3
DETAIL A SCALE 1 / 4 A Steel Wall Sensor Details AUTHOR: Matt DiDomizio COMPANY: University of Waterloo REVISION: 02 DATE: May 1, 2016 SHEET SIZE: C SHEET NUMBER: 1 OF 3 DRAWING SCALE: As indicated (all dimensions in inches unless otherwise stated). Front and Rear Views of Wall Frame with Steel Wall Sensor Installed SCALE: 1/10 High Temperature Silicone Gasket Unistrut P1000 1 5/8" Channel Unistrut P1026 Ninety Degree Fitting Unistrut P1065 Flat Plate Fitting Note: All channel fittings connected using 1/2" spring channel nuts (P1006) and 1/2" hex head bolts, 1 1/2" in length.

Steel Wall Sensor Details - University of Waterloo

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Steel Wall Sensor Details - University of Waterloo

DETAIL A

SCALE 1 / 4

A

Steel Wall Sensor Details

AUTHOR: Matt DiDomizio

COMPANY: University of Waterloo

REVISION: 02

DATE: May 1, 2016

SHEET SIZE: C

SHEET NUMBER: 1 OF 3

DRAWING SCALE: As indicated (all dimensions in inches unless

otherwise stated).

Front and Rear Views of Wall Frame with Steel Wall Sensor Installed

SCALE: 1/10

High Temperature

Silicone Gasket

Unistrut P1000

1 5/8" Channel

Unistrut P1026

Ninety Degree Fitting

Unistrut P1065

Flat Plate Fitting

Note: All channel fittings connected using

1/2" spring channel nuts (P1006) and

1/2" hex head bolts, 1 1/2" in length.

Page 2: Steel Wall Sensor Details - University of Waterloo

DETAIL A

SCALE 1 / 5

A

Steel Wall Sensor Details

AUTHOR: Matt DiDomizio

COMPANY: University of Waterloo

REVISION: 02

DATE: May 1, 2016

SHEET SIZE: C

SHEET NUMBER: 2 OF 3

DRAWING SCALE: As indicated (all dimensions in inches unless

otherwise stated).

Front and Rear Views of the Steel Wall Sensor

SCALE: 1/10

25.00 (TYP)

75.00

Hex bolts, 9/16" (TYP)

10.5 (TYP)

Details:

The steel wall sensor is constructed using 3 sheets of 18 ga steel, each measuring 75 in by 25 in, bolted to a Unistrut steel frame.

All bolting hardware is fitted loosly in order to avoid buckling as the material thermally expands under fire exposure.

The total mass of the sheet steel is approximately 12 kg, and the total mass of the entire frame including bolting hardware is approximately 129 kg.

With a total area of 75 in by 75 in (3.629 m2), a total mass of 129 kg, and density of 7900 kg/m3, the effective thickness of the wall is 4.5 mm.

Thermocouples are resistance welded to the back side of the steel sheet in the location indicated.

9.50 9.5025.00 15.5015.50

9.50

9.50

56.00

4.6875

9.3750

9.3750

9.3750

9.3750

9.3750

9.3750

9.3750

4.6875

Thermocouple Locations

Page 3: Steel Wall Sensor Details - University of Waterloo

Steel Wall Sensor Details

AUTHOR: Matt DiDomizio

COMPANY: University of Waterloo

REVISION: 02

DATE: May 1, 2016

SHEET SIZE: C

SHEET NUMBER: 3 OF 3

DRAWING SCALE: As indicated (all dimensions in inches unless

otherwise stated).

1.88

2.00

R.25

.5625

.8125

Unistrut P1026 Ninety Degree Fitting

SCALE: 1/1

1.625

1.625

3.50

.5625.8125

Unistrut P1065 Flat Plate Fitting

SCALE: 1/1

Unistrut P1000 1 5/8" Channel

SCALE: 1/1

Unistrut P1000 1 5/8" Channel (Details)

SCALE: 2/1

1.625

1.625

.281

1.415