMEAND SUBCONTRACTOR SHALL BE ON THE FRONT COVER. PREPARE INDEX OFEQUIPMENT SUBMITTED IN EACH TAB.

5. REFLECTED CEILING PLANS: COORDINATE THE LOCATION OF LIGHT FIXTURESWITH THE ARCHITECTURAL REFLECTED CEILING PLANS. REFER ALLDISCREPANCIES TO THE ARCHITECT AND ENGINEER.

6. ALL WORK SHALL BE DONE ACCORDING TO THE CURRENT NATIONAL ELECTRICCODE (NEC), IBC, NFPA, AND IFC. COMPLIANCE AND FINAL APPROVAL IS SUBJECTTO THE ON SITE FIELD INSPECTION OF THE AHJ.

1. CLARIFICATION METHODS: AT THE TIME OF BIDDING, BIDDERS SHALL FAMILIARIZETHEMSELVES WITH THE DRAWINGS AND SPECIFICATIONS. ANY QUESTIONS,MISUNDERSTANDINGS, CONFLICTS, DELETIONS, DISCONTINUED PRODUCTS,CATALOG NUMBER DISCREPANCIES, DISCREPANCIES BETWEEN THE EQUIPMENTSUPPLIED AND THE INTENT OR FUNCTION OF THE EQUIPMENT, ETC, SHALL BESUBMITTED TO THE ARCHITECT/ENGINEER IN WRITING FOR CLARIFICATION PRIORTO ISSUANCE OF THE FINAL ADDENDUM AND BIDDING OF THE PROJECT. WHEREDISCREPANCIES OR MULTIPLE INTERPRETATIONS OCCUR, THE MOST STRINGENT(WHICH IS GENERALLY RECOGNIZED AS THE MOST COSTLY) THAT MEETS THEINTENT OF THE DOCUMENTS SHALL BE ENFORCED.

2. OWNER FURNISHED ITEMS: THE OWNER WILL FURNISH MATERIAL ANDEQUIPMENT AS INDICATED IN THE CONTRACT DOCUMENTS TO BE INCORPORATEDINTO THE WORK. THESE ITEMS ARE ASSIGNED TO THE INSTALLER AND COSTSFOR RECEIVING, HANDLING, STORAGE, IF REQUIRED, AND INSTALLATION AREINCLUDED IN THE CONTRACT SUM.

A. THE INSTALLER'S RESPONSIBILITIES ARE THE SAME AS IF THE INSTALLERFURNISHED THE MATERIALS OR EQUIPMENT.

B. THE OWNER WILL ARRANGE AND PAY FOR DELIVERY OF OWNERFURNISHED ITEMS FREIGHT ON BOARD JOB SITE AND THE INSTALLER WILLINSPECT DELIVERIES FOR DAMAGE. IF OWNER FURNISHED ITEMS AREDAMAGED, DEFECTIVE OR MISSING, DOCUMENT DAMAGED ITEMS WITHTHE TRANSPORT COMPANY AND THE OWNER WILL ARRANGEFOR REPLACEMENT. THE OWNER WILL ALSO ARRANGE FORMANUFACTURER'S FIELD SERVICES, AND THE DELIVERY OFMANUFACTURER'S WARRANTIES AND BONDS TO THE INSTALLER.

C. THE INSTALLER IS RESPONSIBLE FOR DESIGNATING THE DELIVERY DATESOF OWNER FURNISHED ITEMS AND FOR RECEIVING, UNLOADING ANDHANDLING OWNER FURNISHED ITEMS AT THE SITE.THE  INSTALLER ISRESPONSIBLE FOR PROTECTING OWNER FURNISHED ITEMS FROMDAMAGE, INCLUDING DAMAGE FROM EXPOSURE TO THE ELEMENTS, ANDTO REPAIR OR REPLACE ITEMS DAMAGED AS A RESULT OF HISOPERATIONS.

DEFINITIONSNOTE: ALL DEFINITIONS MAY NOT BE USED.

INDICATED: THE TERM "INDICATED" REFERS TO GRAPHIC REPRESENTATIONS, NOTES, OR SCHEDULES ON THE DRAWINGS, OTHER PARAGRAPHS OR SCHEDULES IN THE SPECIFICATIONS, AND SIMILAR REQUIREMENTS IN THE CONTRACT DOCUMENTS. WHERE TERMS SUCH AS "SHOWN", "NOTED", "SCHEDULED", AND "SPECIFIED" ARE USED, IT IS TO HELP THE READER LOCATE THE REFERENCE, NO LIMITATION ON LOCATION IS INTENDED.

DIRECTED: TERMS SUCH AS "DIRECTED", "REQUESTED", AUTHORIZED", "SELECTED", "APPROVED", "REQUIRED", AND "PERMITTED" MEAN "DIRECTED BY THE ENGINEER", "REQUESTED BY THE ENGINEER", AND SIMILAR PHRASES.

APPROVED: THE TERM "APPROVED", WHERE USED IN CONJUNCTION WITH THE ENGINEER'S ACTION ON THE CONTRACTOR'S SUBMITTALS, APPLICATIONS, AND REQUESTS, IS LIMITED TO THE ENGINEER'S DUTIES AND RESPONSIBILITIES AS STATED IN GENERAL AND SUPPLEMENTARY CONDITIONS.

FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS."

INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT PROJECT SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS."

PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE."

INSTALLER: AN "INSTALLER" IS THE CONTRACTOR OR AN ENTITY ENGAGED BY THE CONTRACTOR, EITHER AS AN EMPLOYEE, SUBCONTRACTOR, OR SUB-SUBCONTRACTOR, FOR PERFORMANCE OF A PARTICULAR CONSTRUCTION ACTIVITY, INCLUDING INSTALLATION, ERECTION, APPLICATION, AND SIMILAR OPERATIONS. INSTALLERS ARE REQUIRED TO BE EXPERIENCED IN THE OPERATIONS THEY ARE ENGAGED TO PERFORM.

TECHNOLOGY SYSTEMS: THE TERM "TECHNOLOGY SYSTEMS" IS USED TO DESCRIBE ALL LOW VOLTAGE SYSTEMS GENERALLY REFERRED TO AS "SPECIAL SYSTEMS". THESE SYSTEMS INCLUDE BUT ARE NOT NECESSARILY LIMITED TO ALL SYSTEMS WHICH UTILIZE VOLTAGES OF LESS THAN 71 VOLTS SUCH AS SOUND SYSTEMS, VIDEO SYSTEMS, TV SYSTEMS, SECURITY SYSTEMS, VOICE AND DATA CABLING SYSTEMS, ETC...

ABBREVIATIONSNOTE: ALL ABBREVIATIONS MAY NOT BE USED.

IR INFRARED

J-BOX JUNCTION BOX

kV KILOVOLT

kVA KILOVOLT AMPERE

kVAR KILOVOLT AMPERE REACTIVE

kW KILOWATT

kWh KILOWATT HOUR

LED LIGHT EMITTING DIODE

LFMC LIQUID TIGHT FLEXIBLE METALCONDUIT

LFNC LIQUID TIGHT FLEXIBLENONMETALLIC CONDUIT

LPS LOW PRESSURE SODIUM

LRA LOCKED ROTOR AMPS

LTG LIGHTING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISIONSYSTEM

MAX MAXIMUM

MC METAL CLAD

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MCP MOTOR CIRCUIT PROTECTION

MDP MAIN DISTRIBUTION PANEL

MG MOTOR GENERATOR

MH MANHOLE

MIN MINIMUM

MLO MAIN LUGS ONLY

MOCP MAXIMUM OVERCURRENTPROTECTION

NA NOT APPLICABLE

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIOANL ELECTRICALMANUFACTURERSASSOCIATION

NFC NATIONAL FIRE CODE

NFPA NATIONAL FIRE PROTECTIONASSOCIATION

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NTS NOT TO SCALE

OC ON CENTER

OCP OVER CURRENT PROTECTION

OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED

OF/OI OWNER FURNISHED/ OWNERINSTALLED

OFP OBTAIN FROM PLANS

OH DR OVERHEAD (COILING) DOOR

OL OVERLOAD

PB PUSHBUTTON

PF POWER FACTOR

PH PHASE

PNL PANEL

PT POTENTIAL TRANSFORMER

PTZ PAN/TILT/ZOOM

QTY QUANTITY

R REMOVE

RCP REFLECTED CEILING PLAN

RMC RIGID METAL CONDUIT

RNC RIGID NONMETAL CONDUIT

RPM REVOLUTIONS PER MINUTE

RR REMOVE AND RELOCATE

S/S START/STOP

SCA SHORT CIRCUIT AMPS

SCBA STANDARD COLOR ASSELECTED BY ARCHITECT

SF SQUARE FOOT (FEET)

SFBA STANDARD FINISH ASSELECTED BY ARCHITECT

SPD SURGE PROTECTIVE DEVICE

SPDT SINGLE POLE, DOUBLE THROW

SPEC SPECIFICATION

SPST SINGLE POLE, SINGLE THROW

ST SINGLE THROW

SWBD SWITCHBOARD

SWGR SWITCHGEAR

TL TWIST LOCK

TP TELEPHONE POLE

TP TWISTED PAIR

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

TVSS TRANSIENT VOLTAGE SURGESUPPRESSER

TYP TYPICAL

UF UNDERFLOOR

UGND UNDERGROUND

UPS UNINTERRUPTIBLE POWERSUPPLY

V VOLTS

VA VOLT AMPERE

VFC/VFD

VARIABLE FREQUENCY MOTORCONTROLLER

W/ WITH

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

1P SINGLE POLE

1PH SINGLE-PHASE

1WAY ONE-WAY

2/C TWO-CONDUCTOR

2WAY TWO-WAY

3/C THREE-CONDUCTOR

3WAY THREE-WAY

4OUT QUADRUPLE RECEPTACLEOUTLET

4PDT FOUR-POLE DOUBLE THROW

4PST FOUR-POLE SINGLE THROW

4W FOUR-WIRE

4WAY FOUR-WAY

A ABOVE COUNTER

AC ARMORED CABLE

ADA AMERICANS WITH DISABILITIESACT

ADJ ADJACENT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AIC AMPERE INTERRUPTINGCAPACITY

ALUM ALUMINUM

AMP AMPERE

ANN ANNUNCIATOR

AP ACCESS POINT (WIRELESSDATA)

AR AS REQUIRED

ASC AMPS SHORT CIRCUIT

ATS AUTOMATIC TRANSFERSWITCH

AV AUDIO VISUAL

AWG AMERICAN WIRE GAGE

BBXFMR

BUCK-BOOST TRANSFORMER

C CEILING MOUNTED

CATV COMMUNITY ANTENNATELEVISION

CB CIRCUIT BREAKER

CCBA CUSTOM COLOR AS SELECTEDBY ARCHITECT

CCTV CLOSED CIRCUIT TELEVISION

CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED

CFBA CUSTOM FINISH AS SELECTEDBY ARCHITECT

CKT CIRCUIT

CM CONSTRUCTION MANAGER

CND CONDUIT

CO CONVENIENCE OUTLET

COR CONTRACTING OFFICER'SREPRESENTATIVE

CP CONTROL PANEL

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CU COPPER

dBA UNIT OF SOUND LEVEL

DPDT DOUBLE POLE, DOUBLETHROW

DS DISCONNECT SWITCH

EA EACH

EM EMERGENCY

EMT ELECTRICAL METALLIC TUBING

ENT ELECTRIC NONMETALLICTUBING

EPO EMERGENCY POWER OFF

EQUIP EQUIPMENT

EX EXISTING

F FURNITURE MOUNTED

FA FIRE ALARM

FCP FIRE ALARM CONTROL PANEL

FLA FULL LOAD AMPS

FMC FLEXIBLE METAL CONDUIT

FOB FREIGHT ON BOARD

FVNR FULL VOLTAGENON-REVERSING

FVR FULL VOLTAGE REVERSING

G GROUND

GEN GENERATOR

GFCI GROUND FAULT INTERRUPTER

GFP GROUND FAULT PROTECTION

HD HEAVY DUTY

HID HIGH INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

HP HORSE POWER

HPF HIGH POWER FACTOR

HPS HIGH PRESSURE SODIUM

HV HIGH VOLTAGE

HZ HERTZ

I/O INPUT/ OUTPUT

IG ISOLATED GROUND

IMC INTERMEDIATE METALCONDUIT

IN/IS INSULATED/ ISOLATED

SYMBOL DESCRIPTION

SYMBOLS LEGENDSYMBOL DESCRIPTION

SYMBOLS LEGEND

SWITCH, WEATHERPROOF.WP

RECEPTACLE, DUPLEX, TAMPER RESISTANT: NEMA 5-20R.T

SWITCH, OCCUPANCY SENSOR.OS

SWITCH, TIMER OPERATED.T

FLUSH FLOOR BOX. "#" SHOWN ON DRAWINGS. REFER TOWIRING DEVICE SCHEDULE IN THE ELECTRICAL SPECIFICATIONSFOR CONFIGURATION AND DEVICES.

FB#

SWITCH, DIMMER.D

SWITCH, SINGLE POLE ("x" INDICATES FIXTURES CONTROLLED).X

RECEPTACLE, QUADRAPLEX: NEMA 5-20R.

RECEPTACLE, SPECIAL PURPOSE. PROVIDE RECEPTACLE TOMATCH EQUIPMENT PLUG.

RECEPTACLE, DUPLEX, WEATHERPROOF: NEMA 5-20R.WP

RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUITINTERRUPTER: NEMA 5-20R.

RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUITINTERRUPTER, WEATHERPROOF: NEMA 5-20R.WP

RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER, WET LABEL, "WEATHERPROOF IN USE": NEMA 5-20R.W

S RECEPTACLE, DUPLEX, SWITCHED: NEMA 5-20R.

RECEPTACLE, DUPLEX, ISOLATED GROUND: NEMA 5-20R.IG

DF

RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER, DRINKING FOUNTAIN: CONCEAL WATER COOLER RECEPTACLE BEHIND WATER COOLER. SEE MECHANICAL/PLUMBING SHOP DRAWINGS FOR INSTALLATION REQUIREMENTS.

RECEPTACLE, DUPLEX, CEILING: NEMA 5-20R.C

RECEPTACLE, DUPLEX, ABOVE COUNTER: NEMA 5-20R.A

RECEPTACLE, DUPLEX: NEMA 5-20R.

WIRING DEVICES

SITE ELECTRICAL AND COMMUNICATIONS UTILITIES

3ØUPELECTRIC LINE: THIN LINE. 1Ø = SINGLE PHASE,2Ø = 2-PHASE, 3Ø = 3-PHASE, O = OVERHEAD,U = UNDERGROUND, P = PRIMARY, S = SECONDARY

LIGHTNING ARRESTOR.

UTILITY POLE.

UTILITY, DISTRIBUTION SWITCH OR SWITCHING STATION.

UTILITY, PRIMARY ELECTRICAL HAND HOLE.E

UTILITY SERVICES, MANHOLE.M

UTILITY, COMMUNICATIONS MANHOLE.C

UTILITY, ELECTRICAL MANHOLE.E

UTILITY, TELEPHONE MANHOLE.T

PRECAST CONCRETE, COMMUNICATION VAULT.C

PRECAST CONCRETE, ELECTRICAL VAULT.E

PRECAST CONCRETE, TELEPHONE VAULT.T

PRECAST CONCRETE, MANHOLE, TRANSFORMER VAULT.TM

PRECAST CONCRETE, TRANSFORMER PAD.TP

TRANSFORMER.T

HAND HOLE.H

SUBSTATION.S

LIGHTING CONTROL STATION.

DIMMING ENTRY STATION OR CONTROL STATION, FLUSHMOUNTED.

75 TRANSFORMER: NUMBER INDICATES kVA.

PUSHBUTTON.

PUSHBUTTONS, MOTOR CONTROL.

PANELBOARD CABINET, SURFACE MOUNTED, 1 SECTION.

PANELBOARD CABINET, SURFACE MOUNTED, 2 SECTION.

DP#__DISTRIBUTION PANEL OR SWITCHBOARD.

SERVICE ENTRANCE SURGE PROTECTION (ONE-LINE DIAGRAM).

PANELBOARD (ONE-LINE DIAGRAM)."1H"

PANELBOARD WITH MAIN CIRCUIT BREAKER. SIZE AND PHASE ASSHOWN (ONE-LINE DIAGRAM).

225/3

"1H"

PANELBOARD WITH MAIN AND SUB FEED CIRCUIT BREAKER(ONE-LINE DIAGRAM).

60/3

225/3

"1H"

PANELBOARD WITH MAIN LUGS ONLY AND SURGE PROTECTIONWITH CIRCUIT BREAKER (ONE-LINE DIAGRAM).

25/3

225/3

"1H"

TRANSFORMER (ONE-LINE DIAGRAM).

EXHAUST FAN OUTLET.F

CIRCUIT BREAKER, MOLDED CASE (ONE-LINE DIAGRAM).

CIRCUIT BREAKER, MOLDED CASE WITH SHUNT TRIP(ONE-LINE DIAGRAM).

CIRCUIT BREAKER, MOTOR CIRCUIT PROTECTION(ONE-LINE DIAGRAM).

MCP

ELECTRICAL POWER AND DISTRIBUTION

EXIT SIGN: DOUBLE FACE; WALL MOUNTED

EXIT SIGN: SINGLE FACE; CEILING MOUNTED

EXIT SIGN: DOUBLE FACE; CEILING MOUNTED

EXIT SIGN: SINGLE FACE; WALL MOUNTED

LIGHTING (REFER TO FIXTURE SCHEDULE FOR SYMBOLS)

FIXTURE IDENTIFICATION: (W-3) INDICATES FIXTURE TYPE ASSCHEDULED.

(W-3)

FIXTURE IDENTIFICATION, EMERGENCY WITH BATTERY PACK,AS INDICATED: (EX-X) INDICATES FIXTURE TYPE AS SCHEDULED.

(EX-X)

EM EMERGENCY.

NL NIGHT LIGHT: DO NOT SWITCH.

EGRESS DIRECTION ARROW (EXIT SIGNS).

LOW VOLTAGE LIGHTING TRANSFORMER.LV

VACANCY SENSOR, DUAL TECHNOLOGY, WALL.

VACANCY SENSOR, DUAL TECHNOLOGY,OMNI-DIRECTIONAL, CEILING.

LIGHTING CONTROL

OCCUPANCY SENSOR, DUAL TECHNOLOGY,OMNI-DIRECTIONAL, CEILING.

OCCUPANCY SENSOR, DUAL TECHNOLOGY, WALL.

OCCUPANCY SENSOR, DUAL TECHNOLOGY, DIRECTIONAL.

OCCUPANCY SENSOR, ULTRASONIC, OMNI-DIRECTIONAL,CEILING.U

PHOTOCELL.P

TWO-WAY EMERGENCY COMMUNICATION DEVICE PER IBC, WALL MOUNTED IN RECESSED BOX.

STRUCTURED CABLING

TELEPHONE, WALL MOUNTED ("X" INDICATES QUANTITY OFCABLES).

X

DATA CONNECTION: WIRELESS ACCESS POINT (WAP). REQUIRES (2) DATA DROPS PER DEVICE

TELEPHONE, WALL MOUNTED: WALL PHONE.W

OUTLET, DATA COMMUNICATION ("X" INDICATES QUANTITY OFCABLES).

X

OUTLET, BUILDING STANDARD COMBINATION TELEPHONE/ DATACOMMUNICATION.

TELEPHONE TERMINAL BOARD, FIRE TREATED PLYWOODPAINTED.

LAN RACK, FLOOR STANDING.

DATA CABLE, CATEGORY 5 (ONE-LINE DIAGRAM).D

VOICE CABLE, CATEGORY 3 (ONE-LINE DIAGRAM).V10

HIDDEN FEATURES LINE: HIDDEN, THIN LINE

NEW LINE: MEDIUM LINE.

CU-1 EQUIPMENT INDICATOR.

REVISION INDICATOR.1

KEYNOTE INDICATOR.1

ROOM IDENTIFIER WITH ROOM NAME AND NUMBER.ROOM NAME

100

DETAIL INDICATOR: A5 INDICATES DETAIL NUMBER, E-501INDICATES DRAWING SHEET WHERE DETAIL IS SHOWN.

A5

E-501

REFERENCE AND LINE SYMBOLS

MECHANICAL EQUIPMENT CONNECTION. REFER TO EQUIPMENT SCHEDULE FOR REQUIREMENTS.

JUNCTION BOX, CEILING.CJ

EARTH GROUND (ONE-LINE DIAGRAM).

JUNCTION BOX, SECURITY SYSTEM. PROVIDE CONDUIT AND ROUGH-IN PER SECURITY DRAWINGS.SEJ

JUNCTION BOX.J

ADA ACCESS PUSH PLATEHC

CONDUCTOR & CONDUIT ("CC") SCHEDULE INDICATOR. REFERTO ONE-LINE DIAGRAM.

1

LOW VOLTAGE WIRING: DIVIDE, MEDIUM LINE.

WIRING AND/OR RACEWAY: THIN LINE. WHERE "X" = :

CATV = CABLE TELEVISION NC = NURSE CALLCCTV = CLOSED CIRCUIT P = POWER

TELEVISION RC = RIGID CONDUITFA = FIRE ALARM S = SOUNDFO = FIBER OPTICS T = TELEPHONE

I = INTERCOM TV = TELEVISION

OTHERS AS NOTED IN OTHER SCHEDULES. RACEWAYS AND WIRING SHALL BE SIZED AS SHOWN AND/OR SPECIFIED.

X

BRANCH CIRCUIT HOME RUN TO PANELBOARD: NUMBER OFARROWS INDICATES NUMBER OF CIRCUITS. LETTER ANDNUMBER NOTATIONS IDENTIFY PANEL AND CIRCUIT NUMBERS.USE #12 CONDUCTORS, EXCEPT #10 CONDUCTORS SHALL BEINSTALLED IF DISTANCES EXCEED THOSE SPECIFIED IN THEELECTRICAL SPECIFICATIONS.

A-1,3,5

WIRING.

WIRING METHODS

CCTV

CCTV CABLE, POWER.P

CCTV CABLE, VIDEO SIGNAL.V

CCTV CCTV HEADEND EQUIPMENT.

CCTV MONITOR.M

CCTV CAMERA/ENCLOSURE WITH LENS, TYPICAL. SEE SCHEDULE.

CCTV CAMERA WITH PAN, TILT AND ZOOM.PTZ

PANNING CAMERA TRANSVERSE ANGLE.360°

MASTER STATION, INTERCOM.MSI

ANNUNCIATOR PANEL.AP

ULTRASONIC MOTION DETECTOR.U

PANIC DURESS SWITCH.P

PASSIVE INFRARED SENSOR.IR

DUAL TECHNOLOGY PASSIVE INFRARED SENSOR ANDULTRASONIC MOTION DETECTOR.

IRU

INTERCOM STATION.IC

CONTROLLED ACCESS POINT.CA

SENSOR, VOLUMETRIC.

SENSOR, GLASS BREAK.

SENSOR, BURIED VEHICULAR.

BUZZER, COMBINATION BELL.

BUZZER.

BELL.

REMOTE DOOR RELEASE BUTTON.RL

EXIT REQUEST.ER

DOOR SWITCH, BALANCED MAGNETIC CONTROL.

KEYPAD/CARD READER COMBINATION.KCR

CARD READER.CR

CARD ACCESS DOOR TYPE #1 OR AS NOTED. SEESCHEDULE.

#1

INTRUSION DETECTION HEADEND EQUIPMENT.SEC

SECURITY CONTROL PANEL.CTR

ACCESS CONTROL HEADEND EQUIPMENT.ACC

SECURITY CABLE. SEE EQUIPMENT SCHEDULE FOR CABLETYPE.

X

SECURITY

TERMINATOR, 75 OHM (TV DISTRIBUTION).

TV ANTENNA (ONE-LINE DIAGRAM).

SATELLITE ANTENNA.

TV OUTLET.

TV DISTRIBUTION

TV DISTRIBUTION CABLE, INDIVIDUAL DROPS.T

TV DISTRIBUTION CABLE, TRUNK.TR

COMBINER.CMB

DIRECTIONAL COUPLER.DC

DISTRIBUTION AMPLIFIER (ONE-LINE DIAGRAM).DA

SPLITTER (ONE-LINE DIAGRAM).SPL

SYMBOL DESCRIPTION

SYMBOLS LEGEND

1 10-17-17 ADDENDUM #1

C

SB

CORD REEL. SEE DETAIL

SPIDER BOX. SEE DETAIL C3 SHEET ES502.

1

1

1

Page 2: SYMBOLS LEGEND GSB - arnell-west.comarnell-west.com/wp-content/uploads/2017/10/Addendum-1-Drawings.pdf · es601 one-line diagram es602 panel schedules es603 equipment schedule es701

J

SB SB SB

SB

SB

J

"1HA"

"1LA"

(S3)

(S4)

(S2)

(S1)

SCOREBOARD

DAKTRONICS

MS-2002

1

2

1

1

1

(ZL-1D)

(ZL-1D)

(ZL-1D)

(ZL-1D)(ZL-1D)(ZL-1D)

(ZL-2)

(ZL-2)

(ZL-2)

(ZL-2)

(ZL-2)

(ZL-2)

(FP-1)(FP-1)

(FP-1)

FLAG

POLE

ES201

A1ES202

A1

(FL-1)

(FL-1)

(FL-1)

(FL-1)

1HA-5

33

1LA-17,19

1LA-18,20 1LA-21,23

H

H

H

H

H

H

4

4

4

4

4

4

556

6

5

"T1"

"MDSB"

"RMP XFMR"

7

8

8 8

7

1

1LA-22,241

1LA-25,27 1

1LA-26 1

1

1HA-61HA-8,10

1HA-12,14

9

9

10

10

1HA-13,15

1HA-17,19

LIGHTING

CONTACTOR1LA-291

375 WEST 200 SOUTHSALT LAKE CITY, UT

84101

801.521.8600801.521.7913

PF

www.gsbsarchitects.com

OWNER PROJECT NO.:GSBS PROJECT NO.:ISSUED DATE:

REVISIONS:

GSBARCHITEC

PLSPR201700272

Contsruction Ducuments

06/02/2017

2015.122.00

ES102

SITE ELECTRICAL PLAN -PHASE 1

City of South Jordan

Highland Park

Daybreak Village 8South Jordan, UT

10996 S. Redwood RoadSouth Jordan, UT 84095

SCALE: 1" = 30'-0"A1SITE ELECTRICAL PLAN - PHASE 1

1 NEW MUSCO LIGHT POLE, FIXTURES, AND BASE PROVIDED AND INSTALLED AS PART

OF THIS PROJECT. CIRCUIT BY ELECTRICAL CONTRACTOR.

2 NEW SCOREBOARD MANUFACTURED BY DAKTRONICS MS-2002. RUN 2 #10 CU THWN

+ #10 CU GND IN 3/4" CONDUIT FOR ELECTRICAL CIRCUIT.

3 ENTRY MONUMENT.

4 9" X 13" HAND HOLE FOR FUTURE SPORTS LIGHTING CIRCUIT.

5 1" CONDUIT WITH #200 NYLON PULL STRING TO PANEL 1HA OR IHB FOR FUTURE

SPORTS LIGHTING CIRCUIT.

6 1 1/2" CONDUIT WITH #200 NYLON PULL STRING TO PANEL 1HA OR IHB FOR FUTURE

SPORTS LIGHTING CIRCUIT.

7 REFER TO SPIDERBOX DETAIL ON SHEET ES502, DETAIL C3.

8 SPIDER BOX RECEPTACLE, MOUNTED IN LIGHT POLE BASE. REFER TO DETAILS C3,

ES502 AND A4, ES502.

9 RUN 2 #10 CU THWN AND #10 CU GND IN 3/4" CONDUIT.

10 RUN 2 #6 CU THWN AND #10 CU GND IN 1" CONDUIT.

SHEET KEYNOTES

1 10-17-17 ADDENDUM #1

1

1

Page 3: SYMBOLS LEGEND GSB - arnell-west.comarnell-west.com/wp-content/uploads/2017/10/Addendum-1-Drawings.pdf · es601 one-line diagram es602 panel schedules es603 equipment schedule es701

JJ

C C

CC

CONCESSIONS

103

WOMENS

RESTROOM

102

MECHANICAL

100

MENS

RESTROOM

101

WP

A

A

A

A

ICE

REFRIG

FREEZER

WP

WP

WPWP

1HA-1

1LA-3

1LA-1

1LA-2

1LA-4

1LA-5

1LA-6

1LA-7

1LA-8

1LA-9

1LA-10

(SA-1)

(SA-1)

(SA-1)(SA-1)

(SA-1)

(SA-1)

(FD-2)

(FD-2)

(FD-2)

(FD-2)

(FD-2)(FD-2)

(FD-2)

(FD-2)

(FD-2)

(SA-1)

(SA-1)

(OC-32) (OC-32)

(OC-32) (OC-32) (OC-32)

1HA-4

1LA-12

1LA-13

HAND DRYERHAND DRYER

A AA

1LA-14

1LA-15

(WH-1)1HA-7,9,11

TYP

1

TYP

1

TYP

1

EE

E

1

1 1

22

2

2

1

11

1

375 WEST 200 SOUTHSALT LAKE CITY, UT

84101

801.521.8600801.521.7913

PF

www.gsbsarchitects.com

OWNER PROJECT NO.:GSBS PROJECT NO.:ISSUED DATE:

REVISIONS:

GSBARCHITEC

PLSPR201700272

Contsruction Ducuments

06/02/2017

2015.122.00

ES201

PHASE 1 ENLARGEDELECTRICAL PLAN -CONCESSIONS ANDRESTROOM

City of South Jordan

Highland Park

Daybreak Village 8South Jordan, UT

10996 S. Redwood RoadSouth Jordan, UT 84095

SCALE: 1/2" = 1'-0"A1PHASE 1 ENLARGED ELECTRICAL PLAN - CONCESSIONS AND RESTROOM

1 EXTERIOR LIGHTING CONTROLLED BY PHOTOCELL

2 CORD REEL RECEPTACLE, REFER TO CORD REEL DETAIL D4 SHEET ES502.

SHEET KEYNOTES

1 10-17-17 ADDENDUM #1

1

Page 4: SYMBOLS LEGEND GSB - arnell-west.comarnell-west.com/wp-content/uploads/2017/10/Addendum-1-Drawings.pdf · es601 one-line diagram es602 panel schedules es603 equipment schedule es701

J

J

J

STORAGE

SHED

104

LARGE

PAVILION

105

WP

WP

WP

T

1HA-2

1HA-3

1LA-11

(ESA-1) (SA-1) (SA-1)

(SA-1)(SA-1)(SA-1)

(SA-1) (SA-1) (SA-1)

(ESA-1)(SA-1)(SA-1)

(FD-2)

(FD-2)

(FD-2)

(FD-2)

(FD-2) (FD-2) (FD-2)

(FD-2)(FD-2)

(FD-2)(FD-2)

(FD-2)(FD-2)

(FD-2)(FD-2)

(OC-32)

1LA-16

1

2

1

1

3

1

IRRIGATION

CONTROLLER

1LA-281

1

1

375 WEST 200 SOUTHSALT LAKE CITY, UT

84101

801.521.8600801.521.7913

PF

www.gsbsarchitects.com

OWNER PROJECT NO.:GSBS PROJECT NO.:ISSUED DATE:

REVISIONS:

GSBARCHITEC

PLSPR201700272

Contsruction Ducuments

06/02/2017

2015.122.00

ES202

PHASE 1 ENLARGEDELECTRICAL PLAN -PAVILION AND STORAGESHED

City of South Jordan

Highland Park

Daybreak Village 8South Jordan, UT

10996 S. Redwood RoadSouth Jordan, UT 84095

SCALE: 1/2" = 1'-0"A1PHASE 1 ENLARGED ELECTRICAL PLAN - PAVILION AND STORAGE SHED

1 60 MINUTE TWIST TIMER FOR CONTROL OF LIGHT FIXTURE FD-2.

2 3/4" CONDUIT AND #200 NYLON PULL STRING WITH J-BOX FOR DOOR CONTROL./

SWITCH / CONDUCTORS PROVIDED AND INSTALLED BY OTHERS.

3 EXTERIOR LIGHTING CONTROLLED BY PHOTOCELL

SHEET KEYNOTES

1 10-17-17 ADDENDUM #1

1

Page 5: SYMBOLS LEGEND GSB - arnell-west.comarnell-west.com/wp-content/uploads/2017/10/Addendum-1-Drawings.pdf · es601 one-line diagram es602 panel schedules es603 equipment schedule es701

J

J

LargePavilion

106MECHANICAL

108

MensRestroom

107

WomensRestroom

109

WP

WP

WP

1HB-1

1LB-1

1LB-2

WP

1LB-3

1LB-4HAND

DRYER

HAND DRYER

(SA-1)

(OC-32)

(SA-1)

(FD-2) (FD-2) (FD-2)

(FD-2)

(FD-2)

(FD-2)

(FD-2)(FD-2)(FD-2)

(FD-2)

(FD-2)

(FD-2) (FD-2)

(FD-2)(FD-2)

(FD-2)(FD-2)

(FD-2)

(FD-2) (FD-2)(FD-2)

(OC-32)

(OC-32)

(OC-32)

(OC-32)

1HB-2

(WH-2)1HB-4,6,8

TYP

1 1

TYP

1

1

E

E1

1

TYP

1

1

T2

1

375 WEST 200 SOUTHSALT LAKE CITY, UT

84101

801.521.8600801.521.7913

PF

www.gsbsarchitects.com

OWNER PROJECT NO.:GSBS PROJECT NO.:ISSUED DATE:

REVISIONS:

GSBARCHITEC

PLSPR201700272

Contsruction Ducuments

06/02/2017

2015.122.00

ES203

PHASE 2 ENLARGEDELECTRICAL PLAN -PAVILION AND RESTROOM

City of South Jordan

Highland Park

Daybreak Village 8South Jordan, UT

10996 S. Redwood RoadSouth Jordan, UT 84095

SCALE: 1/2" = 1'-0"A1PHASE 2 ENLARGED ELECTRICAL PLAN - PAVILION AND RESTROOM

1 EXTERIOR LIGHTING CONTROLLED BY PHOTOCELL

2 60 MINUTE TWIST TIMER FOR CONTROL OF LIGHT FIXTURE FD-2.

SHEET KEYNOTES

1 10-17-17 ADDENDUM #1

1

Page 6: SYMBOLS LEGEND GSB - arnell-west.comarnell-west.com/wp-content/uploads/2017/10/Addendum-1-Drawings.pdf · es601 one-line diagram es602 panel schedules es603 equipment schedule es701

LIGHTING FIXTURE SCHEDULENOTE TO BIDDERS: COMPLY WITH THE SPECIFICATIONS.

REFER TO SPECIFICATIONS FOR IMPORTANT TECHNICAL REQUIREMENTS FOR LIGHTING FIXTURES, BALLASTS, AND LAMPS. THE CATALOG NUMBERS LISTED

BELOW HAVE BEEN CAREFULLY PREPARED TO ASSIST BIDDERS IN SELECTING PRODUCTS TO ACHIEVE THE DESIGN CONCEPT, HOWEVER, PRIOR TO BIDDING,

EACH MANUFACTURER SHALL COMPARE THE CATALOG NUMBERS SHOWN WITH THE DESCRIPTION AND REQUIREMENTS ON THE DRAWINGS, AND SHALL

NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES. SPECIFICALLY INCLUDED IN THIS EVALUATION SHALL BE THE VERIFYING OF PROPER MOUNTING

KITS OR ACCESSORIES TO FACILITATE INSTALLATION AS SHOWN AT EACH LOCATION ON THE DRAWINGS. NO ALLOWANCE OR REDRESS WILL BE ALLOWED

FOR DISCREPANCIES THAT WERE NOT REPORTED TO THE ARCHITECT/ENGINEER IN TIME FOR CORRECTION OR CLARIFICATION BEFORE THE BID. THE

REPORTING OF ANY AMBIGUITY IS THE RESPONSIBILITY OF THE BIDDER. PROVIDE UNIT PRICES AND FIXTURE BRAND SELECTED FOR ADD/DELETE CHANGES

FOR EACH FIXTURE TYPES SHOWN WITHIN 48 BUSINESS HOURS OF THE BID DATE. FAILURE TO COMPLY WITH THIS REQUIREMENT MAY DISQUALIFY THE

PRODUCTS AND EMPOWER THE ENGINEER TO DETERMINE FAIR VALUE FOR FIXTURE AND INSTALLATION CHANGES, WITHOUT FURTHER INPUT FROM THE

CONTRACTOR OR INSTALLER. SUBMITTAL PACKAGE SHALL INCLUDE LAMP MANUFACTURER AND CATALOG NUMBER ON EACH FIXTURE SHEET. ON ALL

PENDANT MOUNTED FIXTURES, PROVIDE A SECOND SET OF PENDANTS, OF A DIFFERENT LENGTH, AS DIRECTED BY THE ARCHITECT/ENGINEER, PROVIDED

AND INSTALLED AT NO ADDITIONAL CHARGE. ALL FIXTURES SHALL BE APPROVED BY UL OR ANOTHER ACCEPTABLE TESTING LAB FOR THE PURPOSE

INTENDED AND WITH THE LAMP AND BALLAST PROPOSED. CONTRACTOR ALLOWANCE PRICES ARE ACCURATE WHEN THIS JOB WAS SPECIFIED,

CONTRACTOR AND ELECTRICAL DISTRIBUTOR SHALL VERIFY THIS ALLOWANCE AND REPORT ANY PROBLEMS TO THE ENGINEER BEFORE THE BID.

ALLOWANCE PRICE MAY OR MAY NOT INCLUDE LAMP(S) OR FREIGHT AS NOTED, AND DO NOT INCLUDE ANY TAXES. UNIVERSAL VOLTAGE (120/277)

BALLASTS REQUIRED UNLESS NOTED OTHERWISE. DIMENSION SEQUENCE = (LENGTH X WIDTH X DEPTH) IN INCHES.

SYMBOL MARK

E

E

DL-1

DL-1

E1

E-1

E-2

SA

SA-1

FD

FD-2

FP

FP-1

FP

FP-1

FL-1

OC-1

ZL

ZL-1D

ZL-2

FIXTURE CHARACTERISTICS

BODY / AIR / MOUNTING / DOOR

LENS/LOUVER/REFLECTOR/OTHER

E PREFIX INDICATES THAT FIXTURE IS PROVIDED WITH AN EMERGENCY BATTERY PACK TO PROVIDE POWER TO ANY 2, 3,

4 OR 8 FOOT FLOURESCENT LAMP COMPATIBLE WITH ALL STANDARD AND ELECTRONIC BALLASTS; COMPLETELY SELF-CONTAINED

TO PROVIDE 90 MINUTES OF EMERGENCY POWER TO FIXTURE BALLAST; MINIMUM LIGHT OUTPUT FOR TYPICAL 4' LAMP SHALL

BE 1100 LUMENS OR HIGHER;UNIVERSAL TRANSFORMER FOR 120 OR 277 VOLTS; LOW VOLTAGE PROTECTION, COMBINATION

TEST SWITCH AND AC "ON" INDICATOR; 10 YEAR PRO-RATA WARRANTY; INSTALL TEST SWITCH IN A MANNER THAT REQUIRES

NO DISASSEMBLY FOR TESTING.

EMERGENCY BATTERY PACK.

LED DOWNLIGHT; THERMALLY PROTECTED HOUSING: TO ACCOMMODATE MULTIPLE TRIMS AND REFLECTOR ASSEMBLIES

FOR LAMPS AS LISTED BELOW; LOW IRIDESCENT REFLECTOR FINISH (EVEN IF NOT SHOWN IN CATALOG

#); SELF FLANGING TRIM UNLESS NOTED.

6" RECESSED DOWNLIGHT

4000K HIGH ABUSE

EXIT SIGN: THERMOPLASTIC HOUSING; CEILING MOUNT, SEE DRAWINGS; ARROWS PER PLANS; LED LAMPS;EMERGENCY BATTERY PACK

WITH 10 YEAR PRO-RATA WARRANTY; SELF-TESTING; DIFUSE LEN PANEL; GREEN LETTERS ON WHITE BACKGROUND.

MUST MEET NFPA ILLUMINATION STANDARDS. UNITS SHOWN ARE CEILING MOUNT MODELS.

SINGLE FACE:

DUAL FACE:

GENERAL PURPOSE INDUSTRIAL: WHITE ENAMEL; AIRCRAFT CABLING MOUNTING

4', LED.

WALL OR CEILING HIGH ABUSE LINEAR

HIGH ABUSE LINEAR FIXTURE

12" WIDE

INGROUND FLOOD LIGHT, DIE-CAST BRASS, ROCK GUARD, TRIM RING, LED; INSTALL IN CONCRETE PER MANUFACTURER'S

RECOMMENDATIONS; CONTROL BY PHOTOCELL.

6", SPOT FLOOD, LED 5100K

INGROUND FLOOD LIGHT, DIE-CAST BRASS, ROCK GUARD, TRIM RING, LED; INSTALL IN CONCRETE PER MANUFACTURER'S

RECOMMENDATIONS; CONTROL BY PHOTOCELL.

6", SPOT FLOOD, LED 5100K

6", FLOOD, LED 4000K

EXTERIOR TRAPEZOID

LIGHT POLES: TOTALLY ENCLOSED RAINTIGHT, DUST-TIGHT AND CORROSION RESISTANT; POLE AS SHOWN IN DETAIL WITH

HANDHOLE, COVER, BOLT COVER, AND BASE; PAINTED (COLOR TO BE SELECTED BY ARCHITECT / ENGINEER WHICH MAY

DIFFER FROM CATALOG NUMBER SHOWN). MTB= 120,208,240,277 VOLT MULTI-TAP BALLAST. ALL BALLASTS HPF. ARM MOUNT.

HORIZONTAL LAMP, SEGMENTED OPTICS.

FULL CUTOFF

LUMINAIRE DOUBLE HEAD,

TYPE III DISTRIBUTION, LED.

30' POLE

FULL CUTOFF

LUMINAIRE SINGLE HEAD,

TYPE III DISTRIBUTION, LED.

15' POLE

LAMP

LED

LED

LED

LED

LED

LED

LED

LED

LED

LED

LED

WATTS

120/277V

26W

1W

2W

42W

45W

11W

11W

36W

47W

232W

116W

VOLTS

3W

120/277V

120/277V

120/277V

277/120V

277/120V

277/120V

277/120V

277/120V

277/120V

277/120V

277/120V

MANUFACTURER

IOTA

BODINE

LITHONIA

PRESCOLITE

HUBBELL

CHLORIDE

LIGHTOLIER

SIDELITE

EMERGE

KENALL

MCPHILBEN

DUAL-LITE

LSI

EELP

LITHONIA

SURE-LITES

DAY-BRITE

CHLORIDE

LIGHTOLIER

CHLORIDE

EVENLITE

DUAL-LITE

EELP

LITHONIA

LSI

SURE-LITES

DAY-BRITE

CHLORIDE

LIGHTOLIER

MCPHILBEN

CHLORIDE

EVENLITE

LITHONIA

LSI

COOPER

PHILIPS

H. E. WILLIAMS

KENALL

KIM

FC LIGHTING

HYDREL

LUMIERE

LUMASCAPE

FC LIGHTING

KIM

FC LIGHTING

HYDREL

LUMIERE

LUMASCAPE

FC LIGHTING

INSIGHT

STONCO

FC LIGHTING

LIGMAN

LITHONIA

EATON

LSI

SPAULDING

NORIBACHI

LITHONIA

CREE

MCGRAW

BEACON

VISIONAIRE

LITHONIA

CREE

MCGRAW

BEACON

VISIONAIRE

CATALOG NUMBER

I-80

B50

PS-1400

EFPS-5

E96

CFP841

FBP50

S60F

FPDL-U

HRDL6ICL-26L30K-DV-DCC-FW-CSS-G

CXXL-1-GW

LXSGWE

EX-G-U-WB-WH

XE 1 GW EM

LQM S W 1 G 120/277 ELN

LPX70DGW

CXL-1-GW-EM

SLN1GW

LTN1GW

VEGWEM

TLX EM GU W

LXUGWE

XE 2 GW EM

LQM S W 3 G 120/277 ELN

EX-G-U-WB-WH

LPX70DGW

CXL-3-GW-EM

SLN2GW

LTN2GW

CXXL-3-GW

VU6LSD

TLX EM GU W

ZL1D L48 5000LM FST MVOLT 40K 80CRI WH

SDL-4-LED-HO-NW-UE

4SNLED-LD4-53SL-LN-UNV-L8XX-CD1-U

LF4FR52H40UDZT

LLM-4-L52/840-S-RD-DIM-UNV

MLHA12-48-F-MW-PP-45L40K-DCC-1-DV

LTV768WB/9L5KUV/RG60/TR60

FCD609R-UNV-LED3K-SP

PDX7 B 12LED WHT53K MVOLT NSP FLC 34S RG

3002N-RD-18LED40000-MFL-CLR-UNV-SCBA 3000-RG

LS363LED-15W4-A-M-85-XX-23-Q-09

FCD609R-UNV-LED3K-SP

LTV768WB/9L5KUV/RG60/TR60

FCD609R-UNV-LED3K-SP

PDX7 B 12LED WHT53K MVOLT NSP FLC 34S RG

3002N-RD-18LED40000-MFL-CLR-UNV-SCBA 3000-RG

LS363LED-15W4-A-M-85-XX-23-Q-09

FCD609R-UNV-LED3K-SP

MQ2/30/40K/45/TR

LPF2-E-4K-FL-K-F1-8-SCBA

FCW5806-UNV-LED4K-SCBA-NFL

UCE-50591-30W-M-W40-277V-SCBA

WST LED 2 10A700/50K SR3 MVOLT PE XXXXX

IST-E01-LED-E1-BL3-SCBA-7050

XGBWM3-WT-LED-28-450-CW-UE-CBA-PCXXX

TRP-30L5K-053-3-U-SCBA-PC

HEX-042-A-NW-MT WPJ

DSX2-LED-100C-700-50K-T3M-MVOLT-HS

ARE-EDG-3M-DA-10-UL-SCBA-525MA

GLEON-AE-06-LED-E1-T3-SCBA

VP-L-96NB-280-5K-T3-UNV-HSS*-RA-SCBA

VLX-1-T3-96LC-7-4K-UNV-AM-SCBA

DSX2-LED-100C-350-50K-T3M-MVOLT-HS

ARE-EDG-3M-DA-5-UL-SCBA-525MA

GLEON-AE-03-LED-E1-T3-SCBA

VP-L-96NB-140-5K-T3-UNV-HSS*-RA-SCBA

VLX-1-T3-47LC-7-4K-UNV-AM-SCBA

NOTES

3'-0"

3"

CLR

6'-0"

2"

CLR

30'-0"

+/- .75" GROUT BED UNDERLIGHT POLE BASE

ANCHOR BOLTS AND FULL BASE COVER PER LIGHT POLE MANUFACTURER. SEE LIGHT POLE MANUFACTURER TEMPLATE TO SET ANCHOR BOLTS

INTERIOR PAINTED WITH RUST INHIBITIVE PRIMER

PROVIDE IN-LINE FUSE WITHINSULATED FUSE HOLDER HERE

HAND HOLE COVER

ROUND STEEL POLEPAINTED TO MATCH FIXTURE

SEE FIXTURE SCHEDULE FORFIXTURE HEAD REQUIREMENTS

.75" CHAMFER ALL EXPOSED EDGES

2 SETS #4 TIES IN TOP 5" OF BASE

4 SETS #4 TIES AT 12" OC

#6 .75" CONDUIT

CONDUIT (TYPICAL)

8 #6 BARS VERTICAL WITH 3SETS #4 TIES AT 18" OCEXCEPT AS NOTED ABOVE

24"Ø CONCRETE BASE

8' X .75" COPPERWELD GROUND ROD

1

1

C

S1

S2

S3

-

1 CON

2 CON

3 CON

SK

10 POLE LIGHTING

CONTACTOR ELECTRICALLY

OPERATED/HELD, 120V COIL,

NEMA 3R ENCLOSURE,

MANUFACTURED BY SQUARE

D OR EQUAL. LABEL

"EXTERIOR LIGHTING

CONTACTOR"

1LA-29

S4

4 CON

SPARE

SPARE

3'-0"

3'-0"

CARLON WEATHERPROOF COVER E1212C24 WITH NEMA L14-50 RECEPTACLE

24"Ø CONCRETE BASE

1'-0"

1'-0"

3000 PSI CONCRETE FOOTING

UNDISTURBED EARTH

1/2" DIA. CONDUIT

3/4" CHAMFER TYPICAL

TENNON/ SLIPFITTER

FLOOD LIGHT

0'-6"

EQ EQ

BOTTOM OF CEILING

RIGIDLY SUPPORTED TOPREVENT MOVEMENT.COORDINATE WITHARCHITECTURAL /STRUCTURAL DRAWINGS.

CORD REEL

TYPE SO CORDWITH 25' OF CORD

TWIST LOCK PLUGAND CONNECTOR

TYPE SO CORD(SIZE AS SHOWN) 3WIRE 1 CIRCUITCORD.

36" AFF

CONDUIT (SIZE ASSHOWN) RIGIDLYSUPPORTED TO PREVENTMOVEMENT

OUTLET BOX WITHTWIST-LOCKRECEPTACLE

36"

AF

F

OUTLET BOX WITH 2 DUPLEX.EACH SERVED WITH TWO 20AMP CIRCUITS. DANIELWOODHEAD 3000 SERIES WITHINSULATED/ISOLATED GROUND.

1 DUPLEX1 DUPLEX

375 WEST 200 SOUTHSALT LAKE CITY, UT

84101

801.521.8600801.521.7913

PF

www.gsbsarchitects.com

OWNER PROJECT NO.:GSBS PROJECT NO.:ISSUED DATE:

REVISIONS:

GSBARCHITEC

PLSPR201700272

Contsruction Ducuments

06/02/2017

2015.122.00

ES502

SITE ELECTRICAL DETAILS

City of South Jordan

Highland Park

Daybreak Village 8South Jordan, UT

10996 S. Redwood RoadSouth Jordan, UT 84095

SCALE: NTS

PARKING LOT LIGHT POLEBASE DETAIL

A4SCALE: NTS

SPORTS FIELD LIGHTINGCONTROL

A3

SCALE: NTS

SPIDER BOX RECEPTACLEDETAIL

C3 SCALE: NTS

GROUND MOUNTED FLOODDETAIL

C4

SCALE: NTS

CORD REEL DETAILD4

1 10-17-17 ADDENDUM #1

1

1

1

Page 7: SYMBOLS LEGEND GSB - arnell-west.comarnell-west.com/wp-content/uploads/2017/10/Addendum-1-Drawings.pdf · es601 one-line diagram es602 panel schedules es603 equipment schedule es701

**IG

(E.G.)

SBJIG/HHGSIZEQTY

CONDUCTOR(NOTE 1)NOTES

*

SYM AMP

COPPER CONDUCTOR AND

SUBSCRIPT (NOTE 5)

SCHEDULE NUMBER

5

CONDUIT SIZE

CONDUIT SCHEDULE

NO SCALE

GENERAL SHEET NOTES1. PROVIDE NEMA 3R ENCLOSURES FOR EQUIPMENT LOCATED OUTDOORS.

REFER TO PLANS FOR EQUIPMENT LOCATIONS.

2. REFER TO PLANS FOR CONSTRAINTS ON PHYSICAL DIMENSIONS AND

CLEARANCE REQUIREMENTS OF EQUIPMENT. PROVIDE EQUIPMENT

DIMENSIONS THAT FALL WITHIN THE CONSTRAINTS OF EACH SPECIFIC

LOCATION.

3. ALL EQUIPMENT SHALL BE CONSTRUCTED AND BRACED FOR THE SEISMIC

CONDITIONS OF THE PROJECT. REFER TO ELECTRICAL SPECIFICATIONS FOR

REQUIREMENTS.

4. PROVIDE PERFORMANCE TESTING FOR GROUND-FAULT PROTECTION

SYSTEMS ON SITE WITH A WRITTEN RECORD OF THIS TEST SUBMITTED TO THE

AUTHORITY HAVING JURISDICTION PER 2011 NEC 230.95(C).

SHEET KEYNOTES1. -

1 20 .75 2 12 12 12 8 2

2 20 .75 3 12 12 12 8 2,3

3 20 .75 4 12 12 12 8 2,3

4 30 .75 2 10 10 10 8 2

5 30 .75 3 10 10 10 8 2

6 30 .75 4 10 10 10 8 2

7 40 1 2 8 10 8 6 2

8 40 1 3 8 10 8 6 2

9 40 1 4 8 10 8 6 2

10 55 1 2 6 10 8 4 2

11 55 1 3 6 10 8 4 2

12 55 1.25 4 6 10 8 4 2

13 70 1 2 4 8 4 2 2

14 70 1.25 3 4 8 4 2 2

15 70 1.25 4 4 8 4 2 2

16 85 1.25 2 3 8 3 2 2

17 85 1.25 3 3 8 3 2 2

18 85 1.25 4 3 8 3 2 2

19 95 1.25 3 2 8 2 2 2

20 95 1.50 4 2 8 2 2 2

21 130 1.50 3 1 6 2 2 2

22 130 1.50 4 1 6 2 2 2

23 150 2 3 1/0 6 2 1/0 2

24 150 2 4 1/0 6 2 1/0 2

25 175 2 3 2/0 6 2 2/0 2

26 175 2 4 2/0 6 2 2/0 2

27 200 2 3 3/0 6 2 2/0 2

28 200 2.50 4 3/0 6 2 2/0 2

29 230 2.50 3 4/0 4 2 2/0 2

30 230 2.50 4 4/0 4 2 2/0 2

31 255 2.50 3 250 4 1 2/0 2

32 255 2.50 4 250 4 1 2/0 2

33 310 3 3 350 3 1/0 3/0 2

34 310 3 4 350 3 1/0 3/0 2

35 380 3.50 3 500 3 3/0 3/0 2

36 380 4 4 500 3 3/0 3/0 2

37 400 2 EA 2 3 3/0 3 3/0 3/0 2

38 400 2 EA 2.50 4 3/0 3 3/0 3/0 2

39 510 2 EA 2.50 3 250 1 4/0 3/0 2

40 510 2 EA 3 4 250 1 4/0 3/0 2

41 620 2 EA 3 3 350 1/0 4/0 3/0 2,4

42 620 2 EA 3 4 350 1/0 4/0 3/0 2,4

43 760 2 EA 3.50 3 500 1/0 4/0 3/0 2,4

44 760 2 EA 4 4 500 1/0 4/0 3/0 2,4

45 855 3 EA 3 3 300 2/0 4/0 3/0 2,4

46 855 3 EA 3 4 300 2/0 4/0 3/0 2,4

47 1000 3 EA 3.50 3 400 2/0 4/0 3/0 4

48 1000 3 EA 3.50 4 400 2/0 4/0 3/0 4

49 1140 3 EA 4 3 500 3/0 4/0 3/0 4

50 1140 3 EA 4 4 500 3/0 4/0 3/0 4

51 1240 4 EA 3 3 350 3/0 4/0 3/0 4

52 1240 4 EA 3 4 350 3/0 4/0 3/0 4

53 1675 5 EA 4 4 400 4/0 4/0 4/0 4

54 2010 6 EA 4 4 400 250 250 250 4

55 2660 7 EA 4 4 500 350 350 350 4

56 3040 8 EA 4 4 500 500 500 500 4

57 4180 11 EA 4 4 500 500 500 500 4

58 5 EA 4 6

59 5 6

60 10 EA 4 6

CONDUCTOR AND CONDUIT SCHEDULE NOTES

1. CONDUCTORS SHOWN ARE SHOWN FOR EACH CONDUIT WITH

MODIFICATIONS AS NOTED IN NOTE 5. ALL CONDUCTORS SHOWN ARE

THWN UNLESS OTHERWISE NOTED.

2. PROVIDE EQUIPMENT GROUND CONDUCTORS PER TABLE 250-122

WHEN CIRCUIT BREAKERS ARE SIZED GREATER THAN AMPERE RATING

SHOWN IN TABLE.

3. PROVIDE #10 NEUTRALS FOR MULTIWIRE BRANCH CIRCUITS SERVING

COMPUTERS.

4. GROUND CONDUCTOR SHALL BE OMITTED BETWEEN THE UTILITY

TRANSFORMER AND THE FIRST OVERCURRENT PROTECTIVE DEVICE.

5. SYMBOL SUBSCRIPTS:

"2N": INCLUDE TWO NEUTRAL CONDUCTORS, SIZED AS SCHEDULED

FOR PHASED AND NEUTRAL CONDUCTORS.

"FG": FULL SIZE GROUND, SIZE EQUIPMENT GROUNDING

CONDUCTOR TO BE THE SAME SIZE AS THE PHASE CONDUCTORS.

"HH": NEUTRAL CURRENTS EXIST DUE TO HIGH HARMONIC

"NONLINEAR" LOADS. CURRENT CARRYING CONDUCTORS DERATED

ACCORDINGLY. PROVIDE THE IG/HH SIZE FOR THE EQUIPMENT

GROUNDING CONDUCTOR.

"IG": INCLUDE IG (INSULATED/ISOLATED GROUND CONDUCTOR)

SCHEDULED ALONG WITH GROUND OF EQUIPMENT GROUND

CONDUCTOR.

"SBJ": SUBSTITUTE "SBJ" CONDUCTOR FOR "G" CONDUCTOR

SHOWN, WHICH IS SIZED FOR THE SYSTEM BONDING JUMPER OF

THE SEPARATELY DERIVED SYSTEM.

6. RACEWAY ONLY. CONDUCTORS PROVIDED BY UTILITY.

A3ONE-LINE DIAGRAM

FAULT CURRENT TABLEBUSMDSB

1HA

1HB

1LA

PROVIDE FULLY RATED CIRCUIT BREAKERS IN PANELBOARDS FOR THE

FAULT CURRENT SHOWN. SERIES RATINGS WITH NEXT LEVEL UPSTREAM

OVERCURRENT PROTECTIVE DEVICES ARE PERMITTED SUBJECT TO

FACTORY UL DOCUMENTATION OF SERIES RATING SUBMITTED TO ENGINEER.

IF DEVICE OR EQUIPMENT FAULT CURRENT RATING IS NOT SHOWN,

ASSUME 100,000 AIC.

FAULT CURRENT65,000 SCA

22,000 SCA

22,000 SCA

10,000 SCA

1LB 10,000 SCA

MAIN DISTRIBUTION SWITCHBOARD "MDSB"600A, 480/277V 3Ø, 4W, 65,000 AIC

600/3

250/3 250/3 90/3

GROUNDPER NEC

42

NEW

RMP

TRANSFORMER

32

250/3

"1HB"

PHASE 2

32

250/3

"1HA"

PHASE 1

T-175kVA

480-208Y/120V

3∅, 4W

DELTA/ WYE, K-1 RATEDDRY TYPE TRANSFORMER3.4% Z

19

30

225/3

"1LA"

PHASE 1

30

225/3

"1LB"

PHASE 1

42

M

600/3600/3 CT

ENCLOSURE

1

1

1

1

1

1

375 WEST 200 SOUTHSALT LAKE CITY, UT

84101

801.521.8600801.521.7913

PF

www.gsbsarchitects.com

OWNER PROJECT NO.:GSBS PROJECT NO.:ISSUED DATE:

REVISIONS:

GSBARCHITEC

PLSPR201700272

Contsruction Ducuments

06/02/2017

2015.122.00

ES601

ONE-LINE DIAGRAM

City of South Jordan

Highland Park

Daybreak Village 8South Jordan, UT

10996 S. Redwood RoadSouth Jordan, UT 84095

1 10-17-17 ADDENDUM #1

1