of 88 4
Skill Check
• What is the minimum ceiling area which
must be at least 84” high
• The room is 20’ long x 12’wide.
5
of 88
Skill Check - answer
• What is the minimum
ceiling area which
must be at least 84”
high
• The room is 20’ long x
12’wide.
R305.1
8 of 88
Skill Check
True or False:
1. I am required to have a room called a “kitchen”
in my house.
2. I am required to have a bathroom in my house.
3. My kitchen sink can also be my bathroom
lavatory.
4. I am required to have a bathtub in my bathroom.
5. I can have a water closet in my kitchen.
6. I can have a refrigerator in my bathroom.
9
of 88
Skill Check - answer
R306
True or False: 1. I am required to have a room called a “kitchen” FALSE “Kitchen area”
in my house.
2. I am required to have a bathroom in my house. FALSE “toilet facilities”
3. My kitchen sink can also be my bathroom lavatory. TRUE
4. I am required to have a bathtub in my bathroom. FALSE tub or shower
5. I can have a water closet in my kitchen. TRUE
6. I can have a refrigerator in my bathroom. TRUE
12 of 88
Safety Glazing in Hazardous Locations
• Most common places for safety glazing:
• Adjacent to a
door
• Adjacent to a
walking surface
• Adjacent to a
tub or shower
• Adjacent to
bottom of stair
R308
15 of 88
Safety Glazing Adjacent to Walkway
• Must meet ALL 4 requirements
<18”
>36”
> 9 SQFT
R308.4.3
16 of 88
Safety Glazing Adjacent to Wet Surfaces
• Within 5’ horizontally and 5’ vertically
60”
≤ 60”
R308.4.5
27 of 88
EERO
• Window or door
• Minimum area: 5.7 sqft
• Minimum height: 24”
• Minimum width: 20”
R310.1.1, .2, .3
29 of 88
Interior Passage
• Kitchen + living area + egress door:
• 32” access to:
• Kitchen
• Living area
• (1) bedroom
• (1) bathroom
R311.2.1
34 of 88
Landing at Stairs
• Interior stairs
• Bottom of stairs
• Exterior stairs
• Top of stairs
• Bottom of stairs
R311.7.6
36 of 88
Skill Check
• Scenario:
Homeowner wants to convert his screen
porch to a sunroom. What might he have to
do with his stairs?
R311.7.6
37 of 88
Skill Check - answer
• Scenario:
Homeowner wants
to convert his
screen porch to a
sunroom. What
might he have to
do with his stairs?
R311.7.5
40 of 88
LANDINGS at STAIRWAYS
R311.7.5 Landings for stairways. There shall be a floor
or landing at the top and bottom of each stairway. A flight
of stairs shall not have a vertical rise larger than 12 feet
(3658 mm) between floor levels or landings. The width of
each landing shall not be less than the width of the stairway
served. Every landing shall have a minimum dimension of
36 inches (914 mm) measured in the direction of travel.
Exception: A floor or landing is not required at the top of
an interior flight of stairs, including stairs in an enclosed
garage, provided a door does not swing over the stairs.
42 of 88
Handrail Requirements
R311.7.6 Stairway walking surface. The walking surface
of treads and landings of stairways shall be sloped no steeper
than one unit vertical in 48 inches horizontal (2-percent slope).
R311.7.7 Handrails. Handrails shall be provided on at
least one side of each continuous run of treads or flight with
four or more risers. The continuous handrail required for
winders shall be located on the side where the tread is
narrower.
44 of 88
Handrail Height
R311.7.7.1 Height. Handrail height, measured vertically from
the sloped plane adjoining the tread nosing, or finish surface of
ramp slope, shall be not less than 30 inches (762 mm) and not
more than 38 inches (965 mm).
Exceptions:
1. The use of a volute, turnout or starting easing shall be
allowed over the lowest tread.
2. When handrail fittings or bendings are used to provide
continuous transition between flights, the transition from
handrail to guardrail, or used at the start of a flight, the
handrail height at the fittings or bendings shall be permitted to
exceed the maximum height.
46 of 88
Handrail Continuity
R311.7.7.2 Continuity. Handrails for stairways shall be
continuous for the full length of the flight, from a point directly
above the top riser of the flight to a point directly above the
lowest riser of the flight. Handrail ends shall be returned or
shall terminate in newel posts or safety terminals. Handrails
adjacent to a wall shall have a space of not less than 1 1/2 inch
(38 mm) between the wall and the handrails.
Exceptions:
1. Handrails shall be permitted to be interrupted by a newel post
at the turn.
2. The use of a volute, turnout, starting easing or starting
newel shall be allowed over the lowest tread.
49 of 88
Graspability
R311.7.7.3 Grip-size. All required handrails shall be of
one of the following types or provide equivalent
graspability.
1. Type I. Handrails with a circular cross section shall have an
outside diameter of at least 1 1/4 inches (32 mm) and not
greater than 2 inches (51 mm). If the handrail is not circular, it
shall have a perimeter dimension of at least 4 inches (102 mm)
and not greater than 6 1/4 inches (160 mm) with a maximum
cross section of dimension of 2 1/4 inches (57 mm). Edges
shall have a minimum radius of 0.01 inch (0.25 mm).
51 of 88
Graspability Cont.
2. Type II. Handrails with a perimeter greater than 6 1/4 inches
(160 mm) shall have a graspable finger recess area on both
sides of the profile. The finger recess shall begin within a
distance of 3/4 inch (19 mm) measured vertically from the
tallest portion of the profile and achieve a depth of at least
5/16 inch (8 mm) within 7/8 inch (22 mm) below the widest
portion of the profile. This required depth shall continue for at
least 3/8 inch (10 mm) to a level that is not less than 13/4
inches (45 mm) below the tallest portion of the profile. The
minimum width of the handrail above the recess shall be 11/4
inches (32 mm) to a maximum of 23/4 inches (70 mm).
Edges shall have a minimum radius of 0.01 inch (0.25 mm).
53 of 88
Illumination Requirements
R311.7.8 Illumination. All stairs shall be provided with
illumination in accordance with Section R303.6.
R303.6 Stairway illumination. All interior and exterior stairways
shall be provided with a means to illuminate the stairs, including
the landings and treads. Interior stairways shall be provided with
an artificial light source located in the immediate vicinity of each
landing of the stairway. For interior stairs the artificial light
sources shall be capable of illuminating treads and landings to
levels not less than 1 foot-candle (11 lux) measured at the center
of treads and landings. Exterior stairways shall be provided with
an artificial light source located in the immediate vicinity of the
top landing of the stairway.
55 of 88
Illumination Requirements Exterior stairways providing access to a basement from the
outside grade level shall be provided with an artificial light
source located in the immediate vicinity of the bottom landing of
the stairway.
Exception: An artificial light source is not required at the
top and bottom landing, provided an artificial light source is
located directly over each stairway section.
R303.6.1 Light activation. Where lighting outlets are
installed in interior stairways, there shall be a wall switch at
each floor level to control the lighting outlet where the stairway
has six or more risers. The illumination of exterior stairways shall
be controlled from inside the dwelling unit.
Exception: Lights that are continuously illuminated or
automatically controlled.
57 of 88
Additional Measure Tables
N1101.1 General.
All conditioned spaces within residential buildings shall
comply with Table N1101.1(1) and two additional measures
from Table N1101.1(2).
• One measure from Envelope Measures section
• Items 1 thru 6
• One measure from Conservation Measures section
• Items A thru G
Verify on plans which measures were used on the
residence
69 of 88
N1101.1(2) Duct Sealing Test
• Tested duct system: PTCS technician on
PTCS form. 6% leakage or less
• Measure 3, 5, or E
72 of 88
Smoke Detection Requirements
R314.1 Smoke detection and notification. All smoke alarms
shall be listed in accordance with UL 217 and installed in
accordance with the provisions of this code or the household
fire warning equipment provisions of NFPA 72.
73 of 88
Household Fire Alarm Systems R314.2 Smoke detection systems. Household fire alarm systems
installed in accordance with NFPA 72 that include smoke alarms,
or a combination of smoke detector and audible notification
device installed as required by this section for smoke alarms,
shall be permitted. The household fire alarm system shall provide
the same level of smoke detection and alarm as required by this
section for smoke alarms. Where a household fire warning
system is installed using a combination of smoke detector and
audible notification device(s), it shall become a permanent fixture
of the occupancy and owned by the homeowner. The system shall
be monitored by an approved supervising station and be
maintained in accordance with NFPA 72.
Exception: Where smoke alarms are provided meeting the
requirements of Section R314.4.
74 of 88
Smoke Detector Locations R314.3 Location. Smoke alarms shall be installed in the following
locations:
1. In each sleeping room.
2. Outside each separate sleeping area in the immediate
vicinity of the bedrooms.
3. On each additional story of the dwelling, including basements but
not including crawl spaces and uninhabitable attics. In dwellings or
dwelling units with split levels and without an intervening door
between the adjacent levels, a smoke alarm installed on the upper
level shall suffice for the adjacent lower level provided that the lower
level is less than one full story below the upper level.
When more than one smoke alarm is required to be installed
within an individual dwelling unit the alarm devices shall be
interconnected in such a manner that the actuation of one alarm
will activate all of the alarms in the individual unit.
75 of 88
Smoke Detector Locations
Required smoke alarms shall not be located within kitchens
or garages, or in other spaces where temperatures can fall
below40°F (5°C). Ionization smoke alarms shall not be located
closer than 3 feet (914 mm) horizontally from the following:
1. The door to a kitchen;
2. The door to a bathroom containing a tub or shower;
3. The supply registers of a forced air heating or cooling
system, outside the airflow from those registers.
A smoke alarm installed within 20 feet (6096 mm) (direct
linear path) of a cooking appliance shall be a photoelectric-
type smoke alarm or the alarm shall have an approved
alarm silencing means.
78 of 88
Alterations, Repairs & Additions
R314.3.1 Alterations, repairs and additions. When
alterations, repairs or additions requiring a structural permit
occur, or when one or more sleeping rooms are added or
created in existing dwellings, the individual dwelling unit shall
be equipped with smoke alarms located as required for new
dwellings.
Exception: Work involving the exterior surfaces of dwellings,
such as the replacement of roofing or siding, or the addition or
replacement of windows or doors, or the addition of a porch or
deck, are exempt from the requirements of this section.
79 Of 88
Alarm Power Source
R314.4 Power source. Smoke alarms shall receive their primary
power from the building wiring when such wiring is served from
a commercial source, and when primary power is interrupted,
shall receive power from a battery. Wiring shall be permanent
and without a disconnecting switch other than those required for
overcurrent protection. Smoke alarms shall be interconnected.
Exceptions:
1. Smoke alarms shall be permitted to be battery operated when
installed in buildings without commercial power.
2. Interconnection and hard-wiring of smoke alarms in existing
areas shall not be required where the alterations or repairs do not
result in the removal of interior wall or ceiling finishes exposing
the structure.
80 of 88
Carbon Monoxide Alarms
CARBON MONOXIDE ALARMS
R315.1 Carbon monoxide alarms. For new construction,
approved single station carbon monoxide alarms or a
household carbon monoxide detection system shall be
installed.
R315.2 Installation location. Carbon monoxide alarms
shall be located in each bedroom or within 15 feet (4572
mm) outside of each bedroom door. Bedrooms on
separate floor levels in a structure consisting of two or
more stories shall have separate carbon monoxide alarms
serving each story.
82 of 88
CO Alarm Requirements
R315.3 Alarm requirements.
R315.3.1 Single station alarm requirements. Single station
carbon monoxide alarms shall be listed as complying with UL
2034 and shall be installed in accordance with this code and the
manufacturer’s installation instructions.
R315.3.2 Household carbon monoxide detection systems.
Household carbon monoxide detection systems that include
carbon monoxide detectors and audible notification appliances,
installed in accordance with this section for carbon monoxide
alarms and NFPA 72 shall be permitted. The carbon monoxide
detectors shall be listed as complying with UL 2075.
83 of 88
Combination Detectors
R315.3.3 Combination smoke/carbon monoxide alarm
requirements. Combination smoke/carbon monoxide
alarms shall be listed as complying with UL 2034 and UL
217. Combination smoke/carbon monoxide detectors shall
be listed as complying with ANSI/UL 2075 and ANSI/UL
268. See Section R314 for additional requirements specific
to the installation of smoke alarms.
84 of 88
CO Power Sources R315.4 Power source.
R315.4.1 Carbon monoxide alarms. Single station carbon
monoxide alarms shall be battery operated, or may receive
their primary power from the building wiring system. Plug
in devices securely fastened to the structure and installed in
accordance with the manufacturer’s installation instructions
are deemed to satisfy this requirement. Hard wired and
plug-in carbon monoxide alarms shall be equipped with
battery back up.
R315.4.2 Household carbon monoxide detection systems.
Required power supply sources for household carbon
monoxide detection systems shall be in accordance with
NFPA 720.
85 of 88
Combination Smoke & CO Detectors
R315.4.3 Combination smoke/carbon monoxide alarms.
Combination smoke/carbon monoxide alarms/detectors shall
receive their primary power from the building wiring when such
wiring is served from a commercial source, and when primary
power is interrupted, shall receive power from a battery. Wiring
shall be permanent and without a disconnecting switch other
than those required for overcurrent protection. Smoke alarm
features of combination smoke/carbon monoxide
alarms/detectors shall be interconnected.
Exceptions: Interconnection and hard-wiring of combination
smoke/carbon monoxide alarms/detectors in existing areas shall
not be required where the alterations or repairs do not result in
the removal of interior wall or ceiling finishes exposing the
structure.
86 of 88
CO Detectors in Exist. Buildings
R315.5 Where required in existing dwellings. Where a new
carbon monoxide source is introduced or work requiring a
structural permit occurs in existing dwellings carbon
monoxide alarms shall be provided in accordance with
Section R315.1.
Exception: Work involving the exterior surfaces of dwellings,
such as the replacement of roofing or siding, or the addition or
replacement of windows or doors, or the addition of a porch or
deck, are exempt from the requirements of this section.