12
General description Yarway Pipeline Wye Strainers are in thousands of applications in chemical, petroleum, pulp and paper, and utilities, as well as numerous commercial and institutional locations. These strainers have been designed following time tested principles to conform to applicable codes and standards such as Power Piping ANSI B31.1. They have successfully passed stringent shock and vibration tests. Body materials and end connections conform to recognized standards. Screens are stainless steel or Monel ® . Spark-plug-like, clad, non-asbestos gaskets are used to provide reliable sealing with minimal loading. Screens are guided, not crushed, into bodies, caps and covers for confident particle retention. Applications The Yarway Pipeline Wye Strainers are suitable for use in a variety of fluid systems such as air, chemical, condensate, gas, oil, petroleum or water lines, for the protection of valves, pumps, compressors, condensers, flow meters, nozzles, steam traps and other vulnerable equipment. Monel ® is a registered trademark of International Nickel Company. Yarway Wye-Type Pipeline Strainers Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-0431-US-0410 Total Flow Control Solutions™ Flow Control I S O 9 0 0 1 L L O Y D ' S R E G I S T E R Q U A L I T Y A S S U R A N C E Suitable for use in a variety of fluid systems. Yarway and Unibody ® are registered trademarks of Tyco International Services AG or its affiliates in the United States and/or other countries. All other brand names, product names, or trademarks belong to their respective holders.

Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

General descriptionYarway Pipeline Wye Strainers are inthousands of applications in chemical,petroleum, pulp and paper, and utilities,as well as numerous commercial andinstitutional locations.

These strainers have been designedfollowing time tested principles toconform to applicable codes andstandards such as Power Piping ANSIB31.1. They have successfully passedstringent shock and vibration tests.

Body materials and end connectionsconform to recognized standards.Screens are stainless steel or Monel®.Spark-plug-like, clad, non-asbestosgaskets are used to provide reliablesealing with minimal loading. Screensare guided, not crushed, into bodies,caps and covers for confident particleretention.

ApplicationsThe Yarway Pipeline Wye Strainers are suitable for use in a variety of fluid systems such as air, chemical,condensate, gas, oil, petroleum or waterlines, for the protection of valves,pumps, compressors, condensers, flowmeters, nozzles, steam traps and othervulnerable equipment.

Monel® is a registered trademark of InternationalNickel Company.

Yarway Wye-Type Pipeline Strainers

Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-0431-US-0410Total Flow Control Solutions™

Flow ControlI S O 9 0 0 1

LLO

YD

'SR

EGIS

TER QUALITYA

SSUR

AN

CE

Suitable for use in a variety of fluid systems.

Yarway and Unibody® are registered trademarks ofTyco International Services AG or its affiliates in theUnited States and/or other countries. All other brandnames, product names, or trademarks belong to theirrespective holders.

Page 2: Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

Yarway Wye-Type Pipeline Strainers

Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-04312

Features and benefits• Body material - ASTM and/or ASME

as permitted under Boiler Code and Power Piping Code. Providesassurance of quality and suitability for pressure/temperature adjustment innon-shock service.

• Straight threads on cap - for easyremoval when screen replacement is necessary.

• Clad, non asbestos, spark-plug-typegasket provides reliable seal onmachined body and cap.

• Guided screen - screens fit intocontrolled machined bores in body and cap, and are not crushed. This fit provides good screen alignment and reliable capture of particles.

• Installation - can be installed in verticaland horizontal piping with the blowdownconnection oriented in any preferreddirection.

• Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms torecognized codes and standards forassurance of quality.

How to SelectThere are three important componentsin selection:

1.Design and operating pressures andtemperatures - look at the curves inFigure 2. Select the strainer rating that meets both the design and theoperating requirements.

2.Flow rate and pressure drop - select a strainer pipe size that will yield apressure drop of 11/2 psi or less.This will accommodate increases inpressure drop due to dirt or alternatescreens without causing the screen to rupture.

3.Look at the Selection Table on page 4and pick the strainer series that meetsthe conditions of 1 and 2 above, and iscompatible with the flowing medium.

InstallationStrainers should be installed upstreamof pipeline equipment to protect againstdamage from solid particles of dirt,chips, scale, packing shreds, pipesealants and welding debris.

The strainer should be fitted with a pipenipple in the cap or cover and a fullported straight through valve (e.g., gateor ball).

Install the strainer in a horizontal orvertical line with flow in the direction of the arrow.

For freeze protection, install the straineron its side or upside down in a horizontalline or vertically to assist in draining theblowdown line and strainer cavity.

Inspect the strainer regularly. Clean thescreen before it becomes more thanone-third clogged. Pressure gagesbefore and after the strainer will indicateexcessive pressure losses due toclogging.

Page 3: Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

Yarway Wye-Type Pipeline Strainers

Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-04313

Straight throughdesign. Minimumpressure drop.Full draining.

Generously sized,corrosion resistantscreen for mostapplications.

ANSI Class Rating for non-shockpressure/temperatureadjustment.

Straight machinethreads in bodyand on cap forease of removal.

Machined body and cap,metal clad non-asbestosgaskets for reliable seal.

Proper screen retentionand alignment forreliable capture ofparticles.

ANSI Class flanges.

Machined surfaces,non-asbestos gasketand bolted cover forreliable seal.

Blow-offconnection.

Generously sized,corrosion resistantscreen for mostapplications.

900 Series, threaded cap

800 and M800 Series, bolted cover

Page 4: Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

Yarway Wye-Type Pipeline Strainers

Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-04314

Threaded socketwelding and flanged strainersMaterials

Strainer End Connection Body Threaded Cap Gasket Screen Type AvailableFigure and Nominal 900 Series and Material2 Pipe Sizes

Number ANSI Class Bolted Cover in. [DN]Ratings1 M800 and 863

901 Threaded B16.4 Cast Iron Steel Copper Clad 1/32” Perf. 3/8” - 2”CL 250 A-278 CL 35 Non-Asbestos 18-8 SS [10 - 50]Threaded B16.4 Cast Iron Cast Iron 1/32” Perf. 21/2” - 3”

M801 CL 250 A-126 CL B A-126 CL B Non-Asbestos 18-8 SS [65-80]

M804 Flanged F.F. B16.1 Cast Iron Cast Iron Non-Asbestos1/32” Perf. to 4” 18-8 SS 11/2” - 8”

CL 125 A-126 CL B A-126 CL B 3/64” Perf. 5” - 8” 18-8 SS [40 - 200]Flanged 1/16” RF Cast Iron Cast Iron 1/32” Perf. to 4” 18-8 SS 11/2” - 8”

M806 B16.1 CL 250 A-126 CL B A-126 CL B Non-Asbestos 3/64” Perf. 5” - 8” 18-8 SS [40 - 200]

921 Threaded B1.20.1 Cast Steel Steel SS Clad 1/32” Perf. 1/2” - 2”CL 600 A-216 WCB Non-Asbestos 18-8 SS [6 - 50]Threaded B1.20.1 Cast Steel Spiral Wound 1/32” Perf. 21/2” - 3”

M821 CL 600 A-216 WCB Cast Steel Non-Asbestos, SS 18-8 SS [65 - 80]

921SW Socketwelding Cast Steel Steel SS Clad 1/32” Perf. 3/8” - 2”B16.11 CL 600 A-216 WCB Non-Asbestos 18-8 SS [10 - 50]Socketwelding Cast Steel Copper Clad 1/32” Perf. 21/2” - 3”

M831 B16.11 CL 600 A-216 WCB Cast Steel Non-Asbestos 18-8 SS [65 - 80]

M828 Flanged 1/16” RF Cast Steel Cast Steel Non-Asbestos1/32” Perf. to 4” 18-8 SS 1/2” - 11/2”

B16.5 CL 150 A-216 WCB 3/64” Perf. 5” - 8” 18-8 SS [15 - 40]Flanged 1/16” RF Cast Steel 1/32” Perf. to 4” 18-8 SS 2” - 8”

M838 B16.5 CL 150 A-216 WCB Cast Steel Non-Asbestos 3/64” Perf. 5” - 8” 18-8 SS [50 - 200]

M822 Flanged 1/16” RF Cast Steel Cast Steel Non-Asbestos1/32” Perf. to 4” 18-8 SS 1/2” - 11/2”

B16.5 CL 300 A-216 WCB 3/64” Perf. 5” - 8” 18-8 SS [15 - 40]Flanged 1/16” RF Cast Steel 1/32” Perf. to 4” 18-8 SS 2” - 8”

M832 B16.5 CL 300 A-216 WCB Cast Steel Non-Asbestos 3/64” Perf 5” - 8” 18-8 SS [50 - 200]

M824 Flanged 1/4” RF Cast Steel Cast Steel Spiral Wound 1/32” Perf. to 4” 18-8 SSB16.5 CL 600 A-216 WCB Non-Asbestos, SS 3/64” Perf. 5” - 8” 18-8 SS

Notes

1. See Chart, Figure 2 (page 10) for pressure-temperature ratings.

2. See page 11 for optional screen materials andopenings.

Page 5: Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

Yarway Wye-Type Pipeline Strainers

Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-04315

1098765

4

3

2

1.0.9.8.7.6.5

.4

.3

.2

.1

.5

.4

.3

.2

.1

.05

.04

.03

.02

.01

.5 1 2 5 10 20 50 10 200 500

1 2 3 4 5 6 7 8 9 10 2 3 4 5 6 7 8 9100 2 3 4 5 6 7 8 9 1000 2 3

Clogged screens - This chartrepresents the results of tests conductedwith strainers containing clean screens.With screens 50% clogged, pressuredrop results are approximately doublethose shown in charts.

Multiplying factor - All results arebased upon the use of 0.033 dia.through 1/4” dia. perforations. Whenusing .020 perforations, multiplypressure drop from graph by 1.10. Formesh lined perforated metal screens,multiply pressure drop by 1.25.

Flow rate, gpm water

Figure 1

Cv

Pre

ssur

e dr

op, p

si

Pre

ssur

e dr

op, b

ar

3 /8”,

1 /2” -

900

3 /4” -

900

1”- 9

00

11 /4

” - 9

001

1 /2” -

900

2”- 9

00

1 /2” -

M80

0

3 /4” -

M80

0

1”- M

800

11 /4

” - M

800

11 /2

” - M

800

2”- M

800

21 /2

” - M

800

3”- M

800

4”- M

800

8”- M

800

5”- M

800

6”- M

800

Cv = GPM

∆PS.G. S.G. = Specific gravity

How to specify threaded capBody shall be Wye-type. Threaded capshall have straight machined threads foreasy removal. Body and cap shall havemachined surfaces for metallic clad,non-asbestos gaskets. Strainer screenshall fit into non-tapered machinedbores. Thread end strainers shall bemachined to ANSI B1.20.1. Socketweldingends shall be to ANSI B16.11; flangedends shall conform to ANSI B16.4 (iron)or B16.5 (steel).

Bolted coverBody shall be Wye-type. Covers shall bebolted for easy removal. Body and covershall have machined surfaces for non-asbestos gasketing. Screen shall fit intonon-tapered, machined bores. Strainerends shall conform to ANSI B1.20.1 forthreads, ANSI B16.11 for socketweldingand ANSI B16.4 (iron) or B16.5 (steel)for flanged.

How to orderSpecify pipe size, Yarway series andpipe connection. Example: 3/4”, YarwaySeries 921, NPT ends.

Water flow vs. pressure drop

Flow rate, m3/hr.

Page 6: Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

Yarway Wye-Type Pipeline Strainers

Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-04316

Pressure drop through YarwayWye strainersIn the application of Wye strainers themost frequent concern is pressure drop.Since the strainers can have a variety offluids passing through them, there are avariety of equations and conditions thataffect the flow.

Our objective is to present methods for calculating pressure drops acrossYarway’s Wye Type strainers. Thecalculations are based on a series offormulas and the use of a Cv, and coversliquids, steam and gases.

The following assumptions are made:

1. Control valve equations and the use ofCv is appropriate.

2. For liquid flow:

• Flashing and cavitation are notpresent.

• There is no significant change indensity.

• Flow is fully turbulent and viscosity is not a significant factor in thecalculations for pressure drop.

3. For steam, gas and air flows, pressuredrops are not critical, and a change indensity (if it occurs) is not significant.

The examples of pressure dropcalculations are based on new, cleanstrainers. If clogged screens are asignificant concern, follow the footnoteunder Figure 1.

Determine the strainer CvThe first thing to determine is thestrainer Cv. This can be obtained fromFigure 1 the water flow vs pressure dropcurve where Cv = gpm when thepressure drop is one (1) psi.

Example:

What is the Cv for a 3” M800 YarwayWye strainer?

Solution:

1. Enter the left, vertical axis at one(1.0) psi.

2. Move horizontally to the right untilyou reach the 3” M800 curve.

3. Then, move vertically down andread 150 gpm.

4. Answer - The Cv for a 3” M800 is150.

This solution is for water; specific gravityis approximately one.

Liquid flow with specific gravitynot equal to oneExample:

What is the pressure drop if the fluid iskerosene, flowing at 150 gpm for a 3”M800 strainer?

Solution:

1. Enter a table of various liquids.

2. Find kerosene with a specific gravityof 0.82.

3. Solve the equation

Equation 1:

∆ PI = G ( V I )2

Cv

= (0.82) ( 150 )2= 0.82 psi

150Where:

∆ PI = Liquid/pressure drop, psi

VI = Liquid flow, gpm = 150(previous example)

Cv = Strainer Cv = 150 (previousexample)

GI = Specific gravity of liquid. Forkerosene GI = 0.82

Liquid flow, viscosityconsiderationWith the turbulent flow, the pressuredrop equations are independent ofReynolds Number. When viscous fluidsare present, Reynolds Numbers can bechanged to the point where Laminar flowis achieved. The use of Equation 2 and 3determines if the flow is turbulent. If it is turbulent, Equation 4 can be used.If Reynolds Number is less than 4000,Equation 4 will predict a greater thanexpected pressure drop.

Equation 2:

Re = 3160 VIvd

Re = Reynolds No.

VI = GPM

v = Kinematic viscosity, centistokes

Equation 3:

VI =Cv ∆Pv

GI

GI = Specific gravity of liquid

∆Pv = Viscous fluid, pressure drop, psi

d = Pipe I.D. inch

Combining Equation 2 and 3 andassuming Re = 4000 minimum forturbulent flow, and “d” is a controllingfactor for the strainer:

4000 = (3160)( Cv ) ∆Pv

vd GI

or

Equation 4:

∆Pv = (1.6023)(GI) (vd)2

Cv

Example:

Assume the same 3” strainer flowingkerosene. The specific gravity is 0.82,but the kinematic viscosity is 2.69. PipeI.D. is 3.068 inches. Using Equation 4:

∆Pv = (1.6023)(0.82) (2.69 x 3.068)2

150

= .004 psi minimum for aReynolds Number of 4000 to maintain turbulent flow.

This means that if the pressure drop andReynolds Number are too low, Laminarflow may result and the influence ofviscosity can alter the results. Theapproximate Reynolds Number for 150 gpm flow in the example is:

Re =(3160) (150)

(2.69) (3.068)

is over 57, 400 from equation(2) and the ∆Pv approaches0.82 from equation (3).

Page 7: Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

Yarway Wye-Type Pipeline Strainers

Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-04317

Gas and vapor flowThe flow of gases and vapors is more complicated than liquid flow.This is due to changes in density. If pressure drops are too great,the nature of the gas or vapor changes.

These equations are assumed to apply:

In the above, it is assumed that the control valve formulas for non-critical steam and gas flow are applicable.

∆Ps = Pressure drop across strainer, steam psi

∆Pg = Pressure drop across strainer, gas, air, etc.

P1 = Strainer inlet pressure, psia

W = lb/hr steam flow

Q = SCFH gas flow

Ts = Degrees F superheat above saturation

T = Degrees R gas temperature (F7460)

G = Specific gravity, gas (air = 1)

Saturated steam flowLet’s assume we have a 2” steam line. Steam flow is 2000 lb/hrand the steam pressure is 100 psig, saturated. What is thepressure drop through the 2” Yarway 921 Wye Strainer?

From Figure 1 we see that the 2” 921 has a Cv equal to 55.

P1 = 100 psig = 115 psia

W = 2000 lb/h

Cv = 55

Ts = 0, because the steam is saturated

Superheated steamAssume the same strainer and conditions as for saturated steam,except the steam temperature is 500°F.

We use the same equation except

Ts = 500-338

Ts = 162°F, degrees superheat

500 = Steam temp, F

338 = Sat. temp, F for 100 psi

GasesIf we keep the same strainer, but now consider natural gas flow at50,000 SCFH and at a temperature of 100°F.

Cv = 55

P1 = 115 psia

G = 0.667

T = 460 + 100 = 560R

Q = 50,000

Steam (saturated or superheat)

Equation 5:

∆Ps = P1 - (P1)2 - (W) (1 + 0.0007 Ts) 2

(2.1) (Cv)

Gases (including air)

Equation 6:

∆Pg = P1 - (P1)2 - (G) (T) (Q) 2

(963) (Cv)

From Equation 5:

∆Ps = (115) - (115)2 - (2000) (1 + 0) 2

(2.1) (55)

= 1.31 psi drop

The steam pressure drop is calculated to be 1 to 11/2 psi.

∆Ps = (115) - (115)2 - (2000) (1 + 0.0007 x 162) 2

(2.1) (55)

∆Ps = 1.63 psi

The superheated steam will produce a pressure dropnearly 1/4 more than the saturated condition.

∆Pg = (115) - (115)2 - (0.667) (560)50,000 2

(963) (55)

= 1.46 psi

Pressure drop is approximately 11/2 psi.

Page 8: Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

Yarway Wye-Type Pipeline Strainers

Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-04318

Easily Removable Screen CapsStraight threads permit easy removal from the strainer body when the screen must becleaned, and assure proper alignment of the screen when re-assembled. Machinedfaces and “spark plug” type gasket provide a good joint without excessive tightening. On21/2” and 3” strainers, four bolt covers are used instead of threaded screen caps.

Dimensions, in. [mm]Strainer 901, M801 921, 921 SW

Size M821, M831in. [DN] A B A B

3/82 31/8 25/32 35/16 25/32[10] [80] [55] [84] [55]1/2 31/8 25/32 35/16 25/32

[15] [80] [55] [84] [55]3/4 35/8 215/32 313/16 215/32[20] [92] [63] [97] [63]1 43/8 31/32 49/16 31/32

[25] [111] [77] [116] [77]11/2 6 49/32 61/8 49/32[40] [152] [109] [156] [109]2 71/8 57/32 71/2 57/32

[50] [181] [133] [191] [133]21/21 121 71/21 113/41 71/21

[65] [305] [191] [298] [191]31 121 71/21 113/41 71/21

[80] [305] [191] [298] [191]

Notes1. Series M800 strainers. Threaded inlet, outlet and blow-off connections are NPT standard;

socketwelding connections are machined to ANSI standard.

2. Not available in 931, 931SW and 863.

Weight, lb. [kg]Strainer Size Strainer Weights

in. [DN] 901 921, 921SWM801 M821, M831

3/8 1 11/2[10] [0.5] [0.7]1/2 11/4 11/2[15] [0.6] [0.7]3/4 11/2 2[20] [0.7] [0.9]1 3 31/2

[25] [1.4] [1.6]11/2 61/2 71/4[40] [2.9] [3.3]2 111/4 13

[50] [5.1] [5.9]21/21 471 451

[65] [21.3] [20.4]31 471 451

[80] [21.3] [20.4]

Note1. Series M800 strainers. Threaded inlet, outlet

and blow-off connections are NPT standard;socketwelding connections are machined toANSI standard.

Standard Blow-off Connections,Dimension C1

Series 900, M801, M821 and M831Strainer size, Connection NPT,

in. [DN] in. [DN]1/2 3/8[15] [10]3/4 1/2[20] [15]

11/2 - 2 3/4[40 - 50] [20]21/2 - 3 M801 M821, M831[65 - 80] 1 [25] 11/4 [32]

Note1. Threaded blow-off connection standard.

Consult Yarway for optional sizes andsocketwelding.

Series 901, 921 and 921SW, threaded,socketwelding ends (with threadedscreen caps).

Threaded and SocketweldingStrainers

A

B45°

C

A

B45°

C

Series M801, M821, M831 threaded end.

Page 9: Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

Yarway Wye-Type Pipeline Strainers

Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-04319

Yarway M Series flanged end strainers are furnished with bolted covers. Standardmaterials are cast iron and carbon steel, in sizes 1/2” to 8”. Sizes to 16” are available as well as optional materials.

Dimensions, in. [mm]Strainer M804 M806 All M828 M822 M824 M838 M832 M824

Size Ratingsin. [DN]1 A A B A A A B B B

1/2 — — — 57/8 61/8 65/8 — — 31/4[15] — — — [149.2] [155.6] [168.3] — — [82.6]3/4 — — — 73/8 73/4 85/16 — — 37/8[20] — — — [187.3] [196.9] [211.1] — — [98.4]1 — — — 73/8 77/8 85/16 — — 37/8

[25] — — — [187.3] [200.0] [211.1] — — [98.4]11/2 71/2 81/16 41/2 71/8 75/8 101/4 — — 51/2[40] [190.5] [204.8] [107.9] [180.9] [193.7] [260.4] — — [139.7]2 91/8 95/16 53/4 — — 11 51/4 51/4 73/8

[50] [231.8] [236.5] [146.1] — — [279.4] [133] [133] [187.3]21/2 101/2 111/16 71/8 — — 12 61/2 61/2 85/8[65] [266.7] [280.9] [180.9] — — [304.8] [185] [185] [219.1]3 12 125/8 91/4 — — 131/2 7 7 93/4

[80] [304.8] [320.7] [234.9] — — [342.9] [178] [178] [247.7]4 149/16 155/8 107/8 — — 1715/16 81/4 81/4 133/8

[100] [369.9] [396.9] [276.2] — — [455.6] [210] [210] [339.7]5 167/8 155/8 133/8 — — 221/4 111/4 111/4 153/8

[125] [428.6] [396.9] [339.7] — — [565.2] [286] [286] [390.5]6 183/4 203/16 15 — — 255/8 131/2 131/2 20

[150] [476.25] [512.8] [381.0] — — [650.9] [343] [343] [508.0]8 215/8 251/8 163/4 — — 313/4 151/2 153/4 241/2

[200] [549.3] [638.2] [425.5] — — [806.45] [394] [400] [622.3]

Weight, lb. [kg]Strainer Strainer Weights

Size in. [DN]1 M804 M806 M838 M832 M8241/2 — — 5 51/2 6[15] — — [2.3] [2.5] [2.7]3/4 — — 9 113/4 12[20] — — [4.1] [5.3] [5.4]1 — — 10 123/4 13

[25] — — [4.5] [5.8] [5.9]11/2 17 24 17 22 27[40] [7.7] [10.9] [7.7] [10.0] [12.4]2 22 26 18 22 39

[50] [10.0] [11.8] [8.2] [10.0] [17.7]21/2 34 40 28 32 60[65] [15.4] [18.2] [12.7] [14.5] [27.2]3 46 59 34 49 75

[80] [20.9] [26.8] [15.4] [22.2] [34.1]4 79 93 58 90 160

[100] [35.8] [42.2] [26.3] [41] [72.5]5 119 146 90 120 260

[125] [54.0] [66.2] [41] [54.4] [118.0]6 161 194 125 175 360

[150] [73.1] [88.0] [56.7] [79] [163.0]8 269 316 220 300 635

[200] [122.0] [143.0] [100] [136] [288.0]

Notes1. Metric pipe equivalents.

2. 10”, 12”, 14” and 16” sizes available. Consult Yarway.

Standard Blow-off Connections,Dimension CStrainer size, Blow-off Connection

in. [DN] NPT2 in. [DN]1/2 M822 3/8[15] M828 [10]

3/4 - 11/2 M822 1/2[20 - 40] M828 [15]

2 1/2[50] [15]21/2 1[65] [25]

3 M806 11/4 M804 1[80] M824 [32] M832 [25]M8384 11/2

[100] [40]5, 6 and 8 2

[125, 150 and 200] [50]

Notes1. All strainers supplied with blow-off

connections. For connections other than listedabove, consult Yarway.

2. Consult Yarway for availability of socketweldingblow-off connections.

Series “M” flanged strainers in iron andcast carbon steel.

Flanged Strainers

A

B

C

Page 10: Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

0 100 200 300 400 5003800

3500

3000

2500

2000

1500

1000

500

0

260

250

200

150

100

50

00 100 200 300 400 500 600 700 800 900 1000

Prolonged exposure notrecommended above 800°Ffor carbon steel strainers

Saturation curve

921, 921SW600 psi CS

M832, M822300 lb., Fig. CS

M838, M828150 lb., Fig. CS

911, 300 psi Bronze

901, 250 psi CI

M824, 600 lb., Fig., CS

921,921SW

M824

Yarway Wye-Type Pipeline Strainers

Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-043110

Screen equivalent guidePerforations Approximate Equivalent

Diameter Number of Perf. Mesh Fraction, in.in. [mm] per square inch

0.020 [0.51] 625 42 1/64

0.0331 [0.84] 324 27 1/32

0.045 [1.14] 225 20 3/64

0.062 [1.57] 96 15 1/16

0.125 [3.18] 33 8 1/80.0052 [0.13] 20x120 Dutchweave 100 —

Notes1. Standard perforation on most 900 series strainers.

2. Approximate particle size retention.

Yarway Wye-Type Pipeline Strainers (MAP) Design – Pressure/Temperature Ratings

System design temperature, °F

Figure 2

Sys

tem

des

ign

pres

sure

, psi

g (n

on-s

hock

)

Sys

tem

des

ign

pres

sure

, bar

(no

n-sh

ock)

System design temperature, °C

Page 11: Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

Yarway Wye-Type Pipeline Strainers

Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-043111

Screens

Perforated screen - easy to clean, lesssusceptible to clogging.

Dutchweave screen for applicationsrequiring retention of small particles.

Two types of screens for a range of process conditionsPerforated stainless steel or Monel® in a wide range of opening sizes with high openarea ratios for low pressure drops. Fine mesh stainless steel Dutchweave screens alsoavailable. Both types provide greater mechanical strength than ordinary square mesh.Machined recesses in the body and cap assure the proper fit of the screen and itsalignment in the body.

Screen Selector Guide - Series 900 and 863Type of Service Screen Opening, in.

Air or gas Dutchweave (100 mesh)Oil, low viscosity 0.033” or 0.045” perf.Oil, medium or high viscosity 0.045” or 0.062” perf.Steam 0.020” or 0.033” perf.Water, gasoline or light fuel oil 0.020” or 0.033” perf.

Screen Selector Guide - Series M8001

Service Sizes, in. [DN] Coarse Medium FineStraining, in. Straining, in. Straining, in.

Air or gas1/2 - 4 [15 - 100] 1/32 perf. 60 mesh 100 mesh2

5 - up [125 - up] 3/64 perf. 1/32 perf. 60 mesh1/2 - 4 [15 - 100] 3/64 perf. 1/32 perf. 0.020 perf.

Gasoline5 - up [125 - up] 0.057 perf. 3/64 perf. 1/32 perf.

Oil - Low 1/2 - 4 [15 - 100] 3/64 perf. 1/32 perf. 0.020 perf.Viscosity 5 - up [125 - up] 0.057 perf. 3/64 perf. 1/32 perf.Oil - Medium 1/2 - 4 [15 - 100] 0.057 perf. 3/64 perf. 1/32 perf.Viscosity 5 - up [125 - up] 1/8 perf. .057 perf. 3/64 perf.Oil - High 1/2 - 4 [15 - 100] 1/8 perf. .057 perf. 3/64 perf.Viscosity 5 - up [125 - up] 1/4 perf. 1/8 perf. 0.057 perf.

1/2 - 4 [15 - 100] 3/64 perf. 1/32 perf. 0.020 perf.Steam

5 - up [125 - up] 0.057 perf. 3/64 perf. 1/32 perf.

Water1/2 - 4 [15 - 100] 3/64 perf. 1/32 perf. 0.020 perf.5 - up [125 - up] 0.057 perf. 3/64 perf. 1/32 perf.

Notes1. Series M800 screens are not interchangeable

with Series 900 and 863 strainers.

2. Mesh lined screens.

Page 12: Suitable for use in a variety of fluid systems. · • Design - meets ANSI B31.1 and Navy Spec MIL-S-2953. Conforms to recognized codes and standards for assurance of quality. How

Yarway Wye-Type Pipeline Strainers

Copyright © 2004 Tyco Flow Control. All rights reserved. YAWMC-043112

Tyco Flow Control (TFC) provides the information herein in good faith but makes no representation as to its comprehensiveness or accuracy. This data sheet is intended only as a guide to TFC products andservices. Individuals using this data sheet must exercise their independent judgment in evaluating product selection and determining product appropriateness for their particular purpose and system requirements.TFC MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULARPURPOSE WITH RESPECT TO THE INFORMATION SET FORTH HEREIN OR THE PRODUCT(S) TO WHICH THE INFORMATION REFERS. ACCORDINGLY, TFC WILL NOT BE RESPONSIBLE FORDAMAGES (OF ANY KIND OR NATURE, INCLUDING INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES) RESULTING FROM THE USE OF OR RELIANCE UPON THIS INFORMATION.Patents and Patents Pending in the U.S. and foreign countries. Tyco reserves the right to change product designs and specifications without notice.

www.tycovalves.com

Tyco Valves & Controls

Unibody® PlusIn-line renewable traps for tracingand steam line drips

The UniBody Plus line of steam trapsincludes five different types of in-linerenewable traps: “zero steam loss” disc,variable orifice (piston), orifice and thepatented cyclic, fail open thermostatic.Two types of trap bodies with eitherthreaded or socketwelding endconnections are available in the UniBodyPlus line: a trap body only or a completetrapping station with integral “Wye”strainer or blow-off valve. Once installed,the body stays in-line. Simply install alow torque renewal trap capsule.

Thermodynamic and thermostatictraps for process applications

Process heat exchange applicationsrequire traps that purge large volumes of air, provide fast warm-up and respondquickly to operating conditions. TheSeries 151, 40/40D and 731/741 withrenewable internals have proven theirability to meet these applicationrequirements.

In addition, these traps all feature smallcompact designs that are easy to installand maintain which results in reducedcosts. The traps are self-draining andunaffected by freezing.

Typical process equipment using thesetraps include evaporators, air heatingcoils, autoclaves, shell and tube heatexchangers, and submerged coils.

Other products

Series 751/761Filled thermal element traps

Series 40/40DLever valve

Series 151Dual range

Piston

Filledthermalelement Disc

HPdisc