easy connect LEDand
easy connect LEDplus Shaft lighting
Systems
We light with LEDs!
Prepared by:Switch GmbH & Co. KGBorsigstr. 1730916 IsernhagenGermany The information has been summarised in all conscience, errors and omissions excepted.
2
Content
Regulatory standards
Comparison shaft lighting
easy connect LED shaft lighting
easy connect LEDplus shaft lighting
easy connect LEDplus shaft lighting control system
3
European regulation
The European safety rules are fixed in the European standard EN 81-20.:
Safety rules for the construction and installation of lifts
– Lifts for the transport of persons and goods –
Part 20: Passenger and goods passenger lifts
This European standard is valid in all CEN*-Nations:
Belgium, Bulgaria, Denmark, Germany, Croatia, Serbia, Bosnia-Herzegovina,
Macedonia, Estonia, Finland, France, Greece, Ireland, Island, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Austria, Poland, Portugal,
Romania, Sweden, Switzerland, Slovenia, Slovakia, Spain, Czech Republic,
Turkey, Hungary, United Kingdom and Cyprus
CEN* - Comitté Européen De Normalisation
4
European regulation, regular shaft lighting according to EN 81-20.
5.2.1.4 Lighting
5.2.1.4.1 The well shall be provided with permanently installed electric lighting, giving the following intensity of illumination, even when all doors are closed, at any position of the car throughout its travel in the well:
1. a) at least 50 lx, 1.0 m above the car roof within it's vertical projection;
2. b) at least 50 lx, 1.0 m above the pit floor everywhere a person can stand, work and/or move between the working areas;
3. c) at least 20 lx outside of the locations defined in a) and b), excluding shadows created by car or components.
To achieve this, sufficient number of lamps shall be fixed throughout the well and where necessary additional lamp(s) may be fixed on the car roof as a part of the well lighting system.
5
European regulation, emergency shaft lighting according to EN 81-20.
5.4.10.4 Emergency Lighting
There shall be emergency lights with an automatically rechargeable emergency supply, which is capable of ensuring a lighting intensity of at least 5 lx for 1 h:
1. a) at each alarm initiation device in the car and on the car roof;
2. b) in the centre of the car 1 m above the floor;
3. c) in the centre of the car roof, 1 m above the floor.
This lighting shall come on automatically upon failure of the normal lighting supply.
6
European regulation, ICEL 1006
ICEL 1006: Emergency Lighting Design Guide
This guide has been prepared by the Industry Committee for Emergency Lighting (ICEL). It provides information for the use of emergency lighting design engineers to promote a wider understanding of the different types of emergency lighting, and gives guidance on their correct application.
This standard was developed from the ICEL Guide 1006, which gave guidance to theapplication of BS 5266-1 and considers the requirements of the new European draft standards as well as the current legislation and codes of practice.ICEL recommends that emergency lighting is designed and installed to the new standard.
7
ICEL 1006, Terminology
For the purpose of the British and European standard BS EN 1838, Emergency Lighting is the generic term for equipment that provides illumination in the event of failure of supply to normal lighting. There are number of specific forms as shown in the figure below.
8
ICEL 1006, Illuminance requirements
A lift is seen as an additional area, where in the past no illumination was specified.This has been changed with the current version.
9
Switch GmbH & Co. KG, easy connect LED, Comparison of shaft lighting solutions
Common illumination Illumination with easy connect LED lighting strip
The Switch GmbH & Co. KG LED-shaft lighting solutions exceed the standards and recommendations by far, as an equal illumination is provided along the whole shaft.The illuminance requirements are exceeded in all cases.
Illumination with easy connect 2 fluorescent tubes
11
easy connect LED,Technical data
Power supply: 220 - 240 VAC
Number of LEDs: 60 LEDs per meter
Angle of radiation: 120 deg
Colour temperature: 4000 – 4500 K
Lumen per meter: > 1200
Vertical illuminance (average): 80 lx (1 m above car top), approved by DEKRA
Power consumption: < 8 W / m
Weight of the LED-strip: 115 g/m
Dimension of the LED-strip (width x height): 14 mm x 7 mm
Protection class: IP65 (IP68 optional)
12
Switch GmbH & Co. KG, easy connect LEDplus, Comparison of operation
Emergency shaft lightingeasy connect LEDplus,seen from the pit
● 2 separate electric circuits for regular shaft lighting (230 VDC) and emergency light (24 VDC)
● Each 10th LED is connected to the emergency path ● Power supply of the emergency light is 24 VDC, 12 VDC optional
Common shaft lightingeasy connect LEDplus,seen from the pit
Emergency shaft lightingonly on top of the cabin,seen from the pit
13
easy connect LEDplus,At a glance● The LEDplus shaft lighting consists of a robust PVC LED-strip,
a connection box with rectifier and a 10 m power supply cord with shaped plug and 2 cable clamps for the emergency light
● The flexible LED-strip is equipped with high luminance LEDs ● The large beam of the LEDs provides an equal illumination
along the shaft without horizontal formation of shades● Emergency light along the complete shaft providing more
safety for service technician in the pit and on the car top● Emergency light exceeding EN81-20. 5.4.10.4c● One continuous strip from the pit up to the bottom of the shaft,
maximum length 50 m● Easy installation with 6 mm plastic dowels. The recommended
distance between the dowels is 2 to 3 m ● Fast installation (approx. half an hour at 22 m shaft height)
and light right from the beginning● IP65 protection with safety class II● Self extinguishing burning characteristic● Semiconductor protection of stress peaks at the rectifier
14
easy connect LEDplus,Technical data
Main power supply: 220 - 240 VAC
Emergency power supply: 24 VDC (optional 12 VDC)
Normal light: 54 LED per meter
Emergency light: 6 LED per meter
Angle of radiation: 120 deg
Colour temperature: 4000 – 4500 K
Lumen per meter (standard light): > 1200
Vertical illuminance (average): 80 lx (standard light, 1 m above car top)
5 lx (emergency light, 1 m above car top)
Current consumption of emergency light
LED-strip: 30 mA / m; max 1 A / 50 m
Weight of the LED-strip: 145 g/m
Dimension of the LED-strip (width x height): 18.5 mm x 9 mm
Protection class: IP65 (IP68 optional)
15
easy connect LEDplus,Shaft lighting control system● Includes the necessary electronic system for the operation of the LED shaft lighting as
well as the independent operation of the emergency light function. ● It monitors continuously the main power supply and will switch immediately to the
emergency light in case of a breakdown of the main power.● The maximum operating time of the emergency light is depending on the height of the shaft respectively the length of the LED-strip. ● The box includes the rechargeable batteries, the charging unit and the fuse for the
plug socket of the pit bottom box.
16
easy connect LEDplus,Shaft lighting control system, technical data
Terminals
Input power: 230 - 240 VAC
Output power (shaft-lighting): 230 - 240 VDC
Output power (emergency light): 24 VDC
Duration of the emergency light: > 2 hours
Material of the box: Polysterene
Housing protection class: IP66
Temperature range: -20°C to +60°C
Weight: approx. 4.1 kg
Dimensions (Width x Height x Depth): 255 x 180 x 110 mm
Fuse of plugsocket/pit bottom control box: 10 A
17
2 functions: - Light push button - Schuko socket outlet
3 functions: - Light push button- Schuko socket outlet- Emergency stop button
Pit bottom control boxes:
4 functions: - Light push button- Schuko socket outlet- Emergency stop button- Alarm push button
18
- Push button for light control (incl. latching relay) - Socket for connection of shaft lighting 230 VAC - Return light
- As above but with terminls for additional Shaft light buttons
Engine room control box:
2 functions: - Light push button - Schuko socket outlet
3 functions: - Light push button- Schuko socket outlet- Emergency stop button
Pit bottom control boxes:
4 functions: - Light push button- Schuko socket outlet- Emergency stop button- Alarm push button
Switch LED-shaft lighting solutions Conclusion
● easy connect LED-shaft lighting provides an equal illumination in the shaft right from the beginning.
● easy connect LED-shaft lightings are designed for fast and easy installation
● easy connect LEDplus-shaft lighting provides additionally an emergency light along the shaft exceeding EN81-20.5.4.10.4c
● The Switch shaft lighting control unit includes all components to operate the easy connect LEDplus-shaft lighting independently from any other elevator control system