Upload
peerless-lighting-for-people
View
219
Download
1
Embed Size (px)
DESCRIPTION
Everyone Deserves Great Lighting Whether in classrooms, cafeterias, labs, libraries and lecture halls. Or offices, boardrooms and conference centers. Or stores, lobbies and showrooms. Everyone who spends the majority of their day inside deserves great lighting.What is great lighting? It’s lighting with all the essentials: • Modern Design • Efficient Performance • Comfortable Illumination • Energy-Saving Controls Introducing Staple. All the fundamentals of great lighting accessible to all. Watch video and learn more at http://www.PeerlessLighting.com/Staple
Citation preview
Everyone Deserves Great Lighting
2
Everyone inSchools
EveryoneEverywhere
Everyone inOffices
EveryoneLike You
Shoppers
Merchants
Artists
Prima Ballerinas
Patients
Scientists
Civil Servants
Dentists
Contractors
Architects
Lighting Designers
Building Owners
Interior Designers
Engineers
Facility Managers
Electricians
Executives
Employees
Managers
Sales Teams
Captains of Industry
Receptionists
Desk Jockeys
Bean Counters
Students
Teachers
Librarians
Jocks and Geeks
Degree Seekers
Homecoming Queens
Administrators
Janitors
3
Great Lighting for All Walks of Life
Whether in classrooms, cafeterias, labs, libraries and lecture halls. Or offices, boardrooms and conference centers. Or stores, lobbies and showrooms. Everyone who spends the majority of their day inside deserves great lighting.
What is great lighting? It’s lighting with all the essentials:
Introducing Staple. All the fundamentals of great lighting accessible to all.
Even that dorky IT guy down the hall.
Watch Video and Learn More at PeerlessLighting.com/Staple
Modern Design
Comfortable Illumination
Efficient Performance
Energy-Saving Controls
4
5
Everyone Deserves...
Modern Design
Subtle contours around the perimeter of the rectilinear body make Staple pleasingly approachable like Ms. Peach, your high-school principal. Its neutral (think Switzerland) form makes it suitable for a wide-range of installations.
A soft glowing acrylic baffle or diffuse lens extends edge to edge and end to end creating seamless continuity. Gloss white paint finishes the understated yet thoroughly modern luminaire.
FE ATU RES
Luminous acrylic baffle or diffused lens shielding
Suspended model with 1, 2 or 3 lamps (T8 or T5/T5HO)
Wall-mount model with 1 or 2 lamps (T8 or T5/T5HO)
4, 8 or 12 ft. sections for individual units or continuous rows
6
7
Staple delivers on the Peerless mantra of Lighting for People® by emitting diffuse, uniform and glare-free illumination.
Optically engineered shielding and reflectors produce a quality of light that minimizes eyestrain and fatigue often experienced by those who spend significant time reading, writing, programming and googling “sick day excuses.”
With most lamping options meeting IES Recommended Practice for open offices (RP-1) and Collaborative for High Performance Schools (CHPS) guidelines, Staple produces exactly the kind of illumination that promotes workplace productivity and improves classroom learning.
Everyone Deserves...
Comfortable Illumination
SPM4 2-LAMP T8 90.9% efficiency9092 delivered lumens
67.4% up / 32.6% down
SPM9 2-LAMP T8 91.7% efficiency9170 delivered lumens
69.2% up / 30.8% down
90 270
500
1000
90 270
500
1000
90%+Everyone Deserves...
Efficient Performance
To reduce electricity use, meet building power density requirements and impress even the most miserly of energy misers, Staple directs lumens exactly where they’re needed.
With a standard 65% indirect, 35% direct distribution, Staple delivers the needed lumens on the work plane while effectively illuminating
the whole space with natural, even lighting. And it achieves this balancing act with minimal lumen loss; Staple is more than 90% efficient.
For applications where ceiling reflectivity is less than optimal, Staple may be specified with optional variable distribution reflectors to redirect more light downward.
8
Cl A SSRooM APPlIC ATIonS
lamping
lamping
ceilin
g height
2.5‘ avg
. work
plane
illu
minancenorth
wall
white
board ill
uminance
overa
ll susp
ension
power densit
y
(w/s
f)north w
all unifo
rmity
(max
:min)
spac
ing
(2) T8 10’ 24” 14’ 43fc / 42fc 19fc / 21fc 1.4:1 / 1.4:1 0.80Collaborative for High Performance Schools (CHPS) 35-50fc 15-20fc <3.0:1
30’
30’24’
14’
N
baffle / lens baffle / lens baffle / lens
NOTES: Calculation plane
3’ from walls White board plane
12’ x 4’ and 3’ off the floor
9
CALCULATION NOTES: 80/50/20 ceiling/walls/floor reflectance T8: 2850 lumen lamps, 30 input watts (1) T8,
60 input watts (2) T8 .69 LLF (light loss factor) includes:
.95 LLD (lamp lumen depreciation), .88 LDD (luminaire dirt depreciation), .88 BF (ballast factor) .94 RSDD (room surface dirt depreciation) T5: 2900 lumen lamps, 31 input watts (1) T5,
62 input watts (2) T5 .79 LLF (light loss factor) includes:
.95 LLD (lamp lumen depreciation), .88 LDD (luminaire dirt depreciation), 1.0 BF (ballast factor) .94 RSDD (room surface dirt depreciation)
PRIvATE oFFICE APPlIC ATIonS
12’
10’
8’
lampingce
iling h
eightove
rall s
uspensio
n
no. of 8
ft luminair
esav
erage i
lluminance
uniform
ity
(max
:min)
power densit
y
(w/s
f)
maxim
um
illuminance
baffle / lens baffle / lensbaffle / lens
(2) T8 10’ 18” 1 29fc / 28fc 42fc / 40fc 2.1:1 / 2.0:1 1.0
(2) T5 10’ 18” 1 32fc / 31fc 46fc / 44fc 2.1:1 / 2.0:1 1.03
2.5’ work plane
oPE n oFFICE APPlIC ATIonS
lampingce
iling h
eightove
rall s
uspensio
n
spac
ing (S)
number of 3
2’ rows
ceilin
g unifo
rmity
(max
:min)
power densit
y
(w/s
f)2.5’ work
plane
av
g. illuminance
60’S
40’32’ (1) T8 10’ 21” 10’ 6 31fc / 31fc 4.3:1 / 4.5:1 0.60
(1) T5 10’ 21” 10’ 6 37fc / 36fc 3.9:1 / 4.4:1 0.62
IES Recommended Practice-1 >30fc <8.0:1
(2) T8 10’ 24” 14’ 4 44fc / 43fc 8.1:1 / 8.9:1 0.80
(2) T5 10’ 24” 14’ 4 49fc / 49fc 7.4:1 / 7.8:1 0.83
IES Recommended Practice-1 >30fc <12.0:1
baffle / lens baffle / lensNOTES: Furniture and
partitions not considered in calculations
9
10
11
Everyone Deserves...
Energy-Saving Controls
When specified with an optional, integrated nLight® Micro Sensor, Staple becomes an intelligent Mr. Smarty Pants luminaire that provides:
Daylight dimming
Occupancy detection — dual technology passive infrared and Microphonics™
360° coverage of up to 12’ depending on mounting height
Remote or on-luminaire push-button programming
For greater row, room, building or campus control, Staple can be specified as an nLight-enabled luminaire for easy, Cat-5e “plug-and-play” connectivity with nLight control and sensor systems.
Learn more about the nLight Micro Sensor at PeerlessLighting.com/nLight-Sensor-Page
Created specifically with schools in mind, Staple can also be paired with either an nClass or Academy Pack pre-configured classroom controls package.
Learn more about these classroom solutions at PeerlessLighting.com/Classroom_Controls
TM®
ConstructionNominal 8 1⁄2” x 2 3⁄8” rectangular housing is formed from cold-rolled steel. Die-cast aluminum end caps are mechanically attached with no exposed fasteners.
ReflectorsFormed, pre-finished white reflector standard.
ShieldingSPM4: Injection molded acrylic baffle (opal diffuser optional). SPM9: Acrylic lens.
FinishWhite gloss powder paint comes standard. Custom colors available, consult factory.
ElectricalSpecify 120V, 277V or 347V. Pre-wired with 16AWG fixture wires. For special circuiting or wire gauge, consult factory. Plug-in electrical connectors included. UL and C-UL listed.
Luminaire Length4’, 8’ and 12’ lengths in a single section for nominal suspension spacing of 4’, 8’ and 12’. For total luminaire length, add 1 1⁄8” for each end cap. Using internal joiners, 4’, 8’ and 12’ sections can be joined to form longer length luminaires.
Installation Features Y-hangers with adjustable cables come standard to simplify luminaire leveling across the width and length. Individual 4’, 8’ and 12’ luminaires can be ordered with end caps and power cords pre-installed and hanging hardware included in the luminaire packaging to reduce overall installation time (option IND).
Packaging Recycled cardboard box, folded cardboard cradles and kraft tape. Biodegradable protective luminaire bag.
12
13
SPM4 Baffle (1, 2, 3) T5, T5HO, T8
SPM9 Lens (1, 2, 3) T5, T5HO, T8
Example: SPM4 2 54T5HO WHR 40FT R12 277 GEB10 DCT LP835 F1/18 C032
2 3⁄8” 2 3⁄8”
8 1⁄2” 8 1⁄2”
Emergency Type* Switching Lamp Color Mounting Type / Overall Suspension*
Finish Options
(Blank) NoneEC Emergency
circuitEL Emergency
battery pack (Not available in 347V)
EN Emergency battery pack w/night light circuit (Not available in 347V)
*EL and EC are installed in last 4’ of luminaire sections. Separate feed required unless ELS or ELS2 is specified.
SCT Single circuit
DCT Dual circuit
L/LP No lampL/LPE No lamp. Wired for energy saving T8
lamps.LP830 3000K 80+ CRILP835 3500K 80+ CRILP841 4100K 80+ CRI
Available with 28T5 only:LP830P 3000K 80+ CRI PremierLP835P 3500K 80+ CRI PremierLP841P 4100K 80+ CRI
Premier
Reference Lamp Chart on website or consult factory for other options.
F1/ T-bar ceiling (universal mounting bracket)
F1A/ T-bar ceiling (UMB with integrated J-box)
F2/ Hard ceiling (horizontal J-box)
F4A/ IDS clip 15⁄16” teeF4B/ IDS clip 9⁄16” teeF4C/ IDS clip screw slot
18 18”24 24”48 48”72 72”96 96”XX XX”
Overall suspension is measured from ceiling to bottom of luminaire.
*Adjustable cable gripper comes standard
C032 White white (high gloss)
C099 Custom finish
CP Chicago plenum (available with F1A only)DL Damp location labelDU Dust cover (not available with 3-lamp T5HO cross section)ELH Emergency through wiring w/separate feedELS Emergency through wiring w/single feed, shared neutralELS2 Emergency through wiring w/single feed, separate neutralsGLR Fusing (fast blow)GMF Fusing (slow blow)IND Individual luminaire (factory installed end caps
and power cord, hanging hardware in box)MCS Matching feed canopy at supportN100 nLight-Enabled (network ready with RJ45 connector on luminaire
and 10’ of Cat-5e) NYC New York City codeSLP Sloped ceiling (for 10-45°, must be specified along with F2, ACG
and OJB options)XXXX Integrated sensor; see spec sheet to choose options and obtain code
STAPlE oRDE RInG In FoR M ATIon
Luminaire # of Lamps in Cross Section
Lamp Type Distribution (nominal)
Reflector Shielding (SPM4 only)
Luminaire Row Length
Maximum Section Length
Voltage Ballast Type # of Emergency Modules
SPM4 BaffleSPM9 Lens
123
28T5 28W T554T5HO 54W T5HO32 32W T8
(Blank) 65% up, 35% down standard
40/60* 40% up, 60% down
20/80* 20% up, 80% down
0/100* 100% downCLI Center lamp
isolator (Available with 3-lamp cross section only)
*Nominal distribution, refer to photometric test for exact distribution.
WHR White reflector (Standard)
(Blank) NoneOPD Opal
diffuser
X FT4’ increments
R4 4’ section(s)R8 8’ section(s)R12 12’ section(s)
120277347 (Not available with 28T5 lamps)
GEB10 <10% THD Electronic
OS5C* Osram Line or 0-10V (T8)
ADEZ* Advance Mark 10 dim (T8, T5HO)
ADZT* Advance Mark 7 0-10V dim
DMHL3D* Lutron Hi-Lume dim
OSDIM* Osram 0-10V dim (T5HO)
*Not available in 347V.Reference Ballast Wizard on website or consult factory for other options.
(Blank) None1SE 1 section2SE 2 sectionsXSE X sections
ConstructionNominal 8 1⁄2” x 2 3⁄8” rectangular housing is formed from cold-rolled steel. Die-cast aluminum end caps are mechanically attached with no exposed fasteners.
ReflectorsFormed, pre-finished white reflector standard.
ShieldingSPW4: Injection molded acrylic baffle (opal diffuser optional). SPW9: Acrylic lens.
FinishWhite gloss powder paint comes standard. Custom colors available, consult factory.
ElectricalSpecify 120V, 277V or 347V. Pre-wired with 16AWG fixture wires. For special circuiting or wire gauge, consult factory. Plug-in electrical connectors included. UL and C-UL listed.
Luminaire Length4’, 8’ and 12’ lengths in a single section. For total luminaire length, add 1 1⁄8” for each end cap. Using internal joiners, 4’, 8’ and 12’ sections can be joined to form longer length luminaires.
Installation FeatureIndividual 4’, 8’ and 12’ luminaires can be ordered with end caps pre-installed and wall-mount hardware included in the luminaire packaging to reduce overall installation time (option IND).
Packaging Recycled cardboard box, folded cardboard cradles and kraft tape. Biodegradable protective luminaire bag.
14
15
SPW4 Baffle (1, 2) T5, T5HO, T8
SPW9 Lens (1, 2) T5, T5HO, T8
Example: SPW9 1 28T5 WHR 40FT R12 120 GEB10 1SE EC SCT L/LP C032 DL
Luminaire # of Lamps in Cross Section
Lamp Type Reflector Shielding (SPM4 only)
Luminaire Row Length
Maximum Section Length
Voltage Ballast Type # of Emergency Modules
SPW4 BaffleSPW9 Lens
12
28T5 28W T554T5HO 54W T5HO32 32W T8
WHR White reflector (Standard)
(Blank) NoneOPD Opal
diffuser
X FT4’ increments
R4 4’ section(s)R8 8’ section(s)R12 12’ section(s)
120277347
GEB10 <10% THD ElectronicOS5C* Osram Line or 0-10V (T8)ADEZ* Advance Mark 10 dim (T8,
T5HO)ADZT* Advance Mark 7 0-10V dimDMHL3D* Lutron Hi-Lume dimOSDIM* Osram 0-10V dim (T5HO)
*Not available in 347V.Reference Ballast Wizard on website or consult factory for other options.
(Blank) None1SE 1 section2SE 2 sectionsXSE X sections
2 3⁄8” 2 3⁄8”
8 1⁄2”1”
Emergency Type* Switching Lamp Color Finish Options
(Blank) NoneEC Emergency circuitEL Emergency
battery pack (Not available in 347V)
EN Emergency battery pack w/night light circuit (Not available in 347V)
*EL and EC are installed in last 4’ of luminaire sections. Separate feed required unless ELS or ELS2 is specified
SCT Single circuitDCT Dual circuit
L/LP No lampL/LPE No lamp. Wired for energy saving
T8 lamps.LP830 3000K 80+ CRILP835 3500K 80+ CRILP841 4100K 80+ CRI
Available with 28T5 only:LP830P 3000K 80+ CRI PremierLP835P 3500K 80+ CRI PremierLP841P 4100K 80+ CRI Premier
Reference Lamp Chart on website or consult factory for other options.
C032 White white (high gloss)C099 Custom finish
DL Damp location labelDU Dust coverELH Emergency through wiring w/separate feedELS Emergency through wiring w/single feed, shared neutralELS2 Emergency through wiring w/single feed, separate neutralsGLR Fusing (fast blow)GMF Fusing (slow blow)IND Individual luminaire (factory installed end caps and
hardware in the box)N100 nLight-Enabled (network ready with 10’ of Cat-5e)NYC New York City code
STAPlE WAll oRDE RInG In FoR M ATIon
8 1⁄2”1”SPW4 2 T8
SPW9 2 T8
SPW4 2 T8
SPW9 2 T8
2246 5th StreetBerkeley, CA 94710
510.845.2760
PeerlessLighting.com
© 2012 Acuity Brands Lighting, Inc. All rights reserved. “Peerless” and “nLight” are registered trademarks. Products in this brochure may be covered by one or more U.S. Patents and Patents Pending.