Description: This system contains a STI-6400 with a DPDT key switch to be mounted on one side of a door or wall; and a similar looking housing, also with a DPDT key switch, but without an alarm for the opposite side of the door. An authorized person with a key can disable the alarm on either side of the door. When disabled, and LED will illuminate, and the door can be opened without setting off the alarm. After passing through the door, the alarm can be armed again from the opposite side. Installation: 1. Follow STI-6400 mounting instructions and set switches to the desired positions for alarm timing and volume. 2. For straight through door or wall installation, mark the center of the 5/16 inch hole in the mounted base, then remove the base from the door or wall. 3. Drill a 5/16 inch diameter hole through the door or wall at the marked location. 4. Align the same diameter hole in the secondary unit base to the back side of the door or wall and mount. 5. Route the wire from the STI-6400 unit through the hole and into the secondary unit. 6. Attach the 6 wires to the terminal block pins 2 thru 7 matching wire colors on the terminal block label. 7. Seal the hole around the wires with an effective fire stop material, if required. 8. Attach the battery in the secondary unit and install the cover. 9. Cycle the key switch to be sure the LED’s turn “ON” and “OFF”. Leave the LED’s “ON” until ready to test the alarm. 10. Attach the battery to the STI-6400 and install the cover. 11. Close the door and test. Operation: 1. With the door closed, turn either key switch to arm the alarm. The LED’s on both sides of the door should turn “OFF”. 2. If the door is opened while the LED’s are “OFF”, then the alarm will sound according to the switch settings of the STI-6400. 3. To reset the alarm, turn either key to the opposite position (the LED’s will turn “ON”), close the door and turn either key switch again (the LED’s will turn “OFF”). 4. When the system is armed, authorized passage can be accomplished by turning either key switch until the LED’s turn “ON”, and remove key. The door can now be opened without sounding the alarm. When passage is complete, close the door, turn the key switch (the LED’s will turn “OFF”). The door alarm is once again armed. Addendum for STI-6406 with Dual Access Control Schematic Diagram: 13 February 2017

STI-6400 with Dual Access Control · Electronics: STI-6403 and STI-6404 - Remote Horn Unit Power Source 9 VDC operating power* only Horn Volume at 1 ft. 95 dB low / 105 dB high Stand

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

  • Description: This system contains a STI-6400 with a DPDT key switch to be mounted on one side of a door or wall; and a similar looking housing, also with a DPDT key switch, but without an alarm for the opposite side of the door. An authorized person with a key can disable the alarm on either side of the door. When disabled, and LED will illuminate, and the door can be opened without setting off the alarm. After passing through the door, the alarm can be armed again from the opposite side. Installation: 1. Follow STI-6400 mounting instructions and set

    switches to the desired positions for alarm timing and volume.

    2. For straight through door or wall installation, mark the center of the 5/16 inch hole in the mounted base, then remove the base from the door or wall.

    3. Drill a 5/16 inch diameter hole through the door or wall at the marked location.

    4. Align the same diameter hole in the secondary unit base to the back side of the door or wall and mount.

    5. Route the wire from the STI-6400 unit through the hole and into the secondary unit.

    6. Attach the 6 wires to the terminal block pins 2 thru 7 matching wire colors on the terminal block label.

    7. Seal the hole around the wires with an effective fire stop material, if required.

    8. Attach the battery in the secondary unit and install the cover.

    9. Cycle the key switch to be sure the LED’s turn “ON” and “OFF”. Leave the LED’s “ON” until ready to test the alarm.

    10. Attach the battery to the STI-6400 and install the cover.

    11. Close the door and test. Operation: 1. With the door closed, turn either key switch to arm

    the alarm. The LED’s on both sides of the door should turn “OFF”.

    2. If the door is opened while the LED’s are “OFF”, then the alarm will sound according to the switch settings of the STI-6400.

    3. To reset the alarm, turn either key to the opposite position (the LED’s will turn “ON”), close the door and turn either key switch again (the LED’s will turn “OFF”).

    4. When the system is armed, authorized passage can be accomplished by turning either key switch until the LED’s turn “ON”, and remove key. The door can now be opened without sounding the alarm. When passage is complete, close the door, turn the key switch (the LED’s will turn “OFF”). The door alarm is once again armed.

    Addendum for STI-6406 with Dual Access Control

    Schematic Diagram:

    13 February 2017

  • - 1 -

    Exit Stopper®STI-6400 Series

    Features

    · Alarm helps prevent unauthorized exits/entries through doors.· Easy to install.· Select volume, alarm duration and delay settings.· May be mounted on top, right, left or next to almost any door.· User can select on-site whether to use an alarm or annunciator.· Less expensive than heavy horizontal bar type units and practical for all

    emergency doors.· Contact STI for custom applications.

    We protect the things that protect you.®

  • - 2 -

    Table of Contents

    · Warnings and Cautions ........................................................................................... Page 2

    · Warranty Information ............................................................................................... Page 2

    · Specifications ......................................................................................................... Page 3

    1. Dimensions ......................................................................................................... Page 3

    2. Polycarbonate ..................................................................................................... Page 3

    3. Electronics .......................................................................................................... Page 3

    4. Remote Horn ...................................................................................................... Page 3

    · Circuit Board Set-Up ............................................................................................... Page 4

    · Terminal Strip Layout ............................................................................................... Page 4

    · Switch Settings ....................................................................................................... Page 4

    · Alarm Feature Description ....................................................................................... Page 5

    · Installation Instructions All Units / STI-6400 ............................................................. Page 5

    · Mounting Options ................................................................................................... Page 6

    · STI-6402 Double Door additional install notes ....................................................... Page 6

    · STI-6403 Remote Horn additional install notes ...................................................... Page 6

    · STI-6404 Double Door with Remote Horn additional install notes .......................... Page 6

    · STI-6405 Exit Stopper with Momentary Reset ....................................................... Page 6

    WarningsAll units are recommended for indoor use, not for outdoor use. Unit must be tested periodically to verify the life of battery. STI recommends you change the 9 Volt battery twice a year. Installer may need to purchase a simple audio-meter, typically available at your local electronics store, to measure the sound in areas where the alarm is expected to be heard during normal noise environment. Results from this test may prove it beneficial to purchase additional exit stopper units. When purchasing a remote unit (STI-6403 or STI-6404) you will need to periodically test the connections to make sure audibles function at a sound level to alert staff. Maximum of three remote alarms may be used in parallel.

    All specifications and information shown are current as of publication and subject to change without notice.

    Warranty Information· Three year guarantee against breakage of polycarbonate in normal use (one year on electro

    mechanical and electronic components).· Electronic warranty form at www.sti-usa.com/wc14

  • - 3 -

    Specifications

    Polycarbonate Enclosure

    Dimensions 5.375” W x 5.375” H x 2 “ D (137mm x 137mm x 51mm)

    Flammability UL94 V-2

    Wall Thickness 0.12 in (3.05mm)

    Electronics: STI-6403 and STI-6404 - Remote Horn Unit

    Power Source 9 VDC operating power* only

    Horn Volume at 1 ft. 95 dB low / 105 dB high

    Stand by Current 0 A

    Alarm Current 50mA at 95 dB/ 200 mA at 105 dB

    * Power source for the STI-6403 and STI-6404 Remote Horn uses a separate power source from the STI-6400 alarm. The Remote Horn contains an internal 9 volt battery. Horn operates when the Form C contact at main unit is activated on alarm.

    Electronics: STI-6400 - All Units

    9 VDC Alkaline or 9V-24VDC wired

    Class II UL Listed transformer

    Horn Volume at 1 ft. 95 dB low / 105 dB high

    Relay Output Form C Dry Contacts 0-30 VDC or VAC, 1 Amp

    Stand by Current 10uA

    Alarm Current 130mA at 95 dB / 200mA at 105 dB Operating Temperature Range

    Power Source

    32° to 113°F (0° to 45°C)

  • - 4 -

    Circuit Board Set-up

    Figure 1TERMINAL BLOCK(SEE BELOW)

    FOR COMPLETE ALARM OPTIONSAND SWITCH SETTINGS SEE CHART

    ON REVERSE SIDE.

    PC BOARD

    JP5

    JP2

    JP4

    JP3

    JP7

    SWITCH

    ALARMDURATION

    ALARM VOLUME SWITCH

    DOOR PROP SWITCH

    ARMING SWITCH

    )( FACTORY DEFAULT SETTINGS

    (FACTORY DEFAULT SETTINGS)

    (ON)

    (ON)

    (OFF)

    (OFF)

    (OFF)

    TERMINAL BLOCK

    FOR COMPLETE ALARM OPTIONSAND SWITCH SETTINGS SEE CHART

    ON REVERSE SIDE.

    PC BOARD

    JP5

    JP2

    JP4

    JP3

    JP7

    SWITCH

    ALARMDURATION

    ALARM VOLUME SWITCH

    TRIP DELAY SWITCH

    ARMING SWITCH

    )( FACTORY DEFAULT SETTINGS

    (FACTORY DEFAULT SETTINGS)

    (ON)

    (ON)

    (OFF)

    (OFF)

    (OFF)

    Switch Settings

    Volume - High (105 dB) at 1 ft. ON*Volume - Low (95 dB) at 1 ft. OFFDuration - 30 Second Alarm OFF* OFF*Duration - 180 Second Alarm OFF ONDuration - Continuous Alarm ON OFFDuration - Annunciator Mode ON ONTrip - Immediate OFF*Door Prop Mode ONArming - Immediate ON*Arming - 30 Second Delay OFF

    FEATURE JP2 JP3 JP4 JP5 JP7

    Slide black lever to desired ON/OFF position as labeled on circuit board.*Factory Settings

    POLYCARBONATE COVER

    POLYCARBONATE BASE

    120 dB HORN

    ALARM DURATION

    ALARM TRIP DELAY

    EXIT DELAYVOLUME

    VIEW OF THE CIRCUIT BOARD

    SCREW6 x 1 1/4 in.

    (2) PROVIDED

    ANCHOR(2) PROVIDED

    BOTTOM SURFACE AS SHOWNWIRES THROUGH NOTCH ONAND ROUTE REED SWITCHREMOVE FRONT COVER

    VIEW SHOWING MAGNET INSTALLATION

    MAGNET

    NC COM NO GD V+ RS1 RS2 KEYSW

    TERMINAL BLOCK WIRING CONNECTIONS

    FORM

    CD

    RYCO

    NTA

    CTS

    REM

    OTE

    PO

    WER

    INPU

    T9-

    24 V

    DC

    REED

    SWIT

    CHTE

    RMIN

    ALS

    KEY

    SWIT

    CHTE

    RMIN

    ALS

    INTERNAL REED SWITCH(RS1)

    ALARM DURATION

    ALARM TRIP DELAY

    EXIT DELAYVOLUME

    VIEW OF THE CIRCUIT BOARD

    MAXIMUM GAP 3/4 in. (19mm) 3/8 in. (9.5mm) ON METAL DOORAND FRAME

    SPACERS (USE AS NECESSARY)NOTE: 2 SPACERS UNDER BOTHMAGNET AND REED SWITCHMUST BE USED ON STEEL DOORS

    4

    3

    2

    1

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTSFLANGES

    TERMINAL STRIP

    9 VOLT BATTERY

    19011 TAMPERPROOF SCREW(1) PROVIDED

    19016 TAMPER WRENCH(1) PROVIDED

    BASE

    19014 MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    NCCOMNOGDV+RS1RS2

    KEYSW

    4

    3

    2

    1

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTSFLANGES

    TERMINAL STRIP

    9 VOLT BATTERY

    19011 TAMPERPROOF SCREW(1) PROVIDED

    19016 TAMPER WRENCH(1) PROVIDEDBASE

    19014 MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    4

    3

    2

    1

    ALARM SOUNDS WHEN DOOR IS OPENED

    EMERGENCY USE ONLY

    ON OFF

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTS

    FLANGES

    TERMINAL STRIP9 VOLT BATTERY

    TAMPERPROOF SCREW(1) PROVIDED

    TAMPER WRENCH(1) PROVIDEDBASE

    MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    TO KEYSWITCH

    KIT-E06402 REED SWITCH(RS2)

    OPTIONAL:TO REMOTE

    HORNSTI-6403

    TERMINAL BLOCK

    VIEW SHOWING INSTALLATION OFADDTIONAL REED SWITCH KIT-E06402

    3/4 in. (19mm)MAXIMUM GAP3/8 in. (9.5mm) ONMETAL DOOR AND FRAME

    MAGNET ASSEMBLY(SEE ABOVE FOR INSTALLATION)

    DOORSWING

    6400 SWING

    MAGNET

    DOOR STOP

    MAGNET MUST BEINSTALLED OPPOSITERAISED RIB ON OUTER COVER

    SCREW6 x 1 1/4 in.(2) PROVIDED

    SPACERS - USEAS NECESSARY

    NOTE: (2) SPACERS MUST BEUSED ON STEEL DOORS

    ANCHOR(2) PROVIDED

    MAGNET

    6400 UNIT

    DOORSWING

    JAMB

    DOOR STOP

    DOOR

    TYPICAL FLUSH MOUNT DOOR JAMBINSTALLATION

    TYPICAL RECESSED MOUNT DOOR JAMBINSTALLATION

    JUMPER WIRE

    All models are shipped with jumper wire installed for use with one reed switch (RS2). If using second reed switch, remove jumper wire and insert second reed switch.

  • - 5 -

    Alarm Feature Description· Volume Switch JP2 - Sets alarm volume to high 105 dB or low 95 dB. · Duration Switch JP3 and JP4 - Amount of time alarm sounds after trip. Arming resets at

    end of duration if door is closed. Alarm will not reset if in continuous mode; alarm will sound until reset with the key or until battery is drained.

    Annunciator mode will sound a series of short beeps until door is closed or 15 seconds.

    · Door Prop Mode Switch JP5 - Once unit is armed with the key (OFF to ON) the alarm will sound if the door remains open for 15 seconds. If the door opens and closes within 15 seconds, the alarm will not sound.

    · Arming Delay Switch JP7 - Delays arming of alarm for 30 seconds. To start arming delay timing, cycle the key switch (OFF to ON). Door must remain closed for 30 seconds for alarm to arm.

    Installation Instructions1. Set switches on circuit board to

    desired alarm settings (Fig. 1).2. If using external power source, use

    Class II UL Listed transformer. 9V battery will be in no-load standby.

    3. Mount main unit on or next to the door using hardware provided. Reed switch may be moved to one of four positions shown in Fig. 2 or you may route the reed switch through the knockout in the bottom of the cover as shown in Fig. 3.

    4. Mount magnet using hardware provided. Magnet must be within ¾” of the reed switch when door is closed. Please refer to figures 7, 8 and 9 for other mounting options.

    Note: When mounting on metal doors or door frame, use plastic spacers provided. Magnet must be within 3/8” of the reed switch when door is closed.

    5. If installing STI-6402, STI-6403, STI-6404 or STI-6405 continue to page 6.

    6. Replace cover by sliding flanges on inside of cover into slots on base, snap closed and replace the tamper screw.

    Figure 3

    POLYCARBONATE COVER

    POLYCARBONATE BASE

    120 dB HORN

    ALARM DURATION

    ALARM TRIP DELAY

    EXIT DELAYVOLUME

    VIEW OF THE CIRCUIT BOARD

    SCREW6 x 1 1/4 in.

    (2) PROVIDED

    ANCHOR(2) PROVIDED

    BOTTOM SURFACE AS SHOWNWIRES THROUGH NOTCH ONAND ROUTE REED SWITCHREMOVE FRONT COVER

    VIEW SHOWING MAGNET INSTALLATION

    MAGNET

    NC COM NO GD V+ RS1 RS2 KEYSW

    TERMINAL BLOCK WIRING CONNECTIONS

    FORM

    CD

    RYCO

    NTA

    CTS

    REM

    OTE

    PO

    WER

    INPU

    T9-

    24 V

    DC

    REED

    SWIT

    CHTE

    RM

    INA

    LS

    KEY

    SWIT

    CHTE

    RM

    INA

    LS

    INTERNAL REED SWITCH(RS1)

    ALARM DURATION

    ALARM TRIP DELAY

    EXIT DELAYVOLUME

    VIEW OF THE CIRCUIT BOARD

    MAXIMUM GAP 3/4 in. (19mm) 3/8 in. (9.5mm) ON METAL DOORAND FRAME

    SPACERS (USE AS NECESSARY)NOTE: 2 SPACERS UNDER BOTHMAGNET AND REED SWITCHMUST BE USED ON STEEL DOORS

    4

    3

    2

    1

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTSFLANGES

    TERMINAL STRIP

    9 VOLT BATTERY

    19011 TAMPERPROOF SCREW(1) PROVIDED

    19016 TAMPER WRENCH(1) PROVIDED

    BASE

    19014 MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    NCCOMNOGDV+RS1RS2

    KEYSW

    4

    3

    2

    1

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTSFLANGES

    TERMINAL STRIP

    9 VOLT BATTERY

    19011 TAMPERPROOF SCREW(1) PROVIDED

    19016 TAMPER WRENCH(1) PROVIDEDBASE

    19014 MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    4

    3

    2

    1

    ALARM SOUNDS WHEN DOOR IS OPENED

    EMERGENCY USE ONLY

    ON OFF

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTS

    FLANGES

    TERMINAL STRIP9 VOLT BATTERY

    TAMPERPROOF SCREW(1) PROVIDED

    TAMPER WRENCH(1) PROVIDEDBASE

    MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    TO KEYSWITCH

    KIT-E06402 REED SWITCH(RS2)

    OPTIONAL:TO REMOTE

    HORNSTI-6403

    TERMINAL BLOCK

    VIEW SHOWING INSTALLATION OFADDTIONAL REED SWITCH KIT-E06402

    3/4 in. (19mm)MAXIMUM GAP3/8 in. (9.5mm) ONMETAL DOOR AND FRAME

    MAGNET ASSEMBLY(SEE ABOVE FOR INSTALLATION)

    DOORSWING

    6400 SWING

    MAGNET

    DOOR STOP

    MAGNET MUST BEINSTALLED OPPOSITERAISED RIB ON OUTER COVER

    SCREW6 x 1 1/4 in.(2) PROVIDED

    SPACERS - USEAS NECESSARY

    NOTE: (2) SPACERS MUST BEUSED ON STEEL DOORS

    ANCHOR(2) PROVIDED

    MAGNET

    6400 UNIT

    DOORSWING

    JAMB

    DOOR STOP

    DOOR

    TYPICAL FLUSH MOUNT DOOR JAMBINSTALLATION

    TYPICAL RECESSED MOUNT DOOR JAMBINSTALLATION

    JUMPER WIRE

    POLYCARBONATE COVER

    POLYCARBONATE BASE

    120 dB HORN

    ALARM DURATION

    ALARM TRIP DELAY

    EXIT DELAYVOLUME

    VIEW OF THE CIRCUIT BOARD

    SCREW6 x 1 1/4 in.

    (2) PROVIDED

    ANCHOR(2) PROVIDED

    BOTTOM SURFACE AS SHOWNWIRES THROUGH NOTCH ONAND ROUTE REED SWITCHREMOVE FRONT COVER

    VIEW SHOWING MAGNET INSTALLATION

    MAGNET

    NC COM NO GD V+ RS1 RS2 KEYSW

    TERMINAL BLOCK WIRING CONNECTIONS

    FORM

    CD

    RYCO

    NTA

    CTS

    REM

    OTE

    PO

    WER

    INPU

    T9-

    24 V

    DC

    REED

    SWIT

    CHTE

    RMIN

    ALS

    KEY

    SWIT

    CHTE

    RMIN

    ALS

    INTERNAL REED SWITCH(RS1)

    ALARM DURATION

    ALARM TRIP DELAY

    EXIT DELAYVOLUME

    VIEW OF THE CIRCUIT BOARD

    MAXIMUM GAP 3/4 in. (19mm) 3/8 in. (9.5mm) ON METAL DOORAND FRAME

    SPACERS (USE AS NECESSARY)NOTE: 2 SPACERS UNDER BOTHMAGNET AND REED SWITCHMUST BE USED ON STEEL DOORS

    4

    3

    2

    1

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTSFLANGES

    TERMINAL STRIP

    9 VOLT BATTERY

    19011 TAMPERPROOF SCREW(1) PROVIDED

    19016 TAMPER WRENCH(1) PROVIDED

    BASE

    19014 MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    NCCOMNOGDV+RS1RS2

    KEYSW

    4

    3

    2

    1

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTSFLANGES

    TERMINAL STRIP

    9 VOLT BATTERY

    19011 TAMPERPROOF SCREW(1) PROVIDED

    19016 TAMPER WRENCH(1) PROVIDEDBASE

    19014 MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    4

    3

    2

    1

    ALARM SOUNDS WHEN DOOR IS OPENED

    EMERGENCY USE ONLY

    ON OFF

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTS

    FLANGES

    TERMINAL STRIP9 VOLT BATTERY

    TAMPERPROOF SCREW(1) PROVIDED

    TAMPER WRENCH(1) PROVIDEDBASE

    MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    TO KEYSWITCH

    KIT-E06402 REED SWITCH(RS2)

    OPTIONAL:TO REMOTE

    HORNSTI-6403

    TERMINAL BLOCK

    VIEW SHOWING INSTALLATION OFADDTIONAL REED SWITCH KIT-E06402

    3/4 in. (19mm)MAXIMUM GAP3/8 in. (9.5mm) ONMETAL DOOR AND FRAME

    MAGNET ASSEMBLY(SEE ABOVE FOR INSTALLATION)

    DOORSWING

    6400 SWING

    MAGNET

    DOOR STOP

    MAGNET MUST BEINSTALLED OPPOSITERAISED RIB ON OUTER COVER

    SCREW6 x 1 1/4 in.(2) PROVIDED

    SPACERS - USEAS NECESSARY

    NOTE: (2) SPACERS MUST BEUSED ON STEEL DOORS

    ANCHOR(2) PROVIDED

    MAGNET

    6400 UNIT

    DOORSWING

    JAMB

    DOOR STOP

    DOOR

    TYPICAL FLUSH MOUNT DOOR JAMBINSTALLATION

    TYPICAL RECESSED MOUNT DOOR JAMBINSTALLATION

    JUMPER WIRE

    Figure 2

    Test AlarmNote: STI recommends testing the alarm in factory settings (see Switch Settings) prior to mounting.

    1. Make sure key switch is in the OFF position.2. Remove tamper screw on the side of the unit using the tamper wrench provided. Remove

    housing cover. Save the tamper wrench for future service and battery replacement (Fig. 2).3. Connect battery.4. Place magnet next to reed switch. Note: For STI-6402 model, insert jumper wire in RS2

    terminals or install second reed switch and place magnet next to reed switches 1 & 2. 5. Turn the key switch to the ON position.6. Move magnet away from reed switch. Unit should alarm immediately.7. Turn unit off with the key to silence alarm.

  • - 6 -

    STI-6402 Double Door Install Notes

    1. If not using extra reed switch, leave jumper wire across terminals RS2 on terminal block.

    2. Determine length needed for reed switch wires. STI provides 1 reed switch with 6 ft. wires. Cut to desired length.

    3. Connect first reed switch in RS1 and second in RS2 (Fig. 5). (Refer to Fig. 1 for additional details.)

    *Note: Alarm will sound when either door is opened.

    STI-6403 Remote Horn Install Notes

    NOTE: WIRING NOT PROVIDED

    NOTE: 14-24 AWG MAY BE USED.

    B

    EXISTING

    EXISTING

    TO STI 6400 CIRCUITBOARD TERMINAL STRIP.

    VIEW IN DIRECTION OF ARROW

    REMOTE HORN WIRE CONNECTIONS

    STI-6403 REMOTE HORN UNIT INSTALLATION

    B

    ROUTE WIRESTHROUGH NOTCH KEY SWITCH

    1. Remove cover.2. Connect two conductor wire (14-24

    AWG) from main unit terminal block pins COM and NO to remote horn unit terminal block. (wire not provided). Units can be set up to 300 ft. apart. Not polarity sensitive (refer to Fig. 1 and Fig. 5 for details).

    3. Connect internal battery.4. Mount similar to main unit with #8 x 1 in.

    screws and anchors if necessary.5. Replace cover and screws.6. Turn key switch to ON position.

    *Note: The ON/OFF key position is opposite from 6400 main unit. Remote horn sounds when main unit alarm is activated.

    STI-6404 Double Door with Remote Horn Install Notes

    The STI-6404 is a combination unit for double doors with a remote horn. Reference the installation instructions for the main unit, the STI-6402 and the STI-6403 for complete installation.

    STI-6405 Exit Stopper with Momentary Reset

    The STI-6405 uses a momentary switch. After initial installation, unit is always on and you do not have to remember to turn it on when you leave a protected area. This model also eliminates having to remember to re-arm it because it is never off.

    When the alarm is triggered, to silence the alarm, insert the key and turn completely to the “RESET” position and hold for 2 seconds, then release. The switch will spring back to its original position and push the key out. To turn the unit off, supply power must be removed.

    RESET

    Figure 4

    Figure 5

    POLYCARBONATE COVER

    POLYCARBONATE BASE

    120 dB HORN

    ALARM DURATION

    ALARM TRIP DELAY

    EXIT DELAYVOLUME

    VIEW OF THE CIRCUIT BOARD

    SCREW6 x 1 1/4 in.

    (2) PROVIDED

    ANCHOR(2) PROVIDED

    BOTTOM SURFACE AS SHOWNWIRES THROUGH NOTCH ONAND ROUTE REED SWITCHREMOVE FRONT COVER

    VIEW SHOWING MAGNET INSTALLATION

    MAGNET

    NC COM NO GD V+ RS1 RS2 KEYSW

    TERMINAL BLOCK WIRING CONNECTIONS

    FORM

    CD

    RYCO

    NTA

    CTS

    REM

    OTE

    PO

    WER

    INPU

    T9-

    24 V

    DC

    REE

    DSW

    ITCH

    TER

    MIN

    ALS

    KEY

    SWIT

    CHTE

    RM

    INA

    LS

    INTERNAL REED SWITCH(RS1)

    ALARM DURATION

    ALARM TRIP DELAY

    EXIT DELAYVOLUME

    VIEW OF THE CIRCUIT BOARD

    MAXIMUM GAP 3/4 in. (19mm) 3/8 in. (9.5mm) ON METAL DOORAND FRAME

    SPACERS (USE AS NECESSARY)NOTE: 2 SPACERS UNDER BOTHMAGNET AND REED SWITCHMUST BE USED ON STEEL DOORS

    4

    3

    2

    1

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTSFLANGES

    TERMINAL STRIP

    9 VOLT BATTERY

    19011 TAMPERPROOF SCREW(1) PROVIDED

    19016 TAMPER WRENCH(1) PROVIDED

    BASE

    19014 MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    NCCOMNOGDV+RS1RS2

    KEYSW

    4

    3

    2

    1

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTSFLANGES

    TERMINAL STRIP

    9 VOLT BATTERY

    19011 TAMPERPROOF SCREW(1) PROVIDED

    19016 TAMPER WRENCH(1) PROVIDEDBASE

    19014 MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    4

    3

    2

    1

    ALARM SOUNDS WHEN DOOR IS OPENED

    EMERGENCY USE ONLY

    ON OFF

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTS

    FLANGES

    TERMINAL STRIP9 VOLT BATTERY

    TAMPERPROOF SCREW(1) PROVIDED

    TAMPER WRENCH(1) PROVIDEDBASE

    MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    TO KEYSWITCH

    KIT-E06402 REED SWITCH(RS2)

    OPTIONAL:TO REMOTE

    HORNSTI-6403

    TERMINAL BLOCK

    VIEW SHOWING INSTALLATION OFADDTIONAL REED SWITCH KIT-E06402

    3/4 in. (19mm)MAXIMUM GAP3/8 in. (9.5mm) ONMETAL DOOR AND FRAME

    MAGNET ASSEMBLY(SEE ABOVE FOR INSTALLATION)

    DOORSWING

    6400 SWING

    MAGNET

    DOOR STOP

    MAGNET MUST BEINSTALLED OPPOSITERAISED RIB ON OUTER COVER

    SCREW6 x 1 1/4 in.(2) PROVIDED

    SPACERS - USEAS NECESSARY

    NOTE: (2) SPACERS MUST BEUSED ON STEEL DOORS

    ANCHOR(2) PROVIDED

    MAGNET

    6400 UNIT

    DOORSWING

    JAMB

    DOOR STOP

    DOOR

    TYPICAL FLUSH MOUNT DOOR JAMBINSTALLATION

    TYPICAL RECESSED MOUNT DOOR JAMBINSTALLATION

    JUMPER WIRE

    Figure 6

  • - 7 -

    Mounting Options

    TYPICAL DOUBLE DOOR INSTALLATION

    STI 6402

    *Note: When mounting reed switch on door and the main unit on wall, wire service loop must be used.

    TYPICAL DOUBLE DOOR INSTALLATIONSTI-6402

    Figure 7

    Figure 8

    Figure 9

    POLYCARBONATE COVER

    POLYCARBONATE BASE

    120 dB HORN

    ALARM DURATION

    ALARM TRIP DELAY

    EXIT DELAYVOLUME

    VIEW OF THE CIRCUIT BOARD

    SCREW6 x 1 1/4 in.

    (2) PROVIDED

    ANCHOR(2) PROVIDED

    BOTTOM SURFACE AS SHOWNWIRES THROUGH NOTCH ONAND ROUTE REED SWITCHREMOVE FRONT COVER

    VIEW SHOWING MAGNET INSTALLATION

    MAGNET

    NC COM NO GD V+ RS1 RS2 KEYSW

    TERMINAL BLOCK WIRING CONNECTIONS

    FORM

    CD

    RYCO

    NTA

    CTS

    REM

    OTE

    PO

    WER

    INPU

    T9-

    24 V

    DC

    REED

    SWIT

    CHTE

    RMIN

    ALS

    KEY

    SWIT

    CHTE

    RMIN

    ALS

    INTERNAL REED SWITCH(RS1)

    ALARM DURATION

    ALARM TRIP DELAY

    EXIT DELAYVOLUME

    VIEW OF THE CIRCUIT BOARD

    MAXIMUM GAP 3/4 in. (19mm) 3/8 in. (9.5mm) ON METAL DOORAND FRAME

    SPACERS (USE AS NECESSARY)NOTE: 2 SPACERS UNDER BOTHMAGNET AND REED SWITCHMUST BE USED ON STEEL DOORS

    4

    3

    2

    1

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTSFLANGES

    TERMINAL STRIP

    9 VOLT BATTERY

    19011 TAMPERPROOF SCREW(1) PROVIDED

    19016 TAMPER WRENCH(1) PROVIDED

    BASE

    19014 MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    NCCOMNOGDV+RS1RS2

    KEYSW

    4

    3

    2

    1

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTSFLANGES

    TERMINAL STRIP

    9 VOLT BATTERY

    19011 TAMPERPROOF SCREW(1) PROVIDED

    19016 TAMPER WRENCH(1) PROVIDEDBASE

    19014 MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    4

    3

    2

    1

    ALARM SOUNDS WHEN DOOR IS OPENED

    EMERGENCY USE ONLY

    ON OFF

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTS

    FLANGES

    TERMINAL STRIP9 VOLT BATTERY

    TAMPERPROOF SCREW(1) PROVIDED

    TAMPER WRENCH(1) PROVIDEDBASE

    MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    TO KEYSWITCH

    KIT-E06402 REED SWITCH(RS2)

    OPTIONAL:TO REMOTE

    HORNSTI-6403

    TERMINAL BLOCK

    VIEW SHOWING INSTALLATION OFADDTIONAL REED SWITCH KIT-E06402

    3/4 in. (19mm)MAXIMUM GAP3/8 in. (9.5mm) ONMETAL DOOR AND FRAME

    MAGNET ASSEMBLY(SEE ABOVE FOR INSTALLATION)

    DOORSWING

    6400 SWING

    MAGNET

    DOOR STOP

    MAGNET MUST BEINSTALLED OPPOSITERAISED RIB ON OUTER COVER

    SCREW6 x 1 1/4 in.(2) PROVIDED

    SPACERS - USEAS NECESSARY

    NOTE: (2) SPACERS MUST BEUSED ON STEEL DOORS

    ANCHOR(2) PROVIDED

    MAGNET

    6400 UNIT

    DOORSWING

    JAMB

    DOOR STOP

    DOOR

    TYPICAL FLUSH MOUNT DOOR JAMBINSTALLATION

    TYPICAL RECESSED MOUNT DOOR JAMBINSTALLATION

    JUMPER WIRE

    POLYCARBONATE COVER

    POLYCARBONATE BASE

    120 dB HORN

    ALARM DURATION

    ALARM TRIP DELAY

    EXIT DELAYVOLUME

    VIEW OF THE CIRCUIT BOARD

    SCREW6 x 1 1/4 in.

    (2) PROVIDED

    ANCHOR(2) PROVIDED

    BOTTOM SURFACE AS SHOWNWIRES THROUGH NOTCH ONAND ROUTE REED SWITCHREMOVE FRONT COVER

    VIEW SHOWING MAGNET INSTALLATION

    MAGNET

    NC COM NO GD V+ RS1 RS2 KEYSW

    TERMINAL BLOCK WIRING CONNECTIONS

    FORM

    CD

    RYCO

    NTA

    CTS

    REM

    OTE

    PO

    WER

    INPU

    T9-

    24 V

    DC

    REED

    SWIT

    CHTE

    RMIN

    ALS

    KEY

    SWIT

    CHTE

    RMIN

    ALS

    INTERNAL REED SWITCH(RS1)

    ALARM DURATION

    ALARM TRIP DELAY

    EXIT DELAYVOLUME

    VIEW OF THE CIRCUIT BOARD

    MAXIMUM GAP 3/4 in. (19mm) 3/8 in. (9.5mm) ON METAL DOORAND FRAME

    SPACERS (USE AS NECESSARY)NOTE: 2 SPACERS UNDER BOTHMAGNET AND REED SWITCHMUST BE USED ON STEEL DOORS

    4

    3

    2

    1

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTSFLANGES

    TERMINAL STRIP

    9 VOLT BATTERY

    19011 TAMPERPROOF SCREW(1) PROVIDED

    19016 TAMPER WRENCH(1) PROVIDED

    BASE

    19014 MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    NCCOMNOGDV+RS1RS2

    KEYSW

    4

    3

    2

    1

    NCCOMNOGDV+RS1RS2

    KEYSWSLOTS

    FLANGES

    TERMINAL STRIP

    9 VOLT BATTERY

    19011 TAMPERPROOF SCREW(1) PROVIDED

    19016 TAMPER WRENCH(1) PROVIDEDBASE

    19014 MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    4

    3

    2

    1

    ALARM SOUNDS WHEN DOOR IS OPENED

    EMERGENCY USE ONLY

    ON OFF

    NCCOMNOGDV+RS1RS2

    KEYSW

    SLOTS

    FLANGES

    TERMINAL STRIP9 VOLT BATTERY

    TAMPERPROOF SCREW(1) PROVIDED

    TAMPER WRENCH(1) PROVIDEDBASE

    MOUNTING SCREW(4) PROVIDED

    REED SWITCHMOUNTING LOCATIONS

    (LABELED 1-4)

    COVER

    TO KEYSWITCH

    KIT-E06402 REED SWITCH(RS2)

    OPTIONAL:TO REMOTE

    HORNSTI-6403

    TERMINAL BLOCK

    VIEW SHOWING INSTALLATION OFADDTIONAL REED SWITCH KIT-E06402

    3/4 in. (19mm)MAXIMUM GAP3/8 in. (9.5mm) ONMETAL DOOR AND FRAME

    MAGNET ASSEMBLY(SEE ABOVE FOR INSTALLATION)

    DOORSWING

    6400 SWING

    MAGNET

    DOOR STOP

    MAGNET MUST BEINSTALLED OPPOSITERAISED RIB ON OUTER COVER

    SCREW6 x 1 1/4 in.(2) PROVIDED

    SPACERS - USEAS NECESSARY

    NOTE: (2) SPACERS MUST BEUSED ON STEEL DOORS

    ANCHOR(2) PROVIDED

    MAGNET

    6400 UNIT

    DOORSWING

    JAMB

    DOOR STOP

    DOOR

    TYPICAL FLUSH MOUNT DOOR JAMBINSTALLATION

    TYPICAL RECESSED MOUNT DOOR JAMBINSTALLATION

    JUMPER WIRE

  • - 8 -

    Inst. 6400 SEPT2014Printed in USA Subject to change without notice.

    2306 Airport Rd • Waterford, MI 48327, USAPhone: 248-673-9898 • Fax: 248-673-1246

    [email protected] • www.sti-usa.com