28
Sales Manual B.Braun Space Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Chapter 5.2 Overview Variants in Application Safety features Therapy diversity Anesthesia Further Options ter 5.2: B. Braun SpaceControl – Product details

Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2 Overview Variants in Application Safety features

Embed Size (px)

Citation preview

Page 1: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 1

Chapter 5.2

Overview

Variants in Application

Safety features

Therapy diversity

Anesthesia

Further Options

Chapter 5.2: B. Braun SpaceControl – Product details

Page 2: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 2

SpaceControl is making the pump universal…

SpaceControl is an expanded programming station for B. Braun

Space Pumps.

SpaceControl increases the features of a single pump acc. to the therapeutic needs in special therapies.

SpaceControl offers a unique user interface structure in the field of infusion technique.

The colored touch-screen display enables all users to program all Space Pumps via its excellently ergonomic handling structure.

With the integrated barcode software all relevant therapy data can be transmitted into the Space Pumps in a very safe and cost-efficient way.

SpaceControl makes it possible that one type of pump can be used in all areas of the hospital and for all necessary forms of therapies.

Page 3: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 3

Expanded Programming Station Connection to pump

Protected display through slide-in

technology for safe transports

Barcode reader socket

Status LED and Infrared interface

Press here, then

pull to open

Optional input for central

pressure measurem

ent

Big coloured touch screen display for a

simple and easy programming of a single pump

Pen

SpaceControl – General Overview

Page 4: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 4

SpaceStation – How does it work?

SpaceControl only can be used together with a connected pump.

SpaceControl can be used with a single pump as one stand-alone unit.

SpaceControl also can be used together with SpaceStation as a central user interface for all pumps.

SpaceControl does not have an integrated power source, it receives the power via the pump also if it is used with SpaceStation.

SpaceControl adapts itself to the data of the connected pump.

The „brain“ is located in the pumps.

Page 5: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 5

SpaceControl with SpaceStation

SpaceControl with SpaceStation

SpaceControl with Perfusor Space

SpaceControl with Perfusor Space

SpaceControl with Infusomat Space

SpaceControl with Infusomat Space

SpaceControl - Variants of Applications

Page 6: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 6

SpaceControl – Safety Features

Colored user surface with clearly structured menus for a safe operation

The Main MenuThe Main Menu

Page 7: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 7

SpaceControl – Safety Features

Comfortable and safe data input via barcode reader

Pre-set medications for a safe input of drug-related parameters.

The barcoded drug parameters can be identical with the parameters in the drug library.

Barcode- and druglist editor as a common software tool.

The barcode data include all drug parameters as well as patient ID and colored-related drug illuminations.

Page 8: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 8

SpaceControl – Safety Features

Safe central data input per pump

Selection of the pump directly at the pump assures that the right data will be transmitted to the right pump

1

2

Choose your pump to be modified

A log-in key at the pump adapts the required pump to SpaceControl.

Then set parameters at SpaceControl

No mix up of pumps

Page 9: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 9

SpaceControl – Therapy Diversity

Therapy Profiles: Standard Mode (continuous

infusion, also at Pump available)

Ramping/Tapering Profile Step- /Circadian Profile PCA OTCI

Piggy Back (also at Infusomat available)

After the Profiles have been programmed the pumps continue the infusion also without SpaceControl.

More therapy flexibility to Perfusor- and Infusomat Space with SpaceControl.

Profiles in red only programmable with SpaceControl.

Page 10: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 10

Ramping-/Tapering

Slide increasing and decreasing of the Infusion rate, mainly used for Total Parenteral Nutrition.

SpaceControl – Therapy Diversity

Page 11: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 11

Setting chronobiological profiles For oncological drugs The profile can be repeated with a choosed amount of cycles

Time

Ra

te

One Loop

Step time

Step 1

Step 2

Step 3

Step 4

Step 5

Step 6

Loop time

Step 6

Loop 1 Loop 2 … Loop n

Time

Ra

te

One Loop

Step time

Step 1

Step 2

Step 3

Step 4

Step 5

Step 6

Loop time

Step 6

Loop 1 Loop 2 … Loop n

Step-/Circadian Profile

SpaceControl – Therapy Diversity

Page 12: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 12

Anesthesia OperationsAnesthesia Operations

PCA & Target Controlled InfusionPCA & Target Controlled Infusion

SpaceControl – Therapy Diversity

Page 13: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 13

Perfusor- And Infusomat Space can be loaded with a PCA profile.

No modification of the pump housing for therapy lock necessary.

A special container compartment for the Infusomat Space offers an outstanding feature for comfortable mobility.

Three Safety levels for parameter adjustments via the service menu available.

Time

Ra

te

Observation interval

Lockout time

Basal rate

Bolus rate

Successful bolus demand

Unsuccessful bolus demand

Initial Bolus

Time

Ra

te

Observation interval

Lockout time

Basal rate

Bolus rate

Successful bolus demand

Unsuccessful bolus demand

Initial Bolus

Patient Controlled Analgesia (PCA)

SpaceControl – Therapy Diversity

Page 14: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 14

Safety

Locking mechanism Perfusor Space

Via a PCA key the syringe holder can be locked to prevent unauthorized remove of the syringe

Container 250 ml for adoption to Infusomat Space

Bag compartment, easily to be pushed underneath

the pump.

Patient Controlled Analgesia (PCA)

SpaceControl – Therapy Diversity

Page 15: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 15

B.Braun SpaceStation with 3 Perfusor Space and B. Braun SpaceControl is a combination of components

of the B.Braun Space System, optimized for

Total Intra Venous Anesthesia.

The application of certain drugs may be performed as OTCI.

Target Controlled Infusion

SpaceControl – Therapy Diversity

Page 16: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 16

Smallest and lightest TIVA workstation Integrated battery pack for a safe and easy transport from

induction room to OR. Easy transport of the TCI pump because OTCI is incorporated in

the pumps Lower costs due to the use of generic Propofol Higher user comfort by

- Touch Screen- Graphical color display of therapy courses

Higher patient safety by- Showing effect site concentrations- Using drug library with predefined rate-limits

Target Controlled Infusion – Features and Benefits

SpaceControl – Therapy Diversity

Page 17: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 17

The Workflow in Anesthesia with B.Braun Space

ICU

Induction Room Operation Theatre Recovery Room

Ward

with PCA button

Page 18: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 18

Features and Benefits

Cost efficiency by using OTCI instead of TCI (LOCK function) Prevention of Propofol overdose (OTCI) Reduced wake-up-times (due to lower levels in OTCI) Reduced recovery times (due to lower levels in OTCI) Better usage due to touch screen Safe operation due to the innovative simple menu structure

Target Controlled Infusion

SpaceControl – Therapy Diversity

Page 19: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 19

Where to sell

Completion of existing balanced anesthesia devices (highest potential)

Promotion of B.Braun SpaceAnesthesia exclusively for TIVA (has the advantage that no gas-scavenging is needed and a normal ventilator can be used)

In hospitals, in ambulatory operation centers, for general practitioners

Page 20: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 20

Features of SpaceControl for Anesthesia Color screen with comprehensive information Touch screen usage Structure

- Basic informantion area on top- Navigation area on the right side- Information and controlling area in the

middle PCA-button SP for Lock-Function Bolus possibility

SpaceControl – Therapy Diversity

Page 21: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 21

The OTCI Screen

Page 22: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 22

SpaceControl – Further Options: Occlusion Pressure

Automatic Pressure limit

Always having the optimal alarm triggering time

Pressure setting in steps Pressure lost alarm For a better identification of disconnected cannulae

Page 23: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 23

SpaceControl – Further Options: Patient Data

The complete data file of the patient at a glance.

Page 24: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 24

SpaceControl – Further Options: Data Lock

Data Lock in 2 levels for a single pump or centrally for all pumps in one bed-side system.

Page 25: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 25

SpaceControl – Further Options: History

Memory of 1000 events in each pump. SpaceControl picks up these pump data and is able to visualize these data

Page 26: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 26

SpaceControl – Further Options: Configuration of the Display

Configuration of the display for individual needs: Run graphic Display (Brightness, contrast Country-specific values for pressure (mmHG, bar etc.), Date, clock adjustments

Page 27: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 27

SpaceControl – Further Options: System Data

This function enables the user to control functions of SpaceCom (see Chapter SpaceCom)

Page 28: Strategic Marketing ICU&OR Systems Nov 13, 2003 Chapter 5.2 - 1 Sales Manual B.Braun Space Chapter 5.2  Overview  Variants in Application  Safety features

Sales Manual B.Braun SpaceStrategic Marketing ICU&OR SystemsNov 13, 2003

Chapter 5.2 - 28

SpaceControl – Further Options: Standby

Standby offers 2 options Standby of the single pump Central Standby of all pumps in the system, e.g. for therapy interruption