Page 1: Structural & Geotechnical Design of 50 Storey Tower

Structural & Geotechnical Design of 50 Storey Tower

(Chamber of Commerce) in Dammam City.

Final-Exam Presentation

Supervisor’s:

Engr. Danish Ahmed

Dr. Tahar Ayadat

Coordinator:

Dr. Andi Asiz

PRESENTED BY:

MOHANAD AL-OTAISHAN : 201300456

ABDULRAHMAN AL-AMER : 201300351

1 12/28/2017

Page 2: Structural & Geotechnical Design of 50 Storey Tower

Presentation

Outlines

CONCLUSION.

ACKNOWLEDGMENT.

COST ESTIMATION.

GEOTHECNICAL & FOUNDATION DESIGN.

ETABS ANALYSIS & DESIGN.

PRELIMINARY DESIGN & LOAD CALCULATIONS.

DESIGN CONSTRAINTS.

DESIGN CODES USED.

PROJECT DESCRIPTION.

OBJECTIVES.

2 12/28/2017

Page 3: Structural & Geotechnical Design of 50 Storey Tower

Project Objectives

Choosing an adequate structural

system.

Preliminary design of structural members.

Modeling using ETABS software for

design & analysis.

Geotechnical design of the foundation

system.

Writing technical

report

12/28/2017 3

Page 4: Structural & Geotechnical Design of 50 Storey Tower

Project Description

o Location:

Dammam City

o Commercial Tower

o 50 Floors

12/28/2017 4

Google maps

Page 5: Structural & Geotechnical Design of 50 Storey Tower

Project Description (Continues)

o Floors Area.

S.No Floor Area m2

1 Sub-Basement 3717.441

2 Basement 3717.441

3 Ground Floor 3717.441

4 Mezzanine 3717.441

5 Podiums 3717.441

6 First Group 1663.677

7 Second Group 1663.677

8 Third Group 1663.677

9 Fourth Group 1663.677

10 Fifth Group 1663.677

11 Sixth Group 1663.677

12 Seventh Group 1663.677

13 Eighth Group 1663.677

14 Roof Deck 1663.677

12/28/2017 5

Page 6: Structural & Geotechnical Design of 50 Storey Tower

o Tower 3D model

Reference: Arabtech Jardaneh

12/28/2017

Project Description (Continues)

6

Page 7: Structural & Geotechnical Design of 50 Storey Tower

CODES o Structural Design and Analysis codes:

- ACI 318-11 Code : American Concrete Institute

- SBC (301) : Saudi Building Code

o Geotechnical Design and Analysis:

- SBC(303): Saudi Building Code

- International Building Code (2009)

12/28/2017 7

Page 8: Structural & Geotechnical Design of 50 Storey Tower

DESIGN CONSTRAINTS

8 12/28/2017

Design

Constraints Project Application

Performance Several performance requirements were established

Serviceability Several factors considered such as durability, overall stability and

deflection limitations.

Economic Economical limitations were established

Environmental Did not affect our design

Environmental

Sustainability Did not affect our design

Manufacturability Being able to design a manufacturable building.

Ethical We did not violate any ethical rule as far as we are aware of.

Health and safety Several safety factors and precautions were taken into account in

designing process.

Social Did not affect our design

Political Did not affect our design

Page 9: Structural & Geotechnical Design of 50 Storey Tower

PRELIMINARY DESIGN & LOAD CALCULATION

9 12/28/2017

Page 10: Structural & Geotechnical Design of 50 Storey Tower

PRELIMINARY DESIGN

o Slab design

12/28/2017 10

o Slab

Type : Two Way Solid Slab – Flat Plate

Thickness : 37 cm

o Control deflection values.

o Satisfy shear requirements to prevent punching shear.

Page 11: Structural & Geotechnical Design of 50 Storey Tower

PRELIMINARY DESIGN(CONTINUOUS)

o Dead Load

12/28/2017 11

Dead Load Unit weight

(kN/m3) Thickness (m) W (kN/m2)

Sand 14 0.01 0.14

Mortar 20.5 0.01 0.205

Tile 23.5 0.01 0.235

Concrete Slab 24 0.37 8.88

Total service load per unit area W (kN/m2) 9.46

Page 12: Structural & Geotechnical Design of 50 Storey Tower

o Live Load

12/28/2017

PRELIMINARY DESIGN(CONTINUOUS)

12

Floor Live Load

(kN\m2)

Sub Basement 2

Basment 2

Ground Floor 5

Mezzanine 5

Podiums 2

First Group 2.5

Second Group 2.5

Third Group 2.5

Fourth Group 2.5

Fifth Group 2.5

Sixth Group 2.5

Seventh Group 2.5

Eighth Group 2.5

Roof Deck Floor 2.5

Page 13: Structural & Geotechnical Design of 50 Storey Tower

o Ultimate Floor Load

12/28/2017

PRELIMINARY DESIGN(CONTINUOUS)

13

Floor Live Load (kN\m2) Dead Load (kN\m2) Wu (kN\m2) = 1.2DL+1.6LL

Sub Basement 2 9.46 14.516

Basment 2 9.46 14.516

Ground Floor 5 9.46 19.316

Mezzanine 5 9.46 19.316

Podiums 2 9.46 14.516

First Group 2.5 9.46 15.316

Second Group 2.5 9.46 15.316

Third Group 2.5 9.46 15.316

Fourth Group 2.5 9.46 15.316

Fifth Group 2.5 9.46 15.316

Sixth Group 2.5 9.46 15.316

Seventh Group 2.5 9.46 15.316

Eighth Group 2.5 9.46 15.316

Roof Deck Floor 2.5 9.46 15.316

Page 14: Structural & Geotechnical Design of 50 Storey Tower

COLUMNS DIMENSIONS

Column Group Dimensions (m)

1 x 0.4

0.8 x 0.4

2 x 1.5

2.5 x 2.5

2 x 2

2.5 x 2

1 x 1

ETABS 2013 Software

12/28/2017 14

Page 15: Structural & Geotechnical Design of 50 Storey Tower

ETABS MODELING

15 12/28/2017

Page 16: Structural & Geotechnical Design of 50 Storey Tower

o 3D model

ETABS 2013 Software

12/28/2017

ETABS MODELING

16

Page 17: Structural & Geotechnical Design of 50 Storey Tower

o Typical Floor Plan (Columns)

ETABS 2013 Software

12/28/2017

ETABS MODELING (CONTINUOUS)

17

Page 18: Structural & Geotechnical Design of 50 Storey Tower

o Typical Floor Plan

(Shear Walls)

ETABS 2013 Software

12/28/2017

ETABS MODELING (CONTINUOUS)

18

Page 19: Structural & Geotechnical Design of 50 Storey Tower

o Typical Super Structure Floor

Plan (Columns).

ETABS 2013 Software

12/28/2017

ETABS MODELING (CONTINUOUS)

19

Page 20: Structural & Geotechnical Design of 50 Storey Tower

o Typical Super Structure Floor

Plan (Shear walls).

ETABS 2013 Software

12/28/2017

ETABS MODELING (CONTINUOUS)

20

Page 21: Structural & Geotechnical Design of 50 Storey Tower

ETABS ANALYSIS

21 12/28/2017

Page 22: Structural & Geotechnical Design of 50 Storey Tower

ETABS ANALYSIS

Structural members sizes are accepted!

Actual drift in X & Y is

less than the allowable

limit.

Actual deflection is less than the

allowable deflection.

3D model created using

ETABS.

12/28/2017

According to SBC

22

Page 23: Structural & Geotechnical Design of 50 Storey Tower

ETABS

ANALYSIS (CONTINUOUS)

o Load Combination:

DL + LL

o Allowable deflection = 25mm

per floor (according to SBC).

ETABS 2013 Software

12/28/2017 23

Page 24: Structural & Geotechnical Design of 50 Storey Tower

o Load Combination:

WindX + DL

o Allowable drift = 1930mm

(according to SBC).

ETABS 2013 Software

12/28/2017

ETABS

ANALYSIS (CONTINUOUS)

24

Page 25: Structural & Geotechnical Design of 50 Storey Tower

o Load Combination:

WindY + DL

o Allowable drift = 1930mm

(according to SBC).

ETABS 2013 Software

12/28/2017

ETABS

ANALYSIS (CONTINUOUS)

25

Page 26: Structural & Geotechnical Design of 50 Storey Tower

ETABS 2013 Software

o Load Combination:

eqX + DL

o Allowable drift = 1930mm

(according to SBC).

12/28/2017

ETABS

ANALYSIS (CONTINUOUS)

26

Page 27: Structural & Geotechnical Design of 50 Storey Tower

ETABS 2013 Software

o Load Combination:

eqY + DL

o Allowable drift = 1930mm

(according to SBC).

12/28/2017

ETABS

ANALYSIS (CONTINUOUS)

27

Page 28: Structural & Geotechnical Design of 50 Storey Tower

ETABS 2013 Software

o Maximum moment at Sub-Basement

12/28/2017

ETABS

ANALYSIS (CONTINUOUS)

28

Page 29: Structural & Geotechnical Design of 50 Storey Tower

12/28/2017 29

REINFORCEMENT DETAILS

Page 30: Structural & Geotechnical Design of 50 Storey Tower

REINFORCEMENT DETAILS

(COLUMNS)

AUTOCAD 2016 Software

12/28/2017

30

Column

Group

# of bars Diameter

(mm)

Spacing

(mm)

2.5 x 2.5 94 57 43

2 x 2 80 57 40

Page 31: Structural & Geotechnical Design of 50 Storey Tower

AUTOCAD 2016 Software

12/28/2017

31

REINFORCEMENT DETAILS

(COLUMNS)

Column

Group

# of bars Diameter

(mm)

Spacing

(mm)

2 x 1.5 64 57 60

1 x 1 48 32 43

Page 32: Structural & Geotechnical Design of 50 Storey Tower

AUTOCAD 2016 Software

12/28/2017

32

REINFORCEMENT DETAILS

(COLUMNS)

Column

Group

# of bars Diameter

(mm)

Spacing

(mm)

2.5 x 2 110 57 29

0.8 x 0.4 20 32 80

Page 33: Structural & Geotechnical Design of 50 Storey Tower

12/28/2017

AUTOCAD 2016 Software

REINFORCEMENT DETAILS (SLAB)

33

Page 34: Structural & Geotechnical Design of 50 Storey Tower

12/28/2017

AUTOCAD 2016 Software

REINFORCEMENT DETAILS

(SHEAR WALLS)

34

Page 35: Structural & Geotechnical Design of 50 Storey Tower

GEOTECHNICAL DESIGN

35 12/28/2017

Page 36: Structural & Geotechnical Design of 50 Storey Tower

o Soil profile

Geotechnical Design

12/28/2017 36

Page 37: Structural & Geotechnical Design of 50 Storey Tower

o Characteristics:

- Driven Piles.

- Bored Piles.

Foundations: Section A Section B

Selected Foundation

system:

Piled Mat Foundation Piled Mat Foundation

Factor of safety: 3 3

Mat Foundation

Thickness

3.4m. 1.66m.

Net bearing capacity: qu(net)=31,795 kN/m2 .

qall(net)=10,598 kN/m2 .

qu(net)=32,132 kN/m2 .

qall(net)=10,710 kN/m2

Geotechnical Design (Continues)

12/28/2017 37

Page 38: Structural & Geotechnical Design of 50 Storey Tower

AUTOCAD 2016 Software

o Mat Foundation With Applied

Loads(DL+LL)

12/28/2017

Geotechnical Design (Continues)

38

Page 39: Structural & Geotechnical Design of 50 Storey Tower

AUTOCAD 2016 Software

o Design of Mat foundation:

- Strip Method

12/28/2017

Geotechnical Design (Continues)

39

Page 40: Structural & Geotechnical Design of 50 Storey Tower

o Design of Mat foundation:

- Steel Rebar.

Foundation Top Steel Bottom Steel

Section A @D=12mm, #=4 bars. @D=24mm, #=11 bars.

Section B @D=10mm, #=4 bars. @D=18mm, #=9 bars.

12/28/2017

Geotechnical Design (Continues)

40

Page 41: Structural & Geotechnical Design of 50 Storey Tower

o Piles Design.

Foundations Section A Section B

Pile Diameter(m) 0.3 0.3

Qall(kN) 2054.9 1356.2

Number of piles 238 266

12/28/2017

Geotechnical Design (Continues)

41

Page 42: Structural & Geotechnical Design of 50 Storey Tower

o Group of Piles

12/28/2017

Geotechnical Design (Continues)

42

Page 43: Structural & Geotechnical Design of 50 Storey Tower

o Piles Spacing and

Dimensions.

AUTOCAD 2016 Software

12/28/2017

Geotechnical Design (Continues)

43

Page 44: Structural & Geotechnical Design of 50 Storey Tower

12/28/2017 44

COST ESTIMATION

Page 45: Structural & Geotechnical Design of 50 Storey Tower

COST ESTIMATION

45 12/28/2017

Based on the construction prices for one unit m2 in the region of Dammam city for the period 2017/2018

Floor Type Unit Price (m2)

Floor Area (m2)

Total Area (m2)

Cost (SAR)

Super Structure 3000 1840 73600 220,800,000

Ground Floor & Mezzanine

4500 3720 7440 33,480,000

Podiums 2500 3720 29760 74,400,000

Total Cost 328,680,000

Page 46: Structural & Geotechnical Design of 50 Storey Tower

ACKNOWLEDGMENT

12/28/2017 46

Page 47: Structural & Geotechnical Design of 50 Storey Tower

CONCLUSION

12/28/2017

oChoosing an adequate structural system.

oPreliminary design of structural members.

oModeling using ETABS software for design & analysis.

oGeotechnical design of the foundation system.

47

Page 48: Structural & Geotechnical Design of 50 Storey Tower

REFERENCES

12/28/2017 48

o ACI 318-11 Code : American Concrete Institute.

o SBC (301) : Saudi Building Code.

o SBC(303): Saudi Building Code.

o International Building Code 2009.

o Principle of Foundation Engineering BRAJA DAS (7th edition).

o Arabtech Jardaneh.

o Abdulrahman Al-Otaishan Group.

Page 49: Structural & Geotechnical Design of 50 Storey Tower

AUTOCAD 2016 Software

12/28/2017 49