Upload
ceana
View
103
Download
0
Tags:
Embed Size (px)
DESCRIPTION
EMC MANAGEMENT INTEGRATION FOR MICROSOFT PRIVATE CLOUD EMC Symmetrix VMAX, EMC VNX, EMC Storage Integrator (ESI) for Windows Suite, Microsoft System Center 2012. Application to Infrastructure management and monitoring Optimized storage for elastic infrastructures - PowerPoint PPT Presentation
Citation preview
1© Copyright 2012 EMC Corporation. All rights reserved.
EMC MANAGEMENT INTEGRATION FOR MICROSOFT PRIVATE CLOUDEMC Symmetrix VMAX, EMC VNX, EMC Storage Integrator (ESI) for Windows Suite, Microsoft System Center 2012
Strategic Solutions Engineering (SSE)EMC Solutions Group (ESG)
Michael Morris – Principal Solutions EngineerIke Aikemu –Solutions EngineerAlex Bowers – Senior Solutions Engineer
• Application to Infrastructure management and monitoring• Optimized storage for elastic infrastructures• Automated storage provisioning
2© Copyright 2012 EMC Corporation. All rights reserved.
EMC Proven Solutions Solution overview
– Application requirements– System Management– VNX storage pool allocation
Results– VNX in-tier rebalance– Application results– System Center 2012 SP1
▪ SCOM, SCVMM, SCO
Summary– Solution pack
Q&A
Agenda
3© Copyright 2012 EMC Corporation. All rights reserved.
EMC Proven Solutions Approach
Capture and
defineTest and validate Document Publish
Singapore Shanghai, China
Cork, Ireland
Hopkinton, MA
Santa Clara, CA
Vienna, Austria
1 2 3 4Re
quire
men
ts
…real world Solutions
4© Copyright 2012 EMC Corporation. All rights reserved.
Solution Overview
5© Copyright 2012 EMC Corporation. All rights reserved.
Solution Purpose
Microsoft System Center 2012 SP1 VMware ESXi and Windows Server Hyper-V 2012
– Multi-hypervisor environment EMC Symmetrix VMAX 10K, EMC VNX5700
– Multi-array environment EMC Storage Integrator (ESI) for Windows Suite Mixed application workloads
This objective of this solution is to demonstrate EMC’s integration with Microsoft System Center 2012 SP1, which allows support for Windows Server 2012 for management of a Microsoft private cloud environments.
6© Copyright 2012 EMC Corporation. All rights reserved.
Solution Overview System Center 2012 SP1
– Provides centralized management– Windows Server 2012 support
ESI Management Packs for SCOM– Monitor health & performance
EMC SMI-S provider– Allows SCVMM 2012 SP1 to easily manage and
provision EMC storage ESI PowerShell
– Allows automated provisioning and allocation of EMC storage with SCO 2012 SP1
SCVMM 2012 SP1 – provides simplified and centralized
management of both ESXi and Hyper-V
VNX Automatic in-tier rebalance FAST VP policies for workload co-location
7© Copyright 2012 EMC Corporation. All rights reserved.
Application Item Quantity/Type/Size
Exchange
Mailbox Count 5,000Mailbox Size 2 GB IOPS (per mailbox) 0.10 IOPS Availability DAG, 2 Copies Disk type, number, and RAID type 48 * 2TB NL-SAS, RAID 1/0
DB LUN size per server 1700GB * 20 (10 DB LUNs per server)LOG LUN size per server 100GB * 20 (10 log LUNs per server)
SharePoint
Total User Count 5,000
Usage Profile (%browse/%search/%modify/%download) 60/10/10/20
User Concurrency 10%Total Data 4.4 TBTotal Site Collections (Content DBs) Count 5Sites per Site Collection 10 - 100Document Size Range 200 kb – 2 MBDisk type, number, and RAID type VNX FAST VP enabled Storage Pool
SQL Server
SQL – IOPs (Disk Transfers/sec) Try to achieve 5,000 IOPS SQL Server Instances 1Workload type TPC-E Like SQL Server Production VM 16 vCPU / 64GB SQL User Databases 1 User DB – 500GB
Disk type, number, and RAID type VNX FAST VP enabled Storage Pool
Application requirements
..workload profiles
8© Copyright 2012 EMC Corporation. All rights reserved.
Hyper-V cluster ESXi cluster
VNX5700 VMAX 10K
SCOM 2012
ESI
SCVMM 2012
Agent(VM)Agent
ESI ServiceESI Service
System Management
…how it all works
SCO 2012
SMI-S
9© Copyright 2012 EMC Corporation. All rights reserved.
18 Disks (0-17)
SAS (Pool 0 -Tier 1)8+18+1 4+1
1 2 3 40
FLASH DRIVES (Pool 0 – Tier 0)
4+1 1mirror 1mirror 1 mirror
2.0
1.0
1 2 3 4 5 6 70
NL-SAS(Pool 0 – Tier 2)
6+2
0.1
18 Disks (0-17)
SAS (Pool 0 -Tier 1)8+18+1 4+1
3.0
4 5 6 7
FAST Cache(Array Resource)
1+1
0.0
1+1
VNX Storage Pool Allocation
Application consolidation …for SQL & SharePoint!
…available if required! …but not required in this solution!
10© Copyright 2012 EMC Corporation. All rights reserved.
Results
11© Copyright 2012 EMC Corporation. All rights reserved.
VNX in-tier rebalance - Physical Disk Utilization (%)
…in-tier rebalance following storage pool expansion
12© Copyright 2012 EMC Corporation. All rights reserved.
VNX Physical Disk Utilization (%)
…disk utilization across all configurations
Disk Configurations• Baseline configuration: 18 * SAS (R5 *, 8+1) + 8 * NL-SAS (R6, 6+2)• with additional SAS drives (18 * drives added): 36 * SAS (R5, 8+1) + 8 * NL-
SAS (R6, 6+2)• with Flash drives 36 * SAS (R5, 8+1) + 8 * NL-SAS (R6, 6+2) + 5 * Flash
(R5, 4+1)
13© Copyright 2012 EMC Corporation. All rights reserved.
SQL Server results
…SQL Server workload hosted on VNX
Results• Over x 4 increase in IOPs between base and final configuration• Latency reduced from 23ms Read / 13ms Write to 2ms Read / 2ms Write
VNX storage pool expansion and enabling FAST VP
14© Copyright 2012 EMC Corporation. All rights reserved.
SharePoint & Exchange results
…SharePoint workload on VNX, Exchange on VMAX 10K
SharePoint – Medium Farm• Browse Modify, Search and Download test times
– were completed in less than 3 seconds• Passed tests/sec were constant, averaging 29.83
– which equates to 17,900 users @ 10% concurrency
Exchange – 5,000 Users, 2 * Copies• Information Store Avg. Latency was 1.9ms
(<10ms)• I/O Database Reads Avg. Latency was 7.35ms
(<20ms)• I/O Database Writes Avg. Latency was 3.5ms
(<20ms)• I/O Log Writes Avg. Latency was 5.5ms (10ms)
15© Copyright 2012 EMC Corporation. All rights reserved.
VNX Physical Disk Utilization (%)
…healthy view of storage pool in Unisphere
Disk Utilizations across three tier storage pool• Flash (77%), SAS (25%) …hosting OS, SQL Data & SharePoint LUNs (minus
contents DBs)• NL-SAS (38%) - hosting only SharePoint content database LUN pinned to
lowest tier
16© Copyright 2012 EMC Corporation. All rights reserved.
LUN Names Tier allocation %SSD SAS NL-SAS
LUN_1_Admin_VMs 1.05 98.95 LUN_2_App_VMs 0.7 99.3 LUN_3_SQL_Data 48.14 51.86 LUN_4_TempDB_And_DB_Logs 1.29 98.71 LUN_5_SP_ContentDatabases 100 LUN_6_SP_ContentDatabases_Logs 0.2 99.8LUN_7_Config_DB 0.79 99.21 LUN_8_Search_TempDB 0.53 99.47 LUN_9_SP_Search_TempDB_Logs 1.74 98.26 LUN_10_SP_Query_Index 0.19 99.81
VNX LUN tier allocation
…following FAST VP relocation window
17© Copyright 2012 EMC Corporation. All rights reserved.
EMC Integration
18© Copyright 2012 EMC Corporation. All rights reserved.
SCOM – Monitor and Report
…single console view
…in this solution• EMC Storage system monitor
• ESI management packs for SCOM • Reporting
• Storage• Host utilization• Chargeback
• Application monitor• Exchange• SQL• SharePoint
• OS health monitor• CPU• Memory• Disk volume
19© Copyright 2012 EMC Corporation. All rights reserved.
SCOM- Health Monitor for EMC Storage
…SCOM storage topology view
Overall topology view of storage system in SCOM
VNX5700VMAX 10K
• Import and configure ESI Management Packs for SCOM
• Health monitor via ESI Service and RESTFul API• Storage system topology
• Array health• Space utilization• Alerts
20© Copyright 2012 EMC Corporation. All rights reserved.
ESI Management Packs for SCOM
…monitoring components with SCOM
Storage Group Overall Health
Monitored Components• ESI Service• Logical Components
– Storage Pools– Snapshot Volume– Storage Group
• Physical Components– CPU Module– Disk Drive– Enclosure– Network Switch– Memory Module
21© Copyright 2012 EMC Corporation. All rights reserved.
SCVMM – Cloud Management
…manage both Hyper-V and ESXi
…in this solution• Storage Management and provisioning via EMC SMI-S
provider• EMC VNX5700• EMC VMAX 10K
• Host Management• Hyper-V• ESXi (via VMware vCenter)
• VM Provisioning
22© Copyright 2012 EMC Corporation. All rights reserved.
SCVMM – EMC Storage Management
…storage management
Managing both VNX5700 and VMAX 10K
Manage EMC storage system via EMC SMI-S provider• Discover VNX and VMAX• Configure storage pools• Create LUNs
23© Copyright 2012 EMC Corporation. All rights reserved.
SCO – Orchestrator RunBook Designer
…RunBook Designer
…no activities of LUN creation in SCVMM IP
…Runbook – a series of activities
Workflow management1. Create VM via
SCVMM IP (Integration Pack)
2. Create LUN with ESIPS
3. Add Disk to VM…
24© Copyright 2012 EMC Corporation. All rights reserved.
SCO – ESIPowerShell toolkit
…ESIPowerShell cmdlets
Example activity Run .Net script
Automatically created based on user input, which:• Provisions storage• Allocates storage to
VM
25© Copyright 2012 EMC Corporation. All rights reserved.
Hyper-V cluster ESXi cluster
VNX5700 VMAX 10K
SCOM 2012
ESI
SCVMM 2012
Agent(VM)Agent
ESI ServiceESI Service
System Management
…how it all works
SCO 2012
SMI-S
26© Copyright 2012 EMC Corporation. All rights reserved.
Summary
27© Copyright 2012 EMC Corporation. All rights reserved.
SummaryThis solution highlights the close integration of ESI for Windows Suite with Microsoft System Center 2012 SP1, which allows administrators to control application and EMC storage infrastructure throughout the data center. This includes multi-hypervisor and multi-array environments.
ESI Management Packs for SCOM monitor EMC storage systems. EMC SMI-S Provider allows storage management with SCVMM ESI PowerShell allows automated provisioning of EMC storage SCO provides workflow management SCVMM manages both ESXi and Hyper-V VNX automatic in-tier rebalance, following storage-pool tier
expansion FAST VP policies allow co-location of multiple workloads
28© Copyright 2012 EMC Corporation. All rights reserved.
Solution Pack Collateral …ECN/YouTubeInformation Link
Whitepaper location's http://www.emc.com/collateral/whitepaper/h11228-management-integration-cloud-wp.pdf
Technical Presentation …available soonSolution Webcast …19th February 2012Tech Articles: Everything Microsoft @ EMCEMC MANAGEMENT INTEGRATION FOR MICROSOFT PRIVATE CLOUD - Solution homepage https://community.emc.com/docs/DOC-21431
System Center management with ESI and SMI-S https://community.emc.com/docs/DOC-21432Monitoring EMC storage using SCOM 2012 SP1 with ESI Management Packs https://community.emc.com/docs/DOC-21433Application monitoring with SCOM Management Packs https://community.emc.com/docs/DOC-21434Chargeback with SCOM SP1 https://community.emc.com/docs/DOC-21435SCVMM 2012 SP1 support for ESXi https://community.emc.com/docs/DOC-21436EMC SMI-S provider for SCVMM 2012 SP1 allows EMC storage discovery https://community.emc.com/docs/DOC-21437SCO 2012 SP1 and ESI PowerShell https://community.emc.com/docs/DOC-21438Co-location of SQL Server and SharePoint volumes in VNX storage pool https://community.emc.com/docs/DOC-21439Videos: Everything Microsoft @ EMC / YouTube: EMCProvenSolutions
Adding an EMC VMAX and creating a LUN in Microsoft SCVMM 2012 SP1 • https://community.emc.com/videos/4949• http://youtu.be/ts_vQlMuqTk
Creating and adding an EMC LUN to a host in Microsoft SCVMM 2012 SP1 • https://community.emc.com/videos/4950• http://youtu.be/sZw66BoeMVY
Automating the creation of a virtual machine and adding an EMC LUN in Microsoft SCO 2012 SP1
• https://community.emc.com/videos/4951• http://youtu.be/g3inYLpSYL8
ESI for Windows Suite integration with Microsoft SCOM 2012 SP1 for monitoring EMC arrays
• https://community.emc.com/videos/4952 • http://youtu.be/kdzDt9a5d1M
…collateral ECN & YouTube channel: EMCProvenSolutions
29© Copyright 2012 EMC Corporation. All rights reserved.
Q&AECN solution homepage: https://community.emc.com/docs/DOC-21431
WP: http://www.emc.com/collateral/whitepaper/h11228-management-integration-cloud-wp.pdf YouTube channel: http://www.youtube.com/user/EMCProvenSolutions