12
Siemens Aktiengesellschaft All rights reserved. © Siemens AG • 05/2016 Surge arrester 3EB4 Operating instructions Bestell-Nr.: 928 00180 176b Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved.

Surge arrester 3EB4 - cache.industry.siemens.com

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Surge arrester 3EB4 - cache.industry.siemens.com

Siemens Aktiengesellschaft All rights reserved. © Siemens AG • 05/2016

Surge arrester 3EB4

Operating instructions Bestell-Nr.: 928 00180 176b

Tran

smitta

l, rep

rodu

ction

, diss

emina

tion

and/o

r edit

ing o

f this

doc

umen

t as

well a

s uti

lizati

on o

f its

con

tents

and

comm

unica

tion

there

of to

other

s wi

thout

expr

ess

autho

rizati

on a

re p

rohib

ited.

Offen

ders

will

be h

eld li

able

for p

ayme

nt of

dama

ges.

All r

ights

create

d by

pate

nt gr

ant o

r re

gistra

tion o

f a ut

ility m

odel

or de

sign p

atent

are r

eser

ved.

Page 2: Surge arrester 3EB4 - cache.industry.siemens.com

2 © Siemens AG • 05/2016

Content Content __________________________________________________________________________ 2

Description _______________________________________________________________________ 4

Technical data 4

Design ___________________________________________________________________________ 5

Mode of operation 5

Transport and storage _____________________________________________________________ 7

Screwed joints 7

Installation _______________________________________________________________________ 8

Place of installation 8 Installing of the arrester 8 Earthing 9 Terminal 10

Disposal of arrester and arrester accessories _________________________________________11

Maintenance _____________________________________________________________________12

The manufacturer of this surge arrester

Siemens AG Energy Management · High Voltage Products

Surge Arresters

has introduced and applies a quality system in accordance with

DIN ISO 9001 / EN 29 001

Quality systems: Model for quality assurance. This system was first demonstrated in 1989 to the DQS (German Association for the Certification of Quality Systems).

The electrical testing laboratories and the materials technology laboratories of the manufacturer have been certified since 1992 by the German Accreditation Body in accordance with DIN EN ISO/IEC 17025.

If you require further copies of the operating instructions, please order them from the appropriate Siemens office,

indicating the title and order number shown on the title page.

Published by: In case of request: Siemens AG Telephone switchboard +49 / 30 / 386 1 EM HP AIS Sales department: +49 / 30 / 386 33222 D-13623 Berlin Fax: +49 / 30 / 386 26721 e-mail: mailto:[email protected] Subject to change.

Page 3: Surge arrester 3EB4 - cache.industry.siemens.com

© Siemens AG • 05/2016 3

Note The equipment covered by these instructions should be installed and serviced only by competent personnel familiar with good safety practices. This instruction is written for such personnel and is not intended as a substitute for adequate training and experience in safe procedures.

This information is intended for the correct installation of this product. Siemens has no control over the condition of the network, which can be greatly affected by the installation of a product. It is the responsibility of the user to chose the appropriate method of installation. Under no circumstance is Siemens liable for any direct or indirect damage caused by the use or misuse of this product.

Page 4: Surge arrester 3EB4 - cache.industry.siemens.com

4 © Siemens AG • 05/2016

Description The 3EB4 surge arrester serves to protect the insulation of a system (or of one of its components) from undue stresses resulting from overvoltages. It is designed for special operating conditions encountered aboard traction units.

Technical data The standard model is suitable for the operation of up to 1800 m above sea-level and for a rated frequency between 16 2/3 Hz and 62 Hz AC (3EB4 xxx-xAx3x-xx) and DC (3EB4 xxx-xDx3x-xx) respectively. The surge arrester meets the following standards as for as applicable:

Standard Classification VDE 0675-4 10 kA & 20kA

IEC 60099-4 Station Medium Duty (10 kA) Station Heavy Duty (20 kA)

EN 50526-1 DC-B EN 45545-2 IEC 61373-5

3EB4 xxx-xxS3x-xx 3EB4 xxx-xxM3x-xx 3EB4 xxx-xxL3x-xx 3EB4 xxx-xxX3x-xx

Fig. 1 Surge arrester type 3EB The rating plate [Fig. 2] is attached to the bottom flange.

AC surge arrester 3EB4 xxx-xAxxx-xx DC surge arrester 3EB4 xxx-xDxxx-xx 1 Order code 2 Rated voltage 3 Continuos operating voltage 4 Nominal discharge current 5 Rated short-circuit current

7 Year of manufacture 9 Serial No. 23 Frequency (only 3EB4 xxx-xAxxx-xx) 39 Repetitive charge transfer rating 55 Arrester Classification

Fig. 2 Rating plate

Date 2016/(9) IEC 60099-4

Ur (2) kV Uc (3) kV f (23) HzIn (4) kA Qrs (39) C Is (5) kA

Made in Germany Arrester class (55)

Gapless MO-Surge ArresterType: (1)

s

Gapless MO-Surge ArresterType: (1) -

s

Date 2016/(9) EN 50526-1

Ur (2) kV DC Uc (3) kV DC In (4) kA

Is (5) kA Qrs (39)C Arrester Class (55)

Made in Germany

Page 5: Surge arrester 3EB4 - cache.industry.siemens.com

© Siemens AG • 05/2016 5

Design The active components of the arrester are metal-oxide resistors. They are installed in an airtight sealed polymeric composite housing 1 (tube of fibre-rein-forced plastic with silicone rubber coatings [Fig. 3]. The housing consists of 2 major components: – A fibre-reinforced plastic tube to ensure high mechanical strength. If the arrester is overloaded the

tube does not break. This ensures that no parts are thrown off if the arrester fails. – The hydrophobic properties of the high-temperature cross-linked silicon rubber coating ensure that

electrical discharges on the housing surface are kept to a minimum; particularly good operating characteristics are therefore assured even under conditions of pollution.

The flanges (provided in some cases with integral gas diverter) are made of a weather-resistant light alloy and are bonded to the polymeric composite housing. UV and ozone resistant sealing rings and corrosion-resistant metal diaphragms ensure perfect sealing for years. The arrester is fitted with a pressure relief diaphragm and a gas diverter at the lower end [Fig. 3]. In the case of an arrester being overloaded, this pressure relief diaphragm will open at a pressure amounting to a fraction of the polymeric composite housing pressure resistance. Under these circumstances the gas flow is directed onto the arcing horn attached to the upper arrester flange, and so arcing can continue outside the housing until the feeder is switched off. Due to the high permissible bending moment and the excellent mechanical strength of the housing, the arrester type 3EB4 can be simultaneously used as a post insulator in addition to its actual arrester function. The function as a post insulator is not affected by an overload of the arrester. Before it is used as a post insulator, the manufacturer must be consulted to clarify the occurring loads.

Mode of operation

Metal-oxide resistors are highly non-linear, i.e. they have a sharply kinked voltage-current characteristic, with the result that below a certain voltage value only a small leakage current flows through the arrester. The arresters are so designed that under normal continuous voltage conditions only leakage current of approx. < 1mA flows. With lightning or switching overvoltages, the resistors become conductive (ohm range) so that a surge current can flow to earth and the overvoltage is reduced to the value of the voltage drop across the arrester (residual voltage). The surge currents have values of up to 500 A with switching overvoltages, and of 1 ... 5 ... 10 kA with lightning overvoltages.

Page 6: Surge arrester 3EB4 - cache.industry.siemens.com

6 © Siemens AG • 05/2016

1 Polymeric composite housing 2 Non-linear metal-oxide resistor 3 Flange with gas diverter 4 Intermediate plate 5 Drain hole Fig. 3 Sectional view

1

2

3

4 5

Page 7: Surge arrester 3EB4 - cache.industry.siemens.com

© Siemens AG • 05/2016 7

Transport and storage The arresters are packed according to the stresses and climatic conditions during transportation and to the customer’s specifications. The packing is provided with signs for transport and storage as well as directives for appropriate handling. As soon as the shipment arrives examine it for signs of damage. If such damage be found immediately notify the forwarding agent. Any parts packed separately should be checked against the dispatch notes. All the boxes should be opened for this purpose. With long storage it is recommended to leave the units and the accessories in the transport packing. As protection against mechanical, chemical and thermal influences (e.g. direct solar radiation, etc.) the surge arresters must be stored in a normally cool, dry and “dust-free” environment. Storage temperatures: -50°C to +60°C Relative air humidity below 80% at 15°C as annual mean value, 100% at 25°C as maximum value. Surge arresters which are removed from the vehicle must be thoroughly cleaned before storage.

Screwed joints Grease the bolt threads with Molykote Longterm 2 plus.

Attention Unchecked tightening can result in damage to or loosing of bolt joints. Use torque wrench for assembly.

Necessary torque for screwed joints:

M 6: 12 ± 2 Nm M 12: 45 ± 6 Nm

Page 8: Surge arrester 3EB4 - cache.industry.siemens.com

8 © Siemens AG • 05/2016

Installation Important note: Note the following before installing

Warning Before any work starts: switch off and isolate secure against reclosing verify that equipment is dead earth and short circuit the equipment cover or fence off nearby live parts

Death, severe injury and considerable damage to property and environmental damage may result if the safety instructions are not followed.

Confirm that these safety measures have been carried out. Accessories With the standard model, the following accessories are included in the scope of supply: – Connecting lug for earth connection

Place of installation The protective range of the surge arresters is limited. The place of installation must therefore be as close as possible to the equipment to be protected. The distance to earthed or live parts must be in accordance with relevant standards.

Attention The gas diverter should not point in the direction of another system component, so that the hot gases do not cause any damage during blow-out. Do not mount the arrester without intermediate plate [5 / Fig. 3].

Installing of the arrester The contact faces of the flanges of the arresters must be bright. The arresters can be mounted with 3 head screws or stud bolts M10 [Fig. 4 / Fig. 7].

Fig. 4 Standard – Mounting

Page 9: Surge arrester 3EB4 - cache.industry.siemens.com

© Siemens AG • 05/2016 9

Fig. 5 D260 Mounting

In other respects, the arrester must be installed at site in accordance with local conditions.

Fig. 6 Special mountings

* for horizontal application arrester has to be covered to avoid pollution of the sheds (upside-down)

Special mounting positions

Housingsize

Suspended application Horizontal application Allowable

vertical load

Allowable cantilever forces at

high voltage terminal

Allowable vertical catilever

forces at Top flange Fzus SLL SSL SLL SSL [N] [N] [N] [N] [N]

3EB4 xxx-xxS3x-xx 400 4890 12230 6690 16730 3EB4 xxx-xxM3x-xx 400 3840 9620 5300 13270 3EB4 xxx-xxL3x-xx 400 2660 6670 3740 9360 3EB4 xxx-xxX3x-xx 400 1780 4460 2570 6440

Earthing To ensure safe, reliable function of the arrester and optimal protection, earthing must be effective (low earthing resistance, short earthing connection). For earthing purposes the bottom flange of the surge arrester is equipped with one earth terminal for M12 bolt (the bolt is not scope of supply). So as not to reduce the protection level of the arresters the earthing connections should be as short and straight as possible. (Take account of the minimum cross-section of the conductor).

Page 10: Surge arrester 3EB4 - cache.industry.siemens.com

10 © Siemens AG • 05/2016

Fig. 7 Connecting lug for earth connection

Terminal For the connection between phase and surge arrester there are the following possibilities: – Flat connection, aluminium [Fig. 8] (Standard) The flat connection is equipped with a hole for M12

bolt (the bolt is not scope of supply)

Fig. 8 Terminal 3EB4 xxx-xxx32-xx

Pay attention to the electrochemical compatibility of the materials utilised. The flat connection is equipped with a hole for M12 bolt (the bolt is not scope of supply).

Fig. 9 Mounting terminal

The both M6 bolts may not be untighten or removed!

Page 11: Surge arrester 3EB4 - cache.industry.siemens.com

© Siemens AG • 05/2016 11

Disposal of arrester and arrester accessories Surge arresters and the accessories are an environmentally compatible product. In disposal, priority must be given to reuse of the materials. Environmentally acceptable disposal of the surge arresters and the accessories is possible in line with current legislation. The following materials have been used to make up the device: Steel, copper, aluminium, PTFE, cast resin or cast-resin-impregnated fabric, glass-fibre-reinforced plastics, polyurethane, rubbers for sealing, ceramics, electronic components and silicone rubber (VMQ), ceramics (porcelain, metal oxide). The device can be recycled as mixed scrap, or, if it is dismantled as far as possible, in a more environmentally acceptable way as sorted scrap with a mixed-scrap residual portion. The arrester resistors of metal oxide (MO) should be disposed of as industrial waste similar to domestic garbage (not as building rubble). In as-supplied-by-Siemens state, the device incorporates no hazardous substances in the sense of the pertinent regulations in Germany. If the device is to be operated outside Germany, the locally applicable laws and regulations must be followed. Local customer support offices will be able to answer any questions concerning disposal.

Page 12: Surge arrester 3EB4 - cache.industry.siemens.com

12 © Siemens AG • 05/2016

Maintenance

Warning

Before any work starts: switch off and isolate secure against reclosing verify that equipment is dead earth and short circuit the equipment cover or fence off nearby live parts

Death, severe injury and considerable damage to property and environmental damage may result if the safety instructions are not followed.

Confirm that these safety measures have been carried out. Regular maintenance of the surge arrester is not required. Inspections are limited to the checking the arrester for signs of overloading (black or burned spots at the blow-out hole in the flange). In this case the arrester must be replaced. Cleaning of the silicon sheds is recommended annually or after 1.000.000 km travelled. The arrester is resistant to the usual cleansing agents and methods used in the rail area. If it is cleaned by hand, only use clear water or soap water, and only soft cloths or sponges. Use other cleaning liquids only after consulting the manufacturer.

Attention 1. Do not use abrasive or grinding substances. 2. Do not use solvents. 3. Do not use strong acid and lye. 4. It is recommended to use detergent-based clean agent like

soap. 5. After cleaning with acid, lye or detergent-based clean agent the

insulator must be washed with bright water to prevent swelling effect on silicon, which might cause irreversible damages on the products.