17
STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS Overview

STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

STATIONARY CONCRETE PUMPSSEPARATE PLACING BOOMS

O ve r v i e w

070417_RZ_Betonpumpen_GB 1 17.04.2007 22:24:37 Uhr

Page 2: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

STATIONARY CONCRETE PUMPS

06 | 07 SP 305

08 | 09 SP 500

10 | 11 SP 750

12 | 13 SP 1400

14 | 15 SP 1800

16 | 17 SP 2800

18 | 19 SP 3800

20 | 21 SP 4800

22 | 23 SP 8800

CONTENTS

070417_RZ_Betonpumpen_GB 2 17.04.2007 20:17:18 Uhr

SEPARATE PLACING BOOMS

24 | 25 SBP 28

26 | 27 SBP 30

28 | 29 SBP 35

070417_RZ_Betonpumpen_GB 3 17.04.2007 20:17:18 Uhr

Page 3: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

04 | 05

CONCRETE BATCHING PLANTS

TRUCK MIXERS

TRUCK-MOUNTED CONCRETE PUMPS

STATIONARY CONCRETE PUMPS

SEPARATE PLACING BOOMS

CONCRETE RECYCLERS

070417_RZ_Betonpumpen_GB 4 17.04.2007 19:41:51 Uhr

Wherever concrete is produced and moved is where you will find

Schwing-Stetter machinery.

With plants in Germany, Austria, USA, Brazil, Russia, China and

India as well as with more than 100 sales and service facilities,

the group of companies is always close to the customer.

Our wide range of products with something for every application

is what makes Schwing-Stetter the No. 1 system supplier for

concrete machinery worldwide.

SCHWING-STETTER MOVES CONCRETE. WORLDWIDE.

070417_RZ_Betonpumpen_GB 5 17.04.2007 19:41:54 Uhr

Page 4: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

06 | 07

Performance data is max. theoretical(Max. output and max. pressure cannot be achieved simultaneously.)

TECHNICAL DATA

SP 305

Type D-125 x 750

Performance

Output m3/h 23

Pressure bar 43

Strokes /min 40

Installed output kW 35

Weight, approx. kg 1,525

070417_RZ_Betonpumpen_GB 6 17.04.2007 19:41:54 Uhr

STATIONARY CONCRETE PUMP SP 305

070417_RZ_Betonpumpen_GB 7 17.04.2007 19:41:54 Uhr

Page 5: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

08 | 09

Performance data is max. theoretical(Max. output and max. pressure cannot be achieved simultaneously.)

TECHNICAL DATA

SP 500

Type D-150 x 1000

Performance

Output m3/h 35

Pressure bar 76

Strokes /min 32

Installed output kW 54

Weight, approx. kg 2,270

070417_RZ_Betonpumpen_GB 8 17.04.2007 19:41:54 Uhr

STATIONARY CONCRETE PUMP SP 500

070417_RZ_Betonpumpen_GB 9 17.04.2007 19:41:55 Uhr

Page 6: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

10 | 11

Performance data is max. theoretical(Max. output and max. pressure cannot be achieved simultaneously.)

TECHNICAL DATA

SP 750

Type D-180 x 1000 D-150 x 1000

Performance

Output m3/h 54 38

Pressure bar 76 76

Strokes /min 35 35

Installed output kW 75 75

Weight, approx. kg 3,340 3,160

070417_RZ_Betonpumpen_GB 10 17.04.2007 19:41:55 Uhr

STATIONARY CONCRETE PUMP SP 750

070417_RZ_Betonpumpen_GB 11 17.04.2007 19:41:55 Uhr

Page 7: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

12 | 13

S = rod sided, K = piston sided

Performance data is max. theoretical(Max. output and max. pressure cannot be achieved simultaneously.)

TECHNICAL DATA

SP 1400

Type D-180 x 1400

Performance S / K

Output m3/h 52 / 34

Pressure bar 63 / 99

Strokes /min 24 / 16

Installed output kW 75

Weight, approx. kg 3,600

070417_RZ_Betonpumpen_GB 12 17.04.2007 19:41:55 Uhr

STATIONARY CONCRETE PUMP SP 1400

070417_RZ_Betonpumpen_GB 13 17.04.2007 19:41:55 Uhr

Page 8: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

14 | 15

TECHNICAL DATA

SP 1800

Type D-200 x 1600 E-200 x 1600

Performance S / K S / K

Output m3/h 73 / 42 73 / 42

Pressure bar 60 / 108 60 / 108

Strokes /min 24 / 14 24 / 14

Installed output kW 74 / 126 75 / 90

Weight, approx. kg 4,000 4,000

S = rod sided, K = piston sided

Performance data is max. theoretical(Max. output and max. pressure cannot be achieved simultaneously.)

070417_RZ_Betonpumpen_GB 14 17.04.2007 19:41:55 Uhr

STATIONARY CONCRETE PUMP SP 1800

070417_RZ_Betonpumpen_GB 15 17.04.2007 19:41:56 Uhr

Page 9: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

16 | 17

TECHNICAL DATA

SP 2800

Type D-200 x 1600 E-200 x 1600

Performance S / K S / K

Output m3/h 101 / 58 101 / 58

Pressure bar 60 / 108 60 / 108

Strokes /min 33 / 19 33 / 19

Installed output kW 129 110 / 132

Weight, approx. kg 5,000 5,000

S = rod sided, K = piston sided

Performance data is max. theoretical(Max. output and max. pressure cannot be achieved simultaneously.)

070417_RZ_Betonpumpen_GB 16 17.04.2007 19:41:56 Uhr

STATIONARY CONCRETE PUMP SP 2800

070417_RZ_Betonpumpen_GB 17 17.04.2007 19:41:56 Uhr

Page 10: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

18 | 19

TECHNICAL DATA

SP 3800

Type D-200 x 2000 E-200 x 2000

Performance S / K S / K

Output m3/h 95 / 58 95 / 58

Pressure bar 81 / 137 81 / 137

Strokes /min 26 / 16 26 / 16

Installed output kW 190 160

Weight, approx. kg 7,000 7,000

S = rod sided, K = piston sided

Performance data is max. theoretical(Max. output and max. pressure cannot be achieved simultaneously.)

070417_RZ_Betonpumpen_GB 18 17.04.2007 19:41:56 Uhr

STATIONARY CONCRETE PUMP SP 3800

D-180 x 2000 E-180 x 2000

S / K S / K

78 / 48 78 / 48

100 / 169 100 / 169

26 / 16 26 / 16

190 160

7,000 7,000

070417_RZ_Betonpumpen_GB 19 17.04.2007 19:41:58 Uhr

Page 11: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

20 | 21

TECHNICAL DATA

SP 4800

Type D-200 x 2000 D-180 x 2000

Performance S / K S / K

Output m3/h 81 / 53 66 / 43

Pressure bar 104 / 163 156 / 243

Strokes /min 21 / 14 21 / 14

Installed output kW 330 330

Weight, approx. kg 8,000 8,000

S = rod sided, K = piston sided

Performance data is max. theoretical(Max. output and max. pressure cannot be achieved simultaneously.)

070417_RZ_Betonpumpen_GB 20 17.04.2007 19:41:59 Uhr

STATIONARY CONCRETE PUMP SP 4800

E-180 x 2000

S / K

66 / 43

156 / 243

21 / 14

200

8,000

070417_RZ_Betonpumpen_GB 21 17.04.2007 19:42:01 Uhr

Page 12: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

22 | 23

TECHNICAL DATA

SP 8800

Type D-200 x 2000 D-180 x 2000

Performance S / K S / K

Output m3/h 116 / 77 94 / 63

Pressure bar 104 / 163 156 / 243

Strokes /min 31 / 21 31 / 21

Installed output kW 440 440

Weight, approx. kg 10,000 10,000

S = rod sided, K = piston sided

Performance data is max. theoretical(Max. output and max. pressure cannot be achieved simultaneously.)

070417_RZ_Betonpumpen_GB 22 17.04.2007 19:42:02 Uhr

STATIONARY CONCRETE PUMP SP 8800

E-180 x 2000

S / K

91 / 60

156 / 243

30 / 20

2 x 200

10,000

070417_RZ_Betonpumpen_GB 23 17.04.2007 19:42:03 Uhr

Page 13: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

24 | 25

TECHNICAL DATA

Type SPB 28

Horizontal reach m 28

Number of arms 4

Pipeline dia. DN 125

End hose m 4

Weight kg 6,600

Optional split boom yes

Optional counterweight kg 6,000

max. free-standing height m 20on octo-column (w.o. c/wt)

070417_RZ_Betonpumpen_GB 24 17.04.2007 19:42:03 Uhr

End hose 4.00 m

6.35 m 7.05 m 7.05 m 7.55 m

Horizontal reach 28.00 m

SEPARATE PLACING BOOM SPB 28

070417_RZ_Betonpumpen_GB 25 17.04.2007 19:42:03 Uhr

Page 14: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

26 | 27

TECHNICAL DATA

Type SPB 30

Horizontal reach m 30

Number of arms 4

Pipeline dia. DN 125

End hose m 4

Weight kg 6,700

Optional split boom yes

Optional counterweight kg 6,000

max. free-standing height m 20on octo-column (w.o. c/wt)

070417_RZ_Betonpumpen_GB 26 17.04.2007 19:42:03 Uhr

7.50 m 7.25 m 7.21 m 8.05 m 8.19 m

3.00 m

SEPARATE PLACING BOOM SPB 30

070417_RZ_Betonpumpen_GB 27 17.04.2007 19:42:04 Uhr

Page 15: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

28 | 29

TECHNICAL DATA

Type SPB 35

Horizontal reach m 35

Number of arms 4

Pipeline dia. DN 125

End hose m 4

Weight kg 8,000

Optional split boom yes

Optional counterweight kg 6,000

max. free-standing height m 14on octo-column (w.o. c/wt)

070417_RZ_Betonpumpen_GB 28 17.04.2007 19:42:04 Uhr

8.56 m 8.37 m 8.38 m 9.33 m 9.49 m

4.28 m

SEPARATE PLACING BOOM SPB 35

070417_RZ_Betonpumpen_GB 29 17.04.2007 19:42:04 Uhr

Page 16: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

30 | 31

070417_RZ_Betonpumpen_GB 30 17.04.2007 19:42:04 Uhr070417_RZ_Betonpumpen_GB 31 17.04.2007 19:42:05 Uhr

Page 17: STATIONARY CONCRETE PUMPS SEPARATE PLACING BOOMS

SCHW

ING

GmbH

| Hee

rstr

aße

9-27

| 446

53 H

erne

| T 0

2325

987

-0 | F

023

25 7

2992

| inf

o@sc

hwin

g.de

| ww

w.s

chw

ing.

de

070417_RZ_Betonpumpen_GB 32 17.04.2007 19:42:05 Uhr