105
STORMWATER MANAGEMENT REPORT CROWN MERCEDES CITY OF DUBLIN, FRANKLIN COUNTY, OHIO Prepared By: ENGINEERS & SURVEYORS 422 BEECHER ROAD GAHANNA, OHIO 43230 Ph: 614‐428‐7750 Fax: 614‐428‐7755 Date: April 8, 2017

STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Embed Size (px)

Citation preview

Page 1: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

STORMWATER  MANAGEMENT REPORT 

CROWN MERCEDES 

 

CITY OF DUBLIN, FRANKLIN COUNTY, OHIO

Prepared By:

ENGINEERS & SURVEYORS 

422 BEECHER ROAD GAHANNA, OHIO 43230 

Ph: 614‐428‐7750 Fax: 614‐428‐7755 

  

Date: April 8, 2017 

    

Page 2: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

City of Dublin  Crown Mercedes  April 8, 2017 

2

 

TABLE OF CONTENTS   

STORMWATER MANAGEMENT REVIEW:  

Site Summary: ............................................................................................................................................... 3 

Design Methodology: .................................................................................................................................... 3 

Pre‐Developed Conditions: ........................................................................................................................... 3 

Post‐Construction Conditions: ...................................................................................................................... 3 

Critical Storm: ............................................................................................................................................... 4 

Allowable Release Rates: .............................................................................................................................. 4 

Stormwater Quantity Control: ...................................................................................................................... 4 

Stormwater Quality Control:......................................................................................................................... 5 

Conclusion: .................................................................................................................................................... 5 

        APPENDICES:  

APPENDIX A:  Tributary Map     APPENDIX B:   Soil Survey     APPENDIX C:   Pre‐Developed HydroCAD Calculations    APPENDIX D:  Post‐Developed HydroCAD Calculations   APPENDIX E:  Water Quality Calculations     

  

       

Page 3: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

City of Dublin  Crown Mercedes  April 8, 2017 

3

SiteSummary:The Crown Mercedes project is located on the north side of Perimeter Loop Road in the City of Dublin, Franklin  County, Ohio.  The  project  site  is  surrounded  by  existing  Private  road Mercedes Drive  to  the north, Commercial property to the east, and Perimeter Loop Road to the south and west. The total site is approximately 5.85 acres and consists of an existing auto dealership. The project consists of building additions and necessary site support work.        

DesignMethodology:Stormwater  management  calculations  within  this  report  follow  the  guidance  of  the  City  of  Dublin, Stormwater Management Design Manual (dated June, 2013), for the water quantity and water quality requirements. Hydrology and hydraulics were modeled with  the HydroCAD software suite using TR‐55 methodology and a Type‐II rainfall distribution. Pond routing for the project will be performed using the storage indication method.  Located  in  the  City  of  Dublin,  Stormwater  Management  Design  Manual,  are  the  precipitation frequencies for the 1, 2, 5, 10, 25, 50, and 100 year storm events used to evaluate rainfall and runoff.   

Design Event (yr)  1  2  5  10  25  50  100 

Rainfall Depth (in)  2.20  2.63  3.24  3.74  4.44  5.02  5.63 

Table 1 ‐ Design Storm Rainfall Depths 

Pre‐DevelopedConditions:A review of the Franklin County soil maps show that this site is underlain predominately by Kokomo silty clay‐loam  and  Lewisburg‐Crosby  Complex  with  a  small  fraction  of  Crosby  silt‐loam.  These  soils  are classified within  hydrologic  groups  “D”.  The  existing  site  is  located within  the  South  Fork  Indian  Run Watershed. The onsite runoff is divided into three watersheds, Northwest, North‐Northeast, and South. The site predominately  is  located with the Sub‐basin 1390 with a small portion of each the Northwest and  South watersheds  located  in  Sub‐Basin 1400.  This  report will  only  analyze  the onsite watersheds being impacted by the proposed redevelopment. Pre‐development runoff volume was only calculated to the 1390 – South portion of the site as this is the main controlling factor for site release on the project.  

  Area  CN  Impervious area  1‐yr, 24 hr runoff volume 

Sub‐Basin  (acres)    (acres)  (ac‐ft) 

1390 – North‐Northeast  1.726  94  1.344  0.228 

1390 ‐ South  1.654  92  1.128  0.195 

1400 ‐ South  0.328  87  0.124  0.029 

Table 2 ‐ Pre‐Developed Hydrology Summary 

Post‐ConstructionConditions:The  redevelopment  consists  of  building  additions,  along  with  some  minor  parking  lot  changes.  The proposed building addition located in the North‐Northeast watershed will not  increase the impervious surface and therefor no changes will be required to the existing stormwater management system. This portion of the site will not be further analyzed in this report. The South watershed improvements will increase the impervious surface and therefor increase the runoff. This portion of the site will be further analyzed in this report, below is a summary of the post‐development conditions. This summary includes the portion of the site that is located in Sub‐basin 1400.       

Page 4: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

City of Dublin  Crown Mercedes  April 8, 2017 

4

  Area  CN  Impervious area  1‐yr, 24 hr runoff volume 

Name  (acres)    (acres)  (ac‐ft) 

Disturbed Watershed  1.982  93  1.386  0.248 

Table 3 ‐ Post‐Developed Hydrology Summary 

CriticalStorm:Per the City of Dublin’s, Stormwater Management Design Manual, a critical storm event was computed by evaluating the increase in runoff volume created by the development. Using the scs curve number method, runoff depths from a 2.2 inch rainfall event (1‐yr) were calculated.  

Percent Increase = [(QPost ‐ QPre) / QPre] * 100 [(0.248 – 0.195) / 0.195] * 100 = 27% 

Critical Storm = 5‐yr strom 

AllowableReleaseRates:The allowable release is based on the City of Dublin’s Stormwater Master Plan and the watershed the site is located in. This site in located in the South Fork Indian Run Watershed, Sub‐basin 1390, and Table 4 below summarizes the release rate requirements per Dublin’s Master Stormwater Plan.  

 1  2  5  10  25  50  100 

(cfs/ac)  (cfs/ac) (cfs/ac) (cfs/ac) (cfs/ac) (cfs/ac)  (cfs/ac)

Sub‐Basin 1390  0.9  1.1  1.4  1.7  2.2  2.9  3.6 

Table 4 – Release Rate Requirements 

StormwaterQuantityControl:Control  of  storm  water  runoff  from  the  disturbed  onsite  watershed  will  be  accomplished  within  an underground ADS StormTech system designed to restrict discharges below the allowable peak rates of runoff and provide  the  required water quality  treatment. Table 5 below provides  the site  stormwater runoff summary and Table 6 below provides the storage requirements  for  the underground detention system. Allowable release rates are based on Sub‐basin 1390 area only (release rate x 1.654 acres).   

  1  2  5  10  25  50  100 

Pre‐developed Q (cfs)  3.50  4.43  5.76  6.84  8.35  9.59  10.90 

Post‐developed Q (cfs)  4.40  5.52  7.10  8.39  10.20  11.68  13.23 

Allowable Release (cfs)  1.49  1.49  1.49  2.81  3.64  4.80  5.95 

Actual release (cfs)*  0.94  1.18  1.45  2.27  3.59  3.42  4.26 

Table 5 – Stormwater Runoff Summary *_See Release Rates from the StormTech System nodes in Appendix J 

 

Location Available 

(cf) Required 

(cf) Elevation

 Depth (ft) 

TC Elev.  

Area (sf) 

Control Feature 

Catch Basin #2  1,713  402  917.98  0.31  917.67  402  10.5” Orifice 

Catch basin #4  3,232  2,835  918.51  1.29  917.22  2,877  12” Pipe 

SC‐740 Units  11,764  11,666  916.38  4.18  917.00  5,086  Structure 

Table 6 – 100‐yr Ponding and Storage Summary *Perimeter stone calculated in storage utilizing 40% stone void 

Bottom of perimeter stone = 912.20 ‐ Top of perimeter stone = 916.43 

Page 5: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

City of Dublin  Crown Mercedes  April 8, 2017 

5

StormwaterQualityControl:Per the City of Dublin and the Ohio EPA General Construction Permit, a stormwater best management practice  (BMP)  is  required  to  treat  the  first  flush  runoff  volume produced  by  a ¾”  rainfall  event.  For redevelopment projects  that are a  combination of new development and  redevelopment  that had no post‐construction BMP installed, the Ohio EPA General Construction requires the total WQv that must be  treated  to be,  the new development at 100 percent WQv and  redevelopment at 20 percent WQv. The WQv was calculated using the equation below, the site will use an underground detention system with an Isolator ROW to treat the total WQv requirement. The water quality volume will be detained for a minimum period of 48 hours, releasing less than half of the volume in the first 16 hours. See Appendix E for calculations and drawdown table.   

WQv = (C*P*A/12)  

BMP Tributary Area 

WQv Required

20% Sediment StorageRequired 

Total WQv Required 

WQv Provided 

WQ Elevation

  (acres)  (ft3)  (ft3)  (ft3)  (ft3)  (ft) 

New development  0.122  296  59  355  ‐  ‐ 

Redevelopment  2.032  547  109  656  ‐  ‐ 

Total  2.154  843  168  1,011  1,017  912.70 

Table 7 ‐ Water Quality Volume Summary 

Conclusion:The  Crown  Mercedes  site  provides  surface  and  subsurface  stormwater  conveyances  to  carry  runoff safely  through  the  development  into  the  stormwater management  system.  The  disturbed watershed stormwater management  is controlled by an outlet structure within the StormTech Detention System. The  proposed  system provides  peak  flow  rate  control  and  extended  drawdown of  captured water  to comply with the City of Dublin’s peak control requirements and Ohio EPA’s water quality regulations.  

Page 6: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

APPENDIX A

TRIBUTARY MAP

Page 7: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Perimeter Loop Road (60' R/W)

P

e

r

i

m

e

t

e

r

L

o

o

p

R

o

a

d

(

6

0

'

R

/

W

)

Merc

ed

es D

rive (

Pri

vate

)

D

D

D

Inis

hm

ore

Lan

e

(Public)

(

P

u

b

l

i

c

)

Drawing Number:

Project Number:

AD

VA

NC

EDC

IV

IL

DE

SI

GN

EN

GI

NE

ER

SS

UR

VY

EO

RS

Drawn By:

Date:

Scale:

Checked By:

SIT

E P

LA

N

CR

OW

N M

ER

CE

DE

S B

EN

Z

SE

RV

IC

E A

DD

IT

IO

N

CR

OW

N M

ER

CE

DE

S B

EN

Z

1 / 1

VICINITY MAP

GRAPHIC SCALE0

1 inch = 40 feet

8020 40

ADVANCED CIVIL DESIGN, INC.

ENGINEER

ARCHITECTURAL ALLIANCE

ARCHITECT

LEGEND

PARKING CALCULATIONS

OPEN SPACE CALCULATIONS

SITE ZONING INFORMATION

AutoCAD SHX Text
EX.R/W
AutoCAD SHX Text
EX.R/W
AutoCAD SHX Text
EX.P/L
AutoCAD SHX Text
EX.P/L
AutoCAD SHX Text
EX.P/L
AutoCAD SHX Text
EX.R/W
AutoCAD SHX Text
EX.R/W
AutoCAD SHX Text
EX.P/L
AutoCAD SHX Text
EX.P/L
AutoCAD SHX Text
EX.P/L
AutoCAD SHX Text
EX.30"ST
AutoCAD SHX Text
EX.27"ST
AutoCAD SHX Text
EX.21"ST
AutoCAD SHX Text
EX.12"ST
AutoCAD SHX Text
EX.15"ST
AutoCAD SHX Text
EX.18"ST
AutoCAD SHX Text
EX.18"ST
AutoCAD SHX Text
EX.12"ST
AutoCAD SHX Text
EX.8"W.M.
AutoCAD SHX Text
EX.8"W.M.
AutoCAD SHX Text
EX.8"W.M.
AutoCAD SHX Text
EX.8"W.M.
AutoCAD SHX Text
EX.36"ST
AutoCAD SHX Text
EX.42"ST
AutoCAD SHX Text
EX.18"ST
AutoCAD SHX Text
EX.10"ST
AutoCAD SHX Text
EX.18"ST
AutoCAD SHX Text
EX.18"ST
AutoCAD SHX Text
EX.15"ST
AutoCAD SHX Text
EX.12"ST
AutoCAD SHX Text
EX.8"ST
AutoCAD SHX Text
EX.8"ST
AutoCAD SHX Text
EX.8"ST
AutoCAD SHX Text
EX.8"SA
AutoCAD SHX Text
EX.8"SA
AutoCAD SHX Text
EX.8"SA
AutoCAD SHX Text
EX.10"SA
AutoCAD SHX Text
EX.8"SA
AutoCAD SHX Text
EX.12"SA
AutoCAD SHX Text
Hawkins Family Partnership, Ltd. I.N. 199911050279206 2.960 Ac. APN: 273-007004 ZONING: GENERAL COMMERCIAL PLANNED UNIT DEVELOPMENT DISTRICT (PCD)
AutoCAD SHX Text
P.B. 72, Pg. 47
AutoCAD SHX Text
DDR Continental LP. APN: 273-007383
AutoCAD SHX Text
The Manor at Craughwell Village Condominium APN: (Multiple) ZONING:GENERAL COMMERCIAL GENERAL COMMERCIAL PLANNED LOW DENSITY RESIDENTIAL DISTRICT (PLR)
AutoCAD SHX Text
Hawkins Family Partnership, Ltd. APN: 273-005359 OPEN SPACE
AutoCAD SHX Text
S4°13'22"E 345.29'
AutoCAD SHX Text
EX.CURB (TR) (TYP.).
AutoCAD SHX Text
EX.CONC.DRIVE (TR)
AutoCAD SHX Text
EX.CONC. DISPLAY AREA (TR)
AutoCAD SHX Text
EX.STAIRS (TR)
AutoCAD SHX Text
EX.LANDSCAPE (TR)
AutoCAD SHX Text
EX.ASPHALT
AutoCAD SHX Text
PROP.BLDG
AutoCAD SHX Text
EX.BLDG.
AutoCAD SHX Text
PROP.BLDG
AutoCAD SHX Text
PROP.BLDG
AutoCAD SHX Text
PROP.CURB
AutoCAD SHX Text
EX.PARKING (TBR)
AutoCAD SHX Text
EX.ASPHALT
AutoCAD SHX Text
EX.ASPHALT
AutoCAD SHX Text
EX.ASPHALT
AutoCAD SHX Text
EX.ASPHALT
AutoCAD SHX Text
EX.SIDEWALK (TR)
AutoCAD SHX Text
EX.LANDSCAPE (TR)
AutoCAD SHX Text
EX.WALL (TR)
AutoCAD SHX Text
EX.PATIO (TR)
AutoCAD SHX Text
EX.ASPHALT
AutoCAD SHX Text
EX.ASPHALT
AutoCAD SHX Text
EX.CONCRETE
AutoCAD SHX Text
EX.SIDEWALK (TR)
AutoCAD SHX Text
TIRELESS LP APN: 273-008182 ZONING:GENERAL COMMERCIAL GENERAL COMMERCIAL PLANNED UNIT DEVELOPMENT DISTRICT (PCD)
AutoCAD SHX Text
MONROE MUFFLER BRAKE INC. APN: 273-007475 ZONING:GENERAL COMMERCIAL GENERAL COMMERCIAL PLANNED UNIT DEVELOPMENT DISTRICT (PCD)
AutoCAD SHX Text
EX.DISPLAY AREA
AutoCAD SHX Text
EX.DISPLAY AREA
AutoCAD SHX Text
EX.BLDG. CROWN KIA
AutoCAD SHX Text
EX.BLDG.
AutoCAD SHX Text
EX.BLDG.
AutoCAD SHX Text
EX.BLDG.
AutoCAD SHX Text
EX.BLDG.
AutoCAD SHX Text
P/L
AutoCAD SHX Text
EX.TREE LINE
AutoCAD SHX Text
EX.R/W
AutoCAD SHX Text
EX.LA.R/W
AutoCAD SHX Text
EX.LA.R/W
AutoCAD SHX Text
DDR Continental LP. APN:273-007383 273-007383 ZONING: GENERAL COMMERCIAL PLANNED UNIT DEVELOPMENT DISTRICT (PCD)
AutoCAD SHX Text
1390 - NORTH-NORTHEAST TRIB AREA = 1.726 AC. IMPERVIOUS PRE = 1.344 AC. IMPERVIOUS POST = 1.344 AC.
AutoCAD SHX Text
1390 - SOUTH TRIB AREA = 1.982 AC. IMPERVIOUS PRE = 1.128 AC. IMPERVIOUS POST = 1.386 AC.
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
EX.EQUIPMENT SCREENING
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
STRUCTURE #4 AREA = 0.96 AC. CN = 92 TC = 10 MIN.
AutoCAD SHX Text
STRUCTURE #2 AREA = 0.393 AC. CN = 91 TC = 10 MIN.
AutoCAD SHX Text
STORMTECH AREA = 0.323 AC. CN = 91 TC = 10 MIN.
AutoCAD SHX Text
ROOF TOP AREA = 0.306 AC. CN = 98 TC = 5 MIN.
AutoCAD SHX Text
CITY OF DUBLIN SUB-BASIN DIVIDE
AutoCAD SHX Text
17-0001-837
AutoCAD SHX Text
PLAN PREPARED BY:
AutoCAD SHX Text
422 Beecher Road
AutoCAD SHX Text
43230
AutoCAD SHX Text
Gahanna, Ohio
AutoCAD SHX Text
ph 614.428.7750
AutoCAD SHX Text
fax 614.428.7755
AutoCAD SHX Text
CLE
AutoCAD SHX Text
Issue Dates:
AutoCAD SHX Text
PLAN PREPARED FOR:
AutoCAD SHX Text
TMW
AutoCAD SHX Text
FOR
AutoCAD SHX Text
CITY OF DUBLIN, FRANKLIN COUNTY, OHIO
AutoCAD SHX Text
04/06/2017
AutoCAD SHX Text
1" = 40'
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
33
AutoCAD SHX Text
ADVANCED
AutoCAD SHX Text
422 BEECHER ROAD GAHANNA, OH 43230 PHONE (614) 428-7750 FAX (614) 428-7755
AutoCAD SHX Text
150 EAST BROAD STREET 8TH FLOOR COLUMBUS, OH 43215 PHONE (614) 469-7500
AutoCAD SHX Text
Utility Pole
AutoCAD SHX Text
Overhead Electric
AutoCAD SHX Text
Manhole
AutoCAD SHX Text
Catch Basin
AutoCAD SHX Text
Hydrant
AutoCAD SHX Text
Manhole
AutoCAD SHX Text
Service
AutoCAD SHX Text
EXISTING ELECTRIC
AutoCAD SHX Text
Underground Electric
AutoCAD SHX Text
EXISTING SANITARY SEWER
AutoCAD SHX Text
EXISTING WATER
AutoCAD SHX Text
Curb & Gutter Inlet/Manhole
AutoCAD SHX Text
EXISTING STORM SEWER
AutoCAD SHX Text
EXISTING GAS
AutoCAD SHX Text
EXISTING FIBER OPTIC
AutoCAD SHX Text
EXISTING FENCE
AutoCAD SHX Text
EXISTING R/W / P/L
AutoCAD SHX Text
GV
AutoCAD SHX Text
Valve
AutoCAD SHX Text
(TR) = TO REMAIN
AutoCAD SHX Text
(TBR) = TO BE REMOVED
AutoCAD SHX Text
(DND) = DO NOT DISTURB
AutoCAD SHX Text
(TBA) = TO BE ABANDONED
AutoCAD SHX Text
ADVANCED
AutoCAD SHX Text
EXISTING BUILDING:31,261 SQ. FT. 31,261 SQ. FT. BUILDING ADDITION:876 SQ. FT. SHOWROOM ADDITION 876 SQ. FT. SHOWROOM ADDITION 1,204 SQ. FT. RECEPTION ADDITION 6,210 SQ. FT. SERVICE ADDITION TOTAL BUILDING:29,668 SQ. FT. SALES 29,668 SQ. FT. SALES 22,305 SQ. FT. SERVICE 7,621 OUTDOOR DISPLAY PARKING REQUIRED:1 SPACE PER 300 SQ. FT. SALES AREA = 99 1 SPACE PER 300 SQ. FT. SALES AREA = 99 1 SPACE PER 2,000 SQ. FT. OUTDOOR DISPLAY AREA = 4 1 SPACE PER 100 SQ. FT. SERVICE AREA OR 1 SPACE PER SERVICE BAY (WHICHEVER IS GREATER) = 223 TOTAL REQUIRED:326 SPACES 326 SPACES PARKING PROVIDED:110 INVENTORY SPACES 110 INVENTORY SPACES 14 CUSTOMER SPACES 41 SERVICE SPACES 13 SERVICE LOAN SPACES 33 EMPLOYEE SPACES 20 DISPLAY SPACES 48 FLEX SPACES TOTAL PROVIDED:279 SPACES279 SPACES
AutoCAD SHX Text
EXISTING OPEN SPACE: = 1.495 ACRES= 1.495 ACRES
AutoCAD SHX Text
ZONING DISTRICT:GENERAL COMMERCIAL - GENERAL COMMERCIAL - PLANNED UNIT DEVELOPMENT (PUD) PROPOSED USE:AUTO SALES & SERVICES AUTO SALES & SERVICES OWNER:HAWKINS FAMILY PARTNERSHIP, LTD. HAWKINS FAMILY PARTNERSHIP, LTD. TAX DISTRICT:CITY OF DUBLIN-WASH TWP CITY OF DUBLIN-WASH TWP PARCEL NUMBER:273-005562 273-005562 SETBACK REQUIREMENTS: : PERIMETER LOOP DRIVE:50' BUILDING 50' BUILDING 25' PAVEMENT MINIMUM SIDE YARD SETBACK:25' PAVEMENT AND BUILDING 25' PAVEMENT AND BUILDING MINIMUM REAR YARD SETBACK:25' PAVEMENT AND BUILDING 25' PAVEMENT AND BUILDING TOTAL BUILDING COVERAGE:25% OF TOTAL LOT AREA 25% OF TOTAL LOT AREA EXISTING12.3% 12.3% PROPOSED15.5% 15.5% MAXIMUM LOT COVERAGE:70% 70% EXISTING63% (3.674 AC. IMPERVIOUS AREA) 63% (3.674 AC. IMPERVIOUS AREA) PROPOSED65% (3.797 AC. IMPERVIOUS AREA)65% (3.797 AC. IMPERVIOUS AREA)
Page 8: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

APPENDIX B

SOIL SURVEY

Page 9: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Soil Map—Franklin County, Ohio(Crown Mercedes Site)

Natural ResourcesConservation Service

Web Soil SurveyNational Cooperative Soil Survey

5/9/2017Page 1 of 3

4441

050

4441

080

4441

110

4441

140

4441

170

4441

200

4441

230

4441

050

4441

080

4441

110

4441

140

4441

170

4441

200

4441

230

316130 316160 316190 316220 316250 316280 316310 316340 316370 316400 316430

316130 316160 316190 316220 316250 316280 316310 316340 316370 316400 316430

40° 6' 5'' N83

° 9

' 25'

' W40° 6' 5'' N

83° 9

' 12'

' W

40° 5' 58'' N

83° 9

' 25'

' W

40° 5' 58'' N

83° 9

' 12'

' W

N

Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 17N WGS840 50 100 200 300

Feet0 20 40 80 120

MetersMap Scale: 1:1,440 if printed on A landscape (11" x 8.5") sheet.

Soil Map may not be valid at this scale.

Page 10: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

MAP LEGEND MAP INFORMATION

Area of Interest (AOI)Area of Interest (AOI)

SoilsSoil Map Unit Polygons

Soil Map Unit Lines

Soil Map Unit Points

Special Point FeaturesBlowout

Borrow Pit

Clay Spot

Closed Depression

Gravel Pit

Gravelly Spot

Landfill

Lava Flow

Marsh or swamp

Mine or Quarry

Miscellaneous Water

Perennial Water

Rock Outcrop

Saline Spot

Sandy Spot

Severely Eroded Spot

Sinkhole

Slide or Slip

Sodic Spot

Spoil Area

Stony Spot

Very Stony Spot

Wet Spot

Other

Special Line Features

Water FeaturesStreams and Canals

TransportationRails

Interstate Highways

US Routes

Major Roads

Local Roads

BackgroundAerial Photography

The soil surveys that comprise your AOI were mapped at1:15,800.

Warning: Soil Map may not be valid at this scale.

Enlargement of maps beyond the scale of mapping can causemisunderstanding of the detail of mapping and accuracy of soilline placement. The maps do not show the small areas ofcontrasting soils that could have been shown at a more detailedscale.

Please rely on the bar scale on each map sheet for mapmeasurements.

Source of Map: Natural Resources Conservation ServiceWeb Soil Survey URL:Coordinate System: Web Mercator (EPSG:3857)

Maps from the Web Soil Survey are based on the Web Mercatorprojection, which preserves direction and shape but distortsdistance and area. A projection that preserves area, such as theAlbers equal-area conic projection, should be used if moreaccurate calculations of distance or area are required.

This product is generated from the USDA-NRCS certified data asof the version date(s) listed below.

Soil Survey Area: Franklin County, OhioSurvey Area Data: Version 14, Sep 22, 2016

Soil map units are labeled (as space allows) for map scales1:50,000 or larger.

Date(s) aerial images were photographed: Aug 4, 2014—Aug27, 2014

The orthophoto or other base map on which the soil lines werecompiled and digitized probably differs from the backgroundimagery displayed on these maps. As a result, some minorshifting of map unit boundaries may be evident.

Soil Map—Franklin County, Ohio(Crown Mercedes Site)

Natural ResourcesConservation Service

Web Soil SurveyNational Cooperative Soil Survey

5/9/2017Page 2 of 3

Page 11: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Map Unit Legend

Franklin County, Ohio (OH049)

Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI

CrA Crosby silt loam, SouthernOhio Till Plain, 0 to 2 percentslopes

0.2 3.8%

Ko Kokomo silty clay loam, 0 to 2percent slopes

1.9 30.1%

LeB Lewisburg-Crosby complex, 2to 6 percent slopes

4.1 66.1%

Totals for Area of Interest 6.2 100.0%

Soil Map—Franklin County, Ohio Crown Mercedes Site

Natural ResourcesConservation Service

Web Soil SurveyNational Cooperative Soil Survey

5/9/2017Page 3 of 3

Page 12: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

APPENDIX C

PRE-DEVELOPMENT HYDROCAD CALCULATIONS

Page 13: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 5/31/2017Prepared by Advanced Civil Design

Page 1HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 1S: Pre-Dev (North-Northeast)

Runoff = 4.00 cfs @ 12.01 hrs, Volume= 0.228 af, Depth= 1.58"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 001 Rainfall=2.20"

Area (ac) CN Description* 1.344 98* 0.382 80

1.726 94 Weighted Average0.382 22.13% Pervious Area1.344 77.87% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimu m

Summary for Subcatchment 2S: Pre-Dev (1390-South)

Runoff = 3.50 cfs @ 12.01 hrs, Volume= 0.195 af, Depth= 1.42"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 001 Rainfall=2.20"

Area (ac) CN Description* 0.526 80 Grass* 1.128 98 Pavement

1.654 92 Weighted Average0.526 31.80% Pervious Area1.128 68.20% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Summary for Subcatchment 3S: Pre-Dev (1400-South)

Runoff = 0.53 cfs @ 12.02 hrs, Volume= 0.029 af, Depth= 1.06"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 001 Rainfall=2.20"

Area (ac) CN Description* 0.124 98 Pavement* 0.204 80 Grass

0.328 87 Weighted Average0.204 62.20% Pervious Area0.124 37.80% Impervious Area

Page 14: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 5/31/2017Prepared by Advanced Civil Design

Page 2HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Page 15: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 5/31/2017Prepared by Advanced Civil Design

Page 1HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 2S: Pre-Dev (1390-South)

Runoff = 3.50 cfs @ 12.01 hrs, Volume= 0.195 af, Depth= 1.42"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 001 Rainfall=2.20"

Area (ac) CN Description* 0.526 80 Grass* 1.128 98 Pavement

1.654 92 Weighted Average0.526 31.80% Pervious Area1.128 68.20% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 2S: Pre-Dev (1390-South)

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

3

2

1

0

Type II 24-hrDublin 001 Rainfall=2.20"

Runoff Area=1.654 acRunoff Volume=0.195 af

Runoff Depth=1.42"Tc=10.0 min

CN=92

3.50 cfs

Page 16: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 002 Rainfall=2.63"17-0001-837 Crown Mercedes Printed 5/31/2017Prepared by Advanced Civil Design

Page 2HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 2S: Pre-Dev (1390-South)

Runoff = 4.43 cfs @ 12.01 hrs, Volume= 0.250 af, Depth= 1.81"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 002 Rainfall=2.63"

Area (ac) CN Description* 0.526 80 Grass* 1.128 98 Pavement

1.654 92 Weighted Average0.526 31.80% Pervious Area1.128 68.20% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 2S: Pre-Dev (1390-South)

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

4

3

2

1

0

Type II 24-hrDublin 002 Rainfall=2.63"

Runoff Area=1.654 acRunoff Volume=0.250 af

Runoff Depth=1.81"Tc=10.0 min

CN=92

4.43 cfs

Page 17: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 005 Rainfall=3.24"17-0001-837 Crown Mercedes Printed 5/31/2017Prepared by Advanced Civil Design

Page 3HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 2S: Pre-Dev (1390-South)

Runoff = 5.76 cfs @ 12.01 hrs, Volume= 0.329 af, Depth= 2.39"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 005 Rainfall=3.24"

Area (ac) CN Description* 0.526 80 Grass* 1.128 98 Pavement

1.654 92 Weighted Average0.526 31.80% Pervious Area1.128 68.20% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 2S: Pre-Dev (1390-South)

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

6

5

4

3

2

1

0

Type II 24-hrDublin 005 Rainfall=3.24"

Runoff Area=1.654 acRunoff Volume=0.329 af

Runoff Depth=2.39"Tc=10.0 min

CN=92

5.76 cfs

Page 18: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 010 Rainfall=3.74"17-0001-837 Crown Mercedes Printed 5/31/2017Prepared by Advanced Civil Design

Page 4HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 2S: Pre-Dev (1390-South)

Runoff = 6.84 cfs @ 12.01 hrs, Volume= 0.395 af, Depth= 2.87"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 010 Rainfall=3.74"

Area (ac) CN Description* 0.526 80 Grass* 1.128 98 Pavement

1.654 92 Weighted Average0.526 31.80% Pervious Area1.128 68.20% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 2S: Pre-Dev (1390-South)

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

7

6

5

4

3

2

1

0

Type II 24-hrDublin 010 Rainfall=3.74"

Runoff Area=1.654 acRunoff Volume=0.395 af

Runoff Depth=2.87"Tc=10.0 min

CN=92

6.84 cfs

Page 19: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 025 Rainfall=4.44"17-0001-837 Crown Mercedes Printed 5/31/2017Prepared by Advanced Civil Design

Page 5HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 2S: Pre-Dev (1390-South)

Runoff = 8.35 cfs @ 12.01 hrs, Volume= 0.488 af, Depth= 3.54"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 025 Rainfall=4.44"

Area (ac) CN Description* 0.526 80 Grass* 1.128 98 Pavement

1.654 92 Weighted Average0.526 31.80% Pervious Area1.128 68.20% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 2S: Pre-Dev (1390-South)

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

9

8

7

6

5

4

3

2

1

0

Type II 24-hrDublin 025 Rainfall=4.44"

Runoff Area=1.654 acRunoff Volume=0.488 af

Runoff Depth=3.54"Tc=10.0 min

CN=92

8.35 cfs

Page 20: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 050 Rainfall=5.02"17-0001-837 Crown Mercedes Printed 5/31/2017Prepared by Advanced Civil Design

Page 6HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 2S: Pre-Dev (1390-South)

Runoff = 9.59 cfs @ 12.01 hrs, Volume= 0.566 af, Depth= 4.11"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 050 Rainfall=5.02"

Area (ac) CN Description* 0.526 80 Grass* 1.128 98 Pavement

1.654 92 Weighted Average0.526 31.80% Pervious Area1.128 68.20% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 2S: Pre-Dev (1390-South)

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

10

9

8

7

6

5

4

3

2

1

0

Type II 24-hrDublin 050 Rainfall=5.02"

Runoff Area=1.654 acRunoff Volume=0.566 af

Runoff Depth=4.11"Tc=10.0 min

CN=92

9.59 cfs

Page 21: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 5/31/2017Prepared by Advanced Civil Design

Page 7HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 2S: Pre-Dev (1390-South)

Runoff = 10.90 cfs @ 12.01 hrs, Volume= 0.649 af, Depth= 4.71"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 100 Rainfall=5.63"

Area (ac) CN Description* 0.526 80 Grass* 1.128 98 Pavement

1.654 92 Weighted Average0.526 31.80% Pervious Area1.128 68.20% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 2S: Pre-Dev (1390-South)

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

12

11

10

9

8

7

6

5

4

3

2

1

0

Type II 24-hrDublin 100 Rainfall=5.63"

Runoff Area=1.654 acRunoff Volume=0.649 af

Runoff Depth=4.71"Tc=10.0 min

CN=92

10.90 cfs

Page 22: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

APPENDIX D

POST-DEVELOPED HYDROCAD CALCULATIONS

Page 23: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 5/31/2017Prepared by Advanced Civil Design

Page 1HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 4S: Post-Construction Area

Runoff = 4.40 cfs @ 12.01 hrs, Volume= 0.248 af, Depth= 1.50"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 001 Rainfall=2.20"

Area (ac) CN Description* 0.118 80 Str #3 Trib Area - Grass* 0.205 98 Str #3 Trib Area - Pavement* 0.329 80 Str #5 Trib Area - Grass* 0.631 98 Str #5 Trib Area - Pavement* 0.149 80 Str #7 Trib Area - Grass* 0.244 98 Str #7 Trib Area - Pavement* 0.306 98 Roof Top Area

1.982 93 Weighted Average0.596 30.07% Pervious Area1.386 69.93% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Page 24: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

1

Str #4 Trib Area 2

Surface Ponding @ Str #4

3

Str #2 Trib Area

4

Surface Ponding & Pipe Storage 2 @ Str #2

5

Roof Top Trib Area

6

Storm Tech Trib Area7

Underground StormTech System

Routing Diagram for 17-0001-837 Crown MercedesPrepared by Advanced Civil Design, Printed 6/8/2017

HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Subcat Reach Pond Link

Page 25: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 2HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 1: Str #4 Trib Area

Runoff = 2.03 cfs @ 12.01 hrs, Volume= 0.113 af, Depth= 1.42"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 001 Rainfall=2.20"

Area (ac) CN Description* 0.631 98 Pavement* 0.329 80 Grass

0.960 92 Weighted Average0.329 34.27% Pervious Area0.631 65.73% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 1: Str #4 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

2

1

0

Type II 24-hrDublin 001 Rainfall=2.20"

Runoff Area=0.960 acRunoff Volume=0.113 af

Runoff Depth=1.42"Tc=10.0 min

CN=92

2.03 cfs

Page 26: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 3HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 2: Surface Ponding @ Str #4

Inflow Area = 0.960 ac, 65.73% Impervious, Inflow Depth = 1.42" for Dublin 001 eventInflow = 2.03 cfs @ 12.01 hrs, Volume= 0.113 afOutflow = 2.02 cfs @ 12.01 hrs, Volume= 0.113 af, Atten= 0%, Lag= 0.1 minPrimary = 2.02 cfs @ 12.01 hrs, Volume= 0.113 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 914.68' @ 12.04 hrs Surf.Area= 7 sf Storage= 8 cf

Plug-Flow detention time= 0.2 min calculated for 0.113 af (100% of inflow)Center-of-Mass det. time= 0.2 min ( 812.8 - 812.6 )

Volume Invert Avail.Storage Storage Description#1 917.20' 3,206 cf Surface Ponding (Prismatic) Listed below (Recalc)#2 913.52' 26 cf 3.00'D x 3.70'H Str #5

3,232 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.20 4 0 0918.60 4,576 3,206 3,206

Device Routing Invert Outlet Devices#1 Primary 913.52' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 913.52' / 913.28' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=1.99 cfs @ 12.01 hrs HW=914.62' TW=914.26' (Dynamic Tailwater)1=Culvert (Outlet Controls 1.99 cfs @ 2.87 fps)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=913.52' TW=912.94' (Dynamic Tailwater)2=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 27: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 4HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 2: Surface Ponding @ Str #4

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

2

1

0

Inflow Area=0.960 acPeak Elev=914.68'

Storage=8 cf

2.03 cfs2.02 cfs

2.02 cfs

0.00 cfs

Page 28: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 5HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 3: Str #2 Trib Area

Runoff = 0.79 cfs @ 12.01 hrs, Volume= 0.044 af, Depth= 1.34"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 001 Rainfall=2.20"

Area (ac) CN Description* 0.149 80 Grass* 0.244 98 Pavement

0.393 91 Weighted Average0.149 37.91% Pervious Area0.244 62.09% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 3: Str #2 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

0.85

0.8

0.75

0.7

0.65

0.6

0.55

0.5

0.45

0.4

0.35

0.3

0.25

0.2

0.15

0.1

0.05

0

Type II 24-hrDublin 001 Rainfall=2.20"

Runoff Area=0.393 acRunoff Volume=0.044 af

Runoff Depth=1.34"Tc=10.0 min

CN=91

0.79 cfs

Page 29: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 6HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

Inflow Area = 1.353 ac, 64.67% Impervious, Inflow Depth = 1.40" for Dublin 001 eventInflow = 2.81 cfs @ 12.01 hrs, Volume= 0.157 afOutflow = 2.75 cfs @ 12.03 hrs, Volume= 0.157 af, Atten= 2%, Lag= 0.8 minPrimary = 2.75 cfs @ 12.03 hrs, Volume= 0.157 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 914.36' @ 12.04 hrs Surf.Area= 45 sf Storage= 142 cf

Plug-Flow detention time= 1.4 min calculated for 0.157 af (100% of inflow)Center-of-Mass det. time= 1.4 min ( 815.6 - 814.3 )

Volume Invert Avail.Storage Storage Description#1 912.94' 100 cf 3.00'D x 4.73'H Str #2 x 3#2 912.94' 61 cf 12.0" Round Pipe Storage Str #2 - Str #3

L= 77.9' S= 0.0044 '/'#3 913.28' 42 cf 3.00'D x 5.95'H Str #3#4 913.28' 44 cf 12.0" Round Pipe Storage Str #3 - Str #4

L= 55.4' S= 0.0040 '/'#5 917.67' 1,466 cf Str #2 Surface Ponding (Prismatic) Listed below (Recalc)

1,713 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.67 4 0 0918.60 3,148 1,466 1,466

Device Routing Invert Outlet Devices#1 Primary 912.94' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.94' / 912.70' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Device 1 912.94' 10.5" Vert. Orifice Plate C= 0.600 #3 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=2.70 cfs @ 12.03 hrs HW=914.30' TW=913.43' (Dynamic Tailwater)1=Culvert (Passes 2.70 cfs of 2.70 cfs potential flow)

2=Orifice Plate (Orifice Controls 2.70 cfs @ 4.48 fps)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.94' TW=912.20' (Dynamic Tailwater)3=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 30: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 7HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

3

2

1

0

Inflow Area=1.353 acPeak Elev=914.36'

Storage=142 cf

2.81 cfs2.75 cfs

2.75 cfs

0.00 cfs

Page 31: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 8HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 5: Roof Top Trib Area

Runoff = 0.95 cfs @ 11.95 hrs, Volume= 0.050 af, Depth= 1.97"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 001 Rainfall=2.20"

Area (ac) CN Description0.306 98 Roofs, HSG D0.306 100.00% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)

5.0 Direct Entry,

Subcatchment 5: Roof Top Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

1

0

Type II 24-hrDublin 001 Rainfall=2.20"

Runoff Area=0.306 acRunoff Volume=0.050 af

Runoff Depth=1.97"Tc=5.0 min

CN=98

0.95 cfs

Page 32: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 9HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 6: Storm Tech Trib Area

Runoff = 0.65 cfs @ 12.01 hrs, Volume= 0.036 af, Depth= 1.34"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 001 Rainfall=2.20"

Area (ac) CN Description* 0.118 80 Grass* 0.205 98 Pavement

0.323 91 Weighted Average0.118 36.53% Pervious Area0.205 63.47% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 6: Storm Tech Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

0.7

0.65

0.6

0.55

0.5

0.45

0.4

0.35

0.3

0.25

0.2

0.15

0.1

0.05

0

Type II 24-hrDublin 001 Rainfall=2.20"

Runoff Area=0.323 acRunoff Volume=0.036 af

Runoff Depth=1.34"Tc=10.0 min

CN=91

0.65 cfs

Page 33: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 10HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 7: Underground StormTech System

Inflow Area = 1.982 ac, 69.93% Impervious, Inflow Depth = 1.48" for Dublin 001 eventInflow = 4.10 cfs @ 12.00 hrs, Volume= 0.244 afOutflow = 0.97 cfs @ 12.24 hrs, Volume= 0.231 af, Atten= 76%, Lag= 14.2 minPrimary = 0.97 cfs @ 12.24 hrs, Volume= 0.231 afTertiary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 913.71' @ 12.24 hrs Surf.Area= 5,118 sf Storage= 4,817 cf

Plug-Flow detention time= 200.3 min calculated for 0.231 af (95% of inflow)Center-of-Mass det. time= 171.8 min ( 976.3 - 804.6 )

Volume Invert Avail.Storage Storage Description#1 912.20' 2,830 cf Perimeter Stone (Prismatic) Listed below (Recalc)

9,649 cf Overall - 2,573 cf Embedded = 7,076 cf x 40.0% Voids#2 912.70' 2,573 cf ADS_StormTech SC-740 4 Rows of 14 units x 56 Inside #1

Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap4 Rows of 14 Chambers

#3 912.20' 1,628 cf Perimeter Stone (Prismatic) Listed below (Recalc)5,355 cf Overall - 1,286 cf Embedded = 4,069 cf x 40.0% Voids

#4 912.70' 1,286 cf ADS_StormTech SC-740 1 Row of 14 units x 28 Inside #3Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap2 Rows of 14 Chambers

#5 912.20' 1,109 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,507 cf Overall - 735 cf Embedded = 2,772 cf x 40.0% Voids

#6 912.70' 735 cf ADS_StormTech SC-740 - Isolator Row x 16 Inside #5Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#7 912.20' 962 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,003 cf Overall - 597 cf Embedded = 2,406 cf x 40.0% Voids

#8 912.70' 597 cf ADS_StormTech SC-740 - Isolator Row x 13 Inside #7Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#9 912.70' 44 cf 12.0" Round Pipe Storage Storm Tech - Str #2L= 55.4' S= 0.0044 '/'

11,764 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 2,281 0 0916.43 2,281 9,649 9,649

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 1,266 0 0916.43 1,266 5,355 5,355

Page 34: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 11HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 829 0 0916.43 829 3,507 3,507

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 710 0 0916.43 710 3,003 3,003

Device Routing Invert Outlet Devices#1 Primary 912.14' 18.0" Round Culvert

L= 137.9' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.14' / 911.82' S= 0.0023 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 1.77 sf

#2 Device 1 912.20' 0.7" Vert. Underdrain C= 0.600 #3 Device 1 912.70' 6.5" Vert. Orifice C= 0.600 #4 Device 1 915.05' 6.0" W x 7.0" H Vert. Window C= 0.600 #5 Device 1 916.20' 3.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s) #6 Tertiary 916.98' 4.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=0.97 cfs @ 12.24 hrs HW=913.71' (Free Discharge)1=Culvert (Passes 0.97 cfs of 5.43 cfs potential flow)

2=Underdrain (Orifice Controls 0.02 cfs @ 5.86 fps)3=Orifice (Orifice Controls 0.95 cfs @ 4.14 fps)4=Window ( Controls 0.00 cfs)5=Sharp-Crested Rectangular Weir ( Controls 0.00 cfs)

Tertiary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.20' (Free Discharge)6=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 35: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 001 Rainfall=2.20"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 12HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 7: Underground StormTech System

InflowOutflowPrimaryTertiary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

4

3

2

1

0

Inflow Area=1.982 acPeak Elev=913.71'Storage=4,817 cf

4.10 cfs

0.97 cfs0.97 cfs

0.00 cfs

Page 36: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 002 Rainfall=2.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 13HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 1: Str #4 Trib Area

Runoff = 2.57 cfs @ 12.01 hrs, Volume= 0.145 af, Depth= 1.81"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 002 Rainfall=2.63"

Area (ac) CN Description* 0.631 98 Pavement* 0.329 80 Grass

0.960 92 Weighted Average0.329 34.27% Pervious Area0.631 65.73% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 1: Str #4 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

2

1

0

Type II 24-hrDublin 002 Rainfall=2.63"

Runoff Area=0.960 acRunoff Volume=0.145 af

Runoff Depth=1.81"Tc=10.0 min

CN=92

2.57 cfs

Page 37: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 002 Rainfall=2.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 14HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 2: Surface Ponding @ Str #4

Inflow Area = 0.960 ac, 65.73% Impervious, Inflow Depth = 1.81" for Dublin 002 eventInflow = 2.57 cfs @ 12.01 hrs, Volume= 0.145 afOutflow = 2.53 cfs @ 12.02 hrs, Volume= 0.145 af, Atten= 1%, Lag= 0.4 minPrimary = 2.53 cfs @ 12.02 hrs, Volume= 0.145 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 915.71' @ 12.03 hrs Surf.Area= 7 sf Storage= 15 cf

Plug-Flow detention time= 0.2 min calculated for 0.145 af (100% of inflow)Center-of-Mass det. time= 0.2 min ( 805.8 - 805.6 )

Volume Invert Avail.Storage Storage Description#1 917.20' 3,206 cf Surface Ponding (Prismatic) Listed below (Recalc)#2 913.52' 26 cf 3.00'D x 3.70'H Str #5

3,232 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.20 4 0 0918.60 4,576 3,206 3,206

Device Routing Invert Outlet Devices#1 Primary 913.52' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 913.52' / 913.28' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=2.50 cfs @ 12.02 hrs HW=915.60' TW=915.09' (Dynamic Tailwater)1=Culvert (Outlet Controls 2.50 cfs @ 3.19 fps)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=913.52' TW=912.94' (Dynamic Tailwater)2=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 38: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 002 Rainfall=2.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 15HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 2: Surface Ponding @ Str #4

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

2

1

0

Inflow Area=0.960 acPeak Elev=915.71'

Storage=15 cf

2.57 cfs2.53 cfs

2.53 cfs

0.00 cfs

Page 39: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 002 Rainfall=2.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 16HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 3: Str #2 Trib Area

Runoff = 1.01 cfs @ 12.01 hrs, Volume= 0.057 af, Depth= 1.73"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 002 Rainfall=2.63"

Area (ac) CN Description* 0.149 80 Grass* 0.244 98 Pavement

0.393 91 Weighted Average0.149 37.91% Pervious Area0.244 62.09% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 3: Str #2 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

1

0

Type II 24-hrDublin 002 Rainfall=2.63"

Runoff Area=0.393 acRunoff Volume=0.057 af

Runoff Depth=1.73"Tc=10.0 min

CN=91

1.01 cfs

Page 40: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 002 Rainfall=2.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 17HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

Inflow Area = 1.353 ac, 64.67% Impervious, Inflow Depth = 1.79" for Dublin 002 eventInflow = 3.54 cfs @ 12.02 hrs, Volume= 0.202 afOutflow = 3.56 cfs @ 12.02 hrs, Volume= 0.202 af, Atten= 0%, Lag= 0.1 minPrimary = 3.56 cfs @ 12.02 hrs, Volume= 0.202 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 915.18' @ 12.03 hrs Surf.Area= 28 sf Storage= 166 cf

Plug-Flow detention time= 1.6 min calculated for 0.202 af (100% of inflow)Center-of-Mass det. time= 1.6 min ( 808.8 - 807.2 )

Volume Invert Avail.Storage Storage Description#1 912.94' 100 cf 3.00'D x 4.73'H Str #2 x 3#2 912.94' 61 cf 12.0" Round Pipe Storage Str #2 - Str #3

L= 77.9' S= 0.0044 '/'#3 913.28' 42 cf 3.00'D x 5.95'H Str #3#4 913.28' 44 cf 12.0" Round Pipe Storage Str #3 - Str #4

L= 55.4' S= 0.0040 '/'#5 917.67' 1,466 cf Str #2 Surface Ponding (Prismatic) Listed below (Recalc)

1,713 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.67 4 0 0918.60 3,148 1,466 1,466

Device Routing Invert Outlet Devices#1 Primary 912.94' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.94' / 912.70' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Device 1 912.94' 10.5" Vert. Orifice Plate C= 0.600 #3 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=3.45 cfs @ 12.02 hrs HW=915.09' TW=913.67' (Dynamic Tailwater)1=Culvert (Passes 3.45 cfs of 4.13 cfs potential flow)

2=Orifice Plate (Orifice Controls 3.45 cfs @ 5.74 fps)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.94' TW=912.20' (Dynamic Tailwater)3=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 41: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 002 Rainfall=2.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 18HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

3

2

1

0

Inflow Area=1.353 acPeak Elev=915.18'

Storage=166 cf

3.54 cfs3.56 cfs

3.56 cfs

0.00 cfs

Page 42: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 002 Rainfall=2.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 19HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 5: Roof Top Trib Area

Runoff = 1.14 cfs @ 11.95 hrs, Volume= 0.061 af, Depth= 2.40"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 002 Rainfall=2.63"

Area (ac) CN Description0.306 98 Roofs, HSG D0.306 100.00% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)

5.0 Direct Entry,

Subcatchment 5: Roof Top Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

1

0

Type II 24-hrDublin 002 Rainfall=2.63"

Runoff Area=0.306 acRunoff Volume=0.061 af

Runoff Depth=2.40"Tc=5.0 min

CN=98

1.14 cfs

Page 43: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 002 Rainfall=2.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 20HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 6: Storm Tech Trib Area

Runoff = 0.83 cfs @ 12.01 hrs, Volume= 0.047 af, Depth= 1.73"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 002 Rainfall=2.63"

Area (ac) CN Description* 0.118 80 Grass* 0.205 98 Pavement

0.323 91 Weighted Average0.118 36.53% Pervious Area0.205 63.47% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 6: Storm Tech Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

0.9

0.85

0.8

0.75

0.7

0.65

0.6

0.55

0.5

0.45

0.4

0.35

0.3

0.25

0.2

0.15

0.1

0.05

0

Type II 24-hrDublin 002 Rainfall=2.63"

Runoff Area=0.323 acRunoff Volume=0.047 af

Runoff Depth=1.73"Tc=10.0 min

CN=91

0.83 cfs

Page 44: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 002 Rainfall=2.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 21HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 7: Underground StormTech System

Inflow Area = 1.982 ac, 69.93% Impervious, Inflow Depth = 1.87" for Dublin 002 eventInflow = 5.28 cfs @ 12.00 hrs, Volume= 0.309 afOutflow = 1.18 cfs @ 12.24 hrs, Volume= 0.297 af, Atten= 78%, Lag= 14.4 minPrimary = 1.18 cfs @ 12.24 hrs, Volume= 0.297 afTertiary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 914.07' @ 12.24 hrs Surf.Area= 5,086 sf Storage= 6,075 cf

Plug-Flow detention time= 177.2 min calculated for 0.297 af (96% of inflow)Center-of-Mass det. time= 152.5 min ( 951.2 - 798.6 )

Volume Invert Avail.Storage Storage Description#1 912.20' 2,830 cf Perimeter Stone (Prismatic) Listed below (Recalc)

9,649 cf Overall - 2,573 cf Embedded = 7,076 cf x 40.0% Voids#2 912.70' 2,573 cf ADS_StormTech SC-740 4 Rows of 14 units x 56 Inside #1

Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap4 Rows of 14 Chambers

#3 912.20' 1,628 cf Perimeter Stone (Prismatic) Listed below (Recalc)5,355 cf Overall - 1,286 cf Embedded = 4,069 cf x 40.0% Voids

#4 912.70' 1,286 cf ADS_StormTech SC-740 1 Row of 14 units x 28 Inside #3Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap2 Rows of 14 Chambers

#5 912.20' 1,109 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,507 cf Overall - 735 cf Embedded = 2,772 cf x 40.0% Voids

#6 912.70' 735 cf ADS_StormTech SC-740 - Isolator Row x 16 Inside #5Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#7 912.20' 962 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,003 cf Overall - 597 cf Embedded = 2,406 cf x 40.0% Voids

#8 912.70' 597 cf ADS_StormTech SC-740 - Isolator Row x 13 Inside #7Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#9 912.70' 44 cf 12.0" Round Pipe Storage Storm Tech - Str #2L= 55.4' S= 0.0044 '/'

11,764 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 2,281 0 0916.43 2,281 9,649 9,649

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 1,266 0 0916.43 1,266 5,355 5,355

Page 45: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 002 Rainfall=2.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 22HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 829 0 0916.43 829 3,507 3,507

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 710 0 0916.43 710 3,003 3,003

Device Routing Invert Outlet Devices#1 Primary 912.14' 18.0" Round Culvert

L= 137.9' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.14' / 911.82' S= 0.0023 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 1.77 sf

#2 Device 1 912.20' 0.7" Vert. Underdrain C= 0.600 #3 Device 1 912.70' 6.5" Vert. Orifice C= 0.600 #4 Device 1 915.05' 6.0" W x 7.0" H Vert. Window C= 0.600 #5 Device 1 916.20' 3.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s) #6 Tertiary 916.98' 4.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=1.18 cfs @ 12.24 hrs HW=914.07' (Free Discharge)1=Culvert (Passes 1.18 cfs of 6.57 cfs potential flow)

2=Underdrain (Orifice Controls 0.02 cfs @ 6.54 fps)3=Orifice (Orifice Controls 1.16 cfs @ 5.05 fps)4=Window ( Controls 0.00 cfs)5=Sharp-Crested Rectangular Weir ( Controls 0.00 cfs)

Tertiary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.20' (Free Discharge)6=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 46: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 002 Rainfall=2.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 23HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 7: Underground StormTech System

InflowOutflowPrimaryTertiary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

5

4

3

2

1

0

Inflow Area=1.982 acPeak Elev=914.07'Storage=6,075 cf

5.28 cfs

1.18 cfs1.18 cfs

0.00 cfs

Page 47: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 005 Rainfall=3.24"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 24HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 1: Str #4 Trib Area

Runoff = 3.34 cfs @ 12.01 hrs, Volume= 0.191 af, Depth= 2.39"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 005 Rainfall=3.24"

Area (ac) CN Description* 0.631 98 Pavement* 0.329 80 Grass

0.960 92 Weighted Average0.329 34.27% Pervious Area0.631 65.73% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 1: Str #4 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

3

2

1

0

Type II 24-hrDublin 005 Rainfall=3.24"

Runoff Area=0.960 acRunoff Volume=0.191 af

Runoff Depth=2.39"Tc=10.0 min

CN=92

3.34 cfs

Page 48: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 005 Rainfall=3.24"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 25HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 2: Surface Ponding @ Str #4

Inflow Area = 0.960 ac, 65.73% Impervious, Inflow Depth = 2.39" for Dublin 005 eventInflow = 3.34 cfs @ 12.01 hrs, Volume= 0.191 afOutflow = 3.32 cfs @ 12.01 hrs, Volume= 0.191 af, Atten= 1%, Lag= 0.0 minPrimary = 3.32 cfs @ 12.01 hrs, Volume= 0.191 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 917.36' @ 12.03 hrs Surf.Area= 534 sf Storage= 69 cf

Plug-Flow detention time= (not calculated: outflow precedes inflow)Center-of-Mass det. time= 0.2 min ( 798.1 - 797.9 )

Volume Invert Avail.Storage Storage Description#1 917.20' 3,206 cf Surface Ponding (Prismatic) Listed below (Recalc)#2 913.52' 26 cf 3.00'D x 3.70'H Str #5

3,232 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.20 4 0 0918.60 4,576 3,206 3,206

Device Routing Invert Outlet Devices#1 Primary 913.52' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 913.52' / 913.28' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=3.32 cfs @ 12.01 hrs HW=917.20' TW=916.30' (Dynamic Tailwater)1=Culvert (Outlet Controls 3.32 cfs @ 4.22 fps)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=913.52' TW=912.94' (Dynamic Tailwater)2=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 49: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 005 Rainfall=3.24"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 26HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 2: Surface Ponding @ Str #4

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

3

2

1

0

Inflow Area=0.960 acPeak Elev=917.36'

Storage=69 cf

3.34 cfs3.32 cfs

3.32 cfs

0.00 cfs

Page 50: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 005 Rainfall=3.24"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 27HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 3: Str #2 Trib Area

Runoff = 1.33 cfs @ 12.01 hrs, Volume= 0.075 af, Depth= 2.30"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 005 Rainfall=3.24"

Area (ac) CN Description* 0.149 80 Grass* 0.244 98 Pavement

0.393 91 Weighted Average0.149 37.91% Pervious Area0.244 62.09% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 3: Str #2 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

1

0

Type II 24-hrDublin 005 Rainfall=3.24"

Runoff Area=0.393 acRunoff Volume=0.075 af

Runoff Depth=2.30"Tc=10.0 min

CN=91

1.33 cfs

Page 51: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 005 Rainfall=3.24"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 28HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

Inflow Area = 1.353 ac, 64.67% Impervious, Inflow Depth = 2.36" for Dublin 005 eventInflow = 4.64 cfs @ 12.01 hrs, Volume= 0.266 afOutflow = 4.48 cfs @ 12.02 hrs, Volume= 0.266 af, Atten= 3%, Lag= 0.7 minPrimary = 4.48 cfs @ 12.02 hrs, Volume= 0.266 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 916.47' @ 12.04 hrs Surf.Area= 28 sf Storage= 202 cf

Plug-Flow detention time= 1.8 min calculated for 0.266 af (100% of inflow)Center-of-Mass det. time= 1.8 min ( 801.2 - 799.4 )

Volume Invert Avail.Storage Storage Description#1 912.94' 100 cf 3.00'D x 4.73'H Str #2 x 3#2 912.94' 61 cf 12.0" Round Pipe Storage Str #2 - Str #3

L= 77.9' S= 0.0044 '/'#3 913.28' 42 cf 3.00'D x 5.95'H Str #3#4 913.28' 44 cf 12.0" Round Pipe Storage Str #3 - Str #4

L= 55.4' S= 0.0040 '/'#5 917.67' 1,466 cf Str #2 Surface Ponding (Prismatic) Listed below (Recalc)

1,713 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.67 4 0 0918.60 3,148 1,466 1,466

Device Routing Invert Outlet Devices#1 Primary 912.94' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.94' / 912.70' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Device 1 912.94' 10.5" Vert. Orifice Plate C= 0.600 #3 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=4.39 cfs @ 12.02 hrs HW=916.34' TW=914.05' (Dynamic Tailwater)1=Culvert (Passes 4.39 cfs of 5.31 cfs potential flow)

2=Orifice Plate (Orifice Controls 4.39 cfs @ 7.30 fps)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.94' TW=912.20' (Dynamic Tailwater)3=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 52: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 005 Rainfall=3.24"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 29HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

5

4

3

2

1

0

Inflow Area=1.353 acPeak Elev=916.47'

Storage=202 cf

4.64 cfs4.48 cfs

4.48 cfs

0.00 cfs

Page 53: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 005 Rainfall=3.24"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 30HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 5: Roof Top Trib Area

Runoff = 1.42 cfs @ 11.95 hrs, Volume= 0.077 af, Depth= 3.01"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 005 Rainfall=3.24"

Area (ac) CN Description0.306 98 Roofs, HSG D0.306 100.00% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)

5.0 Direct Entry,

Subcatchment 5: Roof Top Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

1

0

Type II 24-hrDublin 005 Rainfall=3.24"

Runoff Area=0.306 acRunoff Volume=0.077 af

Runoff Depth=3.01"Tc=5.0 min

CN=98

1.42 cfs

Page 54: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 005 Rainfall=3.24"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 31HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 6: Storm Tech Trib Area

Runoff = 1.09 cfs @ 12.01 hrs, Volume= 0.062 af, Depth= 2.30"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 005 Rainfall=3.24"

Area (ac) CN Description* 0.118 80 Grass* 0.205 98 Pavement

0.323 91 Weighted Average0.118 36.53% Pervious Area0.205 63.47% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 6: Storm Tech Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

1

0

Type II 24-hrDublin 005 Rainfall=3.24"

Runoff Area=0.323 acRunoff Volume=0.062 af

Runoff Depth=2.30"Tc=10.0 min

CN=91

1.09 cfs

Page 55: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 005 Rainfall=3.24"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 32HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 7: Underground StormTech System

Inflow Area = 1.982 ac, 69.93% Impervious, Inflow Depth = 2.45" for Dublin 005 eventInflow = 6.69 cfs @ 12.00 hrs, Volume= 0.405 afOutflow = 1.45 cfs @ 12.25 hrs, Volume= 0.392 af, Atten= 78%, Lag= 15.1 minPrimary = 1.45 cfs @ 12.25 hrs, Volume= 0.392 afTertiary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 914.63' @ 12.25 hrs Surf.Area= 5,086 sf Storage= 7,854 cf

Plug-Flow detention time= 155.2 min calculated for 0.391 af (97% of inflow)Center-of-Mass det. time= 137.1 min ( 929.0 - 791.9 )

Volume Invert Avail.Storage Storage Description#1 912.20' 2,830 cf Perimeter Stone (Prismatic) Listed below (Recalc)

9,649 cf Overall - 2,573 cf Embedded = 7,076 cf x 40.0% Voids#2 912.70' 2,573 cf ADS_StormTech SC-740 4 Rows of 14 units x 56 Inside #1

Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap4 Rows of 14 Chambers

#3 912.20' 1,628 cf Perimeter Stone (Prismatic) Listed below (Recalc)5,355 cf Overall - 1,286 cf Embedded = 4,069 cf x 40.0% Voids

#4 912.70' 1,286 cf ADS_StormTech SC-740 1 Row of 14 units x 28 Inside #3Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap2 Rows of 14 Chambers

#5 912.20' 1,109 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,507 cf Overall - 735 cf Embedded = 2,772 cf x 40.0% Voids

#6 912.70' 735 cf ADS_StormTech SC-740 - Isolator Row x 16 Inside #5Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#7 912.20' 962 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,003 cf Overall - 597 cf Embedded = 2,406 cf x 40.0% Voids

#8 912.70' 597 cf ADS_StormTech SC-740 - Isolator Row x 13 Inside #7Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#9 912.70' 44 cf 12.0" Round Pipe Storage Storm Tech - Str #2L= 55.4' S= 0.0044 '/'

11,764 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 2,281 0 0916.43 2,281 9,649 9,649

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 1,266 0 0916.43 1,266 5,355 5,355

Page 56: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 005 Rainfall=3.24"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 33HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 829 0 0916.43 829 3,507 3,507

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 710 0 0916.43 710 3,003 3,003

Device Routing Invert Outlet Devices#1 Primary 912.14' 18.0" Round Culvert

L= 137.9' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.14' / 911.82' S= 0.0023 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 1.77 sf

#2 Device 1 912.20' 0.7" Vert. Underdrain C= 0.600 #3 Device 1 912.70' 6.5" Vert. Orifice C= 0.600 #4 Device 1 915.05' 6.0" W x 7.0" H Vert. Window C= 0.600 #5 Device 1 916.20' 3.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s) #6 Tertiary 916.98' 4.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=1.45 cfs @ 12.25 hrs HW=914.63' (Free Discharge)1=Culvert (Passes 1.45 cfs of 8.10 cfs potential flow)

2=Underdrain (Orifice Controls 0.02 cfs @ 7.46 fps)3=Orifice (Orifice Controls 1.43 cfs @ 6.21 fps)4=Window ( Controls 0.00 cfs)5=Sharp-Crested Rectangular Weir ( Controls 0.00 cfs)

Tertiary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.20' (Free Discharge)6=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 57: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 005 Rainfall=3.24"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 34HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 7: Underground StormTech System

InflowOutflowPrimaryTertiary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

7

6

5

4

3

2

1

0

Inflow Area=1.982 acPeak Elev=914.63'Storage=7,854 cf

6.69 cfs

1.45 cfs1.45 cfs

0.00 cfs

Page 58: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 010 Rainfall=3.74"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 35HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 1: Str #4 Trib Area

Runoff = 3.97 cfs @ 12.01 hrs, Volume= 0.229 af, Depth= 2.87"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 010 Rainfall=3.74"

Area (ac) CN Description* 0.631 98 Pavement* 0.329 80 Grass

0.960 92 Weighted Average0.329 34.27% Pervious Area0.631 65.73% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 1: Str #4 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

4

3

2

1

0

Type II 24-hrDublin 010 Rainfall=3.74"

Runoff Area=0.960 acRunoff Volume=0.229 af

Runoff Depth=2.87"Tc=10.0 min

CN=92

3.97 cfs

Page 59: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 010 Rainfall=3.74"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 36HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 2: Surface Ponding @ Str #4

Inflow Area = 0.960 ac, 65.73% Impervious, Inflow Depth = 2.87" for Dublin 010 eventInflow = 3.97 cfs @ 12.01 hrs, Volume= 0.229 afOutflow = 5.16 cfs @ 12.17 hrs, Volume= 0.229 af, Atten= 0%, Lag= 9.4 minPrimary = 5.16 cfs @ 12.17 hrs, Volume= 0.246 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 917.96' @ 12.12 hrs Surf.Area= 2,497 sf Storage= 975 cf

Plug-Flow detention time= (not calculated: outflow precedes inflow)Center-of-Mass det. time= 0.9 min ( 793.7 - 792.8 )

Volume Invert Avail.Storage Storage Description#1 917.20' 3,206 cf Surface Ponding (Prismatic) Listed below (Recalc)#2 913.52' 26 cf 3.00'D x 3.70'H Str #5

3,232 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.20 4 0 0918.60 4,576 3,206 3,206

Device Routing Invert Outlet Devices#1 Primary 913.52' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 913.52' / 913.28' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=2.70 cfs @ 12.17 hrs HW=917.81' TW=917.22' (Dynamic Tailwater)1=Culvert (Outlet Controls 2.70 cfs @ 3.44 fps)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=913.52' TW=912.94' (Dynamic Tailwater)2=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 60: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 010 Rainfall=3.74"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 37HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 2: Surface Ponding @ Str #4

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

5

4

3

2

1

0

Inflow Area=0.960 acPeak Elev=917.96'

Storage=975 cf3.97 cfs

5.16 cfs5.16 cfs

0.00 cfs

Page 61: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 010 Rainfall=3.74"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 38HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 3: Str #2 Trib Area

Runoff = 1.58 cfs @ 12.01 hrs, Volume= 0.091 af, Depth= 2.77"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 010 Rainfall=3.74"

Area (ac) CN Description* 0.149 80 Grass* 0.244 98 Pavement

0.393 91 Weighted Average0.149 37.91% Pervious Area0.244 62.09% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 3: Str #2 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs) 1

0

Type II 24-hrDublin 010 Rainfall=3.74"

Runoff Area=0.393 acRunoff Volume=0.091 af

Runoff Depth=2.77"Tc=10.0 min

CN=91

1.58 cfs

Page 62: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 010 Rainfall=3.74"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 39HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

Inflow Area = 1.353 ac, 64.67% Impervious, Inflow Depth = 2.98" for Dublin 010 eventInflow = 5.55 cfs @ 12.15 hrs, Volume= 0.336 afOutflow = 5.35 cfs @ 12.02 hrs, Volume= 0.336 af, Atten= 4%, Lag= 0.0 minPrimary = 5.35 cfs @ 12.02 hrs, Volume= 0.336 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 917.90' @ 12.19 hrs Surf.Area= 823 sf Storage= 331 cf

Plug-Flow detention time= 1.9 min calculated for 0.336 af (100% of inflow)Center-of-Mass det. time= 1.9 min ( 793.2 - 791.3 )

Volume Invert Avail.Storage Storage Description#1 912.94' 100 cf 3.00'D x 4.73'H Str #2 x 3#2 912.94' 61 cf 12.0" Round Pipe Storage Str #2 - Str #3

L= 77.9' S= 0.0044 '/'#3 913.28' 42 cf 3.00'D x 5.95'H Str #3#4 913.28' 44 cf 12.0" Round Pipe Storage Str #3 - Str #4

L= 55.4' S= 0.0040 '/'#5 917.67' 1,466 cf Str #2 Surface Ponding (Prismatic) Listed below (Recalc)

1,713 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.67 4 0 0918.60 3,148 1,466 1,466

Device Routing Invert Outlet Devices#1 Primary 912.94' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.94' / 912.70' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Device 1 912.94' 10.5" Vert. Orifice Plate C= 0.600 #3 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=5.22 cfs @ 12.02 hrs HW=917.62' TW=914.38' (Dynamic Tailwater)1=Culvert (Passes 5.22 cfs of 6.31 cfs potential flow)

2=Orifice Plate (Orifice Controls 5.22 cfs @ 8.67 fps)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.94' TW=912.20' (Dynamic Tailwater)3=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 63: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 010 Rainfall=3.74"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 40HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

6

5

4

3

2

1

0

Inflow Area=1.353 acPeak Elev=917.90'

Storage=331 cf

5.55 cfs

5.35 cfs5.35 cfs

0.00 cfs

Page 64: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 010 Rainfall=3.74"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 41HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 5: Roof Top Trib Area

Runoff = 1.64 cfs @ 11.95 hrs, Volume= 0.089 af, Depth= 3.51"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 010 Rainfall=3.74"

Area (ac) CN Description0.306 98 Roofs, HSG D0.306 100.00% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)

5.0 Direct Entry,

Subcatchment 5: Roof Top Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

1

0

Type II 24-hrDublin 010 Rainfall=3.74"

Runoff Area=0.306 acRunoff Volume=0.089 af

Runoff Depth=3.51"Tc=5.0 min

CN=98

1.64 cfs

Page 65: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 010 Rainfall=3.74"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 42HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 6: Storm Tech Trib Area

Runoff = 1.30 cfs @ 12.01 hrs, Volume= 0.075 af, Depth= 2.77"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 010 Rainfall=3.74"

Area (ac) CN Description* 0.118 80 Grass* 0.205 98 Pavement

0.323 91 Weighted Average0.118 36.53% Pervious Area0.205 63.47% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 6: Storm Tech Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

1

0

Type II 24-hrDublin 010 Rainfall=3.74"

Runoff Area=0.323 acRunoff Volume=0.075 af

Runoff Depth=2.77"Tc=10.0 min

CN=91

1.30 cfs

Page 66: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 010 Rainfall=3.74"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 43HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 7: Underground StormTech System

Inflow Area = 1.982 ac, 69.93% Impervious, Inflow Depth = 3.03" for Dublin 010 eventInflow = 7.92 cfs @ 12.00 hrs, Volume= 0.500 afOutflow = 2.27 cfs @ 12.26 hrs, Volume= 0.487 af, Atten= 71%, Lag= 15.8 minPrimary = 2.27 cfs @ 12.26 hrs, Volume= 0.487 afTertiary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 915.50' @ 12.26 hrs Surf.Area= 5,086 sf Storage= 9,873 cf

Plug-Flow detention time= 141.2 min calculated for 0.486 af (97% of inflow)Center-of-Mass det. time= 126.4 min ( 912.1 - 785.8 )

Volume Invert Avail.Storage Storage Description#1 912.20' 2,830 cf Perimeter Stone (Prismatic) Listed below (Recalc)

9,649 cf Overall - 2,573 cf Embedded = 7,076 cf x 40.0% Voids#2 912.70' 2,573 cf ADS_StormTech SC-740 4 Rows of 14 units x 56 Inside #1

Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap4 Rows of 14 Chambers

#3 912.20' 1,628 cf Perimeter Stone (Prismatic) Listed below (Recalc)5,355 cf Overall - 1,286 cf Embedded = 4,069 cf x 40.0% Voids

#4 912.70' 1,286 cf ADS_StormTech SC-740 1 Row of 14 units x 28 Inside #3Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap2 Rows of 14 Chambers

#5 912.20' 1,109 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,507 cf Overall - 735 cf Embedded = 2,772 cf x 40.0% Voids

#6 912.70' 735 cf ADS_StormTech SC-740 - Isolator Row x 16 Inside #5Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#7 912.20' 962 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,003 cf Overall - 597 cf Embedded = 2,406 cf x 40.0% Voids

#8 912.70' 597 cf ADS_StormTech SC-740 - Isolator Row x 13 Inside #7Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#9 912.70' 44 cf 12.0" Round Pipe Storage Storm Tech - Str #2L= 55.4' S= 0.0044 '/'

11,764 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 2,281 0 0916.43 2,281 9,649 9,649

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 1,266 0 0916.43 1,266 5,355 5,355

Page 67: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 010 Rainfall=3.74"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 44HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 829 0 0916.43 829 3,507 3,507

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 710 0 0916.43 710 3,003 3,003

Device Routing Invert Outlet Devices#1 Primary 912.14' 18.0" Round Culvert

L= 137.9' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.14' / 911.82' S= 0.0023 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 1.77 sf

#2 Device 1 912.20' 0.7" Vert. Underdrain C= 0.600 #3 Device 1 912.70' 6.5" Vert. Orifice C= 0.600 #4 Device 1 915.05' 6.0" W x 7.0" H Vert. Window C= 0.600 #5 Device 1 916.20' 3.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s) #6 Tertiary 916.98' 4.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=2.23 cfs @ 12.26 hrs HW=915.48' (Free Discharge)1=Culvert (Passes 2.23 cfs of 10.39 cfs potential flow)

2=Underdrain (Orifice Controls 0.02 cfs @ 8.68 fps)3=Orifice (Orifice Controls 1.76 cfs @ 7.62 fps)4=Window (Orifice Controls 0.45 cfs @ 2.10 fps)5=Sharp-Crested Rectangular Weir ( Controls 0.00 cfs)

Tertiary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.20' (Free Discharge)6=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 68: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 010 Rainfall=3.74"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 45HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 7: Underground StormTech System

InflowOutflowPrimaryTertiary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

8

7

6

5

4

3

2

1

0

Inflow Area=1.982 acPeak Elev=915.50'Storage=9,873 cf

7.92 cfs

2.27 cfs2.27 cfs

0.00 cfs

Page 69: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 025 Rainfall=4.44"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 46HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 1: Str #4 Trib Area

Runoff = 4.85 cfs @ 12.01 hrs, Volume= 0.284 af, Depth= 3.54"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 025 Rainfall=4.44"

Area (ac) CN Description* 0.631 98 Pavement* 0.329 80 Grass

0.960 92 Weighted Average0.329 34.27% Pervious Area0.631 65.73% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 1: Str #4 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

5

4

3

2

1

0

Type II 24-hrDublin 025 Rainfall=4.44"

Runoff Area=0.960 acRunoff Volume=0.284 af

Runoff Depth=3.54"Tc=10.0 min

CN=92

4.85 cfs

Page 70: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 025 Rainfall=4.44"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 47HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 2: Surface Ponding @ Str #4

Inflow Area = 0.960 ac, 65.73% Impervious, Inflow Depth = 3.54" for Dublin 025 eventInflow = 4.85 cfs @ 12.01 hrs, Volume= 0.284 afOutflow = 4.35 cfs @ 11.94 hrs, Volume= 0.286 af, Atten= 10%, Lag= 0.0 minPrimary = 4.58 cfs @ 11.98 hrs, Volume= 0.375 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 918.18' @ 12.12 hrs Surf.Area= 3,220 sf Storage= 1,606 cf

Plug-Flow detention time= (not calculated: outflow precedes inflow)Center-of-Mass det. time= 2.8 min ( 789.8 - 786.9 )

Volume Invert Avail.Storage Storage Description#1 917.20' 3,206 cf Surface Ponding (Prismatic) Listed below (Recalc)#2 913.52' 26 cf 3.00'D x 3.70'H Str #5

3,232 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.20 4 0 0918.60 4,576 3,206 3,206

Device Routing Invert Outlet Devices#1 Primary 913.52' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 913.52' / 913.28' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=0.00 cfs @ 11.98 hrs HW=917.38' TW=917.77' (Dynamic Tailwater)1=Culvert ( Controls 0.00 cfs)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=913.52' TW=912.94' (Dynamic Tailwater)2=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 71: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 025 Rainfall=4.44"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 48HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 2: Surface Ponding @ Str #4

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

5

4

3

2

1

0

Inflow Area=0.960 acPeak Elev=918.18'

Storage=1,606 cf

4.85 cfs

4.35 cfs4.58 cfs

0.00 cfs

Page 72: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 025 Rainfall=4.44"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 49HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 3: Str #2 Trib Area

Runoff = 1.94 cfs @ 12.01 hrs, Volume= 0.113 af, Depth= 3.44"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 025 Rainfall=4.44"

Area (ac) CN Description* 0.149 80 Grass* 0.244 98 Pavement

0.393 91 Weighted Average0.149 37.91% Pervious Area0.244 62.09% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 3: Str #2 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

2

1

0

Type II 24-hrDublin 025 Rainfall=4.44"

Runoff Area=0.393 acRunoff Volume=0.113 af

Runoff Depth=3.44"Tc=10.0 min

CN=91

1.94 cfs

Page 73: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 025 Rainfall=4.44"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 50HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

Inflow Area = 1.353 ac, 64.67% Impervious, Inflow Depth = 4.33" for Dublin 025 eventInflow = 6.44 cfs @ 11.98 hrs, Volume= 0.488 afOutflow = 5.51 cfs @ 11.97 hrs, Volume= 0.488 af, Atten= 14%, Lag= 0.0 minPrimary = 5.51 cfs @ 11.97 hrs, Volume= 0.488 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 917.94' @ 12.50 hrs Surf.Area= 942 sf Storage= 361 cf

Plug-Flow detention time= 2.5 min calculated for 0.488 af (100% of inflow)Center-of-Mass det. time= 1.8 min ( 783.2 - 781.4 )

Volume Invert Avail.Storage Storage Description#1 912.94' 100 cf 3.00'D x 4.73'H Str #2 x 3#2 912.94' 61 cf 12.0" Round Pipe Storage Str #2 - Str #3

L= 77.9' S= 0.0044 '/'#3 913.28' 42 cf 3.00'D x 5.95'H Str #3#4 913.28' 44 cf 12.0" Round Pipe Storage Str #3 - Str #4

L= 55.4' S= 0.0040 '/'#5 917.67' 1,466 cf Str #2 Surface Ponding (Prismatic) Listed below (Recalc)

1,713 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.67 4 0 0918.60 3,148 1,466 1,466

Device Routing Invert Outlet Devices#1 Primary 912.94' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.94' / 912.70' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Device 1 912.94' 10.5" Vert. Orifice Plate C= 0.600 #3 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=5.31 cfs @ 11.97 hrs HW=917.74' TW=914.38' (Dynamic Tailwater)1=Culvert (Passes 5.31 cfs of 6.42 cfs potential flow)

2=Orifice Plate (Orifice Controls 5.31 cfs @ 8.83 fps)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.94' TW=912.20' (Dynamic Tailwater)3=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 74: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 025 Rainfall=4.44"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 51HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

7

6

5

4

3

2

1

0

Inflow Area=1.353 acPeak Elev=917.94'

Storage=361 cf

6.44 cfs

5.51 cfs5.51 cfs

0.00 cfs

Page 75: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 025 Rainfall=4.44"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 52HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 5: Roof Top Trib Area

Runoff = 1.95 cfs @ 11.95 hrs, Volume= 0.107 af, Depth= 4.20"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 025 Rainfall=4.44"

Area (ac) CN Description0.306 98 Roofs, HSG D0.306 100.00% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)

5.0 Direct Entry,

Subcatchment 5: Roof Top Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

2

1

0

Type II 24-hrDublin 025 Rainfall=4.44"

Runoff Area=0.306 acRunoff Volume=0.107 af

Runoff Depth=4.20"Tc=5.0 min

CN=98

1.95 cfs

Page 76: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 025 Rainfall=4.44"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 53HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 6: Storm Tech Trib Area

Runoff = 1.60 cfs @ 12.01 hrs, Volume= 0.093 af, Depth= 3.44"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 025 Rainfall=4.44"

Area (ac) CN Description* 0.118 80 Grass* 0.205 98 Pavement

0.323 91 Weighted Average0.118 36.53% Pervious Area0.205 63.47% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 6: Storm Tech Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs) 1

0

Type II 24-hrDublin 025 Rainfall=4.44"

Runoff Area=0.323 acRunoff Volume=0.093 af

Runoff Depth=3.44"Tc=10.0 min

CN=91

1.60 cfs

Page 77: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 025 Rainfall=4.44"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 54HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 7: Underground StormTech System

Inflow Area = 1.982 ac, 69.93% Impervious, Inflow Depth = 4.17" for Dublin 025 eventInflow = 8.86 cfs @ 11.97 hrs, Volume= 0.688 afOutflow = 3.59 cfs @ 12.50 hrs, Volume= 0.675 af, Atten= 60%, Lag= 32.0 minPrimary = 3.59 cfs @ 12.50 hrs, Volume= 0.675 afTertiary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 916.27' @ 12.51 hrs Surf.Area= 5,086 sf Storage= 11,446 cf

Plug-Flow detention time= 118.9 min calculated for 0.675 af (98% of inflow)Center-of-Mass det. time= 106.8 min ( 885.1 - 778.4 )

Volume Invert Avail.Storage Storage Description#1 912.20' 2,830 cf Perimeter Stone (Prismatic) Listed below (Recalc)

9,649 cf Overall - 2,573 cf Embedded = 7,076 cf x 40.0% Voids#2 912.70' 2,573 cf ADS_StormTech SC-740 4 Rows of 14 units x 56 Inside #1

Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap4 Rows of 14 Chambers

#3 912.20' 1,628 cf Perimeter Stone (Prismatic) Listed below (Recalc)5,355 cf Overall - 1,286 cf Embedded = 4,069 cf x 40.0% Voids

#4 912.70' 1,286 cf ADS_StormTech SC-740 1 Row of 14 units x 28 Inside #3Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap2 Rows of 14 Chambers

#5 912.20' 1,109 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,507 cf Overall - 735 cf Embedded = 2,772 cf x 40.0% Voids

#6 912.70' 735 cf ADS_StormTech SC-740 - Isolator Row x 16 Inside #5Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#7 912.20' 962 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,003 cf Overall - 597 cf Embedded = 2,406 cf x 40.0% Voids

#8 912.70' 597 cf ADS_StormTech SC-740 - Isolator Row x 13 Inside #7Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#9 912.70' 44 cf 12.0" Round Pipe Storage Storm Tech - Str #2L= 55.4' S= 0.0044 '/'

11,764 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 2,281 0 0916.43 2,281 9,649 9,649

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 1,266 0 0916.43 1,266 5,355 5,355

Page 78: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 025 Rainfall=4.44"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 55HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 829 0 0916.43 829 3,507 3,507

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 710 0 0916.43 710 3,003 3,003

Device Routing Invert Outlet Devices#1 Primary 912.14' 18.0" Round Culvert

L= 137.9' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.14' / 911.82' S= 0.0023 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 1.77 sf

#2 Device 1 912.20' 0.7" Vert. Underdrain C= 0.600 #3 Device 1 912.70' 6.5" Vert. Orifice C= 0.600 #4 Device 1 915.05' 6.0" W x 7.0" H Vert. Window C= 0.600 #5 Device 1 916.20' 3.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s) #6 Tertiary 916.98' 4.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=3.57 cfs @ 12.50 hrs HW=916.27' (Free Discharge)1=Culvert (Passes 3.57 cfs of 12.15 cfs potential flow)

2=Underdrain (Orifice Controls 0.03 cfs @ 9.68 fps)3=Orifice (Orifice Controls 2.02 cfs @ 8.75 fps)4=Window (Orifice Controls 1.35 cfs @ 4.62 fps)5=Sharp-Crested Rectangular Weir (Weir Controls 0.18 cfs @ 0.87 fps)

Tertiary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.20' (Free Discharge)6=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 79: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 025 Rainfall=4.44"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 56HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 7: Underground StormTech System

InflowOutflowPrimaryTertiary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

9

8

7

6

5

4

3

2

1

0

Inflow Area=1.982 acPeak Elev=916.27'Storage=11,446 cf

8.86 cfs

3.59 cfs3.59 cfs

0.00 cfs

Page 80: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 050 Rainfall=5.02"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 57HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 1: Str #4 Trib Area

Runoff = 5.57 cfs @ 12.01 hrs, Volume= 0.329 af, Depth= 4.11"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 050 Rainfall=5.02"

Area (ac) CN Description* 0.631 98 Pavement* 0.329 80 Grass

0.960 92 Weighted Average0.329 34.27% Pervious Area0.631 65.73% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 1: Str #4 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

6

5

4

3

2

1

0

Type II 24-hrDublin 050 Rainfall=5.02"

Runoff Area=0.960 acRunoff Volume=0.329 af

Runoff Depth=4.11"Tc=10.0 min

CN=92

5.57 cfs

Page 81: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 050 Rainfall=5.02"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 58HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 2: Surface Ponding @ Str #4

Inflow Area = 0.960 ac, 65.73% Impervious, Inflow Depth = 4.11" for Dublin 050 eventInflow = 5.57 cfs @ 12.01 hrs, Volume= 0.329 afOutflow = 4.81 cfs @ 11.94 hrs, Volume= 0.329 af, Atten= 14%, Lag= 0.0 minPrimary = 4.57 cfs @ 11.95 hrs, Volume= 0.342 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 918.30' @ 12.14 hrs Surf.Area= 3,616 sf Storage= 2,020 cf

Plug-Flow detention time= (not calculated: outflow precedes inflow)Center-of-Mass det. time= 2.8 min ( 785.8 - 782.9 )

Volume Invert Avail.Storage Storage Description#1 917.20' 3,206 cf Surface Ponding (Prismatic) Listed below (Recalc)#2 913.52' 26 cf 3.00'D x 3.70'H Str #5

3,232 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.20 4 0 0918.60 4,576 3,206 3,206

Device Routing Invert Outlet Devices#1 Primary 913.52' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 913.52' / 913.28' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=0.00 cfs @ 11.95 hrs HW=917.37' TW=917.84' (Dynamic Tailwater)1=Culvert ( Controls 0.00 cfs)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=913.52' TW=912.94' (Dynamic Tailwater)2=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 82: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 050 Rainfall=5.02"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 59HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 2: Surface Ponding @ Str #4

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

6

5

4

3

2

1

0

Inflow Area=0.960 acPeak Elev=918.30'

Storage=2,020 cf

5.57 cfs

4.81 cfs

4.57 cfs

0.00 cfs

Page 83: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 050 Rainfall=5.02"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 60HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 3: Str #2 Trib Area

Runoff = 2.24 cfs @ 12.01 hrs, Volume= 0.131 af, Depth= 4.00"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 050 Rainfall=5.02"

Area (ac) CN Description* 0.149 80 Grass* 0.244 98 Pavement

0.393 91 Weighted Average0.149 37.91% Pervious Area0.244 62.09% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 3: Str #2 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

2

1

0

Type II 24-hrDublin 050 Rainfall=5.02"

Runoff Area=0.393 acRunoff Volume=0.131 af

Runoff Depth=4.00"Tc=10.0 min

CN=91

2.24 cfs

Page 84: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 050 Rainfall=5.02"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 61HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

Inflow Area = 1.353 ac, 64.67% Impervious, Inflow Depth = 4.19" for Dublin 050 eventInflow = 6.48 cfs @ 11.96 hrs, Volume= 0.473 afOutflow = 5.47 cfs @ 11.96 hrs, Volume= 0.473 af, Atten= 16%, Lag= 0.4 minPrimary = 5.47 cfs @ 11.96 hrs, Volume= 0.473 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 918.01' @ 12.01 hrs Surf.Area= 1,189 sf Storage= 438 cf

Plug-Flow detention time= 1.8 min calculated for 0.472 af (100% of inflow)Center-of-Mass det. time= 1.8 min ( 786.2 - 784.4 )

Volume Invert Avail.Storage Storage Description#1 912.94' 100 cf 3.00'D x 4.73'H Str #2 x 3#2 912.94' 61 cf 12.0" Round Pipe Storage Str #2 - Str #3

L= 77.9' S= 0.0044 '/'#3 913.28' 42 cf 3.00'D x 5.95'H Str #3#4 913.28' 44 cf 12.0" Round Pipe Storage Str #3 - Str #4

L= 55.4' S= 0.0040 '/'#5 917.67' 1,466 cf Str #2 Surface Ponding (Prismatic) Listed below (Recalc)

1,713 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.67 4 0 0918.60 3,148 1,466 1,466

Device Routing Invert Outlet Devices#1 Primary 912.94' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.94' / 912.70' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Device 1 912.94' 10.5" Vert. Orifice Plate C= 0.600 #3 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=5.31 cfs @ 11.96 hrs HW=917.92' TW=914.56' (Dynamic Tailwater)1=Culvert (Passes 5.31 cfs of 6.42 cfs potential flow)

2=Orifice Plate (Orifice Controls 5.31 cfs @ 8.83 fps)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.94' TW=912.20' (Dynamic Tailwater)3=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 85: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 050 Rainfall=5.02"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 62HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

7

6

5

4

3

2

1

0

Inflow Area=1.353 acPeak Elev=918.01'

Storage=438 cf

6.48 cfs

5.47 cfs5.47 cfs

0.00 cfs

Page 86: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 050 Rainfall=5.02"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 63HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 5: Roof Top Trib Area

Runoff = 2.21 cfs @ 11.95 hrs, Volume= 0.122 af, Depth= 4.78"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 050 Rainfall=5.02"

Area (ac) CN Description0.306 98 Roofs, HSG D0.306 100.00% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)

5.0 Direct Entry,

Subcatchment 5: Roof Top Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

2

1

0

Type II 24-hrDublin 050 Rainfall=5.02"

Runoff Area=0.306 acRunoff Volume=0.122 af

Runoff Depth=4.78"Tc=5.0 min

CN=98

2.21 cfs

Page 87: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 050 Rainfall=5.02"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 64HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 6: Storm Tech Trib Area

Runoff = 1.84 cfs @ 12.01 hrs, Volume= 0.108 af, Depth= 4.00"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 050 Rainfall=5.02"

Area (ac) CN Description* 0.118 80 Grass* 0.205 98 Pavement

0.323 91 Weighted Average0.118 36.53% Pervious Area0.205 63.47% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 6: Storm Tech Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

2

1

0

Type II 24-hrDublin 050 Rainfall=5.02"

Runoff Area=0.323 acRunoff Volume=0.108 af

Runoff Depth=4.00"Tc=10.0 min

CN=91

1.84 cfs

Page 88: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 050 Rainfall=5.02"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 65HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 7: Underground StormTech System

Inflow Area = 1.982 ac, 69.93% Impervious, Inflow Depth = 4.25" for Dublin 050 eventInflow = 9.30 cfs @ 11.97 hrs, Volume= 0.702 afOutflow = 3.42 cfs @ 12.35 hrs, Volume= 0.689 af, Atten= 63%, Lag= 23.1 minPrimary = 3.42 cfs @ 12.35 hrs, Volume= 0.689 afTertiary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 916.24' @ 12.35 hrs Surf.Area= 5,086 sf Storage= 11,369 cf

Plug-Flow detention time= 118.2 min calculated for 0.688 af (98% of inflow)Center-of-Mass det. time= 107.6 min ( 886.4 - 778.8 )

Volume Invert Avail.Storage Storage Description#1 912.20' 2,830 cf Perimeter Stone (Prismatic) Listed below (Recalc)

9,649 cf Overall - 2,573 cf Embedded = 7,076 cf x 40.0% Voids#2 912.70' 2,573 cf ADS_StormTech SC-740 4 Rows of 14 units x 56 Inside #1

Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap4 Rows of 14 Chambers

#3 912.20' 1,628 cf Perimeter Stone (Prismatic) Listed below (Recalc)5,355 cf Overall - 1,286 cf Embedded = 4,069 cf x 40.0% Voids

#4 912.70' 1,286 cf ADS_StormTech SC-740 1 Row of 14 units x 28 Inside #3Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap2 Rows of 14 Chambers

#5 912.20' 1,109 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,507 cf Overall - 735 cf Embedded = 2,772 cf x 40.0% Voids

#6 912.70' 735 cf ADS_StormTech SC-740 - Isolator Row x 16 Inside #5Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#7 912.20' 962 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,003 cf Overall - 597 cf Embedded = 2,406 cf x 40.0% Voids

#8 912.70' 597 cf ADS_StormTech SC-740 - Isolator Row x 13 Inside #7Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#9 912.70' 44 cf 12.0" Round Pipe Storage Storm Tech - Str #2L= 55.4' S= 0.0044 '/'

11,764 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 2,281 0 0916.43 2,281 9,649 9,649

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 1,266 0 0916.43 1,266 5,355 5,355

Page 89: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 050 Rainfall=5.02"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 66HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 829 0 0916.43 829 3,507 3,507

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 710 0 0916.43 710 3,003 3,003

Device Routing Invert Outlet Devices#1 Primary 912.14' 18.0" Round Culvert

L= 137.9' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.14' / 911.82' S= 0.0023 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 1.77 sf

#2 Device 1 912.20' 0.7" Vert. Underdrain C= 0.600 #3 Device 1 912.70' 6.5" Vert. Orifice C= 0.600 #4 Device 1 915.05' 6.0" W x 7.0" H Vert. Window C= 0.600 #5 Device 1 916.20' 3.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s) #6 Tertiary 916.98' 4.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=3.42 cfs @ 12.35 hrs HW=916.24' (Free Discharge)1=Culvert (Passes 3.42 cfs of 12.08 cfs potential flow)

2=Underdrain (Orifice Controls 0.03 cfs @ 9.64 fps)3=Orifice (Orifice Controls 2.00 cfs @ 8.70 fps)4=Window (Orifice Controls 1.32 cfs @ 4.53 fps)5=Sharp-Crested Rectangular Weir (Weir Controls 0.07 cfs @ 0.62 fps)

Tertiary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.20' (Free Discharge)6=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 90: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 050 Rainfall=5.02"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 67HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 7: Underground StormTech System

InflowOutflowPrimaryTertiary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

10

9

8

7

6

5

4

3

2

1

0

Inflow Area=1.982 acPeak Elev=916.24'Storage=11,369 cf

9.30 cfs

3.42 cfs3.42 cfs

0.00 cfs

Page 91: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 68HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 1: Str #4 Trib Area

Runoff = 6.33 cfs @ 12.01 hrs, Volume= 0.376 af, Depth= 4.71"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 100 Rainfall=5.63"

Area (ac) CN Description* 0.631 98 Pavement* 0.329 80 Grass

0.960 92 Weighted Average0.329 34.27% Pervious Area0.631 65.73% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 1: Str #4 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

7

6

5

4

3

2

1

0

Type II 24-hrDublin 100 Rainfall=5.63"

Runoff Area=0.960 acRunoff Volume=0.376 af

Runoff Depth=4.71"Tc=10.0 min

CN=92

6.33 cfs

Page 92: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 69HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 2: Surface Ponding @ Str #4

Inflow Area = 0.960 ac, 65.73% Impervious, Inflow Depth = 4.71" for Dublin 100 eventInflow = 6.33 cfs @ 12.01 hrs, Volume= 0.376 afOutflow = 4.28 cfs @ 11.89 hrs, Volume= 0.378 af, Atten= 32%, Lag= 0.0 minPrimary = 4.17 cfs @ 11.92 hrs, Volume= 0.394 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 918.51' @ 12.16 hrs Surf.Area= 4,290 sf Storage= 2,835 cf

Plug-Flow detention time= (not calculated: outflow precedes inflow)Center-of-Mass det. time= 4.4 min ( 783.8 - 779.4 )

Volume Invert Avail.Storage Storage Description#1 917.20' 3,206 cf Surface Ponding (Prismatic) Listed below (Recalc)#2 913.52' 26 cf 3.00'D x 3.70'H Str #5

3,232 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.20 4 0 0918.60 4,576 3,206 3,206

Device Routing Invert Outlet Devices#1 Primary 913.52' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 913.52' / 913.28' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=0.00 cfs @ 11.92 hrs HW=917.30' TW=917.73' (Dynamic Tailwater)1=Culvert ( Controls 0.00 cfs)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=913.52' TW=912.94' (Dynamic Tailwater)2=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 93: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 70HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 2: Surface Ponding @ Str #4

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

7

6

5

4

3

2

1

0

Inflow Area=0.960 acPeak Elev=918.51'

Storage=2,835 cf

6.33 cfs

4.28 cfs4.17 cfs

0.00 cfs

Page 94: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 71HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 3: Str #2 Trib Area

Runoff = 2.55 cfs @ 12.01 hrs, Volume= 0.151 af, Depth= 4.60"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 100 Rainfall=5.63"

Area (ac) CN Description* 0.149 80 Grass* 0.244 98 Pavement

0.393 91 Weighted Average0.149 37.91% Pervious Area0.244 62.09% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 3: Str #2 Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

2

1

0

Type II 24-hrDublin 100 Rainfall=5.63"

Runoff Area=0.393 acRunoff Volume=0.151 af

Runoff Depth=4.60"Tc=10.0 min

CN=91

2.55 cfs

Page 95: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 72HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

Inflow Area = 1.353 ac, 64.67% Impervious, Inflow Depth = 4.83" for Dublin 100 eventInflow = 6.25 cfs @ 11.93 hrs, Volume= 0.545 afOutflow = 5.44 cfs @ 11.92 hrs, Volume= 0.545 af, Atten= 13%, Lag= 0.0 minPrimary = 5.44 cfs @ 11.92 hrs, Volume= 0.545 afSecondary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 917.98' @ 12.13 hrs Surf.Area= 1,082 sf Storage= 402 cf

Plug-Flow detention time= 1.8 min calculated for 0.544 af (100% of inflow)Center-of-Mass det. time= 1.8 min ( 783.4 - 781.7 )

Volume Invert Avail.Storage Storage Description#1 912.94' 100 cf 3.00'D x 4.73'H Str #2 x 3#2 912.94' 61 cf 12.0" Round Pipe Storage Str #2 - Str #3

L= 77.9' S= 0.0044 '/'#3 913.28' 42 cf 3.00'D x 5.95'H Str #3#4 913.28' 44 cf 12.0" Round Pipe Storage Str #3 - Str #4

L= 55.4' S= 0.0040 '/'#5 917.67' 1,466 cf Str #2 Surface Ponding (Prismatic) Listed below (Recalc)

1,713 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

917.67 4 0 0918.60 3,148 1,466 1,466

Device Routing Invert Outlet Devices#1 Primary 912.94' 12.0" Round Culvert

L= 55.4' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.94' / 912.70' S= 0.0043 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 0.79 sf

#2 Device 1 912.94' 10.5" Vert. Orifice Plate C= 0.600 #3 Secondary 918.60' 5.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=5.24 cfs @ 11.92 hrs HW=917.73' TW=914.46' (Dynamic Tailwater)1=Culvert (Passes 5.24 cfs of 6.34 cfs potential flow)

2=Orifice Plate (Orifice Controls 5.24 cfs @ 8.71 fps)

Secondary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.94' TW=912.20' (Dynamic Tailwater)3=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 96: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 73HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 4: Surface Ponding & Pipe Storage 2 @ Str #2

InflowOutflowPrimarySecondary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

7

6

5

4

3

2

1

0

Inflow Area=1.353 acPeak Elev=917.98'

Storage=402 cf

6.25 cfs

5.44 cfs5.44 cfs

0.00 cfs

Page 97: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 74HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 5: Roof Top Trib Area

Runoff = 2.48 cfs @ 11.95 hrs, Volume= 0.138 af, Depth= 5.39"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 100 Rainfall=5.63"

Area (ac) CN Description0.306 98 Roofs, HSG D0.306 100.00% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)

5.0 Direct Entry,

Subcatchment 5: Roof Top Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

2

1

0

Type II 24-hrDublin 100 Rainfall=5.63"

Runoff Area=0.306 acRunoff Volume=0.138 af

Runoff Depth=5.39"Tc=5.0 min

CN=98

2.48 cfs

Page 98: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 75HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Subcatchment 6: Storm Tech Trib Area

Runoff = 2.10 cfs @ 12.01 hrs, Volume= 0.124 af, Depth= 4.60"

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-48.00 hrs, dt= 0.05 hrsType II 24-hr Dublin 100 Rainfall=5.63"

Area (ac) CN Description* 0.118 80 Grass* 0.205 98 Pavement

0.323 91 Weighted Average0.118 36.53% Pervious Area0.205 63.47% Impervious Area

Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)10.0 Direct Entry, Storm Sewer Minimum

Subcatchment 6: Storm Tech Trib Area

Runoff

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

2

1

0

Type II 24-hrDublin 100 Rainfall=5.63"

Runoff Area=0.323 acRunoff Volume=0.124 af

Runoff Depth=4.60"Tc=10.0 min

CN=91

2.10 cfs

Page 99: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 76HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Summary for Pond 7: Underground StormTech System

Inflow Area = 1.982 ac, 69.93% Impervious, Inflow Depth = 4.88" for Dublin 100 eventInflow = 9.44 cfs @ 11.95 hrs, Volume= 0.806 afOutflow = 4.26 cfs @ 12.26 hrs, Volume= 0.793 af, Atten= 55%, Lag= 18.3 minPrimary = 4.26 cfs @ 12.26 hrs, Volume= 0.793 afTertiary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af

Routing by Dyn-Stor-Ind method, Time Span= 0.00-48.00 hrs, dt= 0.05 hrs / 3Peak Elev= 916.38' @ 12.26 hrs Surf.Area= 5,086 sf Storage= 11,666 cf

Plug-Flow detention time= 110.8 min calculated for 0.793 af (98% of inflow)Center-of-Mass det. time= 100.2 min ( 876.4 - 776.2 )

Volume Invert Avail.Storage Storage Description#1 912.20' 2,830 cf Perimeter Stone (Prismatic) Listed below (Recalc)

9,649 cf Overall - 2,573 cf Embedded = 7,076 cf x 40.0% Voids#2 912.70' 2,573 cf ADS_StormTech SC-740 4 Rows of 14 units x 56 Inside #1

Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap4 Rows of 14 Chambers

#3 912.20' 1,628 cf Perimeter Stone (Prismatic) Listed below (Recalc)5,355 cf Overall - 1,286 cf Embedded = 4,069 cf x 40.0% Voids

#4 912.70' 1,286 cf ADS_StormTech SC-740 1 Row of 14 units x 28 Inside #3Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap2 Rows of 14 Chambers

#5 912.20' 1,109 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,507 cf Overall - 735 cf Embedded = 2,772 cf x 40.0% Voids

#6 912.70' 735 cf ADS_StormTech SC-740 - Isolator Row x 16 Inside #5Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#7 912.20' 962 cf Perimeter Stone - Isolator Row (Prismatic) Listed below (Recalc)3,003 cf Overall - 597 cf Embedded = 2,406 cf x 40.0% Voids

#8 912.70' 597 cf ADS_StormTech SC-740 - Isolator Row x 13 Inside #7Effective Size= 44.6"W x 30.0"H => 6.45 sf x 7.12'L = 45.9 cfOverall Size= 51.0"W x 30.0"H x 7.56'L with 0.44' Overlap

#9 912.70' 44 cf 12.0" Round Pipe Storage Storm Tech - Str #2L= 55.4' S= 0.0044 '/'

11,764 cf Total Available Storage

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 2,281 0 0916.43 2,281 9,649 9,649

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 1,266 0 0916.43 1,266 5,355 5,355

Page 100: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 77HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 829 0 0916.43 829 3,507 3,507

Elevation Surf.Area Inc.Store Cum.Store(feet) (sq-ft) (cubic-feet) (cubic-feet)

912.20 710 0 0916.43 710 3,003 3,003

Device Routing Invert Outlet Devices#1 Primary 912.14' 18.0" Round Culvert

L= 137.9' RCP, square edge headwall, Ke= 0.500 Inlet / Outlet Invert= 912.14' / 911.82' S= 0.0023 '/' Cc= 0.900 n= 0.013 Concrete pipe, bends & connections, Flow Area= 1.77 sf

#2 Device 1 912.20' 0.7" Vert. Underdrain C= 0.600 #3 Device 1 912.70' 6.5" Vert. Orifice C= 0.600 #4 Device 1 915.05' 6.0" W x 7.0" H Vert. Window C= 0.600 #5 Device 1 916.20' 3.0' long Sharp-Crested Rectangular Weir 2 End Contraction(s) #6 Tertiary 916.98' 4.0' long x 1.0' breadth Broad-Crested Rectangular Weir

Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.50 3.00 Coef. (English) 2.69 2.72 2.75 2.85 2.98 3.08 3.20 3.28 3.31 3.30 3.31 3.32

Primary OutFlow Max=4.24 cfs @ 12.26 hrs HW=916.38' (Free Discharge)1=Culvert (Passes 4.24 cfs of 12.37 cfs potential flow)

2=Underdrain (Orifice Controls 0.03 cfs @ 9.81 fps)3=Orifice (Orifice Controls 2.05 cfs @ 8.89 fps)4=Window (Orifice Controls 1.43 cfs @ 4.89 fps)5=Sharp-Crested Rectangular Weir (Weir Controls 0.74 cfs @ 1.39 fps)

Tertiary OutFlow Max=0.00 cfs @ 0.00 hrs HW=912.20' (Free Discharge)6=Broad-Crested Rectangular Weir ( Controls 0.00 cfs)

Page 101: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

Page 78HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Pond 7: Underground StormTech System

InflowOutflowPrimaryTertiary

Hydrograph

Time (hours)484644424038363432302826242220181614121086420

Flo

w (

cfs)

10

9

8

7

6

5

4

3

2

1

0

Inflow Area=1.982 acPeak Elev=916.38'Storage=11,666 cf

9.44 cfs

4.26 cfs4.26 cfs

0.00 cfs

Page 102: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

APPENDIX E

WATER QUALITY CALCULATIONS

Page 103: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Crtown Mercedes - New DevelopmentNPDES Water Quality Requirements

New Development WQv = (C * P * A) / 12Redevelopment Development WQv = ((C * P * A) / 12) * .2

Answer: Land Use Acre % Total

Impervious 0.122 100%WQv = Pervious 0.000 0%C = Total Area 0.122P =A =

Water Quality Volume WQv = ((C x P x A) / 12)in. Ac.

ac.ft. 0.0068 = 0.89 x 0.75 x 0.122 / 12cu. ft. 296

3. Determine Runoff CoefficientWater Quality Volume Required C = 0.858 * i ^3 - 0.78 * i^2 + 0.774 * i + 0.04

TWQv = 296 CF

Drainage area (acres)

Volume

1. Is this project New Development or Redevelopment? 2. Determine Percent ImperviousNew Development

Water Quality Volume (ac.ft.)Runoff Coefficient.75-in precipitation depth (inch)

Page 104: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Crown Mercedes - RedevelopmentNPDES Water Quality Requirements

New Development WQv = (C * P * A) / 12Redevelopment Development WQv = ((C * P * A) / 12) * .2

Answer: Land Use Acre % Total

Impervious 1.424 70%WQv = Pervious 0.608 30%C = Total Area 2.032P =A =

Water Quality Volume WQv = ((C x P x A) / 12)in. Ac.

ac.ft. 0.0628 = 0.49 x 0.75 x 2.032 / 12cu. ft. 2,736

3. Determine Runoff CoefficientWater Quality Volume Required C = 0.858 * i ^3 - 0.78 * i^2 + 0.774 * i + 0.04

TWQv = 2,736 CF

20% treatment for RedevelopmentTWQv = 547 CF

Drainage area (acres)

Volume

1. Is this project New Development or Redevelopment? 2. Determine Percent ImperviousRedevelopment

Water Quality Volume (ac.ft.)Runoff Coefficient.75-in precipitation depth (inch)

Page 105: STORMWATER MANAGEMENT REPORT CROWN MERCEDES · DDR Continental LP. APN: 273-007383. The Manor at Craughwell Village Condominium APN: \⠀䴀甀氀琀椀瀀氀攀尩 ZONING:

Type II 24-hr Dublin 100 Rainfall=5.63"17-0001-837 Crown Mercedes Printed 6/8/2017Prepared by Advanced Civil Design

HydroCAD® 10.00-17 s/n 09322 © 2016 HydroCAD Software Solutions LLC

Hydrograph for Pond 7: Underground StormTech System

Time(hours)

Inflow(cfs)

Storage(cubic-feet)

Elevation(feet)

Outflow(cfs)

Primary(cfs)

Tertiary(cfs)

0.00 0.00 1,017 912.70 0.01 0.01 0.001.00 0.00 986 912.68 0.01 0.01 0.002.00 0.00 955 912.67 0.01 0.01 0.003.00 0.00 924 912.65 0.01 0.01 0.004.00 0.00 894 912.64 0.01 0.01 0.005.00 0.00 865 912.63 0.01 0.01 0.006.00 0.00 836 912.61 0.01 0.01 0.007.00 0.00 808 912.60 0.01 0.01 0.008.00 0.00 780 912.58 0.01 0.01 0.009.00 0.00 752 912.57 0.01 0.01 0.00

10.00 0.00 726 912.56 0.01 0.01 0.0011.00 0.00 699 912.54 0.01 0.01 0.0012.00 0.00 674 912.53 0.01 0.01 0.0013.00 0.00 649 912.52 0.01 0.01 0.0014.00 0.00 624 912.51 0.01 0.01 0.0015.00 0.00 600 912.49 0.01 0.01 0.0016.00 0.00 576 912.48 0.01 0.01 0.0017.00 0.00 553 912.47 0.01 0.01 0.0018.00 0.00 530 912.46 0.01 0.01 0.0019.00 0.00 508 912.45 0.01 0.01 0.0020.00 0.00 487 912.44 0.01 0.01 0.0021.00 0.00 466 912.43 0.01 0.01 0.0022.00 0.00 446 912.42 0.01 0.01 0.0023.00 0.00 426 912.41 0.01 0.01 0.0024.00 0.00 406 912.40 0.01 0.01 0.0025.00 0.00 387 912.39 0.01 0.01 0.0026.00 0.00 369 912.38 0.01 0.01 0.0027.00 0.00 351 912.37 0.00 0.00 0.0028.00 0.00 334 912.36 0.00 0.00 0.0029.00 0.00 317 912.36 0.00 0.00 0.0030.00 0.00 301 912.35 0.00 0.00 0.0031.00 0.00 285 912.34 0.00 0.00 0.0032.00 0.00 270 912.33 0.00 0.00 0.0033.00 0.00 255 912.33 0.00 0.00 0.0034.00 0.00 241 912.32 0.00 0.00 0.0035.00 0.00 228 912.31 0.00 0.00 0.0036.00 0.00 215 912.31 0.00 0.00 0.0037.00 0.00 202 912.30 0.00 0.00 0.0038.00 0.00 190 912.29 0.00 0.00 0.0039.00 0.00 179 912.29 0.00 0.00 0.0040.00 0.00 168 912.28 0.00 0.00 0.0041.00 0.00 157 912.28 0.00 0.00 0.0042.00 0.00 147 912.27 0.00 0.00 0.0043.00 0.00 138 912.27 0.00 0.00 0.0044.00 0.00 129 912.26 0.00 0.00 0.0045.00 0.00 121 912.26 0.00 0.00 0.0046.00 0.00 113 912.26 0.00 0.00 0.0047.00 0.00 106 912.25 0.00 0.00 0.0048.00 0.00 99 912.25 0.00 0.00 0.00

cechelberry
Callout
Begin drawdown
cechelberry
Highlight
cechelberry
Callout
At 1/3 the drawdown time, over 1/2 the volume remains.
cechelberry
Callout
End drawdown