Studies on fast ion distribution
Correlated with
the spectroscopy diagnostics measurements
Gerarda Apruzzesehttp://www.afs.enea.it/apruzzes/
CRE Frascati - ENEA
Culham, July the 24th
Aim of this work
• Analysis of the positive and negative aspects of the diagnostics using the CX spectrum
and
• their possible development at JET
Diagnostics compared in the analysis
• the diagnostic FIDA
developed in DIII-D W.W.Heidbrink et al., PPCF 49, (2007) 1457-1475
• the fast ion CXRS diagnostic
developed in Textor Proceedings of the 17th Topical Conference on High-
Temperature Plasma Diagnostics, Albuquerque, New Mexico, May 2008
FIDA Diagnostic( Fast Ion D Analysis)
• Measurement of the vertical component of perpendicular energy
• CX emission spectrum of re-neutrals generated by beam: CX ( beam - plasma ions) fast ions CX ( fast ions – beam ) re-neutrals
FIDA measurements in DIII-D
Successful on DIII-D in detecting both NB and ICRH accelerated D
Y.Luo and W.W. Heidbrink, RSI 78, 033505 (2007)
For FIDA success it is necessary
• Vertical views ( Doppler shift only due to gyromotion of fast ions)
• Good hardware ( f# of spectrometer, detector, system for avoiding detector saturation)
• Beam modulation ( for subtracting the background)
Complications of FIDA
• The extracted signal is 10 times less the detected signal so
GOOD HARDWARE and APPROPRIATE OPTICAL
VIEW are required
• Spectral overlap with BES spectrum• Intense cold Dalpha light • Halo (from CX plasma-beam)
The fast ion CXRS diagnostic
• Using the Fokker-Plank code to simulate the D beam emission spectrum
• Good results on Textor, where a favourable viewing geometry permits to separate the contributions due to the fast ions and the beam emission spectrum (BES)
CX measurements at TEXTOR
Red wing (BES)
Blu wing (slowing down)
spectrum simulation
Situation at JET
• First and preliminary analysis done by von Hellermann and Delabie using the technique of fast ion CX diagnostic. Good results.
http://users.jet.efda.org/pages/d-task-force/meetings/2008/080626/Delabie.ppt
• FIDA diagnostic requires a vertical viewing line avoiding the divertor region (characterised by
strong emission) and dedicated equipment.
Next step
for FIDA : firstly, check of vertical view
for fast ion CX :– Prepare future upgrading of spectrometer (Textor
group)
– Extend the simulation modelling in order to include effects of instabilities on slowing down distribution function (Frascati and Textor groups)