User Manual
Original Instructions
Stratix 2000 Ethernet Unmanaged SwitchesCatalog Numbers 1783-US5T, 1783-US5TG, 1783-US4T1F, 1783-US4T1H, 1783-US8T, 1783-US6T2F, 1783-US6T2H, 1783-US7T1F, 1783-US7T1H, 1783-US6T2TG2F, 1783-US6T2TG2H, 1783-US8TG2GX, 1783-US16T, 1783-US16T2S
Topic Page
Broadcast Storm Protection 3
DIP Switches 4
Status Indicators 4
Additional Resources 10
Stratix 2000 Ethernet Unmanaged Switches
Important User Information
Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.
Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice.
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited
Throughout this manual, when necessary, we use notes to make you aware of safety considerations.
Labels may also be on or inside the equipment to provide specific precautions.
WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous
environment, which may lead to personal injury or death, property damage, or economic loss.
ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property
damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence.
IMPORTANT Identifies information that is critical for successful application and understanding of the product.
SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous
voltage may be present.
BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may
reach dangerous temperatures.
ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to
potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL
Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE).
2 Rockwell Automation Publication 1783-UM011B-EN-P - September 2017
Stratix 2000 Ethernet Unmanaged Switches
Broadcast Storm ProtectionA broadcast storm occurs when a network is overwhelmed by continuous multicast or broadcast traffic typically caused by loops in the network. A severe broadcast storm can block all other network traffic. Stratix® 2000 switches provide protection against broadcast storms. When the broadcast storm protection feature is enabled, the switch drops incoming broadcast traffic if the traffic exceeds a certain threshold.
Stratix 2000 switches use two methods to determine the threshold for incoming broadcast traffic, depending on the switch catalog number:
• Packet-based threshold—The switch counts the number of broadcast packets received within a time cycle. Once the number of broadcast packets reaches the maximum number of packets in the time cycle, the port drops any excess broadcast packets. For threshold values based on packet number, see Table 1.
• Rate-based threshold—The switch tracks the bandwidth of each port based on a maximum bit rate. Once a port reaches the maximum bit rate, the port drops any excess broadcast packets. For threshold values based on rate, see Table 2.
You can enable or disable broadcast storm protection by using DIP switch SW1 on the top panel of the switch:
• To enable the feature, set SW1 to the On position and restart the switch. • To disable the feature, set SW1 to the Off position. By default, the feature is disabled.
Table 1 - Packet-based Thresholds
Cat. No. Broadcast Storm Threshold (Packets per Second)
1783-US5T 20 pps for 10 Mbps per port; 200 pps for 100 Mbps per port
1783-US4T1F 20 pps for 10 Mbps per port; 200 pps for 100 Mbps per port
1783-US4T1H 20 pps for 10 Mbps per port; 200 pps for 100 Mbps per port
1783-US8T 20 pps for 10 Mbps per port; 200 pps for 100 Mbps per port
1783-US6T2F 20 pps for 10 Mbps per port; 200 pps for 100 Mbps per port
1783-US6T2H 20 pps for 10 Mbps per port; 200 pps for 100 Mbps per port
1783-US7T1F 20 pps for 10 Mbps per port; 200 pps for 100 Mbps per port
1783-US7T1H 20 pps for 10 Mbps per port; 200 pps for 100 Mbps per port
1783-US6T2TG2F 128 pps for 10/100/1000 Mbps
1783-US6T2TG2H 128 pps for 10/100/1000 Mbps
1783-US8TG2GX 128 pps for 10/100/1000 Mbps
Table 2 - Rate-based Thresholds
Cat. No. Broadcast Storm Threshold
1783-US16T 10 Mbps per port
1783-US16T2S 10 Mbps per port
1783-US5TG 25 Mbps per port
Rockwell Automation Publication 1783-UM011B-EN-P - September 2017 3
Stratix 2000 Ethernet Unmanaged Switches
DIP SwitchesThere are two DIP switches on the top panel of the switches. Each switch has On and Off states.
The function of the DIP switches varies by catalog number.
Status IndicatorsThe status indicators on the switches indicate the following:
• Status of each power supply• Status of port speed• Status of network connection or activity
The function of the status indicators varies by catalog number:
• 5- and 8-port Fast Ethernet Switches on page 5• 10-port Fast Ethernet Switches on page 6• 16- and 18-port Fast Ethernet Switches on page 7• 5- and 10-port Gigabit Ethernet Switches on page 8
IMPORTANT To activate DIP switch settings, you must restart the switch.
Cat. No. DIP Switch Status Description Default
1783-US5T, 1783-US4T1F, 1783-US4T1H, 1783-US8T, 1783-US6T2F, 1783-US6T2H, 1783-US7T1F, 1783-US7T1H, 1783-US16T, 1783-US16T2S
SW1On Enables broadcast storm protection.
OffOff Disables broadcast storm protection.
SW2 Reserved Off
1783-US6T2TG2F
1783-US6T2TG2H
SW1On Enables broadcast storm protection.
OffOff Disables broadcast storm protection.
SW2On
Sets the SFP fiber port speed to 100 Mbps (100Base-FX).
SW2 must remain in the On position. On
Off Reserved
1783-US5TG
1783-US8TG2GX
SW1On Enables broadcast storm protection.
OffOff Disables broadcast storm protection.
SW2On
Transmits jumbo frames up to 10 KB on the 1783-US5TG switch and up to 9.6 KB on the 1783-US8TG2GX switch. Off
Off Drops jumbo frames.
32695-M
SW2
SW1
OFF
ON
DIP Switches
4 Rockwell Automation Publication 1783-UM011B-EN-P - September 2017
Stratix 2000 Ethernet Unmanaged Switches
5- and 8-port Fast Ethernet SwitchesThese illustrations show the status indicators on the 1783-US5T, 1783-US6T2F, and 1783-US7T1F switches. The status indicators on the 1783-US4T1F, 1783-US4T1H, 1783-US8T, 1783-US6T2H, 1783-US7T1H switches function the same as these switches.
Indicator Status Description
PWR1On PWR1 is connected and operates normally.
Off PWR1is not connected or operates abnormally.
PWR2On PWR2 is connected and operates normally.
Off PWR2 is not connected or operates abnormally.
RJ45 port connection (green)
On The port has an operating network connection.
Blinking(1)
(1) For blink rate, see page 9.
There is network activity on the port.
Off The port has no network connection.
RJ45 port speed (yellow)On The port is operating at 100 Mbps (100Base-TX).
Off The port is operating at 10 Mbps, or the port has no network connection.
SFP fiber port status (green)
On The port has an operating network connection.
Blinking(1) There is network activity on the port.
Off The port has no network connection.
1
2
3
4
5
2000R
1783-US5T
32687-M
3
5
7
4
6
8
2000R
1783-US6T2F
32688-M
1 2
3
5
7
4
6
8
1 2
2000R
1783-US7T1F
32689-M
RJ45 Port
Speed (Yellow)
RJ45 Port
Connection (Green)
PWR1 (Power 1)
PWR2 (Power 2)
PWR1 (Power 1)
PWR2 (Power 2)
PWR1 (Power 1)
PWR2 (Power 2)
RJ45 Port
Speed (Yellow)
RJ45 Port
Connection (Green)
SFP Fiber Port Status
RJ45 Port
Speed (Yellow)
RJ45 Port
Connection (Green)
Rockwell Automation Publication 1783-UM011B-EN-P - September 2017 5
Stratix 2000 Ethernet Unmanaged Switches
10-port Fast Ethernet SwitchesThis illustration shows the status indicators on the 1783-US6T2TG2F and 1783-US6T2TG2H switches.
Indicator Status Description
PWR1On PWR1 is connected and operates normally.
Off PWR1is not connected or operates abnormally.
PWR2On PWR2 is connected and operates normally.
Off PWR2 is not connected or operates abnormally.
RJ45 Fast Ethernet port connection (green)
On The port has an operating network connection.
Blinking There is network activity on the port.
Off The port has no network connection. For the blink rate, see page 9.
RJ45 Fast Ethernet port speed (yellow)On The port is operating at 100 Mbps (100Base-TX).
Off The port is operating at 10 Mbps, or the port has no network connection.
RJ45 Gigabit Ethernet port connection (green)
On The port has an operating network connection.
Blinking There is network activity on the port. For the blink rate, see page 9.
Off The port has no network connection.
RJ45 Gigabit Ethernet port speed (yellow)On The port is operating at 1000 Mbps (1000Base-TX).
Off The port is operating at 10/100 Mbps (10/100Base-T(X)), or the port has no network connection.
SFP fiber port connection
On The port has an operating network connection.
Blinking There is network activity on the port. For the blink rate, see page 9.
Off The port has no network connection.
SFP fiber port speed (yellow)
On The port is operating at 1000 Mbps (1000Base-X).
OffThe port is operating at 100 Mbps (100Base-FX), or the port has no network connection.
IMPORTANT: By default, the switch operates at 100 Mbps and the SFP fiber port speed indicator is Off.
2000
G1
3
5
7
G2
4
6
8
R
1783-US6T2TG2F
1 2
RJ45 Fast Ethernet Port Speed (Yellow)
RJ45 Fast Ethernet Port Connection (Green)
PWR1 (Power 1)
PWR2 (Power 2)
RJ45 Gigabit Ethernet Port Speed (Yellow)
RJ45 Gigabit Ethernet Port Connection (Green)
SFP Fiber Port 1 Speed (Yellow)
SFP Fiber Port 2 Speed (Yellow)SFP Fiber Port 1Connection (Green)
SFP Fiber Port 2 Connection (Green)
The top two arrow-shaped status indicators apply to SFP slot 1.
The bottom two arrow-shaped status indicators apply to SFP slot 2.
6 Rockwell Automation Publication 1783-UM011B-EN-P - September 2017
Stratix 2000 Ethernet Unmanaged Switches
16- and 18-port Fast Ethernet SwitchesThese illustrations show the status indicators on the 1783-US16T and 1783-US16T2S switches.
Indicator Status Description
PWR1On PWR1 is connected and operates normally.
Off PWR1is not connected or operates abnormally.
PWR2On PWR2 is connected and operates normally.
Off PWR2 is not connected or operates abnormally.
RJ45 port connection (green)
On The port has an operating network connection.
Blinking(2)
(2) For blink rate, see page 9.
There is network activity on the port.
Off The port has no network connection.
RJ45 port speed (yellow)On The port is operating at 100 Mbps (100Base-TX).
Off The port is operating at 10 Mbps, or the port has no network connection.
SFP slot status(1)
(1) Available only on 1783-US16T2S switches.
On The port has an operating network connection.
Blinking(2) There is network activity on the port.
Off The port has no network connection.
2000
1783-US16T
1
3
2
4
5
7
6
8
9
11
10
12
13
15
14
16
R
32693-M
2000
1783-US16T2S
3
1 2
5
4
6
7
9
8
10
11
13
12
14
15
17
15
18
R
32694-M
RJ45 Port Speed (Yellow)
RJ45 Port Connection (Green)
PWR1 (Power 1)
PWR2 (Power 2)
PWR1 (Power 1)
PWR2 (Power 2)
RJ45 Port Speed (Yellow)
RJ45 Port Connection (Green)
SFP Slot Status
Rockwell Automation Publication 1783-UM011B-EN-P - September 2017 7
Stratix 2000 Ethernet Unmanaged Switches
5- and 10-port Gigabit Ethernet SwitchesThese illustrations show the status indicators on the 1783-US5TG and 1783-US8TG2GX switches.
Indicator Status Description
PWR1On PWR1 is connected and operates normally.
Off PWR1is not connected or operates abnormally.
PWR2On PWR2 is connected and operates normally.
Off PWR2 is not connected or operates abnormally.
RJ45 port connection (green)
On The port has an operating network connection.
Blinking There is network activity on the port.
Off The port has no network connection.
RJ45 port speed (yellow)On The port is operating at 1000 Mbps (1000Base-TX).
Off The port is operating at 10/100 Mbps (10/100Base-TX), or the port has no network connection.
SFP slot speed (yellow)(1)
(1) Available only on 1783-US8TG2GX switches.
On The port is operating at 1000 Mbps (1000Base-X).
Off The port is operating at 100 Mbps (100Base-FX), or the port has no network connection.
SFP slot connection (green)(1)
On The port has an operating network connection.
Blinking There is network activity on the port.
Off The port has no network connection.
2000R
1783-US5TG
32687-M
G5
G4
G3
G2
G1
PWR1 (Power 1)
PWR2 (Power 2)
RJ45 Port Speed (Yellow)
RJ45 Port Connection (Green)
2000
G3 G4
G5 G6
G7 G8
G9 G10
R
1783-US8TG2GX
32692-M
1 2SFP Slot 1 Speed (Yellow)
SFP Slot 2 Speed (Yellow)SFP Slot 1 Connection (Green)
SFP Slot 2 Connection (Green)
The top two arrow-shaped status indicators apply to SFP slot 1.
The bottom two arrow-shaped status indicators apply to SFP slot 2.
PWR1 (Power 1)
PWR2 (Power 2)
RJ45 Port Speed (Yellow)
RJ45 Port Connection (Green)
8 Rockwell Automation Publication 1783-UM011B-EN-P - September 2017
Stratix 2000 Ethernet Unmanaged Switches
Status Indicator Blink RateA port status indicator blinks to indicate network activity on the port. The rate at which a status indicator blinks varies by catalog number.
Cat. No. Rate
1783-US5T 105 ms
1783-US5TG 84 ms
1783-US4T1F 105 ms
1783-US4T1H 105 ms
1783-US8T 105 ms
1783-US6T2F 105 ms
1783-US6T2H 105 ms
1783-US7T1F 105 ms
1783-US7T1H 105 ms
1783-US6T2TG2F 100 ms
1783-US6T2TG2H 100 ms
1783-US8TG2GX 100 ms
1783-US16T 42 ms
1783-US16T2S 42 ms
Rockwell Automation Publication 1783-UM011B-EN-P - September 2017 9
Additional ResourcesThese documents contain additional information concerning related products from Rockwell Automation.
You can view or download publications at http://www.rockwellautomation.com/global/literature-library/overview.page. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
Rockwell Automation SupportUse the following resources to access support information.
Technical Support Center Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates.
https://rockwellautomation.custhelp.com/
Local Technical Support Phone Numbers
Locate the phone number for your country.http://www.rockwellautomation.com/global/support/get-support-now.page
Direct Dial CodesFind the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer.
http://www.rockwellautomation.com/global/support/direct-dial.page
Literature Library Installation Instructions, Manuals, Brochures, and Technical Data.
http://www.rockwellautomation.com/global/literature-library/overview.page
Product Compatibility and Download Center (PCDC)
Get help determining how products interact, check features and capabilities, and find associated firmware.
http://www.rockwellautomation.com/global/support/pcdc.page
Resource Description
Stratix 2000 Ethernet Unmanaged Switches Installation Instructions, publication 1783-IN003
Describes how to install Stratix 2000 switches.
Stratix Ethernet Device Specifications Technical Data, publication 1783-TD001 Provides specification information for Stratix 2000 switches and other Ethernet devices.
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing a Rockwell Automation industrial system.
Product Certifications website,
http://www.rockwellautomation.com/global/certification/overview.page Provides declarations of conformity, certificates, and other certification details.
Allen-Bradley, Rockwell Automation, Rockwell Software, and Stratix are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Rockwell Automation maintains current product environmental information on its website at
http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.
Publication 1783-UM011B-EN-P - September 2017Supersedes Publication 1783-UM011A-EN-P - April 2017 Copyright © 2017 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.