Faulkner / Haynes & Associates, Inc.2 Faulkner Haynes, Inc.
ABOUT FAULKNER HAYNES
Mission Statement
The mission of Faulkner Haynes, Inc. is to be the premier provider of commercial HVAC and power
quality products in the Carolinas.
Faulkner Haynes, Inc. is a sales driven company, however service is our final product.
Faulkner Haynes is a manufacturer’s representative serving the commercial and industrial heating, ventilation and air conditioning (HVAC) markets of the Carolinas. With a combination of high quality manufacturers and exceptional technical salespeople we strive to provide Engineers, Contractors and Owners/End users: • Unmatched product expertise • Technical design assistance • Reliable budget estimates • Accurate quotations • Dependable submittals • Professional project management • Unparalleled technical support and start-up assistance • Fully Stocked HVAC warehouse
CHARLOTTE, NC2221 Park Road, Suite 200Charlotte, NC 28203-6100(P) 704.343.9577 (F) 704.343.9592
GREENSBORO, NC1500 Pinecroft Rd, Suite 121Greensboro, NC 27407(P) 336.299.3006 (F) 336.299.3417
WILMINGTON, NC3809 Peachtree Avenue, Suite 201Wilmington, NC 28403-1403(P) 910.251.9155 (F) 910.251.9176
COLUMBIA, SC1630 Augusta RoadWest Columbia, SC 29169-5630(P) 803.926.9229 (F) 803.926.3639
GREENVILLE, SC100 Whitsett StreetGreenville, SC 29601(P) 864.329.0372 (F) 864.329.0376
CHARLESTON, SC4365 Dorchester Road, Suite 107Charleston, SC 29405-8422(P) 843.884.3554 (F) 843.884.3094
FAULKNER HAYNES, INC. HEADQUARTERS3400 Yonkers Road, Suite 110, Raleigh NC 27604
(P) 919.781.8840 (F) 919.787.8765
www.FaulknerHaynes.com 3www.FaulknerHaynes.com
TABLE OF CONTENTS
Air Distribution Cross-Reference Sheet....................................................................................................................4
Tips, Tips, and More Tips..................................................................................................................................................5-7
Air DistributionPerforated Ceiling Supply Diffusers..............................................................................................................10Perforated Ceiling Return Diffusers...............................................................................................................11Louvered Faced Ceiling Diffusers...................................................................................................................12Square Cone Diffusers............................................................................................................................................13Square Plaque Diffusers........................................................................................................................................14Supply Registers..........................................................................................................................................................15Return Grilles & Registers.....................................................................................................................................16Filter Grilles......................................................................................................................................................................17Egg-Crate Returns.....................................................................................................................................................18Plenum Slot Diffusers..............................................................................................................................................19Round Cone Supply Diffusers...........................................................................................................................20Spiral Registers.............................................................................................................................................................21Ceiling Diffuser & Return Accessories.................................................................................................22-24Single Duct Terminal Units..................................................................................................................................25
FansCentrifugal Roof Exhauster..................................................................................................................................27Cabinet Fans...........................................................................................................................................................28-31Vibration Isolation Kits.............................................................................................................................................32Gravity Ventilators......................................................................................................................................................33Roof / Wall Caps.........................................................................................................................................................34Curbs & Rails..................................................................................................................................................................35
Fan Accessories.........................................................................................................................................................................36
DampersCAD / DM / Access Door....................................................................................................................................38Radiation Dampers....................................................................................................................................................39Fire Dampers.................................................................................................................................................................40
LouversExtruded Aluminum Louver.................................................................................................................................41
Ductless Mini-SplitsWall-Mounted Ductless Mini-Splits.................................................................................................43 & 46Ceiling Cassette Ductless Mini-Splits..............................................................................................44 & 47Horizontal Ducted Mini-Splits...............................................................................................................45 & 48Multi-Zone Mini-Splits.................................................................................................................................49 & 50Mini-Split Controls & Accessories..........................................................................................................51-55
Vibration Isolation and Seismic Restraints..................................................................................................57-58
Variable Frequency Drives................................................................................................................................................60
Ductwork & Accessories.....................................................................................................................................................61
Gas Fire Heaters...............................................................................................................................................................62-64
Line Card.........................................................................................................................................................................................66
Faulkner / Haynes & Associates, Inc.4 Faulkner Haynes, Inc.
TITUS NAILOR METAL-AIRE PRICE TUTTLE & BAILEY CARNES
300RS 61DV V4004 520S T64 RSDBV
350RL 6145H RH 530L T70D RSABH
PCS 4320CB 7000 PDC PV SPFB
T700L-AF 61DGD DGDF STG/BF A980WF RGCAD
PAS 4320L 7500 PDF PP SPAB
PAR 4360 7600R PDDR PR SPRB
PXP 4302 SPRTB PFRF PTL SPHB
TMS RNS 5700 SCD 1200/1300 SFTB
TDC 6500 5500 SMD MSR SKTA
OMNI UNI 5850 SPD T-1100 SFPA
50F 61EC CC1 80 CRE RAEAC
TRM DFA TBPF PFS SMF KXFAA
350RLF 61FBL45 SRAF 530FF T70DFB RSABD
50FF 61FEL CC1S-FB-6 80FF CB8500FB RAPAF
8RF 61FPL RP-FB 10FLB PGFB RSFA
TBDI 5710I PDI10 TBD410 SVPSI-075 DARB-B-R
ML 5000 6600 SDS 6X (1,2,5) CH
TBD-FR 5575 N/A TBD2 N/A 5575WB
7600-FRS 4113 SPRTBFRS 10FR N/A N/A
PESV P3001 500/400TH SPV SDVP AVCC-CX
DESV D3001 500/400TH SDV SDVD AVCC-CX
PEDV W/ATT P3230 400DD DPS DDVP ADCD-CF
DTQP 35NE 400FVI FDV FPV ASEG
DTQS 35SE 400FCI FDC FPC ACFG
ML38 5075 6575 SDS75 62 CHCB
ML39 5010 6510 SDS100 72 CHFB
MPI38 5375 I 6075BPI SDAI75 DPI62 CXPA6-1
MPI39 5310 I 6100BPI SDAI10 DPT72 CXPA8-1
AG-75 4275 D3 VCR RON KXMB
TMR RNR 3100 RCDE P3 SSEA
AIR DISTRIBUTION CROSS-REFERENCE
www.FaulknerHaynes.com 5www.FaulknerHaynes.com
TIPS, TIPS, AND MORE TIPS
• Air Change Rate per Hour: Total Volume x ACH/60 = CFM
• Air Change Frequency in Minutes: Total Volume/AC Frequency in Minutes = CFM
• Heating Load = 24 BTUH/sq. ft. Insulated Building
• Heating Load = 40 BTUH/sq. ft. Non-Insulated Building
• Combustion Air: 4 CFM OA/1,000 BTUH input
• Gas Pressure: 1 PSI = 28‖ WC (water column) = 2.04” Hg (Mercury)
Electricity
• Watts = Volts x Amps
• 1 HP (motor) = .746 KW (operating energy)
• 5 HP x .746 KW/HP x 3413 BTUH/KW = 12,700 BTUH = 1 Ton of Cooling
• KW (3 phase) = Volts x Amps x 1.732 x Power Factor/1000
• KW (1 phase) = Volts x Amps x Power Factor/10000
• Efficiency = 746 x Output Horsepower (HP)/Input Watts
• HP (3 phase) = Volts x Amps x 1.732 x Eff. x Power Factor/746
• HP (1 phase) = Volts x Amps x Eff. X Power Factor/746
Swimming Pool Design
• Must determine evaporation rate: What water temp & air temp? – Norm: 80° pool water temp & 82° air temperature
• 4 - 6 air changes per hour for pools + 2 additional air changes for pools with spectator facilities
• 0.5 CFM of outside air (OA)/sq. ft. pool and deck area or 15 CFM/person of OA, whichever is greater
• Contact factory rep when OA requirements greater than 15% of unit CFM
• Must have means of heat rejection for summertime usage, i.e. air cooled condenser
• Maintain pool at .05 to .15 negative pressure with exhaust fan and try to place exhaust grille directly over whirlpool
• Supply air should be blown across full width of all windows
• Do not direct supply air over pool surface
• Return air grille 10-15 feet above pool floor level as far away from any whirlpools as possible
• Need separate plastic, inline pump for pool water to be circulated through dehumidifier for pool heating
• *Vapor barrier on warm (inside) portion of outside wall and ceiling
• Pool water must be maintained at pH level between 7.2 and 7.6
• Do not store pool chemicals in mechanical room
• Skylights not recommended
• Need 2 - 3 CFM/sq. ft. for glass to minimize glass condensation
CAMBRIDGE ENGINEERING
DANFOSS
Fuel Comparisons
• Natural Gas - 1,000,000 BTUH = 10 Therms or 1000 Cubic Ft.
• Propane Gas - 1,000,000 BTUH = 46 Lb. or 10.88 Gallons
• No 2 Fuel Oil - 1,000,000 BTUH = 7.14 Gallons
• Electricity - 1,000,000 BTUH = 293 KW
DESERT AIRE
EBTRON
• Best Installed Accuracy
• Low Airflow Capability
• Volumetric or Mass Airflow Measurement
• Long-term Stability
• “Plug and Play” Operation
• Intuitive User Interface
• Waterproof Sensor Assembly
• FEP Plenum Rated Cables
Faulkner / Haynes & Associates, Inc.6 Faulkner Haynes, Inc.
TIPS, TIPS, AND MORE TIPS
NEPTRONICS
Humidification
• 1 lb water = 7000 grains
• Self Generating Steam Electrode type
• In-duct or Space Atomizing type
• 12,000 BTUH = 1 ton of cooling
• 1 MBH = 1000 BTUH
• Sensible Heat: Measured in dry bulb temperatures
• Sensible Cooling/Heating (BTUH) = CFM x 1.08 x Temp Difference
• Latent Heat: Measure in wet bulb temperatures and related to change in humidity ratio
• Total Cooling (BTUH) = CFM x 4.5 x Enthalpy Difference
LIEBERT PRIHODA
• Cooling (BTUH) = GPM x 500 x Temperature Difference
• Pump BHP = GPM x FT x Specific Gravity/3960 x Pump Efficiency
• Pump BHP = GPM x PSI x Specific Gravity/1713 x Pump Efficiency
• Head in Feet = 2.31 PSIG
MASON INDUSTRIES
Seismic Guidelines
• Seismic restraints are required for the following items when suspended by individual hangers greater than 12” in length from supporting structure
• Ductwork: Ducts greater than 6 sq. ft. rectangular or 28” round to be braced 30’ transverse and 60’ longitudinal
• Piping: Gas or fuel pipe 1” diameter and larger to be braced 20’ transverse and 40’ longitudinal
• In boiler and mechanical rooms with piping 1¼” ID and larger and in other areas with piping 2½” ID or greater to be braced 40’ transverse and 80’ longitudinal
• Installation Time: Approx. 30 min to 1 hour per location ( 2 minutes per foot of pipe or duct)
TITUS
• Secondary air movement is room air entrained by supply air
• 700 FPM outlet velocity required for heating out of ceiling diffuser
Air Distribution
• 1.0 - 1.5 CFM of supply air/sq. ft. of foor area for comfort cooling
• Vertical Throw is the maximum distances below the ceiling of the air pattern at terminal velocities of 100, 75, and 50 FPM
• Drop is downward supply of air movement at a specific throw
• Spread is the maximum width of air pattern at terminal velocities of 100, 75 and 50 FPM
• Secondary air movement is room air entrained by supply air
• 700 FPM outlet velocity required for heating out of ceiling diffuser
Heat Load
• Transmission heat gains: BTUH =”U” factor x sq. ft. x Temperature Difference
• Solar heat gains: BTUH = Solar Heat Gain Factor x sq. ft. of glass
• People Load (Sensible): BTUH = Solar Heat Gain Factor x 250 BTUH/person
• People Load (Latent): BTUH = Solar Heat Gain Factor x 350 BTUH/person
• Lighting Load: BTUH = 3 watts/sq. ft. x floor areas (sq. ft.) x 3.413
• 15,000 BTUH = 1 ton of heat rejection for cooling tower
• 3.0 GPM/ton for condenser water
• Condenser water temperature range: 85 EWT to 95 LWT
POTTORFF
Fire Dampers & Louvers
• Type A: Return air and transfer air
• Type B: Low pressure supply air
• Type C: High pressure supply air
• All fire dampers are required to have sleeves per NFPA
• Static Fire Dampers were tested without air movement in the ductwork
• Dynamic Fire Dampers were tested with air movement. They should be used
• Louver Free Area Velocity = CFM/free area
• Normal louver sizing based on 700 FPM through free area of louver
RAYWALL
Electric Heat
• 1KW = 1000 watts
• 1KW = 3413 BTUH
www.FaulknerHaynes.com 7www.FaulknerHaynes.com
TIPS, TIPS, AND MORE TIPS
VULCAIN
Refrigerant Monitors
• ASHRAE Standard 15-1994 states that a refrigerant monitor must be installed in a refrigerating machinery room
• Sampling point should be 18” above finished floor
• Sampling point should be positioned between refrigerant system and a room exhaust
• Multiple refrigerants can be detected by a singe controller with refrigerant specific sensors
YOUNG REGULATOR
Bowden Cable Control System should be used
• Above Sheetrock ceilings
• Above HEPA filter ceilings
• Above special architectural ceilings
• Above secured prison cells
• In underground ductwork
• In high atriums
VIBRO-ACOUSTICS
• Centrifugal fan noise maximizes in 3rd octave band (250 hz)
• Sound power (generation from the fan) and sound pressure (received by the ear) are measured in dB(decibels)
– Ten (10) times logarithm of the ration of a given power to a reference power
– In sound the current reference power is 10^-12 watts
• NC (Noise Criteria) curves based on different dB levels at different octave bands
• With two (2) sound sources of equal dBs, the equiva-lent dB is the original + 3 dB
– i.e. 60 dB + 60 dB = 63 dB
• With two sound sources of unequal dBs, if the differ-ence is 10dB or more, use higher dB
– i.e. 60 dB + 60 dB = 63 dB
• With two sound sources of unequal dBs, if the differ-ence is 10dB or more, use higher dB
– i.e. 70 dB + 60 dB = 70 dB
• Sones: a single number method to predict loudness levels, usually for small fans
TWIN CITY FANS
Fan Laws
• Law #1: CFM varies Directly with RPM
• Law #2: Static Pressure varies with the Square of the RPM
• Law #2: Static Pressure varies with the Square of the RPM
Fan Classes
• Class 1 Fans: up to 4.5” pressure
• Class 2 Fans: up to 7” - 8”: pressure, heavier gauges & larger shafts than Class 1
• Class 3 Fans: above 7” - 8” pressure, still heavier gauges & larger shafts than Class 2
Roof Curbs
• Top of curb 8” above roof, common to use 12” high roof curb
• Three types: Straight sided, canted and raised cant.
• Outside dimension (OD) of curb should be 2” - 3” less than Inside dimension (ID) of equipment sitting on
• Curb to allow for flashing material to be brought over top
• Wood nailer used as means of securing equipment to the curb
Kitchen Exhaust
• Make-up fan inlet shall be at least 10’ away from exhaust fan outlet
• Kitchen exhaust duct: welded 16 gauge and shall have velocity over 1500 FPM
• Kitchen exhaust hoods: Wall mount: 100 FPM through canopy
• Island mount: 150 FPM through canopy
• 6” overhang on all sides beyond cooking battery
• Kitchen exhaust fans shall be upblast and outlet shall be at least 40” above roof
TITUS CONTINUED
• Cooling tower water range: 95 EWT to 85 LWT
• 2.4 GPM/ton for chiller evaporator
• Chiller temperature range: 55 EWT to 45 LWT
• Chilled water coils temperature range: 45 EWT to 55 LWT
Faulkner / Haynes & Associates, Inc.8 Faulkner Haynes, Inc.
TERMS AND CONDITIONS
Prices: Prices are FOB shipping point. Shipments via air or other specific methods will be subject to additional freight charges. Prices are subject to change without notice.
Terms of Payment: All orders are either COD or bank approved checks unless prior credit has been approved. Credit terms are net (30) days from date of invoice unless otherwise indicated. A service charge of 1½ percent per month will be assessed each month after the initial 30 day period has expired until payment is received. In the event of non-payment, the buyer agrees to bear the expense of all legal proceedings plus any reasonable attorney fees.
Venue: The contract shall be governed by and construed in accordance with the laws of the state of North Carolina.
Taxes: Taxes are not included in the sales price. Any taxes, if applicable and imposed by any present or future local, state or federal agency must be paid by the Buyer.
Warranty: No express or implied warranties as to the goods sold extends to the buyer other than the manufacturer’s warranty.
Claims: The responsibility of the ceases upon delivery of material in good order to the carrier. As all goods are shipped at buyer’s risk, any claims for damage or shortage or loss in transit must be filled by the buyer against the transportation company. (We will assist the buyer in any reasonable way possible in the filing and collection for any claim for damages and/or losses while in transit.) Claims against shortage will not be considered unless made within 60 days after receipt of goods.
Return Of Goods: Goods may not be returned except by permission of a representative of Faulkner Haynes, Inc., and when so returned, shall be subject to a restocking fee. No goods may be returned after 90 days.
www.FaulknerHaynes.com10
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• The PAR series diffusers are return diffusers that match the PCS series
• Can be adjusted before or after installation
• 51% free area perforated face
• The PCS perforated ceiling diffuser, Supply, has curved blade deflectors mounted in the neck
Product Details
• Discharge pattern can be adjusted from horizontal to vertical
MODEL PCS
Neck Dia Mounting Face Size Max CFM¹ Steel Price Each
Aluminum Price Each Damper Insulated
backpan
6”
Lay-In
12’” x 12 “ 235 $29 N/A $7
$12
6”
24” x 24”
235 $30 $33 $7
8” 397 $30 $33 $8
10” 567 $30 $33 $8
12” 754 $30 $33 $9
14” 941 $30 $33 $18
16” 1171 $35 $38
Note: 1 - CFM based on NC ≤ 35
Border Type 3 (Lay-In)
24 x 24” Backpan(Shaded Sizes in Table)
NominalDuct Size D
D minus 1/8”
Ceiling Module Minus 1/4”
Ceiling Module Size
Non-24 x 24”Backpan
PERFORATED CEILING DIFFUSERS, SUPPLYMODEL PCS
www.FaulknerHaynes.com 11
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• The PAR perforated return ceiling diffusers are round neck grilles also available with square necks
• Provides tight, uniform, horizontal blanket of air that protects the ceiling against smudging
• 51% free area perforated face
Product Details
MODEL PAR
Neck Size Mounting Face Size Max CFM¹ Steel Price Each
Aluminum Price Each Damper
6” dia
Lay-in
12” x 12” 195 $23 N/A $7
6” dia
24” x 24”
195 $23 $26 $7
8”dia 350 $23 $26 $8
10” dia 545 $23 $26 $8
12” dia 785 $23 $26 $9
14” dia 1070 $23 $26 $15
16” dia 1395 $31 $33 $20
10” x 22” 12” x 24” 1528 $23 N/A N/A
22” x 22” 24” x 24” 3361 $23 N/A N/A
Note: 1 - CFM based on maximum neck velocity of 1000 fpm and Ps drop of 0.10 in Wg
PERFORATED CEILING DIFFUSERS, RETURNModel PAR
Border Type 3 (Lay-In when D=Module size -2)
Border Type 3 (Lay-In for other duct sizes shown)
Nominal Duct Size D
NominalDuct Size D
D minus 1/8”
Ceiling Module minus 1/4”Ceiling Module Size
D minus 1/8”
Ceiling Module Minus 1/4”
Ceiling Module Size
www.FaulknerHaynes.com12
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• 4-way blow pattern
• Steel and aluminum construction
• Removable core from face of diffuser
• Cone and louvered face, high capacity
Product Details
See page 22 for square-to-round neck adapters.
• Opposed blade dampers and square to round transitions available
MODEL TDC
Model Neck Size Mounting Face Size Max CFM¹ SteelPrice Each
AluminumPrice Each Damper
TDC-6
6” x 6”
Surface/ Beveled
Duct + 5”
175 $16 N/A $8
9” x 9” 394 $20 N/A $9
12” x 12” 660 $28 N/A $12
15” x 15” 969 $36 N/A $17
TDC-3
6” x 6”
Lay-In 24”x24”
175 $26 $30 $8
9” x 9” 394 $30 $34 $9
12” x 12” 660 $37 $42 $12
15” x 15” 969 $46 $52 $17
18” x 18”
Note: 1 - CFM based on NC ≤ 35
LOUVERED FACE DIFFUSERSModel TDC
STEEL AND ALUMINUM CONSTRUCTION
Border Type 3 (Lay-In)
Ceiling Module
Ceiling Module minus 1/4”
2 1/8”
Duct sizeplus 1”
* A plus 5”
2 1/8”
7/8”
Border Type 6 (Beveled Drop Face)
www.FaulknerHaynes.com 13
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Excellent for variable air volume system
• Steel and aluminum construction • Uniform 360 discharge pattern
Product Details
• 3 concentric cones in all sizes
• Screwdriver adjustment of optional damper
MODEL TMS
Neck Size Mounting Face Size Max CFM¹ SteelPrice Each
AluminumPrice Each Damper Insulated
backpan
6”
Lay-In
12” x 12” 262 $19 N/A $7
$12
6”
24” x 24”
335 $29 $36 $7
8” 532 $29 $36 $8
10” 765 $29 $36 $8
12” 993 $29 $41 $9
14” 1285 $29 $41 $15
15” 1350 $31 $41 $20
Note: 1 - CFM based on NC ≤ 35
SQUARE CONE DIFFUSERSModel TMSSTEEL AND ALUMNUM CONSTRUCTION
TMS • Round Neck
Square Ceiling DiffusersSteel • High Performance
D-TMS-1.0 1-4-12
Border Type 3 (Lay-In) Full Face. For other border types, please see next page.
Border Type 3 (Lay-In) Panel Mount. For other border types, please see next page.
Ceiling Module A minus 1/4"
B minus 1/8"
Nominal Round Duct Size B
Ceiling Module A
E
D
C
Ceiling Module A
Nominal Round Duct Size B
Nominal Face Sizes F C D E
24 x 24 4, 5* 12 X 12 2 3/4 5 1 1/824 x 24 6, 7 12 X 12 3/4 3 1 1/824 x 24 8 12 x 12 3/4 3 1 1/8
Ceiling Module A
Ceiling Module A minus 1/4"
B minus 1/8"
Duct Size BNominal Round
F
E
C
D
Ceiling Module A
Nominal Round Duct Size B C D E
12 x 12 4, 5* 3 1/8 5 3/8 1 1/812 x 12 6, 7 1 1/8 3 3/8 1 1/812 x 12 8 1 1/4 3 1/2 1 1/820 x 20 4, 5* 2 3/4 6 3/8 1 1/420 x 20 6, 8, 10 3/4 4 3/8 1 1/424 x 24 6, 8 1 1/4 5 1 1/424 x 24 10, 12, 14, 15 1 3/8 5 1/8 1 1/4
* Adapter is provided for Sizes 4 & 5
* Adapter is provided for Sizes 4 & 5
Ceiling Module A
Ceiling Module A minus 1/4”
E
C
D
Nominal Round Duct Size B
B minus 1/8”
www.FaulknerHaynes.com14
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Removable core from diffuser
• Steel and aluminum construction
• Designed for architectural ceilings
• Uniform 360 horizontal air pattern
Product Details
• Provides excellent performance in VAV system
MODEL OMNI
Neck Size Mounting Face Size Max CFM¹ SteelPrice Each
AluminumPrice Each Damper Insulated
backpan
6”
Lay-In 24” x 24”
315 $33 $42 $7
$12
8” 420 $33 $42 $8
10” 545 $33 $42 $8
12” 785 $33 $42 $9
14” 1069 $35 $44 $15
15” 1227 $35 $44 $20
Note: 1 - CFM based on NC ≤ 35
SQUARE PLAQUE DIFFUSERSModel OMNI
STEEL AND ALUMINUM CONSTRUCTION
Ceiling Module A
Ceiling Module A minus 1/4”
Nominal Round Duct Size B
B minus 1/8”
E
C
1/4”
D
www.FaulknerHaynes.com 15
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Front blades parallel to the short dimension
• White finish
• Individually adjustable blades
• Available in 3/4 inch blade spacing
• Double deflection grilles
Product Details
• Opposed blade damper
SUPPLY REGISTERS300RS w/ OBD
Border Type 1 (Surface Mount)
Available Sizes (D” x D”)Border Type 1 is available in sizes 6” x 4” through 48” x 48” in 2” increments in one piece construction. Odd and fractional sizes are available at additional cost. Sizes larger than 48” x 48” are shipped in multiple sections with joining strips for field assembly.
Note: Wall or duct opening should be duct area + 1/8”. All dimensions are in inches.
D plus 1 3/4”
ScrewdriverSlot Operator For Optional Camper
1 1/4”1 1/4”
1 3/4”
3”
D minus 1/2”
Nominal Duct Size D”
9/16”3/4”
D minus 3/4”
6” 6”220
$18
$18
$20
$20
$20
$21
$21
$23
$23
$23
$25
$24
$27
$27
$25
$27
$29
$28
$30
$30
$30
$31
$33
$33
$33
$33
$35
$35
$36
$40
$43
$46
$52
$56
$63
$67
$74
$38
$18
$17
220
260
400
500
333
533
670
675
640
720
720
920
945
945
1045
1330
1500
2500
2500
1200
1200
1400
1440
1800
1600
720
750
750800
915
910
720
370
445
545
545
525
267
350
6”
4”
8”
8”
6”
6”
4”
8”
Neck NeckPriceMax CFM1 Max CFM1
Note: 1 - CF2M based on NC 30
Max CFM1PriceP riceNeck
10”
10”
6”
4”
8”
10”
12”
12”
6”
8”
10”
12”
6”
8”
10”
12”
8”
10”
12”
8”
10”
12”
6”
8”
6”
8”
10”
12”
10”
12”
8”
10”
12”
14”
14”
14”
16”
20”
20”
24”
24”
30”
36”
18”
W W HHHW
MODEL 300RS w/ OBD
www.FaulknerHaynes.com16
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Steel construction
• Blades parallel to the long dimension
Product Details
• Sidewall and lay-in applications available
6” 6” $6
$9
$9
$9
$9
$11
$10
$10
$10
$10
$12
$12
$13
$12
$13
$13
$14
$13
$14$14
$15
$18
$19
$18
$17
$17
$16
$25
$25
$45
$39
$39
$28
$24
$46
$21
$20
$20
$7
33
400
280
280
400
370
200
900
1400
1600
1500
600
1600
550
1000
775
835
1100
900
1250
800
1600178
240
800
133
267
450
550
600
900
500
700
750
100
1000
6”8”
8”
6”
8”
6”
8”
8”
Neck NeckPriceMax CFM1 Max CFM1
MODEL 350R
Note: 1 - CF2M based on NC 30
Max CFM1PriceP riceNeck
10”
10”
6”
6”
8”
10”
12”
12”
8”
8”
10”
10”
12”
10”
12”
12”
12”
12”8”
10”
12”14”
14”
14”
16”
16”
16”
16”
16”
20”
22”
***22”
10”
20”
*20”
**20”
20”
24”
24” 24”
30”
36”
$32
$35
$32
$52
$54
$22
1600
1600
900
1900
2200
2100
3200
3500
1100
Max CFM1 PriceNeck
18”
18”
18”
24”
18”
24”
28”
18”
*Surface Mount Filter Return Grille - 1” Filters by others. **Lay-in Filter Return Grille - 1” Filter by others. ***Lay-in Fixed Blade Return Grille - 24x24 Face.
See page 22 for square-to-round neck adapters.
FIXED BLADE RETURN GRILLESModel 350RL
Available Sizes (D” x D”)Border Type 1 is available in sizes 6” x 4” through 48” x 48” in 2” increments in one piece construction. Odd and fractional sizes are available at additional cost. Sizes larger than 48” x 48” are shipped in multiple sections with joining strips for field assembly.
Note: Wall or duct opening should be duct area + 1/8”. All dimensions are in inches.
W W W WH H H H
L
www.FaulknerHaynes.com 17
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• 24” x 24” face size only - accepts 20” x 20” x 1” filter “FILTER BY OTHERS”
• Steel construction
• 3/4 inch blade spacing
• 35” fixed deflection
Product Details
See page 22 for square-to-round neck adapters.
MODEL 350RLF1
Model Mount Neck Price
350RLF1-3 Lay-In 20x20 $52
Model 350RLF1
FIXED BLADE RETURN GRILLE, FILTERED(FILTERS BY OTHERS)
D PLUS 3 3/4”
3/4”
FASTENER
7/16” 1 1/4”
HINGE
NOMINAL DUCT SIZE (D)
Duct opening should be nominal duct size (d) plus 1/4”.
D PLUS 1/4”
2 5/32” FOR 1” FILTER3 3/16” FOR 2” FILTER
www.FaulknerHaynes.com18
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Surface mount and lay-in applications available
MODEL 50F
175 $14
$16
$18
$20
$49
$18
$29
311
486
700
2350
1070
2350
Surfacew/ OBD
Lay-In
6” x 6”
8” x 8”
10” x 10”
12” x 12”
22” x 22”
22” x 10”
22” x 22”
Model Neck Size Max CFM1 Price Each
Note: 1 - CFM based on max neck velocity of 700 fpm
• MRI compatible
• 1/2” x 1/2” x 1/2” aluminum border & core
Product Details
• Egg-crate matches appearance of parabolic lighting fixtures
2000*20” x 20” $49
* Lay-In Eggcrate Filter Grille – 1”Filter provided by others
See page 22 for square-to-round neck adapters.
Model 50FEGG-CRATE RETURN GRILLES
D plus 1 3/4”
1 1/4”3/16”
J
K
D minus 1/2”
Nominal Duct Size D”Available Sizes (D” x D”)
D minus 3/4”
www.FaulknerHaynes.com 19
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
PLENUM SLOT DIFFUSERS& FIRE RATED PLENUM SLOT DIFFUSERSModel TBDI-80
MODEL TBDI-80
Inlet SizeLength
8”
24”
48”
240$51
$51
$70
$70
375
480
750
10”
8”1” 2
*10”
Slot Width # Slots Max CFM1 Price Each
Note: 1 - CFM based on NC 35
<
• Insulated boot plenum
• Pattern controller for full 180 gradual adjustment
• Insulated modulinear diffuser
Product Details
Reference page 23 for plaster frames.
10”
*8”
$135
$115
*8” $100
*Fire Rated Plenum Slot Diffusers
Optional Internal Insulation(TBDI Models)
Optional T-bar Typical1/2”
8”
WL minus 1/4”
3/8” Typical
B
www.FaulknerHaynes.com20
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
ROUND CONCENTRIC DIFFUSERSModel TMR
• Excellent performance in variable air volume applications
• Horizontal discharge settings allows the diffuser to be adjusted for different flow rates.
• Uniform 360 discharge pattern
Product Details
See page 24 for available neck mounted volume dampers.
• Spring lock allows easy removal and replacement of the two inner cones
• Screwdriver adjustment of optional damper
MODEL TMR
Neck Size Mounting Face Size Max CFM¹ Price Damper
8”Surfacemount
orexposed
14.75” 425 $51 $8
10” 18.25” 635 $56 $8
12” 22” 850 $63 $9
Note: 1 - CFM based on NC ≤ 35
www.FaulknerHaynes.com 21
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Air scoop damper.
• Front blades parallel to short dimension.
• Double deflection grille with individual blades for airflow adjustments.
• The US300FS spiral grille is designed for installation to multiple diameter ducts without the need for a true curved frame.
Product Details
• Aluminum painted finish.
MODEL US300FS
Neck Fits Diameter Duct CFM (Max) Price
12” x 3” 10” to 36” 260 $62
12” x 6” 12 to 36” 400 $68
17” x 3” 10 to 36” 385 $69
21” x 3” 10 to 36” 450 $72
21” x 6” 12 to 36” 600 $81
25” x 3” 10 to 36” 525 $76
25” x 6” 12 to 36” 700 $86
Note: 1 - CFM based on NC ≤ 35
ALUMINUM UNIVERSAL DOUBLE DEFLECTIONSPIRAL GRILLES, SUPPLYModel US300FS
www.FaulknerHaynes.com22
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
SQUARE TO ROUND NECK ADAPTERSModel SRT
GALVANIZED AND BLACK FINISH
• 4 7/8” overall depth
• Square to round transitions slip fit over the square neck or register to permit installation to round or flex duct
Product Details
ROUND TO ROUND TRANSITIONS
$16
$18
$20
8”rd - 6”rd
10”rd - 8”rd
12”rd - 10”rd
Size Price
MODEL SRT
Neck Diameter Galvanized Finish
BlackFinish Neck Diameter Galvanized
FinishBlackFinish
6” x 6” 6” $5 N/A
20” x 20”
12” $12 $17
8” x 8”6” $5 $8 14” $12 $17
8” $5 N/A 16” $12 N/A
9” x 9” 8” $7 N/A
22” x 10”
6” $10 N/A
10” x 10”
6” $7 N/A 8” $11 N/A
8” $7 $9 10” $11 N/A
10” $7 N/A
22” x 22”
6” $13 $18
12” x 12”
6” $8 N/A 8” $13 $18
8” $8 $10 10” $13 $18
10” $8 N/A 12” $13 $18
12” $8 N/A 14” $13 $18
15” x 15” 14” $9 $12 16” $13 $18
20” x 20”
6” $12 N/A 18” $13 $22
8” $12 N/A 20” $13 $22
10” $12 N/A
www.FaulknerHaynes.com 23
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
A plus 1 1/4”Ceiling Opening = A plus 3/8”
Inside Opening = A-1”
A = Length of ceiling module
Dimensions are in inches
PERFORATED CEILING PANEL T-BAR PLASTER FRAME: Model PXP / TRM
• PXP perforated panels are designed for return or exhaust applications
• Installed by laying between T-bars
• Perforated panel has 3/16 inch diamter holes on 1/4 inch staggered centers
Product Details
• For use in plaster and sheet rock ceilings
Product Details
• Heavy gauge steel
• Lay-in style plaster frame that makes installation of GRD products easy
• Steel construction
T-Bar Module
T-Bar By Others1/4 TYP Perforated Face ReturnFront View
Overall Return Size = T-Bar Module - 1/4
Clips adjustable up and down to fit varying ceiling thicknesses
1/2 “ to 7/8”
3/16”
1 1/8”
FIBERGLASS BACK PAN (Titus Model# 72413401
Nominal Overall Price
24” x 24” 4” - 16” round neck $12
MODEL PXP
Nominal Price
24” x 12” $8
24” x 24” $10
MODEL TF-TBD
Nominal Steel Price
2-slot x 2’ $14
2-slot x 4’ $30
MODEL TRM
Nominal Steel Price
12” x 12” $13
24” x 12” $15
24” x 24” $18
www.FaulknerHaynes.com24
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
AIR BALANCING DEVICESModels AG-95
D-100
MODEL AG-95
$8
$9
$12
$17
6” x 6”
9” x 9”
12” x 12”
15” x 15”
Diameter Price
• Opposed blade
• Operating lever is accessible from the face side
• Even air distribution over diffuser neck opening
• Round dampers (Sliding Blade)
• Adjusts with screwdriver from the face side
• Separately mounted in the duct
Product Details
Product Details
• Steel construction
MODEL D-100
Diameter Price
6” $7
8” $8
10” $8
12” $9
14” $12
15” $14
www.FaulknerHaynes.com 25
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
HIGH PERFORMANCE SINGLE DUCT TERMINAL UNITS: Model DESV
• 22 gauge casing with slip and drive discharge connection
• Dual density insulation
• Multi point center averaging velocity center
• Control Enclosure with knock outs
Product Details
ACCESSORIES
115/24V & 277/24V Transformers $20
Model Inlet Size Min Max 1-Row Coil 2-Row Coil Terminal Unit Price
DESV 6” 66 800 $63 $90 $108
DESV 8” 132 900 $97 $112 $119
DESV 10” 221 1400 $98 $145 $137
DESV 12” 304 2000 $159 $177 $144
DESV 14” 439 3000 $197 $252 $182
www.FaulknerHaynes.com26
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
TWIN CITY FANS
www.FaulknerHaynes.com 27
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
TWIN CITY FANSDCRDCentrifugal Roof Exhauster, Direct Drive
• AMCA Air & Sound Licensed
• UL Listed-Standard 705
• Speed Controllable Motors
• Aluminum Bird screen
• Electrical Disconnect
• Shrouds feature a rolled bead edge for rigidity
• Backdraft Damper
• Aluminum Construction
Product Details
See page 35 for curbs.
See page 36 for speed controllers.
Size
085 1/8 1500
0
633
0.08
0.08
0.08
0.10
0.08
0.10
0.08
0.10
0.09
0.10
0.08
0.09
0.088.9
9.4
8.9
9.4
8.9
9.0
7.9
8.3
8.4
8.0
7.6
8.2
7.9
1328
592
1201
581
1168
522
985
457
768
381
496
291
0.100 0.125 0.250 0.375 0.500 0.625
1160120 1/8
MotorHP
CFMBHP SONE
CFMBHP SONE
CFMBHP SONE
CFMBHP SONE
CFMBHP SONE
CFMBHP SONE
CFMBHP SONE
RPM
Static Pressure (Inches W.G.)
DCRD
ModelDimensions (inches)
HPAverageShipping
Weight (lbs)
Curb SizeRequired
FanPrice
CurbPriceA B C D E G
085B 18.5 15.63 2.06 13.2 17.00 1/8 32 15½ x 15½ $257 $75
120B 27.88 22.38 3.63 22.00 20.00 14.50 1/8 50 18½ x 18½ $439 $86
www.FaulknerHaynes.com28
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
TWIN CITY FANSMODEL T081, T100, T150
Ceiling Exhaust Fan, Direct Drive
• Low profile
• The 100H series has a 6” round duct connector
• Single, impact-resistant centrifugal blower wheel
• 20 gauge galvanized steel housing
• UL listed for use over bathtubs and showers when connected to a GFCI branch circuit
Product Details
*Nominal voltage is 120VAC
*“H” and “V” refer to Horizontal and Vertical mounting
*Amps stated below rated at 60Hz
Notes:
See page 36 for fan accessories (speed controllers, inline adapters, radiation damper kits).
See page 34 for roof and wall caps accessories.
See page 32 for Vibration Isolators ($13/set).
Ps - Inches of Wg
Model 0.000 0.100 0.125 0.250 0.375 0.500 0.625 0.750 0.875 1.000 RPM AMPS WATTS Price
T081 HCFM 87 76 72 56 38
840 0.3 26.9 $69SONES 1.0 1.5 1.5 2.5 3.0
T100 HCFM 136 115 109 93 80 65 44 12
640 1.1 87 $123SONES 0.5 0.8 0.9 1.3 1.8 2.3 3.0 3.2
T150 HCFM 181 161 157 141 132 124 114 94 62
710 1.3 100 $130SONES 1.3 1.4 1.5 2.2 2.6 3.1 3.6 4.1 4.6
www.FaulknerHaynes.com 29
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
Ps - Inches of Wg
Model 0.000 0.100 0.125 0.250 0.375 0.500 0.625 0.750 0.875 1.000 RPM AMPS WATTS Price
T200 HCFM 231 214 210 196 186 177 165 144 113 51
740 1.8 127 $159SONES 1.6 1.8 1.7 2.3 2.9 3.5 4.1 4.9 5.3 5.3
T250 HCFM 272 261 259 250 242 233 218 201 165 99
830 2.1 166 $164SONES 2.1 2.3 2.2 2.9 3.3 3.9 4.4 4.8 5.5 5.8
T300 HCFM 312 309 308 303 296 287 273 254 219 125
905 2.3 212 $171SONES 2.6 2.9 3.0 3.4 3.6 3.9 4.4 4.7 5.0 5.5
TWIN CITY FANSMODEL T200, T250, T300Ceiling Exhaust Fan, Direct Drive
• Low profile
• The T200, T250, and T300 series have a 8” round duct connector
• Single, impact-resistant centrifugal blower wheel
• 20 gauge galvanized steel housing
• UL listed for use over bathtubs and showers when connected to a GFCI branch circuit
• Higher volume capacity compared with the T100 series
Product Details
*Nominal voltage is 120VAC
*“H” and “V” refer to Horizontal and Vertical mounting
*Amps stated below rated at 60Hz
Notes:
See page 36 for fan accessories (speed controllers, inline adapters, radiation damper kits).
See page 34 for roof and wall caps accessories.
See page 32 for Vibration Isolators ($13/set).
www.FaulknerHaynes.com30
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
TWIN CITY FANSMODEL T400, T500, T700
Ceiling Exhaust Fan, Direct Drive
• 434 CFM 2.3 Sones. (AMCA)
• 120V, 1.4 amps.
• 4-1/2” x 18-1/2” duct connector
• Painted white enamel steel grille
• Two impact-resistant centrifugal blower wheels
• Quiet automatic backdraft dampers
• Can be ducted horizontally or vertically. In-line ducting available with separate adapter
• Ceiling mount models available in 240V (add EX to model number) and 277V (add C to model number)
• Use Electronic Variable Speed Control to adjust blower speed and sound level (available separately)
Product Details
*Nominal voltage is 120VAC
*“H” and “V” refer to Horizontal and Vertical mounting
*Amps stated below rated at 60Hz
Notes:
See page 36 for fan accessories (speed controllers, inline adapters, radiation damper kits).
See page 34 for roof and wall caps accessories.
See page 32 for Vibration Isolators ($13/set).
Ps - Inches of Wg
Model 0.000 0.100 0.125 0.250 0.375 0.500 0.625 0.750 0.875 1.000 RPM AMPS WATTS Price
T400 HCFM 480 442 434 388 344 299 229 182 114 33
735 1.4 146 $258SONES 2.0 2.4 2.3 2.8 3.3 3.8 4.5 4.8 5.4 5.6
T500 HCFM 538 520 514 491 463 434 389 339 282 186
810 2.2 232 $300SONES 3.0 3.1 3.3 3.6 4.0 4.4 5.0 5.7 6.2 6.7
T700 HCFM 722 704 701 667 640 607 571 534 453 333
960 2.9 313 $315SONES 4.5 4.6 4.7 4.8 5.0 5.2 5.6 6.2 7.1 7.2
www.FaulknerHaynes.com 31
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
TWIN CITY FANSMODEL T900, T1500CEILING EXHAUST FAN, DIRECT DRIVE
• 120Volt Single Phase
• 12”W x 8”H Duct Connector
• Painted White Steel Grille
• Impact Resistant Centrifugal Blower Wheel
• Quiet Automatic Backdraft Damper
• Can be ducted horizontally or vertically. In-line ducting available with separate adapter.
• Use Electronic Variable Speed Controller to adjust blower speed and sound level (available separately).
Product Details
*Nominal voltage is 120VAC
*“H” and “V” refer to Horizontal and Vertical mounting
*Amps stated below rated at 60Hz
Notes:
See page 32 for fan accessories (speed controllers, inline adapters, radiation damper kits).
See page 30 for roof and wall caps accessories.
See page 28 for Vibration Isolators ($13/set).
Ps - Inches of Wg
Model 0.000 0.100 0.125 0.250 0.375 0.500 0.625 0.750 0.875 1.000 RPM AMPS WATTS Price
T900 HCFM 918 905 901 877 842 793 725 636 536 390
650 3.0 306 $380SONES 3.8 4.0 4.1 4.0 4.2 4.3 4.4 4.9 4.5 5.3
T1500 HCFM 1578 1526 1513 1438 1371 1285 1198 1103 1000 816
955 5.0 468 $463SONES 8.6 8.4 8.4 8.1 7.5 7.0 6.7 6.2 5.8 5.8
See page 36 for fan accessories (speed controllers, inline adapters, radiation damper kits).
See page 34 for roof and wall caps accessories.
See page 32 for Vibration Isolators ($13/set).
www.FaulknerHaynes.com32
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
TWIN CITY FANSVIBRATION ISOLATION KITS
FOR CEILING EXHAUST FANS
www.FaulknerHaynes.com 33
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• All heavy-gauge aluminum
• Low silhouette spun aluminum hood
• Weather resistant design for long life and maintenance free operation
• Galvanized bird screen is standard
• Stock available in 3 sizes for a wide range of performance capabilities
• One piece welded curb cap with round spun inlet for maximum efficiency
• Shipped completely assembled for ease in installation
• Intake or exhaust
Product Details
See page 35 for curbs.
GRV
SizeNeckArea(ft2)
Dimensions (inches)Estimated
Weight CFM/SP Curb SizeRequired
GRVPrice
CurbPrice
A B C D E F
090B 0.44 22.50 1.50
2
16.50 9 17 0-500/.025” 15” x 15” $153 $75
120B 0.8027.50
11.25 224
12.13 20 500-1000/.035” 22½” x 22½” $192 $82
160B 1.44 12.25 3 16.25 25 1000-1500/.047” 22½” x 22½” $222 $82
GRVCurb Mount Spun Aluminum Gravity Ventilator
www.FaulknerHaynes.com34
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
ROOF / WALL CAPS
$39634P
Model Price
• Built-in backdraft damper and bird screen
• For 3¼” x 10” or up to 6” round duct (Model 634M) or 8” round duct (Model 634)
• Steel housing, black electrically bonded epoxy finish
Roof Cap-Black Epoxy Finish
• Model 346S 6” round inlet
• Includes spring loaded damper and bird screen
• Model 348S 8” round inlet
Aluminum Wall Cap with Bird Screen
• Built-in bird screen
• 0.025 Aluminum - natural finish
• Model 611 up to 8” round inlet
• Model 611CM up to 8” round inlet curb mount
• Model 512 up to 12” round inlet
Aluminum Roof Caps
Model 611 shown here
See page 35 for curbs.
Size Curb SizeRequired
CapPrice
CurbPrice
611 N/A $55 N/A
612 N/A $98 N/A
611CM 14” x14” $65 $72
612CM 16” x 16” $105 $79
• Model 3412S 12” round inlet
• Model 3410S 10” round inlet
Model Price
346S $23
348S $25
3410S $51
3412S $57
www.FaulknerHaynes.com 35
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
ROOF CURBS & EQUIPMENT RAILS
• Constructed of 18 gauge galvanized steel
• Roof Curbs are 18” high
• Thickness is 1½” filled with 3# density rigid insulation
• Corners are mitered and welded for strength
• Factory installed 2” x 2” wood nailer
Roof Curbs
• Equipment supports are 18” high, 18 gauge galvanized steel curb, base plate and cap with 2” X 4” factory installed wood nailer
Equipment Rails
18” STD.
Section
18 ga. Galv. Metal
2 X 4 Wood Nailer
2” STD.1½” - 1’ - 0”
O.D. Size Price
12” x 12” $65
14” x 14” $72
15” x 15” $75
15½” x 15½” $76
16” x 16” $79
18½” x 18½” $86
22½” x 22½” $99
28' x 28” $124
32½” x 32½” $137
Length Price
3’ $90
4’ $99
5’ $115
6’ $142
www.FaulknerHaynes.com36
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
www.FaulknerHaynes.com
FAN ACCESSORIES
RADIATION DAMPERS FOR 100-700 FANS& METAL GRILLE FOR 100-300 FANS
$78
$96
$28
RD-1
RD-2
MG-1
100-300 Damper
400-700 Damper
Metal Grille 100-300
Model Fan Size Price
• Combination Fire/Radiation Damper
• UL Rated for 3Hr protection
• Metal grille has a white finish
• Creates cabinet exhaust fan into a inline fan
• Easy installation with detailed instructions
Fan Radiation Dampers & Metal Grille
Fan Inline Adapter Kits
• The FSC can offer excellent energy conservation and sound benefits when 100 percent operation is not required
• The FSC employs solid state circuitry for long life and dependability
• It is available on single phase motors only
• It is normally shipped loose for field installation
• Optional pre-wiring is available
Fan Speed Controller
$27
$27
3A (80L)
3A (57W)
Amp Price
$536A (72W)
FAN INLINE ADAPTER KITS
Model Size Price
961 L 100-150 Fans $17
981 L 200-300 Fans $17
982 L 400-700 Fans $27
983 L 900-1500 Fans $30
www.FaulknerHaynes.com38
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
CADCam-Latched Access Door / Duct Access Door
• For sizes below 12” x 12”, 24 gauge galvanized steel is used
• Insulation is 1 thick fiberglass
• Frame is constructed of 22 gauge galvanized steel
• Model CAD duct access doors employ an insulated door panel to provide a convenient and economical means to obtain access to components in ductwork utilized in low to medium pressure and velocity applications
• The gasket is compressible closed cell neoprene—door to frame and frame to duct
• Latches are plated steel, cam type
Product Details
POTTORFF
Model Size Price
CAD06X06 06X06 22.00
CAD08X08 08X08 22.00
CAD10X10 10X10 22.00
CAD12X12 12X12 22.00
CAD14X14 14X14 37.00
CAD16X16 16X16 37.00
CAD18X18 18X18 38.00
www.FaulknerHaynes.com 39
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
CFD-153-Hour Ceiling Radiation Damper
Size Price Size Price
$24 $40
6 x 6 12 x 12
8 x 8 14 x 14
9 x 9 20 x 20
22 x 2210 x 10
$21 $34
$29 $53
$56$29
CFD-15-NS
Size Price Size Price
$27 $45
6
8
10
16
14
12
$25 $40
$28
$37
CFD-15R-NS
• The CFD-15 ceiling radiation damper employs butterfly style blades for point-of-origin control of radiant heat in HVAC systems
• The CFD-15 is installed horizontally in the ceiling membrane of floor-ceiling or roof-ceiling assemblies with fire resistance ratings up to and including 3 hours
• Frame: 22 gauge galvanized steel. (24 gauge CFD-15R)
• Blades: 22 gauge galvanized steel – butterfly
• Insulated with ceramic refractory material for dampers larger than 114 in2
• Fire Closure Device: Fusible link
• Fire Closure Temperature: 165°F
Product Details
CFD-15-NS CFD-15R-NS
Thermal Blankets Only
$1924” x 24”
POTTORFF
www.FaulknerHaynes.com40
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
VFD-ISB / VFD-ISARFire Dampers
• Type B Fire Dampers • UL listed for Static and Dynamic requirements • Good for Horizontal and Vertical applications • Integral 14” sleeve • Includes perimeter retaining angles
Product Details
Type B
POTTORFF
VFD-ISB16
SizePrice
SizePrice
SizePrice
SizePrice
W H W H W H W H
6 6 $57
14
8 $59
18
10 $69 20
18 $89
86 $57 10 $63 12 $69 20 $89
8 $57 12 $63 14 $73
24
12 $78
10
6 $57 14 $66 16 $74 14 $89
8 $57
16
6 $61 18 $89 16 $89
10 $61 8 $61
20
6 $65 18 $99
12
6 $57 10 $65 8 $65 20 $100
8 $57 12 $65 10 $69 24 $108
10 $61 14 $67 12 $69 - - -
12 $61 16 $74 14 $80 - - -
14 6 $59 18 8 $65 16 $80 - - -
VFD-ISAR
Size Price Size Price
6 $50 14 $67
8 $50 16 $80
10 $55 18 $97
12 $55 20 $97
14” (305)Std.
www.FaulknerHaynes.com 41
POTTORFF
*See above for stocked sizes NON STOCK ITEM: Standard ShipQuick ship available. Additional charges may apply.
EFD-245 / EFD-437Extruded Aluminum Louver
• The EFD-437 drainable blade louver is designed to prevent water penetration in non-wind-driven rain applications by collecting water in frame and blade gutters and channeling it into downspouts and away from airflow paths
• The EFD-437 is available in a wide array of anodized and painted finishes including custom color matching
• Material: Mill finish 6063-T5 extruded aluminum
• Frame: 4” deep x 0.081” thick channel
• Blades: 37.5° x 0.081” thick drainable style
• Mullion: Visible
• Screen: 1/2” x 0.063” expanded and flattened aluminum
Product Details
Model # Stock W x H Square Foot F.A. Intake CFM (Max) Price
EFD-2458 x 8 0.1 100 $71
12 x 12 0.3 300 $71
EFD-437
18 x 18 0.9 900 $107
24 x 12 0.9 900 $85
24 x 24 1.9 1900 $130
36 x 36 4.9 4900 $245
48 x 48 9.2 9200 $360
www.FaulknerHaynes.com 43
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
MITSUBISHI ELECTRIC
• Ductless wall-mounted mini-split systems designed for comfort cooling and heating
• M-Series systems are not designed for equipment cooling applications in low ambient temperatures (e.g. data rooms)
• Indoor units are powered by outdoor units • Power supply: 208/230V, 1-phase, 60 Hz • See mini-split accessories page for linesets, pumps, wiring, etc. • For full product specifications, see www.mylinkdrive.com
Product Details
M-SERIESWALL-MOUNTED MINI-SPLITS
COMPATIBLE CONTROLLERS
Controller Model Description Price
Included with indoor unit Wireless HandheldIncluded with
indoor unit
MHK1Wireless, Wall-
Mounted, Backlit$240
PAR-33MAA +MAC-333IF-E
Wired, Wall-Mounted, Backlit, plus Adaptor
$492
PAC-US444CN-1 Thermostat Interface $152
PAC-UKPRC001-CN-1BACnet and
Modbus Interface$332
PAC-USWHS002-WF-1kumo cloud
Wi-Fi Interface$148
See Mini-Split controls page for detailed controls information.
MUZ Outdoor Unit. Size may vary with capacity.
MSZ Wall-Mounted Unit. Size may vary with capacity.
HEAT PUMP SYSTEMS
Indoor Unit Model
Outdoor Unit Model
Rated Cooling Capacity (Btu/h)
Rated Heating Capacity at 47°F (Btu/h)
SEER HSPFLine Size (Liquid -
Gas)
Max Total Piping Length
Max Height Difference
Breaker Size
(Amps)Price
MSZ-GL09NA-U1 MUZ-GL09NA-U1 9,000 10,900 24.6 12.81/4” - 3/8”
65 4015
$1,201
MSZ-GL12NA-U1 MUZ-GL12NA-U1 12,000 14,400 23.1 12.5 $1,347
MSZ-GL15NA-U1 MUZ-GL15NA-U1 14,000 18,000 21.6 11.71/4" - 1/2"
$1,650
MSZ-GL18NA-U1 MUZ-GL18NA-U1 18,000 21,600 20.5 11.2
100 50
$1,918
MSZ-GL24NA-U1 MUZ-GL24NA-U1 22,400 27,600 20.5 10.0
3/8" - 5/8"
20 $2,159
MSZ-D30NA-8 MUZ-D30NA-1 30,700 32,600 14.5 8.225
$2,502
MSZ-D36NA-8 MUZ-D36NA-1 33,200 35,200 14.5 8.2 $3,228
www.FaulknerHaynes.com44
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Ductless ceiling cassette mini-split systems designed for comfort cooling and heating
• M-Series systems are not designed for equipment cooling applications in low ambient temperatures (e.g. data rooms)
• Indoor unit provides four-way flow and is designed to fit into a 2’x2’ ceiling grid
• Includes built-in condensate pump for lift up to 19-11/16” • Includes knockout for outside air • Indoor units are powered by outdoor units • Power supply: 208/230V, 1-phase, 60 Hz • See mini-split accessories page for linesets, pumps, wiring, etc. • For full product specifications, see www.mylinkdrive.com
Product Details
M-SERIESCEILING CASSETTE MINI-SPLITS
SUZ Outdoor Unit
SLZ Ceiling Cassette Unit
MITSUBISHI ELECTRIC
HEAT PUMP SYSTEMS
Indoor Unit Model Outdoor Unit Model
Rated Cooling Capacity (Btu/h)
Rated Heating Capacity at
47°F (Btu/h)SEER HSPF
Line Size (Liquid -
Gas)
Max Total Piping Length
Max Height
Difference
Breaker Size
(Amps)Price
SLZ-KA09NAR1.TH* SUZ-KA09NA.TH 8,400 10,900 15.0 9.61/4" - 3/8"
65 40 15
$1,524
SLZ-KA12NAR1.TH* SUZ-KA12NA.TH 11,100 13,600 15.4 9.6 $1,733
SLZ-KA15NAR1.TH* SUZ-KA15NA.TH 15,000 18,000 16.0 9.6 1/4" - 1/2" $2,066
* Includes grille, SLP-15AAUW
COMPATIBLE CONTROLLERS
Controller Model Description Price
MHK1 Wireless, Wall-Mounted, Backlit $240
PAR-33MAA Wired, Wall-Mounted, Backlit $244
PAC-US444CN-1 Thermostat Interface $152
PAC-UKPRC001-CN-1 BACnet and Modbus Interface $332
PAC-USWHS002-WF-1 kumo cloud Wi-Fi Interface $148
See Mini-Split controls page for detailed controls information.
www.FaulknerHaynes.com 45
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Ductless ceiling cassette mini-split systems designed for comfort cooling and heating
• M-Series systems are not designed for equipment cooling applications in low ambient temperatures (e.g. data rooms)
• Indoor unit provides external static pressure up to 0.20 in Wg • Includes built-in condensate pump for lift up to 21-11/16” • Ultra-thin body is only 7-7/8” tall • Indoor units are powered by outdoor units • Power supply: 208/230V, 1-phase, 60 Hz • See mini-split accessories page for linesets, pumps, wiring, etc. • For full product specifications, see www.mylinkdrive.com
Product Details
M-SERIESHORIZONTAL DUCTED MINI SPLITS
MUZ Outdoor Unit. Size may vary with capacity.
SEZ Ducted Unit. Size may vary with capacity.
MITSUBISHI ELECTRIC
HEAT PUMP SYSTEMS
Indoor Unit Model Outdoor Unit Model
Rated Cooling Capacity (Btu/h)
Rated Heating Capacity at 47°F
(Btu/h)SEER HSPF
Line Size (Liquid -
Gas)
Max Total Piping Length
(ft)
Max Height
Difference (ft)
Breaker Size
(Amps)Price
SEZ-KD09NAR1.TH SUZ-KA09NA.TH 8,100 10,900 15.0 10.01/4" - 3/8"
65 4015
$1,508
SEZ-KD12NAR1.TH SUZ-KA12NA.TH 11,500 13,600 16.0 10.0 $1,676
SEZ-KD15NAR1.TH SUZ-KA15NA.TH 14,100 18,000 15.5 10.0 1/4" - 1/2" 20 $1,973
COMPATIBLE CONTROLLERS
Controller Model Description Price
MHK1 Wireless, Wall-Mounted, Backlit $240
PAR-33MAA Wired, Wall-Mounted, Backlit $244
PAC-US444CN-1 Thermostat Interface $152
PAC-UKPRC001-CN-1 BACnet and Modbus Interface $332
PAC-USWHS002-WF-1 kumo cloud Wi-Fi Interface $148
See Mini-Split controls page for detailed controls information.
www.FaulknerHaynes.com46
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Ductless wall-mounted mini-split systems designed for commercial cooling and heating
• P-Series systems can be used for equipment cooling down to 0°F ambient temperature with the addition of a wind baffle (to -20°F on some models)
• Indoor units are powered by outdoor units • Power supply: 208/230V, 1-phase, 60 Hz • See mini-split accessories page for linesets, pumps, wiring, etc. • For full product specifications, see www.mylinkdrive.com
Product Details
P-SERIESWALL-MOUNTED MINI-SPLITS
PUZ/PUY Outdoor Unit. Size may vary with capacity.
PKA Wall-Mounted Unit. Size may vary with capacity.Wind baffle for outdoor unit
COMPATIBLE CONTROLLERS
Controller Model Description Price
MHK1 Wireless, Wall-Mounted, Backlit $240
PAR-33MAA Wired, Wall-Mounted, Backlit $244
PAC-US444CN-1 Thermostat Interface $152
PAC-UKPRC001-CN-1 BACnet and Modbus Interface $332
PAC-USWHS002-WF-1 kumo cloud Wi-Fi Interface $148
See Mini-Split controls page for detailed controls information.
WIND BAFFLES
Wind Baffle Model Compatible Outdoor units Price
WB-PA4 12,000 & 18,000 Btu/h $108
WB-PA5 24,000 & 30,000 Btu/h $124
WB-PA3, Qty. 2 36,000 Btu/h $320
BRANCH JOINT
Model Compatible Outdoor units Price
MSDD-50TR-E 12,000, 18,000 & 24,000 Btu/h $88
Indoor Unit Model
Outdoor Unit Model
Rated Cooling Capacity (Btu/h)
Rated Heating Capacity at 47°F (Btu/h)
SEER HSPFLine Size (Liquid -
Gas)
Max Total Piping
Length (ft)
Max Height
Difference (ft)
Breaker Size
(Amps)Price
HE
AT P
UM
P
SYS
TEM
S
PKA-A12HA7 PUZ-A12NKA7 12,000 14,000 20.8 10.21/4" - 1/2" 100
100
15$2,114
PKA-A18HA7 PUZ-A18NKA7 18,000 19,000 18.5 10.2 $2,529
PKA-A24KA7.TH PUZ-A24NHA7 24,000 26,000 21.4 11.0
3/8" - 5/8" 16525
$2,989
PKA-A30KA7.TH PUZ-A30NHA7 30,000 32,000 19.8 9.9 $3,511
PKA-A36KA7.TH PUZ-A36NKA7 36,000 38,000 18.8 9.2 30 $3,887
CO
OLI
NG
ON
LY
SYS
TEM
S
PKA-A12HA7 PUY-A12NKA7 12,000
N/A
20.8
N/A
1/4" - 1/2" 100
100
15$2,043
PKA-A18HA7 PUY-A18NKA7 18,000 18.5 $2,439
PKA-A24KA7.TH PUY-24NHA7 24,000 21.4
3/8" - 5/8" 16525
$2,890
PKA-A30KA7.TH PUY-A30NHA7 30,000 19.8 $3,395
PKA-A36KA7.TH PUY-A36NKA7 36,000 18.8 30 $3,766
MITSUBISHI ELECTRIC
www.FaulknerHaynes.com 47
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Ductless ceiling cassette mini-split systems designed for commercial cooling and heating
• P-Series systems can be used for equipment cooling down to 0°F ambient temperature with the addition of a wind baffle (to -20°F on some models)
• Indoor unit provides four-way flow with approximate dimensions of 33”x33”
• Includes 3D i-see sensor for occupancy detection and airflow control (requires PAR-33MAA controller)
• Includes built-in condensate pump for lift up to 33-7/16” • Includes knockouts for outside air and branch duct • Indoor units are powered by outdoor units • Power supply: 208/230V, 1-phase, 60 Hz • See mini-split accessories page for linesets, pumps, wiring, etc. • For full product specifications, see www.mylinkdrive.com
Product Details
P-SERIESCEILING CASSETTE MINI-SPLITS
PUZ/PUY Outdoor Unit. Size may vary with capacity.
PLA Ceiling Cassette Unit
Wind baffle for outdoor unit
Indoor Unit Model
Outdoor Unit Model
Rated Cooling Capacity (Btu/h)
Rated Heating
Capacity at 47°F (Btu/h)
SEER HSPFLine Size (Liquid -
Gas)
Max Total Piping Length
(ft)
Max Height
Difference (ft)
Breaker Size
(Amps)Price
HE
AT P
UM
P
SYS
TEM
S
PLA-A12EA7* PUZ-A12NKA7 12,000 14,000 27.0 12.81/4" - 1/2" 165 100 15
$2,882
PLA-A18EA7* PUZ-A18NKA7 18,000 19,000 24.6 11.0 $3,284
PLA-A24EA7* PUZ-A24NHA7 24,000 26,000 24.2 11.2
3/8" - 5/8" 225 100
25 $3,840
PLA-A30EA7* PUZ-A30NHA7 30,000 32,000 22.8 11.630
$4,504
PLA-A36EA7* PUZ-A36NKA7 36,000 38,000 21.8 10.4 $4,953
CO
OLI
NG
ON
LY
SYS
TEM
S
PLA-A12EA7* PUY-A12NKA7 12,000
N/A
27.0
N/A
1/4" - 1/2"165 100 15
$2,811
PLA-A18EA7* PUY-A18NKA7 18,000 24.6 1/4" - 1/2" $3,194
PLA-A24EA7* PUY-24NHA7 24,000 24.2 3/8" - 5/8"
225 100
25 $3,741
PLA-A30EA7* PUY-A30NHA7 30,000 22.8 3/8" - 5/8"30
$4,388
PLA-A36EA7* PUY-A36NKA7 36,000 21.8 3/8" - 5/8" $4,832
*Includes PLP-40EAEU Grille.
COMPATIBLE CONTROLLERS
Controller Model Description Price
MHK1Wireless, Wall-
Mounted, Backlit$240
PAR-33MAAWired, Wall-
Mounted, Backlit$244
PAC-US444CN-1Thermostat Interface
$152
PAC-UKPRC001-CN-1BACnet and Modbus
Interface$332
PAC-USWHS002-WF-1kumo cloud Wi-Fi
Interface$148
See Mini-Split controls page for detailed controls information.
WIND BAFFLES
Wind Baffle Model
Compatible Outdoor units Price
WB-PA412,000 &
18,000 Btu/h$108
WB-PA524,000 &
30,000 Btu/h$124
WB-PA3, Qty. 2 36,000 Btu/h $320
BRANCH JOINT
Model Compatible Outdoor units Price
MSDD-50TR-E 12,000, 18,000 & 24,000 Btu/h $88
MITSUBISHI ELECTRIC
www.FaulknerHaynes.com48
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Horizontal ducted mini-split systems designed for commercial cooling and heating
• P-Series systems can be used for equipment cooling down to 0°F ambient temperature with the addition of a wind baffle (to -20°F on some models)
• Indoor unit provides external static pressure up to 0.60 in Wg • Includes built-in condensate pump for lift up to 27-9/16” • Thin body is only 9-7/8” tall • Indoor units are powered by outdoor units • Power supply: 208/230V, 1-phase, 60 Hz • See mini-split accessories page for linesets, pumps, wiring, etc. • For full product specifications, see www.mylinkdrive.com
Product Details
PUZ/PUY Outdoor Unit. Size may vary with capacity.
PEAD Ducted Unit. Size may vary with capacity.
Wind baffle for outdoor unit
Indoor Unit Model
Outdoor Unit Model
Rated Cooling Capacity (Btu/h)
Rated Heating
Capacity at 47°F (Btu/h)
SEER HSPFLine Size (Liquid -
Gas)
Max Total Piping Length
(ft)
Max Height
Difference (ft)
Breaker Size
(Amps)Price
HE
AT P
UM
P
SYS
TEM
S
PEAD-A18AA7 PUZ-A18NKA7 18,000 19,000 19.9 10.2 1/4" - 1/2" 100
100
15 3120
PEAD-A24AA7 PUZ-A24NHA7 24,000 26,000 19.6 10.8
3/8" - 5/8" 16525
3560
PEAD-A30AA7 PUZ-A30NHA7 30,000 32,000 19.1 10.8 4072
PEAD-A36AA7 PUZ-A36NKA7 36,000 38,000 19.1 9.9 30 4425
CO
OLI
NG
O
NLY
S
YSTE
MS
PEAD-A18AA7 PUY-A18NKA7 18,000
N/A
19.9
N/A
1/4" - 1/2" 165
100
15 3030
PEAD-A24AA7 PUY-24NHA7 24,000 19.6
3/8" - 5/8" 22525
3461
PEAD-A30AA7 PUY-A30NHA7 30,000 19.1 3956
PEAD-A36AA7 PUY-A36NKA7 36,000 19.1 30 4304
COMPATIBLE CONTROLLERS
Controller Model Description Price
MHK1Wireless, Wall-
Mounted, Backlit$240
PAR-33MAAWired, Wall-
Mounted, Backlit$244
PAC-US444CN-1Thermostat Interface
$152
PAC-UKPRC001-CN-1BACnet and Modbus
Interface$332
PAC-USWHS002-WF-1kumo cloud Wi-Fi
Interface$148
See Mini-Split controls page for detailed controls information.
WIND BAFFLES
Wind Baffle Model
Compatible Outdoor units Price
WB-PA412,000 &
18,000 Btu/h$108
WB-PA524,000 &
30,000 Btu/h$124
WB-PA3, Qty. 2 36,000 Btu/h $320
P-SERIESHORIZONTAL DUCTED MINI-SPLITS
BRANCH JOINT
Model Compatible Outdoor units Price
MSDD-50TR-E 12,000, 18,000 & 24,000 Btu/h $88
MITSUBISHI ELECTRIC
www.FaulknerHaynes.com 49
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Multi-zone mini-split systems designed for comfort cooling and heating
• Multi-zone systems are not designed for equipment cooling applications in low ambient temperatures (e.g. data rooms)
• Minimum of two indoor units must be connected • Minimum installed capacity is 12,000 Btu/h • Total connected capacity must not exceed 130% of outdoor unit
capacity • Indoor units are powered by outdoor units • Power supply: 208/230V, 1-phase, 60 Hz • See mini-split accessories page for linesets, pumps, wiring, etc. • For full product specifications, see www.mylinkdrive.com
Product Details
MULTI-ZONE MINI-SPLITS
PUZ/PUY Outdoor Unit. Size may vary with capacity.
MITSUBISHI ELECTRIC
HEAT PUMP OUTDOOR UNITS
Outdoor Unit Model
Max Number of Indoor
Units
Rated Cooling Capacity (Btu/h)
Rated Heating
Capacity at 47°F (Btu/h)
SEER (Ducted/
Non-ducted)
HSPF (Ducted /
Non-ducted)
Max Total
Piping Length
(ft)
Max Piping Length
Per Indoor
Unit (ft)
Max Height
Difference (ft)
Breaker Size
(Amps)Price
MXZ-2C20NA2 2 18,000 22,000 20.0 / 16.0 10.0 / 9.3 164
82
33 20 $1,387
MXZ-3C24NA2-U1 3 22,000 25,000 20.0 / 16.0 9.8 / 9.2
23049
25
$1,907
MXZ-3C30NA2-U1 3 28,400 28,600 19.0 / 16.2 10.6 / 9.6 $2,144
MXZ-4C36NA2-U1 4 35,400 36,000 19.2 / 16.0 11.0 / 9.8 $2,394
MXZ-5C42NA-U1 5 40,500 45,000 19.7 / 15.2 9.2 / 9.0 262 40 $2,908
COMPATIBLE CONTROLLERS
Model Description Price
MHK1 Wireless, Wall-Mounted, Backlit $240
PAR-33MAA Wired, Wall-Mounted, Backlit $244
MAC-333IF-EAdaptor to connect PAR-33MAA
to MSZ or MFZ indoor unit$248
PAC-US444CN-1 Thermostat Interface $152
PAC-UKPRC001-CN-1 BACnet and Modbus Interface $332
PAC-USWHS002-WF-1 kumo cloud Wi-Fi Interface $148
See Mini Split Controls page for detailed controls information.
PORT ADAPTORS
ModelDescription
(Outdoor unit to line size)
Price
MAC-A454JP-E 3/8" to 1/2" $43
MAC-A455JP-E 1/2" to 3/8" $43
MAC-A456JP-E 1/2" to 5/8" $43
PAC-493PI 1/4" to 3/8" $43
PAC-SG76RJ-E 3/8" to 5/8" $43
www.FaulknerHaynes.com50
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
MULTI-ZONE MINI-SPLITSMITSUBISHI ELECTRIC
Indoor Unit Model Rated Cooling Capacity (Btu/h)
Rated Heating Capacity at 47°F (Btu/h) Line Size (Liquid - Gas) Price
WA
LL-M
OU
NTE
D I
ND
OO
R U
NIT
S
MSZ-GL06NA-U1 6,000 7,200
1/4" - 3/8"
$393
MSZ-GL09NA-U1 9,000 10,900 $432
MSZ-GL12NA-U1 12,000 14,400 $512
MSZ-GL15NA-U1 14,000 18,000
1/4" - 1/2"
$620
MSZ-GL18NA-U1 18,000 21,600 $647
MSZ-GL24NA-U1 22,400 27,600 3/8" - 5/8" $723
CE
ILIN
G C
AS
SE
TTE
IN
DO
OR
UN
ITS
(2
2"
X 2
2")
SLZ-KA09NAR1.TH *1 8,400 10,900
1/4" - 3/8"
$722
SLZ-KA12NAR1.TH *1 11,100 13,600 $819
SLZ-KA15NAR1.TH *1 15,000 18,000 1/4" - 1/2" $974
CE
ILIN
G C
AS
SE
TTE
IN
DO
OR
UN
ITS
(3
3"
X 3
3")
PLA-A12EA7 *2 12,000 14,000
1/4" - 1/2"
$1,729
PLA-A18EA7 *2 18,000 19,000 $2,003
PLA-A24EA7 *2 24,000 26,000 3/8" - 5/8" $2,253
HO
RIZ
ON
TAL
DU
CTE
D
IND
OO
R U
NIT
S (
ES
P =
0
.20
IN
WG
)
SEZ-KD09NAR1.TH 8,100 10,900
1/4" - 3/8"
$706
SEZ-KD12NAR1.TH 11,500 13,600 $762
SEZ-KD15NAR1.TH 14,100 18,000 1/4" - 1/2" $881
HO
RIZ
ON
TAL
DU
CTE
D
IND
OO
R U
NIT
S
(ES
P =
0.6
0
INW
G) PEAD-A18AA7 18,000 19,000 1/4" - 1/2" $1,390
PEAD-A24AA7 24,000 26,000 3/8" - 5/8" $1,571
*1, Includes grille, SLP-15AAUW*2, Includes grille, PLP-40EAEU
www.FaulknerHaynes.com 51
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
MINI-SPLITS CONTROLS
CONTROLS
Model Description Details Price
MHK1Wireless, Wall-Mounted, Backlit. Includes controller and receiver.
Includes remote controller and receiver. $240
PAR-33MAA Wired, Wall-Mounted, BacklitRequires MAC-333IF-E for MSZ or MFZ indoor units.
Use 16/2 to 22/2 shielded or unshielded wire.$244
PAC-US444CN-1 Thermostat InterfaceAllows nearly any third-party thermostat to control
indoor units.$152
VPL24-210 Transformer for Thermostat Interface 230/115V to 24V, 5 VA. $16
PAC-UKPRC001-CN-1 BACnet and Modbus Interface One interface required per indoor unit. $332
USB-RS485 USB to RS485 Adaptor Used to configure BACnet and Modbus Interface. $12
PAC-USWHS002-WF-1 kumo cloud Wi-Fi InterfaceAllows remote control from kumo cloud app or
kumocloud.com.$148
MAC-333IF-E M-Net adaptor for M-series systems.Allows the M-Series indoor units to communicate with the CITY MULTI Controls Network via M-Net. Also used to connect PAR-33MAA to MSZ and MFZ indoor units
$248
PAC-SF83MA-EM-Net adaptor for P-series outdoor units from 24,000 to 42,000 Btu/h
Allows the P-Series outdoor units to communicate with the CITY MULTI Controls Network via M-Net.
$228
PAC-SJ19MA-EM-Net adaptor for P-series outdoor units from 12,000 to 18,000 Btu/h
Allows the P-Series outdoor units to communicate with the CITY MULTI Controls Network via M-Net.
$228
Note: No controllers are combatible with the MSZ-HM indoor units (not stocked by Faulkner Haynes)For existing units and older models, verify compatibility on www.mylinkdrive.com
Wireless Remote - MHK1
USB to RS485 Adaptor
Wired Remote - PAR-33MAA
kumo cloud Wi-Fi Interface - PAC-USWHS002-WF-1
Thermostat Adaptor - PAC-US444CN-1
M-Net Adaptor - MAC-333IF-E
MITSUBISHI ELECTRIC
www.FaulknerHaynes.com52
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• Wiring to connect the indoor and outdoor units for all M&P-series mini-splits by Mitsubishi Electric
• Provides both power and control cable between indoor and outdoor units
• UV resistant and suitable for direct burial
Product Details
• Two insulated linesets are machined together for faster and easier installation
• White polyethylene jacket protects foam insulation from tearing during installation process
• Jacket includes sequential foot markings to ensure accurate refrigerant charge
• Insulation is UV resistant and can be painted to match the surroundings
Product Details
MINI-SPLIT AND VRF ACCESSORIES
MINI-SPLIT WIRING
Model Line Size (Liquid - Gas)
Insulation Thickness (inches) Length (ft) Price
TG.LSIN143812030 1/4” - 3/8” 1/2” 30’ $83
TG.LSIN143812050 1/4” - 3/8” 1/2" 50' $138
TG.LSIN141212050 1/4” - 2/3” 1/2" 50' $160
TG.LSIN385812050 3/8” - 5/8” 1/2" 50' $208
TG.LSIN383412050 3/8” - 3/4” 1/2" 50' $240
Model Part Number Description Use Color Packaging Type Length (ft) Price
1070
1070390814/4, Stranded, THHN, 600V,
Tray Cable
Must be installed indoors in cable tray or conduit
Black Coil 50' $40
10700108 Black Reel 250' $190
1075
10753908 14/4, Stranded, THHN,
Jacketed Metal Clad
Can be installed indoors without
conduit
Black Coil 50' $57
10750108 Black Reel 250' $284
PRE-INSULATED TWINNED LINESETS
MITSUBISHI ELECTRIC
www.FaulknerHaynes.com 53
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
MINI-SPLIT AND VRF ACCESSORIES
ELECTRICAL DISCONNECT SWITCHES
CONDENSATE PUMPS
• Disconnect switch between the indoor and outdoor units for all M&P-series mini-splits by Mitsubishi Electric
• Specialty 3-pole switch
• The MicroBlue and MaxiBlue pump use rotary diaphragm technology for wiper quiet sound levels and the ability to run wet or dry
• The MicroBlue and MaxiBlue pump include a 3-year warranty • The MicroBlue pump can be installed in any orientation • The DPLS2 indoor drain sensor is typically used as a secondary
float switch on indoor units where no pump is required
Product Details
Product Details
Model Description Use Color Price
MS303-DS 30 A, 600V, Toggle 3-Pole AC Switch Mini-split indoor unit disconnect Black $55
Model Description Use Voltage Max Flow (gallons/hr) Max Head (ft) Max Suction
Lift (ft) Price
X85-003 MicroBlue pump and
resorvoir18,000 Btu/h and below 110V - 230V 1.3 16' 6' $136
X87-721 MaxiBlue Pump 48,000 Btu/h and below 208V - 230V 3.7 23' 16.5' $181
T18-016Fascia kit for MicroBlue
pump installation underneath wall-mounted indoor unit
– – – – – $32
C13-10316' extension cable for
MaxiBlue pump– – – – – $34
DPLS2 Indoor Drain SensorFloat switch for units
where no pump is required
– – – – $60
MITSUBISHI ELECTRIC
www.FaulknerHaynes.com54
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• UltraLite pads are lightweight, durable and feature a concrete surface to be installed on level ground.
• QuickSling mounting stands use powder-coated steel tubing to keep outdoor units above the snow line.
• QuickSling mounting stands can be mounted on a concrete pad or a roof and the height-adjustable feet can be bolted down
• Both the QuickSling wall bracket and mounting stands include legs that can be adjusted to fit any Mitsubishi mini-split
• Hef-T-Block mounting blocks can be used as a simple support when condensing units must be bolted down.
Product Details
Model Description Dimensions Mounting Height Weight (lbs) Max Outdoor Unit Weight (lbs) Price
UC1636-3UltraLite Lightweight Concrete
Equipment Pad
Length: 16" Width: 36"
3"11 754 $23
UC2442-3Length: 24" Width: 42"
18 1309 $34
QSMS1201QuickSling Single-Fan
Mounting StandWidth: 34" - 40"
Depth: 25"12" – 400 $130
QSMS1202QuickSling Dual-Fan
Mounting StandWidth: 34" - 42"
Depth: 36"12" – 400 $140
QSWB2000 QuickSling Wall BracketWidth: 34"Depth: 25"
– 3.25 350 $87
230-MB17WHef-T-Block Mounting Blocks
(Pack of 2)Length: 17"Width: 3.5"
3.5" 3.25 900 $18
230-MBCWEnd Caps for Hef-T-Block
(Pack of 4)– – – – $8
MINI-SPLIT OUTDOOR UNIT PADS, MOUNTS, AND BRACKETS
MINI-SPLIT AND VRF ACCESSORIES
UltraLite Lightweight Concrete Equipment Pad
QuickSling Mounting Stand QuickSling Wall Bracket Hef-T-Block Mounting Blocks
MITSUBISHI ELECTRIC
www.FaulknerHaynes.com 55
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
MINI-SPLIT AND VRF ACCESSORIES
ISOLATION BALL VALVES
VRF CONTROL WIRING
• Control wiring for all CITY MULTI VRF systems between outdoor units, BC controllers, and indoor units.
• Jacket includes sequential foot markings
Product Details
• Full-port ball valves are used to isolate indoor units or piping sections on CITY MULTI VRF systems
• Includes Schrader service valve • Includes insulation
Product Details
Model Part Number Size Insulation Thickness (inches) Description Price
NBV02-S NBV02-S-IN 1/4"
3/4"Brazed connections,
Schrader valve, insulation
$25
NBV03-S NBV03-S-IN 3/8" $25
NBV04-S NBV04-S-IN 1/2" $25
NBV05-S NBV05-S-IN 5/8" $25
NBV06-S NBV06-S-IN 3/4" $44
Model Part Number Description Use Color Packaging Type Length (ft) Price
1320001320-250 16/2, Bare Copper,
Shielded, Control CablePlenum-rated White Reel
250' $64
001320-1000 1,000' $255
MITSUBISHI ELECTRIC
www.FaulknerHaynes.com56
MASON INDUSTRIES
CERTIFIED CALCULATIONS BY PROFESSIONAL ENGINEERS
Certified Seismic Restraints
Once again MASON is setting the pace, leading in the resilient mounting of equipment in Blast and Seismic Zones.
www.FaulknerHaynes.com 57
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
MASON INDUSTRIESVIBRATION ISOLATIONSpring Mounts, Hangers, Pads
MODEL 30N
Type
76 lbs. or 1½” Water Pipe
113 lbs. or 2” Water Pipe
130 lbs. or 2½” Water Pipe
210 lbs. or 4” Water Pipe
336 lbs. or 5” Water Pipe
X-76
X-113
X-130
X-210
X-336
Price Each
$28
$28
$34
$34
$47
Weight Capacity
MODEL SLF
Type
Up to 133 lbs.
Up to 130 lbs.
Up to 75 lbs.
Up to 200 lbs.
Up to 400 lbs.
Up to 625 lbs.
Up to 1000 lbs.
X-113
X-130
A-75
A-200
A-400
A-625
B-1000
Price Each
$28
$34
$45
$45
$60
$60
$70
Weight Capacity
MODEL SW (SUPER W)
Price EachSize
$243 X 3 X 3/4” Thick
Spring Mounts
Spring/Neoprene Hangers
Neoprene Hanger
Waffle Pads
*Call for larger sizes.
Note:
*Call for larger sizes.
*Based on 10’ Hanger Spacing
Notes:
3x3 provides (9) 2-inch modules
Note:
MODEL HDA
Type/Model
$17
$17
0-35 LBHDA Black
HDA Red 30-75 LB
Weight Rating Price
www.FaulknerHaynes.com58
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
www.FaulknerHaynes.com
SEISMIC RESTRAINTSAnchor Bolts, Cable Braces
SEISMIC ANCHOR BOLTS & STUDS
Call forPricing
SAS 3/8”
SAS 1/2”
SAS 5/8”
SAST 3/8”
SAST 1/2”
5/8”
Model Size Price
SEISMIC CABLE BRACES
Call forPricing
SCB-1 1/8”
SCB-2 3/16”
SCBH-0 1/16”
SCBH-1 1/8”
SCBH-2 3/16”
Model Cable Size Price
Model SCBH
Model SCB
SASTSeismic Anchor Self Tapping
SASSeismic Anchor Stud
*Setting Tool $5.00
Note:
*Call For Quantity Pricing on SCB
* Aircraft Cables available in the following sizes: 1/16”, 1/8”, 3/16” and 3/32”
Notes:
SCB-0 1/16”
SAST
MASON INDUSTRIES
www.FaulknerHaynes.com60
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
DANFOSS VLT HVAC DRIVES
HP
7.5 11
5 8.2VLT-FC-102-5HP-460-3Ø
VLT-FC-102-7.5HP-460-3Ø
VLT-FC-102-10HP-460-3Ø
VLT-FC-102-15HP-460-3Ø
VLT-FC-102-20HP-460-3Ø
VLT-FC-102-25HP-460-3Ø
VLT-FC-102-30HP-460-3Ø
VLT-FC-102-40HP-460-3Ø
VLT-FC-102-50HP-460-3Ø
$1030 $1469
$1090 $1520
$1213 $1645
$1473 $1936
$1755 $2309
$2190 $2746
$2506 $3086
$2939 $3548
$3738 $4506
10 14
15 21
20 27
25 34
30 40
40 52
50 65
Type AmpsBase Drivewith Disc
Vertical Bypass w/ 2 Contactor Bypass and Disconnect
• Wall Mount, NEMA 1, UL Type 1
• Horse power ratings from 5 to 50
• Dual DC Link Reactors
• Flexible Menu Structure
• System Protection
• Drive Protection
• Motor Protection
• Automatic Energy Optimization (AEO)
• Automatic Switching Frequency Modulation (ASFM)
• Control Board
• EMI/RFI filter, built-in
• Choke, built-in
• Communications
• Advanced Control Panel
– 5% DC-Link reactors integrated
– Intuitive navigation
– Four independent PID Loops
– HVAC Application Menu
– Personal Menu
– Quick Startup Menu
– Belt Monitoring
– No flow pumping, dead head protection
– Metal oxide varistors and capacitor snubber on the input
– Input short circuit
– Ground fault and phase loss
– UL I2T overload
– Output short circuit
– Ground fault and phase loss
– Adjusts motor voltage to optimize energy savings
– Quiet motor operation at critical flow conditions
– Pump end of curve protection
– Automated Vibration avoidance
– Reduction in harmonics
– No voltage drop or efficiency losses
– 2 Programmable Analog Inputs
– 1 Programmable Analog Output
– 6 Programmable Digital Inputs (2 Can be Digital Outputs)
– Up to 31 drive on one serial bus
– Real Time Clock
– Displays up to four meters simultaneously
– Plain language alarms and warnings
– Two level password protection
– Hot-Pluggable Keypad
– Johnson controls Metasys® N2, Modbus RTU, Siemens Apogee® FLN standard, BACnet MS/TP
– USB port enables programming and monitoring via PC
– 2 Relay Outputs
– Expandable with Optional Cards
DANFOSS VLT HVAC Drive FC 102 Product Features
Drive Only
$640
$855
$1402
$2137
$720
$1113
$1809
$2590
$3289
DANFOSS
www.FaulknerHaynes.com 61
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
HART COOLEY FLEXIBLE AIR DUCTMODEL F218
• Class I Air Duct • Metalized polyester jacket with reinforced fiberglass scrim • Two-ply black polyester core • Rated pressures (UL-181): 12 in W.C. positive, ½ in W.C. negative • Rated maximum air velocity: 5000 FPM • Silver Jacket • UL Listed
Product Details
FLEXIBLE DUCT
PRODUCT SPECIFICATIONS
Diameter 4-20 inches (6-20 inches in stock)
Pressure Rating Inches in Water Guage (WG)
Positive Pressure 12 inches
Negative Pressure ½ inch
Velocity 5000 FPM
R-Value R - 8.0
F218 HART COOLEY FLEXIBLE DUCT
Diameter Price Per 25’ Length
6 $32
8 $49
10 $61
12 $72
14 $88
16 $105
18 $125
20 $159
www.FaulknerHaynes.com 63
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
STERLING
• GG Series gas-fired unit heaters combine the latest tubular heat exchanger technologies with a unique single-orifice burner system for superior durability, reliability and performance. GG Series propeller units are available in sizes from 30 to 120 MBH and offer industry leading operating efficiencies in a compact low-profile design perfect for applications where space is limited.
• Standard features: direct spark ignition, power vented, LP conversion kit included, field convertible to separated combustion (must add 11AS-X7-4 or 11AX-X7-5), 10 year heat exchanger warranty
Product Details
GG SERIES
Model Description BTUs Efficiency BTU output Weight Price LP conv kit
GG060 power vented gas fired unit heater 60,000 82% 49,800 80 $670 std
GG075 power vented gas fired unit heater 75,000 82% 61,500 85 $695 std
GG105 power vented gas fired unit heater 105,000 82% 86,100 105 $800 std
GG120 power vented gas fired unit heater 120,000 82% 98,400 110 $875 std
UNIT HEATER ACCESSORIES
Model Description Price
11AS-VC-4 4" vent Cap GG75-120 $70
11AS-X7-4 4" concentric vent kit GG60-75 $220
11AS-X7-5 5" concentric vent kit GG90-120 $315
T1 Swivel Hanging Bracket $115
T87K 1 stage Heating only T-stat $45
www.FaulknerHaynes.com64
STOCK ITEM: Next Day Availability(Must be ordered by 2pm Eastern Time)
• TF Series gas-fired unit heaters combine the latest tubular heat exchanger technologies with an innovative “In-Shot” burner system for superior durability, reliability and performance in a commercial unit heater. Units are propeller (TF) configurations . Sizes range from 100 to 400 MBH with industry leading operating efficiencies and carry a 10-year heat exchanger warranty.
• Standard features: direct spark ignition, power vented, 10 year heat exchanger warranty. LP conversion kit, if can required, can be added.
Product Details
TF SERIES
Model Description BTUs Efficiency BTU output Weight Price LP conv kit
TF150 power vented gas fired unit heater 150,000 83% 124,500 155 $960 $45
TF175 power vented gas fired unit heater 175,000 83% 145,250 191 $1,050 $45
TF200 power vented gas fired unit heater 200,000 83% 166,000 201 $1,140 $45
TF250 power vented gas fired unit heater 250,000 83% 207,500 211 $1,280 $45
UNIT HEATER ACCESSORIES
Model Description Price
11AS-M2-2 5" vent cap TF150-250 $75
T1 Swivel Hanging Bracket $115
T87K 1 stage Heating only T-stat $45
STERLING
Faulkner / Haynes & Associates, Inc.Faulkner Haynes, Inc.
REPRESENTING THE FOLLOWING QUALITY PRODUCTS:
ACTIVE AIR SOLUTIONS• Bi-Polar Ionization
CAMBRIDGE ENGINEERING• Energy Efficient Direct-Fired Blow
through Space Heaters• Make-up Air Units
CAPTIVE AIRE• Dedicated Outside Air Units (DOAS) • Kitchen Hood Exhaust Systems
DANFOSS• Variable Frequency Drives
DESERT AIRE• Swimming Pool and Industrial
Dehumidifiers • Dedicated Outside Air Units (DOAS)
FRIEDRICH• Room Air Conditioning• PTACs• VTACs• VRP with Inverter Driven
Compressors
HONEYWELL ANALYTICS• Gas Monitoring Systems
HOWDEN BUFFALO• Industrial Fans and Blowers
INSUL-PIPE SYSTEMS• Pre-Insulated and Pre-Fabricated
Underground Piping Systems
LENNOX• Commercial A/C and Heating
Roof-Top Units and Split Systems
LIEBERT BY VERTIV• Computer Room A/C• UPS• Surge Suppressors• IT Infrastructure
MASON INDUSTRIES• Vibration Isolation• Floating Floors• Seismic Restraint
MITSUBISHI ELECTRIC• City Multi Variable Refrigerant
Flow (VRF)• Ductless Split Systems
MONOXIVENT• Vehicle Exhaust Systems• FRP Underground Duct• Source Capture Fume Arms
NEPTRONIC• Actuators• Actuated Valves• Humidifiers• Controls• Electric Heaters
PENNBARRY• Ceiling Exhaust Fans• Energy Recovery Units
POTTORFF• Fire/Smoke/Control Dampers• Louvers
PREMISYS• Dedicated Outdoor Air Systems
(DOAS) by Mitsubishi Electric
PRIHODA• Fabric Ductwork• Diffuser Systems
RAYWALL• Electric Heating Products by TPI
SKYBLADE• HVLS Destratification Fans
STERLING HEATERS• Gas Fired Unit Heaters
SYSTEMAIR• Special Application ERV
TEMPMASTER• Commercial Roof-Top• Split Systems• Heat Pumps
THERMADUCT• Pre-Engineered and Pre-Insulated
Outdoor Ducting Systems
THERMAFLEX• Flexible Duct Products
THERMOLEC• Electric Duct Heaters
TITUS• Displacement Ventilation• Chilled Beams• Grilles• Diffusers• Terminal Units• VAV Diffusers• Fan Coils• Air Handling Units
TURNKEY DUCT• Spiral Round• Flat Oval• Rectangular
TWIN CITY• Fans and Blowers
VIBRO-ACOUSTICS• Sound Attenuators
YOUNG REGULATORS• Dampers Regulators• Controls