Status of DT Local Trigger Commissioning
C. Battilana, F.R. Cavallo, S. Marcellini
•YB0, YB+1 and YB+2 fully analyzed and already updated on the commissioning web page
•New computation of trigger efficiency to avoid bias due to geometrical effects
•Discussion and classification of problems
CMS week Dec. 07 1
Local Trigger Efficiency Definition
We want to compute efficiency in MB2:
We require a reconstructed track segment In MB2 with > 6 hits in ± 40 degrees around the perpendicular direction.
We also require another trigger and another track segment in any another barrel station of the same sector
If these conditions occur, we check if there is a trigger at any BX in MB2.
This definition avoid biases which happenin cases when only one station is crossed,for which trigger effic. is by definition 100 %CMS week Dec. 07 2
CMS week Dec. 07 3
Technical trigger: a trigger in at least one station, with a “almost” HanyTheta configuration. “Almost” means that the trigger occurs with HanyTheta, but also Low Triggers are released if the chamber is not triggering
Overview of the Results
S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12
YB0 314 12611 269 17319 12819 13475 349 21643 480 18947 166 15361
YB+1 17562 17588 17613 17846 17613 17596 16517 17501 17547 14668 15134 14345
YB+2 18311 22341 24173 23033 18024 24173 23282 23033 18024 25393 22341 18311
Green OK
Red Low efficiency in all stations.
Purple Low efficiency only in MB4
Black OK but maybe a specific hardware problem
Light blue Other different inefficiency problems
Bold italic underlined (any color) changed during the test
CMS week Dec. 07 4
Case: OKPo
sitio
n
Angle
Efficiency Occupancy
MB1
MB2
MB3
MB4
CMS week Dec. 07 5
Case: OK
Phi effic. vs angle Theta effic. vs angle
HH+HL Phi effic. vs angle H-Theta effic. vs angle
CMS week Dec. 07 6
MB4 has only correlatedtriggers
Case: OK (this is a Sector 4, where MB4 is big and splitted in two parts)
Phi effic. vs position Theta effic. vs position
HH+HL Phi effic. vs position H-Theta effic. vs position
CMS week Dec. 07 7
Dead cell
Case: OKBX
Trigger quality
Phi Triggers Theta Triggers
Best Quality has most entries, and it also defines the “correct BX”
CMS week Dec. 07 8
Case: Low efficiency in all stations Po
sitio
n
Angle
Efficiency Occupancy
MB1
MB2
MB3
MB4
CMS week Dec. 07 9
Case: Low efficiency in all stations
Phi effic. vs position Theta effic. vs position
HH+HL Phi effic. vs position H-Theta effic. vs position
All efficiencies scaled by about 20 %CMS week Dec. 07 10
Case: Low efficiency in all stations BX
Trigger quality
Phi Triggers Theta Triggers
Plots look normal,except Theta triggers in MB4CMS week Dec. 07 11
Case: Low efficiency in all stations
Explanations:
Several cases of doubled events, for what concerns trigger information, as well as swapped trigger primitives between MB1-MB3 and MB2-MB4 (this explains those events with theta trigger primitives in MB4, which are actually coming from MB2.
Also events with no triggers at all, usually in bunches, related to very noisy events.
For all these events there is no matching between TDC-tracks and trigger primitives.
We checked that in runs catalogued as OK, with good efficiency, such bad events are not present, or are just very rare.
These events should not occur with the final DAQ and electronics read-out,and are peculiar of the system used for the test.
CMS week Dec. 07 12
Case: Low Efficiency Only in MB4 Po
sitio
n
Angle
Efficiency Occupancy
MB1
MB2
MB3
MB4
CMS week Dec. 07 13
Case: Low Efficiency Only in MB4
Phi effic. vs angle Theta effic. vs angle
HH+HL Phi effic. vs angle H-Theta effic. vs angle
CMS week Dec. 07 14
Case: Low Efficiency Only in MB4
Nothing strange in the trigger quality
BX
Trigger quality
Phi Triggers Theta Triggers
CMS week Dec. 07 15
Case: Low Efficiency Only in MB4
Explanations:
In run 25393, YB+2, S10, together with the MB4 inefficiency, there are frequent cases with HH quality triggers in MB4, and no TDC track in that station. It might be a sign of bad data.
In runs 269 (YB0, S3) and 349 (YB0 S7) and 18947 (YB0 S10) no strange behaviour is observed, except the MB4 inefficiency. Pierluigi and Cristina suggest it might be a wrong shift (positive instead of negative) wrongly assigned in the configurations.
CMS week Dec. 07 16
Case: OK but maybe a specific hardware problem (YB+1, Sector 2)
The Theta occupancy plot is OK
BUT
H-Theta BTIs are not releases(but L Theta trigger efficiency is 100 %)
CMS week Dec. 07 17
Case: Other different inefficiency problems (S11 YB+1)
Phi effic. vs angle Theta effic. vs angle
HH+HL Phi effic. vs angle H-Theta effic. vs angle
Only H-Theta efficiency is Low.CMS week Dec. 07 18
Case: Other different inefficiency problems (S12 YB+1)
Phi effic. vs position Theta effic. vs position
HH+HL Phi effic. vs position H-Theta effic. vs position
H-Theta effic. Low and different from station to station
HH+HL Phi efficiency is low CMS week Dec. 07 19
Case: Other different inefficiency problems (S12 YB+1)
Theta Quality peaked at Low triggerPhi Quality peaked at HL instead of HH
BX
Trigger quality
Phi Triggers Theta Triggers
CMS week Dec. 07 20
Case: Similar to YB-1, Sector 1 ?
CMS week Dec. 07 21
Some gas problem was observed in this case
Case: Similar to YB-1, Sector 1 ?
CMS week Dec. 07 22
Conclusions
CMS week Dec. 07 23
•In general the trigger performs correctly.
•Several cases of low efficiency seem related to DAQ performances and should not occur in the final system (it can be checked in GREN data)
•A small number of sector with strange behaviour, which should be checked more carefully