12
Surgical Product Focus Edition 2

Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

Surgical Product FocusEdition 2

Page 2: Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

Paragon Care has acquired eleven companies over the past seven years. Each one a leading provider of innovative healthcare equipment and consumables. Through these acquisitions we have now established offices and warehouses across Australia, with Head Office based in the eastern suburbs of Melbourne.

Designs For Vision have been a specialist provider of diagnostic and surgical products to the ophthalmic and optometry sector for over 40 years. Using a global network Designs For Vision sources the highest quality products and are currently representing over 50 global companies to a wide range of medical and para-medical disciplines.

Designs For Vision has a strong focus on education and the provision of training to support the products, this includes providing education support for Ophthalmologists, Optometrists, Ophthalmic Nurses, Orthoptists and Dentists.

Designs For Vision also have its own surgical and diagnostic product ranges, which are designed and manufactured in Australia and exported through their network of global contacts.

Paragon Care has emerged as a leading provider of equipment, devices and consumables to the healthcare market.

Health. Covered.

Page 3: Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

Hydrophilic acrylic injectable IOLs for post-operative refractive correctionRayner Sulcoflex Pseudophakic Supplementary IOLs are designed to be implanted in the ciliary sulcus to correct any residual post-operative refractive errors following the implantation of a conventional IOL in the capsular bag*.

Indications – Post-surgical ametropia

– Enhancement of the refractive result after RLE or PRELEX

– Enhancement of near / far vision

– Correction of pseudophakic presbyopia

– Correction of residual pseudophakic astigmatism

– Extreme myopia or hyperopia

– Patients experiencing a dynamic change of refraction

– For the refractive correction of patients without biometry readings

– Reversible

Reduced surgical risk associated with IOL exchange – Less surgical trauma than primary IOL exchange

– Avoids sometimes difficult removal of fibrosed, fixated primary implant.

Avoids the potential problems of conventional “piggy-back” IOLs – Unique posterior concave surface, minimises the possibility of interaction

with the primary IOL

– Reduced likelihood of unwanted photopic effects

– Reduced refractive error with hyperopic defocus.

* An iridotomy/iridectomy may be necessary

RAYNER Sulcoflex® Pseudophakic Supplementary IOLs

Intraocular Lenses

Sulcoflex Aspheric (653L)Standard Power Range: -5.0 to -0.5D, +0.5 to +5.0 DMade to Order: -10.0 to -5.5D, +5.5 to +10.0 D

Sulcoflex Multifocal (653F)Standard Power Range: -3.0 to +3.0 DMade to Order: -7.0 to -3.5D, +3.5 to +7.0 D

Sulcoflex Toric (653T)Standard Power Range: Sphere: -3.0 to +3.0 D, Cyl: +1.0 D, +2.0 D, +3.0 DMade to Order: Sphere: -7.0 to +7.0 D, Cyl: +1.0 to +6.0 D

Sulcoflex Multifocal Toric (653Z)Standard Power Range: Sphere: -3.0to +3.0 D, Cyl: +1.0 D, +2.0 D, +3.0 DMade to Order: Sphere: -7.0 to +7.0 D, Cyl: +1.0 to +6.0 D

1. Physical contact between the two IOLs minimised.

1

Page 4: Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

Intraocular Lenses

1-piece aspheric IOL with new hydrophobic Vivinex™ acrylic

According to in vitro tests, the new acrylic polymers properties of Vivinex™ drastically reduce glistening and PCO

Easy to insert through an incision as low as 2.0 mm

The Vivinex iSert Model XY1 is a single piece aspheric IOL with a yellow tinted optic manufactured from the new hydrophobic material Vivinex™

The ergonomically-designed iSert® system provides highly predictable, reproducible IOL delivery through a very small incision

– New iSert® offers easy handling and a better surgical comfort

– Very small incision size reduces the risk of surgically-induced astigmatism

Distinctive IOL design• Very sharp edge• Textured optic edge and textured-rough haptics• Aspheric ABC Design• Low PCO rate*

• Long term transparency based on in vitro tests**

* Japanese clinical study carried out in 2010: internal report

** Internal test results, HOYA data

*** The A Constant mentioned above is presented as a guideline only for lens power calculations.

It is recommended that the A Constant measurement be customiswed based on the surgeon’s

experience and measuring equipment.

1. Nishi O, Nishi K, Akura J. Speed of capsular bend formation at the optic edge of acrylic, silicone, and poly(methyl methacrylate) lenses. J Cataract Refract Surg 2002; 28(3):431-437.

2. Meacock W, et al. The Effect of Texturing the Intraocular Lens Edge on Postoperative Glare Symptoms.

3. Data on file: in vitro test achieved according to published method: Marrie van der Mooren et al. “Effects of glistening in intraocular lens”, BIOMEDICAL OPTICS EXPRESS, vol 4, No.8, P1294-1304(2013).

HOYA Vivinex Mode XY1

Textured-rough Haptic

– Better grip onto capsular surface is expected

– to avoid the haptic-tip sticking to the optic when folded

Improved Square Edge

– Very sharp edges

– Helps to prevent PCO1

Optical Edge Textured Finish

– To reduce Dysphotopsia2

Reduced Glistenings

– The innovative hydrophobic material Vivinex™ is associated with a significant decrease in glistening

– No glistening was seen based on in vitro testing (35ºC to 23ºC)3

Model Name VivinexTM iSert® XY1

Optic Design Aspheric ABC Design with sharp textured optic edge

Optic & Haptic Materials Hydrophobic acrylic Vivinex™ with blue light filtering

Haptic Design textured-rough haptic surface

Dimension (Optic/OAL) 6.0 mm /13.0 mm

Power +6.0 to +30.0 D (in 0.5D increments)

Estimated A-Constant 118.9***

Incision size as low as 2.0 mm

Page 5: Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

MORCHER Capsular Tension Rings

Implantable Capsular Tension Rings A necessity to have available for modern cataract surgery, Morcher CTR’s are manufactured from one-piece PMMA and stabilise the capsule in the case of damaged or missing zonules.

Easily implantable with all available injector systems or forceps and now with the new Pre-Loaded Eyejet System on a Disposable Injector, Morcher offer the most comprehensive range for capsular bag stabilisation.

Advantages – circular expansion of the capsular bag

– stabilisation of the capsular bag

– with small zonula damage, no scleral fixation is necessary

– reduces the risk of damaging the capsule or zonules during surgery

– better centering of the IOL, also in cases of future capsular bag shrinkage

– simplifies the implantation of foldable IOLs

– Type 13 - curved leading arm further reduces risk of damaging zonules and capsule during surgery

Type 14

Type 13

Type 14C

Type 13A

Type 14A

Type 13B

Capsular Tension Rings

Type 14 Type 13

Code Description

Pre-Loaded CTR’s

MORCHER-190* EyeJet Preloaded Type R14 CTR, 10mm

MORCHER-198* EyeJet Preloaded Type R14C CTR, 11mm

MORCHER-194* EyeJet Preloaded Type R14A CTR, 12mm

MORCHER-060 EyeJet Preloaded Type R13 CTR, 10mm

MORCHER-064 EyeJet Preloaded Type R13A CTR, 11mm

MORCHER-068 EyeJet Preloaded Type R13B CTR, 12mm

Standard CTR’s

MORCHER-202 Type 14 CTR, 10mm

MORCHER-206 Type 14C CTR, 11mm

MORCHER-204 Type 14A CTR, 12mm

MORCHER-050 Type 13 CTR. 10mm

MORCHER-052 Type 13A CTR. 11mm

MORCHER-054 Type 13B CTR. 12mm

Page 6: Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

DUCKWORTH & KENT Titanium Instruments

Why Duckworth & Kent Titanium? In 1972 Duckworth & Kent became the original manufacturer of Titanium surgical instruments for ophthalmology.

Still manufacturing in Baldock England, Duckworth & Kent’s product range comprises of more than 1,800 titanium instruments.

Commitment to investment has seen D&K progress into a high technology, precision engineering operation utilising the very latest technology available.

Today Duckworth & Kent is regarded as one of the pioneers and a world specialist in manufacturing from Titanium, producing the finest quality ophthalmic surgical instruments on the market.

Titanium offers advantages such as no oxidation, non magnetic, lightweight, and yet extremely durable.

What are the benefits for the surgeon? – The metal’s lightness is a positive aid to reducing any fatigue of the

surgeon.

– Instruments are anodised to provide a non reflecting surface, essential in microsurgical operations.

– Titanium instruments withstand repeat sterilisation without compromise to edge or surface quality, corrosion resistance or strength.

– Titanium is non magnetic, and therefore does not cause adverse reactions with other steel instruments or equipment. shrinkage

Duckworth & Kent titanium instuments offer surprising value for money. Contact us for a quotation.

30% off ALL D&K instruments until end December 2016Quote reference “DK30promo2016” on order

Basic Cataract Set

Ophthalmic Surgical Instruments

DK-2-719N Utrata Capsulorhexis Forcep

DK-2-522N Kelman McPherson Forceps

DK-6-496-2 Drysdale Paddle/Rotator

SET PRICE $1,100 +GST*

PST Sterilising TrayORMatbox Instrument Tray

DK-9-556 Kratz-Barraquer open wire temporal speculum

H-4010 Drape/Iris scissors

2525

Page 7: Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

Code Description

DK-6-085-1 Barrett Duo Nucleus Rotator / Manipulator / Splitter

DUCKWORTH & KENT Capsulorhexis Forceps

D&K New Style Vannas Scissors

D&K Barrett Duo Nucleus Rotator / Manipulator / Splitter

Ophthalmic Surgical Instruments

DK-2-2-716G-9R Calladine-Inamura Capsulorhexis Forceps

– 2.5 & 5mm marks to assist in rhexis sizing

– Down to 1.8mm incision

– Three pivot point precision for a smooth controlled action.

2.5mm

5mm10mm

1.5mm

0.9mm

Code Description

DK-2-2-716G-9R Calladine-Inamura Capsulorhexis Forceps

DK-2-847-4 Micro Capsulorhexis Forceps Squeeze Handle

– Fine pointed tips with platforms

– Curved 23 gauge tube

– Down to 1.0mm incision

Code Description

DK-2-847 Micro Capsulorhexis Forceps Squeeze handle

1-110N Vannas Scissors (straight)New style Vannas with ergonomic handle for precision and comfort

– harp tips, straight blades

– Cut length 5mm, tip to pivot length 9mm

– Flat handle, length 109mm

DK-6-085-1 Nucleus splitter – tip length 1.25mm, Cutting Edge 60° to Axis Rotator / Manipulator

– 0.65mm mushroom tip

Code Description

DK-2-847 Vannas Scissors (straight)

Page 8: Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

9-840 Cionni Pre-op Toric Reference Marker- 3 blades, radial marks- 10mm inside diameter, 15mm outside diameter- 70° angled shaft- Round handle, length 124mm

9-705R-1 Mendez Intra-op Degree Gauge- Measures 0° - 180°- 5° increments marks- Internal gauge diameter 12.0mm- External gauge diameter 14.0mm- 60° angled handle- Round handle, length 103mm

9-729-1 Axis Intra-op Marker- Two blades with centre pointer- 4.0mm inside diameter, 11.6mm outside diam.- Round handle, length 95mm

DUCKWORTH & KENT Toric Markers

Toric Markers

Titanium surgical instruments for alignment of toric IOLs

Marks Created

Marks Created

Code Description

Duckworth & Kent Toric Markers

DK-9-840 Cionni Toric Reference Marker

DK-9-705R-1 Mendez Degree Gauge

DK-9-729-1 Axis MarkerOther toric markers also available, including markers for small eyes - call for details.

TORIX® Toric IOL Marking and Alignment System

Single Use Toric IOL Marking and Alignment System – Better, highly visual, corneal marks - vertical and horizontal

(proprietary marker edge treatment)

– Easy-to-use and align

– Cost effective

– Immediately ready for every Toric IOL case

– No cleaning or sterilising costs

– Supplied 10 per box

Code Description

TORIX Torix Marking system

Page 9: Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

VISCOT Surgical Skin Markers

Scrub Resistant Ink • Quality Tips • Latex FreeMedical skin and tissue markers for marking prior to surgical incision. Particularly relevant for marking orientation of toric IOLs on the eye prior to implantation.

– Sterile, Single use

– Markings will disappear naturally with bathing in a few days.

Code Description

Viscot Surgical Skin Markers

1436SR-10 Value Surgical skin Marker Ultra Fine/Regular Tip, Sterile

1436SR-100 Value Surgical skin Marker Ultra Fine/Regular Tip, Sterile

1437SR-10 Value Surgical skin Marker Fine/Regular Tip ,Sterile

1437SR-100 Value Surgical skin Marker Fine/Regular Tip, Sterile

1400-100 Viscot Precision Surgical Skin markers Fine/Reg, Sterile

1402-100 Viscot Precision Ultrafine Tip, with Ruler, Sterile

1425SR-10 Twin Tip Skin Marker with Ultra Fine/Regular Tip, Sterile

1425SR-100 Twin Tip Skin Marker with Ultra Fine/Regular Tip, Sterile

1404-10 Precision Surgical Skin Marker Broad/Utility Tip w/ruler, Sterile

1451SR-10 Surgical Skin Marker with Fine/Regular Tip, Sterile

1460SRL-10 Standard Surgical Skin Marker Fine/Regular Tip

1460SRL-100 Standard Surgical Skin Marker Fine/Regular Tip

ALBERT HEISS IOL Removal Set

H-6357 IOL Holding Forceps – Secure holding of the lens while cutting

– Fragments easily removed thanks to the special shape of the jaws

– Jaw length: 11mm, shaft diameter 1.2mm

H-6420 IOL Cutting Scissors – Grooves on the lower cutting blade so the lens does not slide

while cutting

– Efficienty cutting thanks to strong and sharp blades

– Blade length: 8 mm, shaft diameter 1.8mm

Code Description

H-6357 IOL Holding Forceps

H=6420 IOL Cutting Scissors

Page 10: Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

CLINIPAK Point Protectors

Plastic Point and Needle Protectors Transparent point protectors protect the tips and points of specific instruments and facilitate their visual identification. The unique design minimises the movement of instruments and holds them open to strengthen their subsequent sterilisation.

Plastic Point Protectors are manufactured from colourant-free Polypropylene. This product is totally chlorine-free (TCF), contains no CFC and does not release harmful chemicals when burned.

– Transparent Plastic Point Protectors are single-use only products.

Code Description

CPPT007C Point Protector Polyprop 15Mm Transparent (Bx 200)

CPPT008C Point Protector Polyprop 30Mm Transparent (Bx 200)

Honan-Balloon IOP Reducer

Matbox Instrument Tray

The Honan-Balloon is available for precise IOP reduction.

The Matbox is both a box for sterilising surgical instruments and a mat with spikes. Designed to be used as protection for tools, instruments and surgical accessories during the sterilisation cycle in hospitals Integrated spikes, up and down, ensure the holding of medical instruments once the Matbox is closed.

– Secure closing

– Eases transportation

– Practical for simple instrument sterilisation

– Flexible and compact

– Steam autoclave and ethylene oxide sterilisation safe

Sterilising: Can be sterilised via the following two methods: 1) Autoclave according to the validated protocol in the hospital 2) Ethylene oxide according to the validated protocol in the hospital

Code Description

HB2055 Honan-Balloon IOP Reducer

Page 11: Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

Blanket Warmers

Our range of Blanket & Fluid Warming cabinets are designed to maintain blankets and fluids at a safe temperature to assist patient comfort in maternity, theatre, aged care etc. The fan forced system allows even temperature throughout the cabinet. The LED digital display allows you to see the temperature easily. Fitted with a built in HI alarm in case of overheating. Designed and built in Australia finished with stainless interiors/exterior and chrome plated shelves

Standard Features on all models – Double glazed doors

– Magnetic door closure

– Free standing / Bench / Wall mounted options available

– Radial hot air fan

– Micro-processor control

– LED Temperature control

– Temperature lock out

– Adjustable chrome plated shelving

– Stainless steel construction

Prices quoted do not include GST.Freight in addition where applicable.

Code Description

BW5 Single Door Blanket Warmer 500 x 575 x 600

BW10 Double Door Blanket Warmer 850 x 575 x 900

BW21 Single Door Blanket Warmer 750 x 700 x 1800

BM5 BM10 BM21

Blanket Warmers BW5 BW10 BW21

Set Point Temperature 60°C 60 °C 60 °C

Doors Single Door Double Door Single Door

Exterior Dimensions (W x D x Hmm) 500 x 575 x 600 (plus 25mm levelling feet)

850 x 575 x 900 (plus 25mm levelling feet)

750 x 700 x 1800 (plus 65mm castors)

Capacity 80L 257L 635L

Electrical Rating 240V 240V 240V

Connection Supplied 10 amp Power Cord 10 amp Power Cord 10 amp Power Cord

Element Watts 480W 720W 1320W

Over Temperature Protection +2°C +2°C +2°C

Shelves 2 3 5

Amps 2 amps 3 amps 5.5 amps

Page 12: Surgical Product Focus - Designs For Visiondfv.com.au/resources/DFV-Product-Focus-Edition-2-Final-v2.2.pdf · Designs For Vision also have its own surgical and diagnostic product

SYDNEY16/1 Hordern PlaceCamperdown NSW 2050

70B Lower Gibbes St,Chatswood NSW 2067

BRISBANE2/22 Hugo Place Mansfield QLD 4122

MELBOURNE26 Warterloo RoadCollingwood VIC 3066

ADELAIDE49 Bacon Street,Hindmarsh SA 5007

PERTH16 Howe StreetOsbourne Park WA 6017

NEW ZEALANDIRD 119 600 332Diagnostic: PO Box 38365Howick, Auckland 2145Surgical: PO Box 24-398Royal Oak, Auckland 1345Freecall: 0800 338 800

A ParagonCare Brand

T _ 1800 225 307F _ 02 9550 [email protected]

dfv.com.au