2
2:178 Steam Traps Float & Thermostatic 2:178 Max. Operating Pressure 450 psig (31 barg) Max. Operating Temperature Optional Bimetal 650˚F (343°C) at 450 psig (31 barg) Pressure Shell Design Conditions PMA 450 psig/up to 650˚F 31 barg/up to 343˚C Max. allowable pressure 425 psig/700˚F 29 barg/371˚C 375 psig/750˚F 26barg/400˚C TMA Max. allowable temperature 750˚F/0-375 psig 400˚C/0-26 barg The trap contains a float valve mechanism which modulates to discharge condensate continuously at steam temperature, while non-condensible gases are released by a separate internal thermostatic air vent. In the interests of development and improvement of the product, we reserve the right to change the specification. Model FT450 PMO 450 psig Sizes 3" 4" Connections NPT, SW, Flanged Flanged Construction Carbon Steel Body Stainless Steel Internals No. Part Material 1 Body Cast Carbon Steel ASTM A216 WCB 2 Cover Cast Carbon Steel ASTM A216 WCB 3 Cover Gasket Graphite with SS insert 4 Cover Bolts Alloy Steel ASTM A193 GR B7 5 Lockwashers Steel 6 Main Valve Assembly Stainless Steel Valve Mech. Gasket Graphite Valve Mech. Screws Stainless Steel 7 Float Stainless Steel ASTM A240 Type 304 8 Cover Plug (3/4" NPT) Steel Drain Plug (3/4" NPT) Steel 9 Companion Flange Forged Steel 10 Flange Bolts Alloy Steel ASTM A193 GR B7 11 Air Vent Assembly Stainless Steel Air Vent Head Stailess Steel Air Vent Seal Stainless Steel 11A Air Vent Stainless Steel & Bimetal RAU Type RR 12 Air Vent Pipe Stainless Steel Construction Materials Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. Typical Applications • Reboilers, heat exchangers and other large process equipment • Large absorption chillers • In combination with the Spirax Sarco 4" Pressure Powered Pump TI-2-3041-US 2.14 Capacities 11 2 12 4 5 3 1 9 10 7 8 6 * * Limiting Operating Conditions 1,000,000 800,000 700,000 600,000 500,000 400,000 300,000 200,000 150,000 100,000 80,000 70,000 60,000 50,000 40,000 30,000 1 1.5 2 3 4 5 7 10 15 20 30 40 50 70 100 150 200 300 400 .1 .15 .2 .3 .4 .5 .7 1 1.5 2 3 4 5 7 10 15 20 32 400,000 300,000 200,000 150,000 100,000 70,000 50,000 40,000 30,000 20,000 15,000 Differential Pressure bar Differential Pressure psi Condensate lb/hr Condensate kg/hr * In this region the trap capacity may exceed the flow capacity of the connection piping. Cold Hot 3" NPT/SW Cast Steel Float & Thermostatic Steam Trap 3'' and 4'' FT450 750˚F (400˚C) at operating pressures below 375 psig (26 barg) The product must not be used in this region. The product must not be used in this region as damage to internals may occur. Pressure (psig) Pressure bar g Temperature °C Temperature °F 400 300 200 100 0 752 572 392 212 32 0 145 10 435 290 464 580 725 20 30 40 32 50 0 Steam saturation curve Thermostatic air vent Operating Range Standards This product fully complies with the requirements of the European Pressure Equipment Directive 97/23/EC, and carries the CE mark when so required. Certification This product is available with certification to EN 10204 3.1. Designed in accordance with ASME VIII Dir 1. Note: All certification/inspection requirements must be stated at the time of order placement.

Steam Trap 01C51A

Embed Size (px)

DESCRIPTION

nb

Citation preview

  • Stea

    m T

    raps

    Floa

    t &Th

    erm

    osta

    tic

    2:178

    Stea

    m T

    raps

    Floa

    t &Th

    erm

    osta

    tic

    2:178

    Max. Operating Pressure 450 psig (31 barg) Max. Operating Temperature Optional Bimetal 650F (343C) at 450 psig (31 barg)

    Pressure Shell Design Conditions PMA 450 psig/up to 650F 31 barg/up to 343CMax. allowable pressure 425 psig/700F 29 barg/371C 375 psig/750F 26barg/400CTMA Max. allowable temperature 750F/0-375 psig 400C/0-26 barg

    The trap contains a float valve mechanism which modulates to discharge condensate continuously at steam temperature, while non-condensible gases are released by a separate internal thermostatic air vent.

    In the interests of development and improvement of the product, we reserve the right to change the specification.

    Model FT450

    PMO 450 psig Sizes 3" 4"

    Connections NPT, SW, Flanged Flanged Construction Carbon Steel Body Stainless Steel Internals

    No. Part Material 1 Body Cast Carbon Steel ASTM A216 WCB 2 Cover Cast Carbon Steel ASTM A216 WCB 3 Cover Gasket Graphite with SS insert 4 Cover Bolts Alloy Steel ASTM A193 GR B7 5 Lockwashers Steel 6 Main Valve Assembly Stainless Steel Valve Mech. Gasket Graphite Valve Mech. Screws Stainless Steel 7 Float Stainless Steel ASTM A240 Type 304 8 Cover Plug (3/4" NPT) Steel Drain Plug (3/4" NPT) Steel 9 Companion Flange Forged Steel 10 Flange Bolts Alloy Steel ASTM A193 GR B7 11 Air Vent Assembly Stainless Steel Air Vent Head Stailess Steel Air Vent Seal Stainless Steel 11A Air Vent Stainless Steel & Bimetal RAU Type RR 12 Air Vent Pipe Stainless Steel

    Construction Materials

    Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only.

    Typical Applications Reboilers, heat exchangers and other large process equipment Large absorption chillers In combination with the Spirax Sarco 4" Pressure Powered Pump

    TI-2-3041-US 2.14

    Capacities

    11212453

    1

    910

    78

    6

    **

    Limiting Operating Conditions

    1,000,000800,000700,000600,000

    500,000

    400,000

    300,000

    200,000

    150,000

    100,000

    80,00070,00060,00050,000

    40,000

    30,000

    1 1.5 2 3 4 5 7 10 15 20 30 40 50 70 100 150 200 300 400

    .1 .15 .2 .3 .4 .5 .7 1 1.5 2 3 4 5 7 10 15 20 32

    400,000

    300,000

    200,000

    150,000

    100,000

    70,000

    50,000

    40,000

    30,000

    20,000

    15,000

    Differential Pressure bar

    Differential Pressure psi

    Con

    den

    sate

    lb/h

    r

    Con

    den

    sate

    kg/

    hr

    * In this region the trap capacity may exceed the flow capacity of the connection piping.

    Cold

    Hot

    3" NPT/SW

    Cast Steel Float & Thermostatic Steam Trap 3'' and 4'' FT450

    750F (400C) at operating pressures below 375 psig (26 barg)

    The product must not be used in this region.

    The product must not be used in this regionas damage to internals may occur.

    Pressure (psig)

    Pressure bar g

    Tem

    pera

    ture

    C

    Tem

    pera

    ture

    F400

    300200

    100

    0

    752

    572

    392

    212

    320

    145

    10

    435290 464 580 725

    20 30 4032 50

    0

    Steam saturation curve

    The

    rmo

    stat

    ic a

    ir v

    ent

    Op

    erat

    ing

    Ran

    ge

    StandardsThis product fully complies with the requirements of the European Pressure Equipment Directive 97/23/EC, and carries the CE mark when so required.CertificationThis product is available with certification to EN 10204 3.1. Designed in accordance with ASME VIII Dir 1. Note: All certification/inspection requirements must be stated at the time of order placement.

  • Stea

    m T

    raps

    Floa

    t &Th

    erm

    osta

    tic

    2:179

    Stea

    m T

    raps

    Floa

    t &Th

    erm

    osta

    tic

    2:179

    Cast Steel Float & Thermostatic Steam Trap3'' and 4'' FT450

    Spirax Sarco, Inc., 1150 Northpoint Blvd, Blythewood, SC 29016 Telephone: (803) 714-2000 FAX (803) 714-2222

    S

    pira

    x S

    arco

    , In

    c. 2

    014

    TI-2-3041-US 2.14

    Sample SpecificationSteam traps shall be of the mechanical ball float type having cast steel bodies with stainless steel internal parts. The piping connections shall be horizontal in-line, and the body shall incorporate mounting legs with drilled pads. The traps shall have an integral thermostatic air vent. The trap body shall be horizontally split and all internal parts shall be completely serviceable without disturbing the inlet and outlet piping.

    InstallationThe trap should be located below and close to the equipment drain point. A pipe-line strainer should be installed ahead of the trap, and full port isolating valves should be placed to permit servicing. The mounting legs should be bolted to a firm horizontal support. Access above the trap must be provided for servicing.Complete installation instructions are given in IMI 2.3041.

    MaintenanceThis product can be maintained without disturbing the piping connections. Complete isolation from both supply and return line is required before any servic-ing is performed.

    The trap should be disassembled periodically for inspection and cleaning of the valve mechanism and air vent.

    Complete installation and maintenance instructions are given in IMI 2.3041, which accompanies the product.

    D

    F

    E

    B

    P

    3/4" NPT

    7.56192

    12.0305

    3/4" NPT

    6.75171

    3" NPT, SW27.75 705

    .625Mounting Holes

    11.529217.5444

    32.0813

    with

    dra

    wal

    23.7602

    16.0406

    8.0203

    Spare Parts

    Dimensions (nominal)

    Weight 485 lb (220 kg)3" ANSI 150 or 300 RF,4" ANSI 150 or 300 RF

    39.0 990

    Valve Mechanism Kit D, E, F

    Gasket Kit (pkt of 3 each) B, K

    Air Vent Kit Standard N, J, M, H, L, K Air Vent Kit Optional K, H

    Float Kit P

    StandardAir Vent Assembly

    Optional BimetalAir Vent Assembly

    K N J M H LK H