105
SUBSTITUTION CSI Form 1.5C REQUEST (During the Bid Period) Substitution Request Number: Project: From: Date: To: A/E Project Number: Contract For: Re: © Copyright 2007, Construction Specifications Institute, 110 South Union Street, Suite 100, Alexandria, VA 22314 Page 1 Form Version: June 2004 CSI Form 1.5C This is not an official CSI Construction Contract Administration (CCA) Form. Please use CSI's official CCA Forms if required by your project needs. Specification Title: Description: Section: Page: Article/Paragraph: Proposed Substitution: Manufacturer: Address: Phone: Trade Name: Model No.: Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified. Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation. The Undersigned certifies: Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product. Same warranty will be furnished for proposed substitution as for specified product. Same maintenance service and source of replacement parts, as applicable, is available. Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule. Proposed substitution does not affect dimensions and functional clearances. Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the substitution. Submitted by: Signed by: Firm: Address: Telephone: A/E’s REVIEW AND ACTION Substitution approved - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures. Substitution approved as noted - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures. Substitution rejected - Use specified materials. Substitution Request received too late - Use specified materials. Signed by: Date: Supporting Data Attached: Drawings Product Data Samples Tests Reports ANTHC Patient Housing and Sky Bridge project Annie Messer Myron Gracey 11/24/14 Substitution request for Aluminum Composite Panels 07 42 23 Aluminum composite material wall panels Aluminum composite fire rated panels 2.1 1-2 Vitrabond Aluminum Composite Panels "FR" Fairview Architectural 68 E Dudleytown Rd Vitrabond ACM 860 242 2711 4mm FR or 6mm FR Myron Gracey Myron J Gracey Fairview Architectural 68 E Dudleytown Rd Bloomfield, CT 06002 860. 242. 2711

SUBSTITUTION CSI Form 1.5C REQUEST

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: SUBSTITUTION CSI Form 1.5C REQUEST

SUBSTITUTION CSI Form 1.5C REQUEST

(During the Bid Period)

Substitution Request Number: Project: From: Date: To: A/E Project Number: Contract For: Re:

© Copyright 2007, Construction Specifications Institute, 110 South Union Street, Suite 100, Alexandria, VA 22314

Page 1 Form Version: June 2004 CSI Form 1.5C

This is not an official CSI Construction Contract Administration (CCA) Form. Please use CSI's official CCA Forms if required by your project needs.

Specification Title: Description: Section: Page: Article/Paragraph:

Proposed Substitution: Manufacturer: Address: Phone: Trade Name: Model No.: Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified. Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation.

The Undersigned certifies: • Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product. • Same warranty will be furnished for proposed substitution as for specified product. • Same maintenance service and source of replacement parts, as applicable, is available. • Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule. • Proposed substitution does not affect dimensions and functional clearances. • Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the

substitution.

Submitted by:

Signed by:

Firm:

Address:

Telephone:

A/E’s REVIEW AND ACTION

Substitution approved - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures. Substitution approved as noted - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures. Substitution rejected - Use specified materials. Substitution Request received too late - Use specified materials.

Signed by: Date:

Supporting Data Attached: Drawings Product Data Samples Tests Reports

ANTHC Patient Housing and Sky Bridge project

Annie Messer

Myron Gracey

11/24/14

Substitution request for Aluminum Composite Panels

07 42 23

Aluminum composite material wall panels Aluminum composite fire rated panels

2.11-2

Vitrabond Aluminum Composite Panels "FR"Fairview Architectural 68 E Dudleytown Rd

Vitrabond ACM

860 242 2711

4mm FR or 6mm FR

Myron Gracey

Myron J Gracey

Fairview Architectural

68 E Dudleytown Rd

Bloomfield, CT 06002

860. 242. 2711

amesser
Text Box
Substitution request #13, 13 pages
Page 2: SUBSTITUTION CSI Form 1.5C REQUEST

VITRABOND Composite Metal Panel • VITRASPAN Insulated Metal Panel • SONICPANEL Non-Combustible Honeycomb Panel

Fairview Architectural LLC

68 E Dudleytown Rd

Bloomfield CT 06002

P: +1 860 242 2711

F: +1 860 242 3188

Vitrabond Technical Data

General Properties

THICKNESS PE/FR 3mm – 10mm (custom thicknesses available)

UNIT WEIGHT PE

FR

3mm: 0.94 lbs/sf; 4mm: 1.14 lbs/sf; 6mm: 1.49 lbs/sf

3mm: 1.17 lbs/sf; 4mm: 1.45 lbs/sf; 6mm: 1.95 lbs/sf

NOMINAL PANEL SIZES PE/FR WIDTH: 24”, 32”, 48”, 50”, 62”, 72”, 80”

LENGTH: 196” standard, any length available (subject to handling constraints)

PANEL CONSTITUTION PE/FR 0.5mm AL skins, with Anti-Toxic LDPE core (Black) or mineral-filled Fire Resistant

core (White)

TOLERANCES PE/FR Length: +- 4mm Width: +-2mm Thickness:+-0.2mm (over 4mm +-0.3mm)

Bow: Max 0.5% length / width Squareness: Max 5mm

GRADE OF ALUMINUM PE/FR A3105 H16, A3003 H16, or A5005 H16 series supplied by ALCAN

COATING SYSTEM PE/FR Kynar500 based PVDF or FEVE (exterior grade) supplied by PPG or Becker

COATING METHOD PE/FR Coil Coating

CORROSION RESISTANCE PE/FR ‘AA’ + Extra protection coating on the back side of panel.

COATING THICKNESS PE/FR 25-33 Microns

SOUND INSULATION PE/FR R = 250Hz: 19.7dB

Physical Properties

BONDING METHOD PE/FR Heat-Activated Film in a continuous fusion process

FLEXURAL ELASTICITY ASTM C-393 PE

FR

3mm: 0.71x106psi; 4mm: 4.57x106psi; 6mm: 4.22x106psi

4mm: 5.21x106psi;

TENSILE STRENGTH ASTM E 8 PE

FR

3mm: 8,803psi; 4mm: 7,085psi; 6mm: 4,970psi

4mm: 7,525psi;

YIELD STRENGTH ASTM E 8 PE

FR

3mm: 8,377psi; 4mm: 5,552psi; 6mm: 4,402psi

4mm: 6,247psi

PEEL STRENGTH ASTM D 1781 PE/FR Minimum 22.5 in-/lb/in (100 n-mm/mm)

ELONGATION ASTM E 8 PE

FR

3mm: 12%; 4mm:7.3%; 6mm: 17%

4mm: 4.1%

THERMAL EXPANSION ASTM D696 PE/FR 1.39x10¯5 in/in/°F (2.50x10¯5 mm/mm/°C)

THERMAL CONDUCTIVITY ASTM D976 PE/FR 0.387 Kcal/mhr°C

DEFLECTION TEMPERATURE ASTM D648 PE/FR 240°F

Other

STEINER TUNNEL TEST ASTM E 84 FR Class A (up to 8mm thick)

FIRE PROPAGATION FULL SCALE TEST

NFPA 285

FR Pass

WARRANTY PE/FR Up to 20 Years Material & Bonding

Up to 30 years on finish

Architect Approval Stamp

Page 3: SUBSTITUTION CSI Form 1.5C REQUEST

VITRABOND Composite Metal Panel • VITRASPAN Insulated Metal Panel • SONICPANEL Non-Combustible Honeycomb Panel

Fairview Architectural LLC

68 E Dudleytown Rd

Bloomfield CT 06002

P: +1 860 242 2711

F: +1 860 242 3188

Vitrabond Technical Data

General Properties

THICKNESS PE/FR 3mm – 10mm (custom thicknesses available)

UNIT WEIGHT PE

FR

3mm: 0.94 lbs/sf; 4mm: 1.14 lbs/sf; 6mm: 1.49 lbs/sf

3mm: 1.17 lbs/sf; 4mm: 1.45 lbs/sf; 6mm: 1.95 lbs/sf

NOMINAL PANEL SIZES PE/FR WIDTH: 24”, 32”, 48”, 50”, 62”, 72”, 80”

LENGTH: 196” standard, any length available (subject to handling constraints)

PANEL CONSTITUTION PE/FR 0.5mm AL skins, with Anti-Toxic LDPE core (Black) or mineral-filled Fire Resistant

core (White)

TOLERANCES PE/FR Length: +- 4mm Width: +-2mm Thickness:+-0.2mm (over 4mm +-0.3mm)

Bow: Max 0.5% length / width Squareness: Max 5mm

GRADE OF ALUMINUM PE/FR A3105 H16, A3003 H16, or A5005 H16 series supplied by ALCAN

COATING SYSTEM PE/FR Kynar500 based PVDF or FEVE (exterior grade) supplied by PPG or Becker

COATING METHOD PE/FR Coil Coating

CORROSION RESISTANCE PE/FR ‘AA’ + Extra protection coating on the back side of panel.

COATING THICKNESS PE/FR 25-33 Microns

SOUND INSULATION PE/FR R = 250Hz: 19.7dB

Physical Properties

BONDING METHOD PE/FR Heat-Activated Film in a continuous fusion process

FLEXURAL ELASTICITY ASTM C-393 PE

FR

3mm: 0.71x106psi; 4mm: 4.57x106psi; 6mm: 4.22x106psi

4mm: 5.21x106psi;

TENSILE STRENGTH ASTM E 8 PE

FR

3mm: 8,803psi; 4mm: 7,085psi; 6mm: 4,970psi

4mm: 7,525psi;

YIELD STRENGTH ASTM E 8 PE

FR

3mm: 8,377psi; 4mm: 5,552psi; 6mm: 4,402psi

4mm: 6,247psi

PEEL STRENGTH ASTM D 1781 PE/FR Minimum 22.5 in-/lb/in (100 n-mm/mm)

ELONGATION ASTM E 8 PE

FR

3mm: 12%; 4mm:7.3%; 6mm: 17%

4mm: 4.1%

THERMAL EXPANSION ASTM D696 PE/FR 1.39x10¯5 in/in/°F (2.50x10¯5 mm/mm/°C)

THERMAL CONDUCTIVITY ASTM D976 PE/FR 0.387 Kcal/mhr°C

DEFLECTION TEMPERATURE ASTM D648 PE/FR 240°F

Other

STEINER TUNNEL TEST ASTM E 84 FR Class A (up to 8mm thick)

FIRE PROPAGATION FULL SCALE TEST

NFPA 285

FR Pass

WARRANTY PE/FR Up to 20 Years Material & Bonding

Up to 30 years on finish

Architect Approval Stamp

Page 4: SUBSTITUTION CSI Form 1.5C REQUEST

110% Stock and Color Policy.

When the quantities, sheet sizes and color requirements for your project are received, 110% of the

material required for your project (up to 2,000sf extra per color!) is reserved in our warehouse, so that

the fabricator can draw on the material as needed. This material, is set aside until the project is

completed.

Ensures color consistency for the entire project

Keeps the project costs down (instead of the fabricator buying extra, and the material getting

marked up as it goes through each step of the construction process)

Quick access to material from the same batch for change orders, on-site damage repairs, etc…

Applies to standard and custom colors, in any quantity!

Page 5: SUBSTITUTION CSI Form 1.5C REQUEST

Color Chart

Edition: 6www.vitrabond.com

Page 6: SUBSTITUTION CSI Form 1.5C REQUEST

WorKING WIth VItraBoND

Vitrabond can be machined and shaped using extremely simple techniques and equipment.

VITRABOND is a light weight composite metal panel cladding material, and boasts the widest variety of surfaces and finishes in the industry. By fusing metal skins to a composite core in a continuous coil manufacturing process, VITRABOND achieves an exceptional degree of strength and durability.VITRABOND is well established in the market with a long track record of consistency, reliability and cost effectiveness, and is recognized by Architects, Builders and Installers worldwide as the superior cladding solution. With our dedicated customer support staff and our continual product development, we are readily available to meet your requirements.

KEY BENEFItS oF VItraBoND

• Highly durable PVDF fluoropolymer Kynar 500 coating system.

• Unlimited custom colors with no MOQ (We can match any PMS, Pantone, Paint, Powder coat)*

• Compatible with all attachment systems on the market that are designed for aluminum composite panel.

• 110% Stock & Color Policy - extra material in case you need it!• Peel-off protective film

tYPICal aPPlICatIoNS For VItraBoND

• Low Rise Architectural• High Rise Architectural• Canopies & Awnings• Interiors• Refurbishment• Curtain walls• Transportable buildings and

accommodation buildings.

VItraBoND & VItraBoND/FrALUMInUM COMPOSITe PAneL

CuttING

FolDING

ShEarING

CNC routING

roll-BENDING

ProFIlING

PuNChINGPErForatING

FaBrICatING

DrIllING

StaNDarD ShEEt SIzES

• Custom Widths available from 24” to 80”• Available up to 10mm think

*Please note:• not all colors are stocked in all sizes.• For non-stock orders we can produce custom sizing.

Please call Fairview to check availability.

110% StoCK & Color PolICY

When the quantities, sheet sizes and color requirements for your project are received, 110% of the material required for your project (up to 2,000sf extra per color!) is reserved in our warehouse, so that the fabricator can draw on the material as needed. This material is set aside until the project is completed, which ensures color consistency for the entire project and reduces waste factor costs!

WIDTHS (“) LengTHS (“)

40

122

146

196

50

122

146

196

62

122

146

196

Vitrabond is the most Versatile composite

panel aVailable!compatible with all attachment systems and wall assemblies!

www.vitrabond.com

Page 7: SUBSTITUTION CSI Form 1.5C REQUEST

VITRABOND Composite Metal Panel • VITRASPAN Insulated Metal Panel • SONICPANEL Non-Combustible Honeycomb Panel

Fairview Architectural LLC

68 E Dudleytown Rd

Bloomfield CT 06002

P: +1 860 242 2711

F: +1 860 242 3188

Vitrabond Finish Properties (PVDF Kynar500)

Dry Film Thickness (nominal)

ASTM D1400

0.20 – 0.30 mil primer

0.70 – 0.80 mil topcoat

Gloss

ASTM D523

Standard @ 60°: 25 - 35

DURANAR LG @ 85°: <10

Flexibility2

T-bend, ASTM D4145: 0-2 T-bend; No pick-off

Adhesion

ASTM D3359

No adhesion loss

Reverse impact 1/16” crosshatch

Reverse Impact

ASTM D2794

1.5 x metal thickness (aluminum) No cracking or

adhesion loss

Acid Resistance

ASTM D1308

10% muriatic acid — 24 hrs. No effect

20% sulfuric acid — 18 hrs. No effect

Acid Rain Test

Kesternich SO2, DIN 50018 15 cycles min.

No objectionable color change

Salt Spray Resistance

ASTM B117 Passes 4000 hrs.

5% salt fog @ 95°F Less than 1/16” avg.

creepage from scribe;

None or few #8 blisters

Humidity Resistance

ASTM D714, Passes 4000 hrs

ASTM D2247 No #8 blisters

100% relative humidity @ 95°F

Exterior Exposure

10 yrs. @ 45°, south Florida

ASTM D2244 Max. 5 fade

ASTM D4214 Max. 8 chalk

Alkali Resistance

ASTM D1308 No effect

10%, 25% NaOH, 1 hr.

Pencil Hardness

ASTM D3363: F-2H

Architect Approval Stamp

Page 8: SUBSTITUTION CSI Form 1.5C REQUEST

VItraBoNDCOLOR RAngeExPrESS raNGE

SPECIal orDEr

These are the most common colors, and are maintained in inventory for quick delivery**Note: While we strive to maintain sufficient inventory for all of our clients, we cannot guarantee that all colors and sheet sizes will be available on short notice. We recommend you contact us in advance about the project so that we can ensure stock availability in the colors and sizes that you need.

Vitrabond has the broadest range of colors and finishes in the industry, some of which are included in our “Special Order” range on the following pages. Some of these finishes may be in stock - please call for availability. Unlimited custom colors and finishes available

MEtallICa MeTALLIC COLORS

VItra Fx SPeCIAL eFFeCTS COLORS

VItraCrEatE WOOD & STOne FInISHeS

VItraBoND UnLIMITeD COLORS

NaturalINE nATURAL MeTAL FInISHeS

ClaSSICo SOLID COLORS

www.vitrabond.com All colors in this color chart are to be used as a guide only. The color accuracy is subject to the calibration of your monitor and the limitations of your printer. For exact colors, please request a physical sample.

Page 9: SUBSTITUTION CSI Form 1.5C REQUEST

MEtallICa - MeTALLIC COLORS

ExPrESS raNGE

BRIgHT SILVeR MeTALLIC VB9801

gOLD MeTALLIC VB4150

COPPeR MeTALLIC VB9809

ASCOT WHITe VB9210

gReYSTAneS VB9304

WHITe VB9902

BLACK VB9130

SILVeR MeTALLIC VB9601

SMOKe SILVeR MeTALLIC VB9134

CHAMPAgne MeTALLIC VB9205

BeLLeReVe BAY VB9107

OFF WHITe VB9702

SILVeR ICe MeTALLIC VB9701

DARK gReY MeTALLIC VB9137

BROnZe MeTALLIC VB9308

LAKe FROMe VB9504

FRAnKSTOn VB9103

ClaSSICo - SOLID COLORS

www.vitrabond.com All colors in this color chart are to be used as a guide only. The color accuracy is subject to the calibration of your monitor and the limitations of your printer. For exact colors, please request a physical sample.

Page 10: SUBSTITUTION CSI Form 1.5C REQUEST

ClaSSICo - SOLID COLORS

VInTAge gReen VB1530

RUBIS ReD VB1685

BAKOS BLUe VB1490

BRIMSTOne VB9011

PeARL WHITe gLOSS VB1025

STROng SAge VB1585

TACUMA BAY VB9802

LOWeSDALe VB9061

AIRPORT WHITe SATIn VB1005

AnTHRAZIT gReY VB1255

BRIgHT ORAnge VB1190

BOAT HARBOUR VB9207

PURe APPLe VB1550

CAPSICUM ReD VB1690

RAILWAY OFF WHITe VB1090

LeMOn YeLLOW VB1120 BROWn COAL VB9108

BeIge VB1310

gRAPHITe ReD VB9477

ULTRAMARIne BLUe VB1460

FAIRVIeW gReen VB9212

VItraBoND - UnLIMITeD COLORS!

SPECIal orDEr

www.vitrabond.com All colors in this color chart are to be used as a guide only. The color accuracy is subject to the calibration of your monitor and the limitations of your printer. For exact colors, please request a physical sample.

Page 11: SUBSTITUTION CSI Form 1.5C REQUEST

NaturalINE - nATURAL MeTAL FInISHeS

www.vitrabond.com All colors in this color chart are to be used as a guide only. The color accuracy is subject to the calibration of your monitor and the limitations of your printer. For exact colors, please request a physical sample.

SPECIal orDEr

MIRROR FInISH VB5800 HAIRLIne FInISH VB5850 OPAQUe FInISH VB5755

CCOOPPPPEERR

WEATHERED COPPER – C02

PATINA COPPER – C03

BBRRAASSSS // BBRROONNZZEE

BRUSHED BRASS – B01

BRUSHED BRONZE – B03

ZZIINNCC

BRUSHeD BRASS VB5115AnODIZeD CROSS BRUSHeD VB5848

FAUx CORTen VB5360

AnODIZeD BRILLIAnT MIRROR VB5801 AnODIZeD BRUSHeD VB5845

CCOOPPPPEERR

WEATHERED COPPER – C02

PATINA COPPER – C03

BBRRAASSSS // BBRROONNZZEE

BRUSHED BRASS – B01

BRUSHED BRONZE – B03

ZZIINNCC

BLUe gReY VB5740 gRAPHITe gReY VB5225

CCOOPPPPEERR

WEATHERED COPPER – C02

PATINA COPPER – C03

BBRRAASSSS // BBRROONNZZEE

BRUSHED BRASS – B01

BRUSHED BRONZE – B03

ZZIINNCC

QUARTZ gReY VB5210 AnTHRACITe gReY VB5290

FAUx ZInC DARK VB5220

BRUSHeD ALUMInUM VB5855

Faux - ReALISTIC FInISHeS

natural Zinc natural Zinc

aluminumstainless steel

natural Zinc natural Zinc

nATURAL COPPeR VB5160natural copper

CCOOPPPPEERR

WEATHERED COPPER – C02

PATINA COPPER – C03

BBRRAASSSS // BBRROONNZZEE

BRUSHED BRASS – B01

BRUSHED BRONZE – B03

ZZIINNCC

WeATHeReD COPPeR VB5365natural copper

CCOOPPPPEERR

WEATHERED COPPER – C02

PATINA COPPER – C03

BBRRAASSSS // BBRROONNZZEE

BRUSHED BRASS – B01

BRUSHED BRONZE – B03

ZZIINNCC

PATInA COPPeR VB5570natural copper

CCOOPPPPEERR

WEATHERED COPPER – C02

PATINA COPPER – C03

BBRRAASSSS // BBRROONNZZEE

BRUSHED BRASS – B01

BRUSHED BRONZE – B03

ZZIINNCC

BRUSHeD BROnZe VB5185natural bronze

natural brassanodized aluminum

FAUx ZInC LIgHT VB5790aluminum

FFAAUUXX--ZZIINNCC

FAUX-ZINC – 404

FAUX-ZINC – 408

FAUX-ZINC – 406

FFAAUUXX--CCOOPPPPEERR

FAUX-COPPER PATINA – 407

FAUX-COPPER PATINA – 405

This Color Chart is a representation only. Actual colors may vary. v 2012.11

FAUx ZInC CHARCOAL VB5260aluminum

stainless steel

aluminum

anodized aluminum

aluminum

stainless steel

anodized aluminum

Page 12: SUBSTITUTION CSI Form 1.5C REQUEST

CHROMATIC PURPLe VB7450 CHROMATIC TIgeR VB7180 JADe MeTALLIC VB9031 SPARKLIng BLACK VB7295

SPARKLIng BLUe VB7470 SPARKLIng ReD VB7650 SPARKLIng WHITe VB7020

VItra Fx - SPeCIAL eFFeCT COLORS (Other special effect finishes also available)

SPECIal orDEr

SPARKLIng DARK gReY MeTALLIC VB7250

AMeRICAn PIne VB8330 gOLDen CeDAR VB8165 TeAK VB8350 DARK OAK VB8388

WooDCrEatE - WOOD gRAIn FInISHeS (Other wood grain finishes also available)

WHITe MARBLe VB6060 gReen MARBLe VB6575 BROWn MARBLe VB6380 BLACK gRAnITe VB6250

StoNECrEatE - nATURAL STOne (Other stone finishes also available)

www.vitrabond.com All colors in this color chart are to be used as a guide only. The color accuracy is subject to the calibration of your monitor and the limitations of your printer. For exact colors, please request a physical sample.

Page 13: SUBSTITUTION CSI Form 1.5C REQUEST

MAnUFACTUReD & SUPPLIeD BY:

AUSTRALASIA HeAD OFFICe:P: +61 2 6352 2355

nORTH AMeRICA:P: +1 860 242 2711

UnITeD KIngDOM:P: 0844 800 7131

E: [email protected]

www.fairviewarchitectural.com

www.vitrabond.com

Page 14: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1-800-426-7737 www.firestonemetal.com

Delta Series CFP·12 Panel Index 12· HO CONCEALED FASTENED PANELS

·,

~~ ~.••........

o BASE DETAILS e HORIZONTAL JOINT DETAIL e PARAPET ROOF DETAIL o INSIDE CORNER DETAIL

• OUTSIDE CORNER DETAIL

• SOFFIT DETAIL

8 WINDOW JAMB DETAIL o WINDOW HEAD DETAIL

o WINDOW SILL DETAIL

G> TRANSITION OPTIONS

HORIZONTAL PANELS

REFERENCE SHEETS

HO.1 - PANEL PROFILE INFORMATION

HA.1 - WINDOW OPENING ISOMETRIC

HA.2 ­ PENETRATION ISOMETRIC

HB.1 - PANEL I PANEL OVERLAP SPLICE

EACH DETAIL CONSISTS OF TWO DIFFERENT WALL CAVITY ASSEMBLIES; INSULATED AND NON-INSULATED.

IE: DETAIL CD ON THE ELEVATION WILL BE REPRESENTED BY TWO SHEETS 1.1 AND 1.2 ILLUSTRATING EACH RESPECTIVE WALL ASSEMBLY.

WALL TYPE 1 & 2 WALL ASSEMBLY DISSEMINATES GENERAL, BEST PRACTICE, RECOMMENDATION FOR USE OF AIR I VAPOR BARRIERS WITHIN U.S. DEPT. OF ENERGY CLIMATE ZONES

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

amesser
Text Box
Substitution request #15, 92 pages
Page 15: SUBSTITUTION CSI Form 1.5C REQUEST

",restone METAL PRODUCTS

1-800-426-7737 www.firestonemetal.com

Delta Series CFP·12 • PROFILE 12 • HO.1

ITEM NUMBER: CFP-12 NET COVERAGE: 12" (1' Oil) MAXIMUM LENGTH: (40 feet)

~ 12.000 (NET COVERAGE-jr 4.000 1 8.000~

-l ~ .813

-r

MATERIAL OPTIONS COIL ­ COATED STEEL COIL ­ COATED ALUMINUM ANODIZED ALUMINUM

FABRICATION OPTIONS STEEL: 18, 20, 22, 24 GAUGE ALUMINUM: .032" - .040"

FINISH OPTIONS PAINTING "COIL COATED"

HYLAR 5000 I KYNAR 500, MODIFIED POLYESTERS, AND OTHER CUSTOM OR EXOTIC FINISHES.

ANODIZING CLEAR, BRONZES, AND VARIOUS OTHER COLORS COIL ANODIZED FOR COLOR CONSISTENCY.

NOTES: 1. HEAVIER GAUGES MINIMIZE "OIL CANNING". 2. OIL CANNING IS NOT ACAUSE FOR REJECTION. 3. AN EXTENSIZE SELECTION OF ASSOCIATED PANEL FLASHING AND TRIMS ARE AVAILABLE. 4. CONTACT FSMP FOR UP TO DATE TECHINCAL INFORMATION AND MATERIAL LIMITATIONS. 5. ALL SYSTEMS WITH TESTING MUST BE INSTALLED IN ACCORDANCE WITH THE ASSEMBLY AS TESTED.

(jIIO.1) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 16: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • Base Detail 12 • H1.1 WALL ASSEMBLY TYPE 1

OVERALL WALL ASSEMBLY

FACE OF PANEL TO SHT'G

.813 CFP-12 21.0mm

HORIZONTAL PANELS

r#_+-- ----::>'"..:::.....-~---lil__-+--_EXTERIORSHEATHING WATER-RESISTIVE (BY OTHERS)

-------+t-----' BARRIER

(BY OTHERS)

STUD WALL CONTINUOUS '-f-'f---'---.+---(BY OTHERS)

'Z'GIRT (BY INSTALLER)

INSULATION 1/8" X 1" CONT ----t---It--+---R-VALUE TO CODE

NON CURRING (BY OTHERS)

BUTYL TAPE --~

(BY INSTALLER) INTERIOR DRYWALL

FASTENERS TYP. (BY OTHERS) (BY INSTALLER)

VAPOR BARRIER "OPTIONAL" I..--...,.,.--'-t---(BY OTHERS)

BUTYL / HOTMELT SEALANT ----tlr-t1rt-flll

(FACTORY OR FIELD APPLIED)

SEAL or TAPE EDGESPRE FINISHED CONTINUOUS AND ALLBASE FLASHING

f:"""'T7tIf----------=::.....::----~-I------+--PENETRATIONS PER(BY INSTALLER)

MANUF. RECOMMENDATIONS <J (BY INSTALLER)

L1 L1WEEP TUBE

<J CONCRETE& BAFFLE

PRECAST (BY INSTALLER)

IMPROVE ENERGY EFFICIENCY WITH PROPER COMPONENT WALL ASSEMBLIES IN MOST REGIONS, EXTERIOR WALLS HAVING INSULATION INSIDE THE STUD WALL CAVITY SHOULD USE AVAPOR-PERMEABLE MEMBRANE APPLIED ON THE EXTERIOR SIDE OF THE WALL. AVAPOR-PERMEABLE MEMBRANE ALLOWS THE WALL CAVITY TO BREATH AND DRY POTENTIAL MOISTU RE CAUSED FROM VAPOR PRESSU RE. IN COLDER CLIMATES A NON-PERMEABLE VAPOR BARRIER MUST BE INSTALLED ON THE INTERIOR SIDE OF THE WALL ASSEMBLY TO MINIMIZE OUTWARD VAPOR PRESSURE CAUSED BY HEATED AND HUMIDIFIED INTERIOR ENVIRONMENTS DURING THE COLD SEASON.

2006 INTERNATIONAL BUILDING CODE -1403.2 WEATHER PROTECTION: EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTIVE BARRIER ON THE SIDE OF THE WALL BEHIND THE EXTERIOR VANEER. PROVIDE MEANS OF DRAINING WATER THAT ENTERS BETWEEN THE EXTERIOR VANEER AND THE WATER-RESISTANT BARRIER.

t!1.1) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 17: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1-800-426-7737 www..firestonemetal.com

Delta Series CFP·12 • Base Detail 12 • H1.2 WALL ASSEMBLY TYPE 2

OVERALL WALL ASSEMBLY

FACE OF PANE

.813 21.0mm

TO SHT'G .500" MIN AIR SPACE

12.7mm I

VAPOR BARRIER "OPTIONAL"

(BY OTHERS)

INTERIOR DRYWALL (BY OTHERS)

<J

STUD WALL __-4-1-~-+--~

(BY OTHERS)

/I

.L\

<J CONCRETE

/~+---I--------=:::""":::----+----ft~-+-- EXTERIOR SHEATHING (BY OTHERS)

INSULATION --,~~'+I----+--------:::>","7--=~----II---1--- R-VALUE TO CODE

(BY OTHERS)

- WEEP TUBE & BAFFLE (BY INSTALLER)

I I

SEAL or TAPE EDGES CONTINUOUS AND ALL

~...L..-.:.~~~t4S:W-------'::::::::"=---------:;4I---J-- PENETRATIONS PER MANUF. RECOMMENDATIONS (BY INSTALLER)

PRECAST .' SEALANT

(BY INSTALLER)

FASTENERS TYP. II

(BY INSTALLER)

BUTYL I HOTMELT SEALANT

(FACTORY OR FIELD APPLIED)

WATER-RESISTIVE BARRIER ----l+----+----1'-<--~.,---~-:JI1/

(BY OTHERS)

CFP-12 HORIZONTAL ----1-1

PANELS

CONTINUOUS 'Z'GIRT

(BY INSTALLER) ----l+----+-­

1/8" x1" CONT NON CURRING

BUTYL TAPE ----l+----+---1-~-~~

(BY INSTALLER)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 18: SUBSTITUTION CSI Form 1.5C REQUEST

----1--1-111------.+--- R-VALUE TO CODE

~-"'\"""""<:....-...JII-.-',---.--'-l----

,.loo,41-+--1-_----=::_---+-----flll----+--EXTERIOR SHEATHING

T7/'Tr--l-----::::::...:::----::::!>.L---II-~+_-

HORIZONTAL------II

HORIZONTAL----11

BARRIER ----it-----¥

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • Seam Detail 12 · H2.1 WALL ASSEMBLY TYPE 1

WATER-RESISTIVE

(BY OTHERS)

CFP-12

PANELS

FASTENERS TYP. (BY INSTALLER)

BUTYL / HOTMELT SEALANT

(FACTORY OR FIELD APPLIED)

CONTINUOUS HAT CHANNEL

(BY INSTALLER)

CFP-12

PANELS

FACE OF PANEL TO SHT'G

(BY OTHERS)

INSULATION

(BY OTHERS)

STUD WALL (BY OTHERS)

1/8" x1" CONT NON CURRING BUTYL TAPE (BY INSTALLER)

INTERIOR DRYWALL --(BY OTHERS)

VAPOR BARRIER 1--"'-:..-+-- "OPTIONAL"

(BY OTHERS)

.813 I 21.0mm l

I I

OVERALL WALL ASSEMBLY

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 19: SUBSTITUTION CSI Form 1.5C REQUEST

",restone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • Seam Detail 12 • H2.2 WALL ASSEMBLY TYPE 2

CFP-12 HORIZONTAL----II

PANELS

WATER-RESISTIVE BARRIER

(BY OTHERS)

CONTINUOUS 'z' GIRT ----H------,.

(BY INSTALLER)

FASTENERS TYP. (BY INSTALLER)

BUTYL / HOTMELT SEALANT

(FACTORY OR FIELD APPLIED)

CFP-12 HORIZONTAL

PANELS---~I

'I 1/8" x 1" CONT r-------:::"""::----+-----flfI--""'"""-t--- NON CURRING

BUTYL TAPE (BY INSTALLER)

STUD WALL f----flt:---,,---+-- (BY OTHERS)

LOCALIZED MEMBRANE ~-'!!IIf,.L,"'-,#-'..------+-------::"..::::.......--+-~--+-- (BY INSTALLER)

/~_+-__---="",,,=-_~<........ffI-.,.......;-+-_EXTERIORSHEATHING (BY OTHERS)

INSULATION ~~~4f--+------:>"'----=::~--+~-111----+-- R-VALUE TO CODE

(BY OTHERS)

INTERIOR DRYWALL (BY OTHERS)

VAPOR BARRIER l.__.--+-- "OPTIONAL"

(BY OTHERS)

.813 .500 MIN AIR SPACE 21.0 mm 12.7 mm

FACE OF PANEL TO SHT'G

OVERALL WALL ASSEMBLY

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (BOO) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 20: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1-800-426-7737 www.firestonemetal.com

Delta Series CFP·12 • Seam Detail 12 · H2.3 WALL ASSEMBLY TYPE 1

INTERIOR DRYWALL .--(BY OTHERS)

VAPOR BARRIER 11--'-..-+-- "OPTIONAL"

(BY OTHERS)

INSULATION ~---/-r---tt-'-----'-+---- R-VALUE TO CODE

(BY OTHERS)

STUD WALL --+----ftI-"""-,,--+--- (BY OTHERS)

1/8" x1" ~------=:::"~--t::::::"'''-------1fr--------t--- NON CURRING

BUTYL TAPE (BY INSTALLER)

EXTERIOR SHEATHING ~-+--+------::....,......----+-----+HI--_+_--

(BY OTHERS)

CFp·UNA25 ,.\"Ir-t7"":;>4t------;"----~____:::::,..L--_+_---'---'t__-HANGER CLIP

(BY INSTALLER)

CFP-12 HORIZONTAL-----II

PANELS

CFP-12 HORIZONTAL----li

PANELS

FASTENERS TYP. (BY INSTALLER)

WATER-RESISTIVE BARRIER----It-------v

(BY OTHERS)

BUTYL / HOTMELT SEALANT

(FACTORY OR FIELD APPLIED)

FACE OF PANEL

.813 I 21.0mm

I TO SHT'G I

OVERALL WALL ASSEMBLY

112.$ HANGER CLIP OPTION Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 21: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1-800-426-7737 www.firestonemetal.com

Delta Series CFP·12 • Seam Detail 12 • H2.4 WALL ASSEMBLY TYPE 1

INTERIOR DRYWALL -­(BY OTHERS)

VAPOR BARRIER 11--'-':-"+-­ "OPTIONAL"

(BY OTHERS)

INSULATION ____--+-~-iI'-"'----'-+-- R-VALUE TO CODE

(BY OTHERS)

___+----.LtI-_-+-__STUD WALL (BY OTHERS)

1/8" x1" ~--':::""':::------t~-;II--'--jr--- NON CURRING

BUTYL TAPE (BY INSTALLER)

rorHl-+--+-_~~--_+_---ffft---+--_EXTERIOR SHEATHING (BY OTHERS)

-fi£rrt'if---+-----.....::::......::---+-~I---+---1/4" SHIM (BY INSTALLER)

CFP-12 HORIZONTAL ------0-11

PANELS

CFP-12 HORIZONTAL ------0-11

PANELS

FASTENERS TYP. -(BY INSTALLER)

WATER-RESISTIVE --l+-__--V

BARRIER (BY OTHERS)

BUTYL 1HOTMELT SEALANT

(FACTORY OR FIELD APPLIED)

FACE OF PANEL

.813 I 21.0mm

l I TO SHTG I

OVERALL WALL ASSEMBLY

~ DIRECT FASTEN OPTION Copyright 2011© FIRESTONE METAL PRODUCTS

fOOl Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 22: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1-800-426-7737 www..firestonemetal.com

Delta Series CFP·12 • Parapet Roof Detail 12 • H3.1 WALL ASSEMBLY TYPE 1

ROOFING MEMBRANE (BY INSTALLER)

1-4Io-_FIRE RATED PLYWOOD (BY OTHERS)

I-+l-j....I....j;...__VAPOR BARRIER "OPTIONAL" (BY OTHERS)

___--IJ.I-- WOOD BLOCKING (BY OTHERS)

__~===II++++-h-__STUD WALL (BY OTHERS)

/*_...l....­ ---l-------J~++-lll--_EXTERIORSHEATHING (BY OTHERS)

'J' FLASHING (BY INSTALLER) ----......

r--- LOCALIZED MEMBRANE PRE FINISHED (BY INSTALLER)

COPING -----Jr,----lt~-~-~=~=~-:-~" ~;:;:;~~;:;:;~~~~~(BY INSTALLER) II ----------­ _

I: II II II II

~-~-:-:-:-:-:.J~I~1F~~~~~~~~~tRtI~SEAL or TAPE EDGES1/8" x1" CONT;; CONTINUOUS AND ALL

NON CURRING ---...."..-----lIifII1 PENETRATIONS PER BUTYL TAPE MANUF. RECOMMENDATIONS (BY INSTALLER) (BY INSTALLER)

FASTENERS TYP. 1m,

(BY INSTALLER)

WATER-RESISTIVE -----It-------I/ BARRIER

(BY OTHERS)

CFP-12 HORIZONTAL -----II

PANELS

FACE OF PANEL TO SHT'G

.813 21.0mm

OVERALL WALL ASSEMBLY

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 23: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 · Parapet Roof Detail 12 • H3.2 WALL ASSEMBLY TYPE 2

ROOFING MEMBRANE (BY INSTALLER)

LOCALIZED ~ f~-=-===== ." MEMBRANE '! I - - 7-~==-=~~::.=.=~~

PRE FINISHED (BY INSTALLER) I: COPING ------+ 'J' FLASHING ::

(BY INSTALLER) (BY INSTALLER) J: 7.<fii7'971'~~=====~='fFR::ffi~

1/8" x 1" CONT NON CURRING

BUTYL TAPE (BY INSTALLER)

FASTENERS TYP. ---I-ll---~~~x~P~~ (BY INSTALLER) ~_-'---- ....l...-~I-+++++_

CFP-12----H--_ HORIZONTAL

PANELS

WATER·RESISTIVEBARRIER -----\l<:-----+~-----'''''04--~~-V

(BY OTHERS)

.813 .500 MIN AIR SPACE 21.0mm 12.7mm

FACE OF PANEL TO SHT'G

OVERALL WALL ASSEMBLY

SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS (BY INSTALLER)

STUD WALL (BY OTHERS)

EXTERIOR SHEATHING (BY OTHERS)

INSULATION R-VALUE TO CODE (BY OTHERS)

FIRE RATED PLYWOOD (BY OTHERS)

VAPOR BARRIER "OPTIONAL" (BY OTHERS)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fox (763) 576-9596

Page 24: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • Inside Corner Detail 12 • H4.1 WALL ASSEMBLY TYPE 1

= E8J5qciN 10

PRE FINISHED INSIDE CORNER

(BY INSTALLER)

FASTENERS TYP. _~ (BY INSTALLER)

CONTINUOUS HAT CHANNEL --~

(BY INSTALLER)

CFP-12 HORIZONTAL

-----_J

PANELS

WATER·RESISTIVE

1/8" x 1ft

NON CURRING /~------'>...,......-------+++........,....-.,.......f-- BUTYL TAPE

(BY INSTALLER)

INTERIOR DRYWALL (BY OTHERS)

INSULATION ---------;t-'--c--'--r- R-VALUE TO CODE

(BY OTHERS)

EXTERIOR SHEATHING

(BY OTHERS)

--,t-+------,,-+__ STUD WALL I (BY OTHERS)

I I I I I II

BARRIER -------f-----il-:---H-l

(BY OTHERS) ~813 I

_ -----, 21.0 mmFACE OF PANEL _ _ ,ITO SHT'G

OVERALL WALL ASSEMBLY ------.,;;,.-::....==:.....:....:..;==....:~=.;..,:=-=-.:....------J

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 25: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • Inside Corner Detail 12 • H4.2 WALL ASSEMBLY TYPE 2

PRE FINISHED INSIDE CORNER

(BY INSTALLER)

CONTINUOUS 'z' GIRT ----+------'~

(BY INSTALLER)

CFP-12 HORIZONTAL ----I

PANELS

WATER-RESISTIVE BARRIER ----+--~_+_-----''1f--~f----+i1'\.

(BY OTHERS)

INSULATION R-VALUE TO CODE (BY OTHERS)

EXTERIOR SHEATHING

(BY OTHERS)

STUD WALL (BY OTHERS)

1/8" X 1" CONT NON CURRING BUTYL TAPE (BY INSTALLER)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 26: SUBSTITUTION CSI Form 1.5C REQUEST

Tlrestone METAL PRODUCTS

1-800-426-7737 www.firestonemetal.com

Delta Series CFP·12 • Inside Corner Option 12 · H4.3 WALL ASSEMBLY TYPE 1

2.375" MIN

URETHANE SEALANT

ALUM EXTRUSION

1/8" x 1" CONT NON CURRING BUTYL TAPE (BY INSTALLER) -

1/8" x 1" CONT NON CURRING BUTYL TAPE (BY INSTALLER)

EXTRUDED CAPTURED 90° CORNER wI REVEAL CFP • HORIZONTAL PANELS· OPTION IAI

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 27: SUBSTITUTION CSI Form 1.5C REQUEST

Ytrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • Inside Corner Option 12 · H4.4 WALL ASSEMBLY TYPE 1

URETHANE SEALANT 2.000"

50.8mm

EXTRUDED CAPTURED 90° CORNER TRIM CFp· HORIZONTAL PANELS· OPTION IBI

Copyright 2011© FIRESTONE METAL PRODUCTS

7007 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 28: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • Inside Corner Option 12 • H4.5 WALL ASSEMBLY TYPE 1

FACTORY FABRICATED AND SEALED MITERED CORNER ASSEMBLY

1/8" x 1" ~~'--- :::...::::-__ NON CURRING

BUTYL TAPE (BY INSTALLER)

FORMED MITERED 900 INSIDE CORNER CFP· HORIZONTAL PANELS· OPTION 'C'

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (BOO) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 29: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1-800-426-7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • Outside Corner Detail 12· H5.1 OVERALL WALL ASSEMBLYWALL ASSEMBLY TYPE 1 ~

FACEOFPANEL__----1 __

TO SHT'G .813 21.0mm

II ----..!....:II-_-I----__ STUD WALL (BY OTHERS)II

II EXTERIORII SHEATHING

II (BY OTHERS)

II II INSULATION

---~.--tII--+--- R-VALUE TO CODE WATER-RESISTIVE (BY OTHERS): 'I

BARRIER ----1-----*'-----14. (BY OTHERS) VAPOR BARRIER

It:-.....;...j..--- "OPTIONAL" (BY OTHERS)

CFP-12 HORIZONTAL __----I ~-- INTERIOR DRYWALL

PANELS (BY OTHERS)

1/8" x 1" NON CURRING -1--_--11+-_-+1\­

BUTYL TAPE (BY INSTALLER)

CONTINUOUS ----1--.....

HAT CHANNEL (BY INSTALLER)

ATIACHTRIM W/BONDING TAPE

(BY INSTALLER)

PRE FINISHED OUTSIDE CORNER

(BY INSTALLER) --------~

METAL CLAD FOAM CLOSURE

I. CFP-123.000" HORIZONTAL76.2mm

PANELS

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 30: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • Outside Corner Detail 12 • H5.2 WALL ASSEMBLY TYPE 2 OVERALL WALL ASSEMBLY

FACE OF PANEL TO SHT'G

.500 MIN AIR SPACEI' 12.7mm I

.813 21.0mm EXTERIOR

,~----------tlf---+- SHEATHING (BY OTHERS)

I -----Hl----.,.---I--- STUD WALL

(BY OTHERS)

INSULATION ~-r-~~t--------?"":::..-..,.-----::,,-<---iII---'--+- R-VALUE TO CODE

(BY OTHERS)

VAPOR BARRIER II----,--f-- ·OPTIONAL"

(BY OTHERS)

INTERIOR DRYWALL (BY OTHERS)

WATER-RESISTIVE BARRIER -----+----lI~~~---P-.,--~H-l

(BY OTHERS)

CFP-12 HORIZONTAL ----I

PANELS

ATTACH TRIM W/BONDING TAPE

(BY INSTALLER)

PRE FINISHED OUTSIDE CORNER

(BY INSTALLER) ----I

METAL CLAD

I, FOAM CLOSURE CFP-12 J3.000" HORIZONTAL 76.2mm PANELS

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 31: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • Outside Corner Option 12 · H5.3 WALL ASSEMBLY ll'PE 1

= E °E8~ ~~

4.000" 101.6mm

EXTRUDED CAPTURED 90° CORNER wI FLAT FACE CFP· HORIZONTAL PANELS· OPTION IAI

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 32: SUBSTITUTION CSI Form 1.5C REQUEST

'Ftrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • Outside Corner Option 12 · H5.4 WALL ASSEMBLY TYPE 1

= E g~ ~ci N 10

I, 2.000" 50.8mm

URETHANE SEALANT

EXTRUDED CAPTURED 900 CORNER wi REVEAL CFP· HORIZONTAL PANELS· OPTION IBI

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fox (763) 576-9596

Page 33: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

12 • HS.S Delta Series CFP·12 • Outside Corner Option WALL ASSEMBLY TYPE 1

LCTORY FABRICATED AND SEALED MITERED CORNER ASSEMBLY

FACTORY APPLIED CORNER ANGLE

1/8" X 1" NON-CURRING BUTYL TAPE (BY INSTALLER)

FORMED MITERED 90° OUTSIDE CORNER CFp· HORIZONTAL PANELS· OPTION ·C·

(ills.$) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 34: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1-800-426-7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • Soffit Detail 12 • H6.1 WALL ASSEMBLY TYPE 1 OVERALL WALL ASSEMBLY

FACE OF PANEL ~~ TO SHT'G .813 "I21.0mm

WATER-RESISTIVE BARRIER ----ff------V

(BY OTHERS)

CFP-12 ---II HORIZONTAL

PANELS

SEAL or TAPE EDGES CONTINUOUS AND ALL

PENETRATIONS PER MANUF.

RECOMMENDATIONS -----It-----~I/ (BY INSTALLER)

1/8"x 1" CONT II

NON CURRING BUTYL TAPE (BY INSTALLER)

FASTENERS TYP.-__-H---L

(BY INSTALLER)

BUTYL / HOTMELT SEALANT

(FACTORY OR FIELD APPLIED)

5.000" 127.0mm

PRE FINISHED CONTINUOUS SOFFIT FLASHING 'J'SHAPE

(BY INSTALLER) (BY INSTALLER)

1-+-11--'-'--"""'+-__ STUD WALL (BY OTHERS)

INSULATION R-VALUE TO CODE (BY OTHERS)

INTERIOR DRYWALL -+--- (BY OTHERS)

VAPOR BARRIER "OPTIONAL"

(BY OTHERS)

CFP-12 EXTERIORHORIZONTAL SHEATHING

PANELS (BY OTHERS)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 35: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • Soffit Detail 12 • H6.2 WALL ASSEMBLY TYPE 2 OVERALL WALL ASSEMBLY

EXTERIOR SHEATHING

(BY OTHERS)

INTERIOR DRYWALL (BY OTHERS)

VAPOR BARRIER 111..------.,1--- "OPTIONAL"

(BY OTHERS)

CFP-12J HORIZONTAL

PANELS

STUD WALL _~-'---t--- (BY OTHERS)

FASTENERS TYP. (BY INSTALLER)

/~":+h~'I+------L..---~_=:I..~-+J--,----'-+-- INSULATION R-VALUE TO CODE (BY OTHERS)

FACE OF PANEL I TO SHT'G

.500 MIN AIR SPACE 12.7mm I

.813 21.0mm

CONTINUOUS 'z' GIRT -----1+------11

(BY INSTALLER)

WATER-RESISTIVE -----1H-----~-r-~-,L---'>,,--,"'I-I/

BARRIER (BY OTHERS)

CFP-12 HORIZONTAL ---II

PANELS

SEAL or TAPE EDGES CONTINUOUS AND ALL

PENETRATIONS PER ---H----~~~~~"""~~/ MANUF.

RECOMMENDATIONS (BY INSTALLER)

PRE FINISHED SOFFIT FLASHING

(BY INSTALLER)

BUTYL I HOTMELT SEALANT

(FACTORY OR FIELD APPLIED)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 36: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • Window Jamb Detail 12 • H7.1 WALL ASSEMBLY TYPE 1

WATER-RESISTIVE BARRIER ----------,

(BY OTHERS)

STUD WALL (BY OTHERS) ------,

EXTERIOR SHEATHING

(BY OTHERS)

INSULATION ,-----R-VALUE TO CODE

(BY OTHERS)

.---__ VAPOR BARRIER "OPTIONAL" (BY OTHERS)

INTERIOR DRYWALL (BY OTHERS)

LOCALIZED MEMBRANE

(BYOTHERSj

WINDOW/DOOR SYSTEM

(BYOTHERSj

PREFINISHED JAMB TRIM -------1

(BY INSTALLER)

ATIACHTRIM W/BONDING TAPE

(BY INSTALLER)

FASTENERS TYP. (BY INSTALLER)

CONTINUOUS HAT CHANNEL

(BY INSTALLER)

CFP-12 HORIZONTAL

PANELS

....J W

z'"rtF­u. I AU)

w Out­<C u.

~ CCl :E w U)

~ ....J ....J

~ ....J ....J

~ W >a

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 37: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • Window Jamb Detail 12 • H7.2 WALL ASSEMBLY TYPE 2

STUD WALL (BY OTHERS) --------,

,...-­ VAPOR BARRIER ·OPTIONAL" (BY OTHERS)

WATER-RESISTIVE BARRIER -~--,

(BY OTHERS)

EXTERIOR SHEATHING

(BY OTHERS)

.------ INTERIOR DRYWALL (BY OTHERS)

INSULATION R-VALUE TO CODE (BY OTHERS)

~ co ::::2: w (f)

~ .....J .....J

~ .....J .....J

~ W >o

.....J w ZeDc:r­u.. I O(f)

w OuJ-Li:

EME«;q 'N

CFP-12 HORIZONTAL

PANELS

FASTENERS TYP. (BY INSTALLER)

ATTACH TRIM W/BONDING TAPE

(BY INSTALLER)

LOCALIZED MEMBRANE

(BY OTHERS)

PREFINISHED JAMB TRIM ---------1 "'----------"-L.------"-''---.....>.....fi::t---....>o....L_.p......'''-_~_.:>....L..------:>.....L.-~>-.L...-~o.-L..-~-L..-~...L_~

(BY INSTALLER)

WINDOW/DOOR SYSTEM

(BY OTHERS)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 38: SUBSTITUTION CSI Form 1.5C REQUEST

",restone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • Window Head Detail 12 • H8.1 WALL ASSEMBLY TYPE 1

OVERALL WALL ASSEMBLY

INTERIOR DRYWALL (BY OTHERS)

t---..--+-_VAPOR BARRIER "OPTIONAL" (BY OTHERS)

STUD WALL 1--7'--+t-,.-~+--- (BY OTHERS)

INSULATION --'------tt--+--- R-VALUE TO CODE

(BY OTHERS)

'---------LOCALIlED MEMBRANE (BY OTHERS)

SEAL or TAPE EDGES CONTINUOUS AND ALL

_------"'o.,o::::------t'-tf-~t__- PENETRATIONS PER MANUF. RECOMMENDATIONS (BY INSTALLER)

EXTERIOR ~-...------~:..-.....,....::....,--,.j~-+-- SHEATHING

(BY OTHERS)

WATER-RESISTIVE ~~~t__-----:~---t__----'it-,....,..,.---+-- BARRIER

(BY OTHERS)

FACE OF PANEL _~ TO SHT'G

.813 21.0mm

CFP-12 HORllONTAL -l

1 PANELS

PREFINISHED FLASHING---" (BY OTHERS)

CONTINUOUS 'l'SHAPE

(BY INSTALLER)

FASTENERS TYP. (BY INSTALLER)

WATER-RESISTIVE BARRIER ----tt------r,.

(BY OTHERS)

BUTYL I HOTMELT SEALANT

(FACTORY OR FIELD APPLIED)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 To// Free (800) 426-7737 Local (763) 576-9595 Fox (763) 576-9596

Page 39: SUBSTITUTION CSI Form 1.5C REQUEST

r--:>'-rf:-,-----,,-+---(BY OTHERS)

'---------LOCALIZED MEMBRANE

WINDOW/DOOR 1--- SYSTEM

(BY OTHERS)

------.::::...-=:::--------ftt~-+--PENETRATIONS

'\.~I+----+--------+---tt--'---+--

~~"""""::".../::--~:""------I----1rt---:---+-BARRIER

..,4-~,L--:-~~-----7""-I------:::::"'~--r----l------ttr'---t-----11

'Z'GIRT --.

FLASHING---"

-----ft----~____,"""""

WATER-RESISTIVE -----+t-----b"~-;---T-~---T- .........~

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • Window Head Detail 12 • HS.2 WALL ASSEMBLY lYPE 2

BARRIER (BY OTHERS)

CFP-12 HORIZONTAL

PANELS

1/8" x1" CONT NON CURRING

BUlYL TAPE (BY INSTALLER)

CONTINUOUS

(BY INSTALLER)

FASTENERS lYP. (BY INSTALLER)

BUlYL / HOTMElT SEALANT

(FACTORY OR FIELD APPLIED)

PREFINISHED

(BY OTHERS)

OVERALL WALL ASSEMBLY

FACE OF PANEL I

TO SHT'G I .813 I 1 .500 MIN AIR SPACE

21.0 mm I I 12.7 mm I EXTERIOR SHEATHING

(BY OTHERS)

STUD WALL

INSULATION R-VALUETO CODE (BY OTHERS)

WATER-RESISTIVE

(BY OTHERS)

VAPOR BARRIER "OPTIONAL" 1---+- (BY OTHERS)

INTERIOR DRYWALL (BY OTHERS)

SEAL or TAPE EDGES CONTINUOUS AND ALL

PER MANUF. RECOMMENDATIONS (BY INSTALLER)

(BY OTHERS)

t!S.2) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 40: SUBSTITUTION CSI Form 1.5C REQUEST

Tlrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • Window Sill Detail 12 · H9.1 WALL ASSEMBLY TYPE 1

INTERIOR DRYWALL -+--- (BY OTHERS)

VAPOR BARRIER 11-4-"""-+-- "OPTIONAL"

(BY OTHERS)

INSULATION --+----\l'r--....-+-- R-VALUE TO CODE

(BY OTHERS)

...-4----+-~H--~-- STUD WALL (BY OTHERS)

WINDOWIDOOR 11------ SYSTEM

(BY OTHERS)

EXTERIOR ~--+-----~~----411--,,-,---+--- SHEATHING

(BY OTHERS)

WATER-RESISTIVE ~,Ljt-~I------:;:>"""'------I-----tf-o.,...--+-- BARRIER

(BY OTHERS)

.813 21.0 mm

CFP-12 HORIZONTAL -----II

PANELS

ATIACHMENT REVIT

SILL TRM ----,.

SILL TRIM CLIP (BY SILL TRIM

INSTALLER)

FASTENERS TYP. ---~IfL-----t:lI~~ (BY INSTALLER)

FACE OF PANEL TO SHT'G --;------1

OVERALL WALL ASSEMBLY

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 41: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 · Window Sill Detail 12 · H9.2 WALL ASSEMBLY TYPE 2

INTERIOR DRYWALL (BY OTHERS)

VAPOR BARRIER ~ .----+-- ·OPTIONAL"

(BY OTHERS)

~--4f-~+--- STUD WALL (BY OTHERS)

WINDOW/DOOR ----- SYSTEM

(BY OTHERS)

EXTERIOR ~ """,,--~------l...------I1t---'-"----,+-- SHEATHING

(BY OTHERS)

WATER-RESISTIVE ~7'tt-~-----::7"<C:..-----r---'tt--'---+-- BARRIER

(BY OTHERS)

INSULATION --r~f-r7""'*:--'<-~-----".-~------:-~-'--+-- R-VALUE TO CODE

(BY OTHERS)

SILL TRM ------,.

CFP-12 HORIZONTAL -----II

PANELS

I .813 .500 MIN AIR SPACE

21.0mm 12.7mm

ATIACHMENT REVIT

SILL TRIM CLIP (BY SILL TRIM

INSTALLER)

FACE OF PANEL TO SHT'G ---i----------1

OVERALL WALL ASSEMBLY

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 42: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series WALL ASSEMBLY TYPE 1

CFP·12 • Vertical Transitions 12 • H10.1

1/8" x1" NON CURRING

BUTYL TAPE (BY INSTALLER)

4.00" MIN LAP

OVERLAP SEAM JOINT CFp· HORIZONTAL PANELS· OPTION 'F'

(H10.1 )

NOTCH BACK FASTENING FLANGE AND HOOK FOR OVERLAP CLEARANCE (BY INSTALLER)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (BOO) 426-1131 Local (163) 516-9595 Fax (163) 516-9596

Page 43: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • Vertical Transitions 12 · H10.2 WALL ASSEMBLY TYPE 1

5.000" 127.0mm

5" FORMED TRANSITION STRIP wi REVEAL CFP· HORIZONTAL PANELS· STD. DETAIL

3.000" 76.2mm

3" FORMED TRANSITION STRIP wi SEAL JOINT CFP· HORIZONTAL PANELS· OPTION IAI

(H10.2)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 44: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • Vertical Transitions 12 • H10.3 WALL ASSEMBLY TYPE 1

511 FORMED TRANSITION STRIP wi FLAT FACE CFP· HORIZONTAL PANELS· OPTION IBI

2.000" I 1.000" I 2.000" 50.8mm I 25.4mm I 50.8mm

5.000" 127.0mm

511 EXTRUDED TRANSITION STRIP wi REVEAL CFp· HORIZONTAL PANELS· OPTION ICI

(H10.3) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 45: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1-800-426-7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 · Vertical Transitions 12· H10.4 WALL ASSEMBLY TYPE 1

1.500" 1.625" 1 1.500" 38.1mm 115.9mm' 38.1mm

3.625" 92.1mm

3.5/8" EXTRUDED TRANSITION STRIP wI REVEAL CFp· HORIZONTAL PANELS· OPTION 101

I. 5.000" 127.0mm

5" EXTRUDED TRANSITION STRIP wI FLAT FACE CFP • HORIZONTAL PANELS· OPTION lEI

(H10.4) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fox (763) 576-9596

Page 46: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • PANEL SPLICE 12 • HB.1

CFP·12 HORIZONTAL PANELS

TYPICAL PANEL I PANEL OVERLAP OTHER SPLICE OPTIONS AVAILABLE

NOTE: WHEN LAPPING PANEL 'C' OVER 'A' THE TOP FASTENER FLANGE AND BOnOM HOOK FEATURE MUST BE NOTCHED BACK TO CLEAR PANEL "A".

ALIGNED JOINTS OR STAGGERED JOINTS ARE APPLICABLE.

FURRING OR GIRT .......""""t~~+-----=---++---7"'t------------ "AS REQ'D" BY CODE

----­ WALL ASSEMBLY

~~t---+------ EXTERIOR SHEATHING

WATER RESISTIVE BARRIER

UPPER PANEL

NOTCH BACK OVERLAP PANEL TOP AND BODOM

---+--="';:-=:~-.;::-------+-----+-8---- NON-CURRING BUTYL SEAL

LOWER LEFT PANEL

LOWER RIGHT PANEL

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 47: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1-800-426-7737 www.firestonemetal.com

Delta Series CFP·12 • WDW OPENING 12 • HA.1

CFP-12 HORIZONTAL ----­

PANELS

TYPICAL WINDOW OPENING APPLICATION SEALANTS NOT SHOWN FOR CLARIIY

FURRING OR GIRT .........~~~---------:~------- liAS REO'D" BY CODE

1-------- METAL STUD

1>1----- EXTERIOR SHEATHING

1--ff11------ WATER RESISTIVE BARRIER

.'l",*~-----3o,..,..---- LOCALIZED FLEXIBLE MEMBRANE

"#----=---- METAL FLASHING

J--II--+------------- JAMB TRIM

iH'f+--+--+------------ FOAM CLOSURE STRIP

1--+------------- LOCALIZED FLEXIBLE MEMBRANE

........----­ METAL STUD

/----""-<::--:::0...::-­ METAL SILL FLASHING

IIII-I-+HI--­ LOCALIZED FLEXIBLE MEMBRANE

HH--- WATER RESISTIVE BARRIER

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 To/! Free (BOO) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 48: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1-800-426-7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12· PENETRATION 12· HA.2

TYPICAL BEAM PENETRATION APPLICATION SEALANTS NOT SHOWN FOR CLARITY DESIGN PROPER CLEARANCES TO ACCOMMODATE MOVEMENTS

FURRING OR GIRT .........~~~~-----=--------- "AS REQ'D" BY CODE

1-------- METAL STUD

1>1--:--"-----:--- EXTERIOR SHEATHING

")++~----300,~"---'----- LOCALIZED FLEXIBLE MEMBRANE

~------ METAL FLASHING

~--II--------+- AnACHMENT FLANGE

-"..._- STRUCTURAL MEMBER

K------- CLOSURE PLATE

..-1---+------ WET SEAL CUT OUT PERIMETER

,---~ LOCALIZED FLEXIBLE MEMBRANE

LMETALSTUD

-++--- EXTERIOR SHEATHINGCFP -12 HORIZONTAL PANELS

WATER RESISTIVE BARRIER

Copyright 2011© FIRESTONE METAL PRODUCTS

7007 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 49: SUBSTITUTION CSI Form 1.5C REQUEST

",restone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP-12 PANEL INDEX 12 - YO CONCEALED FASTENED PANELS

o BASE DETAILS

• HORIZONTAL JOINT DETAIL

• PARAPET ROOF DETAIL

• INSIDE CORNER DETAIL

• OUTSIDE CORNER DETAIL o SOFFIT DETAIL

• WINDOW JAMB DETAIL o WINDOW HEAD DETAIL o WINDOW SILL DETAIL

G> TRANSITION OPTIONS

VERTICAL PANELS

REFERENCE SHEETS

VO.1 - PANEL PROFILE INFORMATION

VA.1 - WINDOW OPENING ISOMETRIC

VA.2 - PENETRATION ISOMETRIC

VB.1 - PANEL I PANEL OVERLAP SPLICE

EACH DETAIL CONSISTS OF TWO DIFFERENT WALL CAVITY ASSEMBLIES; INSULATED AND NON-INSULATED.

IE: DETAIL CD ON THE ELEVATION WILL BE REPRESENTED BY TWO SHEETS 1.1 AND 1.2 ILLUSTRATING EACH RESPECTIVE WALL ASSEMBLY.

WALL TYPE 1&2 WALL ASSEMBLY DISSEMINATES GENERAL, BEST PRACTICE, RECOMMENDATION FOR USE OF AIR I VAPOR BARRIERS WITHIN U.S. DEPT. OF ENERGY CLIMATE ZONES

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fox (763) 576-9596

Page 50: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 10....-_1_-_80_0_-_4_2_6_-7_7_3_7 w_w_w_.f_ir_e_s_to_n_e_rn_e_t_a_l._c_o_rn_......1

METAL PRODUCTS

Delta Series CFP·12 • PROFILE 12 • YO.1

ITEM NUMBER: CFP-12 NET COVERAGE: 1211 (1' 0'1) MAXIMUM LENGTH: (40 feet)

'-------- 12.000 (NET COVERAGE-j

r4,000i 8.000~

6 -.-l -,.813

MATERIAL OPTIONS COIL· COATED STEEL COIL - COATED ALUMINUM ANODIZED ALUMINUM

FABRICATION OPTIONS STEEL: 18, 20, 22, 24 GAUGE ALUMINUM: .032" - .040"

FINISH OPTIONS PAINTING "COIL COATED"

HYLAR 5000 I KYNAR 500, MODIFIED POLYESTERS, AND OTHER CUSTOM OR EXOTIC FINISHES.

ANODIZING CLEAR, BRONZES, AND VARIOUS OTHER COLORS COIL ANODIZED FOR COLOR CONSISTENCY.

1. HEAVIER GAUGES MINIMIZE "OIL CANNING".NOTES: 2. OIL CANNING IS NOT ACAUSE FOR REJECTION. 3. AN EXTENSIZE SELECTION OF ASSOCIATED PANEL FLASHING AND TRIMS ARE AVAILABLE. 4. CONTACT FSMP FOR UP TO DATE TECHINCAL INFORMATION AND MATERIAL LIMITATIONS. 5. ALL SYSTEMS WITH TESTING MUST BE INSTALLED IN ACCORDANCE WITH THE ASSEMBLY AS TESTED.

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 51: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1-800-426-7737 www.firestonemetal.com

Delta Series CFP·12 • BASE DETAIL 12· V1.1 WALL ASSEMBLY TYPE 1

FACE OF PANEL

OVERALL WALL ASSEMBLY

TO SHT'G .813 21.0mm

INTERIOR DRYWALL (BY OTHERS)

VAPOR BARRIER "OPTIONAL" 11---+-- (BY OTHERS)

<J

INSULATION -""""-""""':;---d'---t-- R-VALUE TO CODE

(BY OTHERS)

.d

CSNCRETE

SEAL or TAPE EDGES CONTINUOUS AND ALL

r~r-rH-T------""":'-----+---->nI--'---+-- PENETRATIONS PER MANUF. RECOMMENDATIONS (BY INSTALLER)

EXTERIOR SHEATHING /-7K'------....::.....;:---t-::>.G.....tI--'-,..-j-- (BY OTHERS)

STUD WALL --+-----'4+--'---,-+--- (BY OTHERS)

.d WEEP TUBE

. &BAFFLE (BY INSTALLER). PRECAST

SEALANT " (BY INSTALLER) .""

1/8" X 1" NON CURRING -------.....­

BUTYL TAPE (BY INSTALLER)

PRE FINISHED BASE FLASHING ----I'

(BY INSTALLER)

CONTINUOUS HAT CHANNEL ----I-----+-----..

(BY INSTALLER)

FASTENERS TYP. (BY INSTALLER)

WATER-RESISTIVE BARRIER ----+----+----1

(BY OTHERS)

CFP -12 VERTICAL PANELS ----I

IMPROVE ENERGY EFFICIENCY WITH PROPER COMPONENT WALL ASSEMBLIES IN MOST REGIONS, EXTERIOR WALLS HAVING INSULATION INSIDE THE STUD WALL CAVITY SHOULD USE AVAPOR-PERMEABLE MEMBRANE APPLIED ON THE EXTERIOR SIDE OF THE WALL. A VAPOR-PERMEABLE MEMBRANE ALLOWS THE WALL CAVITY TO BREATH AND DRY POTENTIAL MOISTURE CAUSED FROM VAPOR PRESSURE. IN COLDER CLIMATES ANON-PERMEABLE VAPOR BARRIER MUST BE INSTALLED ON THE INTERIOR SIDE OF THE WALL ASSEMBLY TO MINIMIZE OUTWARD VAPOR PRESSURE CAUSED BY HEATED AND HUMIDIFIED INTERIOR ENVIRONMENTS DURING THE COLD SEASON.

2006 INTERNATIONAL BUILDING CODE -1403.2 WEATHER PROTECTION: EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH AWEATHER-RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTIVE BARRIER ON THE SIDE OF THE WALL BEHIND THE EXTERIOR VANEER. PROVIDE MEANS OF DRAINING WATER THAT ENTERS BETWEEN THE EXTERIOR VANEER AND THE WATER-RESISTANT BARRIER.

(V1.1) Copyright 201l© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fox (763) 576-9596

Page 52: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP-12 - BASE DETAIL 12-Y1.1A WALL ASSEMBLY TYPE 1

FACE OF PANEL TO SHT'G

OVERALL WALL ASSEMBLY

~ 21.0 mm I

WATER-RESISTIVE -----t---+-----~I/ BARRIER SEAL or TAPE EDGES

(BY OTHERS) CONTINUOUS AND ALL

CFP -12 VERTICAL (~r-rH-T----~::"""---+-----Tit-'-'-'-+-- PENETRATIONS PER PANELS ----I MANUF. RECOMMENDATIONS

(BY INSTALLER)

CONTINUOUS EXTERIOR SHEATHING /*-----.::.....::--+--::-"--tt-~+-- (BY OTHERS)HATCHANNEL----~-~~

(BY INSTALLER)

FASTENERS TYP. --+----lH-~-+-- STUD WALL

(BY OTHERS) (BY INSTALLER) ----...

INSULATION

1/8" x 1" NON CURRING BUTYL TAPE ------....

~-"'T""7"'"----rf---+-- R-VALUE TO CODE (BY OTHERS)

(BY INSTALLER)

INTERIOR DRYWALL (BY OTHERS)

VAPOR BARRIER "OPTIONAL" ,.......--,.-+-- (BY OTHERS)

PRE FINISHED BASE FLASHING

(BY INSTALLER)

<J

SEALANT (BY INSTALLER)

WEEP TUBE . & BAFFLE

L1 L1

CSNCRETE

.PRECAST (BY INSTALLER) /I

IMPROVE ENERGY EFFICIENCY WITH PROPER COMPONENT WALL ASSEMBLIES IN MOST REGIONS, EXTERIOR WALLS HAVING INSULATION INSIDE THE STUD WALL CAVITY SHOULD USE AVAPOR-PERMEABLE MEMBRANE APPLIED ON THE EXTERIOR SIDE OF THE WALL. AVAPOR-PERMEABLE MEMBRANE ALLOWS THE WALL CAVITY TO BREATH AND DRY POTENTIAL MOISTURE CAUSED FROM VAPOR PRESSURE. IN COLDER CLIMATES A NON-PERMEABLE VAPOR BARRIER MUST BE INSTALLED ON THE INTERIOR SIDE OF THE WALL ASSEMBLY TO MINIMIZE OUTWARD VAPOR PRESSURE CAUSED BY HEATED AND HUMIDIFIED INTERIOR ENVIRONMENTS DURING THE COLD SEASON.

2006 INTERNATIONAL BUILDING CODE -1403.2 WEATHER PROTECTION: EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND CONSTRUCTED TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTIVE BARRIER ON THE SIDE OF THE WALL BEHIND THE EXTERIOR VANEER. PROVIDE MEANS OF DRAINING WATER THAT ENTERS BETWEEN THE EXTERIOR VANEER AND THE WATER-RESISTANT BARRIER.

(\11.1) OPTION A Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 53: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP-12 - BASE DETAIL 12-Y1.2 WALL ASSEMBLY TYPE 2

OVERALL WALL ASSEMBLY

FACE OF PANEL I

INTERIOR DRYWALL (BY OTHERS)

VAPOR BARRIER \I~----.-,I- "OPTIONAL"

(BY OTHERS)

:---\1-----'---1--_ STUD WALL (BY OTHERS)

SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER

'.----RJ.--4-- MANUF. RECOMMENDATIONS

(BY INSTALLER)

/\

CONC~TE·

<J

INSULATION ----,~tr-r7'lt-1L.-.,f----~:----+---fHI-----,----+-- R-VALUE TO CODE

(BY OTHERS)

WEEP TUBE & BAFFLE

. (BY INSTALLER) I I

I .500 MIN AIR SPAtEI 12.7mm

1 ~~~~~~~ /?'H---l----------:::,....=~____lf.,......,.......-+-- EXTERIOR SHEATHING.r. (BY OTHERS)

PRECAST· .

.813 I

21.0 mm I

SEALANT. (BY INSTALLER) .

CONTINUOUS 'Z'GIRT

(BY INSTALLER)

LOCALIZED MEMBRANE

(BY INSTALLER)

FASTENERS TYP. (BY INSTALLER)

1/8" x1"

NON CURRING -----L-.llIl1$~ BUTYL TAPE (BY INSTALLER)

PRE FINISHED ./ BASE FLASHING ~~;;;:;:~

(BY INSTALLER) t~~~~b==~ff~~=;;;;;;;;;;;;===~~~~<J~=i

TO SHT'G

WATER-RESISTIVE BARRIER

(BY OTHERS) -------t-----+--+-~~-----r-~-I1

CFP -12 VERTICAL PANELS -----I

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka, Minnesota 55303 Toll Free (800) 426-1737 Local (763) 576-9595 Fax (763) 576-9596

Page 54: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1-800-426-7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • BASE DETAIL 12 • V1.2A WALL ASSEMBLY TYPE 2

OVERALL WALL ASSEMBLY

FACE OF PANEL I

TO SHT'G I I.813 .500 MIN AIR SPAtE SEAL or TAPE EDGES

WATER-RESISTIVE 21.0mm I I 12.7mm CONTINUOUS AND ALL BARRIER PENETRATIONS PER

(BY OTHERS) -----+---+---It--~--iI'.,....-.y ____-H.."....-,--'-\-- MANUF. RECOMMENDATIONS

CFP - 12 VERTICAL (BY INSTALLER)PANELS -----0-1

CONTINUOUS INSULATION 'Z'GIRT --::o~-b'7'7'1t-7<--t---~:-----t---flt-----:--+-- R-VALUE TO CODE

(BY INSTALLER) (BY OTHERS)

LOCALIZED MEMBRANE STUD WALL

------11----',-/- (BY OTHERS)(BY INSTALLER)

FASTENERS TYP. (BY INSTALLER) I ~~~~~~~ /"~--l----------:::""':=:=~----If.:""':"""';'-4-- EXTERIOR SHEATHING

_'It" (BY OTHERS)

1/8" X 1" NON CURRING BUTYL TAPE -----t---tIIi INTERIOR DRYWALL (BY INSTALLER) (BY OTHERS)

VAPOR BARRIER \11--"":"""""- "OPTIONAL"

(BY OTHERS)

PRE FINISHED BASE FLASHING

(BY INSTALLER) <J

WEEP TUBE CONC~TE

&BAFFLE <JPRECAST·

SEALANT . (BY INSTALLER) (BY INSTALLER) . I I

(\11.2) OPTION A Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 55: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • HORIZONTAL JOINT DETAIL 12 • V2.1 WALL ASSEMBLY TYPE 1

INTERIOR DRYWALL (BY OTHERS)

VAPOR BARRIER ·OPTIONAL"

(BY OTHERS)

STUD WALL I---tt-....;...--+-- (BY OTHERS)

INSULATION ---'--....,......'--'----'+-- R-VALUE TO CODE

(BYOTHERSj

.r+t---r-----------,.;;:-=:.:::t:,.-----1I--,--+-- EXTERIOR SHEATHING (BY OTHERS)

OVERALL WALL ASSEMBLY

SEAL or TAPE EDGES ~"7+.\----;-------;;?'':::''''''---:--~--+-- CONTINUOUS AND ALL

PENETRATIONS PER MANUF. RECOMMENDATIONS (BY INSTALLER)

.813 21.0mm

CONTINUOUS HATCHANNEL---~-~

(BY INSTALLER)

TO SHT'G FACE OF PANEL

~ z ~

a CONT ~

NONCURRING BUTYL SEALANT ---l--J

(BY INSTALLER)

FASTENERS TYP. -1------.

(BY INSTALLER)

CFP -12 VERTICAL PANELS ----0-1

CFP -12 VERTICAL PANELS ---P

WATER-RESISTIVE BARRIER -----1~-----t--_Jv

(BY OTHERS)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 56: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • TRANSITION OPTIONS 12 • V2.1A WALL ASSEMBLY TYPE 1

FORMED TRANSITION STRIP @ MOVEMENT JOINT CFP - HORIZONTAL PANELS ­ STANDARD DETAIL

.. E <:) E ~; ...­ ("")

.. E <:) E ~; ...­ ("")

.. E 8~ C!ci No.n

3-5/8" EXTRUDED TRANSITION STRIP wI REVEAL CFP • HORIZONTAL PANELS - OPTION "A"

(V2.1A) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 57: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • TRANSITION OPTIONS 12· V2.1B WALL ASSEMBLY TYPE 1

= E o E

~::: LO~

5" EXTRUDED TRANSITION STRIP wI REVEAL CFP· HORIZONTAL PANELS· OPTION "B"

= E 8~ lC!ci Nil)

- ,-­ L:::=:::;r=-+~

= E .. E 88 8~ ~~ ~~

-f­ r.==:::...:::..+~

= E 8~ C!ci Nil)

5" EXTRUDED TRANSITION STRIP wI FLAT FACE CFP· HORIZONTAL PANELS· OPTION "C"

(V2.1B) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (BOO) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 58: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1-800-426-7737 www.firestonemetal.com

Delta Series CFP·12· HORIZONTAL JOINT DETAIL WALL ASSEMBLY lYPE 2

.813 I. .500 MIN AIR SPACE 21.0mm 12.7mm

FACE OF PANEL TO SHT'G

OVERALL WALL ASSEMBLY

Copyright 2011© FIRESTONE METAL PRODUCTS

12 • V2.2

1001 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 59: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1-800-426-7737 www..firestonemetal.com

Delta Series CFP·12 • TRANSITION OPTIONS 12· V2.2A WALL ASSEMBLY TYPE 2

<J

FORMED TRANSITION STRIP @ MOVEMENT JOINT CFP ~ HORIZONTAL PANELS· STANDARD DETAIL

FLR SLAB

o E o E o coe-.ig

.. E o E ~;;j ..-­ en

3.5/8" EXTRUDED TRANSITION STRIP wI REVEAL CFP • HORIZONTAL PANELS· OPTION "A"

(V2.2A) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 60: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • TRANSITION OPTIONS 12· V2.2B WALL ASSEMBLY TYPE 2

5" EX·rRUDED TRANSITION S·rRIP wI REVEAL CFP· HORIZONTAL PANELS· OPTION "B"

= E o E

~~ LO~

5" EXTRUDED TRANSrnON STRIP wI FLAT FACE CFp· HORIZONTAL PANELS· OPTION "C"

(V2.2B) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka, Minnesota 55303 Toll Free (BOO) 426-7737 Local (763) 576-9595 Fox (763) 576-9596

Page 61: SUBSTITUTION CSI Form 1.5C REQUEST

",restone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • PARAPET ROOF DETAIL 12 • V3.1 WALL ASSEMBLY TYPE 2

ROOFING MEMBRANE (BY INSTALLER)

FIRE RATED PLYWOOD :--­ (BY OTHERS) I I VAPOR BARRIER "OPTIONAL"

Ho+t-Ht-- (BY OTHERS)

_--1'+-- WOOD BLOCKING (BY OTHERS)

.---If-H-HHI-- STUD WALL (BY OTHERS)

M---+--------I---tH+++-lf--- EXTERIOR SHEATHING (BY OTHERS)

.------ LOCALIZED MEMBRANE (BY INSTALLER)

SEAL or TAPE EDGES ~"7'H-----"-,,..-:-:::~,....,..,,,..,.--:-==:-:":"-:-----it-H-++-I!'--- CONTINUOUS AND ALL

SLOT PANEL AT THIS PENETRATIONS PER FASTENER TO ALLOW MANUF. RECOMMENDATIONS

D~~/S FOR THERMAL EXPANSION (BY INSTALLER) SEAL WIBUTYL TAPE BY INSTALLER)

.813 21.0mm

'z' FLASHING (BY INSTALLER)

PRE FINISHED COPING

(BY INSTALLER)

1/8" x1" CONT NON CURRING ---"111111

BUTYL TAPE (BY INSTALLER)

TO SHT'G

CONTINUOUS ------l-J-~~~ HAT CHANNEL

(BY INSTALLER)

WATER-RESISTIVE -----8---...+------i/

BARRIER (BY OTHERS)

FACE OF PANEL

LOCALIZED MEMBRANE ---.......-II-----...dIIl

(BY INSTALLER)

CFP -12 VERTICAL PANELS ----0

OVERALL WALL ASSEMBLY

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 62: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • PARAPET ROOF DETAIL 12 • V3.2 WALL ASSEMBLY TYPE 2

PRE FINISHED COPING -------II

(BY INSTALLER)

1/8" X 1" CONT NON CURRING

BUTYL TAPE (BY INSTALLER)

SLOT PANEL AT THIS FASTENER TO ALLOW

FOR THERMAL EXPANSION SEAL W/BUTYL TAPE

(BY INSTALLER)

CFP - 12 VERTICAL -II

PANELS

ROOFING MEMBRANE (BY INSTALLER)

LOCALIZED ~ frr.:"""'=:'::::::::=:'-:::::-=:'~=:'~=~-:.:.::.,~~~~~::;;::;=MEMBRANE ~I -

(BY INSTALLER) ..J :

~Omn1111m~ SEAL or TAPE EDGES

'z' FLASHING (BY INSTALLER)

CONTINUOUS AND ALL ~"7'I+-----------tl-+H-H'-- PENETRATIONS PER

MANUF. ,--~~-- LOCALIZED

RECOMMENDATIONSMEMBRANE (BY INSTALLER)(BY INSTALLER)

EXTERIOR SHEATHING 7"11:--,....---CO-N-T-IN-U-O-US-----:--,+++-++-f-- (BY OTHERS)

..........",..---I¥-:~I---+- HAT CHANNEL (BY INSTALLER) f---tt-I-t+1I-+-- STUD WALL

WATER-RESISTIVE -----t-----1i--+>-<-+-"<---:,.e----.>..,.........,.*'!/

BARRIER (BY OTHERS)

.813 .500 MIN AIR SP~CEI 21.0mm' I 12.7mm

FACE OF PANEL TO SHT'G

OVERALL WALL ASSEMBLY

(BY OTHERS)

RATED PLYWOOD (BY OTHERS)

Ho-H++-- VAPOR BARRIER "OPTIONAL"

(BY OTHERS)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 63: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www;fi restonemeta I.com METAL PRODUCTS

Delta Series CFP·12 • INSIDE CORNER DETAIL 12 • V4.1 WALL ASSEMBLY TYPE 1

INTERIOR DRYWALL

PRE FINISHED (BY OTHERS)INSIDE CORNER ----o-ll

(BY INSTALLER) o E INSULATIONOE Ocn ------\f-:-...,....,-.+-- R-VALUE TO CODE~:8 (BY OTHERS)

EXTERIOR SHEATHING

(BY OTHERS)CONTINUOUS HAT CHANNEL ----tt---+__

(BY INSTALLER) ~--+-'--'--+-_ STUD WALL (BY OTHERS)

WATER-RESISTIVE BARRIER ----It----I"'--------t++_~

(BY OTHERS)

CFP - 12 VERTICAL PANELS -----ll

.813 I 21.0mm I

FACE OF PANEL ----+------.jI ITO SHT'G OVERALL WALL ASSEMBLY

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 64: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • INSIDE CORNER OPTION 12 • V4.1A WALL ASSEMBLY TYPE 1

2.375" MIN 60.3mm

ALUM EXTRUSION

ALUM EXTRUSION ~

1/8" x 1" CONT NON CURRING

~"'f+-- BUTYL TAPE (BY INSTALLER)

,/

1/8" X 1" CaNT NON CURRING

,--BUTYL TAPE (BY INSTALLER)

EXTRUDED CAPTURED 90° CORNER wI REVEAL CFP· HORIZONTAL PANELS· OPTION 'A'

(V4.1A) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 65: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series WALL ASSEMBLY TYPE 1

CFP·12 • INSIDE CORNER OPTION

ALUM EXTRUSION

ALUM EXTRUSION

ExrRUDED CAPTURED 90° CORNER wI REVEAL CFP· HORIZONTAL PANELS· OPTION IBI

(V4.1B)

12· V4.1B

/ 1/8" x1" CONT NON CURRING BUTYL TAPE (BY INSTALLER)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-1137 Local (763) 576-9595 Fox (763) 576-9596

Page 66: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • INSIDE CORNER DETAIL 12 • V4.2 WALL ASSEMBLY TYPE 2

____--­ STUD WALL (BY OTHERS)

WATER-RESISTIVE 1'1I .....~----- BARRIER

(BY OTHERS)

INSULATION -.,~~'it-r--~:---- R-VALUE TO CODE

(BY OTHERS)

EXTERIOR ~--tT'-~~~~:"'lp'\.~tr--~=-""---- SHEATHING

(BY OTHERS)

.813 I .500 MIN AIR SPACE 21.0mm 1 12.7mm

~~~:I+--r-------::::""":::'-- INSULATION R-VALUE TO CODE (BY OTHERS)

CONTINUOUS 'l' GIRT ----it----ff­

(BY INSTALLER)

1/8" x1" CONT NON CURRING __----,111

BUTYL TAPE (BY INSTALLER)

PRE FINISHED INSIDE CORNER ----II

(BY INSTALLER)

CFP - 12 VERTICAL PANELS ----1-1-----­

= E 8!3Lqaj C") co

FACE OF PANEL TO SHT'G

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 67: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • INSIDE CORNER DETAIL 12· V4.2A WALL ASSEMBLY TYPE 2

_--­ STUD WALL (BY OTHERS)

WATER-RESISTIVE J'II ....~'------- BARRIER

(BY OTHERS)

INSULATION -->XO'---lf>'~r--7"''--------7''~- R-VALUE TO CODE

(BY OTHERS)

EXTERIOR ~--j-,.L-~-+-~~ ...I~ ""'~----::""=-""'---- SHEATHING

(BY OTHERS)

CONTINUOUS 'z' GIRT ---it------tI- '-"--""",-----,,------"----->-----'3J'

(BY INSTALLER)

CFP - 12 VERTICAL PANELS

ALUM EXTRUSION

(V4.2A) Copyright 2011© FIRESTONE METAL PRODUCTS

tOOl Lund Boulevard. Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fox (763) 576-9596

Page 68: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series WALL ASSEMBLY TYPE 2

CFP·12· INSIDE CORNER OPTION 12· V4.2B

ALUM EXTRUSION

ALUM EXTRUSION

EXTRUDED CAPTURED 90° CORNER wI REVEAL CFP • HORIZONTAL PANELS· OPTION IBI

(V4.2B) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevord. Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 69: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1-800-426-7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12· OUTSIDE CORNER DETAIL 12· V5.1 WALL ASSEMBLY TYPE 1 OVERALL WALL ASSEMBLY

.FACE OF PANEL---f.i--...] TO SHT'G .813

21.0mm

I

I I I I I I I I I

WATER-RESISTIVE I BARRIER ------*----I-r-----tO++~

(BY OTHERS}

CFP -12 VERTICAL PANELS ------JI

1/8" x1" CONT NON CURRING

BUTYL TAPE (BY INSTALLER)

CONTINUOUS HATCHANNEL----*--~~--

(BY INSTALLER)

PRE FINISHED OUTSIDE CORNER ----II

(BY INSTALLER)

~,..........,..,--+-

~T------::::"'"""",------ftII.----:--+----

------'d-~--+----

c:::z=:::::tt-....-+---­(BY OTHERS}

I----INTERIOR DRYWALL (BY OTHERS}

STUD WALL (BY OTHERS}

EXTERIOR SHEATHING

(BY OTHERS}

INSULATION R-VALUE TO CODE (BY OTHERS}

VAPOR BARRIER "OPTIONAL"

1/8" x1" CONT 4.750" NON CURRING 120.7mm BUTYL TAPE

(BY INSTALLER)

CFP -12 VERTICAL PANELS

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 70: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • OUTSIDE CORNER OPTION 12· V5.1A WALL ASSEMBLY TYPE 1

COMPRESSIVE GASKET

(BY INSTALLER)

ALUM EXTRUSION

ALUM EXTRUSION

I. 4.000" 101.6mm

DELTA SERIES PANEL

EXTRUDED CAPTURED 900 CORNER wi FLAT FACE OPTION CFP • HORIZONTAL PANELS· OP"nON IAI

(V5.1A) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll free (800) 426-7737 Local (763) 576-9595 fox (763) 576-9596

Page 71: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1-800-426-7737 www.firestonemetal.com

Delta Series CFP·12· OUTSIDE CORNER OPTION WALL ASSEMBLY TYPE 1

DELTA SERIES PANEL ---II

COMPRESSIVE GASKET

(BY INSTALLER)

ALUM EXTRUSION

ALUM EXTRUSION

12· V5.1B

I, 2.000" 50.8mm

EXTRUDED CAPTURED 900 CORNER wi REVEAL OPTION CFP· HORIZONTAL PANELS· OPTION IBI

(V5.1B) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 72: SUBSTITUTION CSI Form 1.5C REQUEST

"Irestone 1-800-426-7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12· OUTSIDE CORNER DETAIL 12· V5.2 WALL ASSEMBLY TYPE 2

WATER-RESISTIVE ~------"'7"""':="':::::--"ffi-'--r--­

EXTERIOR SHEATHING

(BY OTHERS) BARRIER --ft--tt---joL-~,L-~"---o1K..

(BY OTHERS) INSULATION

~-~~f-----~..,.....------+-111-------1-- R-VALUE TO CODE (BY OTHERS)

STUD WALL -*---+.--F----¥--~-l~~­(BY OTHERS)

I~--,-t--- VAPOR BARRIER "OPTIONAL" (BY OTHERS)

CFP - 12 VERTICAL INTERIOR DRYWALL PANELS (BY OTHERS)

FASTENERS TYP. (BY INSTALLER)

CONTINUOUS 'Z'GIRT (BY INSTALLER)

PRE FINISHED INSIDE CORNER

(BY INSTALLER)

6.500" 165.1mm

1/8" x 1" CONT NON CURRING BUTYL TAPE (BY INSTALLER)

CFP -12 VERTICAL PANELS

(\15.2) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 73: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12· OUTSIDE CORNER DETAIL 12· V5.2A WALL ASSEMBLY TYPE 2

COMPRESSIVE GASKET

ALUM EXTRUSION

ALUM EXTRUSION

-------­

CONTINUOUS 'l' GIRT (BY INSTALLER)

I. DELTA SERIES PANEL4.000" 101.6mm

EXTRUDED CAPTURED 90° CORNER wI FLAT FACE OPTION CFp· HORIZONTAL PANELS· OPTION 'A'

(V5.2A) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fox (763) 576-9596

Page 74: SUBSTITUTION CSI Form 1.5C REQUEST

",restone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12· OUTSIDE CORNER DETAIL 12· V5.2B WALL ASSEMBLY TYPE 2

CONTINUOUS 'Z' GIRT (BY INSTALLER)

2.000" 50.8mm

I.

1/8" x 1" CONT NONCURRING

BUTYL TAPE (BY INSTALLER)

COMPRESSIVE -~:I 111F=====ll11

GASKET

ALUM EXTRUSION

ALUM EXTRUSION

DELTA SERIES PANEL ---.-11

EXTRUDED CAPTURED 90° CORNER wi REVEAL OPTION CFP· HORIZONTAL PANELS· OPTION 'B'

(V5.2B) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 75: SUBSTITUTION CSI Form 1.5C REQUEST

",restone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • SOFFIT DETAIL WALL ASSEMBLY TYPE 1

CFP -12 VERTICAL PANELS----I

WATER-RESISTIVE-----f------i---tv BARRIER

(BY OTHERS)

SEAL or TAPE EDGES CONTINUOUS AND ALL

PENETRATIONS PER MANUF.

RECOMMENDATIONS-- ­(BY INSTALLER)

12 • V6.1

VAPOR BARRIER "OPTIONAL"

(BY OTHERS)

INTERIOR DRYWALL "-f--- (BY OTHERS)

STUD WALL 1-----\1...,...--....,-4--- (BY OTHERS)

INSULATION ~~~I--'--+-- R-VALUE TO CODE

(BY OTHERS)

FASTENERSTYP. __~

(BY INSTALLER)

1/8" x 1" CONT NON CURRING ~--+--ilrnIIID!S

BUTYL TAPE (BY INSTALLER)

~ I:C ~1/8" x 1" CONT W

NON CURRING 00

~ BUTYL TAPE ....J ....J(BY INSTALLER) ~ ....J ....J

~ W >a

PRE FINISHED BASE FLASHING

(BY INSTALLER) ------;~;:::::::::;;:=J1L:==s---------------T----..,..-...L---+-..J...1

WEEP HOLE --~ ....JCFP -12 EXTERIOR W z~VERTICAL PANELS SHEATHING ~i-

PRE FINISHED---------J (BY OTHERS) u..::I: 000SOFFIT FLASHING w O

(,,)1­(BY INSTALLER) ~

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fox (763) 576-9596

Page 76: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • SOFFIT DETAIL 12 • V6.2 OVERALL WALL ASSEMBLYWALL ASSEMBLY TYPE 2

FACE OF PANEL ------1-0------------11

TO SHT'G .1 .813 .500 MIN AIR SPACE1 I

21.0mm I I 12.7 mm I STUD WALL

,----+f---+-- (BY OTHERS)

INSULATION / ~~~""t"-T-----l------::::o--"""""--T+t"....,........:.+-- R-VALUE TO CODE

(BY OTHERS)

INTERIOR DRYWALL (BY OTHERS)

VAPOR BARRIERCFP -12 VERTICAL PANELS ---I "OPTIONAL"

(BY OTHERS)

WATER-RESISTIVE BARRIER -----1I---f------+<,----~-~-I~/

(BY OTHERS)

SEAL or TAPE EDGES CONTINUOUS AND ALL

PENETRATIONS PER -----+----+~

MANUF. RECOMMENDATIONS

(BY INSTALLER)

LOCALIZED -------il---I------+"""*'

MEMBRANE (BY INSTALLER)

FASTENERS TYP. ----1---1--­

(BY INSTALLER)

1/8" x1" NON CURRING BUTYL TAPE (BY INSTALLER)

PRE FINISHED BASE FLASHING

(BY INSTALLER)

WEEP HOLE PRE FINISHED BASE FLASHING

(BY INSTALLER)

CFP -12 VERTICAL PANELS

EXTERIOR I

SHEATHING~ (BY OTHERS)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 77: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1-800-426-7737 www.firestonemetal.com METAL PRODUCTS

Delta Series WALL ASSEMBLY TYPE 1

CFP·12· WINDOW JAMB DETAIL 12 • V7.1

STUD WALL

LOCALIZED MEMBRANE

(BY OTHERS)

WINDOW/DOOR SYSTEM

(BY OTHERS)

PREFINISHED ~

(BY INSTALLER)

....J w ze> ~~ u..::I:

000 w O

SEALANT NON CURRING HAT CHANNEL VERTICAL PANELS u~

(BY INSTALLER)

EXTERIOR SHEATHIN

(BY OTHERS)

WATER-RESISTIVE BARRIER

(BY OTHERS)

,.----- (BY OTHERS)

INSULATION ,.---- R-VALUE TO CODE

(BY OTHERS)

VAPOR BARRIER "OPTIONAL" (BY OTHERS)

NTERIOR DRYWALL (BY OTHERS)

CFP -12CONTINUOUSBUTYL / HorMELT 1/8" x1" CONT

(Y)~ ~

JAMB TRIM ------L__"""""""~~~!ii!iiF======t========r==-.l.-N--+--J.....t

(FACTORY OR FIELD APPLIED) BUTYL ~ (BY INSTALLER)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 78: SUBSTITUTION CSI Form 1.5C REQUEST

'F,restone 1-800-426-7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • WINDOW JAMB DETAIL 12 • V7.2 WALL ASSEMBLY TYPE 2

WATER-RESISTIVE BARRIER INSULATION R-VALUE TO CODE (BY OTHERS) ----------, .-------- (BY OTHERS)

STUD WALL VAPOR BARRIER "OPTIONAL" (BY OTHERS) ---------, (BY OTHERS)

EXTERIOR SHEATHING (BY OTHERS)

INTERIOR DRYWALL (BY OTHERS)

LOCALIZED MEMBRANE

(BY OTHERS)

WINDOW/DOOR SYSTEM

(BY OTHERS)

BUTYL / HOTMELT 1/8" x1" CONT CFP -12 SEALANT NON CURRING VERTICAL PANELS

(FACTORY OR FIELD APPLIED) BUTYL TAPE (BY INSTALLER)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 79: SUBSTITUTION CSI Form 1.5C REQUEST

'Ftrestone METAL PRODUCTS

1-800-426-7737 www.firestonemetal.com

Delta Series CFP·12· WINDOW HEAD DETAIL 12 • V8.1 WALL ASSEMBLY TYPE 1

-+---INTERIOR DRYWALL (BY OTHERS)

STUD WALL (BY OTHERS)

INSULATION I--""<---++--~+---R-VALUE TO CODE

(BY OTHERS)

VAPOR BARRIER 1"--'---+--- "OPTIONAL"

~----'I (BY OTHERS)

LOCALIZED '----------MEMBRANE

(BY OTHERS)WINDOW/DOOR 1----- SYSTEM

(BY OTHERS)

EXTERIOR SHEATHING

~+---+---~o:::-----+---r-tt------t--- (BY OTHERS)

OVERALL WALL ASSEMBLY

SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF.

~..>..M+_"":""- ----'::::"":----"':""'::"----:..j~--.:+- __ RECOMMENDATIONS (BY INSTALLER)

WATER-RESISTIVE ..--..-=-_ foiI!~t-----r--------------:>"o;::--""""L::"""'----Ti-----+-----BARRI ER

(BY OTHERS)

FACEOFPANEL~~ TO SHT'G .813

21.0mm

PREFINISHED 'J' TRIM ----------1~I~~~~,

(BY INSTALLER)

WEEP HOLE ---'

CONTINUOUS HATCHANNEL---------~

(BY INSTALLER)

SEALANT (BY INSTALLER)

PREFINISHED FLASHING .....J

(BY OTHERS)

FASTENERS TYP. (BY INSTALLER)

CFP -12 ----_J VERTICAL PANELS

LOCALIZED MEMBRANE (BY INSTALLER) ------1----+---1],

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 80: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12· WINDOW HEAD DETAIL 12· V8.1A WALL ASSEMBLY TYPE 1

OVERALL WALL ASSEMBLY

.FACE OF PANEL ----s;;-­TO SHT'G .813

LOCALIZED MEMBRANE ------1-----4---"­(BY INSTALLER)

CONTINUOUS HAT CHANNEL --- ­

(BY INSTALLER)

CFP - 12 --------t-l VERTICAL PANELS

PREFINISHED

FLASHING~ (BY OTHERS)

'- -""'~~..

WIN DOWIDOOR 1--- SYSTEM

(BY OTHERS)

~f,L---+---~.,.-----+---+-I"""""""'-'+--

l~~-~~-"'--------::"'~"'""J7"'~~~--BARRIER

21.0mm

-, ~ I

~~-...l..----~~~---!.J~--'-!---

EXTERIOR SHEATHING

(BY OTHERS)

SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS (BY INSTALLER)

STUD WALL (BY OTHERS)

INSULATION ~~---'-----+--- R-VALUE TO CODE

(BY OTHERS)

WATER-RESISTIVE

(BY OTHERS)

VAPOR BARRIER r1.4-'---'l--- "OPTIONAL"

(BY OTHERS)

~--INTERIOR DRYWALL (BY OTHERS)

LOCALIZED ----------MEMBRANE

(BY OTHERS)

(\fS.1) OPTION A Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 81: SUBSTITUTION CSI Form 1.5C REQUEST

I--+-- "OPTIONAL"

~"--l-f,-----:'--+--

.--+-----'It'---+-- PENETRATIONS PER

""'----------------------- LOCALIZED MEMBRANE WINDOW/DOOR

If---- SYSTEM (BY OTHERS)

~--7":::......-----=:....::::---------tl~-t--

,{k"'~--:P--E-----.....----I1I----'"'-t--

~~~-----::>-.i:::::-~-----r---+-----4""""""--+-

MEMBRANE------~

'z' GIRT -----f--..

FASTENERS TYP. --------h

12 __----I

----I-----Jr-----f>'.<---r~---+-....o...--......,.....

FLASHING ----1ti~g~2~~~~~~~~~;;;;-~~~~(BY INSTALLER));

BUTYL TAPE ------I.

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12· WINDOW HEAD DETAIL 12 • V8.2 WALL ASSEMBLY TYPE 2

OVERALL WALL ASSEMBLY

FACE OF PANEL--t-----------I TO SHT'G

WATER-RESISTIVE BARRIER

(BY OTHERS)

CFP ­VERTICAL PANELS

CONTINUOUS

(BY INSTAlLER)

LOCALIZED

(BY INSTALLER)

(BY INSTAlLER)

1/8" x 1" NON CURRING

(BY INSTALLER)

PRE FINISHED BASE

WEEP HOLE

SEALANT (BY INSTALLER)

PREFINISHED FLASHING (BY OTHERS)

STUD WALL (BY OTHERS)

INSULATION R-VALUE TO CODE (BY OTHERS)

SEAL or TAPE EDGES CONTINUOUS AND ALL

MANUF. RECOMMENDATIONS (BY INSTAlLER)

WATER-RESISTIVE BARRIER (BY OTHERS)

VAPOR BARRIER

(BY OTHERS)

INTERIOR DRYWALL (BY OTHERS)

EXTERIOR SHEATHING (BY OTHERS)

(BY OTHERS)

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 82: SUBSTITUTION CSI Form 1.5C REQUEST

'F,restone METAL PRODUCTS

1-800-426-7737 www.firestonemetal.com

Delta Series CFP·12 • WINDOW HEAD DETAIL 12· VS.2A WALL ASSEMBLY TYPE 2

OVERALL WALL ASSEMBLY

INTERIOR DRYWALL (BY OTHERS)

VAPOR BARRIER J---+-- "OPTIONAL"

(BY OTHERS)

SEAL or TAPE EDGES CONTINUOUS AND ALL

-----t--IH------l- PENETRATIONS PER MANUF. RECOMMENDATIONS (BY INSTALLER)

WINDOWIDOOR If---- SYSTEM

(BY OTHERS)

EXTERIOR ~----7"'-::"""-~:---------+l.,.....,....---1-- SHEATHING

(BY OTHERS)

~~---3--E----------II-----"":""-+-- WATER-RESISTIVE BARRIER (BY OTHERS)

INSULATION "":--"'7't-'~+--~-;::r""'---"7--+--tf-...--+- R-VALUE TO CODE

(BY OTHERS)

STUD WALL 1-+-++------1- (BY OTHERS)

FACE OF PANEL TO SHT'G

LOCALIZED MEMBRANE--~

(BY INSTALLER)

PREFINISHED FLASHING (BY OTHERS)

CONTINUOUS 'z' GIRT ---t........

(BY INSTALLER)

1/8" X 1" NON CURRING

BUTYL TAPE ----1

(BY INSTALLER)

FASTENERS TYP. ----I-\. (BY INSTALLER)

CFP-12 __-I

VERTICAL PANELS

WATER-RESISTIVE ----I----I---+---,;~----r~--r--a" BARRIER

(BY OTHERS)

(\IS.2) OPTION A Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 83: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • WINDOW SILL DETAIL 12 • V9.1 WALL ASSEMBLY TYPE 1

EXTERIOR SHEATHING

(BY OTHERS)

INTERIOR DRYWALL --+--- (BY OTHERS)

VAPOR BARRIER "OPTIONAL" 1"-"'-'---+--­ (BY OTHERS)

I--It--,--+-- STUD WALL (BY OTHERS)

INSULATION -r--r-It----+-- R-VALUE TO CODE

(BY OTHERS)

WINDOW/DOOR 11---- SYSTEM

(BY OTHERS)

WATER-RESISTIVE ¥-JoL:A+'t------,f----~--+---"'rtI-----,-I--- BARRIER

(BY OTHERS)

SEAL or TAPE EDGES

r--.......-...=~~~~~~~~~=~.,....---.,-+-- CONTINUOUS AND ALL PENETRATIONS PER MANUF. RECOMMENDATIONS (BY INSTALLER)

SILL TRIM CLIP (BY SILL TRIM

INSTALLER)

CONTINUOUS HAT CHANNEL

(BY INSTALLER)

FASTENERS TYP. (BY INSTALLER)

CFP -12 ------I VERTICAL PANELS

SILL TRIM --........

LOCALIZED MEMBRANE (BY INSTALLER)

FACE OF PANEL --4------1

TO SHT'G OVERALL WALL ASSEMBLY

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard. Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 84: SUBSTITUTION CSI Form 1.5C REQUEST

SILL TRIM --.......

SILL TRIM CLIP (BY SILL TRIM

INSTALLER)

LOCALIZED MEMBRANE -----I------f.......

(BY INSTALLER)

CFP -12 VERTICAL PANELS -----I

CONTINUOUS 'Z I GIRT ----'

(BY INSTALLER)

WINDOW/DOOR It--­ SYSTEM

(BY OTHERS)

\I~---+-

~T7H~-+--""""7""'------+-----'d-t'-"-'-'-'-'-t--

~,.y..;......:~:"-"'--~---':"""--4+:"""'-';'-+--

/-..........-?~M4i;-----.-----r---~oe::r------,f--'--,--f--

.---fl--'---+--- STUD WALL

I'~~--+--~:"-"'------+------ljfl---'----+-

I­__FACE OF PANEL TOSHTG

OVERALL WALL ASSEMBLY

'F,restone 1-800-426-7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12· WINDOW SILL DETAIL 12 • V9.2 WALL ASSEMBLY TYPE 2

VAPOR BARRIER "OPTIONAL"

(BY OTHERS)

SEAL or TAPE EDGES CONTINUOUS AND ALL PENETRATIONS PER MANUF.

RECOMMENDATIONS (BY INSTALLER)

WATER-RESISTIVE BARRIER (BY OTHERS)

INSULATION R-VALUE TO CODE (BY OTHERS)

(BY OTHERS)

EXTERIOR SHEATHING

(BY OTHERS)

-t---INTERIOR DRYWALL (BY OTHERS)

t¥9.2) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka. Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fox (763) 576-9596

Page 85: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1·800·426·7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • VERTICAL TRANSITIONS 12 • V10.1 WALL ASSEMBLY TYPE 1

5.000" 127.0mm

511 FORMED TRANSrnON STRIP wi REVEAL VERTICAL PANELS· STD. DETAIL

'.56",,1 ~ 3.000" 76.2mm

311 FORMED TRANSITION STRIP wi SEAL JOINT CFp· VERTICAL PANELS· OPTION IAI

(V10.1 ) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (BOO) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 86: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1·800·426·7737 www..firestonemetal.com

Delta Series WALL ASSEMBLY TYPE 1

CFP·12 • VERTICAL TRANSITIONS 12 • V10.2

VHB TAPE

ALUM EXTRUSION

ALUM EXTRUSION

5.000· 127.0mm

5" FORMED TRANSITION STRIP wI FLAT FACE CFP • VERTICAL PANELS· OPTION 'B'

5.000· 127.0mm

5" EXTRUDED TRANSITION STRIP wI REVEAL CFP • VERTICAL PANELS· 'C'

(V10.2) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 87: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone METAL PRODUCTS

1-800-426-7737 www.firestonemetal.com

Delta Series CFP·12· VERTICAL TRANSITIONS 12 • V10.3 WALL ASSEMBLY TYPE 1

ALUM EXTRUSION

ALUM EXTRUSION 3.625" 92.1mm

3-5/8" EXTRUDED TRANSITION STRIP wi REVEAL CFP ­ VERTICAL PANELS ­ OPTION IDI

ALUM EXTRUSION

ALUM EXTRUSION 127.0mm

511 EXTRUDED TRANSITION STRIP wi FLAT FACE CFP ­ VERTICAL PANELS ­ OPTION lEI

(V10.3) Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 88: SUBSTITUTION CSI Form 1.5C REQUEST

",restone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • PANEL SPLICE 12 • VB.1

~JU CFP-12 ~L VERTICAL PANELS

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka. Minnesota 55303

(9

INSTALL DIAGRAM

4" LAP

N UM

1------ WALLASSEMBLY

"-'''''=:---- EXTERIOR SHEATHING

-+0++--­ WATER RESISTIVE BARRIER

STARTER STRIP 1---+++---- "AS REQ'D"

FURRING OR GIRT ~.-+-1f:+--- "AS REQ'D" BY CODE

1+---+-+4--- LOWER PANEL

H++--w---------1f­ NOTCHED UPPER PANEL

TYPICAL PANEL I PANEL OVERLAP OTHER SPLICE OPTIONS AVAILABLE

NOTE: WHEN LAPPING PANEL 'D' OVER 'A' THE LEFT FASTENER FLANGE AND RIGHT HOOK FEATURE AT THE BOTTOM OF THE UPPER PANEL IS NOTCHED BACK TO CLEAR THE TOP OF THE LOWER PANEL.

Toll Free (800) 426-7737 Local (763) 576-9595 Fox (763) 576-9596

Page 89: SUBSTITUTION CSI Form 1.5C REQUEST

'F,restone METAL PRODUCTS

1·800·426·7737 www.firestonemetal.com

Delta Series CFP·12 • WDW OPENING 12 • VA.1

CFP·12 VERTICAL PANELS

Copyright 2011 © FIRESTONE METAL PRODUCTS

7007 Lund Boulevard. Anoka, Minnesota 55303

TYPICAL WINDOW OPENING APPLICATION SEALANTS NOT SHOWN FOR CLARITY

....,_1---­ METAL STUD

~~:---------- WATER RESISTIVE BARRIER

"'~----- EXTERIOR SHEATHING

FURRING OR GIRT "AS REQ'D" BY CODE

....-Io+-..::....,-~-- LOCALIZED FLEXIBLE MEMBRANE

'1----=---- METAL FLASHING

1--1-+------------ JAMB TRIM

1-+------------ LOCALIZED FLEXIBLE MEMBRANE

~-'F--- LOCALIZED FLEXIBLE MEMBRANE

./---.....=:o...:::--~- METAL SILL FLASHING

11+--- WATER RESISTIVE BARRIER

........----­ METAL STUD

Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 90: SUBSTITUTION CSI Form 1.5C REQUEST

'FIrestone 1-800-426-7737 www.firestonemetal.com METAL PRODUCTS

Delta Series CFP·12 • PENETRATION 12· VA.2

. JAMB TRIM w/FOAM CLOSURE STRIP

o o o o o o o

CFP -12 VERTICAL PANELS

TYPICAL BEAM PENETRATION APPLICATION SEALANTS NOT SHOWN FOR CLARITY DESIGN PROPER CLEARANCES TO ACCOMMODATE MOVEMENTS

t------- METAL STUD FURRING OR GIRT

,~~~------ "AS REQ'D" BY CODE

t------. EXTERIOR SHEATHING

...++-~~~::......:....-- LOCALIZED FLEXIBLE MEMBRANE

~----- METAL FLASHING

-r-------II-------+-- AnACHMENT FLANGE

~~--- STRUCTURAL MEMBER

t------- CLOSURE PLATE

......l----i------ WET SEAL CUT OUT PERIMETER

.......------""..-- LOCALIZED FLEXIBLE MEMBRANE

LMETALSTUD

+0+---- EXTERIOR SHEATHING

Ho+--- WATER RESISTIVE BARRIER

Copyright 2011© FIRESTONE METAL PRODUCTS

1001 Lund Boulevard, Anoka, Minnesota 55303 Toll Free (800) 426-7737 Local (763) 576-9595 Fax (763) 576-9596

Page 91: SUBSTITUTION CSI Form 1.5C REQUEST

Firestone Metal Products CFP-12 Section Properties 3/26/2011

Profile: CFP-12

Panel Fy Weight Maxo Ixe Sxe Maxo Ixe Sxe

Thickness KSI PSF KIP-IN IN4 /FT IN3 /FT KIP-IN IN4 /FT IN3 /FT

24-ga. 33 1.37 0.6130 0.0181 0.0310 1.2010 0.0370 0.060822-ga. 33 1.75 0.8780 0.0254 0.0444 1.6170 0.0495 0.081820-ga. 33 2.18 1.2190 0.0340 0.0617 2.1140 0.0640 0.107018-ga. 33 2.88 1.8860 0.0510 0.0955 2.9820 0.0900 0.1509

0.032 17 0.67 0.4780 0.0270 0.0470 0.8910 0.0530 0.08750.040 17 0.84 0.6670 0.0370 0.0654 1.1770 0.0700 0.1156

Notes:1) All properties were calculated in accordance with the 2007 NAS for the Design of Cold-Formed Steel Structural Members.

2) Maxo represents the allowable bending moment.

3) Ixe is for deflection determination.

4) Sxe is for bending calculations.

5) All of the above values are for one foot of panel width.

Aluminum

Negative MomentPositive Moment

Steel

Page 92: SUBSTITUTION CSI Form 1.5C REQUEST

Firestone Metal Products 3/26/2011

Profile: CFP-12

Panel Fy Weight Maxo Ixe Sxe Maxo Ixe Sxe

Thickness KSI PSF KIP-IN IN4 /FT IN3 /FT KIP-IN IN4 /FT IN3 /FT

Steel 24-ga. 33 1.37 0.6130 0.0181 0.0310 1.2010 0.0370 0.0608

29500 Modulus of Elasticity, E (KSI)0.0226 Material Thickness, t (IN)

1.09 Depth of the flat portion of the web measured along the plane of the web, h (IN)

Span Type Load Type 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00

Single Negative Wind 3202.67 800.67 355.85 200.17 128.11 88.96 65.36 50.04 39.54 32.03

Live 1634.67 408.67 181.63 102.17 65.39 45.41 33.36 25.54 20.18 16.35Shear 2438.77 1219.38 812.92 609.69 487.75 406.46 348.40 304.85 270.97 243.88

Web Crippling Exterior 182.18 91.09 60.73 45.54 36.44 30.36 26.03 22.77 20.24 18.22

Deflection (L/60) 37969.78 4746.22 1406.29 593.28 303.76 175.79 110.70 74.16 52.08 37.97

Deflection (L/180) 12656.59 1582.07 468.76 197.76 101.25 58.60 36.90 24.72 17.36 12.66Deflection (L/240) 9492.44 1186.56 351.57 148.32 75.94 43.95 27.67 18.54 13.02 9.49

Two Negative Wind 1634.67 408.67 181.63 102.17 65.39 45.41 33.36 25.54 20.18 16.35

Live 2906.07 726.52 322.90 181.63 116.24 80.72 59.31 45.41 35.88 29.06Shear 1951.01 975.51 650.34 487.75 390.20 325.17 278.72 243.88 216.78 195.10

Combined Bending & Shear 1666.19 618.90 312.17 185.18 121.71 85.81 63.63 49.02 38.90 31.60

Web Crippling Exterior 485.80 242.90 161.93 121.45 97.16 80.97 69.40 60.73 53.98 48.58

Web Crippling Interior 417.46 208.73 139.15 104.37 83.49 69.58 59.64 52.18 46.38 41.75

Deflection (L/60) 91463.66 11432.96 3387.54 1429.12 731.71 423.44 266.66 178.64 125.46 91.46

Deflection (L/180) 30487.89 3810.99 1129.18 476.37 243.90 141.15 88.89 59.55 41.82 30.49

Deflection (L/240) 22865.91 2858.24 846.89 357.28 182.93 105.86 66.66 44.66 31.37 22.87

Three Negative Wind 2043.33 510.83 227.04 127.71 81.73 56.76 41.70 31.93 25.23 20.43

Live 2554.17 638.54 283.80 159.64 102.17 70.95 52.13 39.91 31.53 25.54Shear 2032.31 1016.15 677.44 508.08 406.46 338.72 290.33 254.04 225.81 203.23

Combined Bending & Shear 1812.17 713.05 371.82 224.47 148.99 105.66 78.65 60.74 48.28 39.28

Web Crippling Exterior 455.44 227.72 151.81 113.86 91.09 75.91 65.06 56.93 50.60 45.54

Web Crippling Interior 474.39 237.19 158.13 118.60 94.88 79.06 67.77 59.30 52.71 47.44

Deflection (L/60) 71651.91 8956.49 2653.77 1119.56 573.22 331.72 208.90 139.95 98.29 71.65

Deflection (L/180) 23883.97 2985.50 884.59 373.19 191.07 110.57 69.63 46.65 32.76 23.88

Deflection (L/240) 17912.98 2239.12 663.44 279.89 143.30 82.93 52.22 34.99 24.57 17.91

Four Negative Wind 1907.87 476.97 211.99 119.24 76.31 53.00 38.94 29.81 23.55 19.08

Live 2646.80 661.70 294.09 165.43 105.87 73.52 54.02 41.36 32.68 26.47

Shear 2008.87 1004.43 669.62 502.22 401.77 334.81 286.98 251.11 223.21 200.89Combined Bending & Shear 1769.51 684.17 352.95 211.82 140.13 99.17 73.72 56.89 45.19 36.75

Web Crippling Exterior 463.55 231.78 154.52 115.89 92.71 77.26 66.22 57.94 51.51 46.36

Web Crippling Interior 456.54 228.27 152.18 114.14 91.31 76.09 65.22 57.07 50.73 45.65

Deflection (L/60) 76061.25 9507.66 2817.08 1188.46 608.49 352.14 221.75 148.56 104.34 76.06

Deflection (L/180) 25353.75 3169.22 939.03 396.15 202.83 117.38 73.92 49.52 34.78 25.35

Deflection (L/240) 19015.31 2376.91 704.27 297.11 152.12 88.03 55.44 37.14 26.08 19.02

Notes:

1) Allowable loads assume at least 1.5" of bearing surface.

2) Section properties and allowable loads were determined in accordance with the 2007 edition of the North American Specification for the Design of Cold-Formed Steel Structural Members.

3) The allowable loads are for uniform span lengths.

4) The allowable loads do not consider fastener pullout or pullover.

5) The panel self-weight was not added or subtracted from the allowable loads.

6) The section properties correspond to one foot of panel width.

Span (FT)

Positive Moment Negative Moment

Allowable Uniform Loads (PSF)

Page 93: SUBSTITUTION CSI Form 1.5C REQUEST

Firestone Metal Products 3/26/2011

Profile: CFP-12

Panel Fy Weight Maxo Ixe Sxe Maxo Ixe Sxe

Thickness KSI PSF KIP-IN IN4 /FT IN3 /FT KIP-IN IN4 /FT IN3 /FT

Steel 22-ga. 33 1.75 0.8780 0.0254 0.0444 1.6170 0.0495 0.0818

29500 Modulus of Elasticity, E (KSI)0.0289 Material Thickness, t (IN)

1.09 Depth of the flat portion of the web measured along the plane of the web, h (IN)

Span Type Load Type 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00

Single Negative Wind 4312.00 1078.00 479.11 269.50 172.48 119.78 88.00 67.38 53.23 43.12

Live 2341.33 585.33 260.15 146.33 93.65 65.04 47.78 36.58 28.91 23.41Shear 3118.60 1559.30 1039.53 779.65 623.72 519.77 445.51 389.82 346.51 311.86

Web Crippling Exterior 313.23 156.62 104.41 78.31 62.65 52.21 44.75 39.15 34.80 31.32

Deflection (L/60) 53283.56 6660.44 1973.47 832.56 426.27 246.68 155.35 104.07 73.09 53.28

Deflection (L/180) 17761.19 2220.15 657.82 277.52 142.09 82.23 51.78 34.69 24.36 17.76Deflection (L/240) 13320.89 1665.11 493.37 208.14 106.57 61.67 38.84 26.02 18.27 13.32

Two Negative Wind 2341.33 585.33 260.15 146.33 93.65 65.04 47.78 36.58 28.91 23.41

Live 4162.37 1040.59 462.49 260.15 166.49 115.62 84.95 65.04 51.39 41.62Shear 2494.88 1247.44 831.63 623.72 498.98 415.81 356.41 311.86 277.21 249.49

Combined Bending & Shear 2159.47 815.64 415.14 247.39 163.02 115.10 85.43 65.86 52.28 42.49

Web Crippling Exterior 835.28 417.64 278.43 208.82 167.06 139.21 119.33 104.41 92.81 83.53

Web Crippling Interior 703.10 351.55 234.37 175.78 140.62 117.18 100.44 87.89 78.12 70.31

Deflection (L/60) 128352.31 16044.04 4753.79 2005.50 1026.82 594.22 374.20 250.69 176.07 128.35

Deflection (L/180) 42784.10 5348.01 1584.60 668.50 342.27 198.07 124.73 83.56 58.69 42.78

Deflection (L/240) 32088.08 4011.01 1188.45 501.38 256.70 148.56 93.55 62.67 44.02 32.09

Three Negative Wind 2926.67 731.67 325.19 182.92 117.07 81.30 59.73 45.73 36.13 29.27

Live 3658.33 914.58 406.48 228.65 146.33 101.62 74.66 57.16 45.16 36.58Shear 2598.83 1299.42 866.28 649.71 519.77 433.14 371.26 324.85 288.76 259.88

Combined Bending & Shear 2340.93 935.36 492.63 299.06 199.15 141.51 105.47 81.52 64.84 52.78

Web Crippling Exterior 783.08 391.54 261.03 195.77 156.62 130.51 111.87 97.88 87.01 78.31

Web Crippling Interior 798.98 399.49 266.33 199.74 159.80 133.16 114.14 99.87 88.78 79.90

Deflection (L/60) 100550.19 12568.77 3724.08 1571.10 804.40 465.51 293.15 196.39 137.93 100.55

Deflection (L/180) 33516.73 4189.59 1241.36 523.70 268.13 155.17 97.72 65.46 45.98 33.52

Deflection (L/240) 25137.55 3142.19 931.02 392.77 201.10 116.38 73.29 49.10 34.48 25.14

Four Negative Wind 2732.65 683.16 303.63 170.79 109.31 75.91 55.77 42.70 33.74 27.33

Live 3791.02 947.75 421.22 236.94 151.64 105.31 77.37 59.23 46.80 37.91

Shear 2568.86 1284.43 856.29 642.22 513.77 428.14 366.98 321.11 285.43 256.89Combined Bending & Shear 2288.03 898.80 468.20 282.48 187.43 132.89 98.91 76.38 60.71 49.39

Web Crippling Exterior 797.02 398.51 265.67 199.26 159.40 132.84 113.86 99.63 88.56 79.70

Web Crippling Interior 768.92 384.46 256.31 192.23 153.78 128.15 109.85 96.12 85.44 76.89

Deflection (L/60) 106737.89 13342.24 3953.26 1667.78 853.90 494.16 311.19 208.47 146.42 106.74

Deflection (L/180) 35579.30 4447.41 1317.75 555.93 284.63 164.72 103.73 69.49 48.81 35.58

Deflection (L/240) 26684.47 3335.56 988.31 416.94 213.48 123.54 77.80 52.12 36.60 26.68

Notes:

1) Allowable loads assume at least 1.5" of bearing surface.

2) Section properties and allowable loads were determined in accordance with the 2007 edition of the North American Specification for the Design of Cold-Formed Steel Structural Members.

3) The allowable loads are for uniform span lengths.

4) The allowable loads do not consider fastener pullout or pullover.

5) The panel self-weight was not added or subtracted from the allowable loads.

6) The section properties correspond to one foot of panel width.

Span (FT)

Positive Moment Negative Moment

Allowable Uniform Loads (PSF)

Page 94: SUBSTITUTION CSI Form 1.5C REQUEST

Firestone Metal Products 3/26/2011

Profile: CFP-12

Panel Fy Weight Maxo Ixe Sxe Maxo Ixe Sxe

Thickness KSI PSF KIP-IN IN4 /FT IN3 /FT KIP-IN IN4 /FT IN3 /FT

Steel 20-ga. 33 2.18 1.2190 0.0340 0.0617 2.1140 0.0640 0.1070

29500 Modulus of Elasticity, E (KSI)0.0359 Material Thickness, t (IN)

1.09 Depth of the flat portion of the web measured along the plane of the web, h (IN)

Span Type Load Type 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00

Single Negative Wind 5637.33 1409.33 626.37 352.33 225.49 156.59 115.05 88.08 69.60 56.37

Live 3250.67 812.67 361.19 203.17 130.03 90.30 66.34 50.79 40.13 32.51Shear 3873.97 1936.98 1291.32 968.49 774.79 645.66 553.42 484.25 430.44 387.40

Web Crippling Exterior 498.92 249.46 166.31 124.73 99.78 83.15 71.27 62.36 55.44 49.89

Deflection (L/60) 71324.44 8915.56 2641.65 1114.44 570.60 330.21 207.94 139.31 97.84 71.32

Deflection (L/180) 23774.81 2971.85 880.55 371.48 190.20 110.07 69.31 46.44 32.61 23.77Deflection (L/240) 17831.11 2228.89 660.41 278.61 142.65 82.55 51.99 34.83 24.46 17.83

Two Negative Wind 3250.67 812.67 361.19 203.17 130.03 90.30 66.34 50.79 40.13 32.51

Live 5637.33 1409.33 626.37 352.33 225.49 156.59 115.05 88.08 69.60 56.37Shear 3099.18 1549.59 1033.06 774.79 619.84 516.53 442.74 387.40 344.35 309.92

Combined Bending & Shear 2715.82 1042.62 535.61 320.73 211.91 149.86 111.35 85.89 68.22 55.46

Web Crippling Exterior 1330.45 665.23 443.48 332.61 266.09 221.74 190.06 166.31 147.83 133.05

Web Crippling Interior 1105.33 552.67 368.44 276.33 221.07 184.22 157.90 138.17 122.81 110.53

Deflection (L/60) 171810.19 21476.27 6363.34 2684.53 1374.48 795.42 500.90 335.57 235.68 171.81

Deflection (L/180) 57270.06 7158.76 2121.11 894.84 458.16 265.14 166.97 111.86 78.56 57.27

Deflection (L/240) 42952.55 5369.07 1590.84 671.13 343.62 198.85 125.23 83.89 58.92 42.95

Three Negative Wind 4063.33 1015.83 451.48 253.96 162.53 112.87 82.93 63.49 50.16 40.63

Live 5079.17 1269.79 564.35 317.45 203.17 141.09 103.66 79.36 62.71 50.79Shear 3228.31 1614.15 1076.10 807.08 645.66 538.05 461.19 403.54 358.70 322.83

Combined Bending & Shear 2934.96 1190.12 633.11 386.60 258.32 183.95 137.29 106.22 84.54 68.85

Web Crippling Exterior 1247.30 623.65 415.77 311.82 249.46 207.88 178.19 155.91 138.59 124.73

Web Crippling Interior 1256.06 628.03 418.69 314.02 251.21 209.34 179.44 157.01 139.56 125.61

Deflection (L/60) 134594.74 16824.34 4984.99 2103.04 1076.76 623.12 392.40 262.88 184.63 134.59

Deflection (L/180) 44864.91 5608.11 1661.66 701.01 358.92 207.71 130.80 87.63 61.54 44.86

Deflection (L/240) 33648.68 4206.09 1246.25 525.76 269.19 155.78 98.10 65.72 46.16 33.65

Four Negative Wind 3793.96 948.49 421.55 237.12 151.76 105.39 77.43 59.28 46.84 37.94

Live 5263.39 1315.85 584.82 328.96 210.54 146.21 107.42 82.24 64.98 52.63

Shear 3191.08 1595.54 1063.69 797.77 638.22 531.85 455.87 398.88 354.56 319.11Combined Bending & Shear 2871.20 1145.26 602.48 365.52 243.31 172.84 128.80 99.55 79.18 64.44

Web Crippling Exterior 1269.51 634.76 423.17 317.38 253.90 211.59 181.36 158.69 141.06 126.95

Web Crippling Interior 1208.81 604.40 402.94 302.20 241.76 201.47 172.69 151.10 134.31 120.88

Deflection (L/60) 142877.49 17859.69 5291.76 2232.46 1143.02 661.47 416.55 279.06 195.99 142.88

Deflection (L/180) 47625.83 5953.23 1763.92 744.15 381.01 220.49 138.85 93.02 65.33 47.63

Deflection (L/240) 35719.37 4464.92 1322.94 558.12 285.75 165.37 104.14 69.76 49.00 35.72

Notes:

1) Allowable loads assume at least 1.5" of bearing surface.

2) Section properties and allowable loads were determined in accordance with the 2007 edition of the North American Specification for the Design of Cold-Formed Steel Structural Members.

3) The allowable loads are for uniform span lengths.

4) The allowable loads do not consider fastener pullout or pullover.

5) The panel self-weight was not added or subtracted from the allowable loads.

6) The section properties correspond to one foot of panel width.

Span (FT)

Allowable Uniform Loads (PSF)

Positive Moment Negative Moment

Page 95: SUBSTITUTION CSI Form 1.5C REQUEST

Firestone Metal Products 3/26/2011

Profile: CFP-12

Panel Fy Weight Maxo Ixe Sxe Maxo Ixe Sxe

Thickness KSI PSF KIP-IN IN4 /FT IN3 /FT KIP-IN IN4 /FT IN3 /FT

Steel 18-ga. 33 2.88 1.8860 0.0510 0.0955 2.9820 0.0900 0.1509

29500 Modulus of Elasticity, E (KSI)0.0475 Material Thickness, t (IN)

1.09 Depth of the flat portion of the web measured along the plane of the web, h (IN)

Span Type Load Type 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00

Single Negative Wind 7952.00 1988.00 883.56 497.00 318.08 220.89 162.29 124.25 98.17 79.52

Live 5029.33 1257.33 558.81 314.33 201.17 139.70 102.64 78.58 62.09 50.29Shear 5125.73 2562.86 1708.58 1281.43 1025.15 854.29 732.25 640.72 569.53 512.57

Web Crippling Exterior 898.13 449.07 299.38 224.53 179.63 149.69 128.30 112.27 99.79 89.81

Deflection (L/60) 106986.67 13373.33 3962.47 1671.67 855.89 495.31 311.91 208.96 146.76 106.99

Deflection (L/180) 35662.22 4457.78 1320.82 557.22 285.30 165.10 103.97 69.65 48.92 35.66Deflection (L/240) 26746.67 3343.33 990.62 417.92 213.97 123.83 77.98 52.24 36.69 26.75

Two Negative Wind 5029.33 1257.33 558.81 314.33 201.17 139.70 102.64 78.58 62.09 50.29

Live 7952.00 1988.00 883.56 497.00 318.08 220.89 162.29 124.25 98.17 79.52Shear 4100.58 2050.29 1366.86 1025.15 820.12 683.43 585.80 512.57 455.62 410.06

Combined Bending & Shear 3644.55 1427.24 742.03 447.21 296.56 210.18 156.40 120.75 95.97 78.07

Web Crippling Exterior 2395.02 1197.51 798.34 598.75 479.00 399.17 342.15 299.38 266.11 239.50

Web Crippling Interior 1966.80 983.40 655.60 491.70 393.36 327.80 280.97 245.85 218.53 196.68

Deflection (L/60) 257715.28 32214.41 9545.01 4026.80 2061.72 1193.13 751.36 503.35 353.52 257.72

Deflection (L/180) 85905.09 10738.14 3181.67 1342.27 687.24 397.71 250.45 167.78 117.84 85.91

Deflection (L/240) 64428.82 8053.60 2386.25 1006.70 515.43 298.28 187.84 125.84 88.38 64.43

Three Negative Wind 6286.67 1571.67 698.52 392.92 251.47 174.63 128.30 98.23 77.61 62.87

Live 7858.33 1964.58 873.15 491.15 314.33 218.29 160.37 122.79 97.02 78.58Shear 4271.44 2135.72 1423.81 1067.86 854.29 711.91 610.21 533.93 474.60 427.14

Combined Bending & Shear 3924.43 1619.72 872.68 536.99 360.47 257.43 192.50 149.13 118.81 96.81

Web Crippling Exterior 2245.33 1122.67 748.44 561.33 449.07 374.22 320.76 280.67 249.48 224.53

Web Crippling Interior 2235.00 1117.50 745.00 558.75 447.00 372.50 319.29 279.37 248.33 223.50

Deflection (L/60) 201892.11 25236.51 7477.49 3154.56 1615.14 934.69 588.61 394.32 276.94 201.89

Deflection (L/180) 67297.37 8412.17 2492.50 1051.52 538.38 311.56 196.20 131.44 92.31 67.30

Deflection (L/240) 50473.03 6309.13 1869.37 788.64 403.78 233.67 147.15 98.58 69.24 50.47

Four Negative Wind 5869.90 1467.48 652.21 366.87 234.80 163.05 119.79 91.72 72.47 58.70

Live 8143.35 2035.84 904.82 508.96 325.73 226.20 166.19 127.24 100.54 81.43

Shear 4222.18 2111.09 1407.39 1055.54 844.44 703.70 603.17 527.77 469.13 422.22Combined Bending & Shear 3843.18 1561.49 831.83 508.36 339.85 242.07 180.71 139.83 111.31 90.65

Web Crippling Exterior 2285.32 1142.66 761.77 571.33 457.06 380.89 326.47 285.67 253.92 228.53

Web Crippling Interior 2150.92 1075.46 716.97 537.73 430.18 358.49 307.27 268.86 238.99 215.09

Deflection (L/60) 214316.24 26789.53 7937.64 3348.69 1714.53 992.20 624.83 418.59 293.99 214.32

Deflection (L/180) 71438.75 8929.84 2645.88 1116.23 571.51 330.73 208.28 139.53 98.00 71.44

Deflection (L/240) 53579.06 6697.38 1984.41 837.17 428.63 248.05 156.21 104.65 73.50 53.58

Notes:

1) Allowable loads assume at least 1.5" of bearing surface.

2) Section properties and allowable loads were determined in accordance with the 2007 edition of the North American Specification for the Design of Cold-Formed Steel Structural Members.

3) The allowable loads are for uniform span lengths.

4) The allowable loads do not consider fastener pullout or pullover.

5) The panel self-weight was not added or subtracted from the allowable loads.

6) The section properties correspond to one foot of panel width.

Positive Moment Negative Moment

Allowable Uniform Loads (PSF)

Span (FT)

Page 96: SUBSTITUTION CSI Form 1.5C REQUEST

Firestone Metal Products 3/26/2011

Profile: CFP-12

Panel Fy Weight Maxo Ixe Sxe Maxo Ixe Sxe

Thickness KSI PSF KIP-IN IN4 /FT IN3 /FT KIP-IN IN4 /FT IN3 /FT

Aluminum 0.032 17 0.67 0.4780 0.0270 0.0470 0.8910 0.0530 0.0875

10,300 Modulus of Elasticity, E (KSI)0.032 Material Thickness, t (IN)1.09 Depth of the flat portion of the web measured along the plane of the web, h (IN)

Span Type Load Type 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00

Single Negative Wind 2376.00 594.00 264.00 148.50 95.04 66.00 48.49 37.13 29.33 23.76

Live 1274.67 318.67 141.63 79.67 50.99 35.41 26.01 19.92 15.74 12.75Shear 1778.88 889.44 592.96 444.72 355.78 296.48 254.13 222.36 197.65 177.89

Web Crippling Exterior 201.06 100.53 67.02 50.27 40.21 33.51 28.72 25.13 22.34 20.11

Deflection (L/60) 19776.00 2472.00 732.44 309.00 158.21 91.56 57.66 38.63 27.13 19.78

Deflection (L/180) 6592.00 824.00 244.15 103.00 52.74 30.52 19.22 12.88 9.04 6.59Deflection (L/240) 4944.00 618.00 183.11 77.25 39.55 22.89 14.41 9.66 6.78 4.94

Two Negative Wind 1274.67 318.67 141.63 79.67 50.99 35.41 26.01 19.92 15.74 12.75

Live 2266.07 566.52 251.79 141.63 90.64 62.95 46.25 35.41 27.98 22.66Shear 1423.10 711.55 474.37 355.78 284.62 237.18 203.30 177.89 158.12 142.31

Combined Bending & Shear 1220.87 456.00 230.68 137.04 90.15 63.58 47.17 36.34 28.84 23.44

Web Crippling Exterior 536.16 268.08 178.72 134.04 107.23 89.36 76.59 67.02 59.57 53.62

Web Crippling Interior 448.31 224.16 149.44 112.08 89.66 74.72 64.04 56.04 49.81 44.83

Deflection (L/60) 47637.50 5954.69 1764.35 744.34 381.10 220.54 138.88 93.04 65.35 47.64

Deflection (L/180) 15879.17 1984.90 588.12 248.11 127.03 73.51 46.29 31.01 21.78 15.88

Deflection (L/240) 11909.38 1488.67 441.09 186.08 95.28 55.14 34.72 23.26 16.34 11.91

Three Negative Wind 1593.33 398.33 177.04 99.58 63.73 44.26 32.52 24.90 19.67 15.93

Live 1991.67 497.92 221.30 124.48 79.67 55.32 40.65 31.12 24.59 19.92Shear 1482.40 741.20 494.13 370.60 296.48 247.07 211.77 185.30 164.71 148.24

Combined Bending & Shear 1326.36 524.57 274.43 165.97 110.28 78.25 58.27 45.02 35.79 29.12

Web Crippling Exterior 502.65 251.33 167.55 125.66 100.53 83.78 71.81 62.83 55.85 50.27

Web Crippling Interior 509.45 254.72 169.82 127.36 101.89 84.91 72.78 63.68 56.61 50.94

Deflection (L/60) 37318.84 4664.86 1382.18 583.11 298.55 172.77 108.80 72.89 51.19 37.32

Deflection (L/180) 12439.61 1554.95 460.73 194.37 99.52 57.59 36.27 24.30 17.06 12.44

Deflection (L/240) 9329.71 1166.21 345.54 145.78 74.64 43.19 27.20 18.22 12.80 9.33

Four Negative Wind 1487.71 371.93 165.30 92.98 59.51 41.33 30.36 23.25 18.37 14.88

Live 2063.90 515.98 229.32 128.99 82.56 57.33 42.12 32.25 25.48 20.64

Shear 1465.30 732.65 488.43 366.33 293.06 244.22 209.33 183.16 162.81 146.53Combined Bending & Shear 1295.56 503.57 260.60 156.67 103.74 73.46 54.63 42.17 33.50 27.25

Web Crippling Exterior 511.60 255.80 170.53 127.90 102.32 85.27 73.09 63.95 56.84 51.16

Web Crippling Interior 490.28 245.14 163.43 122.57 98.06 81.71 70.04 61.29 54.48 49.03

Deflection (L/60) 39615.38 4951.92 1467.24 618.99 316.92 183.40 115.50 77.37 54.34 39.62

Deflection (L/180) 13205.13 1650.64 489.08 206.33 105.64 61.13 38.50 25.79 18.11 13.21

Deflection (L/240) 9903.85 1237.98 366.81 154.75 79.23 45.85 28.87 19.34 13.59 9.90

Notes:

1) Allowable loads assume at least 1.5" of bearing surface.

2) Section properties and allowable loads were determined in accordance with the 2007 edition of the North American Specification for the Design of Cold-Formed Steel Structural Members.

3) The allowable loads are for uniform span lengths.

4) The allowable loads do not consider fastener pullout or pullover.

5) The panel self-weight was not added or subtracted from the allowable loads.

6) The section properties correspond to one foot of panel width.

Positive Moment Negative Moment

Allowable Uniform Loads (PSF)

Span (FT)

Page 97: SUBSTITUTION CSI Form 1.5C REQUEST

Firestone Metal Products 3/26/2011

Profile: CFP-12

Panel Fy Weight Maxo Ixe Sxe Maxo Ixe Sxe

Thickness KSI PSF KIP-IN IN4 /FT IN3 /FT KIP-IN IN4 /FT IN3 /FT

Aluminum 0.040 17 0.84 0.6670 0.0370 0.0654 1.1770 0.0700 0.1156

10,300 Modulus of Elasticity, E (KSI)0.040 Material Thickness, t (IN)1.09 Depth of the flat portion of the web measured along the plane of the web, h (IN)

Span Type Load Type 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00

Single Negative Wind 3138.67 784.67 348.74 196.17 125.55 87.19 64.05 49.04 38.75 31.39

Live 1778.67 444.67 197.63 111.17 71.15 49.41 36.30 27.79 21.96 17.79Shear 2223.60 1111.80 741.20 555.90 444.72 370.60 317.66 277.95 247.07 222.36

Web Crippling Exterior 323.03 161.51 107.68 80.76 64.61 53.84 46.15 40.38 35.89 32.30

Deflection (L/60) 27100.44 3387.56 1003.72 423.44 216.80 125.47 79.01 52.93 37.17 27.10

Deflection (L/180) 9033.48 1129.19 334.57 141.15 72.27 41.82 26.34 17.64 12.39 9.03Deflection (L/240) 6775.11 846.89 250.93 105.86 54.20 31.37 19.75 13.23 9.29 6.78

Two Negative Wind 1778.67 444.67 197.63 111.17 71.15 49.41 36.30 27.79 21.96 17.79

Live 3138.67 784.67 348.74 196.17 125.55 87.19 64.05 49.04 38.75 31.39Shear 1778.88 889.44 592.96 444.72 355.78 296.48 254.13 222.36 197.65 177.89

Combined Bending & Shear 1547.60 588.42 300.60 179.48 118.39 83.64 62.11 47.89 38.03 30.91

Web Crippling Exterior 861.41 430.70 287.14 215.35 172.28 143.57 123.06 107.68 95.71 86.14

Web Crippling Interior 712.01 356.00 237.34 178.00 142.40 118.67 101.72 89.00 79.11 71.20

Deflection (L/60) 65281.02 8160.13 2417.82 1020.02 522.25 302.23 190.32 127.50 89.55 65.28

Deflection (L/180) 21760.34 2720.04 805.94 340.01 174.08 100.74 63.44 42.50 29.85 21.76

Deflection (L/240) 16320.25 2040.03 604.45 255.00 130.56 75.56 47.58 31.88 22.39 16.32

Three Negative Wind 2223.33 555.83 247.04 138.96 88.93 61.76 45.37 34.74 27.45 22.23

Live 2779.17 694.79 308.80 173.70 111.17 77.20 56.72 43.42 34.31 27.79Shear 1853.00 926.50 617.67 463.25 370.60 308.83 264.71 231.63 205.89 185.30

Combined Bending & Shear 1675.52 673.52 356.16 216.72 144.51 102.77 76.64 59.26 47.15 38.38

Web Crippling Exterior 807.57 403.78 269.19 201.89 161.51 134.59 115.37 100.95 89.73 80.76

Web Crippling Interior 809.10 404.55 269.70 202.27 161.82 134.85 115.59 101.14 89.90 80.91

Deflection (L/60) 51140.63 6392.58 1894.10 799.07 409.13 236.76 149.10 99.88 70.15 51.14

Deflection (L/180) 17046.88 2130.86 631.37 266.36 136.38 78.92 49.70 33.29 23.38 17.05

Deflection (L/240) 12785.16 1598.14 473.52 199.77 102.28 59.19 37.27 24.97 17.54 12.79

Four Negative Wind 2075.94 518.99 230.66 129.75 83.04 57.67 42.37 32.44 25.63 20.76

Live 2879.97 719.99 320.00 180.00 115.20 80.00 58.77 45.00 35.56 28.80

Shear 1831.63 915.82 610.54 457.91 366.33 305.27 261.66 228.95 203.51 183.16Combined Bending & Shear 1638.26 647.58 338.67 204.78 136.05 96.53 71.88 55.53 44.15 35.92

Web Crippling Exterior 821.95 410.98 273.98 205.49 164.39 136.99 117.42 102.74 91.33 82.20

Web Crippling Interior 778.66 389.33 259.55 194.66 155.73 129.78 111.24 97.33 86.52 77.87

Deflection (L/60) 54287.75 6785.97 2010.66 848.25 434.30 251.33 158.27 106.03 74.47 54.29

Deflection (L/180) 18095.92 2261.99 670.22 282.75 144.77 83.78 52.76 35.34 24.82 18.10

Deflection (L/240) 13571.94 1696.49 502.66 212.06 108.58 62.83 39.57 26.51 18.62 13.57

Notes:

1) Allowable loads assume at least 1.5" of bearing surface.

2) Section properties and allowable loads were determined in accordance with the 2007 edition of the North American Specification for the Design of Cold-Formed Steel Structural Members.

3) The allowable loads are for uniform span lengths.

4) The allowable loads do not consider fastener pullout or pullover.

5) The panel self-weight was not added or subtracted from the allowable loads.

6) The section properties correspond to one foot of panel width.

Positive Moment Negative Moment

Allowable Uniform Loads (PSF)

Span (FT)

Page 98: SUBSTITUTION CSI Form 1.5C REQUEST
Page 99: SUBSTITUTION CSI Form 1.5C REQUEST
Page 100: SUBSTITUTION CSI Form 1.5C REQUEST
Page 101: SUBSTITUTION CSI Form 1.5C REQUEST
Page 102: SUBSTITUTION CSI Form 1.5C REQUEST
Page 103: SUBSTITUTION CSI Form 1.5C REQUEST
Page 104: SUBSTITUTION CSI Form 1.5C REQUEST
Page 105: SUBSTITUTION CSI Form 1.5C REQUEST