Step by Step Installation Guide Hep 2 O Room Pack 1 of 5 Wavin Limited | Registered Office | Edlington Lane | Doncaster | DN12 1BY | T: 0844 856 5152 | E-mail [email protected] | Connect to better at www.wavin.co.uk Installation Steps Step 1 Place edge expansion foam round room perimeter, starting halfway along a straight section. As you do this, peel off the backing paper and stick the expansion foam to the wall. NOTE: Do NOT remove the backing paper from the scored top section - not necessary for yellow expansion foam. Ensure that the expansion foam is tightly butted together at any joints and that it is pushed back into corners. Step 2 Lay insulation panels, using bonded arrangement to create staggered joints. NOTE: These panels are to be independently sourced – NOT supplied with the Room Pack If required by the insulation, cover it with a suitable DPM. Ensure integral gaiter on edge expansion foam is lying flat on top of insulation panels and plastic sheeting. Slit gaiter at corners to allow it to lie flat. Tape the gaiter edge down to the prepared floor. Contents 15mm UFH Pipe Coil 300 Pipe Staples 25m Roll of Edge Expansion Foam Programmable Thermostat 2 x Isolation Valves Flow Watch Thermostat Control Pack Single Circuit Fittings Pack

Step Step Installation ie · Step Step Installation ie ep 2 oo a 5 of 5 Wain iite Registered Offlce Edlington Lane Doncaster DN12 1B T: 044 5 5152 E-mail infowavin.co.uk Connet to

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Step Step Installation ie · Step Step Installation ie ep 2 oo a 5 of 5 Wain iite Registered Offlce Edlington Lane Doncaster DN12 1B T: 044 5 5152 E-mail infowavin.co.uk Connet to

Step by Step Installation Guide Hep2O Room Pack 1 of 5

Wavin Limited | Registered Office | Edlington Lane | Doncaster | DN12 1BY | T: 0844 856 5152 | E-mail [email protected] |

Connect to better at www.wavin.co.uk

Installation Steps

Step 1

Place edge expansion foam round room perimeter, starting halfway along a straight section.As you do this, peel off the backing paper and stick the expansion foam to the wall.

NOTE: Do NOT remove the backing paper from the scored top section - not necessary for yellow expansion foam.

Ensure that the expansion foam is tightly butted togetherat any joints and that it is pushed back into corners.

Step 2

Lay insulation panels, using bonded arrangement to create staggered joints.

NOTE: These panels are to be independently sourced – NOT supplied with the Room Pack

If required by the insulation, cover it with a suitable DPM.Ensure integral gaiter on edge expansion foam is lying flat on top of insulation panels and plastic sheeting.Slit gaiter at corners to allow it to lie flat.Tape the gaiter edge down to the prepared floor.

Contents

15mm UFH Pipe Coil 300 Pipe Staples 25m Roll of Edge

Expansion Foam Programmable

Thermostat

2 x Isolation Valves Flow Watch Thermostat Control Pack Single Circuit Fittings Pack

Page 2: Step Step Installation ie · Step Step Installation ie ep 2 oo a 5 of 5 Wain iite Registered Offlce Edlington Lane Doncaster DN12 1B T: 044 5 5152 E-mail infowavin.co.uk Connet to

Step by Step Installation Guide Hep2O Room Pack 2 of 5

Wavin Limited | Registered Office | Edlington Lane | Doncaster | DN12 1BY | T: 0844 856 5152 | E-mail [email protected] |

Connect to better at www.wavin.co.uk

Step 3

Plan pipe layoutRECOMMENDED PIPE SPACING: 200mm centres.

Start pattern from nearest point to location of manifold.Use spiral [recommended] or serpentine pattern: serpentine pipe runs normally lie parallel to longest edge of room.Avoid floor areas where heating NOT required.

EXAMPLES: under permanent fixtures such as kitchen appliances/cupboards. Do NOT install heating pipe here.

Step 4

Place and fix pipeNOTE: This can be completed faster if installed by two people – one to uncoil the pipe, one to staple pipe in position

Remove Wavin cutter from pipe reel, strip off blue wrap, and find pipe end from centre of reel.Leave tail long enough to reach manifold.For spiral pattern: begin approx 150-200mm from the wall then begin laying pipe at 400mm centres to middle of room – then return out, leaving pipe at 200mm centres.Use edge of gaiter from edge foam as guide for pipe spacing from walls.Fix staples by hand, or with staple gun while standing.Staple pipe at approx. half-metre intervals on straights.Keep pipe tight, to within 5mm variance.At each loop turn, secure pipe with three staples, including oneat apex of turn.

IMPORTANT NOTE: To avoid over stressing pipe, do NOT make turn tighter than 200mm diameter

Where pipe tails are below manifold location, clip each pipe into a curved pipe support.

Page 3: Step Step Installation ie · Step Step Installation ie ep 2 oo a 5 of 5 Wain iite Registered Offlce Edlington Lane Doncaster DN12 1B T: 044 5 5152 E-mail infowavin.co.uk Connet to

Step by Step Installation Guide Hep2O Room Pack 3 of 5

Wavin Limited | Registered Office | Edlington Lane | Doncaster | DN12 1BY | T: 0844 856 5152 | E-mail [email protected] |

Connect to better at www.wavin.co.uk

Step 5

Assemble the Manifold

Connect to 22mm heating supply.

Step 6

Mount the Manifold

Manifold should be located closeto the pipe circuit to be installed.

Flow watch thermostat

1" 15mm adaptor

Control pack

Isolation valves

15mm spigot elbow

Ensure bracket is vertical, and pump is horizontal

Page 4: Step Step Installation ie · Step Step Installation ie ep 2 oo a 5 of 5 Wain iite Registered Offlce Edlington Lane Doncaster DN12 1B T: 044 5 5152 E-mail infowavin.co.uk Connet to

Step by Step Installation Guide Hep2O Room Pack 4 of 5

Wavin Limited | Registered Office | Edlington Lane | Doncaster | DN12 1BY | T: 0844 856 5152 | E-mail [email protected] |

Connect to better at www.wavin.co.uk

Step 7

Connect to system

The system can be installed with or without boiler interlock (Option A belowor B on the next page). Please follow the relevant set of Connection Diagrams for your systemconfiguration, paying close attention to the diagram notes.

A – With boiler interlock

Plumbing connections

All components must be installedand earthed in accordance withlocal regulations.

Electrical connections

The UFH Thermostat should notbe installed in Wet Rooms, e.g. Bathrooms. When controlling Wet Rooms, the UFH Thermostat should be located in a suitable location outside of the Wet Room, with the Remote Sensor Probe installed inside the Wet Room.

Radiator thermostatas existing

UFH thermostat

UFHControlPack

Flow watch thermostatset to 75oCRadiators as existing

Flow pipe

Return pipe

UFH zone valve required

Radiatorzone valveas existing

To Boiler

230V AC – 50Hz Supply Taken from the Heating

System Fused Spur

To Boiler Interlock Terminals

UFH zone valve(Not Supplied)

Junction Box(Not Supplied)

Terminals for remote temperature sensor (See thermostat instructions for details)

UFH thermostat

Flow watch thermostat

UFH pump(Part of Control Pack assembly)

Page 5: Step Step Installation ie · Step Step Installation ie ep 2 oo a 5 of 5 Wain iite Registered Offlce Edlington Lane Doncaster DN12 1B T: 044 5 5152 E-mail infowavin.co.uk Connet to

Step by Step Installation Guide Hep2O Room Pack 5 of 5

Wavin Limited | Registered Office | Edlington Lane | Doncaster | DN12 1BY | T: 0844 856 5152 | E-mail [email protected] |

Connect to better at www.wavin.co.uk

July

17

B – Without boiler interlock

Plumbing connections

All components must be installedand earthed in accordance withlocal regulations.

Electrical connections

Radiator thermostatas existing

UFHControlPack

Radiatorzone valveas existing

Radiators as existing

Flow pipe

Return pipe

Flow watchthermostat*

set to 35oC

To Boiler

230V AC – 50Hz Supply Via 3A Fused Spur

Junction box(Not Supplied)

Flow watch thermostat

UFH pump(Part of Control Pack assembly)