3 3A. VD Pipe Ultraweld Connection3B. PT Ultraweld Connection3C. PS Ultraweld Connection3D. GO Ultraweld Connection3E. RT Ultraweld Connection3F. Copper Ground Mesh
2A. CPC Series Pipe Clamp2B. Tinned Conductor2C. Fence Fabric Grounding Clamp2D. VD Pipe Ultraweld Connection2E. Flexible Gate Jumper
2A
2B
2C
2E
2D
3D
3C3B3A
3E
3F
21A. GS Ultraweld Connection1B. HD Ultraweld Connection1C. Copper Clad Ground Rod1D. RE Ultraweld Connection
1D
1C
1B1A
1
5
6
Harger provides a complete line of grounding, bonding and lightning protection products for substations. Harger’s leading tech support can help provide solutions for your substation grounding requirements.
4
4 4A. Stainless Steel Enhanced Ground Rod4B. Ground Access Well4C. Ultrafi ll4D. Grounding Conductor
5 5A. Air Terminal Assembly5B. Ridge Saddle Assembly5C. Aluminum LP Conductor5D. Bi-Metal Cable Connector5E. Bonding Plate5F. Copper LP Conductor
4D
4C
4B
4A
6D
6E
6F
6C
6B
6A
5D
5E
5F
6G
6H
5C
5B
5A
6 6A. Flat Braid Bonding Strap6B. VA Ultraweld Connection6C. Personnel Safety Mat6D. XO Ultraweld Connection6E. RT Ultraweld Connection6F. VD Pipe Ultraweld Connection6G. Flexible Gate Jumper6H. VD Ultraweld Connection
Exothermic ConnectionsProperly installed exothermic connections are essential to the grid integrity and system reliability for the life of the substation, as well as ensuring safe conditions for workers and the general public.
Harger offers two systems for making exothermic connections, UltraShot & NUWTube.
VTRE VD
GO
HD
XO
RP
RT
VA
PS PTGS
ULTRASH T® • The patented electric ignition system, produces a high quality connection while eliminating the inconsistencies associated with using the old starting powder process. The elimination of
the starting powder has also been shown to reduce emissions and extend mold life.
• New UltraShot Controller uses an 18v Milwaukee lithium ion battery that makes it easier to charge and use.
• The system provides superior safety by allowing the user to maintain a safe distance from the reaction during ignition.
• Reduces labor and material costs due to misfi res.
• Uses the traditional method of ignition with starting powder.
• Innovative dual chamber design keeps weld metal and starting powder separate until point of use.
• Reduces material and labor costs by eliminating migrating starting powder issues.
Step & Touch Voltage
Touch VoltageEliminate Touch Voltage Threats by providing additional ground conductors in the area of the Touch Voltage hazard such as a switch handle.Options include: • Personnel Safety Mats • Counterpoise Wires
Step VoltageEliminate Step Voltage Threats by providing additional ground conductors (electrodes) in the area of the step voltage hazard such as the perimeter of the Substation Grid.Options include: • Additional Grid Conductor • Additional Ground Rods • Use of Deep Driven Ground Rods • Prefabricated Wire Mesh
Harger Lightning & Grounding301 Ziegler Drive, Grayslake, IL 60030
p. 800.842.7437 • 847.548.8700f. 847.548.8755
www.harger.com • [email protected] - 7.14