Designed And Built To Perform With Efficient Reliability.RA7-14/2MPrinted in U.S.A.
676 Broadway Street • Dayton, Tennessee 37321 • (423) 775-2131 • Fax: (423) 775-7015
Vertical Packaged Air Conditioner Featuring Gas Heat/Electric Cooling
Ideal For Multi-Family Applications
Fully Self-Contained Heating and Cooling System That Provides Designers and Builders with a Cost Effective Alternative to Condition Multiple Rooms.
• 1 to 3 Tons Cooling
• 36 – 60 MBTU GAS Heat
• No Outside Condensing Unit
• S Series – Standard – 80% AFUE
• H Series – High Efficiency – 90%+ AFUE
• R-410A Refrigerant
• Insulated 16 GA Coated Steel Base Pan
MODEL Height Width Depth
S and H Models - Dimensions In Inches
DYPA18, 18H DYPA24, 24H DYPA30, 30H DYPA36, 36H
DYPA12, 12H 60-1/260-1/260-1/264-1/264-1/2
28-1/828-1/828-1/828-1/8
24-1/224-1/224-1/2
24-1/224-1/228-1/8
www.suburbanmanufacturing.com
Suburban Division
¹The official energy descriptor recognized by Department of Energy for this type of unit is EER. ²Unit Tested to ANSI/AHRI Standard 390.
Warranty: The DynaPack is backed by a one year limited warranty on parts and labor and
a five year limited warranty on the compressor and heat exchanger.
¹The official energy descriptor recognized by Department of Energy for this type of unit is EER. ²Unit Tested to ANSI/AHRI Standard 390.
COOLINGSOUND
PRESSURELEVELS
Btuh EER²Seer¹ Refrigerant Indoor(dBA)
Outdoor(dBA)
HEATING
64 69
64 69
64 69
64 74
R-410A
R-410A
R-410A
R-410A
R-410A 64 74
11
12
12.1
12.35
11.5
10.2
10.6
10.6
10.7
10
12,000
17,500
25,200
30,200
34,800
80%
80%
80%
80%
80%
InputBtuh
35,50047,50035,50047,50059,00035,50047,50059,00035,50047,50059,00035,50047,50059,000
OutputBtuh
28,40038,00028,40038,00047,20028,40038,00047,20028,40038,00047,20028,40038,00047,200
DYPA12AC1A036DYPA12AC1A048DYPA18AC1A036DYPA18AC1A048DYPA18AC1A060DYPA24AC1A036DYPA24AC1A048DYPA24AC1A060DYPA30AC1A036DYPA30AC1A048DYPA30AC1A060DYPA36AC1A036DYPA36AC1A048DYPA36AC1A060
S SERIESMODEL
AFUE
SUBURBAN DYNAPACK SPECIFICATIONS
COOLINGSOUND
PRESSURELEVELS
Btuh EER²Seer¹ Refrigerant Indoor(dBA)
Outdoor(dBA)
HEATING
12,000 11 10.2 R-410A
R-410A
R-410A
R-410A
R-410A
64 69
64
64
64
64
6912 10.617,500
AFUE
92%92%91%
InputBtuh
OutputBtuh
39,00039,00052,000
52,000
52,000
52,000
36,00036,000
47,300
47,300
47,300
47,300
DYPA12AC1A039HDYPA18AC1A039HDYPA18AC1A052H
6912.1 10.625,20092%91%
39,000 36,000DYPA24AC1A039H
DYPA24AC1A052H
7410.712.3530,20092%39,000 36,000DYPA30AC1A039H91%DYPA30AC1A052H
7411.5 1034,80092%39,000 36,000DYPA36AC1A039H91%DYPA36AC1A052H
H SERIESMODEL
Designed And Built To Perform
With Efficient Reliability
5.225
35 oz.
Rotary ReciprocatingR410A
8.343
43 oz.10.954
85 oz.13.174
96 oz.1688
96 oz.
Type Refrigerant type (HCFC) Unit refrigerant charge ounces Rated load amps Locked rotor amps
COMPRESSOR
4.0/.50/1050
0.90.9/0.125/1075 1.3/0.25/1075
Indoor motor (ECM) FLA/HP/RPM Condensor motor FLA/HP/RPM Combustion motor FLA
MOTORS
Specifications subject to change without notice. Installation must be in accordance with local codes and regulations.
NaturalDirect Spark1/2 inch NPT3/4 inch NPT
Gas (specify) Ignition system: solid state Gas connection size Condensate connection size
GAS CONTROLS AND ADDITIONAL DATA
ELECTRICAL DATA
SPECIFICATIONS BELOW ARE THE SAME FOR FOR STANDARD AND H SERIES
Volts/Phase/Cycle 208/230-1-60 Minimum Circuit Ampacity 13.3
1514.920
17.825
21.630
25.240 Maximum Fuse/HACR breaker size
DYPA12 DYPA18 DYPA24 DYPA30 DYPA36 MODEL
Fully Self-Contained Heating and Cooling System
Air Exhaust by Condenser Fan
Grille Mounts Flush to Outside Wall
Back View of DynaPack with Sleeve/Grille Attached
Air Intake To Condenser Coil
Optional Grille Colors Available
DynaPack: The Cost Effective Alternative To Condition Multiple Rooms.Featuring 1 to 3 Tons Cooling and Efficient 36 to 60 MBTU Gas Heat.
No Outside Condensing Unit
Five-Speed ECM Motor for Higher Efficiency and Maintaining a
Programmed and Proper Airflow
R410a Refrigerant
Direct Vent System
Insulated 16 GA Coated Galvanized Steel Base Pan Eliminates Need for Field
Added Platform
Individually Metered and Controlled
Pre-Wired and Pre-Charged
at the Factory
One Unit May be Ductedfor Multiple Room
Conditioning
Easy To Install In Almost Any Application
Internal Washable Filter/ Optional MERV13 filter
S Series - 80% AFUEH Series - 90%+ AFUE
..............................
Ideal for Multi-Family Applications.
............
The standard wall sleeve fits a 4 inch wall thickness and includes the option to expand to a 6”, 8”, 10”, 12”, 14”, 16”, 17”, 18”, 20” and 22” size.
Flexible-Depth Wall Sleeve Design
Reversible drain pan collects rain water that can be drained internally or externally.