45
midas Gen Tutorial Eur ocode 3 - Design of M ulti-Story Steel Buil ding MIDAS Information Technology Co., Ltd. Program Version V7.4.1 Program License Commercial, Trial Revision Date Dec., 19, 2008 Eurocode 3 - Design of Multi-Story Steel Building

Steel Design EC3

Embed Size (px)

Citation preview

  • 5/22/2018 Steel Design EC3

    1/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.

    Program Version V7.4.1

    Program License Commercial, Trial

    Revision Date Dec., 19, 2008

    Eurocode 3 - Design of Multi-Story Steel Building

  • 5/22/2018 Steel Design EC3

    2/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Steel Design F eatures in midas Gen

    Gen provides code checking for beams, columns and bracings as per Eurocode 3: 2005.

    Both Ultimate and Serviceability limit states are checked.

    Load combinations as per Eurocode 3 are automaticaly generated.

    Static wind loads as per Eurocode 1-4: 2005 can be automatically assigned.

    Static seismic loads and response spectrum function as per Eurocode 8-1: 2004 are available.

    Available Section profiles include:

    Angle, Channel, I -Shape, T-Shape, Box, Pipe, Double L, Double C

    Joint Connection design is not currently available.

    Imperfections needs to be manually considered.

    Second-order effects can be considered.

    Internal forces and moments are determined using elastic global analysis.

    Composite beam design is provided in our sister product midas Civil.

    Capacity design as per EN 1998 will be available in the next version planned for released in Spring 2009.

  • 5/22/2018 Steel Design EC3

    3/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.3

    Contents

    Part 1. EC3 Design in Gen

    I.Ultimate Limit State Check

    Material Properties

    Section table for the application of Ultimate Limit State Check

    Resistance of cross-sections

    Buckling resistance of members

    II. Serviceability Limit State CheckVertical deflections

    Horizontal deflections

    Part 2. Tutorial

    Eurocode 3 Steel Code Check Procedure:

    1.Analyze the model.

    2.Select the design code.

    3.Generate load combinations.

    4.Enter design parameters (Unbraced Length, Moment Factor, etc).

    5.Enter deflection limits.

    6.Check design results.

    7.Change and update the designed sections.

  • 5/22/2018 Steel Design EC3

    4/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    I. Ultimate Limit State Check

    Part 1. EC3 Design in Gen

  • 5/22/2018 Steel Design EC3

    5/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    The nominal values of the yield strength (fy) and the ultimate strength (fu) for structural steel

    Material Properties

    Steel Grade

    t 40mm t > 40mm

    fy

    (N/mm2)

    fu

    (N/mm2)

    fy

    (N/mm2)

    fu

    (N/mm2)

    S235

    S275

    S355

    S450

    235

    275

    355

    440

    360

    430

    510

    550

    215

    255

    335

    410

    360

    410

    470

    550

    Modulus of Elasticity = 210,000 N/mm2

    Poissons Ratio = 0.3

    Thermal Coefficient = 12 x10-6 /oC

    Weight Density = 76.98 kN/m3

  • 5/22/2018 Steel Design EC3

    6/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Section table for the application of Ultimate Limit State Check

    Note:

    (1) Torsional Buckli ng and Torsional-F lexural Buckli ng are not evaluated.

    (2) The thickness of two webs should be identical, and the member type should be column forthe weak axi s shear buckl ing check.

    (3) FB: F lexural Buckling, SB: Shear Buckling, LTB: Lateral-Torsional Buckling

    Cross section

    Limit States

    Yielding FB (1) SB LTBStrong axis Weak axis

    I sectionDoubly Symmetric N/A

    Singly Symmetric N/A N/A

    Box (2) N/A

    Angle N/A N/A N/A

    Channel N/A N/A

    Tee N/A N/A N/A

    Double Angle N/A N/A N/A

    Double Channel N/A N/A

    Pipe N/A N/A N/A

    Solid Rectangle N/A N/A N/A

    Solid Round N/A N/A N/A

    U-Rib N/A N/A N/A N/A N/A

  • 5/22/2018 Steel Design EC3

    7/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Tension

    Design tension resistance

    The design ultimate resistance of the net cross-section at holes for fasteners is not considered in midasGen.

    Resistance of cross-sections

    Compression

    Design compression resistance

    In the case of unsymmetrical Class 4 sections, the additional moment due to the eccentricity of thecentroidal axis of the effective section is considered in midas Gen.

  • 5/22/2018 Steel Design EC3

    8/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Bending moment

    Design bending resistance

    Shear

    Design shear resistance in the absence of tor sion

    The shear area Av is calculated based on the clause 6.2.6 (3) as per EN1993-1-1

    Rolled I and H sections, load parallel to web: but not less than

    Design elastic shear resistance is not applied.

    Resistance of cross-sections

  • 5/22/2018 Steel Design EC3

    9/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Shear Buckling

    The shear buckling resistance for webs without intermediate stiffeners is calculated, according to

    section 5 of EN 1993-1-5, if

    For steel grades up to and including S460.

    For higher steel grades

    Design resistance

    Stiffener design to resist shear buckling is not provided in midas Gen.

    Stiffener type for end supports is assumed as a non-rigid end post.

    It is assumed that the length of an unstiffened plate, ais the same as the unbraced length.

    Non-r igid end post

    Resistance of cross-sections

  • 5/22/2018 Steel Design EC3

    10/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Torsion

    The torsional resistance is not checked.

    Bending and Shear

    The effect of shear force on the moment resistance is considered.

    Where the shear force is less than half the plastic shear resistance, its effect on the moment resistance

    is neglected.

    Where

    I -cross-sections with equal f langes and bending about the major ax is

    Torsion is not considered when calculating .

    For the other cases

    RdplED VV ,5.0

    RdcRdV MM ,, )1(

    Resistance of cross-sections

  • 5/22/2018 Steel Design EC3

    11/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Bending and Axial Force

    The effect of axial force on the moment resistance is considered.

    Class 1 and 2 cross sections

    For doubly symmetri cal I - and H-sections, allowance is not made for the effect of the axial force on the

    plastic resistance moment about the y-y axis when both the fol lowing cri ter ia are satisfi ed:

    For doubly symmetri cal I - and H-sections, allowance is not made for the effect of the axial force on the

    plastic resistance moment about the z-z axi s when:

    The fol lowing equations are used for standard roll ed I or H sections and for welded I or H sections with

    equal fl anges.

    Resistance of cross-sections

  • 5/22/2018 Steel Design EC3

    12/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Bending and Axial Force (contd.)

    For bi-axi al bending both the fol lowing cri ter ia are used:for Class 1 & 2 sections

    for Class 1, 2, 3 & 4 sections

    a)

    b)

    Bending, Shear and Axial Force

    Where the shear force exceeds 50% of the plastic shear resistance, its effect on the moment of resistance is

    reflected in the formula above.

    Mpl,y,Rd and Mpl,z,Rd are replaced by My,v,Rd and Mz,v,Rd respectively in the following equations to consider

    shear effect in the above criterion a).

    My,Rd and Mz,Rd are replaced by My,v,Rd and Mz,v,Rd respectively in the above criterion b)

    to consider shear effect.

    Resistance of cross-sections

  • 5/22/2018 Steel Design EC3

    13/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Uniform members in compression

    For slenderness or for the buckling effects are ignored.

    Flexural buckling is checked for the L, C, I, T, Box, Pipe, Double L, and Double C section.

    Torsional and torsional-flexural buckling is not checked.

    Design buckling resistance

    Buckling resistance of members

    is the elastic critical force for the relevant buckling mode based on the gross cross sectional properties.

  • 5/22/2018 Steel Design EC3

    14/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Uniform members in bending

    For the uniform and doubly symmetric I cross-sections only, the lateral torsional buckling check isprovided.

    It is assumed that the section is loaded through its shear center, and the boundary conditions at each

    end are both restrained against lateral movement and restrained against rotation about the

    longitudinal axis.

    For slenderness or for the lateral torsional buckling effects are ignored.

    Buckling resistance of members

    Mcris the elastic critical moment for lateral-torsional buckling.

    The value of C 1depends on the moment distr ibu tion along the

    member, which is calculated based on the table in the following page.

    : Warping constant

  • 5/22/2018 Steel Design EC3

    15/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Uniform members in bending (Continued)

    If the member type is column, C1 is calculated based on the table below. EN 1993-1-1: 1992 Annex F

    Buckling resistance of members

    k C1

    +1

    1.0 1.000

    0.7 1.000

    0.5 1.000

    +3/4

    1.0 1.141

    0.7 1.270

    0.5 1.305

    +1/2

    1.0 1.323

    0.7 1.473

    0.5 1.514

    +1/4

    1.0 1.563

    0.7 1.739

    0.5 1.788

    k C1

    0

    1.0 1.879

    0.7 2.092

    0.5 2.150

    -1/4

    1.0 2.281

    0.7 2.538

    0.5 2.609

    -1/2

    1.0 2.704

    0.7 3.009

    0.5 3.093

    -3/4

    1.0 2.927

    0.7 3.009

    0.5 3.093

    -1

    1.0 2.752

    0.7 3.063

    0.5 3.149

    M M

  • 5/22/2018 Steel Design EC3

    16/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Uniform members in bending (Continued)

    If the member type is beam, C1 is calculated based on the table below.

    Buckling resistance of members

  • 5/22/2018 Steel Design EC3

    17/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Uniform members in bending (Continued)

    Design buckl ing resistance

    The method in the Clause 6.3.2.3 and 6.3.2.4 of EC3 are not considered.

    Buckling resistance of members

  • 5/22/2018 Steel Design EC3

    18/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Uniform members in bending and axial compression

    For members which are subjected to combined bending and axial compression, the resistance to

    lateral and lateral-torsional buckling is verified by the following criteria.

    When the design axial force, NEd is larger than Ncr,z or Ncr,TF, the criteria above are not applied.

    General method of the clause 6.3.4 is not considered.

    Buckling resistance of members

    kyy, kyz, kzy, kzzare the interaction factors. These values are obtained from Annex A in EN 1993-1-1: 2005.

    Cmy, Cmzand CmLTin Annex A can be either user-defined or auto-calculated.

  • 5/22/2018 Steel Design EC3

    19/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    ii. Serviceability Limit State Check

  • 5/22/2018 Steel Design EC3

    20/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Vertical deflections

    Vertical deflection can be checked for beam members.

    Remaining total deflection (wmax) caused by the permanent and variable actions is automatically

    checked based on the serviceability load combinations.

    The default limit value is set to L/250.

    The deflection due to the variable actions can be checked manually by adding load combinationconsisting of variable actions and changing the limit value.

  • 5/22/2018 Steel Design EC3

    21/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Horizontal deflections

    Horizontal deflection can be checked for column members.

    Horizontal displacement over a story height Hi is automatically checked based on the serviceability

    load combinations.

    The default limit value is set to Hi/300.

    Overall horizontal displacement over the building height H should be checked separately.

    Dynamic effects

    The vibration of structures is not checked.

    E d 3 D i f M l ti St St l B il di

  • 5/22/2018 Steel Design EC3

    22/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    Design of Multi-Story Steel Building

    Part 2. Tutori al

    id G T t i l E d 3 D i f M l ti St St l B il di

  • 5/22/2018 Steel Design EC3

    23/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.23

    Eur ocode 3 Steel Design Methods

    midas Gen provides the following two methods:

    1. The program finds optimal sections for gr avity loads (Design > Steel Optimal Design) and

    also finds optimal sections for lateral loads (Design> Displacement Optimal Design). With

    the combined use of the two, the user shoul d fi nd optimal sections.

    2. The program checks strength and serviceabil i ty based on the sections def ined by the user

    and the design code selected by the user (Design > Steel Code Check). Also, the program

    searches and proposes sections which satisfy the design conditions entered by the user.

    Then the user can update the sections referr ing to the sections proposed by the program.

    In this tutorial, method 2 is presented.

    id G T t i l E d 3 D i f M l ti St St l B il di

  • 5/22/2018 Steel Design EC3

    24/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.24

    5,000

    Details of the example building

    1F

    2F

    3F

    4F

    5F

    ROOF

    Figure 1. Elevation (unit: mm)

    Figure 2. Structural Plan (2~Roof) (unit: mm)

    4,000

    4,000

    4,000

    4,000

    2,500

    7,500 7,5007,500 7,500 7,500 7,500 7,500

    2,500

    2,

    500

    2,500

    2,500

    2,500

    2,500

    id G T t i l Eur ocode3 Design of M ul ti Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    25/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.25

    Structural SystemApplied Codes

    Applied Wind Load: Eurocode 1 (2005)

    Applied Seismic Load: Eurocode 8 (2004)

    Steel Design Code: Eurocode 3 (2005)

    Self Weight

    Floor loads

    For floor 2~5

    Superimposed Dead Load: 3.7 kN/m2

    Live Load: 4 kN/m2

    For roof

    Superimposed Dead Load: 5 kN/m2

    Live Load: 1.5kN/m2

    Wind loads

    Basic Wind Velocity: 26 m/s

    Terrain Category: II

    Seismic loads

    Ground Type: B

    Applied Loads

    Load Name Details

    StaticLoadCases

    1 Self Weight Self Weight

    2 SID Superimposed Dead Load

    3 Live Load Live Load

    4 Wind X-dirWind Load

    (in the global X-direction)

    5 Wind Y-dir Wind Load(in the global Y-direction)

    ResponseSpectrum

    LoadCases

    6 RXSeismic Load

    (in the global X-direction)

    7 RYSeismic Load

    (in the global Y-direction)

    Unit Load Cases

    Bracing system

    Materials

    Beam, Column and Brace: S275

    midasGen Tutor ial Eur ocode3 Design of M ul ti Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    26/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.26

    Section ID DB Section Size

    4 UNI HEB 240

    5 UNI HEB 300

    Section ID DB Section Size

    1 UNI IPE 500

    2 UNI IPE 600

    3 UNI IPE 450

    Column

    Brace

    Beam

    Section ID DB Section Size

    6 UNI HEA 260

    Applied Sections

    These are the sections assumed before design updates.

    midasGen Tutor ial Eur ocode3 Design of M ul ti Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    27/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.27

    Step 1. Open the model fi le and perform analysis

    1. Open EC3 design_start model.mgb

    2. Analysis > Perform Analysis

    1. Design > Steel Design Parameter > Design Code

    2. Design Code: Eurocode3:05

    3. Click on OK button.

    Step 2. Steel Design Code

    2

    3

    midasGen Tutor ial Eur ocode3 Design of M ul ti Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    28/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.28

    Step 3: Generate Load Combinations (1)

    1. Result > Combinations

    2. Click on Steel Design Tab.

    3. Click Auto Generation button.

    4. Option: Add

    5. Code Selection: Steel

    6. Design Code: Eurocode3:05

    7. Gamma G: 1.35, Gamma Q: 1.5

    8. Click on OK button.

    9. Click on Close button.

    4

    5

    6

    8

    The program automatically creates design load combinations

    which can bealso modified or deleted by theuser.

    7

    midasGen Tutor ial Eur ocode3 - Design of M ul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    29/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.29

    Step 3: Generate Load Combinations (2)

    2

    3

    9

    midasGen Tutor ial Eur ocode3 - Design of M ul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    30/45

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.30

    Step 4: Enter Unbraced Length

    1. View > Select > I dentity

    2. Select Type: Section

    3. Select 1: IPE 500 & IPE 600.

    4. Click on Add button and Close button.

    5. Design > General Design Parameter >Unbraced Length

    6. Option: Add/Replace

    7. Laterally Unbraced Length, Lb = 2.5

    8. Click on Apply button and Close button.

    2

    3

    4

    6

    5

    7

    8

    midasGen Tutor ial Eur ocode3 - Design of M ul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    31/45

    midas Gen Tutor ial Eur ocode 3 Design of Mul ti Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.31

    Step 5: Enter Equivalent Uniform Moment Factor (Cmy, Cmz)

    1. View > Select > Select All

    2. Design > General Design Parameter >Equivalent Unif orm Moment Factor

    3. Option: Add/Replace

    4. Check on Calculate by Program

    5. Click on Apply button and Close button.

    3

    4

    5

    midasGen Tutor ial Eur ocode3 - Design of M ul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    32/45

    midas Gen Tutor ial Eur ocode 3 Design of Mul ti Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.32

    Step 6: Enter Equivalent Moment Factor (CmLT)

    6

    7

    8

    1. View > Select > I dentity

    2. Select Type: Element Type

    3. Select BEAM.

    4. Click on Add button and Close button.

    5. Design > Steel Design Parameter > Equivalent Moment Factor

    6. Option: Add/Replace

    7. Check on Calculate by Program.

    8. Click on Apply button and Close button.

    2

    3

    4

    4

    midasGen Tutor ial Eur ocode3 - Design of M ul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    33/45

    midas Gen Tutor ial Eur ocode 3 Design of Mul ti Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.33

    Step 7: Assign/Confirm Serviceability Load Combination Type

    1. Design > General Design Parameter > Serviceabil ity Load Combination Type

    2. Click on Close button.

    2

    midasGen Tutor ial Eur ocode3 - Design of M ul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    34/45

    midas Gen Tutor ial Eur ocode 3 Design of Mul ti Story Steel Bu il ding

    MIDAS Information Technology Co., Ltd.34

    Step 8: Enter Serviceability Parameters

    1. View > Select > I dentity

    2. Select Type: Element Type

    3. Select BEAM.

    4. Click on Add button and Close button.

    5. Design > Steel Design Parameter > Serviceabili ty Parameters

    6. Option: Add/Replace

    7. Selection Type: By Selection

    8. Deflection Control For Beams: L / 250

    9. Deflection Control For Columns: h / 300

    10. Deflection Amplification Factor: 1

    11.Click on Apply button and Close button.

    11

    10

    9

    2

    3

    4

    5

    6

    7

    8

    I f the elements l ocal x -ax is i s paral l el to the global Z-ax is, t he

    element is considered as a column. If theelements local x-axis is

    parallel to global X-Y plane, theelement is considered asbeam. All

    other elements except for columns and beams are considered to be

    braces.

    midasGen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    35/45

    dasGe uto a g y g

    MIDAS Information Technology Co., Ltd.35

    Step 9: Steel Code Checking (1)

    1. Design > Steel Code Check

    2. Click on button.

    3. Select SECT 5 & SECT 6.

    4. Click on Graphic button.

    2

    4

    3

    Ul timate Limit State Check Results

    COM: Criti cal ratio by axial f orce and bending moment (Yielding & Buckli ng)

    SHR: Criti cal ratio by shear force (Yielding & Buckli ng)

    Servi ceabil ity L imi t State Check Resul ts

    Beam: Vertical deflection

    Column: H orizontal deflection

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    36/45

    g y g

    MIDAS Information Technology Co., Ltd.36

    Step 10: Steel Code Checking (2)

    Ul timate L imit State Check Resul t is NG.

    Servi ceabil ity Limit State Check Result is OK.

    1. Click on Close button.

    1

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    37/45

    g y g

    MIDAS Information Technology Co., Ltd.37

    Step 11: Change the NG Sections (1)

    1. Click on button.

    2. Click on Change button.

    3. Limit Combined Ratio from 0.8 to 1.

    4. Click on Search Satisfied Section.

    5. Select HEB340.

    6. Click on Change button.

    3

    2

    4

    5

    61

    Changecommand will veri fy the strength for the user-selected section and save

    the design results until re-analysis is performed.

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    38/45

    MIDAS Information Technology Co., Ltd.38

    Step 11: Change the NG Sections (2)

    1. Select Property No. 6.

    2. Limit Combined Ratio from 0.8 to 1.3. Click on Search Satisfied Section.

    4. Select HEA280.

    5. Click on Change & Close button.

    2 3

    4

    5

    Updatecommand will allow theuser to update the section and re-analyze.

    1

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    39/45

    MIDAS Information Technology Co., Ltd.39

    Step 11: Change the NG Sections (3)

    1. Select SECT 6.

    2. Click on Graphic button.

    1

    2

    Only the section for design review has been changed.

    The section in themodel hasnot been changed asseen

    in theWorks Tree.

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    40/45

    MIDAS Information Technology Co., Ltd.40

    Step 11: Change the NG Sections (4)

    1. Click on Close button.

    1

    Ul timate Limit State Check Resul t is OK.

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    41/45

    Properties BeforeChangerepresents the sections used in the analysis.

    Properties AfterChangerepresents the sections used in the Design Change.

    MIDAS Information Technology Co., Ltd.41

    Step 12: Update the Design Sections (1)

    1. Click on Update button.

    2. Click on Select All Changed Properties button.

    3. Click on

  • 5/22/2018 Steel Design EC3

    42/45

    MIDAS Information Technology Co., Ltd.42

    Step 12: Update the Design Sections (2)

    1. Click on Re-analysis button.

    2. Click on Re-check button.

    1

    2

    1. Re-analyze the model.

    2. Re-do the steel code check.

    Fi nal design results

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    43/45

    MIDAS Information Technology Co., Ltd.43

    Step 13: Change the Section with Low Ratio (1)

    1. Click on View Result Ratio button.

    2. Select ID: 2.

    3. Ratio Limit: From 0, To 0.5

    4. Click on Show Graph of Result Ratio

    button.

    5. Click on Select Elements button.

    6. Click on Close button.

    2

    4

    3

    5

    6

    1

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    44/45

    MIDAS Information Technology Co., Ltd.44

    Step 13: Change the Section with Low Ratio (2)

    1. Drag & Drop 1: IPE500 into the Model View.

    2. Click on Yes button.

    2

    1

    Among the elements assigned with IPE600, the elements

    whose combined resistance ratio is less than 0.5 are

    changed into a smaller section I PE500.

    midas Gen Tutor ial Eur ocode 3 - Design of Mul ti-Story Steel Bu il ding

  • 5/22/2018 Steel Design EC3

    45/45

    Step 13: Change the Section with Low Ratio (3)

    1. Analysis > Perform Analysis

    2. Design > Steel Code Check

    3. Click on View Result Ratio button.

    4. Select ID: 2.

    5. Ratio Limit: From 0, To 1

    6. Click on Show Graph of Result Ratio button.

    7. Click on Close button.

    3

    4

    5

    6

    Combined resistance ratiosof Section ID. 2 areall above 0.5.