STO uPVC VENTED
ADJUSTABLE FOOT TRAY
SCALE 1:5
6mm OVERHANG
RECOMMENDED TO
AVOID VARIANCES IN
FOUNDATION
TIMBER FRAMING
TO NZS 3604
DPC
INTERIOR LINING
225m
m M
IN
.
TO
U
NP
AV
ED
G
RO
UN
D LE
VE
L
50m
m
clad.
150m
m M
IN
.
TO
P
AV
ED
G
L
WALL UNDERLAY
STOTHERM RENDER SYSTEM
CAVITY SPACERS TO SUIT
FIXINGS
AS PER NZS 3604
STOTHERM PANEL
FIXING
6
STO RENDER SYSTEM
ON FOUNDATION
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN - NOT SHOWN
FOR CLARITY
DPM
INSULATION
AS PER NZBC
H1/AS1
100m
m M
IN
.
Sto P
laster
50m
m
Flexyl
STOTHERM 20mm VH
CAVITY BATTENS
STOTHERM PANEL
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
FOUNDATION SLAB-ON-GROUND
ST 200
2017
SCALE 1:5
5mm MIN GAP
STO uPVC VENTED BASE CAP
6mm OVERHANG
RECOMMENDED TO AVOID
VARIANCES IN FOUNDATION
TIMBER FRAMING
TO NZS 3604
DPC
225m
m M
IN
.
TO
U
NP
AV
ED
G
RO
UN
D LE
VE
L
150m
m M
IN
.
TO
P
AV
ED
G
L
WALL UNDERLAY
STOTHERM 20mm VH CAVITY
BATTENS
STOTHERM RENDER SYSTEM
STOTHERM PANEL FIXING
CAVITY SPACERS TO SUIT FIXINGS
AS PER NZS 3604
5
STOTHERM PANEL
STO FLEXYL WATERPROOFING
TO REBATE
INSULATED FOUNDATION WITH
STOTHERM RENDER SYSTEM ON
STOFLEXYL WATERPROOFING
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN - NOT SHOWN
FOR CLARITY
DPM
INSULATION AS
PER NZBC -
Clause H1
100m
m M
IN
.
Sto R
ender
50m
m
Clad.
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
INSULATED SLAB-ON-GROUND
ST 201
2017
SCALE 1:5
TIMBER FRAMING
TO NZS 3604
DPC
STO RENDER SYSTEM
INTERNAL LINING
DPM
AS PER NZS 3604
75mm
rebate
BUILDING UNDERLAY
20mm DRAINED CAVITY
STOTHERM PANEL
STO FLEXYL OR LIQUID DPM ON
REBATE
STO uPVC CONTROL JOINT OR
FINISHING EDGE AT JUNCTION
TO FOUNDATION
WEATHER PROTECTED VENTS
TO ACHIEVE MIN. VENTILATION
OF 1000mm²/LINEAL METER
POSITIONED HARD ON REBATE
10
INSULATION TO EXTERIOR
WALLS
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN - NOT SHOWN
FOR CLARITY
STOTHERM PANEL
FIXING
INSULATION AS
NZBC H1/AS1
100m
m M
IN
.
Sto R
ender
50m
m
flexyl
50m
m
Clad.
100m
m
to paving
STOTHERM RENDER
SYSTEM
STO uPVC END CAP
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
REBATED SLAB-ON-GROUND - RENDERED FINISH
ST 202
2017
SCALE 1:5
50m
m
cladding
150m
m to paving
225m
m unpaved G
L
DPC
GL
WALL UNDERLAY
STOTHERM PANEL
FIXING
STOTHERM PANEL
STO uPVC VENTED
BASE CAP
STOTHERM 20mm VH
CAVITY BATTENS
STOTHERM RENDER
SYSTEM
CAVITY SPACERS TO
SUIT FIXINGS
RIBRAFT POLYSTYRENE POD
INSTALLATION IN ACCORDANCE TO FIRTH
RIBRAFT CONSTRUCTION DETAILS
85
220
CONCRETE SLAB/REINFORCING
AS PER NZS 3604, SPECIFIC
DESIGN OR ENGINEER (SED)
Reinforcing not shown for clarity
300
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
RIBRAFT FLOOR SYSTEM / EDGE DETAIL
ST 203
2017
225m
m unpaved G
L
SCALE 1:5
CONCRETE FOOTING AS
PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN
DPC
NOTE:
SHELL OF BLOCK CAN SUPPORT
BOTTOM PLATE WHEN SLAB IS
TIED TO FOUNDATION
50m
m
cladding
150m
m to paved
GL
INSULATION AS PER
NZBC - Clause H1
DPM
STO uPVC VENTED
BASE CAP
WALL UNDERLAY
STOTHERM 20mm VH
CAVITY BATTENS
STOTHERM RENDER
SYSTEM
STOTHERM PANEL
FIXING
STOTHERM PANEL
CAVITY SPACERS TO
SUIT FIXINGS
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
CONC.BLOCK FOUNDATION EDGE DETAIL
ST 204
2017
SCALE 1:5
CONCRETE FOOTING AS
PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN
DPM REQUIRED ON
FOUNDATION FOR POORLY
DRAINED SITES OTHERWISE
TERMINATE AT BOTTOM
EXTERNAL CORNER OF
FOUNDATION
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN
DPC
NOTE:
INSTALL STOFLEXYL UNDER DPM AT TRANSITION IF REQUIRED FOR POORLY
DRAINED SITES.
STO uPVC VENTED BASE
CAP - 5mm MIN.GAP
WALL UNDERLAY
STOTHERM 20mm VH
CAVITY BATTENS
STOTHERM RENDER
SYSTEM
STOTHERM PANEL
FIXING
STOTHERM PANEL
CAVITY SPACERS TO
SUIT FIXINGS
DPM
INSULATION AS PER
NZBC - Clause H1
STOFLEXYL WATERPROOFING
TO REBATE, CONTINUE TO
50mm PAST STO RENDER
TERMINATION POINT
100m
m
Sto R
ender
50m
m
Flexyl
50m
m
cladding
150m
m
TO
P
AV
ED
G
L
225m
m
TO
U
NP
AV
ED
G
RO
UN
D LE
VE
L
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
EPS BLOCK FOUNDATION DETAIL
ST 205
2017
SCALE 1:5
50m
m
cladding
150m
m to paved
225m
m unpaved G
L
INSULATION AS PER
NZBC - Clause H1
DPM
DPC
10mm INSULATION
IF REQUIRED
GL
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR SPECIFIC
ENGINEER DESIGN (SED)
Varies
refer to N
ZS
3604 or S
ED
WALL UNDERLAY
STOTHERM PANEL FIXING
STOTHERM PANEL
STO uPVC VENTED
BASE CAP
STOTHERM 20mm VH
CAVITY BATTENS
STOTHERM RENDER
SYSTEM
CAVITY SPACERS TO
SUIT FIXINGS
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
SOLID CONC.FOUNDATION EDGE DETAIL
ST 206
2017
SCALE 1:5
TIMBER FRAMING/STUCTURE
TO NZS 3604
DPC
STO uPVC VENTED
ADJUSTABLE FOOT TRAY
SELECTED
FLOORING
50
NOTE:
1. CONTINUOUS PERIMETER FOUNDATION
WALL WITH VENTILATION OPENINGS
2. CLEARANCE BETWEEN CLADDING AND
ADJACENT GROUND - REFER NZS3604
SED - Specific Engineer Design
100mm DRAPE TO DBL SIDED
PERFORATED FOIL INSUL.R = 0.9
- REFER NZBC - Clause H1
as per N
ZS
3604
or S
ED
as per N
ZS
3604
or S
ED
CGL
FGL
as per NZS3604
MA
X.H
EIG
HT
- N
ZS
3604 6.11.2
MIN
.H
EIG
HT
6.11.2
WALL UNDERLAY
STOTHERM 20mm VH CAVITY
BATTENS
STOTHERM RENDER SYSTEM
STOTHERM PANEL
FIXING
STOTHERM PANEL
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
CONC.CONTINOUS PERIMETER FOUND.WALL
ST 207
2017
DPC
WALL UNDERLAY
STOTHERM PANEL FIXING
STOTHERM PANEL
STO uPVC VENTED BASE CAP
20mm DRAINED CAVITY
STOTHERM RENDER
SYSTEM
CAVITY SPACERS TO SUIT
FIXINGS
1. CONCRETE SLAB/REINFORCING AS PER NZS 3604, SPECIFIC DESIGN OR
ENGINEER (SED)
Reinforcing not shown for clarity
2. WHERE INSULATION OS BELOW GROUND, APPLY TWO (2) COATS OF
STOFLEXYL TO MAXRAFT INSULATION BEFORE COMMENCING
3. 150mm MIN. CLEARANCE FROM SLAB LEVEL TO EXTERIOR PAVING,
225mm MIN. CLEARANCE FROM SLAB LEVEL TO UNPAVED GROUND TO
E2/AS1
4. AS REQUIRED, SECURE THE DPM TO THE MAXRAFT EDGE INSULATION
USING AN EIFS FLASHING TAPE 50mm ON MAXRAFT AND 100MM ONTO
UNDERSLAB DPM
SOLID COMPACTION 800mm
MIN.PAST EDGE OF
FOUNDATION
100
100
50
250
50
10
450
STOMULTI SCREED MESHED
BASECOAT FINISHED IN
1.0mm FLOAT or STOLIT K
FINISHING RENDER,
PAINTED IN STOCOLOR
MAXICRYL
SCALE 1:10
DPM REFER NOTE 4
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
MAXRAFT FLOOR SYSTEM / EDGE DETAIL
ST 208
2017
MIN. H1.2 TREATED
FLOOR JOISTS
20
20
50
100mm DRAPE TO
DOUBLE-SIDED PERFORATED
FOIL INSULATION R = 0.9 -
REFER NZBC - Clause H1
2/NAIL LAMINATED FLOOR JOISTS
UNDER LOAD BEARING WALLS
STO uPVC VENTED
ADJUSTABLE FOOT TRAY
WALL UNDERLAY
STOTHERM 20mm VH CAVITY
BATTENS
STOPOREN RENDER SYSTEM
STOTHERM PANEL
FIXING
STOTHERM PANEL
H4 TREATED BASEBOARDS
WITH 20mm CONTINUOUS SUB
FLOOR VENTILATION GAP
BETWEEN
H3.2 TREATED BEARER, H5
TREATED PILE - REFER NZS 3604
FOR TIMBER & PILE SETOUT
STOTHERM PANEL
FIXING
NOTE:
FOR CLEARANCE BETWEEN
CLADDING AND ADJACENT GROUND
- REFER NZS3604
SCALE 1:5
STOTHERM RENDER
SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
TIMBER PILE/SUBFLOOR VENTILATION (Parallel Wall)
ST 209
2017
50
100mm DRAPE TO
DOUBLE-SIDED PERFORATED
FOIL INSULATION R = 0.9 -
REFER NZBC - Clause H1
MIN. H1.2 TREATED
FLOOR JOISTS
TRIMMER JOIST
20
20
H4 TREATED BASEBOARDS
WITH 20mm CONTINUOUS SUB
FLOOR VENTILATION GAP
BETWEEN
SELECTED FLOORING
TIMBER FRAMING
TO NZS 3604
WALL UNDERLAY
STOTHERM 20mm VH CAVITY
BATTENS
STOTHERM RENDER SYSTEM
STOTHERM PANEL
FIXING
STOTHERM PANEL
STO uPVC VENTED
ADJUSTABLE FOOT TRAY
H5 TREATED PILE - REFER
NZS 3604 FOR TIMBER & PILE
SET OUT
SCALE 1:5
STOTHERM PANEL
FIXING
NOTE:
FOR CLEARANCE BETWEEN
CLADDING AND ADJACENT
GROUND - REFER NZS3604
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
TIMBER PILE/SUBFLOOR VENTILATION (Right Angled Wall)
ST 210
2017
SCALE 1:5
OVERHANG TRIMMER JOIST
TO ALLOW CLADDING TO LAP
SUBFLOOR CLADDING
100mm DRAPE TO
DOUBLE-SIDED PERFORATED
FOIL INSULATION R = 0.9 -
REFER NZBC - Clause H1
JACK FRAMING IN AS PER
NZS3604 6.10.2
DPC
WALL UNDERLAY
STOTHERM 20mm VH CAVITY
BATTENS
STOTHERM RENDER SYSTEM
STOTHERM PANEL
STO uPVC VENTED
ADJUSTABLE FOOT TRAY
PROVIDE SHEET BRACING
MATERIAL and VENTILATION AS PER
NZS 3604
STOTHERM PANEL
FIXING
STOTHERM PANEL
FIXING
NOTE:
FOR CLEARANCE BETWEEN
CLADDING AND ADJACENT
GROUND - REFER NZS3604
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
TIMBER SUBFLOOR WITH JACK STUDS
ST 211
2017
SCALE 1:10
STO FLEXYL MESHED WATERPROOFING
FROM 150mm ABOVE GROUND AND
DOWN OVER COMPRESSION BAR
SLAB-ON-GROUND FLOOR & CONC.MASONRY WALLS AS PER NZS
4210/4229/4230 & AND ENGINEERS DRAWINGS
ALLOW ADEQUATE TIME FOR BLOCK TO DRY/STABALISE BEFORE
PLASTERING NORMALLY FROM 4-8 WEEKS IN AVERAGE DRYING
CONDITIONS.
STOARMAT RENDER SYSTEM
TIMBER FRAMING
TO NZS 3604
50m
m
DPC
SELECTED
INTERIOR LINING
CONCRETE FLOOR SLAB,
FOOTING & WALL TO SPECIFIC
DESIGN
SELECTED INTERIOR
RENDER/FINISH
FILTER FABRIC
SLOTTED DRAIN LAID
TO A FALL
WALL UNDERLAY
NOMINAL 20x45mm H3.1 TIMBER
CAVITY BATTENS
STOTHERM PANEL FIXING
STOTHERM PANEL
STOTHERM RENDER SYSTEM
STO uPVC VENTED
ADJUSTABLE FOOT TRAY
NOTE:
FOR CLEARANCE BETWEEN
CLADDING AND ADJACENT
GROUND - REFER NZS3604:2011
TANKING SEALANT
COMPRESSION BAR MECHANICALLY
FIXED TO CONC.BLOCK. TRANSITION
APPROX 100mm BELOW GROUND
GRANDULAR FILL RECOMMENDED
SELECTED BITUMOUS PEEL &
STICK TANKING MEMBRANE WITH
PROTECTION MATERIAL
INSULATE BLOCKWORK IF
NEEDED
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
MASONRY CONC.BLOCK IN-GROUND WALL
ST 212
2017
SCALE 1:2
STOFLEXYL WATERPROOFING TO
CONCRETE REBATE SURFACES AND
RENDER INTO REBATE
STOARMAT RENDER SYSTEM
TIMBER FRAMING
TO NZS 3604
DPC
NOTE:
CUT SLOPE AT 15° OR CUT
REBATE AND PLASTER 15°
SLOPE IN.
WALL UNDERLAY
STOTHERM 20mm VH CAVITY
BATTENS
STOTHERM RENDER SYSTEM
STOTHERM PANEL FIXING
STOTHERM PANEL
STO uPVC VENTED BASE
CAP
50m
m
REINFORCED CONCRETE BLOCK
WALLS IN ACCORDANCE WITH NZS
4230, 4229, 4218 & 4210
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by Registered
Architects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right to
alter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insure
they have and use the current Sto details and specifications on site.
STOTHERM
SYSTEM
STOTHERM INSULATED FACADE SYSTEM
CONCRETE BLOCK INTER-STOREY DRAINED JUNCTION
ST 213