Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
611800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
TW Series — 22mm NEMA Style Pushbuttons
Key features:
• TWNEMAStyleSwitcheswithsnap-oncontacts• Corrosionresistantoctagonalchromeplatedlockingbezel• Snap-on10Acontactblocks• IncandescentorLEDillumination• Slowmake,doublebreak,selfcleaningcontacts• Modularconstructionformaximumflexibility• NEMA4XandIP65watertight/oiltightpanel• Availableassembledorassub-components• LargeM3.5screwterminalswithcaptivesemsplate
IDEChasyour22mmswitchingneedscovered.
Buttonstylesincludeflush,extended,mushroom,orsquareandallbodiesarecraftedfromfracture-resistantnylon.
Allilluminatedunitsfeaturetwolensestyles,onethatmaximizeslightdisper-sion,theotheraccommodatesdirectlensengraving.
Selfcleaningcontactmechanismsallowforawidecurrentrating,5mAto10A,whichreducestheneedforvariouscontactmaterials.
Whenlookingfora22mmswitchthatisdurable,easytouse,andversatile,thenIDEC’sTWseriesisyoursolution.
ULListedFileNo.E68961
CSAApprovedFileNo.LR21451 FileNo.DK95-01696
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
612 www.IDEC.com
Spec
ifica
tions
Conforming to Standards EN60947-1,EN60947-5-1,VDE0660-200,UL508,CSAC22-2No.14
Approvals
FileNo.E68961
®
FileNo.LR21451 CertificateNo.2030010305027380
RegistrationNo:J9551802(E-Stops)RegistrationNo:J9551803(Allotherswitches)RegistrationNo:J9551804(PilotLights)
CSA:pushbuttonsandselectorswitches:A600pilotlightsandilluminatedpushbuttons,directsupplypilotlightsandilluminatedpushbuttonswithintegraltransformer(100/110,115,120,200/220,230,240,380,400/440,480V)UL: pushbuttonsandselectorswitches:A600pilotlightsandilluminatedpushbuttons,directsupplypilotlightsandilluminatedpushbuttonswithintegraltransformer(100/110,115,120,200/220,230,240,380,400/440,480V)TÜV:pushbuttonsandselectorswitches:A600=P600(NO,NC)/Q600(NO-EM,NC-LB)pilotlightsandillumi-natedpushbuttons,directsupplypilotlightsandilluminatedpushbuttonswithintegraltransformer(100/110,115,120,200/220,230,240,380,400/440,480V)
Operating Temperature Operation:–25to+50°C(withoutfreezing),Storage:–40to+80°C(withoutfreezing)
Vibration Resistance 5to55Hz,100m/sec2(10g)conformingtoIEC6068-2-6
Shock Resistance 1000m/sec2(100g)conformingtoIEC6068-2-7
Electric Shock Protection Class0conformingtoIEC60536
Degree of Protection (conforming to IEC60529) (conforming to NEMA ICS6-110)
IP65fromfrontofthepanel;(IP54forkeyswitches)IP20(TypeHW-Fcontactblock)Type1,2,3,3R,3S,4,4X,5,12,13(Type1,2,3R,5,12,13forkeyswitches)
Mechanical Life Momentarypushbuttons:5,000,000(900operationsperhour)Allotherswitches:500,000
Pollution Degree (conforming to IEC60947-1) 3forswitchesnotusingatransformer,2forswitchesusingatransformer
Rated Operational CharacteristicsAC-15:A600orUe=250V,le=3A(NO,NC,NO-EM,NC-LB)DC-13:P600orUe=125V,le=1.1A(NO,NC)DC-13:Q600orUe=125V,le=0.9A(NO-EM,NC-LB)
Rated Insulation Voltage 600V
Rated Switching Over-Voltage Lessthan4kV,conformingtoIEC60947-1
Rated Impulse Withstanding Voltage 4kVforcontactcircuit,2.5kVforlampcircuit
Rated Thermal Current 10Amp
Minimum Switching Capacity 5mAat3VAC/DC
Contact Operation SlowbreakNCorslowmakeNO,self-cleaning
Recommended Terminal Torque 0.8Nm(7.1inlb.)
External Short-Circuit Protection 10A250VfuseconformingtoIEC60269-1
Applicable Wire Size Minimum1x22AWG,max.2x14AWGor1x12AWG
Contact Resistance Initialcontactresistanceof50mΩorless
Contact Gap 4mm(NOandNC),2mm(NO-EMandNC-LB)
Electrical Reliability MTBF<1faultfor10millionoperationcycles(3VDC,5mA)
Lamp Ratings Incandescent:1WLEDs:6V:17mAmax,12/24V:11mAmax,120/240V:10mAmax
Horsepower Rating 1/4HP@120V(single-phase,non-reversingmotor);1HP@240V(3phase,non-reversingmotor)
Maximum Inrush Current 40A(40ms)
Contact Material Silver
Cont
act R
atin
gs PushbuttonsIlluminated PushbuttonsSelector SwitchesIlluminated Selector SwitchesPushbutton Selectors
ContactBlock TypeHW-C/HW-F
RatedInsulationVoltage 600V
RatedContinuousCurrent 10A
ContactRatingsbyUtilizationCategoryIEC60947-5-1
AC-15(A600)DC-13(P600)
Char
acte
ristic
s
Contact Ratings by Utilization Category
OperationalVoltage 24V 48V 50V 110V 220V 440V
OperationalCurrent
AC50/60HzAC-12Controlofresistiveloadsandsolidstateloads 10A — 10A 10A 6A 2A
AC-15Controlofelectromagneticloads(>72VA) 10A — 7A 5A 3A 1A
DCDC-12Controlofresistiveloadsandsolidstateloads 8A 5A — 2.2A 1.1A —
DC-13Controlofelectromagnets 5A 2A — 1.1A 0.6A —
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
613800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Non-Illuminated Pushbuttons (Assembled)
Assembled Pushbuttons
A B ( ) W 1 10 ( ) – B
Function
B: MomentaryO: MaintainedK: KeyOn/OffLock
Bezel Shape
Blank:OctagonalF: FullShroudG: MushroomShroudQ: Square
Button Color
B: Black G: Green W:WhiteR: Red S: Blue Y: Yellow
Terminal Style
Blank:StandardN:Fingersafe(IP20)
Contact Arrangement
10:1NO 01:1NC20:2NO 02:2NC11:1NO-1NC 22:2NO-2NC
Button Shape
1: Flush2: Extended3: MushroomHeadØ29mm4: MushroomHeadØ40mm
Series Designation
W:TWSeries
Tobeusedforinterpretingpartnumbersonly,notforpartnumberdevelopment.
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
614 www.IDEC.com
Non-Illuminated Pushbuttons (Assembled) continued
Non-Illuminated PushbuttonsStyle Contacts Momentary Action Maintained Action
Flush
1NO1NC1NO-1NC2NO2NC
ABW110-jABW101-jABW111-jABW120-jABW102-j
AOW110-jAOW101-jAOW111-jAOW120-jAOW102-j
Extended
1NO1NC1NO-1NC2NO2NC
ABW210-jABW201-jABW211-jABW220-jABW202-j
AOW210-jAOW201-jAOW211-jAOW220-jAOW202-j
Recessed
1NO1NC1NO-1NC2NO2NC
ABFW110-jABFW101-jABFW111-jABFW120-jABFW102-j
AOFW110-jAOFW101-jAOFW111-jAOFW120-jAOFW102-j
ExtendedwithFullShroud
1NO1NC1NO-1NC2NO2NC
ABFW210-jABFW201-jABFW211-jABFW220-jABFW202-j
AOFW210-jAOFW201-jAOFW211-jAOFW220-jAOFW202-j
Ø29mmMushroomHead
1NO1NC1NO-1NC2NO2NC
ABW310-jABW301-jABW311-jABW320-jABW302-j
AOW310-jAOW301-jAOW311-jAOW320-jAOW302-j
Ø40mmMushroomHead
1NO1NC1NO-1NC2NO2NC
ABW410-jABW401-jABW411-jABW420-jABW402-j
AOW410-jAOW401-jAOW411-jAOW420-jAOW402-j
Ø40mmMushroomHeadwithFullShroud
1NO1NC1NO-1NC2NO2NC
ABGW410-jABGW401-jABGW411-jABGW420-jABGW402-j
AOGW410-jAOGW401-jAOGW411-jAOGW420-jAOGW402-j
SquareFlush
1NO1NC1NO-1NC2NO2NC
ABQW110-jABQW101-jABQW111-jABQW120-jABQW102-j
AOQW110-jAOQW101-jAOQW111-jAOQW120-jAOQW102-j
SquareExtended
1NO1NC1NO-1NC2NO2NC
ABQW210-jABQW201-jABQW211-jABQW220-jABQW202-j
AOQW210-jAOQW201-jAOQW211-jAOQW220-jAOQW202-j
KeylockPushOn/Off
1NO1NC1NO-1NC2NO2NC
AKW210AKW201AKW211AKW220AKW202
–
1. Inplaceofj,specifytheButtonColorCodefromtable.2. Forsub-assembledpartnumbers,seenextpage.3. Foraccessories,seepage643.4. Fordimensions,seepage645.5. Keyedswitchesaresuppliedwithtwokeys.Allunitsarekeyedalike.
j Button Color CodesColor Code
Black B
Green G
Red R
Blue S
Yellow Y
White W
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
615800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Non-Illuminated Pushbuttons (Sub-Assembled)
Contact Blocks + Operator + Button = Complete Part
Operators
StylePart Number
Momentary Maintained
RoundFlush/Extended
ABW-100 AOW-100
RoundwithFullShroud/Recessed
ABFW-200 AOFW-200
Ø40mm,Ø29mmMushroomHead
ABW-300 AOW-300
Ø40mmMushroomHeadwithFullShroud
ABGW-400 AOGW-400
SquareFlush/Extended
ABQW-100 AOQW-100
KeylockPushOn/Off
— AKW-200
ButtonsStyle Part Number
RoundFlush
ABW1B-j
RoundExtended
ABW2B-j
Ø29mmMushroom
ABW3B-j
Ø40mmMushroom
ABW4B-j
SquareFlush
ABQW1B-j
SquareExtended
ABQW2B-j
Inplaceofjspecifythebuttoncolorcodefromtable
Contact Blocks
StylePart Number
1NO 1NC
StandardEx-posedScrew HW-C10
HW-C10R(earlymake)
HW-C01
HW-C01R(latebreak)
Fingersafe(IP20),CEmarked HW-F10
HW-F10R(earlymake)
HW-F01
HW-F01R(latebreak)
DummyBlock
TW-DB
1. Dummyblocks(nocontacts)areusedwithanoddnumberofcontactblocks.
2. Useofearlyandlatebreakcontactscreatesamakebeforebreakfunction
j Button Color CodesColor Code
Black B
Green G
Red R
Blue S
Yellow Y
White W
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
616 www.IDEC.com
Stop Switches (Assembled)
Assembled Stop Switches
A V (L) W 4 (B) (99) 11 (D) (N) – R – (24V)
Function
V: Pushlock Turn Reset Y: Push-Pull X: Pushlock Key Reset
Illumination
Blank: None L: Illuminated
Series Designation
W: TW Series
Button/Lens Size
3: 29mm Mushroom 4: 40mm Mushroom
Lens Type (illuminated units only)
Blank: Standard (ribbed) B: Engravable (smooth with insert)
Illuminated Circuit (illuminated unit only)
99: Full Voltage (lamp determines voltage) 126: 120V AC Step Down Transformer 246: 240V AC Step Down Transformer 486: 480V AC Step Down Transformer
Lamp Voltage (full voltage illuminated units only)
6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120V AC (LED only) 240V: 240V AC (LED only)
Button/Lens Color
A: Amber R: Red W: White G: Green S: Blue Y: Yellow B: Black
Contact Terminal Style
Blank: Standard N: Fingersafe (IP20)
Lamp Type (illuminated units only)
Blank: Incandescent D: LED
Contact Arrangement
10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO/1NC 22: 2NO/2NC
To be used for interpreting part numbers only, not for part number development.
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
617800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Stop Switches (Assembled), continued
Non-Illuminated Stop SwitchesStyle Contacts Part Number
Ø 40mm Pushlock Turn Reset*
1NO1NC1NO-1NC2NO2NC
AVW410-R*AVW401-R*AVW411-R*AVW420-R*AVW402-R*
Ø 29mm Pushlock Turn Reset*
1NO1NC1NO-1NC2NO2NC
AVW310-R*AVW301-R*AVW311-R*AVW320-R*AVW302-R*
Ø 40mm Push-Pull
1NO1NC1NO-1NC2NO2NC
AYW410-jAYW401-jAYW411-jAYW420-jAYW402-j
Ø 40mm Pushlock Key Reset *
1NO1NC1NO-1NC2NO2NC
AXW410- R*AXW401- R*AXW411- R*AXW420- R*AXW402- R*
1. *Available in Red only.2. In place of j, specify the Button Color Code from table.3. For sub-assembled part numbers, see next page.4. For accessories, see page 643.5. For dimensions, see page 645.
Illuminated Stop SwitchesStyle Type Contacts Part Number
Ø 40mm Pushlock Turn Reset Type
Transformer1NO-1NC2NO2NC
AVLW4 m 11n-R*AVLW4 m 20n-R*AVLW4 m 02n-R*
Full Voltage1NO-1NC2NO2NC
AVLW49911n-R*-l AVLW49920n-R*-l AVLW49902n-R*-l
Ø 29mm Pushlock Turn Reset
Transformer1NO-1NC2NO2NC
AVLW3m11n-R*AVLW3m20n-R*AVLW3m02n-R*
Full Voltage1NO-1NC2NO2NC
AVLW39911n-R*-lAVLW39920n-R*-lAVLW39902n-R*-l
Ø 40mm Push-Pull
Transformer1NO-1NC2NO2NC
AYLW4 m 11n-kAYLW4 m 20n-kAYLW4 m 02n-k
Full Voltage1NO-1NC2NO2NC
AYLW49911n-k-lAYLW49920n-k-lAYLW49902n-k-l
1. *Available in red only.2. In place of k, specify the Lens Color Code (see table above).3. In place of l, specify the Full Voltage Code (lamp voltage) (see table above). 4. In place of m, specify the Transformer Voltage Code (see table above).5. In place of n, specify the Lamp Type Code from table above.6. For sub-assembly part numbers, see next page.7. For accessories, see page 643.8. For dimensions, see page 645.
j Button Color CodesColor Code
Black B
Green G
Red R
Blue S
White W
Yellow Y
k LED/Lens Color CodesColor Code
Amber A
Green G
Red R
Blue S
White W
l Full Voltage CodesVoltage Code
6V AC/DC 6V
12V AC/DC 12V
24V AC/DC 24V
120V AC 120V (LED only)
240V AC 240V (LED only) m Transformer Voltage Codes
Voltage Code
120VAC240VAC480VAC
126246486
Transformers step down to 6V.
n Lamp Type CodesLamp Code
Incandescent Blank
LED D
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
618 www.IDEC.com
Stop Switches (Sub-Assembled)
Transformer/ Adaptor* + Contacts + Lamp Holder + Operator + Lamp + Button or Lens = Complete Part
*Not applicable for full voltage units
Operators
StylePart Number
Non-Illuminated Illuminated
Ø 29/Ø 40mm Push-lock Turn Reset
AVW-300 AVLW3-0600
Ø 40mm Push-Pull
AYW-400 AYLW4-0600
Ø 40mm Pushlock Key Reset
AXW-300 —
ButtonsStyle Part Number
Ø 40mm Pushlock Turn Reset
AVW4B-R*
Ø 29mm Pushlock Turn Reset
AVW3B-R*
Ø 40mm Push-Pull
AYW4B-j
Ø 40mm Pushlock Key Reset
AXW4B-R*
1. *Available in Red only2. In place of j, specify the button color code from table.
Contact BlocksStyle Voltage Part Number
LED
6V AC/DC LSTD-6k
12V AC/DC LSTD-1k
24V AC/DC LSTD-2k
120V AC LSTD-H2k
240V AC LSTD-M4k
Incandescent 6V AC/DC IS-6
12V AC/DC IS-12
24V AC/DC IS-24
1. In place of k, specify the LED color code.2. The LED contains a current-limiting resistor and a
protection diode.
j Button Color CodesColor Code
Black B
Green G
Red R
Blue S
White W
Yellow Y
k LED/Lens Color CodesColor Code
Amber A
Green G
Red R
Blue S
White W
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
619800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Illuminated Stop Switches (Sub-Assembled) continued
Lenses
StylePart Number
Standard Engravable
Ø 29mm Head Pushlock Turn Reset
AVLW3LU-R* AVLW3BLU-R*
Ø 40mm Head Pushlock Turn Reset
AVLW4LU-R* AVLW4BLU-R*
Ø 40mm Head Push Pull
AYLW4LU-k AYLW4BLU-k
1. In place of k, specify the lens color code from table on previous page. 2. *Available only in red3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engrav-
able insert.
Lamp Circuit ComponentsStyle Application Part Number
Short Lamp Holder
Used with a Half-size Transformer and one contact block
TW-LH1
Long Lamp Holder
Used with Full-size Transformer and two contact blocksUsed with Half-size Transformer and three contact blocksUsed with Full Voltage Adaptor and two contact blocks
TW-LH2
Lead Holder
Used with TW-LH2 holder when using four contact blocks
HW-LH3
Transformers/Full Voltage ModulesStyle Description Part Number
Full Size Transformer
Standard
120V AC TW-T126B
240V AC TW-T246B
480V AC TW-T486B
Fingersafe
120V AC TW-F126B
240V AC TW-F246B
480V AC TW-F486B
Half Size Transformer120V AC TW-T126SB
240V AC TW-T246SB
Full voltage model (use with even number of contacts) Standard TW-DA1B
Fingersafe TW-DA1FB
Full voltage model (use with odd number of contacts) Standard HW-DA1B
Fingersafe HW-DA1FB
All Transformers step down to 6V (use 6V lamp).
Contact Blocks
StylePart Number
1NO 1NC
Standard Exposed ScrewHW-C10
HW-C10R(early make)
HW-C01
HW-C01R(late break)
Fingersafe (IP20), CE markedHW-F10
HW-F10R(early make)
HW-F01
HW-F01R(late break)
Dummy Block
TW-DB
1. Dummy blocks (no contacts) are used with an odd number of contact blocks.2. Use of early and late break contacts creates a make before break function
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
620 www.IDEC.com
Pilot Lights (Assembled)
Assembled Pilot Lights
A P (Q) W 1 (B) (99) (D) – R – (24V)
Function
P:PilotLight
Bezel Shape
Blank:Octagonal(roundlenses)Q:Square
Series Designation
W:TWSeries
Lens Shape
1:Flat2:Dome
Lens Type
Blank:Standard(ribbed)B:Engravable(smoothwithinsertincluded)
Illumination Circuit
99: FullVoltage(lampdeterminesvoltage) 126: 120VACStepDownTransformer 246: 240VACStepDownTransformer 486: 480VACStepDownTransformer
Lamp Voltage (FullVoltageUnitsOnly)
6V: 6VAC/DC 12V: 12VAC/DC 24V: 24VAC/DC120V: 120VAC(LEDonly)240V: 240VAC(LEDonly)
Lens Color Code
A: Amber G: GreenR: Red S: BlueW:WhiteY: Yellow
Lamp Type
Blank:IncandescentD:LED
1. Useonlywheninterpretingpartnumbers.Donotusefordevelopingpartnumbers.2. Alltransformersstepdownto6V.
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
621800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Pilot Lights (Assembled) continued
Assembled Pilot LightsStyle Type Voltage Part Number
RoundFlat
Transformer120VAC240VAC480VAC
APW1126m-kAPW1246m-kAPW1486m-k
FullVoltage — APW199m-k-l
Dome
Transformer120VAC240VAC480VAC
APW2126m-kAPW2246m-kAPW2486m-k
FullVoltage — APW299m-k-l
SquareFlat
Transformer120VAC240VAC480VAC
APQW1B126m-kAPQW1B246m-kAPQW1B486m-k
FullVoltage — APQW1B99m-k-l
1. Inplaceofk,specifytheLensColorCodefromtablebelow.2. Inplaceofl,specifytheFullVoltageCodefromtablebelow.3.Inplaceofm,specifytheLampTypeCodefromtablebelow.4. Foraccessories,seepage643.5. Fordimensions,seepage645.6. Forsub-assemblypartnumbers,seenextpage.7.YellowpilotlightcomeswithwhiteLED.
k Lens Color CodesColor Code
Amber A
Green G
Red R
Blue S
White W
Yellow Y
l Full Voltage CodesVoltage Code
6VAC/DC 6V
12VAC/DC 12V
24VAC/DC 24V
120VAC 120V(LEDonly)
240VAC 240V(LEDonly) m Lamp Type Codes
Lamp Code
Incandescent Blank
LED D
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
622 www.IDEC.com
Pilot Lights (Sub-Assembled)
Transformer + Operator + Lamp + Lens = Complete Part
*Transformernotrequiredforfullvoltageunits.
OperatorsStyle Part Number
RoundDome/Flat
APW-199
Square
UPQW-199
Sameoperatorisusedforfullvoltageasfortransformercompletedunits.
Lenses
StylePart Number
Standard Engravable
Dome
APW2LU-k —
RoundFlat
APW1LU-k APW1BLU-k
SquareFlat
— APQW1BLU-k
1. Inplaceofk,specifytheLensColorCodefromtable.2. Standardlenseshavearibbedlenstoenhancelight
dispersion.Markinglensesaresmoothandincludeanengravableinsert.
LampsStyle Voltage Part Number
LED
6VAC/DC LSTD-6k
12VAC/DC LSTD-1k
24VAC/DC LSTD-2k
120VAC LSTD-H2k
240VAC LSTD-M4k
Incandescent 6VAC/DC IS-6
12VAC/DC IS-12
24VAC/DC IS-24
1. Inplaceofk,specifytheLEDcolorcode.2. TheLEDcontainsacurrent-limitingresistoranda
protectiondiode.3.YellowLEDnotavailable.UsewhiteLED.
TransformersStyle Description Part Number
Standard
120VAC TW-T126B
240VAC TW-T246B
480VAC TW-T486B
Fingersafe
120VAC TW-F126B
240VAC TW-F246B
480VAC TW-F486B
AllTransformersstepdownto6V(use6Vlamp).
k LED/Lens Color CodesColor Code
Amber A
Green G
Red R
Blue S
White W
Yellow Y
Ifclearlensisdesired,usewhitemarkinglensandremoveengravinginsert
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
623800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Illuminated Pushbuttons (Assembled)
Assembled Illuminated Pushbuttons
A L (F) W 2 (B) 99 11 (D) (N) – R – (24V)
Function
L:MomentaryActionOL:MaintainedAction
Bezel Shape
Blank:Octagonal(roundlenses)F:FullShroud(roundlenses)Q:Square
Series Designation
W:TWseries
Lens Shape/Size
2:StandardExtended(roundorsquare)3:29mmMushroom4:40mmMushroom
Lens Type
Blank:Standard(ribbed)B:Engravable(smoothwithinsert)
Illumination Circuit
99: FullVoltage(lampdeterminesvoltage)126: 120VACStepDownTransformer246: 240VACStepDownTransformer486: 480VACStepDownTransformer
Lamp Voltage (FullVoltageUnitsOnly)
6V: 6VAC/DC 12V: 12VAC/DC 24V: 24VAC/DC120V: 120VAC(LEDonly)240V: 240VAC(LEDonly)
Lens Code
A: Amber G: Green R: RedS: BlueW:WhiteY: Yellow
Contact Terminal Style
Blank:StandardN: Fingersafe
Lamp Type
Blank: IncandescentLampD: LEDLamp
Contact Arrangement
10:1NO 01:1NC20:2NO 02:2NC11:1NO-1NC 22:2NO-2NC
1. Useonlywheninterpretingpartnumbers.Donotusefordevelopingpartnumbers.2. Transformersstepdownto6V.
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
624 www.IDEC.com
Illuminated Pushbuttons (Assembled)
Illuminated Pushbuttons
Style ContactsPart Number
Momentary Maintained
ExtendedLens Transformer1NO-1NC
2NO2NC
ALW2m11n-kALW2m20n-kALW2m02n-k
AOLW2m11n-kAOLW2m20n-kAOLW2m02n-k
FullVoltage1NO-1NC
2NO2NC
ALW29911n-k-lALW29920n-k-lALW29902n-k-l
AOLW29911n-k-lAOLW29920n-k-lAOLW29902n-k-l
ExtendedLenswithFullShroud Transformer1NO-1NC
2NO2NC
ALFW2m11n-kALFW2m20n-kALFW2m02n-k
AOLFW2m11n-kAOLFW2m20n-kAOLFW2m02n-k
FullVoltage1NO-1NC
2NO2NC
ALFW29911n-k-lALFW29920n-k-lALFW29902n-k-l
AOLFW29911n-k-lAOLFW29920n-k-lAOLFW29902n-k-l
ø29mmMushroomLens Transformer1NO-1NC
2NO2NC
ALW3m11n-kALW3m20n-kALW3m02n-k
AOLW3m11n-kAOLW3m20n-kAOLW3m02n-k
FullVoltage1NO-1NC
2NO2NC
ALW39911n-k-lALW39920n-k-lALW39902n-k-l
AOLW39911n-k-lAOLW39920n-k-lAOLW39902n-k-l
ø40mmMushroomLensTransformer
1NO-1NC2NO2NC
ALW4m11n-kALW4m20n-kALW4m02n-k
AOLW4m11n-kAOLW4m20n-kAOLW4m02n-k
FullVoltage1NO-1NC
2NO2NC
ALW49911n-k-lALW49920n-k-lALW49902n-k-l
AOLW49911n-k-lAOLW49920n-k-lAOLW49902n-k-l
SquareExtended Transformer1NO-1NC
2NO2NC
ALQW2Bm11n-kALQW2Bm20n-kALQW2Bm02n-k
AOLQW2Bm11n-kAOLQW2Bm20n-kAOLQW2Bm02n-k
FullVoltage1NO-1NC
2NO2NC
ALQW2B9911n-k-lALQW2B9920n-k-lALQW2B9902n-k-l
AOLQW2B9911n-k-lAOLQW2B9920n-k-lAOLQW2B9902n-k-l
1. Inplaceofk,specifytheLensColorCode(seetable).Mushroomlensesnotavailableinyellow.2. Inplaceofl,specifytheFullVoltageCode(lampvoltage)(seetable).3. Inplaceofm,specifytheTransformerVoltageCode(seetable).4.Inplaceofn,specifytheLampTypeCodefromtable.5. Forsub-assemblypartnumbers,seenextpage.6. Foraccessories,seepage643.7. Fordimensions,seepage645.8. Lightisindependentofswitchposition.9.YellowpushbuttoncomeswithwhiteLED.
k LED/Lens Color CodesColor Code
Amber A
Green G
Red R
Blue S
White W
Yellow Y
1. Mushroomlensesnotavailableinyellow.
2.YellowpushbuttoncomeswithwhiteLED.
l Full Voltage CodesVoltage Code
6VAC/DC 6V
12VAC/DC 12V
24VAC/DC 24V
120VAC 120V(LEDonly)
240VAC 240V(LEDonly) m Transformer Voltage Codes
Voltage Code
120VAC 126
240VAC 246
480VAC 486
Transformersstepdownto6V(use6Vlamp).
n Lamp Type CodesLamp Code
Incandescent Blank
LED D
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
625800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Illuminated Pushbuttons (Sub-Assembled)
Transformer/ Adaptor* + Contacts + Lamp Holder + Operator + Lamp + Lens = Complete Part
*Notapplicableforfullvoltageunits
Operators
StylePart Number
Momentary Maintained
Extended ALW-0600 AOLW-0600
ExtendedwithFullShroud ALFW-0600 AOLFW-0600
ø29mm/ø40mmMushroom ALW3-0600 AOLW3-0600
Square/Extended ALQW-2B0600 AOLQW-2B0600
Lenses
StylePart Number
Standard Engravable
RoundExtended ALW2LU-k ALW2BLU-k
ø29mmMushroomHead* ALW3LU-k ALW3BLU-k
ø40mmMushroomHead* ALW4LU-k ALW4BLU-k
SquareExtended — ALQW2BLU-k
1. Inplaceofk,specifythelenscolorcodefromtableonthebottomright.2. *Mushroomlensnotavailableinyellow.3. Standardlenseshaveribbedpattern,Engravablelensesaresmoothandincludean
engravableinsert.
LampsStyle Voltage Part Number
LED
6VAC/DC LSTD-6k
12VAC/DC LSTD-1k
24VAC/DC LSTD-2k
120VAC LSTD-H2k
240VAC LSTD-M4k
Incandescent 6VAC/DC IS-6
12VAC/DC IS-12
24VAC/DC IS-24
1. Inplaceofk,specifytheLEDcolorcode.2. TheLEDcontainsacurrent-limitingresistoranda
protectiondiode.
Lamp Circuit ComponentsStyle Application Part Number
ShortLampHolder
Used withaHalf-sizeTransformerandonecontactblock
TW-LH1
LongLampHolder
Used withFull-sizeTransformerandtwocontactblocksUsed with Half-sizeTransformerandthreecontactblocksUsed with FullVoltageAdaptorandtwocontactblocks
TW-LH2
LeadHolder
Used withTW-LH2holderwhenusingfourcontactblocks
HW-LH3
k LED/Lens Color CodesColor Code Color Code
Amber A Blue S
Green G White W
Red R Yellow Y
YellowLEDnotavailable.UsewhiteLED.
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
626 www.IDEC.com
Illuminated Pushbuttons (Sub-Assembled) continued
Contact Blocks
StylePart Number
1NO 1NC
StandardExposedScrewHW-C10
HW-C10R(earlymake)
HW-C01
HW-C01R(latebreak)
Fingersafe(IP20),CEmarkedHW-F10
HW-F10R(earlymake)
HW-F01
HW-F01R(latebreak)
DummyBlock
TW-DB
1. Dummyblocks(nocontacts)areusedwithanoddnumberofcontactblocks.2. Useofearlyandlatebreakcontactscreatesamakebeforebreakfunction
Transformers/Full Voltage ModulesStyle Description Part Number
FullSizeTransformer
Standard
120VAC TW-T126B
240VAC TW-T246B
480VAC TW-T486B
Fingersafe
120VAC TW-F126B
240VAC TW-F246B
480VAC TW-F486B
HalfSizeTransformer
120VAC TW-T126SB
240VAC TW-T246SB
Fullvoltagemodel(usewithevennumberofcontacts) Standard TW-DA1B
Fingersafe TW-DA1FB
Fullvoltagemodel(usewithoddnumberofcontacts) Standard HW-DA1B
Fingersafe HW-DA1FB
AllTransformersstepdownto6V(use6Vlamp).
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
627800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Non-Illuminated Selector Switches (Assembled)
Assembled Selector Switches
A S W 3 (1) (L) 20 (N) – 304
Function
S: SelectorSwitch
Series Designation
W:TWSeries
Number of Positions
2: 2-Position3: 3-Position4:4-Position5:5-Position
Spring Return Action
Blank:Maintained1: SpringreturnfromRight(2or3position)2: SpringreturnfromLeft(2or3position)3: 2-WayspringreturnfromLeftandRight(3positiononly)
Circuit Number
(Standardcircuitsshownonfollowingpagesand635.)
Contacts Terminal Style
Blank:standardN:Fingersafe(IP20)
Contact Arrangement Code
10:1NO 01:1NC20:2NO 02:2NC40:4NO 04:4NC11:1NO-1NC22:2NO-2NC
Operator Style Code
Blank: KnobOperatorL: LeverOperatorK: KeyOperator
1. Useonlywheninterpretingpartnumbers.Donotusefordevelopingpartnumbers.2. Customcontactconfigurationsavailable.3. Customkeyremovablecodesavailable.4. Portionsofpartnumberinside()areoptional.
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
628 www.IDEC.com
Non-Illuminated Selector Switches (Assembled) continued
2-Position Selector SwitchesStyle Part Number
Cont
act
Mou
ntin
g
Operator Position Maintained Spring Return
from RightSpring Return
from Left
L R L R L R L R
1NO 12
OO
XO
KnobLeverKey
ASW210ASW2L10ASW2K10
ASW2110ASW21L10ASW21K10
ASW2210ASW22L10ASW22K10
1NC 12
XO
OO
KnobLeverKey
ASW201-116ASW2L01-116ASW2K01-116
ASW2101-116ASW21L01-116ASW21K01-116
ASW2201-116ASW22L01-116ASW22K01-116
1NO1NC
12
XO
OX
KnobLeverKey
ASW211ASW2L11ASW2K11
ASW2111ASW21L11ASW21K11
ASW2211ASW22L11ASW22K11
2NO 12
OO
XX
KnobLeverKey
ASW220ASW2L20ASW2K20
ASW2120ASW21L20ASW21K20
ASW2220ASW22L20ASW22K20
2NC 12
XX
OO
KnobLeverKey
ASW202-104ASW2L02-104ASW2K02-104
ASW2102-104ASW21L02-104ASW21K02-104
ASW2202-104ASW22L02-104ASW22K02-104
2NO2NC
1234
OXOX
XOXO
KnobLeverKey
ASW222ASW2L22ASW2K22
ASW2122ASW21L22ASW21K22
ASW2222ASW22L22ASW22K22
2NO2NC
1234
OOXX
XXOO
KnobLeverKey
ASW222-111ASW2L22-111ASW2K22-111
ASW2122-111ASW21L22-111ASW21K22-111
ASW2222-111ASW22L22-111ASW22K22-111
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
629800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Non-Illuminated Selector Switches (Assembled) continued
3-Position Selector SwitchesStyle Part Number
Cont
act
Mou
ntin
g Operator Position Maintained Spring Return from Right Spring Return from Left Spring Return Two-Way
L C RL
CR L
CR L
CR L
CR
2NO 12
XO
OO
OX
KnobLeverKey
ASW320ASW3L20ASW3K20
ASW3120ASW31L20ASW31K20
ASW3220ASW32L20ASW32K20
ASW3320ASW33L20ASW33K20
2NC 12
OX
XX
XO
KnobLeverKey
ASW302ASW3L02ASW3K02
ASW3102ASW31L02ASW31K02
ASW3202ASW32L02ASW32K02
ASW3302ASW33L02ASW33K02
2NO2NC
1234
XOOX
OOXX
OXXO
KnobLeverKey
ASW322ASW3L22ASW3K22
ASW3122ASW31L22ASW31K22
ASW3222ASW32L22ASW32K22
ASW3322ASW33L22ASW33K22
2NO2NC
1234
XXOO
OXXO
XOOX
KnobLeverKey
ASW322-309ASW3L22-309ASW3K22-309
ASW3122-309ASW31L22-309ASW31K22-309
ASW3222-309ASW32L22-309ASW32K22-309
ASW3322-309ASW33L22-309ASW33K22-309
2NO2NC
1234
OOOO
XOXO
OXOX
KnobLeverKey
ASW322-310ASW3L22-310ASW3K22-310
ASW3122-310ASW31L22-310ASW31K22-310
ASW3222-310ASW32L22-310ASW32K22-310
ASW3322-310ASW33L22-310ASW33K22-310
4NO
1234
XOXO
OOOO
OXOX
KnobLeverKey
ASW340ASW3L40ASW3K40
ASW3140ASW31L40ASW31K40
ASW3240ASW32L40ASW32K40
ASW3340ASW33L40ASW33K40
4NC
1234
OXOX
XXXX
XOXO
KnobLeverKey
ASW304ASW3L04ASW3K04
ASW3104ASW31L04ASW31K04
ASW3204ASW32L04ASW32K04
ASW3304ASW33L04ASW33K04
1. Thetruthtableindicatestheoperatingpositionofcontactblockwhentheoperatorisswitchedtothatposition. X=On(closedcontacts)
O=Off(opencontacts)X X=OverlappingContacts:Remainon(closedcontacts)whenswitchismovedbetweenthesetwopositions.
2. Allknobandleverselectorswitchescomeinblack.Othercolorsareavailablebyorderingtheknoborleverseparately.3. Everykeyselectorswitchusesanidenticalkey.Thekeyisremovableinanymaintainedposition.4. Customcontactconfigurationsareavailable,seepage635.
4-Position Selector SwitchStyle Maintained
Cont
act
Mou
ntin
g Operator Position Part Number
1 2 3 4 12
3
4
2NO2NC
1234
XOOO
OXOO
OOXO
OOOX
KnobLever
ASW422-411ASW4L22-411
5-Position Selector SwitchStyle Maintained
Cont
act
Mou
ntin
g Operator Position Part Number
1 2 3 4 51
2 3 45
2NO2NC
1234
XOOO
OXOO
OOOO
OOXO
OOOX
KnobLever
ASW522-501ASW5L22-501
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
630 www.IDEC.com
Non-Illuminated Selector Switches (Sub-Assembled)
Contact Blocks + Operator + Knob or Lever* + Color Insert* = Complete Part†
1. *Notneededwithkeytypeswitches.2. †Knobtypeshown.
OperatorsStyle Positions Description Part Number
Knob/Lever
2
Maintained ASW200
Springreturnfromright ASW2100
Springreturnfromleft ASW2200
3
Maintained,Cam1Maintained,Cam2Maintained,Cam3
ASW300-1ASW300-2ASW300-3
Springreturnfromright,Cam1Springreturnfromright,Cam2
ASW3100-1ASW3100-2
Springreturnfromleft,Cam1Springreturnfromleft,Cam2
ASW3200-1ASW3200-2
Springreturnfromleft/right,Cam1Springreturnfromleft/right,Cam2
ASW3300-1ASW3300-2
4 Maintained,StandardCamMaintained,Cam1
ASW400ASW400-1
5 Maintained,StandardcamMaintained,Cam1
ASW500ASW500-1
Key2
Maintained ASW2K00
Springreturnfromright ASW21K00
Springreturnfromleft ASW22K00
3
Maintained,Cam1Maintained,Cam2Maintained,Cam3
ASW3K00-1ASW3K00-2ASW3K00-3
Springreturnfromright,Cam1Springreturnfromright,Cam2
ASW31K00-1ASW31K00-2
Springreturnfromleft,Cam1Springreturnfromleft,Cam2
ASW32K00-1ASW32K00-2
Springreturnfromleft/right,Cam1Springreturnfromleft/right,Cam2
ASW33K00-1ASW33K00-2
1. Twokeysaresuppliedwitheverykeyswitch,allarekeyedalike,andremovablefromanymaintainedposition.2. Lockingringsareincludedwithalloperators.Orderknobs,levers,andcolorinsertsseparately.3. Differentcamsproducedifferentcontactactions.Fordetails,seepage635.4. Keyswitchoperatorsuppliedwithblacksleeve.
Handles and InsertsStyle Part Number
Knob ASWHHY-j
Lever ASWHHL-j
ColorInsert TW-HC1-j
Contact Blocks
StylePart Number
1NO 1NC
StandardExposedScrew HW-C10
HW-C10R(earlymake)
HW-C01
HW-C01R(latebreak)
Fingersafe(IP20),CEmarked HW-F10
HW-F10R(earlymake)
HW-F01
HW-F01R(latebreak)
DummyBlock
TW-DB
1. Pushrodcolorcode:Green=NOcontactblockRed=NCcontactblock.
2. Dummyblocks(nocontacts)areusedwithanoddnumberofcontactblocks.
j Handle/Insert Color CodesColor Code
Black* B
Blue S
Green G
Red R
Yellow Y
White† W
*Colorinsertsnotavailableinblack.†Knobandlevernotavailableinwhite.
Replacement PartsKey Switch Black Sleeve AKW2B-B
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
631800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Illuminated Selector Switches (Assembled)
Assembled Illuminated Selector Switches
A SL W 2 (2) 99 11 (D) (N) – (103) – R – (24V)
Function
SL:IlluminatedSelectorSwitch
Series Designation
W:TWseries
Number of Positions
2:2-Position3:3-Position
Spring Return Action
Blank:Maintained1:SpringreturnfromRight2:SpringreturnfromLeft3:Two-WayspringreturnfromLeftandRight
Illumination Circuit
99: FullVoltage(lampdeterminesvoltage)126: 120VACStepDownTransformer246: 240VACStepDownTransformer486: 480VACStepDownTransformer
Lamp Voltage (FullVoltageUnitsOnly)
6V: 6VAC/DC 12V: 12VAC/DC 24V: 24VAC/DC120V: 120VAC(LEDonly)240V: 240VAC(LEDonly)
Lens Color Code
A: Amber G: Green R: RedS: BlueW:WhiteY: Yellow
Contact Circuit Number
Standardcircuitsarelistedonthefollowingpagesand635.
Contact Terminal Style
Blank:StandardN: Fingersafe
Lamp Type
Blank:IncandescentLampD:LEDLamp
Contact Arrangement
10:1NO 01:1NC20:2NO 02:2NC40:4NO 04:4NC11:1NO-1NC 22:2NO-2NC
1. Useonlywheninterpretingpartnumbers.Donotusefordevelopingpartnumbers.2. Alltransformersstepdownto6V(use6Vlamp).
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
632 www.IDEC.com
Illuminated Selector Switches(Assembled) continued
Illuminated 2-Position Selector SwitchesStyle Part Number
Cont
act
Mou
ntin
g OperatorPosition Lamp
Circuit Type
Maintained Spring Return from Right Spring Return from Left
L R L R L RL R
1NO1NC
12
OX
XO
TransformerFullVoltage
ASLW2j11m-kASLW29911m-k-l
ASLW21j11m-kASLW219911m-k-l
ASLW22j11m-kASLW229911m-k-l
2NO 12
OO
XX
TransformerFullVoltage
ASLW2j20m-kASLW29920m-k-l
ASLW21j20m-kASLW219920m-k-l
ASLW22j20m-kASLW229920m-k-l
2NC 12
XX
OO
TransformerFullVoltage
ASLW2j02m-104-kASLW29902m-104-k-l
ASLW21j02m-104-kASLW219902m-104-k-l
ASLW22j02m-104-kASLW229902m-104-k-l
2NO2NC
1234
OXOX
XOXO
TransformerFullVoltage
ASLW2j22m-kASLW29922m-k-l
ASLW21j22m-kASLW219922m-k-l
ASLW22j22m-kASLW229922m-k-l
Illuminated 3-Position Selector Switches, Maintained and Spring Return from RightStyle Part Number
Cont
act
Mou
ntin
g Operator PositionLamp
Circuit Type
Maintained Spring Return From Right Spring Return from Left Spring Return Two-Way
L C RL
CR L
CR L
CR L
CR
2NO 12
XO
OO
OX
TransformerFullVoltage
ASLW3j20m-kASLW39920m-k-l
ASLW31j20m-kASLW319920m-k-l
ASLW32j20m-kASLW329920m-k-l
ASLW33j20m-kASLW339920m-k-l
2NC 12
OX
XX
XO
TransformerFullVoltage
ASLW3j02m-kASLW39902m-k-l
ASLW31j02m-kASLW319902m-k-l
ASLW32j02m-kASLW329902m-k-l
ASLW33j02m-kASLW339902m-k-l
2NO2NC
1234
XOOX
OOXX
OXXO
TransformerFullVoltage
ASLW3j22m-kASLW39922m-k-l
ASLW31j22m-kASLW319922m-k-l
ASLW32j22m-kASLW329922m-k-l
ASLW33j22m-kASLW339922m-k-l
2NO2NC
1234
XXOO
OXXO
XOOX
TransformerFullVoltage
ASLW3j22m-309-kASLW39922m-309-k-l
ASLW31j22m-309-kASLW319922m-309-k-l
ASLW32j22m-309-kASLW329922m-309-k-l
ASLW33j22m-309-kASLW339922m-309-k-l
2NO2NC
1234
OOOO
XOXO
OXOX
TransformerFullVoltage
ASLW3j22m-310-kASLW39922m-310-k-l
ASLW31j22m-310-kASLW319922m-310-k-l
ASLW32j22m-310-kASLW329922m-310-k-l
ASLW33j22m-310-kASLW339922m-310-k-l
4NO
1234
XOXO
OOOO
OXOX
TransformerFullVoltage
ASLW3j40m-kASLW39940m-k-l
ASLW31j40m-kASLW319940m-k-l
ASLW32j40m-kASLW329940m-k-l
ASLW33j40m-kASLW339940m-k-l
4NC
1234
OXOX
XXXX
XOXO
TransformerFullVoltage
ASLW3j04m-kASLW39904m-k-l
ASLW31j04m-kASLW319904m-k-l
ASLW32j04m-kASLW329904m-k-l
ASLW33j04m-kASLW339904m-k-l
1. Inplaceofj,specifytheTransformerVoltageCode.2. Inplaceofk,specifytheLens/LEDColorCode.3. Inplaceofl,specifytheFullVoltageCode.4. InplaceofmspecifyLampTypeCode5. Forcustomcontactconfigurations,seepage635.6. Lightisindependentofswitchposition.7.YellowselectorswitchcomeswithwhiteLED.
l Full Voltage CodesVoltage Code
6VAC/DC 6V
12VAC/DC 12V
24VAC/DC 24V
120VAC 120V(LEDonly)
240VAC 240V(LEDonly)
m Lamp Type CodesLamp Code
Incandescent Blank
LED D
j Transformer Voltage CodesVoltage Code
120VAC 126
240VAC 246
480VAC 486
Transformersstepdownto6V(use6Vlamp).
k LED/Lens Color Codes
Color Code
Amber A
Green G
Red R
Blue S
White W
Yellow Y
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
633800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Illuminated Selector Switches (Sub-Assembled)
Transformer* + Contact Block + Operator + Lamp/Lead Holder† + Lamp + Lens = Complete Part
*Fullvoltageunitsuseafullvoltageadaptor(TW-DA1B)insteadofatransformer.†Lampholderisnotincludedwithoperators,orderseparately.Leadholderisusedwhenusing3ormorecontactblocks.Orderseparately.
OperatorsStyle Positions Description Part Number
2
Maintained ASLW200
Springreturnfromright ASLW2100
Springreturnfromleft ASLW2200
3
Maintained,cam1Maintained,cam2Maintained,cam3
ASLW300-1
ASLW300-2
ASLW300-3
Springreturnfromright,cam1Springreturnfromright,cam2
ASLW3100-1
ASLW3100-2
Springreturnfromleft,cam1Springreturnfromleft,cam2
ASLW3200-1
ASLW3200-2
Springreturnfromleft/right,cam1Springreturnfromleft/right,cam2
ASLW3300-1
ASLW3300-2
Differentcamsproducedifferentcontactaction.Fordetails,seeContactArrangementsonpage635.
Lenses (Knobs)Style Part Number
Knob ASLWLU-k
Inplaceofk,specifythelenscolorcodefromtable.
LampsStyle Voltage Part Number
LED
6VAC/DC LSTD-6k
12VAC/DC LSTD-1k
24VAC/DC LSTD-2k
120VAC LSTD-H2k
240VAC LSTD-M4k
Incandescent 6VAC/DC IS-6
12VAC/DC IS-12
24VAC/DC IS-24
1. Inplaceofk,specifytheLEDcolorcode.2. TheLEDcontainsacurrent-limitingresistoranda
protectiondiode.
k LED/Lens Color CodesColor Code
Amber A
Green G
Red R
Blue S
White W
Yellow Y
YellowLEDnotavailable.UsewhiteLED
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
634 www.IDEC.com
Illuminated Selector Switches (Sub-Assembled) continued
Contact Blocks
StylePart Number
1NO 1NC
StandardExposedScrewHW-C10
HW-C10R(earlymake)
HW-C01
HW-C01R(latebreak)
Fingersafe(IP20),CEmarkedHW-F10
HW-F10R(earlymake)
HW-F01
HW-F01R(latebreak)
DummyBlock
TW-DB
1. Dummyblocks(nocontacts)areusedwithanoddnumberofcontactblocks.2. Useofearlyandlatebreakcontactscreatesamakebeforebreakfunction
Lamp Circuit Components
Style Application Part Number
ShortLampHolder
Used withaHalf-sizeTransformerandonecontactblock
TW-LH1
LongLampHolder
Used withFull-sizeTransformerandtwocontactblocksUsed with Half-sizeTransformerandthreecontactblocksUsed with FullVoltageAdaptorandtwocontactblocks
TW-LH2
LeadHolder
Used withTW-LH2holderwhenusingfourcontactblocks
HW-LH3
Transformers/Full Voltage ModulesStyle Description Part Number
FullSizeTransformer
Standard
120VAC TW-T126B
240VAC TW-T246B
480VAC TW-T486B
Fingersafe
120VAC TW-F126B
240VAC TW-F246B
480VAC TW-F486B
HalfSizeTransformer
120VAC TW-T126SB
240VAC TW-T246SB
Fullvoltagemodel(usewithevennumberofcontacts) Standard TW-DA1B
Fingersafe TW-DA1FB
Fullvoltagemodel(usewithoddnumberofcontacts) Standard HW-DA1B
Fingersafe HW-DA1FB
AllTransformersstepdownto6V(use6Vlamp).
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
635800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Contact Arrangement Charts
How to Read Contact Arrangement Charts
Todeterminecontactblockmountingposition,firstmakesuretheselectorswitchisorientedasshownontheright
Contact ArrangementTypeandquantityofswitchcontacts
Circuit Number*N/D=Nodesignationrequired
Contact Block Mounting PositionPositionormountingcontactblocksonoperator
Operator PositionTruthtableindicatestheoper-atingpositionofcontactblockwhenoperatorisswitchedtothatposition.
Contact Block Part NumberPartnumbertousewhenorderingsub-assemblycontactblocks,asrequiredforusewithcorrespondingmountingpositionContact Arrangement Chart: 2-Position Selector Switches
Style
Mounting Position
Operator Position Contact Block
Part Number Description
Operator Part Number
Contact Circuit Number
Maintained Spring Ret. from Rt.
Spring Ret. from Lt.
L R L R L R L R
1NO N/D1 O X HW-C10 Knob/Lever
KeyIlluminatedKnob
ASW200ASW2K00ASLW200
ASW2100ASW21K00ASLW2100
ASW2200ASW22K00ASLW22002 O O TW-DB
1NC 1161 X O HW-C01 Knob/Lever
KeyIlluminatedKnob
ASW200ASW2K00ASLW200
ASW2100ASW21K00ASLW2100
ASW2200ASW22K00ASLW22002 O O TW-DB
1NO1NC
N/D1 O X HW-C10 Knob/Lever
KeyIlluminatedKnob
ASW200ASW2K00ASLW200
ASW2100ASW21K00ASLW2100
ASW2200ASW22K00ASLW22002 X O HW-C01
1031 X O HW-C01 Knob/Lever
KeyIlluminatedKnob
ASW200ASW2K00ASLW200
ASW2100ASW21K00ASLW2100
ASW2200ASW22K00ASLW22002 O X HW-C10
1NO-EM1NC-LB
6001 O X HW-C10R Knob/Lever
KeyIlluminatedKnob
ASW200ASW2K00ASLW200
ASW2100ASW21K00ASLW2100
ASW2200ASW22K00ASLW22002 X O HW-C01R
6011 X O HW-C01R Knob/Lever
KeyIlluminatedKnob
ASW200ASW2K00ASLW200
ASW2100ASW21K00ASLW2100
ASW2200ASW22K00ASLW22002 O X HW-C10R
2NO N/D1 O X HW-C10 Knob/Lever
KeyIlluminatedKnob
ASW200ASW2K00ASLW200
ASW2100ASW21K00ASLW2100
ASW2200ASW22K00ASLW22002 O X HW-C10
2NC 1041 X O HW-C01 Knob/Lever
KeyIlluminatedKnob
ASW200ASW2K00ASLW200
ASW2100ASW21K00ASLW2100
ASW2200ASW22K00ASLW22002 X O HW-C01
2NO2NC
N/D
1 O X HW-C10
Knob/LeverKeyIlluminatedKnob
ASW200ASW2K00ASLW200
ASW2100ASW21K00ASLW2100
ASW2200ASW22K00ASLW2200
2 X O HW-C01
3 O X HW-C10
4 X O HW-C01
111
1 O X HW-C10
Knob/LeverKeyIlluminatedKnob
ASW200ASW2K00ASLW200
ASW2100ASW21K00ASLW2100
ASW2200ASW22K00ASLW2200
2 O X HW-C10
3 X O HW-C01
4 X O HW-C01
1. NO-EM,NC-LB=EarlyMake,LateBreak.N/D=Nocircuitnumberdesignationrequiredinassembledselectorswitchpartnumber.
2. X=On(closedcontacts)O=Off(Opencontacts)
2
3
4L
R
1
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
636 www.IDEC.com
Contact Arrangement Chart: 3-Position Selector SwitchesStyle
MountingPosition
Operator PositionContact Block Part Number Description
Operator Part Number
Contact Circuit Number
Maintained Spring Return from Right
Spring Return from Left Two-Way
L C RL
CR L
CR L
CR L
CR
1NO1NC
2021 X 0 0 HW-C10 Knob/Lever
KeyIlluminatedKnob
ASW300-1ASW3K00-1ASLW300-1
ASW3100-1ASW31K00-1ASLW3100-1
ASW3200-1ASW32K00-1ASLW3200-1
ASW3300-1ASW33K00-1ASLW3300-12 X X O HW-C01
2031 0 X X HW-C01 Knob/Lever
KeyIlluminatedKnob
ASW300-1ASW3K00-1ASLW300-1
ASW3100-1ASW31K00-1ASLW3100-1
ASW3200-1ASW32K00-1ASLW3200-1
ASW3300-1ASW33K00-1ASLW3300-12 O 0 X HW-C10
3021 X 0 X HW-C10 Knob/Lever
KeyIlluminatedKnob
ASW300-2ASW3K00-2ASLW300-2
ASW3100-2ASW31K00-2ASLW3100-2
ASW3200-2ASW32K00-2ASLW3200-2
ASW3300-2ASW33K00-2ASLW3300-22 X X O HW-C01
3031 0 X O HW-C01 Knob/Lever
KeyIlluminatedKnob
ASW300-2ASW3K00-2ASLW300-2
ASW3100-2ASW31K00-2ASLW3100-2
ASW3200-2ASW32K00-2ASLW3200-2
ASW3300-2ASW33K00-2ASLW3300-22 O 0 X HW-C10
2NO
N/D1 X 0 0 HW-C10 Knob/Lever
KeyIlluminatedKnob
ASW300-1ASW3K00-1ASLW300-1
ASW3100-1ASW31K00-1ASLW3100-1
ASW3200-1ASW32K00-1ASLW3200-1
ASW3300-1ASW33K00-1ASLW3300-12 O 0 X HW-C10
3011 X 0 X HW-C10 Knob/Lever
KeyIlluminatedKnob
ASW300-2ASW3K00-2ASLW300-2
ASW3100-2ASW31K00-2ASLW3100-2
ASW3200-2ASW32K00-2ASLW3200-2
ASW3300-2ASW33K00-2ASLW3300-22 O 0 X HW-C10
2NC
3041 0 X O HW-C01 Knob/Lever
KeyIlluminatedKnob
ASW300-2ASW3K00-2ASLW300-2
ASW3100-2ASW31K00-2ASLW3100-2
ASW3200-2ASW32K00-2ASLW3200-2
ASW3300-2ASW33K00-2ASLW3300-22 X X O HW-C01
N/D1 0 X X HW-C01 Knob/Lever
KeyIlluminatedKnob
ASW300-1ASW3K00-1ASLW300-1
ASW3100-1ASW31K00-1ASLW3100-1
ASW3200-1ASW32K00-1ASLW3200-1
ASW3300-1ASW33K00-1ASLW3300-12 X X O HW-C01
2NO2NC
N/D
1 X 0 0 HW-C10Knob/LeverKeyIlluminatedKnob
ASW300-1ASW3K00-1ASLW300-1
ASW3100-1ASW31K00-1ASLW3100-1
ASW3200-1ASW32K00-1ASLW3200-1
ASW3300-1ASW33K00-1ASLW3300-1
2 0 0 X HW-C10
3 0 X X HW-C01
4 X X 0 HW-C01
210
1 0 X X HW-C01Knob/LeverKeyIlluminatedKnob
ASW300-1ASW3K00-1ASLW300-1
ASW3100-1ASW31K00-1ASLW3100-1
ASW3200-1ASW32K00-1ASLW3200-1
ASW3300-1ASW33K00-1ASLW3300-1
2 0 0 X HW-C10
3 0 X X HW-C01
4 0 0 X HW-C10
308
1 X 0 X HW-C10Knob/LeverKeyIlluminatedKnob
ASW300-2ASW3K00-2ASLW300-2
ASW3100-2ASW31K00-2ASLW3100-2
ASW3200-2ASW32K00-2ASLW3200-2
ASW3300-2ASW33K00-2ASLW3300-2
2 X X 0 HW-C01
3 X 0 X HW-C10
4 X X O HW-C01
309
1 X 0 X HW-C10Knob/LeverKeyIlluminatedKnob
ASW300-2ASW3K00-2ASLW300-2
ASW3100-2ASW31K00-2ASLW3100-2
ASW3200-2ASW32K00-2ASLW3200-2
ASW3300-2ASW33K00-2ASLW3300-2
2 X X 0 HW-C01
3 0 X O HW-C01
4 O 0 X HW-C10
310
1 0 X O HW-C01Knob/LeverKeyIlluminatedKnob
ASW300-2ASW3K00-2ASLW300-2
ASW3100-2ASW31K00-2ASLW3100-2
ASW3200-2ASW32K00-2ASLW3200-2
ASW3300-2ASW33K00-2ASLW3300-2
2 O 0 X HW-C10
3 0 X O HW-C01
4 0 0 X HW-C10
1. Eachoperatorsub-assemblyisavailableasa“-1”anda“-2”for3-positionselectorswitches.Theinternalcamofa“-1”isdifferentfromthatofa“-2”.Thisresultsindesignatedcombinationsofopenandclosedcontactsinthevariousoperatorpositions.
2. N/D=Nocircuitnumberdesignationrequiredinassembledpartnumber.3. X=On(closedcontacts)O=Off(opencontacts).XXOverlappingcontactsremainon(closed)whenswitchismovedbetweenthesetwopositions.
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
637800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Contact Arrangement Chart: 3-Position Selector SwitchesStyle
MountingPosition
Operator PositionContact Block Part Number Description
Operator Part Number
Contact Circuit Number
Maintained Spring Return from Right
Spring Return from Left Two-Way
L C RL
CR L
CR L
CR L
CR
4NO
N/D
1 X 0 0 HW-C10Knob/LeverKeyIlluminatedKnob
ASW300-1ASW3K00-1ASLW300-1
ASW3100-1ASW31K00-1ASLW3100-1
ASW3200-1ASW32K00-1ASLW3200-1
ASW3300-1ASW33K00-1ASLW3300-1
2 0 0 X HW-C10
3 X 0 0 HW-C10
4 0 0 X HW-C10
305
1 X 0 X HW-C10Knob/LeverKeyIlluminatedKnob
ASW300-2ASW3K00-2ASLW300-2
ASW3100-2ASW31K00-2ASLW3100-2
ASW3200-2ASW32K00-2ASLW3200-2
ASW3300-2ASW33K00-2ASLW3300-2
2 0 0 X HW-C10
3 X 0 X HW-C10
4 0 0 X HW-C10
4NC
N/D
1 0 X X HW-C01Knob/LeverKeyIlluminatedKnob
ASW300-1ASW3K00-1ASLW300-1
ASW3100-1ASW31K00-1ASLW3100-1
ASW3200-1ASW32K00-1ASLW3200-1
ASW3300-1ASW33K00-1ASLW3300-1
2 X X 0 HW-C01
3 0 X X HW-C01
4 X X O HW-C01
314
1 0 X O HW-C01Knob/LeverKeyIlluminatedKnob
ASW300-2ASW3K00-2ASLW300-2
ASW3100-2ASW31K00-2ASLW3100-2
ASW3200-2ASW32K00-2ASLW3200-2
ASW3300-2ASW33K00-2ASLW3300-2
2 X X 0 HW-C01
3 0 X O HW-C01
4 X X 0 HW-C01
1. Eachoperatorsub-assemblyisavailableasa“-1”anda“-2”for3-positionselectorswitches.Theinternalcamofa“-1”isdifferentfromthatofa“-2”.Thisresultsindesignatedcombinationsofopenandclosedcontactsinthevariousoperatorpositions.
2. N/D=Nocircuitnumberdesignationrequiredinassembledpartnumber.3. X=On(closedcontacts)O=Off(opencontacts).XXOverlappingcontactsremainon(closed)whenswitchismovedbetweenthesetwopositions.
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
638 www.IDEC.com
Custom Selector Switch Building Guide
Tobuildacustomselectorswitch,followthesesteps.
Step 1
Howmanypositionsoftheswitchareneeded?
# of positions (2, 3, 4, 5)
Step 2
Howmanycontactsshouldtherebe?
# of isolated contacts (maximum 6)
Step 3
FillintheTruthTable
(X=closed,0=open)
Knob Position
1 2 3 4 5
Cont
acts
1
2
3
4
5
6
Step 4
Ifbuildinga2positionselector,skipthisstep.(2positionselectorshaveonlyonecam)
Ifbuildinga3,4,or5positionselector,determineappropriatecamasfollows:• LookatRow1fromabovetableandlocateanidenticalrowintheoperatortruthtables(Seenextpage).• Repeatforallrows.Theusermustfindoneoperatorthatcontainsallrowsfromabovetable.• Recordtheoperatorcamversion.
Step 5
Buildbyplacingappropriatecontactinappropriatemountingpositionforeachdesiredrowonoperatorcamtruthtable.“L”and“R”refertomountingonleftorrightsideofoperatorasviewedfromthefrontofthepanel.
Step 6
Developanassemblypartnumber(ifnecessary)asfollows:followstandardnumberingnomenclatureforselectorswitches(seepages627or631.Inplaceofthe“CircuitNumber”indicatethecamnumberandcontactarrangementassuchASW322-3-OELCSS,where“3”isthecamnumber,andcontactarrangement“OELCXX”callsoutindividualcontactmountinglocationsinorder(seediagramabove).O=NO,C=NC,E=NO-EM,L=NC-LB,X=nocontact.Partnumbermustdesignateall6pos-siblemountinglocations.
Caution:Beforeputtinganycustomselectorswitchintouse,theusershoulduseanohmmetertotestfordesiredperformance.1. ForOperatorTruthTables,seenextpage.
2
3
4L
R
1
Mounting Positions
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
639800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Operator Truth Tables
Usethefollowingtablestobuildcustomselectorswitches.
2 Position Selector Switches
Contact MountingPosition
Operator Position
Left Right
ASW200ASLW200ASW2K00
HW-C10(NO)
L O X
R O X
HW-C01(NC)
L X O
R X O
HW-C10R(NO-EM)
L O X
R O X
HW-C01R(NC-LB)
L X O
R X O
3 Position Selector Switches
Contact MountingPosition
Operator Position
Left Center Right
ASW300-1ASW3K00-1ASLW300-1
HW-C10(NO)
L X O O
R O O X
HW-C01(NC)
L O X X
R X X O
HW-C10R(NO-EM)
L X O O
R O O X
HW-C01R(NC-LB)
L O X X
R X X O
Contact MountingPosition
Operator Position
Left Center Right
ASW300-2ASW3K00-2ASLW300-2
HW-C10(NO)
L X O X
R O O X
HW-C01(NC)
L O X O
R X X O
HW-C10R(NO-EM)
L X O X
R O O X
HW-C01R(NC-LB)
L O X O
R X X O
Contact MountingPosition
Operator Position
Left Center Right
ASW300-3ASW3K00-3ASLW300-3
HW-C10(NO)
L X O O
R O O X
HW-C01(NC)
L O X O
R O X O
HW-C10R(NO-EM)
L X O X
R X O X
HW-C01R(NC-LB)
L O X X
R X X O
4 Position Selector Switches
Contact MountingPosition
Operator Position
1 2 3 4
ASW400
HW-C10(NO)
L X O O O
R O X O O
HW-C01(NC)
L O X X X
R X O X X
HW-C10R(NO-EM)
L X O O O
R O X O O
HW-C01R(NC-LB)
L O X X X
R X O X X
Contact MountingPosition
Operator Position
1 2 3 4
ASW400-1
HW-C10(NO)
L X O O O
R O O O X
HW-C01(NC)
L O O X O
R O X O O
HW-C10R(NO-EM)
L X X O X
R X O X X
HW-C01R(NC-LB)
L O X X X
R X X X O
5 Position Selector Switches
Contact MountingPosition
Operator Position
1 2 3 4 5
ASW500
HW-C10(NO)
L X O O O O
R O X O O O
HW-C01(NC)
L O O X X X
R O O O X X
HW-C10R(NO-EM)
L X O O O O
R O X O O O
HW-C01R(NC-LB)
L O X X X X
R X O X X X
Contact MountingPosition
Operator Position
1 2 3 4 5
ASW500-1
HW-C10(NO)
L X O O O O
R O O O O X
HW-C01(NC)
L O O O X O
R O X O O O
HW-C10R(NO-EM)
L X X X O X
R X O X X X
HW-C01R(NC-LB)
L O X X X X
R X X X X O
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
640 www.IDEC.com
Nameplates — TW Series
FaceplatesNWAL NWAQL NWAS EMERGENCY STOP
1.13" (29mm)1.
0"
(25.
4mm
)
1.13" (29mm)
0.97
5"(2
5mm
)0.
566"
(14.
5mm
)
1.76" (45mm)
1.76
" (4
5mm
)
ø70m
m
Part Number
Nameplate(blank)
NWAL-OB(black)NWAL-OR(red)
NWAQL-OB(black)NWAQL-OR(red) NWAS-OB NWAR-O
Nameplate(engraved) NWAL-j NWAQL-j NWAS-j NWAR-27†
1. Inplaceofj,inserteithertheStandardLegendCodefromtablebeloworcustomengravingdelimitedby““.2. Standardengravingsareavailableatnocharge.3 NWAR-27comesmarked“EmergencyStop”asshownindrawing.
Standard Legend CodesPushbuttons Pushbuttons/Selector Switches Selector Switches
Legend Code Legend Code Legend Code Legend Code Legend Code
AUTOCLOSEDOWNEMERG.STOPFASTFORWARDHANDHIGHININCHJOGLOWLOWEROFFON
101102103104105106107108109110111112113114115
OPENOUTRAISERESETREVERSERUNSLOWSTARTSTOPSTOPTESTUPI(Int’lOn)O(Int’lOff)EMO
116117118119120121122123124125126127150151152
AUTO-MANCLOSE-OPENDOWN-UPFAST-SLOWFOR-REVHAND-AUTOHIGH-LOWJOG-RUNLEFT-RIGHTLOWER-RAISEMAN-AUTOOFF-ONON-OFFOPEN-CLOSERAISE-LOWER
201202203204205206207208209210211212213214215
REV-FORRUN-JOGRUN-SAFESAFE-RUNSLOW-FASTSTART-STOPSTOP-STARTUP-DOWN
216217218219220221222223
AUTO-MAN-OFFAUTO-OFF-MANCLOSE-OFF-OPENDOWN-OFF-SLOWFAST-OFF-SLOWFOR-OFF-REVLEFT-OFF-RIGHTLOWER-OFF-RAISEOFF-MAN-AUTOOFF-SLOW-FASTOFF-1-2OPEN-OFF-CLOSESLOW-OFF-FASTSUMMER-OFF-WINTERUP-OFF-DOWN1-OFF-2HAND-OFF-AUTO
301302303304305306307308309310311312313314315316317
1. Toorderengravednameplates,addlegendcodetonameplatepartnumber. Characterheightbasedonthenumberofcharactersandsizeofnameplate.Standardcharactersizeis3/16”.2. Nameplateswithstandardlegendsarethesamelistpriceasblanknameplates.
Nameplate Order Form on next page.
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
641800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Custom Engraved Nameplates Order Form — TW Series
CopythisorderformanduseittospecifyLetterHeight,CustomEngravings,LocationofEngravingonNameplate,andQuantityDesired.Toensureengravingaccuracy,faxittoyourIDECrepresentative.orDistributor.
YourCompanyName: _________________________________________
YourName: _________________________________________
Telephone: _________________________________________
Fax&Email: _________________________________________
IDECRep/DistributorContact:_________________________________
POnumber(ifknown):_________________________________
IDECRep/DistributorPhone:_________________________________
IDECRep/DistributorFax&Email:_________________________________
NWAL
EngravingLocation
Step 1. ChooseLetterSize-7/64”or1/8”.
Checktheboxforthelettersizeyouwant.Thenwriteyourletteringinboxbelowcheckboxes.Note:1/8”sizeletterscannotexceed9characters.
Step 2. SpecifyQuantity.
Qty
Enterthenumberofnameplatesdesiredintheboxontheright.
7/64” LetterSize
11charactersmax(for7/64”sizeletters)
Sample Letter Sizes
7/64”Letters:
1/8”Letters:
1/8” LetterSize
9charactersmax(for1/8”sizeletters)
1 2 3 4 5 6 7 8 9 10 11
NWAQL
EngravingLocation
Step 1. ChooseLetterSize-7/64”or1/8”.
Checktheboxforthelettersizeyouwant.Thenwriteyourletteringinboxbelowcheckboxes.Note:1/8”sizeletterscannotexceed9characters.
Step 2. SpecifyQuantity.
Qty
Enterthenumberofnameplatesdesiredintheboxontheright.
7/64” LetterSize
11charactersmax(for7/64”sizeletters)
Sample Letter Sizes
7/64”Letters:
1/8”Letters:
1/8” LetterSize
9charactersmax(for1/8”sizeletters)
1 2 3 4 5 6 7 8 9 10 11
NWAS
Engraving Location A
Engraving Location B
Step 1. ChooseLetterSize-1/8”or3/32”.
Checktheboxforthelettersizeyouwant.Thenwriteyourletteringinboxbelowcheckboxes.Note:1/8”sizeletterscannotexceed14characters.
3/32” LetterSize
20charactersmax(for3/32”sizeletters)
1/8” LetterSize
14charactersmax(for1/8”sizeletters)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Step 2. SpecifyQuantity.
Qty
Enterthenumberofnameplatesdesiredintheboxontheright.
Step 3. SpecifyLocation.
Location
Enterthelocationofengraving(AorB),intheboxontheright.
Sample Letter Sizes
3/32”Letters:
1/8”Letters:
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
642 www.IDEC.com
Switch Engraving Order Form – TW Series
CopythisorderformanduseittospecifyLetterHeight,MaximumNumberofLinesandTexttobeengraved.
Toensureengravingaccuracy,faxittoyourIDECrepresentativeorDistributor.
YourCompany: Telephone:
Name: Fax:
Address: Email:
PO: PartNumbertobeEngraved:
Pleasecheckoneoftheboxesbelowtoindicateyourchoiceofengravingoptions:
SquareSwitch
RoundSwitch
ø29mm, ø40mm Mushroom Head
Engraving Area 1
Engraving
Area 2†
# of Lines Letter Height
Max. Characters Per Line
# of Lines
Letter Height
Max. Characters Per Line
# of Lines
Letter Height
Max. Characters Per Line
15/32 6
15/32 5
Engraving Area 1 1
5/32 5
1/8 6 1/8 6 1/8 5
25/32 6
25/32 5
Engraving Area 2 1
5/32 7
1/8 5 1/8 6 1/8 7
3 1/8 6 3 1/8 5
4 3/32 5 4 3/32 5
1. Abovementionedspecificationsholdtrueforstandardsizepushbuttons(roundandsquare).2. †EngravingArea2canbeengravedfor40mmmushroomHeadnon-Illuminatedpushbuttononly.3. Engravingisdoneonthebuttonitselffornon-Illuminatedpushbuttonsandonmarkingplateforilluminatedpushbuttonsandpilotlights.4. Pleaseentertextexactlyhowyouwantitengraved,takecaretoemphasizecapitalorsmallletters.
Entertexttobeengraved:
Line1:
Line2:
Line3:
Line4:
Sample Letter Sizes
1/8Letters:
5/32Letters:
ForIDECInternalUseOnly:
WorkOrder#:
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
643800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Accessories
TW Series AccessoriesItem Appearance Description/Usage Part Number
LampRemovalTool RubbertoolusedtoinstallorremoveLED’sandincandescentlamps OR-55
ContactBlockRemover Usedtoremovecontactblocks,transformers,lenses,andadaptors.Canalsobeusedtodeterminepanelthicknessadjustment. TW-KC1
NutLockingWrench UsedinOR-14lockingwrenchtotightenlockingnutsinsidesquarebezel TW-KQ2
MetalBezel
Chromeplatedbezelstightenontooperator(replacementfordamagedbezels)
Standardoctagonalunits(chrome-pl.) AW-R8
Fullshroudoctagonalunits(chrome-pl.) AW-RF8
FullshroudmushroomheadunitsØ40mm AW-G4
PlasticBezel
Blackplasticbezelsforsquarebuttons(replacementfordamagedbezels)
Roundflushunits(blackplastic) AW-RP1B
Roundextendedunits(blackplastic) AW-FP1B
Squareunits(blackplastic) AW-Q1B
Squareunitswithfullshroud(blackplastic) AW-QF1B
Boot/Cover Usedtocoverandprotectpushbuttons
Waterprooflenscoverforsquarepilotlights APW00LN
Waterprooflenscoverforsquareilluminatedbuttons APW00L
Clearbootforroundflushunits OC-31
Clearbootforroundextendedunits OC-32
*Inplaceofasterisk,specifyRubber Boot color:B(black),G(green),R (red),Y (yellow)-(nitrilrubber) OCW-11*
Anti-RotationRing Ringtopreventoperatorbasefromrotatinginthemountinghole.Usedwhennameplateisnotused OGL-31
MountingHolePlug Blackrubberplugfillsunusedmountingholesinpanel. OB-31
MetallicMountingHolePlug
Forpluggingunusedmountingholesinthepanel.Tightentheattachedlockingringtoatorqueof12kfg-cmmaximumDegreeofprotection:IP66
LW9Z-BM
ReplacementKeys Pairofkeys(#0) TW-SK
ReplacementBlackSleeveforKeyswitch AKW2B-B
MetalButtonGuard Usedonflushbuttonstopreventinadvertentactuation OLW-C
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
644 www.IDEC.com
Item Appearance Description/Usage Part Number
TerminalTabAdaptor Quick-connectterminals #250(17/64”x3/64”)singletab TW-FA1
Lock-outAdaptor
Usedtoprovidelock-outprotectionforpushbuttonsandknobselectorswitches:•UptoØ40mmmushroomheadsize(Padlocknotincluded.)Notapplicablefore-stops.
HW9Z-KL1
TWtoTWTDAdaptor UsedtomountTWseriescontrolunit(exceptsquareunits)Ø7/8”(22mm)intoaØ1-13/64”(30mm)panelcut-out. TWN-A1R8
ReplacementMarkingPlates
Whiteplasticengravingplateforuseonallilluminatedunits(includedineachlens).Maybeusedtocaptureprintedmylarinsert(notsup-pliedbyIDEC)underlensface.
RoundPushbutton(Ø14mm) ALW2B
RoundPilotLight(Ø14mm) APW2B
MushroomPushbutton(Ø14mm) ALW3B
SquarePilotLight(q21mm) APQW1B
SquarePushbutton(q21mm) ALQW2B
Fingersafe Covers for TW SeriesAppearance Description Used with Part Number
Fingersafeterminalcover,adds6mmtooveralldepth APWandUPQWfullvoltagepilotlights APS-PVL
Fingersafeterminalcover,adds3.5mmtooveralldepth.Onerequiredforeachcontact,onlyforrear-mostterminals
Non-illuminatedpushbuttonsandselectors HW-VL2
Fingersafeterminalcover,adds3mmtooveralldepth APWandUPQWtransformerpilotlights,andillumi-natedpushbuttonsandilluminatedselectors HW-VL3
Fingersafeterminalcoverforcontacts. Fullvoltageilluminatedpushbuttonsandselectors HW-VL4
Fingersafeterminalcoverforfullvoltageadaptor,adds3mmtodepth Fullvoltageilluminatedpushbuttonsandselectors HW-VL5
Fingersafeterminalcoverforhalfsizetransformeradaptor,adds3mmtodepth Illuminatedpushbuttonsandselectors HW-VL6
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
645800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Dimensions
Pushbuttons
Flush Extended Extended with Full Shroud
30
37ø29
ø24
13
M3.5 TerminalScrews
68.5 (3-4 blocks)
48.5 (1-2 blocks)
Panel Thickness 1 to 6
13
19 30
37ø29
ø24
M3.5 TerminalScrews
68.5 (3-4 blocks)
48.5 (1-2 blocks)
Panel Thickness 1 to 6
ø29
30
37ø24
19.5
M3.5 TerminalScrews
68.5 (3-4 blocks)
48.5 (1-2 blocks)
Panel Thickness 1 to 6
29mm Mushroom 40mm Mushroom Mushroom with Full ShroudM3.5 TerminalScrews
13
22.568.5 (3-4 blocks)
48.5 (1-2 block)
Panel Thickness 1 to 6
30
37ø29
M3.5 TerminalScrews
1322.5
ø40
68.5 (3-4 blocks)
48.5 (1-2 blocks)
Panel Thickness 1 to 6
30
37
M3.5 TerminalScrew
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness 1 to 6
30
37ø46
23
29mm Push-Lock-Turn-Reset 40mm Push-Lock-Turn-Reset Keylock Push On/Off
30
37
1322.5
ø29
M3.5 TerminalScrews
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness1 to 6 Reset Angle 75°
M3.5 TerminalScrews
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness1 to 6 Reset Angle 75°
30
37
13
22.5
ø40
Reset(unlock)
37
2547
13
ø29
45°
30
M3.5 TerminalScrews
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness1 to 6
40mm Pushlock Key reset 40mm Push-Pull Square Flush
(unlock)Reset
37
25
47
13
45°
30
ø40
M3.5 TerminalScrews
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness1 to 6
37
2513
30
ø40
30.5
M3.5 TerminalScrews
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness1 to 6
37
13
30
30 25
M3.5 TerminalScrews
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness1 to 6
Square Extended
37
1330
30
20
25
M3.5 TerminalScrews
48.5 (1-2 blocks)
68.5 (3-4 blocks)
Panel Thickness1 to 6
Selector Switches
37
2513
30
ø24
ø29
M3.5 TerminalScrews
48.5 (2 blocks)
68.5 (4 blocks)
Panel Thickness 1 to 6M3.5 TerminalScrews
48.5 (2 blocks)
68.5 (4 blocks)
Panel Thickness 1 to 6
37
1330
ø29
ø25
25
M3.5 TeminalScrews
48.5 (2 blocks)
68.5 (4 blocks)
Panel Thickness 1 to 6
37
13
30
ø29
19
41
ø24
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
646 www.IDEC.com
Dimensions continued
Illuminated Pushbuttons
Extended Extended with Full Shroud Square Extended
Marking plate: ø15.5mm
Panel Thickness1 to 6
13
19 30
ø24
ø29 37
Marking plate: ø15.5mm
Panel Thickness1 to 6
30
ø24
ø29 37
20 30
37
20
13
25 30
Marking plate: 21mm
Panel Thickness1 to 6
29mm Push-Turn-Reset 40mm Push-Turn-Reset Mushroom
Marking plate: ø13.9mm
Reset Angle: 75°Panel Thickness1 to 6
30
37
13
22.5
ø29
Marking plate: ø13.9mm
Reset Angle 75°
30
37
13
22.5
ø40
Panel Thickness1 to 6
Marking plate: ø13.9mm
30
37
13
ø29
22.5
Panel Thickness1 to 6
Push-Pull
Marking plate: ø13.9mm
Panel Thickness1 to 6
30
37
25
13
ø40
30.5
Illuminated Selector Switches
1 Contact Block with Full Voltage Adaptor Transformer (2 blocks) 1 Contact Block with Half Size Transformer
X2X1
X2
X1
M3.5 Terminal Screws Panel Thickness1 to 6
86.5
X2
X1
64.5
Panel Thickness1 to 6
2 Contact Blocks with Full Voltage Adaptor Transformer (4 blocks) 2 Contact Blocks with Half Size Transformer
X1
X2
63.5
M3.5Terminal Screw Panel Thickness
1 to 6mmX2
X1
106.5
M3.5 Terminal Screws Panel Thickness1 to 6
X2
X1
68.5
Panel Thickness1 to 6
3 Contact Blocks with Full Voltage Adaptor 4 Contact Blocks with Full Voltage Adaptor 3 Contact Blocks with Half Size Transformer
X2X1
68.5
M3.5Terminal Screws Panel Thickness
1 to 6 X1
X2
X2
X1
84.5
M3.5 Terminal Screws
Panel Thickness1 to 6
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
647800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Dimensions continued
Pilot Lights
Round Flush APW1 Full Voltage Round Flush APW1 Transformer
28.5 13 30
ø29 37ø24
17
Panel Thickness1 to 6
28.5 13
66.5
30
ø29 37ø24
17
M3.5 Terminal Screw
Panel Thickness1 to 6
Round Flush Marking Type APW1B Full Voltage Round Flush Marking Type APW1B Transformer
Marking plate: ø15.5 mm
28.5 13 30
ø29 37ø24
17
Panel Thickness1 to 6
Marking plate: ø15.5 mm
28.5 13
66.5
30
ø29 37ø24
17
M3.5 TerminalScrew
Panel Thickness1 to 6
Dome APW2 Full Voltage Dome APW2 TransformerPanel Thickness1 to 6
28.5 13
25
30
ø23
.6
ø29 37
M3.5 TerminalScrew
Panel Thickness1 to 6
28.5 13
66.5 25
30
ø23
.6
ø29 37
Square Flush Marking Type APQW1B Full Voltage Square Flush Marking Type APQW1B Transformer
Marking plate: 22 mm
Panel Thickness1 to 6
28.5 13 30
37
16
25 30
Marking plate: 22 mm
M3.5 TerminalScrew Panel Thickness 1 to 6
28.5 13
66.5
30
37
16
25 30
Illuminated Selector SwitchesM3.5 Terminal Screws
83.5 (4 blocks)
B: 86.5 (2 blocks), 106.5 (4 blocks)
A: 63.5 (2 blocks)
Panel Thickness 1 to 6
13
25
ø24
ø29
30
37
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
648 www.IDEC.com
Dimensions continuedPanel Cut-Out
Diagram PartDimension
A B C D
A
B
D
C
Pushbuttons
Ø0.137”(3.5mm)
1.95”(50mm);1.76”(45mm)minimum
Ø0.878”(22.3mm)
1.17”(30mm)Std.Octagonal
>1.56”(40mm)LargeMushroom
Pilot Light
Illuminated Pushbuttons
Selector Switches1.17”(30mm)*Seenote.
Illuminated Selector Switches
1.TheØ0.137”(Ø3.5mm)recessisnecessarywheneitherthenameplateoranti-rotationringisused.2.*>1.404”(36mm)for2-or3-position. >1.95”(50mm)for4-or5-position.
Accessory Dimensions
OGL-31Anti-Rotation Ring
OLW-CMetal Button Guard
OCW-11Pushbutton Rubber Boot
OB-31Mounting Hole Rubber Plug
ø22 ø27.4
10.2
0.8ø22.5
18.6
1.6t
R42.5
Mou
ntin
g Ce
nter
s50
min
.
15
Flush
M22 P1.0
ø31
18.5
ø32
9
Extended
M22
Buttoninstalled
Buttoninstalled
P1.0
ø32
9
ø26
ø31
21
ø29
ø25 3.5
3.5
HW9Z-KL1Lock-out Adaptor
AW-RP1BRound Plastic Bezel
AW-FP1BRound Plastic w/Full Shroud
Key hole ø8Waterproof RubberGasket 0.5t
3070
ø50
(ID: ø44.4)
93
29.530
R66.5
Panel Thickness0.8 to 3.2
82.5
ø22.2
24 (inside)
ø29
13
ø29
19.8
AW-QF1BSquare Full Shroud
30
13
Finger-Safe Cover Dimensions
HW-VL6 HW-VL5 HW-VL4
HW-VL3 HW-VL2 APS-PVL
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
649800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Component Construction and General Instructions — TW Series
Instructions for Switches and Pilot Devices
TWSeries:AdjustmentforPanelThickness
Thepanelthicknessringprovidesadjustmentfrom0.04”to0.24”(1to6mm)in0.004”(0.1mm)increments.Rotatetheringuntilthemarkingsaroundtheperipheryarealignedforthedesiredthickness,asshownbelow.
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0
Scale on Adjustment (in 0.1 mm)
0.1 mm
12
4
6
3
5
1 mm Panel Thickness Scale(in 1 mm on the operator)
A
35
435
46 6
2
Ex. Panel thickness 2 mm Ex. Panel thickness 2.6 mm
Note: Whenanameplateorananti-rotationringisused,add0.03”(0.8mm)tothepanelthicknessdimension.
Anadjustmentforpanelthicknessesshownbelowcanbemadequicklybyusingthecontactblockremovertool.
1.6 mm
2.3 mm
3.5 mm
1 mm2 mm
3.2 mm
Tool TW-KC1
Switc
hes
& P
ilot D
evic
esSi
gnal
ing
Ligh
tsRe
lays
& S
ocke
tsTi
mer
sCo
ntac
tors
Term
inal
Blo
cks
Circ
uit B
reak
ers
ø22mm - TW Series Switches & Pilot Devices
650 www.IDEC.com
Instructions continued
Pilot Lights and Pushbuttons
IMPORTANT:InstallthebodyoftheTWcontrolunitwiththepanelthicknessscalefacingup.
Octagonal and Round Bezels
Octagonalandroundbezelsscrewintotheoperator.Usealockingringwrench(optional)forsecuretighteningandeasyremoval.Roundflushandextendedbuttonssnapontotheoperatorbase.Mushroombuttonsscrewontotheoperatorbase.
Everyroundlenscanbeusedwithorwithoutlegendmarkings.Engravingcanbedoneonawhitetranslucentplatewhichisplacedinthelens,orclearmylarcanbeprintedandplacedinthelens.
Round Marking Unit
Insertmarkingplateunderlens
Lens
MarkingPlate
Press in
Pressinroundflushandextendedlens.Screwinmushroomlens
Square Bezels
Squarebezelsareinstalledina3-stepprocedure.Firstinstallthebaseplatefromthefront.Theninstallthelocknutusingthenutlockingwrench(optional).Finally,installthesquarebezel,whichsnap-fitsontothebaseplate.Squarebuttonsalsosnapontotheoperatorbase.
Everysquarelenscanbeusedwithorwithoutlegendmarkings.Engravingcanbedoneonawhitetranslucentplatewhichisplacedinthelens,orclearmylarcanbeprintedandplacedinthelens.Squareunitsincludearoundwaterprooflenswhichscrewsintotheoperator.Thesquareouterlenssnapson.
Square Marking Units
Insertmarkingplateunderlens
PilotLight
Marking PlateInse
rt
Squa
re L
ens
Insertmarkingplateunderlens
IlluminatedPushbutton
Marking Plate
Lens Retainer
Waterproof Lens
Pres
s in
Squa
re L
ens
Toremovesquarelensfromoperator,placeascrewdriverundertheindentationonthesideofthelens.Toremovethemarkingplate,placeascrewdriverundertheindentationandliftouttheplate.Thelensretainercanberemovedbypressinga3/16”screwdriverintooneoftherecesses.
Marking Plate Engraving Area
Shape Engraving Area Used With Part Number
RoundØ0.55”(14mm) Illuminatedpushbuttons ALW2B
Ø0.55”(14mm) Pilotlights APW2B
Mushroom Ø0.55”(14mm) Illuminatedmushroom ALW3B
Square q0.83”(21mm) Squarepilotlights APQW1B
Square q0.83”(21mm) Squareilluminatedpushbuttons ALQW2B
Switches &
Pilot Devices
Signaling LightsRelays &
SocketsTim
ersContactors
Terminal Blocks
Circuit Breakers
651800-262-IDEC (4332) • USA & Canada
ø22mm - TW SeriesSwitches & Pilot Devices
Instructions, continued
Selector Switches
Theoperatorshaftofeachunithasarecesstoidentifyinwhichdirectiontoinstallthehandle.Alignthehandlewiththerecess.Presscolorinsert(TW-HC1)intothehandleandthenpresshandleintotheoperator,asshownbelow.
Selector Switch(non-illuminated)
IlluminatedSelector Switch
Recess
Pressincolorinsert
Pressinhandle
Removecolorinsertbeforepullingoutthehandle.
Standard Operating Positions2-Postion, 90º 3-Postion, 45º 4-Postion, 45º 5-Postion, 30º
1 2 1 2
01
23
41
2 3 45
Positions: Non-Illuminated 3-Position Operators
1 20 1
2
0
1
2
0
Installation
TerminalX1=PositiveTerminalX2=Negative
Makesureslotisfacingup
Lampholderisinstalledasshown,duetopolarity.Leadholder(usedwithtwostacksofcontactblocks)doesnothavepolarity.
TWIlluminatedPushbuttons,TWSelectorSwitches(ACTransformerorFullVoltage)
TW Pilot Lights
Installation of LED Illuminated Units
ACtransformersarerecommendedforuseinareassubjectedtoinductivenoise.Whenusingfullvoltagetypes,installaprotectiondiodeasshownbelow.(DiodewithDCpowersupplytoprotectagainstsurgesandnoise.)
TerminalX1
TerminalX2
Diode
LED
MakesurethatLEDilluminatedunitsareinstalledwithcorrectpolarity,asindicatedattheterminals.