157
Republic of the Philippines DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS OFFICE OF THE SECRETARY 1. 7 MAY201i' Manila t9?7. /,3 A t#lAJ"'" dlt'" _ / P_ U; 1" DEPARTMENT ORDER ) ) ) ) 96 NO. _ Series of 201~ ll't'.II./~ SUBJECT: Standardized Pay Items of Works for Civil Works Construction for Infrastructure Projects. To ensure uniformity in the application/adoption of the Pay Items of Work involved in the preparation of the Design Plans and Quantities, Programs of Works (POW) and Approved Budget for the Contract (ABC) for Infrastructure Projects nationwide, a Standard Pay Item List is hereby prescribed (Annex "A") for various work pay items based on the DPWH Standard Specifications for Highways, Bridges and Airports (Volume II) and Buildings & Flood Control (Volume III), to include pay items subscript based on different dimensions/sizes, classifications, types and unit of measures for an item. This Standard Pay Item List incorporates some pay items not yet included in the Blue Book but are deemed necessary in the actual project implementation. Henceforth, all implementing offices of the Department are hereby directed to adopt strictly the Standardized Pay Items of Work in the preparation of the Design Plans and Quantities, Programs of Works (POW) and Approved Budget for the Contract (ABC) for all infrastructure projects for CY 2016 Program wherein said Standard Pay Items are the basis in the project monitoring under the Project Contract Management Application (PCMA), with the following considerations: a. For projects already bid out/awarded/contracted, change of pay items number/description/unit of measure to conform with the standard pay items shall be effected with the approval of the Head of Implementing Office (10); b. For projects with already approved Plans, POW & ABC, change of pay items number/description/unit of measure to conform with the standard pay items shall be effected with the approval of the Head of Implementing Office, prior to the bidding; c. For items of work not yet included in the Standard Pay Item List, the Head of 10 shall seek first the approval of the Bureau of Research and Standards (BRS), prior to its adoption. This Order take,s effect immediately. Department of Public Works and Highways Office of the Secretary III 11111 11111111111111111111111111111 WIN6W01930 5.2 WROj AMD

Standardized Pay Items of Works for Civil Works Construction for

Embed Size (px)

Citation preview

Page 1: Standardized Pay Items of Works for Civil Works Construction for

Republic of the PhilippinesDEPARTMENT OF PUBLIC WORKS AND HIGHWAYS

OFFICE OF THE SECRETARY1. 7 MAY201i' Manila

t9?7. /,3 A t#lAJ"'"

dlt'" _ / P_U;1"

DEPARTMENT ORDER ))))96NO. _

Series of 201~ ll't'.II./~

SUBJECT: Standardized Pay Items of Works forCivil Works Construction forInfrastructure Projects.

To ensure uniformity in the application/adoption of the Pay Items of Work involved in thepreparation of the Design Plans and Quantities, Programs of Works (POW) and ApprovedBudget for the Contract (ABC) for Infrastructure Projects nationwide, a Standard Pay ItemList is hereby prescribed (Annex "A") for various work pay items based on the DPWHStandard Specifications for Highways, Bridges and Airports (Volume II) and Buildings &Flood Control (Volume III), to include pay items subscript based on differentdimensions/sizes, classifications, types and unit of measures for an item. This Standard PayItem List incorporates some pay items not yet included in the Blue Book but are deemednecessary in the actual project implementation.

Henceforth, all implementing offices of the Department are hereby directed to adopt strictlythe Standardized Pay Items of Work in the preparation of the Design Plans and Quantities,Programs of Works (POW) and Approved Budget for the Contract (ABC) for all infrastructureprojects for CY 2016 Program wherein said Standard Pay Items are the basis in the projectmonitoring under the Project Contract Management Application (PCMA), with the followingconsiderations:

a. For projects already bid out/awarded/contracted, change of pay itemsnumber/description/unit of measure to conform with the standard pay items shall beeffected with the approval of the Head of Implementing Office (10);

b. For projects with already approved Plans, POW & ABC, change of pay itemsnumber/description/unit of measure to conform with the standard pay items shall beeffected with the approval of the Head of Implementing Office, prior to the bidding;

c. For items of work not yet included in the Standard Pay Item List, the Head of 10shall seek first the approval of the Bureau of Research and Standards (BRS), prior toits adoption.

This Order take,s effect immediately.

Department of Public Works and HighwaysOffice of the Secretary

III 11111 11111111111111111111111111111WIN6W01930

5.2 WROj AMD

Page 2: Standardized Pay Items of Works for Civil Works Construction for

Department of Public Works and Highways

STANDARDIZED PAY ITEMS OF WORKFOR CONSTRUCTION OF

INFRASTRUCTURE PROJECTS(Department Order No. 96, Series of 2016)

May 2016

Page 3: Standardized Pay Items of Works for Civil Works Construction for

BLUE BOOKVOL. II

.JL

Page 4: Standardized Pay Items of Works for Civil Works Construction for

PART A - FACILITIES FOR THE ENGINEERPay Item Suffix

Description I Valid Values I Unit Of Measure(Number) (Subscri I Thickness/Sizes Class I others IA.l.l Offices and Laboratorv for the Enaineer

A.1.! (!) Construction of Combined Field Office, Laboratory and Living QuartersLump SumBuildino for the Enoineer

A.1.! (2) Construction of Combined Field Office and Laboratory Building for theLump SumEnoineer

A.1.! 3 Construction of Field Office for the Enoineer Lump SumA.1.! 4 Construction of Field Laboratorv for the Enoineer Lump SumA.1.! 5 Construction of Livina Ouarters for the Enaineer Lump Sum

A.1.! (6) Provision of Combined Field Office, Laboratory and Living Quarters BuildingMonthfor the Enoineer (Rental Basis)

A.1.! (7) Provision of Combined Field Office and Laboratory Building for the EngineerMonthRental Basis)

A.1.! (S Provison of Field Office for the Enqineer (Rental Basis) MonthA.1.! (9 Provison of Laboratorv for the Enoineer (Rental Basis) Month

A.1.!f!O Provison of Livina Ouarters for the Enaineer (Rental Basis) Month

A.1.! (11) Provision of FurnituresfFixtures, Equipment & Appliances for the Field OfficeLump Sumfor the Enoineer

A.1.! (!2) Provision of FurnituresfFixtures, Equipment & Appliances for LaboratoryLump SumBuildino for the Enoineer

A.1.! (13) Provision of FurnituresfFixtures & Appliances for the Living Quarters for theLump SumEnoineer

A.1.! (14) Provision of Laboratory Testing Equipment, Apparatus and Publications for theLump SumEnaineer

A.1.! (!5) Operation & Maintenance of Temporary Field Office, Laboratory and LivingMonthIOuarters Buildina for the Enoineer

A.1.! !6 Ooeration & Maintenance of Field Office for the Enaineer MonthA.1.! !7 Ooeration & Maintenance of Laboratorv Buildina for the Enoineer MonthA.1.! !8 Ooeration & Maintenance of Livina Ouarters for the Enaineer Month

A.l.2 Vehicles for the EnaineerA.1.iCIT Provision of 4x4 Pick UO Tvoe Service Vehicle for the Enaineer Each

A.1.2 (2) Provision of 4x4 Pick Up Type Service Vehicle for the Engineer on Bare RentalMonthBasis

A.1.2 (3) Provision of 4x2 Pick UO Type Service Vehicle for the Enoineer Each

A.1.2 (4) Provision of 4x2 Pick Up Type Service Vehicle for the Engineer on Bare RentalMonthBasis

A.1.2 (5) Operation and Maintenance of 4x4 Pick Up Type Service Vehicle for theMonthEnaineer

A.1.2 (6) Operation and Maintenance of 4x2 Pick Up Type Service Vehicle for theMonthEnaineer

A.1.2 (7) Provision of 4x4 Van Tvoe Service Vehicle (12-seater) EachA.1.irs) Provision of 4x4 Van Tvoe Service Vehicle on Rental Basis (!2 Seater) Month

A.1.2 (9) Operation and Maintenance of 4x4 Van Type Service Vehicle (!2-seater) Month

Page 1 VOL II

Page 5: Standardized Pay Items of Works for Civil Works Construction for

A.1.3 Assistance to the EngineerA.1.3 (1) Provision of Field Office Staff for the Assistance to the Enaineer MonthA.1.3 (2) Provision of Survev Eauioment for the Assistance to the Enaineer Lump SumA.1.3 (3) Provision of Survev Personnel for the Assistance to the Enaineer MonthA.1.3 (4) Provision of Laboratorv Personnel for the Assistance to the Enaineer Month

A.1.4 PhotographsA.1.4 (1) IProvision of Proaress Photoaraohs T I Month

A.1.5 Communication FacilityA.1.5 (1) IProvision of Communication Facilitv for the Enaineer I I EachA.1.5 (2) IOoeration and Maintenance of Communication Facilitv for the Enaineer I Each

PART B - OTHER GENERAL REQUIREMENTS

Pay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

B.1 Offices. Shoos Stores and Workmens Accomodation for Contractor Lumo sumB.2 Medical Room and First Aid Facilities Lumo sumB.3

B.4 (1) Construction survev and stakina KilometerB.4 2 SloDe. reference. and c1earina and arubbina stakes KilometerB.4 3 Centerline reestablishment KilometerB.4 4 Culvert survev and stakina EachB.4 5) Bridae survev and stakina Lumo sumB.4 6 Retainina wall survev and stakina Lump sumB.4 7 Grade finishina stakes KilometerB.4 8 Permanent monuments and markers EachB.4 9 Miscellaneous survey and stakina Hour

B.4 ( 10) Miscellaneous survev and stakina Lumo sumB.5 Proiect Billboard / SiQnboard EachB.6 Installation of ODA Recoanition Plate Lumo sumB.7 Occupational Safetv and Health Proaram MonthB.8 Traffic Manaaement MonthB.9 Mobilization / Demobilization Lump sum

B.10 Davworks PSB.11 Provisional Sum PSB.12 Removal and Relocation of Utilities Lumo sumB.13 Additional Geotechnical Investiaation Lumo sumB.14 Environmental ManaQement and Monitorina Month

B.15 (1) Detour/Access Road Lumo sumB.15 (2) Detour/Access Road Linear Meter

B.16 Recoanition Plate/Proiect Marker EachB.17 Temporary DiverSion ot waterway Lumo Sum

B.18(1) Craneway - Lump SumB.18(2) ~raneway Linear Meter

Page 2 VOL II

Page 6: Standardized Pay Items of Works for Civil Works Construction for

PART C - EARTHWORKITEM 100 - CLEARING AND GRUBBINGPay Item Suffix Description Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes Class Others

100 1 ClearinQ and GrubbinQ Hectare100 2 Clearina and GrubbinQ Lumo Sum100 3 a Individual Removal of Trees 150-300 mm dia. Small Each100 3 b Individual Removal of Trees 301-500 mm dia. Small Each100 3 c Individual Removal of Trees 501-750 mm dia. Small Each100 3 d Individual Removal of Trees 751-900 mm dia. Small Each100 4 Individual Removal of Trees above 900mm dia. Large Each

ITEM 101- REMOVAL OF STRUCTURES AND OBSTRUCTIONSPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

101 1 Removal of Structures and Obstruction Lumo Sum101 2 Removal of Actual Structures Obstruction Each101 3 a1 Removal of Actual Structures Obstruction 0.15 m thick PCCP Reinforced Sauare Meter101 3 a2 Removal of Actual Structures Obstruction 0.20 m thick PCCP Reinforced Sauare Meter101 3 a3 Removal of Actual Structures Obstruction 0.23 m thick PCCP Reinforced ;ouare Meter101 3 a4 Removal of Actual Structures Obstruction 0.25 m thick PCCP Reinforced iauare Meter101 3 a5 Removal of Actual Structures Obstruction 0.28 m thick PCCP Reinforced iauare Meter101 3 a6 Removal of Actual Structures Obstruction 0.30 m thick PCCP Reinforced Sauare Meter101 3 a7 Removal of Actual Structures Obstruction 0.33 m thick PCCP Reinforced Square Meter101 3 a8 Removal of Actual Structures Obstruction 0.35 m thick PCCP Reinforced Sauare Meter101 3 b1 Removal of Actual Structures Obstruction 0.15 m thick PCCP Unreinforced Square Meter101 3 b2 Removal of Actual Structures Obstruction 0.20 m thick PCCP Unreinforced Sauare Meter101 3 b3 Removal of Actual Structures Obstruction 0.23 m thick PCCP Unreinforced Sauare Meter101 3 b4 Removal of Actual Structures Obstruction 0.25 m thick PCCP Unreinforced ' quare Meter101 3 b5 Removal of Actual Structures Obstruction 0.28 m thick PCCP Unreinforced quare Meter101 3 b6 Removal of Actual Structures Obstruction 0.30 m thick PCCP Unrei nforced iauare Meter101 3 b7 Removal of Actual Structures Obstruction 0.33 m thick PCCP Unreinforced iauare Meter101 3 b8 Removal of Actual Structures Obstruction 0.35 m thick PCCP Unreinforced ;ouare Meter101 3 c1 Removal of Actual Structures Obstruction 0.05 m thick ACP Square Meter101 3 c2 Removal of Actual Structures Obstruction 0.10 m thick ACP Square Meter101 3. d Removal of Actual Structures Obstruction 0.10 m thick Sidewalk Sauare Meter101 3 e Removal of Actual Structures Obstruction . 0.10 m thick Guardrails Sauare Meter101 3 f Removal of Actual Structures Obstruction 0.10 m thick Guardrail Posts Sauare Meter101 3 q Removal of Actual Structures Obstruction 0.10 m thick Road SiQns Square Meter101 4 a Removal of Actual Structures Obstruction 610 mm dia. RCPC Linear Meter101 4 b Removal of Actual Structures Obstruction 760 mm dia. RCPC Linear Meter101 4 c Removal of Actual Structures Obstruction 910 mm dia. RCPC Linear Meter101 4 d Removal of Actual Structures Obstruction 1070 mm dia. RCPC Linear Meter101 (4) e Removal of Actual Structures Obstruction 1220 mm dia. RCPC Linear Meter

Page 3 VOL II

Page 7: Standardized Pay Items of Works for Civil Works Construction for

101 4 f Removal of Actual Structures Obstruction 1520 mm dia. RCPC Linear Meter101 4 Q Removal of Actual Structures Obstruction Curb Linear Meter101 4 h Removal of Actual Structures Obstruction Curb and Gutter Linear Meter101 5 al Removal of Pices other than Pice Culverts 50 mm dia. PVC Linear Meter101 5 a2 Removal of Pioes other than Pice Culverts 75 mm dia. PVC Linear Meter101 5 a3 Removal of Pices other than Pice Culverts 100 mm dia. PVC . Linear Meter101 5 a4 Removal of Pices other than Pice Culverts 150 mm dia. PVC Linear Meter101 5 as Removal of Pices other than Pice Culverts 200 mm dia. PVC Linear Meter101 5 a6 Removal of Pices other than Pioe Culverts 250 mm dia. PVC Linear Meter101 5 a7 Removal of Pices other than Pioe Culverts 300 mm dia. PVC Linear Meter101 5 bl Removal of Pices other than Pice Culverts 150 mm dia. Concrete Linear Meter101 5 b2 Removal of Pices other than Pice Culverts 200 mm dia. Concrete Linear Meter101 5 b3 Removal of Pices other than Pioe Culverts 250 mm dia. Concrete Linear Meter101 5 b4 Removal of Pioes other than Pioe Culverts 300 mm dia. Concrete Linear Meter101 5 b5 Removal of Pices other than Pice Culverts 350 mm dia. Concrete Linear Meter

High Density101 (5) c1 Removal of Pipes other than Pipe Culverts 50 mm dia. Polyethylene Linear Meter

HOPEHigh Density

101 (5) c2 Removal of Pipes other than Pipe Culverts 75 mm dia. Polyethylene Linear MeterHOPE

High Density101 (5) c3 Removal of Pipes other than Pipe Culverts 100 mm dia. Polyethylene Linear Meter

HOPEHigh Density

101 (5) c4 Removal of Pipes other than Pipe Culverts 150 mm dia. Polyethylene Linear MeterHOPE

High Density101 (5) c5 Removal of Pipes other than Pipe Culverts 200 mm dia. Polyethylene Linear Meter

HOPEHigh Density

101 (5) c6 Removal of Pipes other than Pipe Culverts 250 mm dia. Polyethylene Linear MeterHOPE

High Density101 (5) c7 Removal of Pipes other than Pipe Culverts 300 mm dia. Polyethylene Linear Meter

HOPE101 6 Removal of Structures and Obstruction Concrete Cubic Meter101 7 a Removal of Structures and Obstruction Steel Kiloaram101 7 b Removal of Structures and Obstruction Steel H-Piles Kiloaram101 7 c Removal of Structures and Obstruction RSB KiloQram101 8 Removal of ExistinQ Guardrails Linear Meter101 9 Removal of ExistinQ Guardrail Posts Each

101 10) Removal of Existina Road Sians Each

Page 4 VOL II

Page 8: Standardized Pay Items of Works for Civil Works Construction for

ITEM 102 - EXCAVATIONPay Item Suffix Description

Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

102 1 Unsuitable Excavation Cubic Meter

102 2 Sumlus Common Excavation Cubic Meter

102 3 a Surolus Rock Excavation Soft Cubic Meter

102 3 b Surolus Rock Excavation Hard Cubic Meter

102 4 Sumlus Unclassified Excavation Cubic Meter

ITEM 103 - STRUCTURE EXCAVATIONPay Item Suffix Description

Valid Values Unit Of Measure(Numberl I (Subscri Thickness/Sizes Class Others

103 1 a Structure Excavation Common Soil Cubic Meter

103 1 b Structure Excavation Soft Rock Cubic Meter

103 1 c Structure Excavation Hard Rock Cubic Meter

; 103 2 a Bridae Excavation Common Soil Cubic Meter, 103 2 b Bridae Excavation Soft Rock Cubic Meter, 103 2 c Bridae Excavation Hard Rock Cubic Meter

103 3 Foundation Fill Cubic Meter

103 4 Excavation ordered below Plan elevation Cubic Meter

103 5 a Shorina. cribbina and related works ShorinCi Lumo sum

103 5 b Shorina, cribbing and related works Cribbina/CofferdamminCi Lumo sum

103 6 a Pice culverts and drain excavation • Common Soil Cubic Meter

103 6 b Pice culverts and drain excavation Soft Rock Cubic Meter

103 6 c Pine culverts and drain excavation Hard Rock Cubic Meter

ITEM 104 - EMBANKMENTPay Item Suffix Description

Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes Class Others

104 1 al Embankment from roadwav excavation Common Soil Cubic Meter

104 1 a2 Embankment from roadway excavation Soft Rock Cubic Meter

104 1 a3 Embankment from roadwav excavation Hard Rock Cubic Meter

104 1 bl Embankment from borrow Common Soil Cubic Meter

104 1 b2 Embankment from borrow Soft Rock Cubic Meter

104 1 b3 Embankment from borrow Hard Rock Cubic Meter

104 1 b4 Embankment from borrow Granular Coarse Material Cubic Meter

104 1 bS Embankment from borrow Granular Fine Material Cubic Meter

104 2 a Selected Borrow for toooina Case 1 Cubic Meter

104 2 b Selected Borrow for toooina Case 2 Cubic Meter

104 3 Earth Berm Cubic Meter

104 4 Boulder Fill Cubic Meter

Page 5 VOL II

Page 9: Standardized Pay Items of Works for Civil Works Construction for

Item 105 SUBGRADEPREPARATIONPay Item Suffix

Description Valid ValuesUnit Of Measure~Number) (Subscri Thickness/Sizes Class Others

105 (1 a Subgrade Preparation Common Material Square Meter105 1 b Subgrade Preparation Existing Pavement Square Meter105 1 c Subarade Preparation Unsuitable Material Square Meter105 1 d Subarade Preoaration Hard Rock Material Square Meter105 1 e Subarade Preoaration Soft Rock Material Square Meter105 1) f Subarade Preoaration Unclassified Material Square Meter

ITEM 106 - COMPACTION EQUIPMENT AND DENSITY CONTROL STRIPSPay Item Suffix

Description Valid ValuesUnit Of Measure(Number) (Subscri Thickness/Sizes Class Others

106 (1) Compaction Equipment and Denstiy Controls Strips Common Material Square Meter

*Unless otherwise provided, the cost of constnJcting the control strip will be considered incidental to the cost of the work item for which a control strip is required. Payment for the work item shall be deemed to include compensationfor performing the work herein specified and the fumishing of all materials, labors, tools, equipment and incidentals necessary to constnJct the density control strip. No payment will be made for any material used in the construction

of unacceptable control strip.

ITEM 107 - OVERHAULPay Item Suffix

Description Valid Values Unit Of Measure(Number) LSubscri Thickness/Sizes Class Others107 1 Overhaul Cubic Meter107 2 Overhaul Kilometer107 3 Overhaul of Borrow Case 1 Cubic Meter107 4 Overhaul of Borrow Case 1 Kilometer

PART D - SUBBASEAND BASECOURSEITEM 200 AGGREGATE SUBBASE COURSEPay Item Suffix

Description Valid Values Unit Of Measure(Number) _(Subscri Thickness/Sizes I Class I Others200 (1) . Aggregate Subbase Course I I Cubic Meter

ITEM 201 - AGGREGATE BASECOURSEPay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes I Class I Others201 (1) Aqqreqate Base Course I I Cubic Meter

ITEM 202 - CRUSHED AGGREGATEBASECOURSEPay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes I Class 1 Others202 (1) Crushed Aaaregate Base Course I I Cubic Meter

Page 6 VOL II

Page 10: Standardized Pay Items of Works for Civil Works Construction for

ITEM 203 - UME STABIUZED ROAD MIX BASECOURSEPay Item Suffix Description Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes Class Others203 (1) a Lime Stabilized Road Mix Base Course New Soil Aggregate Cubic Meter203 (I) b Lime Stabilized Road Mix Base Course Salvaaed Soil Aaareaate Cubic Meter

ITEM 204 - PORTLAND CEMENT STABIUZED ROAD MIX BASECOURSEPay Item Suffix Description Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes Class Others204m a Portland Cement Stabilized Road Mix Base Course New Soil Aaareaate Cubic Meter204 (I) b Portland Cement Stabilized Road Mix Base Course Salvaaed Soil Aaareaate Cubic Meter

Item 205 - ASPHALT STABIUZED ROAD MIX BASECOURSEPay Item Suffix Description Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes Class Others205 (1) a Asohalt Stabilized Road Mix Base Course New Soil Aaareaate Cubic Meter205 (1) b Asohalt Stabilized Road Mix Base Course Salvaaed Soil Aaareaate Cubic Meter

ITEM 206 - CHEMICALLY STABIUZED ROAD MIX SUB-BASE/BASE COURSEPay Item Suffix Description Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes 1 Class T Others206 (1) Polvmer-Based Chemical Soil Additive I I Liter

ITEM 207 - PORTLAND CEMENT TREATED PLANT MIX BASECOURSEPay Item Suffix Description Valid Values Unit Of Measute(Numberl (Subscri Thickness/Sizes Class Others207TfY a Portland Cement treated Plant Mix Course New Soil Aaareaate Cubic Meter20](1) b Portland Cement treated Plant Mix Course Salvaaed Soil Aaareaate Cubic Meter

ITEM 208 - AGGREGATE STOCKPILEPay Item Suffix Description Valid Values Unit Of Measure(Numberl I (Subscri Thickness/Sizes Class Others208 (1) Aaareaate Stockoile Cubic Meter

ITEM 209 - ASPHALT TREATED PLANT MIX BASECOURSEPay Item Suffix Description Valid Values Unit Of Measure(Numberl . (Subscri Thickness/Sizes Class T Others209 (I) Asohalt Treated Plant Mix Base Course I Cubic Meter

PART E - SURFACE COURSESITEM 300 - AGGREGATESURFACE COURSEPay Item Suffix Description Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes Class others300 (1) Gravel Surface Course Cubic Meter300m Crushed Aaareaate Surface Course Cubic Meter

Page 7 VOL II

Page 11: Standardized Pay Items of Works for Civil Works Construction for

ITEM 301 BITUMINOUS PRIME COATPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

301 1 a Bituminous Prime Coat - MC- Cut-back Asphalt Grade 30 Square Meter301 1 b Bituminous Prime Coat - MC- Cut-back Asphalt Grade 70 Square Meter301 1 c Bituminous Prime Coat - MC- Cut-back Asohalt Grade 250 Sauare Meter301 1 d Bituminous Prime Coat - MC- Cut-back Asphalt Grade 800 Square Meter301 1 e Bituminous Prime Coat - MC- Cut-back Asphalt Grade 3000 Sauare Meter301 2 a Bituminous Prime Coat - RC - Cut-back Asphalt Grade 70 Square Meter301 2 b Bituminous Prime Coat - RC - Cut-back Asphalt Grade 250 Square Meter301 2 c Bituminous Prime Coat - RC - Cut-back Asphalt Grade 800 Square Meter301 (2 d Bituminous Prime Coat - RC - Cut-back Asohalt Grade 3000 Sauare Meter

ITEM 302 BITUMINOUS TACK COATPay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others302 1 a Bituminous Tack Coat - RC - Cut-back Asphalt Grade 70 Square Meter302 1 b Bituminous Tack Coat - RC - Cut-back Asphalt Grade 250 Square Meter302 1 c Bituminous Tack Coat - RC - Cut-back Asphalt Grade 800 Square Meter302 1 d Bituminous Tack Coat - RC - Cut-back Asphalt Grade 3000 Square Meter302 2 Emulsified Asohalt Sauare Meter

ITEM 303 - BITUMINOUS SEALCOATPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

303 (1 a Cover Aaareaate Type 2 Tonne303 1 b Cover Aqqreqate Tvoe 3A Tonne303 1 c Cover Aaareaate Type 3B Tonne303 2 a Bituminous Seal Coat - MC-Cut-back Asphalt Grade 30 Tonne303 2 b Bituminous Seal Coat - MC-Cut-back Asphalt Grade 70 Tonne303 2 c Bituminous Seal Coat - MC-Cut-back Asphalt Grade 250 Tonne303 2 d Bituminous Seal Coat - MC-Cut-back Asphalt Grade 800 Tonne303 2 e Bituminous Seal Coat - MC-Cut-back Asohalt Grade 3000 Tonne303 3 a Bituminous Seal Coat - RC-Cut-back Asohalt Grade 70 Tonne303 3 b Bituminous Seal Coat - RC-Cut-back Asphalt Grade 250 Tonne303 3 c Bituminous Seal Coat - RC-Cut-back Asphalt Grade 800 Tonne303 3 d Bituminous Seal Coat - RC-Cut-back Asohalt Grade 3000 Tonne303 4 Asohalt Cement Pen. Gr. Tonne

ITEM 304 - BITUMINOUS SURFACETREATMENTPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

304 (1) Aaaregate Grading Tonne304 (2) Asphalt Cement Pen. Grade Tonne

•.•..',,-_ •...~..._-~--.~...• "._ .." -'. "'-~---- -...-.--- .-~._-- --.-

Page 8 VOL II

Page 12: Standardized Pay Items of Works for Civil Works Construction for

304 3 a Bituminous Surface Treatment - RC-Cut-back Asphalt Grade 70 Tonne304 3 b Bituminous Surface Treatment - RC-Cut-back Asphalt Grade 250 Tonne304 3 c Bituminous Surface Treatment - RC-Cut-back Asphalt Grade 800 Tonne304 3 d Bituminous Surface Treatment - RC-Cut-back Asphalt Grade 3000 Tonne304 4 a Bituminous Surface Treatment - MC-Cut-back Asphalt Grade 30 Tonne304 4 b Bituminous Surface Treatment - MC-Cut-back Asphalt Grade 70 Tonne304 4 c Bituminous Surface Treatment - MC-Cut-back Asohalt Grade 250 Tonne304 4 d Bituminous Surface Treatment - MC-Cut-back Asohalt Grade 800 Tonne304 4 e Bituminous Surface Treatment - MC-Cut-back Asohalt Grade 3000 Tonne304 5 Emulsified Asohalt Tonne

ITEM 304A - SLURRY SYSTEM FOR ROAD SURFACETREATMENTPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others304A 1 Slurry Surface Treatment (ssn Square Meter304A 2 Slurry Seal Square Meter304A 3 Micro-surfacina Sauare Meter

ITEM 305 - BITUMINOUS PENETRATION MACADAM PAVEMENTPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

305 1 Aaareaates Tonne305 2 Asohalt Cement Tonne305 3 a Bituminous Penetration Macadam Pavement - RC-Cut-back Asphalt Grade 70 Tonne305 3 b Bituminous Penetration Macadam Pavement - RC-Cut-back Asohalt Grade 250 Tonne305 3 c Bituminous Penetration Macadam Pavement - RC-Cut-back Asphalt Grade 800 Tonne305 3 d Bituminous Penetration Macadam Pavement - RC-Cut-back Asohalt Grade 3000 Tonne305 4 Emulsified Asohalt Tonne

ITEM 306 - BITUMINOUS ROAD MIX SURFACE COURSEPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

306 (1) Aaareaate for Bituminous Road Mix Surface Course Tonne306 (2) Bituminous Material for Bituminous Road Mix Surface Course Tonne

ITEM 307 - BITUMINOUS PLANT-MIX SURFACE COURSE - GENERAL*The area to be paid for under this item shall be the number of Square Meters (m2) of asphalt pavement placed, compaded and accepted based on the ThickneSS/Sizesand densities of the cores taken.

ITEM 308 - BITUMINOUS PLANT-MIX SURFACE COURSE, COLD-LAIDPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes I Class I Others

308 (1) Bituminous Plant-Mix Surface Course. Cold-Laid I I Sauare Meter

Page 9 VOL II

Page 13: Standardized Pay Items of Works for Civil Works Construction for

ITEM 309 - BITUMINOUS PLANT-MIX (STOCKPILE MAINTENANCE MIXTURE)Pay Item Suffix Description Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes I Class I Others

309 (1) Bituminous Plant-Mix (Stockoile Maintenance Mixture) I I Cubic Meter

ITEM 310 BITUMINOUS CONCRETE SURFACECOURSE, HOT-LAIDPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

310 (1) a Bituminous Concrete Surface Wearing Course, Hot-Laid 30mm Square Meter310 1) b Bituminous Concrete Surface Wearinq Course. Hot-Laid 40mm Square Meter310 1) c Bituminous Concrete Surface Wearinq Course. Hot-Laid 50mm Square Meter310 2) Bituminous Concrete Surface Binder Course, Hot-Laid 50mm Square Meter310 3 ASDhaltic Concrete With Lahar as Fine Aqqreoate ReDlacement Square Meter310 4 a Bituminous Concrete Surface Wearinq Course Stone Mastic 30mm Square Meter310 4 b Bituminous Concrete Surface Wearinq Course. Stone Mastic 40mm Square Meter310 4 c Bituminous Concrete Surface Wearinq Course Stone Mastic 50mm Square Meter310 5 Bituminous Concrete Surface Binder Course Stone Mastic 50mm Square Meter310 6 a Bituminous Concrete Surface Wearinq Course PMB 30mm Square Meter310 (6) b Bituminous Concrete Surface Wearinq Course PMB 40mm Square Meter310 (6) c Bituminous Concrete Surface Wearinq Course PMB 50mm Square Meter

ITEM 311 - PORTLAND CEMENT CONCRETE PAVEMENTPay Item Suffix Description Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes Class Others

311 1 a PeC Pavement Unreinforced 0.15 m thick 14 days Square Meter311 1 b PeC Pavement Unreinforced 0.20 m thick 14 days Square Meter311 1 cl PeC Pavement Unreinforced 0.23 m thick 14 days Square Meter311 1 c2 PeC Pavement Unreinforced 0.23 m thick 7 days Square Meter311 1 c3 PCC Pavement Unreinforced 0.23 m thick 3 days Square Meter311 1 dl PCC Pavement Unreinforced 0.25 m thick 14 days Square Meter311 1 d2 PeC Pavement Unreinforced 0.25 m thick 7 days Square Meter311 1 d3 PeC Pavement Unreinforced 0.25 m thick 3 days Square Meter311 1 el PeC Pavement Unreinforced 0.28 m thick 14 days Square Meter311 1 e2 PeC Pavement Unreinforced 0.28 m thick 7 days Square Meter311 1 e3 PCC Pavement Unreinforced 0.28 m thick 3 days Square Meter311 1 f1 PCC Pavement Unreinforced 0.30 m thick 14 days Square Meter311 1 f2 PeC Pavement Unreinforced 0.30 m thick 7 days Square Meter311 1 f3 PCC Pavement Unreinforced 0.30 m thick 3 days Square Meter311 1 ql PeC Pavement Unreinforced 0.33 m thick 14 days Square Meter311 1 g2 PeC Pavement Unreinforced 0.33 m thick 7 days Square Meter311 1 q3 PeC Pavement Unreinforced 0.33 m thick 3 days Square Meter311 1 hl PeC Pavement Unreinforced 0.35 m thick 14 days Square Meter311 1 h2 PeC Pavement Unrei nforced 0.35 m thick 7 days Square Meter311 1 h3 PCC Pavem.§!ltillnreinforc~_,_~, __ .~=~ ___ .~,~_., •.,,,..,.___ ,P,~J.~JI1JhicJs__ 3 days S.9!:Iare..t't~~_r___~_....•_,_.~_".."'_ ..~'-~"~ .--

Page 10 VOL II

Page 14: Standardized Pay Items of Works for Civil Works Construction for

311 2 a PeC Pavement Reinforced 0.15 m thick 14 days Sauare Meter311 2 b PeC Pavement Reinforced . 0.20 m thick 14 days Sauare Meter311 2 c1 PeC Pavement Reinforced 0.23 m thick 14 days Square Meter311 2 c2 PeC Pavement Reinforced) 0.23 m thick 7 davs Square Meter311 2 c3 PeC Pavement Reinforced 0.23 m thick 3 davs ;ouare Meter311 2 d1 PeC Pavement Reinforced 0.25 m thick 14 days ;ouare Meter311 2 d2 PeC Pavement Reinforced 0.25 m thick 7 days )quare Meter311 2 d3 PeC Pavement Reinforced 0.25 m thick 3 days Sauare Meter311 2 e1 PeC Pavement Reinforced 0.28 m thick 14 days Sauare Meter311 2 e2 PeC Pavement Reinforced 0.28 m thick 7 days Sauare Meter311 2 e3 PeC Pavement (Reinforced 0.28 m thick 3 davs Sauare Meter311 2 f1 PeC Pavement (Reinforced 0.30 m thick 14 days auare Meter311 2 f2 PeC Pavement (Reinforced 0.30 m thick 7 days auare Meter311 2 f3 PeC Pavement Reinforced 0.30 m thick 3 davs auare Meter311 2 q1 PeC Pavement Reinforced 0.33 m thick 14 days Square Meter311 2 q2 PeC Pavement Reinforced 0.33 m thick 7 days Square Meter311 2 03 PeC Pavement Reinforced 0.33 m thick 3 days Sauare Meter311 2 h1 PeC Pavement Reinforced 0.35 m thick 14 days Sauare Meter311 2 h2 PeC Pavement Reinforced 0.35 m thick 7 days Sauare Meter311 2 h3 PCC Pavement Reinforced 0.35 m thick 3 days Sauare Meter311 3 a1 PeC Pavement Reinforced with Wire Mesh) 0.23 m thick 14 days Sauare Meter311 3 a2 PeC Pavement Reinforced with Wire Mesh) 0.23 m thick 7 days Sauare Meter311 3 a3 PeC Pavement Reinforced with Wire Mesh 0.23 m thick 3 days Sauare Meter311 3 b1 PeC Pavement Reinforced with Wire Mesh 0.25 m thick 14 days Sauare Meter311 3 b2 PeC Pavement Reinforced with Wire Mesh 0.25 m thick 7 days Sauare Meter311 3 b3 PeC Pavement Reinforced with Wire Mesh 0.25 m thick 3 days Sauare Meter311 3 c1 PeC Pavement Reinforced with Wire Mesh 0.28 m thick 14 days Sauare Meter311 3 c2 PeC Pavement Reinforced with Wire Mesh 0.28 m thick 7 days Sauare Meter311 3 c3 PeC Pavement Reinforced with Wire Mesh 0.28 m thick 3 days Sauare Meter311 3 d1 PeC Pavement Reinforced with Wire Mesh 0.30 m thick 14 days Sauare Meter311 3 d2 PeC Pavement Reinforced with Wire Mesh 0.30 m thick 7 days Sauare Meter311 3 d3 PeC Pavement Reinforced with Wire Mesh 0.30 m thick 3 days Sauare Meter311 3 e1 PeC Pavement Reinforced with Wire Mesh 0.33 m thick 14 days Sauare Meter311 3 e2 PeC Pavement Reinforced with Wire Mesh 0.33 m thick 7 days Sauare Meter311 3 e3 PeC Pavement Reinforced with Wire Mesh 0.33 m thick 3 days Sauare Meter311 3 f1 PeC Pavement Reinforced with Wire Mesh 0.35 m thick 14 days Sauare Meter311 3 f2 PeC Pavement Reinforced with Wire Mesh 0.35 m thick 7 days Sauare Meter311 (3) f3 PeC Pavement Reinforced with Wire Mesh 0.35 m thick 3 davs Sauare Meter311 (4) a1 PCC Pavement with Coralline Materials as Coarse Aggregates (Unreinforced) 0.15 m thick 14 days Square Meter

311 (4) a2 PCC Pavement with Coralline Materials as Coarse Aggregates (Unreinforced) 0.20 m thick 14 days Square Meter

311 (4) a3 PeC Pavement with Coralline Materials as Coarse Aggregates (Unreinforced) 0.23 m thick 14 days Square Meter

Page 11 VOLII

Page 15: Standardized Pay Items of Works for Civil Works Construction for

311 (4) a4 PCC Pavement with Coralline Materials as Coarse Aggregates (Unreinforced) 0.25 m thick 14 days Square Meter,, 311 (4) as PCC Pavement with Coralline Materials as Coarse Aggregates (Unreinforced) 0.28 m thick 14 days Square Meter

311 (4) b1 PeC Pavement with Coralline Materials as Coarse Aggregates (Reinforced) 0.15 m thick 14 days Square Meter

':311 (4) b2 PCC Pavement with Coralline Materials as Coarse Aggregates (Reinforced) 0.20 m thick 14 days Square Meter

,311 (4) b3 PeC Pavement with Coralline Materials as Coarse Aggregates (Reinforced) 0.23 m thick 14 days Square Meter

311 (4) b4 PeC Pavement with Coralline Materials as Coarse Aggregates (Reinforced) 0.25 m thick 14 days Square Meter

311 (4) b5 PeC Pavement with Coralline Materials as Coarse Aggregates (Reinforced) 0.28 m thick 14 days Square Meter

311 5 a1 PeC Pavement with Dolomites as Aaareqates Unreinforced 0.15 m thick 14 davs Sauare Meter311 5 a2 PCC Pavement with Dolomites as Aaareaates Unreinforced 0.20 m thick 14 days Sauare Meter311 5 a3 PCC Pavement with Dolomites as Aaareaates Unreinforced 0.23 m thick 14 davs Sauare Meter311 5 a4 PCC Pavement with Dolomites as Aaareaates Unreinforced 0.25 m thick 14 days Sauare Meter

'··311 5 as PeC Pavement with Dolomites as Aaareaates Unreinforced 0.28 m thick 14 davs Sauare Meter311 5 b1 PeC Pavement with Dolomites as Aaareqates Reinforced 0.15 m thick 14 davs Sauare Meter311 5 b2 PeC Pavement with Dolomites as Aaareaates Reinforced 0.20 m thick 14 days Sauare Meter311 5 b3 PCC Pavement with Dolomites as Aaareaates Reinforced 0.23 m thick 14 davs Sauare Meter311 5 b4 PeC Pavement with Dolomites as Aaareaates Reinforced 0.25 m thick 14 days Sauare Meter311 (5) b5 PeC Pavement with Dolomites as Aaareaates Reinforced 0.28 m thick 14 days Sauare Meter

ITEM 313 - ROCK ASPHALT, HOT LAIDPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes I Class I Others

313 (1) Rock Asohalt I I Sauare Meter

PART F - BRIDGE CONSTRUCTION'ITEM 400 - PILINGPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

400 1 Untreated Timber Piles furnished Meter400 2 Treated Timber Piles. preservative furnished Meter400 3 a Steel H-Piles. furnished 305mmx305mm 79 ka/m Meter400 3 b Steel H-Piles. furnished 305mmx305mm 94 ka/m Meter400 3 c Steel H-Piles. furnished 305mmx305mm 110 ka/m Meter400 3 d Steel H-Piles. furnished 305mmx305mm 125 ka/m Meter400 4 a Precast Concrete Piles. furnished 40Ox400 mm Meter400 4 b Precast Concrete Piles furnished 450x450 mm Meter400 5 a Precast. Prestresssed Concrete Piles. furnished 400x400 mm Meter400 5 b Precast. Prestresssed Concrete Piles. furnished 450x450 mm Meter400 6 Structural Steel Sheet Piles. furnished Meter

Page 12 VOL II

Page 16: Standardized Pay Items of Works for Civil Works Construction for

400 7 Precast Concrete Sheet Piles, furnished Meter400 8 Untreated Timber Piles, driven Meter400 9 Treated Timber Piles driven Meter

400 10} Steel H-Piles driven Meter400 11) Steel Pipes Piles Meter400 12} Structural Steel Sheet Piles driven Meter400 (13) Precast Concrete Sheet Piles. driven Meter400 14 Precast Concrete Piles driven Meter400 15 Precast. Prestresssed Concrete Piles, driven Meter400 16 Test Piles furnished and driven Meter400 17 a Concrete Piles cast in Drilled Holes 0.80 Meter400 17 b Concrete Piles cast in Drilled Holes 1.00 Meter400 17) c Concrete Piles cast in Drilled Holes 1.20 Meter400 17 d Concrete Piles cast in Drilled Holes 1.50 Meter400 17 e Concrete Piles cast in Drilled Holes 1.80 Meter400 17 f Concrete Piles cast in Drilled Holes 2.00 Meter400 17 q Concrete Piles cast in Drilled Holes 2.50 Meter400 17 h Concrete Piles cast in Drilled Holes 2.80 Meter400 17 i Concrete Piles cast in Drilled Holes 3.00 Meter400 18 a Concrete Piles cast in Steel Shells 400mm dia. Meter400 18 b Concrete Piles cast in Steel Shells 500mm dia. Meter400 19 a Concrete Piles cast in Steel Pipes 400mm dia. Meter400 19 b Concrete Piles cast in Steel Pioes 500mm dia. Meter400 20 Pile Shoes Each400 (21 Solices Each400 22 Load Tests Each400 23 a Bored Piles 0.80 Meter400 23 b Bored Piles 1.00 Meter400 23 c Bored Piles 1.20 Meter400 23 d Bored Piles 1.50 Meter400 23 e Bored Piles 1.80 Meter400 23 f Bored Piles 2.00 Meter400 23 q Bored Piles 2.50 Meter400 23 h Bored Piles 2.80 Meter400 23 i Bored Piles 3.00 Meter400 24 a1 Permanent Casinq 0.80 10mm thick Meter400 24 a2 Permanent Casinq 0.80 12mm thick Meter400 24 a3 Permanent Casino 0.80 16mm thick Meter400 24 b1 Permanent Casino 1.00 10mm thick Meter400 24 b2 Permanent Casino 1.00 12mm thick Meter400 24 b3 Permanent Casino 1.00 16mm thick Meter400 24 c1 Permanent Casinq 1.20 10mm thick Meter400 24 c2 Permanent Casinq 1.20 12mm thick Meter400 24 c3 Permanent Casino 1.20 16mm thick Meter400 24 d1 Permanent Casinq 1.50 lOmm thick Meter

Page 13 VOLII

Page 17: Standardized Pay Items of Works for Civil Works Construction for

400 24) d2 Permanent Casinq 1.50 12mm thick Meter400 24) d3 Permanent Casinq 1.50 16mm thick Meter400 24) e1 Permanent Casinq 1.80 10mm thick Meter400 (24 e2 Permanent Casinq 1.80 12mm thick Meter400 24 e3 Permanent Casinq 1.80 16mm thick Meter400 24 f1 Permanent Casinq 2.00 lOmm thick Meter400 24 f2 Permanent Casinq 2.00 12mm thick Meter400 24 f3 Permanent Casinq 2.00 16mm thick Meter400 24 q1 Permanent Casinq 2.50 10mm thick Meter400 24 q2 Permanent Casinq 2.50 12mm thick Meter400 24 a3 Permanent Casina 2.50 16mm thick Meter400 24 h1 Permanent Casinq 2.80 10mm thick Meter400 (24) h2 Permanent Casinq 2.80 12mm thick Meter400 24 h3 Permanent Casinq 2.80 16mm thick Meter400 24 i1 Permanent Casinq 3.00 lOmm thick Meter400 24 i2 Permanent Casinq 3.00 12mm thick Meter400 24 i3 Permanent Casinq 3.00 16mm thick Meter400 25 Permanent Casinq Kiloqram400 26 Solicina of R.C. Piles with Eooxv Each400 27 a Pile Inteqritv Testinq Crosshole-Sonic Each400 27 b Pile Intearitv Testina Low Strain Each400 28 Hiqh Strain Dvnamic Testinq (P.D.A) Each400 29 a Sand Comoaction Pile 0.6 Meter400 29 b Sand Comoaction Pile 0.7 Meter400 29 c Sand Comoaction Pile 0.8 Meter400 30 a Gravel Comoaction Pile 0.6 Meter400 30) b Gravel Compaction Pile 0.7 Meter400 (30) c Gravel Comoaction Pile 0.8 Meter

1 Metal Railin Steel1 Metal Railin Aluminum2 a Concrete Railin Standard2 b Concrete Railin Balluster2 c Concrete Railin Para et3 Wooden Railin4 Stone and Brick Railin

Page 14 VOL II

Page 18: Standardized Pay Items of Works for Civil Works Construction for

ITEM 403 - METAL STRUCTURESPay Item Suffix

Description Valid ValuesUnit Of Measure(Number) (Subscri Thickness/Sizes Class Others

403 1 Structural Steel, furnished KiloQram403 2 Structural Steel, fabricated KiloQram403 3 Structural Steel, erected KiloQram403 4 Structural Steel, furnished and fabricated KilOQram403 5 Structural Steel, furnished fabricated and erected KiloQram403 6) Structural Steel, painting works Sauare Meter

ITEM 404 - REINFORCING STEELPay Item Suffix

Description Valid ValuesUnit Of Measure(Number) (Subscri Thickness/Sizes Class Others

404 (1) a ReinforcinQ Steel Grade 40 Kilogram404 (1) b ReinforcinQ Steel Grade 60 KiloQram

ITEM 404A - EPOXY-COATED REINFORCING STEEL BARSPay Item Suffix

Description Valid ValuesUnit Of Measure(Number) I (Subscri Thickness/Sizes Class Others

404A (1) a EooxY-Coated Reinforcing Steel Bars Grade 40 Kilogram404A (1) b Eooxy-Coated Reinforcina Steel Bars Grade 60 Kilogram

ITEM 405 - STRUCTURAL CONCRETEPay Item Suffix

Description Valid ValuesUnit Of Measure(Number) (Subscri Thickness/Sizes Class Others

405 1 al Structural Concrete 20.68MPa A 7 days Cubic Meter405 1 a2 Structural Concrete 20.68MPa A 14 days Cubic Meter405 1 a3 Structural Concrete 20.68MPa A 28 days Cubic Meter405 1 bl Structural Concrete 27.58 Mpa A 7 days Cubic Meter405 1 b2 Structural Concrete 27.58 MPa A 14 days Cubic Meter405 1 b3 Structural Concrete 27.58 Mea A 28 days Cubic Meter405 2 a Structural Concrete 20.68MPa B Cubic Meter405 2 b Structural Concrete 27.58 Mea B Cubic Meter405 3 a Structural Concrete 20.68MPa C Cubic Meter405 3 b Structural Concrete 27.58 Mpa C Cubic Meter405 4 al Structural Concrete 34.47 Mpa P 7 days Cubic Meter405 4 a2 Structural Concrete 34.47 Moa P 14 days Cubic Meter405 4 a3 Structural Concrete 34.47 Mpa P 28 days Cubic Meter405 4 bl Structural Concrete 41.37 Mpa P 7 days Cubic Meter405 4 b2 Structural Concrete 41.37 Moa P 14 days Cubic Meter405 4) b3 Structural Concrete 41.37 Moa P 28 days Cubic Meter405 5 Seal Concrete Cubic Meter405 (6) Structural Concrete oaintinQ works Sauare Meter

Page 15 VOL II

Page 19: Standardized Pay Items of Works for Civil Works Construction for

ITEM 406 - PRESTRESSEDCONCRETE STRUCTURESPay Item Suffix Description

Valid Values Unit Of Measure{Numberl (Subscri Thickness/Sizes Class/TvDe Others

406 (1) a1 Prestressed Structural Concrete Members Tvoe IIIL=lSm I -Girders Each

406 (1) a2 Prestressed Structural Concrete Members Tvoe IV L~20m I-Girders Each

406 (1) a3 Prestressed Structural Concrete Members Type IV-A L=2Sm I-Girders Each

406 (1) a4 Prestressed Structural Concrete Members Type IV-B L=30m I-Girders Each

406 1 as Prestressed Structural Concrete Members Tvoe V L=35m I-Girders Each

406 1 a6 Prestressed Structural Concrete Members Tvoe VI L=40m I-Girders Each

406 2 a Prestressed Concrete T-Girder Lumo Sum

406 2 b Prestressed Concrete Box Girder Lumo Sum

406 3 a Prestressed Concrete T-Girder Cubic Meter

406 3 b Prestressed Concrete Box Girder Cubic Meter

ITEM 407- CONCRETE STRUCTURESPay Item Suffix Description

Valid Values Unit Of Measure{Numberl (Subscri Thickness/Sizes Class Others

407 1) Concrete (Refer to Item 405) A Cubic Meter

407 2 Concrete Post/Baluster RailinQs Each

407 3 Paraoet Walls Cubic Meter

407 4 PilinQ(Refer to Item 400) Linear Meter

407 5 Structure Excavation (Refer to Item 103) Cubic Meter

407 6 Sidewalk Concrete (Refer to Item 60lf Cubic Meter

407 7 ReinforcinQ Steel Bars (Refer to Item 404) Grade 40 KiloQram

407 8 Lean Concrete Class B (16.5 MPa) Cubic Meter*When more than one item is specified, means of identification shall be inserted in parenthesis immediately after the Pay Item and letter suffixes shall be included within the parenthesis of the Pay Item Number.

ITEM 408- STEEL BRIDGESPay Item Suffix Description

Valid Values Unit Of Measure{Numberl {Subscri Thickness/Sizes Class Others

408 (1) Steel Bridges Lump Sum

*The quantities, measured as prescribed above, shall be paid for at the contract until price for the several Pay Items which price and payments shall be full compensation for furnishing, preparing, fabricating, transporting, placing anderecting all structural steel and all other materials for the complete structure; for all shop work, painting and field work; for all labor, equipment, tools and incidentals necessary to complete the Item. Such payment shall constitute full

payment for the completed structure ready for use, and no allowance shall be made for cofferdam construction, falsework, or other erection expenses.

Page 16 VOL II

Page 20: Standardized Pay Items of Works for Civil Works Construction for

ITEM 409 - WELDED STRUCTURAL STEELPay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others/ 409 (1)* Welded Structural Steel Lump Sum

*Unless otherwise provided in the Special Provisions, welded structural steel structures shall not be measured and paid for separately, but the cost thereof shall be considered as induded in the contract price for other Items.

ITEM 410 - TREATED AND UNTREATED TIMBERPay Item Suffix

Description Valid Values Unit Of Measure(,Number) (Subscri Thickness/Sizes Class Others. 410 (1) Timber Cubic Meter410 (2) Treated Timber Cubic Meter

ITEM 411 - PAINTPay Item Suffix

Description Valid.Values Unit Of Measure(Numberl (Subscri Thickness/Sizes Class Others411 (1)* Paint Lumo Sum411 (1)* Paint Sauare Meter

*Painting shall not be measured and paid for separately, but the cost thereof shall be considered as induded in the contract unit price of the Items where called for.

ITEM 412 - ELASTOMERIC BEARING PADSPay Item Suffix

Description Valid ValuesUnit Of Measure(Number) (Subscri Thickness/Sizes Class Others

412 (1) Elastomeric Bearina Pads Each

ITEM 413 - PREFORMED SPONGE RUBBER AND CORK JOINT EXPANS ION FILLERS FOR CONCRETE PAVING AND STRUCTURAL CONSTRUCTIONPay Item Suffix Description Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes Class Others413 (1) a Preformed Soonqe Rubber Joint Exoansion Cubic Meter

/ 413 (1) b Preformed Cork Joint Exoansion Cubic Meter

ITEM 414 - Forms and FalseworksSuffix Valid Values

Pay Item (Subscri Description Unit Of Measure(Number) pt) Thickness/Sizes Class Others

v 414 (1) Forms and Falsework Lumo Sum

ITEM 415 - ELASTOMERIC, HOT-APPLIED JOINT SEALANT WITH SINGLE-SIZED AGGREGATESFOR BRIDGE EXPANSION JOINTSPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

y 415 (1) Elastomeric, Hot-Applied Expansion Joint Sealant with Single-SizedCubic MeterAggregates

Page 17 VOL II

Page 21: Standardized Pay Items of Works for Civil Works Construction for

ITEM 416 - CARBON AND GLASS FIBERPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

416 1) a Carbon Fiber 1 Layer Sauare Meter~ 416 1 b Carbon Fiber 2 Layers Sauare Meter

416 1 c Carbon Fiber I 3 Lavers Sauare Meter416 2 a Glass Fiber 1 Laver Square Meter416 2 b Glass Fiber 2 Layers Square Meter

, 416 2 c Glass Fiber 3 Layers Sauare Meter

ITEM 417 - BEARING DEVICESPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

V 417 (1) a Bearina Devices Steel Bearinq EachV 417 (1) b Bearinq Devices Rubber Bearing Each

V 417 (1) c Bearing DevicesHigh Damping Rubber Each

Bearing

ITEM 500 - PIPE CULVERTS AND STORM DRAINPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

500 1 a1 Pipe Culverts 610 mm dia. Class II RCPC Linear Meter500 1 a2 Pice Culverts 760 mm dia. Class II RCPC Linear Meter500 1 a3 Pipe Culverts 910 mm dia. Class II RCPC Linear Meter500 1 a4 Pice Culverts 1070 mm dia. Class II RCPC Linear Meter500 1 as Pipe Culverts 1220 mm dia. Class II RCPC Linear Meter500 1 a6 Pipe Culverts 1520 mm dia. Class II RCPC Linear Meter500 1 b1 Pipe Culverts 610 mm dia. Class IV RCPC Linear Meter500 1 b2 Pipe Culverts 760 mm dia. Class IV RCPC Linear Meter500 1 b3 Pipe Culverts 910 mm dia. Class IV RCPC Linear Meter500 1 b4 Pipe Culverts 1070 mm dia. Class IV RCPC Linear Meter500 1 b5 Pipe Culverts 1220 mm dia. Class IV RCPC Linear Meter500 1 b6 Pipe Culverts 1520 mm dia. Class IV RCPC Linear Meter500 2 Storm Drain Linear Meter

ITEM 501- UNDERDRAINSPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

501 1 Underdrain 150 mm dia. Linear Meter501 2 Blind drain . Linear Meter501 3 Granular backfill filter material for underdrains Cubic Meter

Page 18 VOL II

Page 22: Standardized Pay Items of Works for Civil Works Construction for

ITEM 502 - MANHOLES, INLETS AND CATCH BASINSPay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others502 1 a Manholes 610 mm dia. Each502 1 b Manholes 760 mm dia. Each502 1 c Manholes 910 mm dia. Each502 1 d Manholes 1070mm dia. Each502 1 e Manholes 1220mm dia. Each502 1 f Manholes 1520mm dia. Each502 2 a Inlets. tvoe 610 mm dia. Each502 2 b Inlets. tvoe 760 mm dia. Each502 2 c Inlets. tvoe 910 mm dia. Each502 2 d Inlets. tvoe 1070mm dia. Each502 2 e Inlets. tvoe 1220mm dia. Each502 2 f Inlets tvoe 1520mm dia. Each502 3 a Catch basins 610 mm dia. Each502 3 b Catch basins 760 mm dia. Each502 3 c Catch basins 910 mm dia. Each502 3 d Catch basins 1070mm dia. Each502 3 e Catch basins 1220mm dia. Each502 3 f Catch basins 1520mm dia. Each502 4 a Concrete covers 610 mm dia. Each502 4 b Concrete covers 760 mm dia. Each502 4 c Concrete covers 910 mm dia. Each502 4 d Concrete covers 1070mm dia. Each502 4 e Concrete covers 1220mm dia. Each502 4 f Concrete covers 1520mm dia. Each502 5 Metal frames and aratinas, type Pair502 6 Metal frames and covers Pair502 7 Adiustina manholes Each502 8 Adiustina catch basin Each

ITEM 503 - DRAINAGE STEELGRATING WITH FRAMEPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others503 (1) Metal frames and aratina Set503 (2) Metal frames and aratina KilOQram

ITEM 504 - CLEANING AND RECONDITIONING EXISTING DRAINAGE STRUCTURESPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others504 1 a Removina. c1eanina. stockoilina salvaaed culvert Dine 610 mm dia. Linear Meter504 1 b Removina. c1eanina. stockoilina salvaaed culvert Dine 760 mm dia. Linear Meter504 1 c Removina. c1eanina. stockoilina salvaaed culvert oipe 910 mm dia. Linear Meter504 1 d Removina. c1eanina. stockoilina salvaaed culvert pioe 1070mm dia. Linear Meter

Page 19 VOL II

Page 23: Standardized Pay Items of Works for Civil Works Construction for

504 1 e Removino. c1eanino. stockoilino salvaoed culvert oice 1220 mm dia. Linear Meter504 1 f Removino. c1eanino. stockoilino salvaoed culvert oice 1520 mm dia. Linear Meter504 2 a Removino. c1eanino. and relavino salvaoed culvert oioe 610 mm dia. Linear Meter504 2 b Removina. c1eanino. and relavino salvaoed culvert pipe 760 mm dia. Linear Meter504 2 c Removino. c1eanino. and relavino salvaoed culvert oice 910 mm dia. Linear Meter504 2 d Removina. c1eanino. and relavino salvaoed culvert pice 1070 mm dia. Linear Meter504 2 e Removino. c1eanino. and relavina salvaaed culvert oice 1220 mm dia. Linear Meter504 2 f Removina. c1eanino. and relavino salvaoed culvert oice 1520 mm dia. Linear Meter

504 (3) a Cleaning culvert pipe in place 610 mm dia., half- Linear Metersilted

504 (3) b Cleaning culvert pipe in place 760 mm dia., half- Linear Metersilted

504 (3) c Cleaning culvert pipe in place 910 mm dia., half- Linear Metersilted

504 (3) d Cleaning culvert pipe in place 1070 mm dia., half- Linear Metersilted

504 (3) e Cleaning culvert pipe in place 1220 mm dia., half- Linear Metersilted

504 (3) f Cleaning culvert pipe in place 1520 mm dia., half- Linear Metersilted

504 4) Reconditionina drainaae structures Each"'If more than one type of drainage structure is described for an Item in the Bid Schedule, letter suffixes shall be added to the item Number to differentiate between such structures.

"'If no Pay Item from the list above appears in the Bid Schedule, the pipe removed will be considered as induded in the work Item 101, Removal of Structures and Obstructions.

ITEM 505 - RIPRAP AND GROUTED RIPRAPPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others505 1 Riprap A Cubic Meter505 2 Riprap B Cubic Meter505 3 Riorao C Cubic Meter505 4 Riprap 0 Cubic Meter505 5 Grouted Riprap A Cubic Meter505 6 Grouted Riorao B Cubic Meter505 7 Grouted Riprap C Cubic Meter505 8' Grouted Riorao 0 Cubic Meter505 9' Filter laver of aranular material Cubic Meter

ITEM 506 - STONE MASONRYPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes I Class I Others506 (1) Stone Masonrv I I Cubic Meter

Page 20 vOL II

Page 24: Standardized Pay Items of Works for Civil Works Construction for

ITEM 507 - RUBBLE CONCRETEPay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes I Class I Others507(1) Rubble Concrete I I Cubic Meter

ITEM 508 - HAND-LAID ROCK EMBANKMENTPay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes I Class I others508 (1) Hand-Laid Rock Embankment I I Cubic Meter

ITEM 509 - SHEET PILESPay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class others509 (1) Sheet Piles Timber Furnished and Driven Linear Meter

509 (2) a Sheet Piles ( ) SteelSlope Protection

Linear Meter(Furnished and Driven)

509 (2) b Sheet Piles ( ) Steel Cofferdamming (FurnishedLinear Meter

and Driven)509 3 a Sheet Piles ) Concrete Furnished Linear Meter509 3 b Sheet Piles Concrete Driven Linear Meter509 3 c Sheet Piles '\ Concrete Furnished and Driven Linear Meter

J

ITEM 510 - CONCRETE SLOPE PROTECTIONPay Item Suffix

Description Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes Class others510 (1) Bed Course Granular Material Concrete Cubic Meter510 (2) Concrete SloDe Protection Cubic Meter

ITEM 511 - GABIONS AND MATTRESSESPay Item Suffix

Description Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes Class others511 1 Gabions Cubic Meter511 2 Mattresses Cubic Meter511 3 Filter Cloth Sauare Meter

ITEM 512 - EROSION CONTROL MATS, ROVING, AND CELLULARCONFINEMENT SYSTEMSPay Item Suffix Description Valid Values Unit Of Measure(Numberl I (Subscri Thickness/Sizes Class others

512 1 a Erosion Control Mat Type 1 Sauare Meter512 1 b Erosion Control Mat Type 2 Square Meter512 1 c Erosion Control Mat TVDe 3 Sauare Meter512 1 d Erosion Control Mat TYDe 4 Sauare Meter512 1 e Erosion Control Mat Type 5 Sauare Meter

Page 21 VOL II

Page 25: Standardized Pay Items of Works for Civil Works Construction for

S uare MeterS uare Meter

ITEM 513 - PERMANENT GROUND ANCHORSPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes I Class I Others

513 (1) Permanent Ground Anchor I I Linear Meter

ITEM 514 - SHOTCRETE (CONCRETE SPRAY)Pay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others514 (1) Shotcrete with reinforcing steel Square Meter514 (2) Shotcrete with reinforcinq fibers Sauare Meter

ITEM 515 - MECHANICALLY-STABIUZED EARTH (MSE) RETAINING WALLSPay Item Suffix Description Valid Values Unit Of Measure(Number) CSubscri Thickness/Sizes Class Others515 1 Mechanically-Stabilized Earth (MSE) Retaininq Walls Square Meter515 2 Select Granular Backfill Cubic Meter515 3 Structural Backfill Cubic Meter

ITEM 516 - WET STONE MASONRY (COBBLE STONE)Pay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others516 (1) Wet Stone Masonry Linear Meter516 (2) Wet Stone Masonrv Cubic Meter

ITEM 517 - DRAIN PIPEPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others517 (1) Drain Pipe Galvanized Linear Meter517 (1) Drain Pioe PVC Linear Meter

ITEM 520 - HYDROSEEDINGPay Item Suffix Description Valid Values Unit Of Measure(Number) CSubscri Thickness/Sizes I Class I Others

520 (1) Hvdroseedina I I Sauare Meter

ITEM 522 - ROCKFALLPROTECTION SYSTEMPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

522 (1) Rockfall Nettina Square Meter522 (1) Rockfall Barrier Linear Meter

Page 22 VOL II

Page 26: Standardized Pay Items of Works for Civil Works Construction for

ITEM 522A - PROTECTION SYSTEM FOR UNSTABLE SLOPEPay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others522ATf) Active Protection Svstem Square Meter522A(i) Passive/Rockfall Barrier Linear Meter

PART H - MISCELLANEOUS STRUCTURESITEM 600 - CURB AND GUTTERPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

600 1 a Concrete Curb Cast in olace Linear Meter600 1 b Asohalt Curb Cast in olace Linear Meter600 2 Concrete Gutter Cast in olace Linear Meter600 3 Curb and Gutter Cast in olace Linear Meter600 4 Concrete Curb Precast Piece600 5 Concrete Gutter Precast Piece600 6 Curb and Gutter Precast Piece

ITEM 601 - SIDEWALKPay Item Suffix Description Valid Values Unit Of Measure(Numberl (Subscri Thickness/Sizes I Class I Others

601 (1) Sidewalk 100 mm thk. I . I Sauare Meter

ITEM 602 - MONUMENTS. MARKERS AND GUIDE POSTSPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

602 1 a Riaht-of-Wav monuments Timber Each602 1 b Riaht-of-Wav monuments Concrete Each602 2 a Maintenance marker oosts Cast-in-olace Each602 2 b Maintenance marker oosts Precast Each602 2 c Maintenance marker oosts Timber Each602 3 a Kilometer DOsts Cast-in-olace Each602 3 b Kilometer oosts Precast Each602 4 a Precast Guide oosts Rectanaular Each602 4 b Cast-in-Place Guide oosts Precast Each

ITEM 603 - GUARDRAILPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

603 1 Guardrail (Wire rooe or Wire cable) Linear Meter603 2 Cable Guardrail Chain Link Fabric) Linear Meter603 3 a1 Metal Guardrail Metal Beam) Includina Post W-Beam Linear Meter603 3 a2 Metal Guardrail Metal Beam) Includina Post Thrie-Beam Linear Meter

Page 23 VOL II

Page 27: Standardized Pay Items of Works for Civil Works Construction for

603 3 b1 Metal Beam End Piece Fish Tail Each603 3 b2 Metal Beam End Piece Bull Nose Each603 4 Guardrail (Timber) Linear Meter

ITEM 604 - FENCINGPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

604 1 FencinQ Barbed wire Linear Meter604 2 Fencina Chain Link Fence Fabric Linear Meter604 3 FencinQ Posts Each604 4 Fencina Gates Each604 5) Concrete Fence inciudinQ Post SQuare Meter

ITEM 605 - ROAD SIGNPay Item Suffix Description Valid Values Unit Of Measure(Number) {Subscri Thickness/Sizes Class Others

605 (1) a1 Warning Signs 600 mm W1-1AHorizontal Alignment Sharp Each

Turn L or R

605 (1) a2 Warning Signs 750 mm W1-1BHorizontal Alignment Sharp Each

Turn L or R

605 (1) a3 Warning Signs 900 mm W1-1CHorizontal Alignment Sharp

EachTurn L or R

605 (1) b1 Warning Signs 600 mm Wl-2AHorizontal Alignment EachReverse Turn L or R

605 (1) b2 Warning Signs 750 mm Wl-2BHorizontal Alignment EachReverse Turn L or R

605 (1) b3 Warning Signs 900 mm Wl-2CHorizontal Alignment EachReverse Turn L or R

605 (1) c1 Warning Signs 600 mm Wl-3AHorizontal Alignment Curve

EachLor R

605 (1) c2 Warning Signs 750 mm Wl-3BHorizontal Alignment Curve Each

Lor R

605 (1) c3 Warning Signs 900 mm Wl-3CHorizontal Alignment Curve Each

Lor R

605 (1) d1 Warning Signs 600 mm Wl-4AHorizontal Alignment EachReverse Curve L or R

605 (1) d2 Warning Signs 750 mm Wl-4BHorizontal Alignment EachReverse Curve L or R

605 (1) d3 Warning Signs 900 mm Wl-4CHorizontal Alignment EachReverse Curve L or R

605 (1) e1 Warning Signs 600 mm Wl-5AHorizontal Alignment EachWindina Road L or R

605 (1) e2 Warning Signs 750 mm Wl-5BHorizontal Alignment EachWindina Road L or R

Page 24 VOL II

Page 28: Standardized Pay Items of Works for Civil Works Construction for

605 (1) f1 Warning Signs 600 mm Wl-6AHorizontal Alignment

EachHaimin Bend L or R

605 (1) f2 Warning Signs 750 mm Wl-6BHorizontal Alignment

EachHaimin Bend L or R

605 (1) gl Warning Signs 450 mm W2-1AIntersection and Junction

EachSigns Cross Road

605 (1) g2 Warning Signs 600 mm W2-1BIntersection and Junction

EachSigns Cross Road

605 (1) g3 Warning Signs 750 mm W2-1CIntersection and Junction

EachSigns Cross Road

605 (1) g4 Warning Signs 900 mm W2-lDIntersection and Junction

EachSigns Cross Road

Intersection and Junction605 (1) h1 Warning Signs 450 mm W2-2A Signs Staggered Side Road Each

Junction L or R

Intersection and Junction605 (1) h2 Warning Signs 600 mm W2-2B Signs Staggered Side Road Each

Junction L or R

Intersection and Junction605 (1) h3 Warning Signs 750 mm W2-2C Signs Staggered Side Road Each

Junction L or R

Intersection and Junction605 (1) h4 Warning Signs 900 mm W2-2D Signs Staggered Side Road Each

Junction L or R

605 (1) i1 Warning Signs 600 mm W2-3AIntersection and Junction

EachSigns Skewed Intersection

605 (1) i2 Warning Signs 750 mm W2-3BIntersection and Junction

EachSigns Skewed Intersection

605 (1) i3 Warning Signs 900 mm W2-3CIntersection and Junction EachSigns Skewed Intersection

605 (1) j1 Warning Signs 450 mm W2-4AIntersection and Junction

EachSigns T-Junction

Page 25 VOL II

Page 29: Standardized Pay Items of Works for Civil Works Construction for

60S (1) j2 Warning Signs 600 mm W2-4BIntersection and Junction

EachSigns T-Junction

60S (1) j3 Warning Signs 750 mm W2-4CIntersection and Junction

EachSigns T-Junction

60S (1) j4 Warning Signs 900 mm W2-4DIntersection and Junction

EachSigns T-Junction

60S (1) k1 Warning Signs 450 mm W2-5AIntersection and Junction

EachSigns V-Junction

60S (1) k2 Warning Signs 600 mm W2-5BIntersection and Junction

EachSigns V-Junction

60S (1) k3 Warning Signs 750 mm W2-5CIntersection and Junction

EachSigns V-Junction

60S (1) k4 Warning Signs 900 mm W2-5DIntersection and Junction

EachSigns Y-Junction

Intersection and Junction60S (1) 11 Warning Signs 450 mm W2-6A Signs Side Road Junction L Each

or RIntersection and Junction

60S (1) 12 Warning Signs 600 mm W2-6B Signs Side Road Junction L Eachor R

Intersection and Junction60S (1) 13 Warning Signs 750 mm W2-6C Signs Side Road Junction L Each

or RIntersection and Junction

60S (1) 14 Warning Signs 900 mm W2-6D Signs Side Road Junction L Eachor R

60S (1) m1 Warning Signs 450 mm W2-7AIntersection and Junction Each

Signs Runabout Ahead

60S (1) m2 Warning Signs 600 mm W2-7BIntersection and Junction Each

Signs Runabout Ahead

60S (1) m3 Warning Signs 750 mm W2-7CIntersection and Junction Each

Signs Runabout Ahead

60S (1) n1 Warning Signs 600 mm W2-8BIntersection and Junction Each

Signs Priority Junction

Page 26 VOL II

Page 30: Standardized Pay Items of Works for Civil Works Construction for

605 (1) n2 Warning Signs 750 mm W2-8CIntersection and Junction

EachSigns Priority Junction

605 (1) n3 Warning Signs 900 mm W2-8DIntersection and Junction

EachSigns Priority Junction

605 (1) 01 Warning Signs 600 mm W2-9BIntersection and Junction

EachSigns Priority Merging

605 (1) 02 Warning Signs 750 mm W2-9CIntersection and Junction

EachSigns Priority Merging

605 (1) 03 Warning Signs 900 mm W2-9DIntersection and Junction

EachSigns Priority Merging

605 (1) p1 Warning Signs 450 mm W2-lOAIntersection and Junction

EachSigns Priority Cross

605 (1) p2 Warning Signs 600 mm W2-10BIntersection and Junction

EachSigns Priority Cross

605 (1) p3 Warning Signs 750 mm W2-10CIntersection and Junction

EachSigns Priority Cross

605 (1) p4 Warning Signs 900 mm W2-10DIntersection and Junction

EachSigns Priority Cross

Advance Warning of Traffic605 (1) q1 Warning Signs 600 mm W3-1A Control Device Signs Each

Sianals AheadAdvance Warning of Traffic

605 (1) q2 Warning Signs 750 mm W3-1B Control Device Signs EachSinnals Ahead

Advance Warning of Traffic605 (1) q3 Warning Signs 900 mm W3-1C Control Device Signs Each

Sinnals AheadAdvance Warning of Traffic

605 (1) q4 Warning Signs 1200 mm W3-lD Control Device Signs EachSian;:Jl~Ahe;:Jd

Advance Warning of Traffic605 (1) r1 Warning Signs 450 mm W3-2A Control Device Signs Stop Each

Sinn AheadAdvance Warning of Traffic

605 (1) r2 Warning Signs 600 mm W3-2B Control Device Signs Stop EachSian Ahead

Page 27 VOL II

Page 31: Standardized Pay Items of Works for Civil Works Construction for

Advance Warning of Traffic60S (1) sl Warning Signs 750 mm W3-2C Control Device Signs Stop Each

Sian Ahead

Advance Warning of Traffic60S (1) s2 Warning Signs 450 mm W3-3A Control Device Signs Give Each

Way Sign Ahead

Advance Warning of Traffic60S (1) s3 Warning Signs 600 mm W3-3B Control Device Signs Give Each

Way Sign Ahead

Advance Warning of Traffic60S (1) s4 Warning Signs 750 mm W3-3C Control Device Signs Give Each

Way Sign Ahead

60S (1) t1 Warning Signs 450 mm W4-1ARoad Width Sign Narrow Each

Bridae

60S (1) t2 Warning Signs 600 mm W4-1BRoad Width Sign Narrow Each

Bridae

60S (1) t3 Warning Signs 750 mm W4-1CRoad Width Sign Narrow Each

Bridae

60S (1) t4 Warning Signs 450 x 700 mm W4-1PARoad Width Sign Narrow Each

Bridae

60S (1) t5 Warning Signs 600 x 900 mm W4-1PBRoad Width Sign Narrow Each

Bridae

60S (1) t6 Warning Signs 750 x 1200 mm W4-1PCRoad Width Sign Narrow Each

Bridae

60S (1) u1 Warning Signs 450 mm W4-2ARoad Width Sign Road Each

Narrows

60S (1) u2 Warning Signs 600 mm W4- 2BRoad Width Sign Road Each

Narrows

60S (1) u3 Warning Signs 750 mm W4-2CRoad Width Sign Road Each

Narrows

60S (1) u4 Warning Signs 450 x 700 mm W4-2PARoad Width Sign Road Each

Narrows

60S (1) uS Warning Signs 600 x 900 mm W4- 2PBRoad Width Sign Road Each

Narrows

60S (1) u6 Warning Signs 750 x 1200 mm W4-2PCRoad Width Sign Road Each

Narrows

60S (1) v1 Warning Signs 450 mm W4-3ARoad Width Sign Divided Each

Road

60S (1) v2 Warning Signs 600 mm W4- 3BRoad Width Sign Divided Each

Road

60S (1) v3 Warning Signs 750 mm W4- 3CRoad Width Sign Divided Each

Road

Page 28 VOL II

Page 32: Standardized Pay Items of Works for Civil Works Construction for

605 (1) v4 Warning Signs 900 mm W4- 3DRoad Width Sign Divided Each

Road

605 (1) w1 Warning Signs 450 mm W4-4A Road Width Sign End EachDivided Road

605 (1) w2 Warning Signs 600 mm W4-4B Road Width Sign End EachDivided Road

605 (1) w3 Warning Signs 750 mm W4-4C Road Width Sign End EachDivided Road

605 (1) w4 Warning Signs 900 mm W4-4DRoad Width Sign End Each

Divided Road

605 (1) xl Warning Signs 600 mm W5-1BRoad Obstacle Signs Each

Ooenine Bridee

605 (1) x2 Warning Signs 750 mm W5-1C Road Obstacle Signs EachODenine Bridee

605 (1) y1 Warning Signs 450 mm W5-2A Road Obstacle Signs EachUneven Road

605 (1) y2 Warning Signs 600 mm W5-2B Road Obstacle Signs EachUneven Road

605 (1) y3 Warning Signs 750 mm W5-2C Road Obstacle Signs EachUneven Road

605 (1) y4 Warning Signs 900 mm W5-2D Road Obstacle Signs EachUneven Road

605 (1) zl Warning Signs 450 mm W5- 3A Road Obstacle Signs Hump Each

605 (1) z2 Warning Signs 600 mm W5- 3B Road Obstacle Signs Hump Each

605 (1) z3 Warning Signs 750 mm W5-3C Road Obstacle Signs Hump Each

605 (1) z4 Warning Signs 900 mm W5- 3D Road Obstacle Signs Hump Each

605 (1) aa1 Warning Signs 600 mm W5-4B Road Obstacle Signs Steep EachDescent

605 (1) aa2 Warning Signs 750 mm W5-4C Road Obstacle Signs Steep EachDescent

605 (1) aa3 Warning Signs 900 mm W5-4D Road Obstacle Signs Steep EachDescent

605 (1) ab1 Warning Signs 450 mm W5-5A Road Obstacle Signs Steep EachClimb

605 (1) ab2 Warning Signs 600 mm W5-5BRoad Obstacle Signs Steep Each

Climb

605 (1) ab3 Warning Signs 750 mm W5-5C Road Obstacle Signs Steep EachClimb

605 (1) ac1 Warning Signs 450 mm W5-6A Road Obstacle Signs Spill EachWav

605 (1) ac2 Warning Signs 600 mm W5-6B Road Obstacle Signs Spill EachWav

Page 29 VOL II

Page 33: Standardized Pay Items of Works for Civil Works Construction for

605 (1) ac3 Warning Signs 750 mm W5-6C Road Obstacle Signs Spill EachWay605 (1) ac4 Warning Signs 900 mm W5-6D Road Obstacle Signs Spill EachWay605 (1) ad1 Warning Signs 450 mm W5-7A Road Obstacle Signs Flood Each

605 (1) ad2 Warning Signs 600 mm W5-7B Road Obstacle Signs Flood Each

605 (1) ad3 Warning Signs 750 mm W5-7C Road Obstacle Signs Flood Each

605 (1) ad4 Warning Signs 900 mm W5-7D Road Obstacle Signs Flood Each

605 (1) ae1 Warning Signs 600 mm W5-8B Road Obstacle Signs EachFallina Rocks L or R

605 (1) ae2 Warning Signs 750 mm W5-8C Road Obstacle Signs EachFallina Rocks L or R

605 (1) ae3 Warning Signs 900 mm W5-8D Road Obstacle Signs EachFallina Rocks L or R

605 (1) afl Warning Signs 450 mm W5-9A Road Obstacle Signs EachSIiDDerv Road605 (1) af2 Warning Signs 600 mm W5-9B Road Obstacle Signs EachSIiDDerv Road605 (1) af3 Warning Signs 750 mm W5-9C Road Obstacle Signs EachSIiDDerv Road605 (1) af4 Warning Signs 900 mm W5-9D Road Obstacle Signs EachSlinnerv Road605 (1) af5 Warning Signs 450mm X 700 mm W5-9PA Road Obstacle Signs EachSIiDDerv Road605 (1) af6 Warning Signs 600mm X 900 mm W5-9PB Road Obstacle Signs Each

SIiDDerv Road605 (1) afl Warning Signs 750mm X 1200 mm W5-9PC Road Obstacle Signs Each

SIiDDerv Road605 (1) ag1 Warning Signs 600 mm W5-10B Road Obstacle Signs Each

Animal Crossina605 (1) ag2 Warning Signs 750 mm W5-10C Road Obstacle Signs Each

Animal Crossino605 (1) ag3 Warning Signs 900 mm W5-10D Road Obstacle Signs Each

Animal Crossino605 (1) ah1 Warning Signs 450 mm W5-11A Road Obstacle Signs Each

Aircraft:605 (1) ah2 Warning Signs 600 mm W5-11B Road Obstacle Signs Each. Aircraft:605 (1) ah3 Warning Signs 750 mm W5-11C Road Obstacle Signs Each

Aircraft:605 (1) ah4 Warning Signs 900 mm W5-11D Road Obstacle Signs Each

Aircraft:

Page 30 VOL II

Page 34: Standardized Pay Items of Works for Civil Works Construction for

Pedestrian and School605 (1) ail Warning Signs 600mm X 600 mm W6-1B Signs Pedestrian Crossing Each

AheadPedestrian and School

605 (1) ai2 Warning Signs 750mm X 750 mm W6-1C Signs Pedestrian Crossing EachAhead

Pedestrian and School605 (1) ai3 Warning Signs 420mm X 675 mm W6-1P Signs Slow Down Each

Pedestrian Crossing Ahead

605 (1) ajl Warning Signs 600mm X 600 mm W6-2B Pedestrian and School EachSians Children Crossina

605 (1) aj2 Warning Signs 750mm X 750 mm W6-2C Pedestrian and School EachSians Children CrossinaPedestrian and School

605 (1) akl Warning Signs 300mm X 450 mm W6-3 Signs Cross Only At Ped EachXina

Pedestrian and School605 (1) all Warning Signs 450mm X 450 mm W6-4A Signs Wheel Chair Each

CrossinaPedestrian and School

605 (1) al2 Warning Signs 600mm X 600 mm W6-4B Signs Wheel Chair EachCrossina

Pedestrian and School605 (1) al3 Warning Signs 750mm X 750 mm W6-4C Signs Wheel Chair Each

Crosc:;ina

605 (1) aml Warning Signs 400mm X 900 mm W6-5A Pedestrian and School EachSians Bike Lane Ahead

605 (1) am2 Warning Signs 600mm X 900 mm W6-5B Pedestrian and School EachSians Bike Lane Ahead

Railroad CrossRailway Level Crossing

605 (1) anl Warning SignsPosition

W7-1 Signs Railroad Crossing EachPosition

Railway Level Crossing605 (1) aol Warning Signs 600 mm W7-2B Signs Railway Crossing Each

without sianalRailway Level Crossing

605 (1) ao2 Warning Signs 750 mm W7-2C Signs Railway Crossing Eachwithout sianal

Railway Level Crossing605 (1) ao3 Warning Signs 900 mm W7-2D Signs Railway Crossing Each

without sianalRailway Level Crossing

605 (1) apl Warning Signs 600 mm W7-3B Signs Railway Crossing Eachwith sianal

Page 31 VOL II

Page 35: Standardized Pay Items of Works for Civil Works Construction for

Railway Level Crossing605 (1) ap2 Warning Signs 750 mm W7-3C Signs Railway Crossing Each

with sianalRailway Level Crossing

605 (1) ap3 Warning Signs 900 mm W7-3D Signs Railway Crossing Eachwith sianal

Railway Level Crossing605 (1) aq1 Warning Signs 700mm X 900 mm W7-4 Signs Alternative Railway Each

Crossing Position

605 (1) ar1 Warning Signs 600mm X 400 mm W8-1ASupplementary Signs

EachAdvisorv Sneed

605 (1) ar2 Warning Signs 750mm X 500 mm W8-1BSupplementary Signs

EachAdvisorv SnPPrI

605 (1) ar3 Warning Signs 900mm X 600 mm W8-1CSupplementary Signs

EachAdvisorv SnPed

605 (1) as1 Warning Signs 600mm X 400 mm W8- 2ASupplementary Signs On

EachSide Road

605 (1) as2 Warning Signs 750mm X 500 mm W8-2BSupplementary Signs On

EachSide Road

605 (1) as3 Warning Signs 900mm X 600 mm W8-2CSupplementary Signs On

EachSide Road

605 (1) aU Warning Signs 600mm X 200 mm W8- 3ASupplementary Signs

EachDistance ... m

605 (1) at2 Warning Signs 750mm X 250 mm W8-3BSupplementary Signs

EachDistance ... m

605 (1) at3 Warning Signs 900mm X 300 mm W8- 3CSupplementary Signs

EachDistance ... m

605 (1) au1 Warning Signs 600mm X 200 mm W8-4ASupplementary Signs

EachDistance ... km

605 (1) au2 Warning Signs 750mm X 250 mm W8-4BSupplementary Signs

EachDistance ... km

605 (1) au3 Warning Signs 900mm X 300 mm W8-4CSupplementary Signs

EachDistance ... km

605 (1) av1 Warning Signs 600mm X 400 mm W8-5ASupplementary Signs

EachWhen Wet

605 (1) av2 Warning Signs 750mm X 500 mm W8-5BSupplementary Signs

EachWhen Wet

605 (1) av3 Warning Signs 900mm X 600 mm W8-5CSupplementary Signs Each

When Wet

605 (1) awl Warning Signs 600mm X 200 mm W8-6A Supplementary Signs Blind Each

605 (1) aw2 Warning Signs 750mm X 250 mm W8-6B Supplementary Signs Blind Each

605 (1) aw3 Warning Signs 900mm X 300 mm W8-6C Supplementary Signs Blind Each,...,.... ",.-,-,~.. ""'--.~'.

Page 32 VOL II

Page 36: Standardized Pay Items of Works for Civil Works Construction for

605 (1) axl Warning Signs 600mm X 200 mm W8-7A Supplementary Signs Aged Each

605 (1) ax2 Warning Signs 750mm X 250 mm W8-7B Supplementary Signs Aged Each

605 (1) ax3 Warning Signs 900mm X 300 mm W8-7C Supplementary Signs Aged Each

605 (1) ayl Warning Signs 600mm X 400 mm W8-8ASupplementary Signs

EachPlavaround

605 (1) ay2 Warning Signs 750mm X 500 mm W8-8BSupplementary Signs

EachPlavaround

605 (1) ay3 Warning Signs 900mm X 600 mm W8-8CSupplementary Signs

EachPlavaround

605 (1) azl Warning Signs 600mm X 200 mm W8-9ASupplementary Signs

EachSchool

605 (1) az2 Warning Signs 750mm X 250 mm W8-9BSupplementary Signs

EachSchool

605 (1) az3 Warning Signs 900mm X 300 mm W8-9CSupplementary Signs

EachSchool

605 (1) bal Warning Signs 600mm X 200 mm W8-10ASupplementary Signs

EachDisabled

605 (1) ba2 Warning Signs 750mm X 250 mm W8-10BSupplementary Signs

EachDisabled

605 (1) ba3 Warning Signs 900mm X 300 mm W8-10CSupplementary Signs

EachDisabled

Otherr Warning Signs605 (1) bbl Warning Signs 1500mm X 600 mm W9-1A Vertical Clearance; Each

CLEARANCEOther Warning Signs

605 (1) bb2 Warning Signs 1950mm X 600 mm W9-1B Vertical Clearance; LOW EachCLEARANCE

605 (1) bb3 Warning Signs 1060mm X 600 mm W9-2AOther Warning Signs Slow

EachDown Accident Prone Area

Other Warning Signs605 (1) bb4 Warning Signs 1060mm X 600 mm W9-2B Bumagal Madalas Ang Each

Aksidente DitoOther Warning Signs Slow

605 (1) bb5 Warning Signs 1060mm X 600 mm W9-3 Down Merging Traffic EachAhead

605 (1) bb6 Warning Signs 950mm X 600 mm W9-4Other Warning Signs Lane

EachEnds - Merae Left

605 (1) bb7 Warning Signs 1060mm X 600 mm W9-5Other Warning Signs Slow

EachDown Weighbridge Ahead

605 (2) al Reaulatorv Sians 450 x 450 mm Rl-1A Priority Sians StOD Each605(2) a2 Reaulatorv Sians 600 x 600 mm Rl-1B Priority Sians StOD Each

Page 33 VOL II

Page 37: Standardized Pay Items of Works for Civil Works Construction for

605 2 a3 Re(]ulatorv Siclns"" ~.. ~"-'-c.........~~__

750 x 750 mm R1-1C Priority Sians Stoo Each605 2 a4 Reaulatorv Sians 900 x 900 mm R1-lD Priority Sians Stoo Each605 2 b1 Reaulatorv Sians 600 mm Rl-2A Priority Sians Give Wav Each605 2 b2 Reaulatorv Sians 750 mm Rl-2B Priority Sians Give Wav Each605 2 b3 Reaulatorv Sians 900 mm Rl-2C Priority Sians Give Wav Each605 2 b4 Reaulatorv Sians 640 x 900 mm R1-2P Priority Sians Give Wav Each

605 (2) c1 Regulatory Signs 500 x 750 mm Rl-3Priority Signs Left Turner Each

Must Give Wav

605 (2) d1 Regulatory Signs 450 mm R2-1ADirection Signs NO TURNS; Each

Disc Tvoe

605 (2) d2 Regulatory Signs 450 mm R2-2ADirection Signs ONE WAY; Each

Disc Tvoe

605 (2) d3 Regulatory Signs 450 mm R2-3ADirection Signs KEEP Each

RIGHT' Disc Tvoe

605 (2) d4 Regulatory Signs 450 mm R2-4ADirection Signs LANE Each

SPLIT' Disc Tvoe

605 (2) d5 Regulatory Signs 450 mm R2-5ADirection Signs ALL Each

TRAFFIC' Disc Tvoe

605 (2) d6 Regulatory Signs 450 mm R2-6ADirection Signs MERGING Each

TRAFFIC; Disc Type

605 (2) d7 Regulatory Signs 450 mm R2-7ADirection Signs TWO WAY; Each

Disc Tvoe

605 (2) e1 Regulatory Signs 600 mm R2-1BDirection Signs NO TURNS; Each

Disc Tvoe

605 (2) e2 Regulatory Signs 600 mm R2-2BDirection Signs ONE WAY; Each

Disc Tvoe

605 (2) e3 Regulatory Signs 600 mm R2-3BDirection Signs KEEP Each

RIGHT' Disc Tvoe

605 (2) e4 Regulatory Signs 600 mm R2-4BDirection Signs LANE Each

SPLIT' Disc Tvoe

605 (2) e5 Regulatory Signs 600 mm R2-5BDirection Signs ALL Each

TRAFFIC: Disc Tvoe

605 (2) e6 Regulatory Signs 600 mm R2-6BDirection Signs MERGING Each

TRAFFIC; Disc Type

605 (2) e7 Regulatory Signs 600 mm R2-7BDirection Signs TWO WAY; Each

Disc Tvoe

605 (2) f1 Regulatory Signs 750 mm R2-1CDirection Signs NO TURNS; Each

Disc Tvoe

605 (2) f2 Regulatory Signs 750 mm R2-2CDirection Signs ONE WAY; Each

Disc Tvne

605 (2) f3 Regulatory Signs 750 mm R2-3CDirection Signs KEEP Each

RIGHT' Disc Tvoe

605 (2) f4 Regulatory Signs 750 mm R2-4CDirection Signs LANE Each

SPLIT' Disc Tvoe

Page 34 VOL II

Page 38: Standardized Pay Items of Works for Civil Works Construction for

605 (2) fS Regulatory Signs 750 mm R2-5C Direction Signs ALLEach

TRAFFIC' Disc Tvoe

605 (2) f6 Regulatory Signs 750 mm R2-GC Direction Signs MERGINGEachTRAFFIC; Disc Type

605 (2) f7 Regulatory Signs 750 mm R2-7C Direction Signs TWO WAY;EachDisc Tvoe

605 (2) g1 Regulatory Signs Disc Size 400 mm R2-1PA Direction Signs NO TURNS;EachPlate Type; 450 x 750 mm

605 (2) g2 Regulatory Signs Disc Size 400 mm R2-2PA Direction Signs ONE WAY;EachPlate Type; 450 x 750 mm

Direction Signs KEEP605 (2) g3 Regulatory Signs Disc Size 400 mm R2-3PA RIGHT; Plate Type; 450 x Each

750 mmDirection Signs ALL

605 (2) g4 Regulatory Signs Disc Size 400 mm R2-5PA TRAFFIC; Plate Type; 450 Eachx 750 mm

Direction Signs MERGING605 (2) g5 Regulatory Signs Disc Size 400 mm R2-6PA TRAFFIC; Plate Type; 450 Each

x 750 mm

605 (2) h1 Regulatory Signs 450 x 750 mm R2-7PA Other Directional SignsEachTWO WAY

605 (2) h2 Regulatory Signs 900 x 700 mm R2-7S Other Directional SignsEachSALUBONG NA TRAPIKO

Other Directional Signs605 (2) h3 Regulatory Signs 450 X 750 mm R2-8A (R) RIGHT LANE MUST TURN Each

RIGHTOther Directional Signs

605 (2) h4 Regulatory Signs 450 X 750 mm R2-8A (L) LEFT LANE MUST TURN EachLEFT

Other Directional Signs605 (2) h5 Regulatory Signs 600 X 1000 mm R2-8B (R) RIGHT LANE MUST TURN Each

RIGHTOther Directional Signs

605 (2) h6 Regulatory Signs 600 X 1000 mm R2-8B (L) LEFT LANE MUST TURN EachLEFT

Prohibitive or Restrictive605 (2) i1 Regulatory Signs 600 mm R3-1A Signs No Entry for All Each

VehiclesProhibitive or Restrictive

605 (2) i2 Regulatory Signs 750 mm R3-1B Signs No Entry for All EachVehicles

Page 35 VOL II

Page 39: Standardized Pay Items of Works for Civil Works Construction for

Prohibitive or Restrictive605 (2) i3 Regulatory Signs 400 x 600 mm R3-1PA Signs No Entry for All Each

VehiclesProhibitive or Restrictive

605 (2) i4 Regulatory Signs 600 x 900 mm R3-1 PB Signs No Entry for All EachVehicles

Prohibitive or Restrictive605 (2) is Regulatory Signs 800 x 1200 mm R3-1PC Signs No Entry for All Each

Vehicles

605 (2) j1 Regulatory Signs 450 mm R3-2AProhibitive or Restrictive EachSigns No Entry for Cars

Prohibitive or Restrictive605 (2) j2 Regulatory Signs 450 mm R3-3A Signs No Entry for Each

Jeennevs

605 (2) j3 Regulatory Signs 450 mm R3-4AProhibitive or Restrictive Each

Signs No Entry for Bicycles

Prohibitive or Restrictive605 (2) j4 Regulatory Signs 450 mm R3-5A Signs No Entry for Each

MotorrvclesProhibitive or Restrictive

605 (2) j5 Regulatory Signs 450 mm R3-6A Signs No Entry for EachTrirvcles

605 (2) j6 Regulatory Signs 450 mm R3-7AProhibitive or Restrictive EachSigns No Entry for Buses

605 (2) j7 Regulatory Signs 450 mm R3-8AProhibitive or Restrictive Each

Signs No Entry for Trucks

Prohibitive or Restrictive605 (2) j8 Regulatory Signs 450 mm R3-9A Signs No Entry for Trucks Each

with Trailer

Prohibitive or Restrictive605 (2) j9 Regulatory Signs 450 mm R3-10A Signs No Entry for Each

Pedestrians

Prohibitive or Restrictive605 (2) j10 Regulatory Signs 450 mm R3-llA Signs No Entry for Animal Each

Drawn Vehicle

Prohibitive or Restrictive605 (2) jll Regulatory Signs 450 mm R3-12A Signs No Entry for Each

PII~hcarts

Page 36 VOLII

Page 40: Standardized Pay Items of Works for Civil Works Construction for

,

605 (2) k1 Regulatory Signs 600 mm R3-2BProhibitive or Restrictive

EachSigns No Entry for Cars

Prohibitive or Restrictive605 (2) k2 Regulatory Signs 600 mm R3-3B Signs No Entry for Each

Jeeonevs

605 (2) k3 Regulatory Signs 600 mm R3-4BProhibitive or Restrictive

EachSigns No Entry for Bicycles

Prohibitive or Restrictive605 (2) k4 Regulatory Signs 600 mm R3-5B Signs No Entry for Each

MotorcvclesProhibitive or Restrictive

605 (2) k5 Regulatory Signs 600 mm R3-6B Signs No Entry for EachTricvcles

605 (2) k6 Regulatory Signs 600 mm R3-7BProhibitive or Restrictive

EachSigns No Entry for Buses

605 (2) k7 Regulatory Signs 600 mm R3-8BProhibitive or Restrictive

EachSigns No Entry for Trucks

Prohibitive or Restrictive605 (2) k8 Regulatory Signs 600 mm R3-9B Signs No Entry for Trucks Each

with Trailer

Prohibitive or Restrictive605 (2) k9 Regulatory Signs 600 mm R3-10B Signs No Entry for Each

Pedestrians

Prohibitive or Restrictive605 (2) k10 Regulatory Signs 600 mm R3-11B Signs No Entry for Animal Each

Drawn Vehicle

Prohibitive or Restrictive605 (2) kll Regulatory Signs 600 mm R3-12B Signs No Entry for Each

plJc;hr~rts

605 (2) 11 Regulatory Signs 750 mm R3-2C. Prohibitive or Restrictive

EachSigns No Entry for Cars

Prohibitive or Restrictive605 (2) 12 Regulatory Signs 750 mm R3-3C Signs No Entry for Each

Jeeonevs

605 (2) 13 Regulatory Signs 750 mm R3-4CProhibitive or Restrictive

EachSigns No Entry for Bicycles

Page 37 VOL II

Page 41: Standardized Pay Items of Works for Civil Works Construction for

-"'-'~-~--''''''''-'-'

Prohibitive or Restrictive605 (2) 14 Regulatory Signs 750 mm R3-5C Signs No Entry for Each

MotorcvclesProhibitive or Restrictive

605 (2) 15 Regulatory Signs 750 mm R3-6C Signs No Entry for EachTrirvcles

605 (2) 16 Regulatory Signs 750 mm R3-7CProhibitive or Restrictive

EachSigns No Entry for Buses

605 (2) 17 Regulatory Signs 750 mm R3-8CProhibitive or Restrictive

EachSigns No Entry for Trucks

Prohibitive or Restrictive605 (2) 18 Regulatory Signs 750 mm R3-9C Signs No Entry for Trucks Each

with Trailer

Prohibitive or Restrictive605 (2) 19 Regulatory Signs 750 mm R3-10C Signs No Entry for Each

Pedestrians

Prohibitive or Restrictive605 (2) 110 Regulatory Signs 750 mm R3-11C Signs No Entry for Animal Each

Drawn Vehicle

Prohibitive or Restrictive605 (2) 111 Regulatory Signs 750 mm R3-12C Signs No Entry for Each

Pushcarts

605 (2) m1 Regulatory Signs 450 x 600 mm R3-10P1Prohibitive or Restrictive Each

Signs Use Overpass

605 (2) m2 Regulatory Signs 450 X 600 mm R3-10P2Prohibitive or Restrictive

EachSigns Use Pedxing

Prohibitive or Restrictive605 (2) m3 Regulatory Signs 300 X 350 mm R3-10P3 Signs Bawal tumawid Each

gamitin ang Overpass

Prohibitive or Restrictive605 (2) n1 Regulatory Signs 600 mm R3-13A Signs Turning Prohibition; Each

No Right Turn

Prohibitive or Restrictive605 (2) n2 Regulatory Signs 900 mm R3-13B Signs Turning Prohibition; Each

No Right Turn

Page 38 VOL II

Page 42: Standardized Pay Items of Works for Civil Works Construction for

Prohibitive or Restrictive605 (2) n3 Regulatory Signs 450 x 750 mm R3-13 PA Signs Turning Prohibition; Each

No Right Turn

Prohibitive or Restrictive605 (2) n4 Regulatory Signs 600 x 1000 mm R3-13 PB Signs Turning Prohibition; Each

No Right Turn

Prohibitive or Restrictive605 (2) 01 Regulatory Signs 600 mm R3-14A Signs Turning Prohibition; Each

No Left Turn

Prohibitive or Restrictive605 (2) 02 Regulatory Signs 900 mm R3-14B Signs Turning Prohibition; Each

No Left Turn

Prohibitive or Restrictive605 (2) 03 Regulatory Signs 450 x 750 mm R3-14 PA Signs Turning Prohibition; Each

No Left Turn

Prohibitive or Restrictive605 (2) 04 Regulatory Signs 600 x 1000 mm R3-14 PB Signs Turning Prohibition; Each

No Left Turn

Prohibitive or Restrictive605 (2) p1 Regulatory Signs 600 mm R3-15A Signs Turning Prohibition; Each

No U Turn

Prohibitive or Restrictive605 (2) p2 Regulatory Signs 900 mm R3-15B Signs Turning Prohibition; Each

No U Turn

Prohibitive or Restrictive605 (2) p3 Regulatory Signs 450 x 750 mm R3-15 PA Signs Turning Prohibition; Each

No U Turn

Prohibitive or Restrictive605 (2) p4 Regulatory Signs 600 x 1000 mm R3-15 PB Signs Turning Prohibition; Each

No U Turn

Prohibitive or Restrictive605 (2) q1 Regulatory Signs 600 mm R3-16A Signs Prohibition of Each

Overtaking

Page 39 VOL II

Page 43: Standardized Pay Items of Works for Civil Works Construction for

Prohibitive or Restrictive605 (2) q2 Regulatory Signs 900 mm R3-16B Signs Prohibition of Each

Overtaking

Prohibitive or Restrictive

605 (2) q3 Regulatory Signs 600 x 900 mm R3-16 PASigns Prohibition of

EachOvertaking; Bawal

Lumusot

Prohibitive or Restrictive

605 (2) q4 Regulatory Signs 750 x 1000 mm R3-16 PBSigns Prohibition of

EachOvertaking; Bawal

Lumusot

605 (2) r1 Regulatory Signs 450 mm R4-1ASpeed Signs Speed

EachRestriction (Maximum)

605 (2) r2 Regulatory Signs 600 mm R4-1BSpeed Signs Speed

EachRestriction (Maximum)

605 (2) r3 Regulatory Signs 900 mm R4-1CSpeed Signs Speed

EachRestriction (Maximum)

605 (2) r4 Regulatory Signs 900 mm R4-2ASpeed Signs Speed

EachRestriction (Minimum)

605 (2) sl Regulatory Signs 450 x 450 mm R4-2BSpeed Signs Speed De-

Eachrestriction Sians

605 (2) s2 Regulatory Signs 600 x 600 mm R4-2PASpeed Signs Speed De-

Eachrestriction Sians

605 (2) s3 Regulatory Signs 450 x 750 mm R4-2PBSpeed Signs Speed De- Each

restriction Sians

605 (2) s4 Regulatory Signs 600 x 1000 mm R4-2PCSpeed Signs Speed De-

Eachrestriction Sians

605 (2) s5 Regulatory Signs 800 x 1334 mm R4-3ASpeed Signs Speed De-

Eachrestriction Sians

605 (2) t1 Regulatory Signs 450 mm R5-1SAParking Signs No Parking

Each(Disc)

605 (2) t2 Regulatory Signs 600 mm R5-1SBParking Signs No Parking

Each(Disc)

605 (2) u1 Regulatory Signs 450 x 750 mm R5-1PAParking Signs No Parking

Each(Pilipino Worded) (Plate)

605 (2) u2 Regulatory Signs 600 x 1000 mm R5-1PCParking Signs No Parking Each(Pilipino Worded) (Plate)

605 (2) v1 Regulatory Signs 450 x 750 mm R5-2PAParking Signs No Parking -

EachLoading Only (Plate)

Page 40 VOL II

Page 44: Standardized Pay Items of Works for Civil Works Construction for

605 (2) v2 Regulatory Signs 600 x 1000 mm R5-2PB Parking Signs No Parking - EachLoading Only (Plate)

605 (2) wl Regulatory Signs 450 x 750 mm R5-3PA Parking Signs No Parking - EachAnytime (Plate)

605 (2) w2 Regulatory Signs 600 x 1000 mm R5-3PB Parking Signs No Parking - EachAnytime (Plate)

605 (2) xl Regulatory Signs 450 x 750 mm R5-3CA Parking Signs No Parking - EachTow Away (Plate)

605 (2) x2 Regulatory Signs 600 x 1000 mm R5-3CBParking Signs No Parking - Each

Tow Away (Plate)

605 (2) yl Regulatory Signs 450 x 750 mm R5-4 Parking Signs Restricted EachParkina: Meter Parkina

605 (2) y2 Regulatory Signs 450 x 750 mm R5-4A Parking Signs Restricted EachParkina: 2 Hour Parkina

605 (2) zl Regulatory Signs 450 x 750 mm R5-4B Parking Signs Loading EachSians· Loadina Zone

Parking Signs Loading605 (2) z2 Regulatory Signs 450 x 750 mm R5-4C Signs; Loading and Each

Unloadina Zone

605 (2) aa1 Regulatory Signs 450 x 750 mm R5-5 Parking Signs No Waiting EachSians

605 (2) aa2 Regulatory Signs 450 x 750 mm R5-5A Parking Signs No Waiting EachSians

605 (2) aa3 Regulatory Signs 450 x 750 mm R5-5B Parking Signs No Waiting EachSians

605 (2) ab1 Regulatory Signs 450 x 750 mm R5-6 Parking Signs No Loading Eachand Unloading Signs

605 (2) ab2 Regulatory Signs 450 x 750 mm R5-6A Parking Signs No Loading Eachand Unloading Signs

Parking Signs No605 (2) ab3 Regulatory Signs 450 x 750 mm R5-7 Loading/Unloading Within Each

Red-Painted Curb

605 (2) ac1 Regulatory Signs 450 x 750 mm R5-8Parking Signs No Stopping Each

AnvtimeParking Signs No Parking

605 (2) ac2 Regulatory Signs 400 x 900 mm R5-9A or Stopping Signs; BUS EachSton

Page 41 VOLII

Page 45: Standardized Pay Items of Works for Civil Works Construction for

Parking Signs No Parking605 (2) ac3 Regulatory Signs 400 x 900 mm R5-9B or Stopping Signs; PUJ Each

StonParking Signs No Parking

605 (2) ac4 Regulatory Signs 400 x 900 mm R5-9C or Stopping Signs; Bus-PUJ EachStnn

605 (2) adl Regulatory Signs 400 x 600 mm R5-l0Parking Signs Do Not Each

Block IntersectionParking Signs Right

605 (2) ael Regulatory Signs 450 x 600 mm R5-11 Turners Cross at Broken EachWhite Lines

Miscellaneous Signs605 (2) afl Regulatory Signs 600 mm R6-l Prohibition on Use of Each

Audible Warn inn r1PvirpMiscellaneous Signs Load

605 (2) agl Regulatory Signs 600 mm R6-2 and Dimension Restriction EachSians

Miscellaneous Signs Load605 (2) ag2 Regulatory Signs 600 mm R6-3 and Dimension Restriction Each

SiansMiscellaneous Signs Load

605 (2) ag3 Regulatory Signs 600 mm R6-4 and Dimension Restriction EachSians

Miscellaneous Signs Load605 (2) ag4 Regulatory Signs 600 mm R6-5 and Dimension Restriction Each

SiansMiscellaneous Signs Load

605 (2) ag5 Regulatory Signs 600 mm R6-6 and Dimension Restriction EachSjnnc;

605 (2) ahl Regulatory Signs 450 x 675 mm R6-7 Miscellaneous Signs Use EachSeat Belt Sinn

605 (2) ail Regulatory Signs 450 mm R6-8A Miscellaneous Signs EachPedestrian Crossina

605 (2) ai2 Regulatory Signs 600 mm R6-8B Miscellaneous Signs EachPedestrian Crossina

605 (2) ai3 Regulatory Signs 750 mm R6-8C Miscellaneous Signs EachPedestrian Crossina

605 (2) ajl Regulatory Signs 450 mm R6-9A Miscellaneous Signs School EachChildren Crossing

605 (2) aj2 Regulatory Signs 600 mm R6-9B Miscellaneous Signs EachSchool Children Crossing

605 (2) aj3 Regulatory Signs 750 mm R6-9CMiscellaneous Signs Each

School Children Crossing

Page 42 VOL II

Page 46: Standardized Pay Items of Works for Civil Works Construction for

605 (2) akl Regulatory Signs 450 mm R6-10AMiscellaneous Signs Bike

EachLane Sians

605 (2) ak2 Regulatory Signs 600 mm R6-10BMiscellaneous Signs Bike

EachLane Sians

605 (2) ak3 Regulatory Signs 750 mm R6-10CMiscellaneous Signs Bike

EachLane Sians

Miscellaneous Signs605 (2) all Regulatory Signs 450 mm R6-11A Wheel Chair Crossing Each

SiansMiscellaneous Signs

605 (2) al2 Regulatory Signs 600 mm R6-11B Wheel Chair Crossing EachSians

Miscellaneous Signs605 (2) al3 Regulatory Signs 750 mm R6-11C Wheel Chair Crossing Each

C:;ianc;

605 (3) al Guide or Information Signs Gl-lAdvance Direction Signs

EachStack Sians

605 (3) a2 Guide or Information Signs Gl-2Advance Direction Signs

EachStack Sians

605 (3) a3 Guide or Information Signs Gl-3Advance Direction Signs

EachStack Sians

Advance Direction Signs605 (3) bl Guide or Information Signs Gl-4 Diagrammatic Direction Each

SiansAdvance Direction Signs

605 (3) b2 Guide or Information Signs Gl-5 Diagrammatic Direction EachSians

605 (3) cl Guide or Information Signs G2-1Intersection Direction

EachSians

605 (3) c2 Guide or Information Signs G2-2Intersection Direction

EachSians

605 (3) c3 Guide or Information Signs G2-3Intersection Direction

EachSians

605 (3) c4 Guide or Information Signs G2-4Intersection Direction

EachSians

605 (3) dl Guide or Information Signs G3-1Reassurance Direction

EachSians

605 (3) d2 Guide or Information Signs G3-2Reassurance Direction

EachSians

605 (3) el Guide or Information Signs G4-1Finger Board Direction

EachSians

605 (3) e2 Guide or Information Signs G4-2Finger Board Direction

EachSians

605 (3) e3 Guide or Information Signs G4-3Finger Board Direction

EachSians

605 (3) f1 Guide or Information Sians G5-1 Street Name Sians Each

Page 43 VOL II

Page 47: Standardized Pay Items of Works for Civil Works Construction for

605 3 f2 Guide or Information Siqns"'~'_"~ ..,.,.,.""",-.-..-._ "=-..,,,,-0,"""''''''''-'-='''''''''''''''''-'=_. _. _,,~

EachGS-2A Street Name Siqns605 3 f3 Guide or Information Siqns GS-2B Street Name Siqns Each605 3 f4 Guide or Information Siqns GS-3 Street Name Siqns Each

Town Name and605 (3) gl Guide or Information Signs G6-1 Geographical Feature Each

Siqns Town NameTown Name and

605 (3) g2 Guide or Information Signs G6-2 Geographical Feature EachSiqns Province Name

Town Name and605 (3) g3 Guide or Information Signs G6-3 Geographical Feature Each

Signs Geographic Feature

Town Name and

605 (3) g4 Guide or Information Signs G6-4Geographical Feature

EachSigns Local Government

605 (3) h1 Guide or Information Signs G7-1Service Signs Service Each

Center 2km

605 (3) h2 Guide or Information Signs G7-2Service Signs Weigh bridge Each

Station

605 (3) h3 Guide or Information Signs G7-3Service Signs Parking and Each

RestroomsService Signs Gasoline

605 (3) h4 Guide or Information Signs G7-3A Station and Restaurant or EachCafes

Service Signs Rest Area605 (3) hS Guide or Information Signs G7-4 and Truck Parking Turn Each

Left 300m

605 (3) h6 Guide or Information Signs G7-SService Signs Shopping Each

Center

605 (3) i1 Guide or Information Signs G8-1Tourist Information and EachTourist Destination Signs

605 (3) i2 Guide or Information Signs G8-2Tourist Information and EachTourist Destination Signs

605 (3) i3 Guide or Information Signs G8-3Tourist Information and Each

Tourist Destination Signs

605 (3) i4 Guide or Information Signs G8-4Tourist Information and EachTourist Destination Signs

605 (3) j1 Guide or Information Signs G9-1Route Markers Route Each

Number605 (3) i2 Guide or Information Siqns G9-2 Route Markers Each

Page 44 VOl"

Page 48: Standardized Pay Items of Works for Civil Works Construction for

605 3 13 Guide or Information Siems G9-3 Route Markers Each605 3 i4 Guide or Information Sians G9-4 Route Markers Each605 3 is Guide or Information Sians G9-S Route Markers Each605 3 i6 Guide or Information Sians G9-6 Route Markers Each605 3 17 Guide or Information Sians G9-7 Route Markers END Each605 3 i8 Guide or Information Sians G9-8 Route Markers Each

605 (3) k1 Guide or Information Signs 600mm X 750 mm G10-1A Asian Highway Route EachMarkers

605 (3) k2 Guide or Information Signs 900 mm G10-1BAsian Highway Route Each

Markers

605 (4) a1 Signs on Expressways GE1-1 Expressway Approach EachSians

605 (4) a2 Signs on Expressways GEl-2 Expressway Approach EachSians

605 (4) a3 Signs on Expressways GEl-3Expressway Approach Each

SiansExpressway Information

605 (4) b1 Signs on Expressways GE2-1A Signs Prohibited on EachExoresswav

Expressway Information605 (4) b2 Signs on Expressways GE2-1B Signs Prohibited on Each

ExnresswavExpressway Information

605 (4) b3 Signs on Expressways GE2-1C Signs Prohibited on EachExorpc;c;w;lV

Expressway Information605 (4) b4 Signs on Expressways GE2-2 Signs Toll Charges Each

(Advance Information)

605 (4) bS Signs on Expressways GE2-3 Expressway Information EachSigns Lane Direction Signs

605 (4) c1 Signs on Expressways GE3-1 Advance Exit Signs EachAdvance Exit with distance

Advance Exit Signs605 (4) c2 Signs on Expressways GE3-2 Advance Exit with Distance Each

plus RIGHT LANE

Advance Exit Signs605 (4) c3 Signs on Expressways GE3-3 Supplementary Advance Each

(NEXT EXIT)Expressway Exit Direction

605 (4) d1 Signs on Expressways GE4-1 Signs Exit signs with EachDestination

Page 45 VOL II

Page 49: Standardized Pay Items of Works for Civil Works Construction for

605 (4) d2 Signs on Expressways GE4-2 Expressway Exit Direction EachSigns NEXT EXIT..... KM

605 (4) d3 Signs on Expressways GE4-3 Expressway Exit Direction EachSians EXIT

605 (4) d4 Signs on Expressways GE4-3A Expressway Exit Direction EachSigns Numbered exit

605 (4) el Signs on Expressways 2800mm X 1500 GE5-1 Expressway Service Signsmm Rest Area Right Lane 2km

Each

605 (4) e2 Signs on Expressways 2800mm X 1500 GE5-1A Expressway Service Signsmm Rest Area Right Lane 2km

Each

605 (4) e3 Signs on Expressways 2500mm X 1100 GE5-2 Expressway Service Signsmm Rest Area 2km

Each

605 (4) e4 Signs on Expressways 1500mm X 1800 GE5-3 Expressway Service Signsmm Rest Area

Each

605 (4) e5 Signs on Expressways 2800mm X 1500 GE5-4 Expressway Service Signsmm Service Center 2km

Each

605 (4) e6 Signs on Expressways 2240mm X 1800 GE5-5 Expressway Service Signsmm Truck Parking 2km

Each

605 (4) e7 Signs on Expressways 3240mm X 1800 GE5-6 Expressway Service Signsmm Restaurant Next Exit

Each

605 (4) e8 Signs on Expressways 2800mm X 1800 GE5-7 Expressway Service Signsmm Truck Parkina exit

Each

605 (4) fl Signs on Expressways 2300mm X 1500 GE6-1 End of Expressway ENDmm EXPRWAY 1 Km

Each

605 (4) f2 Signs on Expressways 1200mm X 600 mm GE6-1A End of Expressway END EachEXPRWAY 2 Km

605 (4) f3 Signs on Expressways 900mm X 450 mm GE6-2 End of Expressway START EachEXPRWAY

605 (4) f4 Signs on Expressways 900mm X 450 mm GE6-3 End of Expressway END EachEXPRWAY

605 (4) gl Signs on Expressways 2600mm X 1600 GE7-1 Toll Signs Toll Plaza Aheadmm

Each

605 (4) g2 Signs on Expressways 1600mm X 1900 GE7-2 Toll Signs Stop At Tollmm Gates

Each

605 (4) g3 Signs on Expressways 2400mm X 1200 GE7-3 Toll Signs Pay Toll Aheadmm

Each

Page 46 VOL II

Page 50: Standardized Pay Items of Works for Civil Works Construction for

Expressway Traffic

605 (4) h1 Signs on Expressways2300mm X 1470

GE8-1Instruction and Regulatory

Eachmm Signs Wrong Way - Go

BackExpressway Traffic

605 (4) h2 Signs on Expressways1600mm X 1700

GE8-2Instruction and Regulatory

Eachmm Signs Right Lane Ends

.mExpressway Traffic

605 (4) h3 Signs on Expressways2700mm X 1700

GE8-3Instruction and Regulatory

Eachmm Signs Right Lanes Ends

Merae LeftExpressway Traffic

605 (4) h4 Signs on Expressways2700mm X 1400

GE8-4Instruction and Regulatory

Eachmm Signs Lane Ends Merge

I~ft

1750mm X 1500Expressway Traffic

605 (4) h5 Signs on Expressways GE8-5 Instruction and Regulatory Eachmm

Signs Merge Left

Expressway Traffic

605 (4) h6 Signs on Expressways2400mm X 2950

GE8-6Instruction and Regulatory

Eachmm Signs Slow Vehicle Use

Riaht Lane

2000mm X 1100Expressway Traffic

605 (4) h7 Signs on Expressways GE8-7 Instruction and Regulatory Eachmm Signs Check Brakes

2600mm X 2000Expressway Traffic

605 (4) i1 Signs on Expressways Sl-4E Instruction and Regulatory Eachmm Signs Reduced Speed Now

Expressway Traffic605 (4) j1 Signs on Expressways 900 Disc R4-1C (XXX) Instruction and Regulatory Each

Signs Speed Limit Sign

Expressway Traffic605 (4) j2 Signs on Expressways 1200 Disc R4-lD (XXX) Instruction and Regulatory Each

Signs Speed Limit Sign

Expressway Traffic

605 (4) k1 Signs on Expressways 900 Disc R4-3A (XX)Instruction and Regulatory

EachSigns Minimum Speed

Limit

Page 47 VOL II

Page 51: Standardized Pay Items of Works for Civil Works Construction for

Expressway Traffic

605 (4) k2 Signs on Expressways 1200 Disc R4-3B (XX)Instruction and Regulatory

EachSigns Minimum Speed

LimitExpressway Traffic

605 (4) 11 Signs on Expressways 900 Disc R4-2CInstruction and Regulatory

EachSigns Speed De-

. "

Expressway Traffic

605 (4) 12 Signs on Expressways 1200 Disc R4-2DInstruction" and Regulatory

EachSigns Speed De-

. "

605 (5) al Traffic Instruction Signs 600mm X 300 mm Sl-l Supplementary Signs USEEach

OVERPASS

605 (5) a2 Traffic Instruction Signs 600mm X 450 mm Sl-2 Supplementary Signs USEEach

PEDESTRIAN CROSSING

605 (5) a3 Traffic Instruction Signs 800mm X 600 mm Sl-3ASupplementary Signs

EachTRUCK USE LOW GEAR

605 (5) a4 Traffic Instruction Signs 1000mm X 750 mm Sl-3BSupplementary Signs

EachTRUCK USE LOW GEAR

605 (5) a5 Traffic Instruction Signs 620mm X 420 mm Sl-4Supplementary Signs

EachCHECK BRAKES

605 (5) bl Traffic Instruction Signs 1500mm X 750 mm S2-1Movement Instruction

EachSians REDUCE SPEEDMovement Instruction

605 (5) b2 Traffic Instruction Signs 450mm X 750 mm S2-2 Signs STOP HERE ON RED EachSIGNAL

Movement Instruction605 (5) b3 Traffic Instruction Signs 400mm X 600 mm S2-3L Signs TURN LEFT WITH Each

CAREMovement Instruction

605 (5) b4 Traffic Instruction Signs 750mm X 500 mm S2-3R Signs TURN RIGHT EachANYTIME WITH CARE

605 5 b5 Traffic Instruction Signs 1300mm X 350 mm S2-4A Movement Instruction Each605 5 b6 Traffic Instruction Signs 1400mm X 350 mm S2-4A(L)(R) Movement Instruction Each605 5 b7 Traffic Instruction Sians 900mm X 600 mm S2-5 Movement Instruction Each605 5 b8 Traffic Instruction Sians 500mm X 800 mm S2-6 Movement Instruction Each

Movement Instruction605 (5) b9 Traffic Instruction Signs 950mm X 1100 mm S2-7 Signs SLOW VEHICLES Each

USE RIGHT LANEMovement Instruction

605 (5) bl0 Traffic Instruction Signs S2-7ASigns MABAGAL NA

EachSASAKYAN MAMALAGI SA

I(ANAN

Page 48 VOL II

Page 52: Standardized Pay Items of Works for Civil Works Construction for

Movement Instruction

605 (5) b11 Traffic Instruction Signs S2-7B Signs TRAK AT BUSEach

MAMALAGI SA KANANMALUBAN KUNG LULUSOT

605 (5) b12 Traffic Instruction Signs 600mm X 400 mm S2-SA Movement InstructionEach

Signs NO THROUGH ROAD

605 5 b13 Traffic Instruction Sians 900mm X 600 mm S2-SB Movement Instruction Each605 5 b14 Traffic Instruction Sians 900mm X 550 mm S2-9 Movement Instruction Each605 5 b15 Traffic Instruction Sians 600mm X SOOmm S2-10 Movement Instruction Each605 5 b16 Traffic Instruction Sians 2100mm X 350 mm S2-11 Movement Instruction Each605 6 a Hazard Markers 1600mm X 400 mm HM 2 One-Wav Hazard Markers Each605 6 bl Hazard Markers lS00mm X 400 mm HM 3 Obstruction Marker Each605 6 cl Hazard Markers 2000mm X 400 mm HM4A Two-Wav Hazard Markers Each605 6 c2 Hazard Markers 1200mm X 400 mm HM4B Two-Wav Hazard Markers Each605 6 c3 Hazard Markers 400mm X 1000 mm HM 5 Two-Wav Hazard Markers Each605 6 dl Hazard Markers 225mm X 450 mm HM 6A Width Marker (L or R) Each605 6 d2 Hazard Markers 450mm X 900 mm HM 6B Width Marker (L or R) Each

ITEM 606 - PAVEMENT MARKINGSPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

606 1 a Pavement markinas Premixed White Square Meter606 1 b Pavement markinas Premixed Yellow Sauare Meter606 2 a Pavement markinas Retlectorized White Sauare Meter606 2 b Pavement markinas Retlectorized Yellow Sauare Meter

ITEM 607 - REFLECTIVE PAVEMENT STUDSPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

607 li) Retlectorized Pavement Studs Flush Type Each607 (2) Retlectorized Pavement Studs Raised Profile Tvoe Each

ITEM 608 - TOPSOILPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

60S (1) Furnishina and Placina Toosoil Cubic Meter60Sm Placina TODsoil Cubic Meter

ITEM 609 - SPRIGGINGPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

6091IT Soriaaina 100 Sauare Meter609 (2) SDriaaina Sauare Meter

Page 49 VOL II

Page 53: Standardized Pay Items of Works for Civil Works Construction for

ITEM 610 - SODDINGPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes I Class I Others

610 (1) Soddinq I I Sauare Meter

ITEM 611 - TREE PLANTINGPay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others611(1) Trees Furnishing and Transolantina Each611 (2) Trees Transolantina Each

ITEM 612 - REFLECTIVE THERMOPLASTIC STRIPING MATERIAL (SOLID FORM)Pay Item Suffix

Description Valid Values Unit Of Measure(Number) I (Subscri Thickness/Sizes Class Others612 1 Reflectorized Thermoolastic Pavement Markinas White Sauare Meter6122 Reflectorized Thermoplastic Pavement Markinas Yellow Square Meter6123 Removal of Existina Refelctorized Thermonlastic Pavement Markinas Sauare Meter

ITEM 613 - CONCRETEJOINT SEALANT (HOT -POURED ELASTIC AND COLD-APPLIED TYPES)Pay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others613 (1) Concrete Joint Sealant ( Hot-Poured Elastic Tvoe) Kiloaram613 (2) Concrete Joint Sealant ( Cold-Aoolied Tvoe) Kiloaram

ITEM 614 - WATERSTOPSPay Item Suffix

Description Valid Values Unit Of Measure(Numberl •(Subscri Thickness/Sizes Class Others614 1 a Waterstoo 100 mm. Meter614 1 b Waterstop 150 mm. Meter614 1 c Waterstoo 200 mm. Meter614 2 Waterstoo Lumo sum

ITEM 618 - REFLECTORIZED THERMOPLASTIC RUMBLE STRIPSPay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes I Class I Others618 (1) Reflectorized Thermoplastic Rumble Strios I I Sauare Meter

ITEM 620 - CHEVRON SIGNSPay Item Suffix

Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others620 (1) a Chevron Sians 450x600mm Each620 (1) b Chevron Siqns 600x800mm Each

Page 50 VOL II

Page 54: Standardized Pay Items of Works for Civil Works Construction for

ITEM 622 - COCONET BIO-ENGINEERING SOLUTIONSPay Item Suffix

Description Valid Values Unit Of Measure(Number\ (Subscri Thickness/Sizes Class Others622 1 a Coco-net CN 400 iauare Meter622 1 b Coco-net CN 700 iauare Meter622 1 c Coco-net CN 900 iauare Meter622 2 a Coco-laos Fascine CN 100 Linear Meter622 2 b Coco-laos Fascine CN 200 Linear Meter622 2 c Coco-laos Fascine CN 300 Linear Meter622 2 d Coco-laos Fascine CN 400 Linear Meter622 2 e Coco-laos Fascine CN 500 Linear Meter622 3 a Veoetation Grass-Cover Souare Meter622 3 b Veaetation Vetiver Grass System Sauare Meter

ITEM 623 - TRAFFIC SIGNAUZATION PROJECTSPay Item Suffix Description Valid Values Unit Of Measure(Number) (Subscri Thickness/Sizes Class Others

623 1 a1 Local Controller Footina TSC1 Unit623 1 a3 Footina TSC2 Tvoe A (w/oedestal) Unit623 1 a4 Footino TSC3 Tvoe A (w/o oedestal) Unit623 1 as Footina TSC4 Tvoe B Unit623 1 a6 Footino TSC5 Tvoe C Unit623 1 a7 Footina TSC5 Tvoe D Unit623 1 b1 Handhole TSC6 Tvoe B Unit623 1 b2 Handhole TSG Tvoe A Unit

623 (1) c1 Trenching - Double Barrel 100mm dia. TSC8P.E Pipe Concrete

Linear MeterPavement

623 (1) c2 Trenching - Single Barrel 100mm dia. TSC9P.E Pipe Concrete

Linear MeterPavement

623 (1) c3 Trenching - Double Barrel 100mm dia. TSC10P.E. Pipe on Asphalt

Linear MeterPavement

623 (1) c4 Trenching - Single Barrel 100mm dia. TSCllP.E. Pipe on Asphalt

Linear MeterPavement

623 (1) c5 Trenching - Double Barrel 100mm dia. TSC12P.E. Pipe on Concrete

Linear MeterSidewalk

623 (1) c6 Trenching - Single Barrel 100mm dia. TSC13P.E. Pipe on Concrete

Linear MeterSidewalk

623 (1) c7 Trenching - Double Barrel 100mm dia. TSC14 P.E. Pipe on Eath Surface Linear Meter

623 (1) c8 Trenching - Single Barrel 100mm dia. TSC15 P.E. Pipe on Eath Surface Linear Meter

623 1 d Concrete Bollard TSC16 Unit623 1 e Protection Caoe for Local Controller TSC17 Unit623 2 a1 Traffic Sianal Flasher Controller TSE1 Unit623 2 a2 Local Controller Microorocessor tvoe TSE2 8 Sianal Grouo Unit

Page Sl VOL II

Page 55: Standardized Pay Items of Works for Civil Works Construction for

623 2 a3 Local Controller Microorocessor tvoe TSE3 16 Sianal Grouo Unit623 2 a4 Local Controller Microorocessor tvoe TSE4 32 Sianal Grouo Unit623 2 b1 Detector Card/Board TSE5 8 Channel Unit623 2 b2 Detector Card/Board TSE6 16 Channel Unit623 2 c1 Traffic Sianal Head LED-tvoe 200mm 1 AsDect TSE7 Amber Lens Unit623 2 c2 Traffic Sianal Head LED-tvoe 200mm 1 Asoect TSE8 Red Lens Unit623 2 c3 Traffic Sienal Head LED-tvoe 200mm 1 AsDect TSE9 Green Lens Unit623 2 c4 Traffic Sianal Head LED-:voe 200mm 2 AsDect TSE10 Set623 2 c5 Traffic Sienal Head. LED- tvoe 200mm 3 Asoect TSEll Set623 2 c6 Traffic Sianal Head LED- tvoe 200mm 4 Asoect TSE12 Set623 2 c7 Traffic Sianal Head. LED-tvoe 200mm 5 Asoect TSE13 Set623 2 c8 Traffic Siena I Head. LED-tvoe 200mm 6 Asr;c:t TSE14 Set623 2 d1 Traffic Siena IHead. LED- tvoe 300mm 1 AsDect TSE15 Amber Lens Unit623 2 d2 Traffic Sianal Head. LED- tvoe 300mm 1 Asoect TSE16 Red Lens Unit623 2 d3 Traffic Sianal Head. LED- tvDe 300mm 1 Asoect TSE17 Green Lens Unit623 2 d4 Traffic Sianal Head. LED-tvoe 300mm 2 Asrn>ct TSE18 Set623 2 d5 Traffic Sianal Head. LED-tvoe 300mm 3 Asoect TSE19 Set623 2 d6 Traffic Sienal Head. LED-tvoe 300mm 4 Asoect TSE20 Set623 2 d7 Traffic Sianal Head. LED-tvoe 300mm 5 Asrn>ct TSE21 Set623 2 d8 Traffic Sianal Head. LED-tvoe 300mm 6 Asoect TSE22 Set623 2 e1 Pedestrian Sianal Head LED-tyoe 300mm 2 Asoect TSE23 Set623 2 e2 Pedestrian Pushbutton Assemblv TSE24 Unit623 2 f1 Mountina Bracket 200mm TSE25 Set623 2 f2 Mountina Bracket 300mm TSE26 Set623 2 a1 Arrow Mask 200mm TSE27 Piece623(2 a2 Arrow Mask 300mm TSE28 Piece

623 (2) h1 Target Board Polycarbonate or Powder-coated Aluminum Substrate for Traffic200mm 3 Aspect TSE29 Piece

Sianal Head

623 (2) h2 Target Board Polycarbonate or Powder-coated Aluminum Substrate for Traffic200mm 4 Aspect TSE30 Piece

Sional Head

623 (2) h3 Target Board Polycarbonate or Powder-coated Aluminum Substrate for Traffic200mm 5 Aspect TSE31 Piece

Sional Head

623 (2) h4Target Board Polycarbonate or Powder-coated Aluminum Substrate for Traffic

200mm 6 Aspect TSE32 PieceSional Head

623 (2) i1Target Board Polycarbonate or Powder-coated Aluminum Substrate for Traffic

300mm 3 Aspect TSE33 PieceSianal Head

623 (2) i2 Target Board Polycarbonate or Powder-coated Aluminum Substrate for Traffic300mm 4 Aspect TSE34 Piece

Sianal Head

623 (2) i3 Target Board Polycarbonate or Powder-coated Aluminum Substrate for Traffic300mm 5 Aspect TSE35 Piece

Sional Head

623 (2) i4 Target Board Polycarbonate or Powder-coated Aluminum Substrate for Traffic300mm 6 Aspect TSE36 Piece

Sional Head

623 (2) j1 Supply & Install Traffic Signal Pole TSE37Type A Mast Arm 4m

Unitoutreach

623 (2) i2 Suoolv & Install Traffic Sional Pole TSE38 Tvoe B Unit623 (2) i3 Suoolv & Install Traffic Sianal Pole TSE39 Tvoe C Unit

Page S2 VOL II

Page 56: Standardized Pay Items of Works for Civil Works Construction for

623 2 i4 Supplv & Install Traffic Siqnal Pole TSE40 Tvoe 0 Unit623 2 k1 Traffic Siqnal Control Cable 4 Core TSE41 Meter623 2 k2 Traffic Sianal Control Cable 8 Core TSE42 Meter623 2 k3 Traffic Siqnal Control Cable 12 Core TSE43 Meter623 2 k4 Traffic Sianal Control Cable 19 Core TSE44 Meter623 2 k5 Traffic Sianal Control Cable 29 Core TSE45 Meter623 2 11 Loop Detector Cable TSE46 Meter623 2 12 Loop Feeder Cable TSE47 Meter623 2 13 Loop Sealant TSE48 Pail623 2 m1 Splicinq Kit TSE49 Piece623 2 n1 Groundina Cable TSE50 Meter623 2 n2 Electricity/Power Suoolv Cable TSE51 Meter623 2 01 Main Circuit Breaker TSE52 Piece623 2 p1 Mountina Strao TSE53 Roll623 2 q1 Mountina Buckle TSE54 Box623 2 r1 Terminal Board (20P) TSE55 Piece623 2 r2 Terminal Luas TSE56 Piece623 2 sl Groundina Rod & Connector TSE57 Set623 3 a1 Install Traffic Sianal Head. LED-type 200mm 2 Asoect TSIl Set623 3 a2 Install Traffic Siqnal Head. LED-type 200mm 3 Aspect TSI2 Set623 3 a3 Install Traffic Siqnal Head. LED-type 200mm 4 Aspect TSI3 Set623 3 a4 Install Traffic Siqnal Head. LED- type 200mm 5 Aspect TSI4 Set623 3 as Install Traffic Sianal Head. LED- tyoe 200mm 6 Asoect TSI5 Set623 3 b1 Install Traffic Sianal Head. LED- type 300mm 2 Asoect TSI6 Set623 3 b2 Install Traffic Sianal Head. LED-type 300mm 3 Asoect TSI7 Set623 3 b3 Install Traffic Siqnal Head. LED-type 300mm 4 Asoect TSI8 Set623 3 b4 Install Traffic Siqnal Head. LED-type 300mm 5 Aspect TSI9 Set623 3 b5 Install Traffic Sianal Head LED-type 300mm 6 Asoect TSIlO Set623 3 c1 Install Pedestrian Sianal Head, LED-type 300mm 2 Asoect TSIl1 Set623 3 c2 Install Pedestrian Pushbutton Assembly TSIl2 Set623 3 c3 Installation of Local Controller inc. Testing & Commissioninq TSIl3 Unit623 3 c4 Loop Detector Installation TSIl4 Slot623 3 c5 Complete Installation of Local Wirinq & Connection to Local Controller TSIl5 Site623 (3) c6 Supply & Install Meter Base Service Entrance & Main Circuit Breaker TSIl6 Site623 (3) c7 Customization of Local Controller TSIl7 Unit

Sin Ie Arm Post with Street Li htSin Ie Arm Post with Street Li htSin Ie Arm Post with Street Li htSin Ie Arm Post with Street Li htSin Ie Arm Post with Street Li htSin Ie Arm Post with Street Li ht

Page 53

130W175W175W

150W-250W250W400W

VOL II

Page 57: Standardized Pay Items of Works for Civil Works Construction for

624(1 b4 Sinale Arm Post. with Street Liaht 12m HPS 400W Each

624 2 al Double Arm Post, with Street Liaht 8m LED BOW Each

624 2 a2 Double Arm Post, with Street Liaht 9m LED 175W Each

624 2 a3 Double Arm Post with Street Liaht 10m LED 175W Each

624 2 bl Double Arm Post with Street Liaht 8m HPS 150W-250W Each624 (2 b2 Double Arm Post with Street Liaht 9m HPS 250W Each

624 2 b3 Double Arm Post with Street Liaht 10m HPS 400W Each

624 2 b4 Double Arm Post with Street Liaht 12m HPS 400W Each

624 3 a Undercarriaqe Luminaire LED 75W Each

624 3 b Undercarriaqe Luminaire HPS 150W Each624 4 Warninq Liqht Complete with Conduits Each624 5 Liqhtinq Control Panel Each624 6 Main Feeder Distribution System Lumo Sum624 7) Photoelectric Cells Each

Page 54 VOL II

Page 58: Standardized Pay Items of Works for Civil Works Construction for

Page 55 VOL II

Page 59: Standardized Pay Items of Works for Civil Works Construction for

Protecttive Coatin for Concrete*Protective coating shall not be measured and paid for separately, but the cost thereof shall be considered as included in the contract unit price of the items where called for.

Page 56

55555 uare MeterLinear MeterCubic Meter

VOL II

Page 60: Standardized Pay Items of Works for Civil Works Construction for

Page 57

Unit Of Measure

Lum Sum

VOl II

Page 61: Standardized Pay Items of Works for Civil Works Construction for

BLUE BOOKVOL. III

Page 62: Standardized Pay Items of Works for Civil Works Construction for

800800800800800 3800 3800 4

abcd

*Refer to Blue Book Volume II, Part A

*Refer to Blue Book Volume II, Part B

150-300 mm dia.301-500 mm dia.501-750 mm dia.751-900 mm dia.

above 900mm dia.

SmallSmallSmallSmallLar e

If<lij~1"1""S1i11· I ]11__ .

801m Removal of Structures and Obstruction Lump Sum801 2 Removal of Actual Structures Obstruction Each801 3 a Removal of Actual Structures Obstruction PCCP Square Meter801 3 b Removal of Actual Structures Obstruction ACP Square Meter801 3) c Removal of Actual Structures Obstruction Sidewalk Sauare Meter801 4) a Removal of Actual Structures Obstruction 610 mm dia. RCPC Linear Meter801 4 b Removal of Actual Structures Obstruction 760 mm dia. RCPC Linear Meter801 4 c Removal of Actual Structures Obstruction 910 mm dia. RCPC Linear Meter801 4 d Removal of Actual Structures Obstruction 1070 mm dia. RCPC Linear Meter801 4 e Removal of Actual Structures Obstruction 1220 mm dia. RCPC Linear Meter801 4 f Removal of Actual Structures Obstruction 1520 mm dia. RCPC Linear Meter801 4 Q Removal of Actual Structures Obstruction Curb Linear Meter801 4 h Removal of Actual Structures/Obstruction Curb and Gutter Linear Meter801 5 a1 Removal of Pipes other than Pipe Culverts 50 mm dia. PVC Linear Meter801 5 a2 Removal of PiDes other than PiDe Culverts 75 mm dia. PVC Linear Meter801 5 a3 Removal of Pipes other than Pipe Culverts 100 mm dia. PVC Linear Meter801 5 a4 Removal of PiDes other than Pipe Culverts 150 mm dia. PVC Linear Meter801 5 as Removal of PiDes other than PiDe Culverts 200 mm dia. PVC Linear Meter801 5 a6 Removal of Pipes other than PiDe Culverts 250 mm dia. PVC Linear Meter

Page 1 VOL III

Page 63: Standardized Pay Items of Works for Civil Works Construction for

-~801 5 a7 Removal of Pipes other than Pipe Culverts 300 mm dia. PVC Linear Meter801 5 bl Removal of Pipes other than Pipe Culverts 150 mm dia. Concrete Linear Meter801 5 b2 Removal of Pioes other than Pioe Culverts 200 mm dia. Concrete Linear Meter801 5 b3 Removal of Pipes other than Pipe Culverts 250 mm dia. Concrete Linear Meter801 5 b4 Removal of Pioes other than Pioe Culverts 300 mm dia. Concrete Linear Meter801 5 b5 Removal of Pipes other than Pipe Culverts 350 mm dia. Concrete Linear Meter

High Density I

801 (5) cl Removal of Pipes other than Pipe Culverts 50 mm dia. Polyethylene Linear MeterHDPE

High Density801 (5) c2 Removal of Pipes other than Pipe Culverts 75 mm dia. Polyethylene Linear Meter

HDPEHigh Density

801 (5) c3 Removal of Pipes other than Pipe Culverts 100 mm dia. Polyethylene Linear MeterHDPE

High Density801 (5) c4 Removal of Pipes other than Pipe Culverts 150 mm dia. Polyethylene Linear Meter

HDPEHigh Density

801 (5) c5 Removal of Pipes other than Pipe Culverts 200 mm dia. Polyethylene Linear Meter, HDPE

High Density801 (5) c6 Removal of Pipes other than Pipe Culverts 250 mmdia. Polyethylene Linear Meter

HDPEHigh Density

801 (5) c7 Removal of Pipes other than Pipe Culverts 300 mm dia. Polyethylene Linear MeterHDPE

801 6 Removal of Structures and Obstruction Concrete Cubic Meter801 7 a Removal of Structures and Obstruction Steel Kiloqram801 7 b Removal of Structures and Obstruction Steel H-Piles Kilogram801 7 c Removal of Structures and Obstruction RSB Kiloqram801 8 Relocation of Utilities Lump Sum801 9 Relocation of Structures Lump Sum

Unsuitable ExcavationSur Ius Common Excavation

a Sur Ius Rock Excavationb Sur Ius Rock Excavation

Sur Ius Unclassified Excavation

Page 2

,SoftHard

Cubic MeterCubic MeterCubic MeterCubic MeterCubic Meter

VOL III

Page 64: Standardized Pay Items of Works for Civil Works Construction for

803 1 a Structure Excavation Common Soil Cubic Meter803 1 b Structure Excavation Soft Rock Cubic Meter803 1 c Structure Excavation Hard Rock Cubic Meter803 2 Trimmin Works S uare Meter803 3 Soil Stabilization S uare Meter

a Embankment Cubic Meter

b Embankment Cubic Metera Selected Borrow for to Cubic Meterb Selected Borrow for to Cubic Meter

Earth Berm Cubic MeterGravel fill Cubic Meter

Page 3

TreesShrubsGrass

Lum SumLum Sum

EachEach

S uare Meter

VOL III

Page 65: Standardized Pay Items of Works for Civil Works Construction for

807 3) b1 Hardscape Lump Sum807 3) b2 Hardscaoe fountains Each807 (3) b3 Hardscape benches Each807 3 b4 Hardscaoe Qazebos Each807 4 Garden Soil Cubic Meter807 5 a Aquatic Plants Each807 5 b Aauatic Animals Each807 6 Paver Blocks Square Meter807 7 Curbs Linear Meter807 8 a Column Guards Pieces807 8 b Wheel Guards Pieces807 9 Fence Square Meter

807 (10) Gate Lump Sum

_ J' 'I '

900 1 Reinforced Concrete Cubic Meter900 1 a1 Structural Concrete A 7 days Cubic Meter900 1 a2 Structural Concrete Footinqs and Slab on Fill) A 7 days Cubic Meter900 1 a3 Structural Concrete Footina Tie Beams) A 7 days Cubic Meter900 1 a4 Structural Concrete Columns) A 7 days Cubic Meter900 1 as Structural Concrete Suspended Slab) A 7 days Cubic Meter900 1 a6 Structural Concrete Beams/Girders) A 7 days Cubic Meter900 1 b1 Structural Concrete A 14 days Cubic Meter900 1 b2 Structural Concrete (FootinQs and Slab on Fill) A 14 days Cubic Meter900 1 b3 Structural Concrete Footinq Tie Beams) A 14 days Cubic Meter900 1 b4 Structural Concrete Columns) A 14 days Cubic Meter900 1 b5 Structural Concrete Susoended Slab) A 14 days Cubic Meter900 1 b6 Structural Concrete (Beams/Girders) A 14 days Cubic Meter900 1 c1 Structural Concrete A 28 days Cubic Meter900 1 c2 Structural Concrete Footinas and Slab on Fill) A 28 days Cubic Meter900 1 c3 Structural Concrete FootinQ Tie Beams) A 28 days Cubic Meter900 1 c4 Structural Concrete Columns) A 28 days Cubic Meter900 1 c5 Structural Concrete Suspended Slab) A 28 days Cubic Meter900 1 c6 Structural Concrete (Beams/Girders) A 28 days Cubic Meter900 2 a Structural Concrete B 7 days Cubic Meter900 2 b Structural Concrete B 14 days Cubic Meter900 2 c Structural Concrete B 28 days Cubic Meter900 3 a Structural Concrete C 7 days Cubic Meter900 3) b Structural Concrete C 14 days Cubic Meter900 (3) c Structural Concrete C 28 days Cubic Meter

Page 4 VOL III

Page 66: Standardized Pay Items of Works for Civil Works Construction for

struCturai Concrete-~.~-.. .•.. -,

900 a p .Cubic Meter900 b Structural Concrete p Cubic Meter900 c Structural Concrete p Cubic Meter900 Structural Concrete AA Cubic Meter900 Seal Concrete Cubic Meter

Page 5

50 mm dia.75 mm dia.100 mm dia.150 mm dia.50 mm dia.75 mm dia.

Series 600Series 600Series 600Series 600

Series 1000Series 1000

Unit Of Measure

LiterLiter

Kilo ram

MeterMeterMeterMeterMeterMeter

VOLUME III

Page 67: Standardized Pay Items of Works for Civil Works Construction for

1001 (1 a7 Pipe 100 mm dia. PVC Series 1000 Meter1001 (1 a8 PiDe 150 mm dia. PVC Series 1000 Meter1001 (1 a9 Pipe 200 mm dia. PVC Series 1000 Meter100 1 (1 ala PiDe 250 mm dia. PVC Series 1000 Meter1001 1 all PiDe 300 mm dia. PVC Series 1000 Meter '1001 1 b1 Pipe 150 mm dia. Concrete Meter1001 1 b2 PiDe 200 mm dia. Concrete Meter1001 1 b3 PiDe 250 mm dia. Concrete Meter10017i) b4 PiDe 300 mm dia. Concrete Meter1001 1 b5 PiDe 350 mm dia. Concrete Meter

High Density1001 (1) c1 Pipe 50 mm dia. Polyethylene Meter

HDPEHigh Density

1001 (1) c2 Pipe 75 mm dia. Polyethylene MeterHDPE

High Density1001 (1) c3 Pipe 100 mm dia. Polyethylene Meter

HDPEHigh Density

1001 (1) c4 Pipe 150 mm dia. Polyethylene MeterHDPE

High Density1001 (1) c5 Pipe 200 mm dia. Polyethylene Meter

HDPEHigh Density

1001 (1) c6 Pipe 250 mm dia. Polyethylene MeterHDPE

High Density,

1001 (1) c7 Pipe 300 mm dia. Polyethylene MeterHDPE

1001 (2) a1 Fittings 50 mm dia. PVC(Elbow, 1/8 Bend (45

Eachdea. ))

1001 (2) a2 Fittings 75 mm dia. PVC (Elbow, 1/8 Bend (45Eachdea. ))

1001 (2) a3 Fittings 100 mm dia. PVC(Elbow, 1/8 Bend (45

Eachdea. ))

1001 (2) a4 Fittings 150 mm dia. PVC (Elbow, 1/8 Bend (45Eachdea.))

1001 (2) as Fittings 200 mm dia. PVC(Elbow, 1/8 Bend (45

Eachdea. ))

1001 (2) a6 Fittings 250 mm dia. PVC(ELbow, 1/8 Bend (45

Eachdea.))

Page 6 VOLUME III

Page 68: Standardized Pay Items of Works for Civil Works Construction for

1001 (2) a7 Fittings 300 mm dia. PVC(Elbow, 1/8 Bend (45

Eachdea.))

1001 (2) bl Fittings 50 mm dia. PVC(Elbow, 1/4 Bend (90

Eachdea.))

1001 (2) b2 Fittings 75 mm dia. PVC(Elbow, 1/4 Bend (90

Eachdea.))

1001 (2) b3 Fittings 100 mm dia. PVC(Elbow, 1/4 Bend (90

Eachdea,))

1001 (2) b4 Fittings 150 mm dia. PVC(Elbow, 1/4 Bend (90

Eachdea,))

1001 (2) b5 Fittings 200 mm dia. PVC(Elbow, 1/4 Bend (90

Eachdea. ))

1001 (2) b6 Fittings 250 mm dia. PVC(Elbow, 1/4 Bend (90

Eachdea.))

1001 (2) b7 Fittings 300 mm dia. PVC(Elbow, 1/4 Bend (90

Eachdea.))1001 2) cl Fittinas 50 mm dia. PVC Clean Out with Plua Each1001 2 c2 Fittinqs 75 mm dia. PVC Clean Out with Plua Each1001 2 c3 Fittinas 100 mm dia. PVC Clean Out with Pluq Each1001 2 c4 FittinQs 150 mm dia. PVC Clean Out with Plua Each1001 2 c5 Fittinqs 200 mm dia. PVC Clean Out with Pluq Each1001 2 c6 Fittinas 250 mm dia. PVC Clean Out with Pluq Each1001 2 c7 Fittinqs 300 mm dia. PVC Clean Out with PluQ Each1001 2 dl FittinQs 50 mm dia. PVC Couolina Each1001 2 d2 Fittinqs 75 mm dia. PVC CouplinQ Each1001 2 d3 Fittinqs 100 mm dia. PVC Couplinq Each100 1 2 d4 Fittinas 150 mm dia. PVC Couolina Each1001 2 d5 Fittinas 200 mm dia. PVC Couolina Each1001 (2 d6 Fittinas 250 mm dia. PVC Couolina Each1001 2 d7 Fittinas 300 mm dia. PVC Couplinq Each1001 2 el FittinQs 50 mm dia. PVC P-trap Each1001 2 e2 Fittinqs 75 mm dia. PVC P-trap Each1001 2 e3 FittinQs 100 mm dia. PVC P-trao Each1001 2 fl Fittinas 50 mm dia. PVC Sanitary Tee Each1001 2 f2 FittinQs 75 mm dia. PVC Sanitary Tee Each1001 2 f3 Fittinqs 100 mm dia. PVC Sanitary Tee Each1001 2 f4 Fittinas 150 mm dia. PVC Sanitary Tee Each1001 (2) f5 Fittinqs 200 mm dia. PVC Sanitary Tee Each1001 (2) f6 Fittinas 250 mm dia. PVC Sanitary Tee Each100 1 2 f7 Fittinqs 300 mm dia. PVC Sanitary Tee Each1001 2 ql Fittinqs 50 mm dia. PVC Sanitary Wye Each1001 2 q2 Fittinqs 75 mm dia. PVC Sanitary Wye Each1001 2 a3 Fittinas 100 mm dia. PVC Sanitary Wve Each

Page 7 VOl III

Page 69: Standardized Pay Items of Works for Civil Works Construction for

1001 2 04 Fittinos 150 mm dia. PVC SanitarY Wve Each1001 2 05 Fittinos 200 mm dia. PVC SanitarY Wve Each1001 2 06 Fittinos 2s0mm dia. PVC SanitarY Wve Each1001 2 07 Fittinos 300 mm dia. PVC Sanitary Wye Each

1001 (2) hl FittingssOmm dia. x 32mm

PVC Sanitary Tap Tee Eachdia.

1001 (2) h2 FittingssOmm dia. x 40mm

PVC Sanitary Tap Tee Eachdia.

1001 (2) il Fittings7smm dia. x sOmm

PVC Reducer-Bushing Eachdia.

1001 (2) i2 Fittings100mm dia. x sOmm

PVC Reducer-Bushing Eachdia.

1001 (2) i3 Fittings100mm dia. x 7smm

PVC Reducer-Bushing Eachdia.

1001 (2) i4 Fittingsls0mm dia. x 100mm

PVC Reducer-Bushing Eachdia.

1001 (2) is Fittings200mm dia. x 100mm

PVC Reducer-Bushing Eachdia.

1001 (2) i6 Fittings200mm dia. x ls0mm

PVC Reducer-Bushing Eachdia.

1001 (2) jl Fittings7smm dia. x sOmm

PVC Reducer-Coupling Eachdia.

1001 (2) j2 Fittings 100mm dia. x sOmmPVC Reducer-Coupling Each

dia.

1001 (2) j3 Fittings100mm dia. x 7smm

PVC Reducer-Coupling Eachdia.

1001 (2) j4 Fittingsls0mm dia. x 100mm

PVC Reducer-Coupling Eachdia.

1001 (2) js Fittings200mm dia. x 100mm

PVC Reducer-Coupling Eachdia.

1001 (2) j6 Fittings 200mm dia. x ls0mmPVC Reducer-Coupling Each

dia.

1001 (2) kl Fittings 7smm dia. x sOmmPVC Reducer - Sanitary Tee Each

dia.

1001 (2) k2 Fittings 100mm dia. x sOmmPVC Reducer - Sanitary Tee Each

dia.

1001 (2) k3 Fittings 100mm dia. x 7smmPVC Reducer - Sanitary Tee Each

dia.

1001 (2) k4 Fittingsls0mm dia. x 100mm

PVC Reducer - Sanitary Tee Eachdia.

1001 (2) ks Fittings200mm dia. x 100mm

PVC Reducer - Sanitary Tee Eachdia.

Page 8 VOL III

Page 70: Standardized Pay Items of Works for Civil Works Construction for

1001 (2) k6 Fittings200mm dia. x 150mm

PVC Reducer - Sanitary Tee Eachdia.

1001 (2) 11 Fittings75mm dia. x 50mm

PVC Reducer - Sanitary Wye Eachdia.

1001 (2) 12 Fittings100mm dia. x 50mm

PVC Reducer - Sanitary Wye Eachdia.

1001 (2) 13 Fittings100mm dia. x 75mm

PVC Reducer - Sanitary Wye Eachdia.

1001 (2) 14 Fittings150mm dia. x 100mm

PVC Reducer - Sanitary Wye Eachdia.

1001 (2) 15 Fittings200mm dia. x 100mm

PVC Reducer - Sanitary Wye Eachdia.

1001 (2) 16 Fittings200mm dia. x 150mm

PVC Reducer - Sanitary Wye Eachdia.

1001 (2) m1 Fittings 50 mm dia. HOPE(Elbow, 1/8 Bend (45 Each

dea -"

1001 (2) m2 Fittings 75 mm dia. HOPE(Elbow, 1/8 Bend (45

Eachdea,))

1001 (2) m3 Fittings 100 mm dia. HOPE(Elbow, 1/8 Bend (45

Eachdea-"

1001 (2) m4 Fittings,

150 mm dia. HOPE(Elbow, 1/8 Bend (45

Eachdea.))

1001 (2) m5 Fittings 200 mm dia. HOPE(Elbow, 1/8 Bend (45 Each

dea. "

1001 (2) m6 Fittings 50 mm dia. HOPE(Elbow, 1/8 Bend (90 Each

dea-"

1001 (2) m7 Fittings 75 mm dia. HOPE(Elbow, 1/8 Bend (90 Eachdea.))

1001 (2) m8 Fittings 100 mm dia. HOPE(Elbow, 1/8 Bend (90 Eachdea. ))

1001 (2) m9 Fittings 150 mm dia. HOPE(Elbow, 1/8 Bend (90 Each

dea. "

1001 (2) nl Fittings 50 mm dia. HOPEClean Out Plug with

EachAdantor

1001 (2) n2 Fittings 75 mm dia. HOPEClean Out Plug with Each

Adantor

1001 (2) n3 Fittings 100 mm dia. HOPEClean Out Plug with Each

Adantor1001 2 01 Fittinas 50 mm dia. HOPE Couolina Each1001 2 02 Fittinas 75 mm dia. HOPE Counlina Each1001 2 03 Fittinas 100 mm dia. HOPE Couolina Each1001 2 04 Fittinas 150 mm dia. HOPE Couolina Each1001 2 05 Fittinas 200 mm dia. HOPE CouDlina Each

Page 9 VOL III

Page 71: Standardized Pay Items of Works for Civil Works Construction for

1001 2) 06 Fittinos--...-..- .-_ .. _._---~,_.,---"...- - ---_ .._-,.~---

250 mm dia. Couolino EachHOPE1001 2) 07 Fittinos 300 mm dia. HOPE Couolino Each1001 2 0 Fittinos 50 mm dia. HOPE P-trao Each1001 2 01 Fittinos 50 mm dia. HOPE Straioht - SanitarY Tee Each1001 2 02 Fittinos 75 mm dia. HOPE Straioht - SanitarY Tee Each1001 2 03 Fittinos 100 mm dia. HOPE Straioht - Sanitarv Tee Each1001 2 04 Fittinos 150 mm dia. HOPE Straioht - SanitarY Tee Each1001 2 05 Fittinos 200 mm dia. HOPE Straioht - Sanitarv Tee Each1001 2 r1 Fittinos 75 mm x 50mm HOPE Reducer - SanitarY Tee Each1001 2 r2 Fittinos 100mm x 50mm HOPE Reducer - SanitarY Tee Each1001 2 r3 Fittinos 100mm x 75mm HOPE Reducer - SanitarY Tee Each1001 2 r4 Fittinos 150mm x 75 mm HOPE Reducer - SanitarY Tee Each1001 2 r5 Fittinos 150mm x 100mm HOPE Reducer - SanitarY Tee Each1001 2 r6 Fittinos 200mm x 100mm HOPE Reducer - SanitarY Tee Each1001 (2) sl Fittings 50 mm dia. HOPE Straight - Sanitary Wye 45 Eachdeo.1001 (2) s2 Fittings 75 mm dia. HOPE Straight - Sanitary Wye 45 Eachdeo.1001 (2) s3 Fittings 100 mm dia. HOPE Straight - Sanitary Wye 45 Eachdeo.1001 (2) s4 Fittings 150 mm dia. HOPE Straight - Sanitary Wye 45 Eachdeo.1001 (2) s5 Fittings 200 mm dia. HOPE Straight - Sanitary Wye 45 Eachdeo.1001 (2) s6 Fittings 250 mm dia. HOPE Straight - Sanitary Wye 45 Eachdeo.1001 (2) s7 Fittings 300 mm dia. HOPE Straight - Sanitary Wye 45 Eachdeo.1001 (2) t1 Fittings 75mm dia. x 50mm

HOPE Reducer - Sanitary Wye 45 Eachdia. deo.1001 (2) t2 Fittings 100mm dia. x 50mm HOPE Reducer - Sanitary Wye 45 Eachdia. deo.1001 (2) t3 Fittings 100mm dia. x 75mm HOPE Reducer - Sanitary Wye 45 Eachdia. deo.1001 (2) t4 Fittings 150mm dia. x 100mm HOPE Reducer - Sanitary Wye 45 Eachdia. den.1001 (2) t5 Fittings 150mm dia. x 100mm HOPE Reducer - Sanitary Wye 45 Each

dia. den.1001 (2) t6 Fittings 200mm dia. x 100mm

HOPE Reducer - Sanitary Wye 45 Eachdia. den.

1001 (2) t7 Fittings 200mm dia. x 150mm HOPE Reducer - Sanitary Wye 45 Eachdia. deo.

Page 10 VOL III

Page 72: Standardized Pay Items of Works for Civil Works Construction for

1001 (2) t8 Fittings250mm dia. x 100mm

HOPEReducer - Sanitary Wye 45

dia. den.Each

1001 (2) t9 Fittings250mm dia. x 150mm

HOPEReducer - Sanitary Wye 45

dia. dea. Each

1001 (2) tlO Fittings250mm dia. x 200mm

HOPEReducer - Sanitary Wye 45

dia. den.Each

1001 (2) tll Fittings300mm dia. x 100mm

HOPEReducer - Sanitary Wye 45

dia. den. Each

1001 (2) tl2 Fittings300mm dia. x 150mm

HOPEReducer - Sanitary Wye 45

dia. den. Each

1001 (2) tl3 Fittings300mm dia. x 200mm

HOPEReducer - Sanitary Wye 45

dia. den.Each

1001 (2) tl4 Fittings300mm dia. x 250mm

HOPEReducer - Sanitary Wye 45

dia. dea.Each

1001 (2) ul Fittings 50 mm dia. HOPEStraight - Sanitary Wye 90

Eachden.

1001 (2) u2 Fittings 75 mm dia. HOPEStraight - Sanitary Wye 90

Each

1001 (2) u3 Fittinasden.

100 mm dia. HOPE StraiQht - Sanitarv Wye 90 Each

1001 (2) u4 Fittings 150 mm dia. HOPEStraight - Sanitary Wye 90

Eachden.

1001 (2) uS Fittings 200 mm dia. HOPEStraight - Sanitary Wye 90

Eachden.

1001 (2) u6 Fittings 250 mm dia. HOPEStraight - Sanitary Wye 90

Eachden.

1001 (2) u7 Fittings 300 mm dia. HOPEStraight - Sanitary Wye 90

Eachden.

1001 (2) vl Fittings 7Smm dia. x SOmm dia. HOPEReducer - Sanitary Wye 90

Eachden.

1001 (2) v2 Fittings 100mm dia. x SOmm dia. HOPEReducer - Sanitary Wye 90

Eachdea.

1001 (2) v3 Fittings 100mm dia. x 7Smm dia. HOPEReducer - Sanitary Wye 90

Eachdea.

1001 (2) v4 Fittings lS0mm dia. x 7Smm dia. HOPEReducer - Sanitary Wye 90

Eachden.

1001 (2) v5 FittingslS0mm dia. x 100mm

HOPEReducer - Sanitary Wye 90

dia. dea.Each

1001 (2) v6 Fittings200mm dia. x 100mm

HOPEReducer - Sanitary Wye 90

dia. dea.Each

1001 (2) v7 Fittings200mm dia. x lS0mm

HOPEReducer - Sanitary Wye 90

dia. dea.Each

1001 (2) v8 Fittings2S0mm dia. x 100mm

HOPEReducer - Sanitary Wye 90

dia. den.Each

Page 11 VOL III

Page 73: Standardized Pay Items of Works for Civil Works Construction for

1001 (2) v9 Fittings2S0mm dia. x lS0mm HDPE

Reducer - Sanitary wye 90 Eachr1ji'l rip;'

1001 (2) v10 Fittings2S0mm dia. x 200mm HDPE

Reducer - Sanitary Wye 90Each

dia. deq.

1001 (2) vll Fittings300mm dia. x 100mm HDPE

Reducer - Sanitary Wye 90Each'

dia. dea.

1001 (2) v12 Fittings300mm dia. x lS0mm HDPE

Reducer - Sanitary Wye 90Each

dia. dea.

1001 (2) vB Fittings300mm dia. x 200mm HDPE

Reducer - Sanitary Wye 90Each

dia. dea.

1001 (2) v14 Fittings300mm dia. x 2S0mm HDPE

Reducer - Sanitary Wye 90 Eachdia. dea.

1001 (2) w1 Fittings 7Smm dia. x SOmm dia. HDPE Reducer - Bushing Each

1001 (2) w2 Fittings 100mm dia. x SOmm dia. HDPE Reducer - Bushing Each

1002 (2) w3 Fittings 100mm dia. x 7Smm dia. HDPE Reducer - Bushing Each

1001 (2) w4 FittingslS0mm dia. x 100mm HDPE Reducer - Bushing Each

dia.

1001 (2) w5 Fittings200mm dia. x 100mm HDPE Reducer - Bushing Each

dia.

1001 (2) w6 Fittings200mm dia. x lS0mm HDPE Reducer - Bushing Each

dia.

1001 (2) w7 Fittings2S0mm dia. x 200mm HDPE Reducer - Bushing Each

dia.

1001 (2) w8 Fittings300mm dia. x 200mm HDPE Reducer - Bushing Each

dia.

1001 (2) w9 Fittings300mm dia. x 2S0mm HDPE Reducer - Bushing Each

r1i::>

1001 (3) Concrete Gutter Meter1001 (4 Concrete Canal Meter1001 (5 Wrouqht Iron Gratinq Square Meter1001 (6 a Catch Basin Concrete Each1001 6 b Catch Basin CHB Each1001 7 a Junction Box Concrete Each1001 7 b Junction Box CHB Each1001 (8 Sewer Line Works Lump Sum1001 (9) Storm Drainaqe and DownsDout Lump Sum

Page 12 VOL III

Page 74: Standardized Pay Items of Works for Civil Works Construction for

1002 (1) a3 Cast Iron Soil Pioe 100 mm dia. Piece1002 (1) a4 Cast Iron Soil Pioe 150 mm dia. Piece1002 (1) bl Fittings - Cast Iron 50 mm dia. (Elbow, 1/8 Bend (45

Piecedea.n1002 (1) b2 Fittings - Cast Iron 75 mm dia. (Elbow, 1/8 Bend (45

Piecedea.))1002 (1) b3 Fittings - Cast Iron 100 mm dia. (Elbow, 1/8 Bend (45

Piecedea.))1002 (1) b4 Fittings - Cast Iron 150 mm dia. (Elbow, 1/8 Bend (45

Piecedea.))1002 (1) cl Fittings - Cast Iron 50 mm dia. (Elbow, 1/4 Bend (90

Piecedea,))1002 (1) c2 Fittings - Cast Iron 75 mm dia. (Elbow, 1/4 Bend (90

Piecedea.n1002 (1) c3 Fittings - Cast Iron 100 mm dia. (Elbow, 1/4 Bend (90

Piecedea.n1002 (1) c4 Fittings - Cast Iron 150 mm dia. (Elbow, 1/4 Bend (90

Piecedea.))1002 (1) dl Fittings - Cast Iron 50 mm dia. Long Sweep (Elbow, 1/4 Bend (90

Piecedea. n1002 (1) d2 Fittings - Cast Iron 75 mm dia. Long Sweep (Elbow, 1/4 Bend (90

Piecedea. n

1002 (1) d3 Fittings - Cast Iron 100 mm dia. Long Sweep (Elbow, 1/4 Bend (90Piecedea.))

1002 (1) d4 Fittings - Cast Iron 150 mm dia. Long Sweep (Elbow, 1/4 Bend (90Piecedea. ))

1002 1) el FittinQs - Cast Iron 50 mm dia. Pluas Piece1002 1 e2 FittinQs - Cast Iron 75 mm dia. PluQS Piece1002 1 e3 Fittinas - Cast Iron 100 mm dia. Pluas Piece1002 1 e4 FittinQs - Cast Iron 150 mm dia. Pluas Piece1002 1 f1 Fittings - Cast Iron 50 mm dia. P-Trao Piece1002 1 f2 Fittings - Cast Iron 75 mm dia. P-Trao Piece1002 1 f3 FittinQs - Cast Iron 100 mm dia. P-Trao Piece1002 1 f4 Fittings - Cast Iron 150 mm dia. P-Trao Piece1002 1 al Fittings - Cast Iron 50 mm dia. Sanitary Tee Piece1002 1 g2 Fittings - Cast Iron 75 mm dia. Sanitary Tee Piece1002 1 g3 FittinQs - Cast Iron 100 mm dia. Sanitary Tee Piece1002 1 g4 Fittings - Cast Iron 150 mm dia. Sanitary Tee Piece1002 (1) h Fittings - Cast Iron 50mm dia. x 40mm

Sanitary Tap Tee Piecedia.1002 (1) il Fittings - Cast Iron 50 mm dia. Straight - Sanitary Wye

Piece(45 dea,)

Page 13 VOL III

Page 75: Standardized Pay Items of Works for Civil Works Construction for

1002 (1) i2 Fittings - Cast Iron 75 mm dia.Straight - Sanitary Wye Piece

(45 dea.) :

1002 (1) i3 Fittings - Cast Iron 100 mm dia.Straight - Sanitary Wye Piece

(45 dea.)

1002 (1) i4 Fittings - Cast Iron 150 mm dia.Straight - Sanitary Wye Piece

(45 dea.)

1002 (1) j1 Fittings - Cast Iron75mm dia. x 50mm Reducer - Sanitary Wye

dia. (45 dea.)Piece

1002 (1) j2 Fittings - Cast Iron100mm dia. x 50mm Reducer - Sanitary Wye

dia. (45 dea.)Piece

1002 (1) j3 Fittings - Cast Iron100mm dia. x 75mm Reducer - Sanitary Wye

dia. (45 dee.)Piece

1002 (1) j4 Fittings - Cast Iron150mm dia. x 100mm Reducer - Sanitary Wye

dia. (45 dea.)Piece

1002 (1) k1 Fittings - Cast Iron 50 mm dia.Straight - Sanitary Wye Piece

(90 dee.)

1002 (1) k2 Fittings - Cast Iron 75 mm dia.Straight - Sanitary Wye Piece

(90 dee.)

1002 (1) k3 Fittings - Cast Iron 100 mm dia.Straight - Sanitary Wye Piece

(90 dea.)

1002 (1) k4 Fittings - Cast Iron 150 mm dia.Straight - Sanitary Wye Piece

(90 dee,)

1002 (1) 11 Fittings - Cast Iron75mm dia. x 50mm Reducer - Sanitary Wye

dia. (90 dea,)Piece

1002 (1) 12 Fittings - Cast Iron100mm dia. x 50mm Reducer - Sanitary Wye

dia. (90 dee.)Piece

1002 (1) 13 Fittings - Cast Iron100mm dia. x 75mm Reducer - Sanitary Wye

dia. (90 dea,)Piece

1002 (1) 14 Fittings - Cast Iron150mm dia. x 100mm Reducer - Sanitary Wye

dia. (90 dee.)Piece

1002 (2) a1 Galvanized Iron Pines1002 (2) a2 Galvanized Iron pines

13 mm dia. Piece

1002 2 a3 Galvanized Iron Pioes25 mm dia. Piece

1002 2 a4 Galvanized Iron Pioes32 mm dia. Piece

1002 2 as Galvanized Iron pines40 mm dia. Piece

1002 2 a6 Galvanized Iron Pioes50 mm dia. Piece

1002 2 a7 Galvanized Iron Pines65 mm dia. Piece

1002 2 a8 Galvanized Iron Pioes75 mm dia. Piece100 mm dia.

1002 (2 a9 Galvanized Iron pinesPiece

150 mm dia. Piece

1002 (2) b1 Fittings - Galvanized Iron 13 mm dia.(Elbow, 1/4 Bend (90 Piece

dee.))

1002 (2) b2 Fittings - Galvanized Iron 20 mm dia.(Elbow, 1/4 Bend (90 Piece

dee.))

Page 14 VOL III

Page 76: Standardized Pay Items of Works for Civil Works Construction for

1002 (2) b3 Fittings - Galvanized Iron 25 mm dia.(Elbow, 1/4 Bend (90

Piecedea. ))

1002 (2) b4 Fittings - Galvanized Iron 32 mm dia.(Elbow, 1/4 Bend (90

Piecedea.))

1002 (2) b5 Fittings - Galvanized Iron 40 mm dia.(Elbow, 1/4 Bend (90

Piecedea. ))

1002 (2) b6 Fittings - Galvanized Iron 50 mm dia.(Elbow, 1/4 Bend (90

Piecedea.))

1002 (2) b7 Fittings - Galvanized Iron 65 mm dia.(Elbow, 1/4 Bend (90

Piecedea.))

1002 (2) b8 Fittings - Galvanized Iron 75 mm dia.(Elbow, 1/4 Bend (90

Piecedea. ))

1002 (2) b9 Fittings - Galvanized Iron 100 mm dia.(Elbow, 1/4 Bend (90

Piecedea. ))

1002 (2) bl0 Fittings - Galvanized Iron 150 mm dia.(Elbow, 1/4 Bend (90

Piecedea.))1002 2 cl Fittinas - Galvanized Iron 13 mm dia. Tee Eaual Piece1002 2 c2 Fittinas - Galvanized Iron 20 mm dia. Tee Eaual Piece1002 2 c3 Fittinas - Galvanized Iron 25 mm dia. Tee Eaual Piece1002 2 c4 Fittinas - Galvanized Iron 32 mm dia. Tee Eaual Piece1002 2 c5 Fittinas - Galvanized Iron 40 mm dia. Tee Eaual Piece1002 2 c6 Fittinas - Galvanized Iron 50 mm dia. Tee Eaual Piece1002 2 c7 Fittinas - Galvanized Iron 65 mm dia. Tee Eaual Piece1002 2 c8 Fittinas - Galvanized Iron 75 mm dia. Tee Eaual Piece1002 2 c9 Fittinas - Galvanized Iron 100 mm dia. Tee Eaual Piece1002 2 clO Fittinas - Galvanized Iron 150 mm dia. Tee Eaual Piece

1002 (2) dl Fittings - Galvanized Iron 20mm dia. x 13mmReducer - Tee (Unequal) Piecedia.

1002 (2) d2 Fittings - Galvanized Iron 25mm dia. x 13mmReducer - Tee (Unequal) Piecedia.

1002 (2) d3 Fittings - Galvanized Iron 25mm dia. x 20mmReducer - Tee (Unequal) Piecedia.

1002 (2) d4 Fittings - Galvanized Iron 32mm dia. x 13mmReducer - Tee (Unequal) Piecedia.

1002 (2) d5 Fittings - Galvanized Iron 32mm dia. x 20mmReducer - Tee (Unequal) Piecedia.

1002 (2) d6 Fittings - Galvanized Iron 32mm dia. x 25mmReducer - Tee (Unequal) Piecedia.

1002 (2) d7 Fittings - Galvanized Iron 40mm dia. x 13mmReducer - Tee (Unequal) Piecedia.

1002 (2) d8 Fittings - Galvanized Iron 40mm dia. x 20mmReducer - Tee (Unequal) Piecedia.

Page 15 VOL III

Page 77: Standardized Pay Items of Works for Civil Works Construction for

1002 (2) d9 Fittings - Galvanized Iron40mm dia. x 25mm Reducer - Tee (Unequal) Piece

dia.

1002 (2) d10 Fittings - Galvanized Iron40mm dia. x 32mm Reducer - Tee (Unequal) Piece

dia.

1002 (2) dl1 Fittings - Galvanized Iron50mm dia. x 13mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d12 Fittings - Galvanized Iron50mm dia. x 20mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d13 Fittings - Galvanized Iron50mm dia. x 25mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d14 Fittings - Galvanized Iron50mm dia. x 32mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d15 Fittings - Galvanized Iron50mm dia. x 40mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d16 Fittings - Galvanized Iron65mm dia. x 32mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d17 Fittings - Galvanized Iron65mm dia. x 40mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d18 Fittings - Galvanized Iron65mm dia. x 50mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d19 Fittings - Galvanized Iron75mm dia. x 32mm Reducer - Tee (Unequal) Piece

dia.

1002 (2) d20 Fittings - Galvanized Iron75mm dia. x 40mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d21 Fittings - Galvanized Iron75mm dia. x 50mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d22 Fittings - Galvanized Iron75mm dia. x 65mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d23 Fittings - Galvanized Iron100mm dia. x 40mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d24 Fittings - Galvanized Iron100mm dia. x 50mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d25 Fittings - Galvanized Iron100mm dia. x 65mm

Reducer - Tee (Unequal) Piecedia.

1002 (2) d26 Fittings - Galvanized Iron100mm dia. x 75mm

Reducer - Tee (Unequal) Piecedia.

1002 2 e1 Fittinas - Galvanized Iron 13 mm dia. Socket Couolina Piece1002 2 e2 FittinQs - Galvanized Iron 20 mm dia. Socket Couplinq Piece1002 2 e3 Fittinas - Galvanized Iron 25 mm dia. Socket CouolinQ Piece1002 2 e4 FittinQs - Galvanized Iron 32 mm dia. Socket Couplinq Piece1002 2 e5 Fittinas - Galvanized Iron 40 mm dia. Socket CouolinQ Piece1002 2 e6 FittinQs - Galvanized Iron 50 mm dia. Socket Couolina Piece1002 2 e7 Fittinas - Galvanized Iron 65 mm dia. Socket CouplinQ Piece

Page 16 VOL III

Page 78: Standardized Pay Items of Works for Civil Works Construction for

1002 (2) e8 Fittinas - Galvanized Iron 75 mm dia. Socket/Couolina Piece1002 (2) e9 Fittinas - Galvanized Iron 100 mm dia. SocketlCouDlina Piece1002(if e10 Fittinas - Galvanized Iron 150 mm dia. SocketlCouDlina Piece

1002 (2) f1 Fittings - Galvanized Iron 20mm dia. x 13mmReducer - Coupling Piece

dia.

1002 (2) f2 Fittings - Galvanized Iron 25mm dia. x 13mmReducer - Coupling Piece

dia.

1002 (2) f3 Fittings - Galvanized Iron 25mm dia. x 20mmReducer - Coupling Piece

dia.

1002 (2) f4 Fittings - Galvanized Iron32mm dia. x 13mm

Reducer - Coupling Piecedia.

1002 (2) f5 Fittings - Galvanized Iron32mm dia. x 20mm

Reducer - Coupling Piecedia.

1002 (2) f6 Fittings - Galvanized Iron32mm dia. x 25mm

Reducer - Coupling Piecedia.

1002 (2) f7 Fittings - Galvanized Iron40mm dia. x 13mm

Reducer - Coupling Piecedia.

1002 (2) f8 Fittings - Galvanized Iron40mm dia. x 20mm

Reducer - Coupling Piecedia.

1002 (2) f9 Fittings - Galvanized Iron40mm dia. x 25mm

Reducer - Coupling Piecedia.

1002 (2) flO Fittings - Galvanized Iron 40mm dia. x 32mmReducer - Coupling Piece

dia.

1002 (2) f11 Fittings - Galvanized Iron 50mm dia. x 13mmReducer - Coupling Piece

dia.

1002 (2) fl2 Fittings - Galvanized Iron 50mm dia. x 20mmReducer - Coupling Piece

dia.

1002 (2) f13 Fittings - Galvanized Iron 50mm dia. x 25mmReducer - Coupling Piece

dia.

1002 (2) fl4 Fittings - Galvanized Iron 50mm dia. x 32mmReducer - Coupling Piece

dia.

1002 (2) fl5 Fittings - Galvanized Iron 50mm dia. x 40mmReducer - Coupling Piece

dia.

1002 (2) f16 Fittings - Galvanized Iron 65mm dia. x 32mmReducer - Coupling Piecedia.

1002 (2) f17 Fittings - Galvanized Iron65mm dia. x 40mm

Reducer - Coupling Piecedia.

1002 (2) f18 Fittings - Galvanized Iron65mm dia. x 50mm

Reducer - Coupling Piecedia.

1002 (2) f19 Fittings - Galvanized Iron75mm dia. x 32mm

Reducer - Coupling Piecedia.

1002 (2) f20 Fittings - Galvanized Iron75mm dia. x 40mm

Reducer - Coupling Piecedia.

Page 17 VOL III

Page 79: Standardized Pay Items of Works for Civil Works Construction for

1002 (2) f21 Fittings - Galvanized Iron75mm dia. x 50mm Reducer - Coupling Piece

dia.

1002 (2) f22 Fittings - Galvanized Iron75mm dia. x 65mm Reducer - Coupling Piece

dia.

1002 (2) f23 Fittings - Galvanized Iron100mm dia. x 40mm Reducer - Coupling Piece

dia.

1002 (2) f24 Fittings - Galvanized Iron100mm dia. x 50mm Reducer - Coupling Piece

dia.

1002 (2) f25 Fittings - Galvanized Iron100mm dia. x 65mm Reducer - Coupling Piece

dia.

1002 (2) f26 Fittings - Galvanized Iron 100mm dia. x 75mm Reducer - Coupling Piecedia.

1002 3 al Polvoroohvlene Random Cooolvmer PPR-C Pioes 13 mm dia. PN 10 Piece1002 3 a2 Polvoroohvlene Random Cooolvmer PPR-C Pioes 13 mm dia. PN 16 Piece1002 3 a3 Polvoroohvlene Random Cooolvmer PPR-C Pioes 13 mm dia. PN 20 Piece1002 3 a4 Polvoroohvlene Random Cooolvmer PPR-C Pioes 20 mm dia. PN 10 Piece1002 3 as Polvoroohvlene Random Cooolvmer PPR-C Pioes 20 mm dia. PN 16 Piece1002 3 a6 Polvoroohvlene Random Cooolvmer PPR-C Pioes 20 mm dia. PN 20 Piece1002 3 a7 Polvoroohvlene Random Cooolvmer PPR-C Pioes 25 mm dia. PN 10 Piece1002 3 a8 Polvoroohvlene Random Cooolvmer PPR-C Pioes 25 mm dia. PN 16 Piece1002 3 a9 Polvoroohvlene Random Cooolvmer PPR-C Pioes 25 mm dia. PN 20 Piece1002 3 al0 Polvoroohvlene Random Cooolvmer PPR-C Pioes 32 mm dia. PN 10 Piece1002 3 all Polvoroohvlene Random Cooolvmer PPR-C Pioes 32 mm dia. PN 16 Piece1002 (3) a12 Polvoroohvlene Random Cooolvmer PPR-C Pioes 32 mm dia. PN 20 Piece1002 (3) a13 Polvoroohvlene Random CoDolvmer PPR-C PiDes 40 mm dia. PN 10 Piece1002 3 a14 Polvoroohvlene Random Cooolvmer PPR-C Pioes 40 mm dia. PN 16 Piece1002 3 a15 Polvoroohvlene Random Cooolvmer PPR-C Pioes 40 mm dia. PN 20 Piece1002 3 a16 Polvoroohvlene Random Cooolvmer PPR-C Pioes 50 mm dia. PN 10 Piece1002 (3) a17 Polvoroohvlene Random Cooolvmer PPR-C Pioes 50 mm dia. PN 16 Piece1002 3 a18 Polvoroohvlene Random Cooolvmer PPR-C Pioes 50 mm dia. PN 20 Piece1002 3 a19 Polvoroohvlene Random CODolvmer PPR-C PiDes 63 mm dia. PN 10 Piece1002 3 a20 Polvoroohvlene Random CODolvmer PPR~C Pioes 63 mm dia. PN 16 Piece1002 3 a21 Polvoroohvlene Random Cooolvmer PPR-C Pioes 63 mm dia. PN 20 Piece1002 3 a22 Polvoroohvlene Random Cooolvmer PPR-C Pioes 75 mm dia. PN 10 Piece1002 3 a23 Polvoroohvlene Random Cooolvmer PPR-C Pioes . 75 mm dia. PN 16 Piece1002 3 a24 Polvoroohvlene Random Cooolvmer PPR-C Pioes 75 mm dia. PN 20 Piece1002 3 a25 Polvoroohvlene Random Cooolvmer PPR-C Pioes 100 mm dia. PN 10 Piece1002 3 a26 Polvoroohvlene Random Cooolvmer PPR-C Pioes 100 mm dia. PN 16 Piece1002 3 a27 Polvoroohvlene Random Cooolvmer / PPR-C Pioes 100 mm dia. PN 20 Piece

1002 (3) bl Fittings - Polyprophylene Random Copolymer (PPR-C) 13 mm dia.(Elbow, 1/8 Bend (45 Piecedea.))

1002 (3) b2 Fittings - Polyprophylene Random Copolymer (PPR-C) 20 mm dia.(Elbow, 1/8 Bend (45 Piece

dea.n

Page 18 VOl III

Page 80: Standardized Pay Items of Works for Civil Works Construction for

1002 (3) b3 Fittings - Polyprophylene Random Copolymer (PPR-C) 25 mm dia. (Elbow, 1/8 Bend (45Piecedea. ))

1002 (3) b4 Fittings - Polyprophylene Random Copolymer (PPR-C) 32 mm dia. (Elbow, 1/8 Bend (45Piecedea. ))

1002 (3) b5 Fittings - Polyprophylene Random Copolymer (PPR-C) 40 mm dia. (Elbow, 1/8 Bend (45Piecedea. ))

1002 (3) b6 Fittings - Polyprophylene Random Copolymer (PPR-C) 50 mm dia. (Elbow, 1/8 Bend (45Piecedea.))

1002 (3) b7 Fittings - Polyprophylene Random Copolymer (PPR-C) 65 mm dia. (Elbow, 1/8 Bend (45Piecedea. ))

1002 (3) b8 Fittings - Polyprophylene Random Copolymer (PPR-C) 75 mm dia. (Elbow, 1/8 Bend (45Piecedea.))

1002 (3) b9 Fittings - Polyprophylene Random Copolymer (PPR-C) 100 mm dia. (Elbow, 1/8 Bend (45Piecedea.))

1002 (3) c1 Fittings - Polyprophylene Random Copolymer (PPR-C) 13 mm dia. (Elbow, 1/4 Bend (90Piecedea. ))

1002 (3) c2 Fittings - Polyprophylene Random Copolymer (PPR-C) 20 mm dia. (Elbow, 1/4 Bend (90Piecedea.))

1002 (3) c3 Fittings - Polyprophylene Random Copolymer (PPR-C) 25 mm dia. (Elbow, 1/4 Bend (90Piecedea. ))

1002 (3) c4 Fittings - Polyprophylene Random Copolymer (PPR-C) 32 mm dia. (Elbow, 1/4 Bend (90Piecedea.))

1002 (3) c5 Fittings - Polyprophylene Random Copolymer (PPR-C) 40 mm dia. (Elbow, 1/4 Bend (90Piecedea.))

1002 (3) c6 Fittings - Polyprophylene Random Copolymer (PPR-C) 50 mm dia. (Elbow, 1/4 Bend (90Piecedea.))

1002 (3) c7 Fittings - Polyprophylene Random Copolymer (PPR-C) 65 mm dia. (Elbow, 1/4 Bend (90Piecedea. ))

1002 (3) c8 Fittings - Polyprophylene Random Copolymer (PPR-C) 75 mm dia. (Elbow, 1/4 Bend (90Piecedea.))

1002 (3) c9 Fittings - Polyprophylene Random Copolymer (PPR-C) 100 mm dia. (Elbow, 1/4 Bend (90Piecedea.))

1002 (3) dl Fittinqs - Polvoroohvlene Random Copolymer PPR-C 13 mm dia. Tee Eaual) Piece1002 3 d2 Fittinas - Polvproohvlene Random Copolvmer PPR-C 20 mm dia. Tee Eaual) Piece1002 3 d3 Fittings - Polvoroohvlene Random Cooolymer PPR-C 25 mm dia. Tee Eaual) Piece1002 3 d4 Fittinqs - Polvoroohvlene Random Copolymer PPR-C 32 mm dia. Tee Eaual) Piece1002 (3) d5 Fittings - Polyprophylene Random Copolymer (PPR-C) 40 mm dia. Tee (Equal) Piece1002 (3) d6 Fittinas - Polvoroohvlene Random Cooolvmer PPR-C 50 mm dia. Tee Eaual) Piece1002 (3) d7 Fittinqs - Polvoroohvlene Random Cooolymer PPR-C 65 mm dia. Tee Eaual Piece1002 (3) d8 Fittinas - Polvoroohvlene Random Cooolymer PPR-C 75 mm dia. Tee Eaual Piece1002 (3) d9 Fittings - Polvoroohvlene Random Cooolymer (PPR-C) 100 mm dia. Tee Eaual Piece

Page 19 VOL III

Page 81: Standardized Pay Items of Works for Civil Works Construction for

1002 (3) e1 Fittings - Polyprophylene Random Copolymer (PPR-C) 13 mm x 13 mm dia. Female Threaded Tee Piece

1002 (3) e2 Fittings - Polyprophylene Random Copolymer (PPR-C) 20 mm x 20 mm dia. Female Threaded Tee Piece

1002 (3) e3 Fittings - Polyprophylene Random Copolymer (PPR-C) 25 mm x 25 mm dia. Female Threaded Tee Piece

1002 (3) f1 Fittings - Polyprophylene Random Copolymer (PPR-C) 13 mm x 13 mm dia. Female Elbow Piece

1002 (3) f2 Fittings - Polyprophylene Random Copolymer (PPR-C) 20 mm x 20 mm dia. Female Elbow Piece

1002 (3) f3 Fittings - Polyprophylene Random Copolymer (PPR-C) 25 mm x 25 mm dia. Female Elbow Piece

1002 (3) gl Fittings - Polyprophylene Random Copolymer (PPR-C)20mm dia. x 13mm Tee (Unequal) Piece

dia.

1002 (3) g2 Fittings - Polyprophylene Random Copolymer (PPR-C)25mm dia. x 13mm Tee (Unequal) Piece

dia.

1002 (3) g3 Fittings - Polyprophylene Random Copolymer (PPR-C)25mm dia. x 20mm Tee (Unequal) Piece

dia.

1002 (3) g4 Fittings - Polyprophylene Random Copolymer (PPR-C)32mm dia. x 13mm Tee (Unequal) Piece

dia.

1002 (3) g5 Fittings - Polyprophylene Random Copolymer (PPR-C)32mm dia. x 20mm Tee (Unequal) Piece

dia.

1002 (3) g6 Fittings - Polyprophylene Random Copolymer (PPR-C)32mm dia. x 25mm Tee (Unequal) Piece

dia.

1002 (3) g7 Fittings - Polyprophylene Random Copolymer (PPR-C)40mm dia. x 13mm Tee (Unequal) Piece

dia.

1002 (3) g8 Fittings - Polyprophylene Random Copolymer (PPR-C)40mm dia. x 20mm Tee (Unequal) Piece

dia.

1002 (3) g9 Fittings - Polyprophylene Random Copolymer (PPR-C)40mm dia. x 25mm Tee (Unequal) Piece

dia.

1002 (3) g10 Fittings - Polyprophylene Random Copolymer (PPR-C)40mm dia. x 32mm Tee (Unequal) Piece

dia.

1002 (3) gl1 Fittings - Polyprophylene Random Copolymer (PPR-C)50mm dia. x 13mm Tee (Unequal) Piece

dia.

1002 (3) g12 Fittings - Polyprophylene Random Copolymer (PPR-C)50mm dia. x 20mm Tee (Unequal) Piece

dia.

1002 (3) g13 Fittings - Polyprophylene Random Copolymer (PPR-C)50mm dia. x 25mm Tee (Unequal) Piece

dia.

1002 (3) g14 Fittings - Polyprophylene Random Copolymer (PPR-C)50mm dia. x 32mm Tee (Unequal) Piece

dia.

1002 (3) g15 Fittings - Polyprophylene Random Copolymer (PPR-C)50mm dia. x 40mm Tee (Unequal) Piece

dia.

Page 20 VOl III

Page 82: Standardized Pay Items of Works for Civil Works Construction for

1002 (3) g16 Fittings - Polyprophylene Random Copolymer (PPR-C) 65mm dia. x 32mmTee (Unequal) Piecedia .

.

65mm dia. x 40mm1002 (3) g17 Fittings - Polyprophylene Random Copolymer (PPR-C)dia.

Tee (Unequal) Piece

1002 (3) g18 Fittings - Polyprophylene Random Copolymer (PPR-C) 65mm dia. x 50mmTee (Unequal) Piecedia.

1002 (3) g19 Fittings - Polyprophylene Random Copolymer (PPR-C) 75mm dia. x 32mmTee (Unequal) Piecedia.

1002 (3) g20 Fittings - Polyprophylene Random Copolymer (PPR-C) 75mm dia. x 40mmTee (Unequal) Piecedia.

1002 (3) g21 Fittings - Polyprophylene Random Copolymer (PPR-C) 75mm dia. x 50mmTee (Unequal) Piecedia.

1002 (3) g22 Fittings - Polyprophylene Random Copolymer (PPR-C) 75mm dia. x 65mmTee (Unequal) Piecedia.

1002 (3) g23 Fittings - Polyprophylene Random Copolymer (PPR-C) 100mm dia. x 40mmTee (Unequal) Piecedia.

1002 (3) g24 Fittings - Polyprophylene Random Copolymer (PPR-C) 100mm dia. x 50mmTee (Unequal) Piecedia.

1002 (3) g25 Fittings - Polyprophylene Random Copolymer (PPR-C) 100mm dia. x 65mmTee (Unequal) Piecedia.

1002 (3) g26 Fittings - Polyprophylene Random Copolymer (PPR-C) 100mm dia. x 75mmTee (Unequal) Piecedia.

1002 (3) g27 Fittings - Polyprophylene Random Copolymer (PPR-C) 110 mm x 50 mm xTee (Unequal) Piece110 mm dia.

1002 (3) g28 Fittings - Polyprophylene Random Copolymer (PPR-C) 110 mm x 63 mm xTee (Unequal) Piece110 mm dia.

1002 (3) g29 Fittings - Polyprophylene Random Copolymer (PPR-C) 110 mm x 75 mm xTee (Unequal) Piece110 mm dia.

1002 (3) g30 Fittings - Polyprophylene Random Copolymer (PPR-C) 110 mm x 90 mm xTee (Unequal) Piece110 mm dia.

1002 (3) h1 Fittings - Polyprophylene Random Copolymer (PPR-C) 13 mm dia. Female Threaded Adaptor Piece

1002 (3) h2 Fittings - Polyprophylene Random Copolymer (PPR-C) 20 mm dia. Female Threaded Adaptor Piece

1002 (3) h3 Fittings - Polyprophylene Random Copolymer (PPR-C) 25 mm dia. Female Threaded Adaptor Piece

1002 (3) h4 Fittings - Polyprophylene Random Copolymer (PPR-C) 32 mm dia. Female Threaded Adaptor Piece

1002 (3) h5 Fittings - Polyprophylene Random Copolymer (PPR-C) 40 mm dia. Female Threaded Adaptor Piece

1002 (3) h6 Fittings - Polyprophylene Random Copolymer (PPR-C) 50 mm dia. Female Threaded Adaptor Piece

Page 21 VOL III

Page 83: Standardized Pay Items of Works for Civil Works Construction for

1002 (3) h7 Fittings - Polyprophylene Random Copolymer (PPR-C) 65 mm dia. Female Threaded Adaptor Piece

1002 (3) h8 Fittings - Polyprophylene Random Copolymer (PPR-C) 75 mm dia. Female Threaded Adaptor Piece

1002 (3) h9 Fittings - Polyprophylene Random Copolymer (PPR-C) 100 mm dia. Female Threaded Adaptor Piece

1002 (3) il Fittinas - Polyoroohylene Random Cooolymer PPR-C 13 mm dia. Male Threaded Adaotor Piece1002 3) i2 Fittinas - Polvoroohvlene Random Cooolvmer PPR-C 20 mm dia. Male Threaded Adaotor Piece1002 3 i3 Fittinas - Polvoroohvlene Random Cooolymer PPR-C 25 mm dia. Male Threaded Adaotor Piece1002 3 i4 Fittinas - Polvoroohylene Random Cooolvmer PPR-C 32 mm dia. Male Threaded Adaotor Piece1002 3 is Fittinas - Polvoroohvlene Random Copolymer PPR-C 40 mm dia. Male Threaded Adaotor Piece1002 3 i6 Fittinas - Polvoroohvlene Random Copolymer PPR-C 50 mm dia. Male Threaded Adaotor Piece1002 3 i7 Fittinas - Polvoroohvlene Random Cooolvmer PPR-C 65 mm dia. Male Threaded Adaotor Piece1002 3 i8 Fittinas - Polvoroohvlene Random Copolymer PPR-C 75 mm dia. Male Threaded Adaotor Piece1002 3 i9 Fittinas - Polvoroohvlene Random Copolymer PPR-C 100 mm dia. Male Threaded Adaotor Piece

1002 (3) jl Fittings - Polyprophylene Random Copolymer (PPR-C) 13 mm dia. Female Threaded Union Piece

1002 (3) j2 Fittings - Polyprophylene Random Copolymer (PPR-C) 20 mm dia. Female Threaded Union Piece

1002 (3) j3 Fittings - Polyprophylene Random Copolymer (PPR-C) 25 mm dia. Female Threaded Union Piece

1002 (3) j4 Fittinas - Polyprophylene Random Copolymer (PPR-C) 32 mm dia. Female Threaded Union Piece1002 (3) j5 Fittings - Polyprophylene Random Copolymer (PPR-C) 40 mm dia. Female Threaded Union Piece

1002 (3) j6 Fittings - Polyprophylene Random Copolymer (PPR-C) 50 mm dia. Female Threaded Union Piece

1002 (3) j7 Fittings - Polyprophylene Random Copolymer (PPR-C) 65 mm dia. Female Threaded Union Piece

1002 (3) j8 Fittings - Polyprophylene Random Copolymer (PPR-C) 75 mm dia. Female Threaded Union Piece

1002 (3) j9 Fittings - Polyprophylene Random Copolymer (PPR-C) 100 mm dia. Female Threaded Union Piece1002 3 kl Fittinas - Polvoroohvlene Random Cooolymer PPR-C 13 mm dia. Male Threaded Union Piece1002 3 k2 Fittinas - Polvoroohylene Random Cooolvmer PPR-C 20 mm dia. Male Threaded Union Piece1002 3 k3 Fittinas - Polvoroohvlene Random COpOlymer. PPR-C 25 mm dia. Male Threaded Union Piece1002 3 k4 Fittinas - Polvoroohvlene Random Copolymer PPR-C 32 mm dia. Male Threaded Union Piece1002 3 k5 Fittinas - Polvoroohvlene Random Copolymer PPR-C 40 mm dia. Male Threaded Union Piece1002 3 k6 Fittinas - Polvoroohvlene Random Cooolvmer PPR-C 50 mm dia. Male Threaded Union Piece1002 3 11 Fittinas - Polvoroohvlene Random COpOlymer PPR-C 13 mm dia. End Cao Piece1002 3 12 Fittinas - Polvoroohvlene Random Copolymer (PPR-C) 20 mm dia. End Cao Piece1002 3 13 Fittinas - Polvoroohvlene Random Copolymer PPR-C 25 mm dia. EndCao Piece1002 3 14 Fittinas - Polvoroohvlene Random Cooolymer PPR-C 32 mm dia. End Cao Piece1002 (3) 15 Fittinas - Polvoroohvlene Random Copolymer PPR-C 40 mm dia. End Cao Piece1002 (3) 16 Fittinas - Polvoroohvlene Random Copolymer PPR-C 50 mm dia. End Cao Piece1002 3) 17 Fittinas - Polvoroohylene Random COpOlymer PPR-C 65 mm dia. End Cao Piece1002 (3) 18 Fittinas - Polvoroohvlene Random Copolymer PPR-C 75 mm dia. End Cao Piece1002 3 19 Fittinas - Polvoroohvlene Random Copolymer (PPR-C 100 mm dia. End Cao Piece1002 4 al PVC Pioes blue 13 mm dia. Piece1002 4 a2 PVC Pioes blue 20 mm dia. Piece1002 4 a3 PVC Pioes blue 25 mm dia. Piece1002 4 a4 PVC Pioes (blue) 32 mm dia. Piece

Page 22 VOL III

Page 84: Standardized Pay Items of Works for Civil Works Construction for

1002 4 a5 PVC Pioes (blue 40 mm dia. Piece1002 4 a6 PVC Pines (blue 50 mm dia. Piece1002 4 a7 PVC Pioes blue 65 mm dia. Piece1002 4 a8 PVC Pines blue 75 mm dia. Piece1002 (4) a9 PVC Pines blue) 100 mm dia. Piece

1002 (4) bl PVC Pipes (blue) 13 mm dia. (Elbow, 1/4 Bend (90 Piecedea.))

1002 (4) b2 PVC Pipes (blue) 20 mm dia. (Elbow, 1/4 Bend (90Piecedea.))

1002 (4) b3 PVC Pipes (blue) 25 mm dia. (Elbow, 1/4 Bend (90 Piecedea. ))

1002 (4) b4 PVC Pipes (blue) 32 mm dia. (Elbow, 1/4 Bend (90Piecedea. ))

1002 (4) b5 PVCPipes (blue) 40 mm dia. (Elbow, 1/4 Bend (90 Piecedea,))

1002 (4) b6 PVCPipes (blue) 50 mm dia. (Elbow, 1/4 Bend (90 Piecedee. ))

1002 (4) b7 PVC Pipes (blue) 65 mm dia. (Elbow, 1/4 Bend (90 Piecedea.))

1002 (4) b8 PVC Pipes (blue) 75 mm dia. (Elbow, 1/4 Bend (90 Piecedea.n

1002 (4) b9 PVC Pipes (blue) 100 mm dia. (Elbow, 1/4 Bend (90 Piecedea.n

1002 (4) cl PVC Pipes (blue) 13 mm dia. Female Threaded (Elbow, Piece1/4 Bend (90deg.»

1002 (4) c2 PVC Pipes (blue) 20 mm dia. Female Threaded (Elbow, Piece1/4 Bend (90deg.»

1002 (4) c3 PVC Pipes (blue) 25 mm dia. Female Threaded (Elbow,Piece1/4 Bend (90deg.»

1002 (4 dl PVCPines blue 13 mm dia. PVC Tee Eaual Piece1002 (4 d2 PVC Pioes blue 20 mm dia. PVC Tee Eaual Piece1002 4 d3 PVC Pioes blue 25 mm dia. PVC Tee Eaual Piece1002 4 d4 PVC Pines blue 32 mm dia. PVC Tee Eaual Piece1002 4 d5 PVC Pioes blue 40 mm dia. PVC Tee Eaual Piece1002 4 d6 PVC Pines Iblue 50 mm dia. PVC Tee Eaual Piece1002 4 el PVC Pines blue 13 mm dia. PVC Female Threaded Tee Piece1002 4 e2 PVC Pioes 'blue 20 mm dia. PVC Female Threaded Tee Piece1002 4 e3 PVC Pines (blue 25 mm dia. PVC Female Threaded Tee Piece

Page 23 VOL III

Page 85: Standardized Pay Items of Works for Civil Works Construction for

1002 (4) f1 PVCPipes (blue)20 mm dia. x 13 mm PVC Tee Reducer (Unequal Piece

dia.

1002 (4) f2 PVCPipes (blue)25 mm dia. x 20 mm PVC Tee Reducer (Unequal Piece

dia.

1002 (4) f3 PVCPipes (blue)32 mm dia. x 20 mm PVC Tee Reducer (Unequal Piece

dia.

1002 (4) f4 PVCPipes (blue)32 mm dia. x 25 mm PVC Tee Reducer (Unequal Piece

dia.

1002 (4) f5 PVCPipes (blue)40 mm dia x 20 mm PVC Tee Reducer (Unequal Piece

dia.

1002 (4) f6 PVC Pipes (blue)40 mm dia. x 25 mm PVC Tee Reducer (Unequal Piece

dia.

1002 (4) f7 PVCPipes (blue)50 mm dia. x 25 mm PVC Tee Reducer (Unequal Piece

dia.

1002 (4) f8 PVCPipes (blue)50 mm dia. x 32 mm PVC Tee Reducer (Unequal Piece

dia.

1002 (4) f9 PVC Pipes (blue)50 mm dia. x 40 mm PVC Tee Reducer (Unequal Piece

dia.

1002 (4) 91 PVCPipes (blue)20 mm dia. x 13 mm PVC Elbow Reducer Piece

dia.

1002 (4) 92 PVC Pipes (blue)25 mm dia. x 13 mm PVC Elbow Reducer Piece

dia.

1002 (4) 93 PVCPipes (blue)25 mm dia. x 20 mm PVC Elbow Reducer Piece

dia.1002 4 h1 PVCPioes blue 13 mm dia. PVC Socket! Couolina Piece1002 4 h2 PVC Pioes blue 20 mm dia. PVC Socke Couolina Piece1002 4 h3 PVCPioes blue 25 mm dia. PVC Socke Couolino Piece1002 4 h4 PVCPioes blue 32 mm dia. PVC Socke Couolino Piece1002 4 h5 PVCPioes blue 40 mm dia. PVC Socke Couolina Piece1002 (4) h6 PVCPioes (blue 50 mm dia. PVC Socket)Couolina Piece

1002 (4) i1 PVC Pipes (blue)20 mm dia. x 13 mm PVC Reducer Piece

dia.

1002 (4) i2 PVC Pipes (blue)25 mm dia. x 20 mm PVC Reducer Piece

dia.

1002 (4) i3 PVCPipes (blue)32 mm dia. x 25 mm PVC Reducer Piece

dia.

1002 (4) i4 PVC Pipes (blue)40 mm dia. x 32 mm PVC Reducer Piece

dia.

1002 (4) is PVCPipes (blue)50 mm dia. x 40 mm PVC Reducer Piece

dia.1002 (4) j1 PVCPipes (blue) 13 mm dia. PVC Male Threaded Adaptor Piece

1002 (4) j2 PVC Pipes (blue) 20 mm dia. PVC Male Threaded Adaptor Piece

Page 24 VOL III

Page 86: Standardized Pay Items of Works for Civil Works Construction for

1002 4 j3 PVC Pipes (blue 25 mm dia. PVC Male Threaded Adaptor Piece1002 4 i4 PVC Pipes (blue 32 mm dia. PVC Male Threaded Adaptor Piece1002 4 j5 PVC Pipes (blue 40 mm dia. PVC Male Threaded Adaptor Piece1002 (4) j6 PVC PiDes (blue 50 mm dia. PVC Male Threaded Adaptor Piece1002 (4) k1 PVC Pipes (blue) 13 mm dia. Female Threaded Adaptor Piece1002 (4) k2 PVC Pipes (blue) 20 mm dia. Female Threaded Adaptor Piece1002 (4) k3 PVC Pipes (blue) 25 mm dia. Female Threaded Adaptor Piece1002 (4) 11 PVC Pipes (blue 13 mm dia. Cap Piece1002 (4) 12 PVC Pipes (blue) 20 mm dia. Cap Piece1002 4 13 PVC PiDes (blue) 25 mm dia. Cap Piece1002 5 Plumbina Fixtures Lump Sum1002 5 a1 Water Closet Elonaated Complete Tank Type Set1002 5 a2 Water Closet Elongated-LComplete Flush Type Set1002 5 a3 Water Closet, Elongated, Automatic Flush Valve, Complete Sensor Type Set1002 5 a4 Water Closet, Round Front Complete Tank Type Set1002 5 as Water Closet, Round Front Complete Flush Type Set1002 5 a6 Water Closet, Round Front Automatic Flush Valve Complete Sensor Type Set1002 5 b1 Urinal, Flush Valve, Complete Push Button Type Set1002 5 b2 Urinal, Flush Valve, ComJl!ete Lever Arm Type Set1002 5) b3 Urinal. Automatic Flush Valve. Complete Sensor Type Set1002 5) c1 Kitchen Sink Complete Stainless Set1002 (5) c2 Kitchen Sink Complete Aluminum Set1002 (5) d Scrub Up Sink ComJl!ete Set1002 5 e Slop Sink, Complete Set1002 5 f1 Lavatory, Wall Huna. Complete Manually Operated Set1002 5 f2 Lavatory. Wall Hun~ Complete Sensor TYpe Set1002 5 g3 Lavatory, Counter Top/Under Counter, Complete Manually Operated Set1002 5 g4 Lavatory. Counter TQQ[Under Counter. Complete Sensor TYpe Set1002 5 h1 Floor Drain Plates 50 mm dia. Stainless Set1002 5 h2 Floor Drain Plates 75 mm dia. Stainless Set1002 5 h3 Floor Drain Plates 100 mm dia. Stainless Set1002 5 h4 Floor Drain Plates 50 mm dia. Brass Set1002 5 h5 Floor Drain Plates 75 mm dia. Brass Set1002 5 h6 Floor Drain Plates 100 mm dia. Brass Set1002 5 i Toilet Soap Holder Piece1002 5 j Liauid Soap Dispenser Piece1002 5 k Toilet Tissue Holder Piece1002 5) I Toilet Tissue Dispenser Piece1002' 5) m Bidet Piece1002 5) n Stainless Steel Grab Bar 40mm dia. Linear Meter

Page 25 VOLUME III

Page 87: Standardized Pay Items of Works for Civil Works Construction for

1002 5 0 Shower Head/Shower Valve Set1002 5 p Facial Mirror Square Meter1002 5 ~ Faucet Piece1002 5 r Hose Bibb Piece1002 5 sl Water Meter 13 mm dia. Piece1002 5 s2 Water Meter 20 mm dia. Piece1002 5 s3 Water Meter 25 mm dia. Piece I

1002 5 s4 Water Meter 32 mm dia. Piece1002 6 Cold Water Lines Lump Sum1002 7 Hot Water Lines Lump Sum

1003 (1) a2 Ceiling 4.5 mm Wood Frame Fiber Cement Board Square Meters

1003 (1) b1 Ceiling 4.5 mm Metal Frame Marine Plywood Square Meters

1003 (1) b2 Ceiling 4.5 mm Wood Frame Marine Plywood Square Meter~

1003 (1) c1 Ceiling 6 mm Metal Frame Marine Plywood Square Meters

1003 (1) c2 Ceiling 6 mm Wood Frame Marine Plywood Square Meters

1003 (1) d1 Ceiling 6 mm Metal Frame Ordinary Plywood . Square Meters

1003 (1) d2 Ceiling 6 mm Wood Frame Ordinary Plywood Square Meters

1003 (1) e1 Ceiling Metal Frame Gypsum Board Square Meters

1003 (1) e2 Ceiling Metal Frame Prepainted Metal Panel Square Meters

1003 (1) e3 Ceiling Metal Frame Aluminun Metal Cladding Square Meters

1003 (2) a1 Wall 4.5 mm Metal Frame Fiber Cement Board Square Meters

1003 (2) a2 Wall 4.5 mm Wood Frame Fiber Cement Board Square Meters

1003 (2) b1 Wall 6mm Metal Frame Fiber Cement Board Square Meters

1003 (2) b2 Wall 6mm Wood Frame Fiber Cement Board Square Meters

Page 26 VOLUME III

Page 88: Standardized Pay Items of Works for Civil Works Construction for

1003 (2) c1 Wall 4.5 mm Metal Frame Marine Plywood Square Meters

1003 (2) c2 Wall 4.5 mm Wood Frame Marine Plywood Square Meters,

1003 (2) d1 Wall 6mm Metal Frame Marine Plywood Square Meters

1003 (2) d2 Wall 6mm Wood Frame Marine Plywood Square Meters

1003 (2) e1 Wall 6mm Metal Frame Ordinary Plywood Square Meters

1003 (2) e2 Wall 6mm Wood Frame Ordinary Plywood Square Meters

1003 (2) d Wall Aluminun Metal Cladding Square Meters

1003 3) a1 Cabinets Sauare Meters

1003 3\ a2 Cabinets Piece

1003 4 a1 Roof Frame Wood Piece

1003 (4) a2 Roof Frame Wood Meter

1003 (4) b1 Floor Frame Wood Piece

1003 4 b2 Floor Frame Wood Meter

1003 4 c1 Floorina Wood Piece

1003 4 c2 Floorina Wood Meter

1003 4 d1 Wall Frame Wood Piece

1003 4 d2 Wall Frame Wood Meter

1003 5 a1 Fascia Board 19 mm Fiber Cement Board Meter

1003 5 a2 Fascia Board 25 mm Lumber Meter

1003 5 a3 Fascia Board Metal Kiloqram

1003 6 a1 Phenolic Board Piece

1003 6 a2 Phenolic Board Sauare Meters

1003 7 a1 Mouldinq Wood Meter

1003 7 a2 Mouldina Concrete Meter

1003 8 Pressurized Laminated Wood Particles Sauare Meters

Page 27 VOL III

Page 89: Standardized Pay Items of Works for Civil Works Construction for

1004 2 b Finishino Hardware Latches Set1004 2 c Finishina Hardware Bolts Set1004 2 d Finishino Hardware Door Closer Set1004 2 e Finishino Hardware Knobs Set1004 2 f Finishino Hardware Handles Set1004 2 a Finishina Hardware Hinqes Set1004 2 h Finishino Hardware Ladder Set I

1004 2 i Finishino Hardware Grab Bar Set1004 3 Facial Mirror Sauare Meter

Hollow Steel DoorFlush DoorGrille DoorSteel Louver DoorFire Rated Fire Exit Steel Door

Aluminum Glass WindowsAluminum Glass WindowsAluminum Glass WindowsAluminum Glass Windows

Page 28

S uare MeterS uare MeterS uare MeterS uare MeterS uare Meter

VOL III

Page 90: Standardized Pay Items of Works for Civil Works Construction for

1012 a Float Glass 5.6mm1012 b Ordina window & Sheet Glass 5.6mm1012 c1 Plate Glass 8mm1012 c2 Plate Glass 10mm1012 c3 Plate Glass 12mm1012 d1 Tern ered Glass Doors lOmm1012 d2 Tern ered Glass Doors 12mm1012 e1 Tern ered Glass Windows 8mm1012 e2 Tern ered Glass Windows lOmm1012 f1 Tern ered Glass Walls Barriers etc. 6mm1012 f2 Tern ered Glass Walls Barriers etc. 8mm1012 f3 Tern ered Glass Walls Barriers etc. 10mm

1010 (1) Frames

a Doorsb Doorsc Doorsc Window Sashes

Page 29

. Jambs, Sills, Head,Transoms and Mullions

FlushWood PanelGlass Panel

Set

VOL III

Page 91: Standardized Pay Items of Works for Civil Works Construction for

10131013101310131013 21013 21013 3

b Fabricated Metal RoofinFabricated Metal RoofinFabricated Metal RoofinFabricated Metal RoofinFabricated Metal RoofinFabricated Metal RoofinRoof Ventilators

Page 30

Long Span

Lon S anEaves

Linear MeterLinear MeterLinear MeterLinear MeterLinear Meter

PieceEach

S uare MeterLinear MeterLinear MeterLinear MeterLinear MeterLinear MeterLinear Meter

Each

Square Meter

S uare MeterS uare Meter

VOL III

Page 92: Standardized Pay Items of Works for Civil Works Construction for

1017 al Roof Drain with Strainer Set

1017 a2 Roof Drain with Strainer Set I

1017 a3 Roof Drain with Strainer Set

1017 a4 Roof Drain with Strainer Set I

1017 bl Cano Drain with Strainer Set

1017 b2 Cano Drain with Strainer Set

1017 b3 Cano Drain with Strainer Set

1017 b4 Cano Drain with Strainer Set

1017 3 c1 Gutter Drain with Strainer Set

1017 3 c2 Gutter Drain with Strainer Set

1017 3 c3 Gutter Drain with Strainer Set

101810181018 31018 41018 51018 51018 51018 51018 6

abcd

Page 31

S uare MeterS uare MeterS uare MeterS uare Meter

VOL III

Page 93: Standardized Pay Items of Works for Civil Works Construction for

Corridors and Stair Landin sTreads and Risers etc.Rooms and others

with Floor

PlainTrowelled Finish

S uare MeterS uare Meter

Square Meter

Square Meter

S uare MeterS uare MeterS uare MeterS uare Meter

Page 32 VOL III

Page 94: Standardized Pay Items of Works for Civil Works Construction for

ITEM 1032 - PAINTING, VARNISHING AN[)QTHER RELATED WORKS.PetN1032103210321032103210321032

Page 33 VOLUME III

Page 95: Standardized Pay Items of Works for Civil Works Construction for

Page 34 VOLUME III

Page 96: Standardized Pay Items of Works for Civil Works Construction for

Page 35 VOLUME III

Page 97: Standardized Pay Items of Works for Civil Works Construction for

1046 (2) a CHB Non Load Bearinq (includina Reinforcinq Steel) 100 mm Sauare Meter1046 (2) b CHB Non Load Bearinq (includina Reinforcina Steel) 150 mm Sauare Meter1046 (3) Louver Blocks Sauare Meter

1047 Structural Steel Roof Framin1047 a Structural Steel Roof Framin1047 b Structural Steel Trusses1047 c Structural Steel Purl ins1047 a Metal Structure Accessories Bolts1047 b Metal Structure Accessories Sa rods1047 c Metal Structure Accessories Turnbuckle1047 d Metal Structure Accessories Cross Bracin1047 Metal Structure Accessories Cross Bracin1047 a Metal Structure Accessories Steel Plates1047 b Metal Structure Accessories Steel Plates

ITEM 1050 - NON..SHRINK.GROUT*Non-shrink grout shall not be measured and paid for separately, but the cost thereof shall be considered as included in the contract unit price of the items where called for.

Page 36

uare Meteruare Meteruare Meteruare Meter

VOLUME III

Page 98: Standardized Pay Items of Works for Civil Works Construction for

abc

StandardBallusterPara et

MeterMeterMeterMeterMeterMeterMeter

IT;M1052-_.Si105i7IT Untreated Timber Piles furnished Meter1052 (2) Treated Timber Piles preservative furnished Meter1052 13 Steel H-Piles. furnished Meter1052 4 a Precast Concrete Piles furnished 400x400 mm Meter1052 4 b Precast Concrete Piles furnished 450x450 mm Meter1052 5 a Precast. Prestresssed Concrete Piles. furnished 400x400 mm Meter1052 5 b Precast. Prestresssed Concrete Piles. furnished 450x450 mm Meter1052 6 Structural Steel Sheet Piles furnished Meter1052 7 Precast Concrete Sheet Piles. furnished Meter1052 8 Untreated Timber Piles. driven Meter1052 9) Treated Timber Piles. driven Meter

1052 10 Steel H-Piles driven Meter1052 11 Steel Pioes Piles Meter1052 12 Structural Steel Sheet Piles driven Meter1052 13 Precast Concrete Sheet Piles driven Meter1052 14 Precast Concrete Piles, driven Meter1052 15 Precast Prestresssed Concrete Piles driven Meter1052 16 Test Piles furnished and driven Meter1052 17 a Concrete Piles cast in Drilled Holes 0.80 Meter1052 17 b Concrete Piles cast in Drilled Holes 1.00 Meter105207 c Concrete Piles cast in Drilled Holes 1.20 Meter1052 17 d Concrete Piles cast in Drilled Holes 1.50 Meter1052 17 e Concrete Piles cast in Drilled Holes 1.80 Meter1052 17 f Concrete Piles cast in Drilled Holes 2.00 Meter1052 17 a Concrete Piles cast in Drilled Holes 2.50 Meter1052 17 h Concrete Piles cast in Drilled Holes 2.80 Meter1052 (17 i Concrete Piles cast in Drilled Holes 3.00 Meter1052 (18 Concrete Piles cast in Steel Shells 400-500 mm dia. Meter1052 (19 Concrete Piles cast in Steel Pioes 400-500 mm dia. Meter

Page 37 VOLUME III

Page 99: Standardized Pay Items of Works for Civil Works Construction for

1052 (20 Pile Shoes Each1052 (21 Splices Each1052 22 Load Tests Each1052 23 a Bored Piles 0.80 Meter1052 23 b Bored Piles 1.00 Meter \1052 (23 c Bored Piles 1.20 Meter1052 (23 d Bored Piles 1.50 Meter I1052 23 e Bored Piles 1.80 Meter1052 23 f Bored Piles 2.00 Meter1052 23 f Bored Piles 2.50 Meter1052 23 f Bored Piles 2.80 Meter1052 (23) a Bored Piles 3.00 Meter1052 (24 a Permanent Casina 0.80 Meter1052 24 b Permanent Casina 1.00 Meter1052 24 c Permanent Casina 1.20 Meter1052 24 d Permanent Casina 1.50 Meter1052 24 e Permanent Casina 1.80 Meter1052 24 f Permanent Casina 2.00 Meter1052 24 a Permanent Casina 2.50 Meter1052 24 h Permanent Casina 2.80 Meter1052 24 i Permanent Casina 3.00 Meter1052 25 Solicina of R.C. Piles with Eooxy Kiloaram

·1052 26 SDlicina of R.C. Piles with EDOXY Each1052 27 a Pile Intearitv Testina Crosshole-Sonic Each1052 27 b Pile Intearitv Testina Low Strain Each1052 28 Hiah Strain Dynamic Testina (P.D.A) Each1052 29 Micro Piles 0.20 Meter1052 30 Permanent Casina (Micro Piles) 0.20 Kiloaram

IXm

1053 (1) a Jet Groutina 0.80 Meter1053 (1) b Jet Groutina 1.00 Meter1053 (1) c Jet Groutina 1.20 Meter

PART D - ELECTRICAL

~OXES -. y

:~umb ~.1100 (1) al Riaid Steel Conduit (RSCT 15 mm dia. x 3m

Page 38 VOLUME III

Page 100: Standardized Pay Items of Works for Civil Works Construction for

1100 1 a2 Riaid Steel Conduit RSC 20 mm dia x 3m Lenqth

1100 1 a3 Riaid Steel Conduit RSC 25 mm dia x 3m Lenath

1100 1 a4 Riqid Steel ConduittRSC 32 mm dia x 3m Lenqth

1100 1 a5 Riaid Steel Conduit RSC 40 mm dia x 3m LenQth

1100 1 a6 Riaid Steel Conduit RSC 50 mm dia x 3m Lenath

1100 1 a7 Riaid Steel Conduit RSC 65 mm dia x 3m LenQth

1100 1 a8 Riaid Steel Conduit RSC 80 mm dia x 3m Lenath

1100 1 a9 Riaid Steel Conduit RSC 90 mm dia x 3m Lenath

1100 1 al0 Riaid Steel Conduit RSC 100 mm dia x 3m LenQth

1100 1 all Riaid Steel Conduit RSC 125 mm dia x 3m Lenath

1100 1 a12 Riaid Steel Conduit (RSC) 150 mm dia x 3m LenQth

1100 1 bl Intermediate Metal Conduit IMC 15 mm dia. x 3m Lenath

1100 1 b2 Intermediate Metal Conduit IMC 20 mm dia x 3m Lenqth

1100 1 b3 Intermediate Metal Conduit IMC 25 mm dia x 3m Lenath

1100 1 b4 Intermediate Metal Conduit IMC 32 mm dia x 3m Lenath

1100 1 b5 Intermediate Metal Conduit IMC 40 mm dia x 3m Lenath

1100 1 b6 Intermediate Metal Conduit IMC 50 mm dia x 3m Lenath

1100 1 b7 Intermediate Metal Conduit IMC 65 mm dia x 3m Lenath

1100 1 b8 Intermediate Metal Conduit IMC 80 mm dia x 3m Lenqth

1100 1 b9 Intermediate Metal Conduit IMC 90 mm dia x 3m Lenath

1100 1 bl0 Intermediate Metal Conduit (IMC) 100 mm dia x 3m LenQth

1100 1 cl Flexible Metal Conduit 15 mm dia. x 3m Meter

1100 1 c2 Flexible Metal Conduit 20 mm dia x 3m Meter

1100 1 c3 Flexible Metal Conduit 25 mm dia x 3m Meter

1100 1 c4 Flexible Metal Conduit 32 mm dia x 3m Meter

1100 1 c5 Flexible Metal Conduit 40 mm dia x 3m Meter

1100 1 c6 Flexible Metal Conduit 50 mm dia x 3m Meter

1100 1 c7 Flexible Metal Conduit 65 mm dia x 3m Meter

1100 1 c8 Flexible Metal Conduit 80 mm dia x 3m Meter

1100 1 c9 Flexible Metal Conduit 90 mm dia x 3m Meter

1100 1 ciO Flexible Metal Conduit 100 mm dia x 3m Meter

1100 1 dl Electrical Metallic Tubina EMT 15 mm dia. x 3m Lenath

1100 1 d2 Electrical Metallic Tubina EMT 20 mm dia x 3m LenQth

1100 1 d3 Electrical Metallic Tubina EMT 25 mm dia x 3m Lenath

1100 1 d4 Electrical Metallic Tubina EMT 32 mm dia x 3m Lenath

1100 1 d5 Electrical Metallic Tubina EMT 40 mm dia x 3m Lenath

1100 1 d6 Electrical Metallic Tubina EMT 50 mm dia x 3m Lenath

1100 1 d7 Electrical Metallic Tubina EMT 65 mm dia x 3m Lenqth

1100 1 d8 Electrical Metallic Tubina EMT 80 mm dia x 3m Lenath

1100 1 d9 Electrical Metallic Tubina EMT 90 mm dia x 3m Lenath

1100 1 dl0 Electrical Metallic Tubina EMT 100 mm dia x 3m Lenqth

1100 1 el Riaid Tvee Flexible Non-Metallic Conduit 10 mm dia. x 3m Meter

1100 1 e2 Riaid Tvee Flexible Non-Metallic Conduit 15 mm dia. x 3m Meter

Page 39 VOL III

Page 101: Standardized Pay Items of Works for Civil Works Construction for

1100 (1 e3 Riqid Type Flexible Non-Metallic Conduit 20 mm dia x 3m Meter1100 (1 e4 Riaid Type Flexible Non-Metallic Conduit 25 mm dia x 3m Meter1100 (1 e5 Riqid Type Flexible Non-Metallic Conduit 32 mm dia x 3m Meter1100 1 e6 Riaid Type Flexible Non-Metallic Conduit 40 mm dia x 3m Meter1100 1 e7 Riaid Type Flexible Non-Metallic Conduit 50 mm dia x 3m Meter1100 1 f1 Polyvinyl Chloride Pipes PVC uPVC) 20 mm dia x 3m Meter1100 1) f2 PolYVinyl Chloride Pipes PVC uPVC) 25 mm dia x 3m Meterl1100 1) f3 PolYVinyl Chloride Pipes PVC uPVC) 32 mm dia x 3m Meter1100 1 f4 PolYVinvl Chloride Pipes PVC uPVC 40 mm dia x 3m Meter1100 1 f5 Polyvinyl Chloride Pipes PVC uPVC 50 mm dia x 3m Meter1100 1 f6 PolYVinyl Chloride Pipes PVC uPVC 63 mm dia x 3m Meter1100 1 f7 PolYVinyl Chloride Pipes PVC uPVC 75 mm dia x 3m Meter1100 1 f8 Polyvinyl Chloride Pipes PVC uPVC 90 mm dia x 3m Meter1100 1 f9 Polyvinyl Chloride Pipes PVC uPVC 100 mm dia x 3m Meter1100 1 fl0 PolYVinyl Chloride Pipes PVC uPVC 110 mm dia x 3m Meter1100 1 f11 PolYVinyl Chloride Pipes (PVC/uPVC) 160 mm dia x 3m Meter1100 2 al Conduit Couplinq 15 mm dia. RSC Piece1100 2 a2 Conduit Couplinq 20 mm dia RSC Piece1100 2 a3 Conduit Couplinq 25 mm dia. RSC Piece1100 2 a4 Conduit Couplinq 32 mm dia. RSC Piece1100 2 as Conduit Coupling 40 mm dia. RSC Piece1100 2 a6 Conduit Couplinq 50 mm dia. RSC Piece1100 2 a7 Conduit Couplina 65 mm dia. RSC Piece1100 2 a8 Conduit Coupling 80 mm dia. RSC Piece1100 2 a9 Conduit Couplinq 90 mm dia. RSC Piece1100 2 al0 Conduit Couplina 100 mm dia. RSC Piece1100 2 all Conduit Couplina 125 mm dia RSC Piece1100 (2) a12 Conduit Couplinq 150 mm dia RSC Piece1100 (2) bl Conduit Couplina 15 mm dia. IMC Piece1100 2 b2 Conduit Couplinq 20 mm dia IMC Piece1100 2 b3 Conduit Couplinq 25 mm dia. IMC Piece1100 2 b4 Conduit Couplina 32 mm dia. IMC Piece1100 2 b5 Conduit Couplina 40 mm dia. IMC Piece1100 2 b6 Conduit Couplina 50 mm dia. IMC Piece1100 2 b7 Conduit Coupling 65 mm dia. IMC Piece1100 2 b8 Conduit Couplinq 80 mm dia. IMC Piece1100 2 b9 Conduit Couplina 90 mm dia. IMC Piece1100 2 bl0 Conduit Coupling 100 mm dia. IMC Piece1100 2 cl Conduit Couplina 15 mm dia. EMT Screw Type Piece1100 2 c2 Conduit Couplinq 20 mm dia EMT Screw Type Piece1100 2 c3 Conduit Couplinq 25 mm dia. EMT Screw Type Piece1100 2 c4 Conduit Couplinq 32 mm dia. EMT Screw Type Piece1100 2 c5 Conduit Couplina 40 mm dia. EMT Screw Type Piece

Page 40 VOL III

Page 102: Standardized Pay Items of Works for Civil Works Construction for

1100 (2 c6 Conduit Couolina 50 mm dia. EMT Screw Tvoe Piece

1100 (2 c7 Conduit Couolina 65 mm dia. EMT Screw Tvoe Piece

1100 (2 c8 Conduit Couolina 80 mm dia. EMT Screw Tvoe Piece

1100 (2 c9 Conduit Couolina 90 mm dia. EMT Screw Tvoe Piece

1100 2 c10 Conduit Couolina 100 mm dia. EMT Screw Tvoe Piece

1100 2 d1 PVC uPVC Couolina 20 mm dia. Piece

1100 2 d2 PVC uPVC Couolina 25 mm dia. Piece

1100 2 d3 PVC/uPVC Couolina 32 mm dia. Piece

1100 2 . d4 PVC uPVC Couolina 40 mm dia. Piece

1100 2 d5 PVC uPVC Couolina 50 mm dia. Piece

1100 2 d6 PVC uPVC Couolina 63 mm dia. Piece

1100 2 d7 PVC uPVC Couolina 75 mm dia. Piece

1100 2 d8 PVC uPVC Couolina 90 mm dia. Piece

1100 2 d9 PVC/uPVC Couolina 100 mm dia. Piece

1100 2 d10 PVC/uPVC Couolina 110 mm dia. Piece

1100 2 d11 PVC/uPVC Couolina 160 mm dia. Piece

1100 3 a1 Locknut & Bushina 15 mm dia. RSC Pair

1100 3 a2 Locknut & Bushina 20 mm dia RSC Pair

1100 3 a3 Locknut & Bushina 25 mm dia. RSC Pair

1100 3 a4 Locknut & Bushina 32 mm dia. RSC Pair

1100 3 as Locknut & Bushina 40 mm dia. RSC Pair

1100 3 a6 Locknut & Bushina 50 mm dia. RSC Pair

1100 3 a7 Locknut & Bushina 65 mm dia. RSC Pair

1100 3 a8 Locknut & Bushina 80 mm dia. RSC Pair

1100 3 a9 Locknut & Bushina 90 mm dia. RSC Pair

1100 3 ala Locknut & Bushina 100 mm dia. RSC Pair

1100 '3 all Locknut & Bushina 125 mm dia. RSC Pair

1100 '3 a12 Locknut & Bushina 150 mm dia. RSC Pair

1100 3 b1 Locknut & Bushina 15 mm dia. IMC Pair

1100 3 b2 Locknut & Bushina 20 mm dia IMC Pair

1100 3 b3 Locknut & Bushina 25 mm dia. IMC Pair

1100 3 b4 Locknut & Bushina 32 mm dia. IMC Pair

1100 3 b5 Locknut & Bushina 40 mm dia. IMC Pair

1100 3 b6 Locknut & Bushina 50 mm dia. IMC Pair

1100 3 b7 Locknut & Bushina 65 mm dia. IMC Pair

1100 3 b8 Locknut & Bushina 80 mm dia. IMC Pair

1100 3 b9 Locknut & Bushina 90 mm dia. IMC Pair

1100 3 blO Locknut & Bushina 100 mm dia. IMC Pair

1100 3 c1 PVC uPVC Adaoter 20 mm dia. Piece

1100 3 c2 PVC uPVC Adaoter 25 mm dia. Piece

1100 3 c3 PVC uPVC Adaoter 32 mm dia. Piece

1100 (3 c4 PVC uPVC Adaoter 40 mm dia. Piece

1100 (3 c5 PVC uPVC Adaoter 50 mm dia. Piece

Page 41 VOL III

Page 103: Standardized Pay Items of Works for Civil Works Construction for

1100 (3 c6 PVC uPVC Adaoter 63 mm dia. Piece1100 (3 c7 PVC uPVC Adaoter 75 mm dia. Piece1100 (3 c8 PVC uPVC Adaoter 90 mm dia. Piece1100 (3 c9 PVC uPVC Adaoter 100 mm dia. Piece1100 (3 c10 PVC uPVC Adaoter 110 mm dia. Piece

,1100 (3) cll PVC/uPVC Adaoter 160 mm dia. Piece .1100 (4) al Conduit Elbow 15 mm dia. x 90 deg. RSC Piece

1100 (4) a2 Conduit Elbow 20 mm dia. x 90 deg. RSC Piece

1100 (4) a3 Conduit Elbow 25 mm dia. x 90 deg. RSC Piece

1100 (4) a4 Conduit Elbow 32 mm dia. x 90 deg. RSC Piece

1100 (4) as Conduit Elbow 40 mm dia. x 90 deg. RSC Piece

1100 (4) a6 Conduit Elbow 50 mm dia. x 90 deg. RSC Piece

1100 (4) a7 Conduit Elbow 65 mm dia. x 90 deg. RSC Piece

1100 (4) a8 Conduit Elbow 80 mm dia. x 90 deg. RSC Piece

1100 (4) a9 Conduit Elbow 90 mm dia. x 90 deg. RSC Piece

1100 (4) al0 Conduit Elbow 100 mm dia. x 90 deg. RSC Piece

1100 (4) all Conduit Elbow 125 mm dia. x 90 deg. RSC Piece

1100 (4) a12 Conduit Elbow 150 mm dia. x 90 deg. RSC Piece

1100 (4) b1 Conduit Elbow 15 mm dia. x 90 deg. IMC Piece

1100 (4) b2 Conduit Elbow 20 mm dia. x 90 deg. IMC Piece

1100 (4) b3 Conduit Elbow 25 mm dia. x 90 deg. IMC Piece

1100 (4) b4 Conduit Elbow 32 mm dia. x 90 deg. IMC Piece

1100 (4) b5 Conduit Elbow 40 mm dia. x 90 deg; IMC Piece

1100 (4) b6 Conduit Elbow 50 mm dia. x 90 deg. IMC Piece

Page 42 VOL III

Page 104: Standardized Pay Items of Works for Civil Works Construction for

1100 (4) b7 Conduit Elbow 65 mm dia. x 90 deg. IMC Piece

1100 (4) b8 Conduit Elbow 80 mm dia. x 90 deg. IMC Piece

1100 (4) b9 Conduit Elbow 90 mm dia. x 90 deg. IMC Piece

1100 (4) b10 Conduit Elbow 100 mm dia. x 90 deg. IMC Piece

1100 (4) c1 Conduit Elbow 15 mm dia. x 90 deg. EMT Piece

1100 (4) c2 Conduit Elbow 20 mm dia. x 90 deg. EMT Piece

1100 (4) c3 Conduit Elbow 25 mm dia. x 90 deg. EMT Piece

1100 (4) c4 Conduit Elbow 32 mm dia. x 90 deg. EMT Piece

1100 (4) c5 Conduit Elbow 40 mm dia. x 90 deg. EMT Piece

1100 (4) c6 Conduit Elbow 50 mm dia. x 90 deg. EMT Piece

1100 (4) c7 Conduit Elbow 65 mm dia. x 90 deg. EMT Piece

1100 (4) c8 Conduit Elbow 80 mm dia x 90 deg. EMT Piece

1100 (4) c9 Conduit Elbow 90 mm dia x 90 deg. EMT Piece

1100 (4) c10 Conduit Elbow 100 mm dia x 90 deg. EMT Piece

1100 (4) d1 PVC/uPVC Elbow 20 mm dia. x 90 deg. Piece

1100 (4) d2 PVC/uPVC Elbow 25 mm dia. x 90 deg. Piece

1100 (4) d3 PVC/uPVC Elbow 32 mm dia . x 90 deg. Piece

1100 (4) d4 PVC/uPVC Elbow 40 mm dia. x 90 deg. Piece

1100 (4) d5 PVC/uPVC Elbow 50 mm dia. x 90 deg. Piece

1100 (4) d6 PVC/uPVC Elbow 63 mm dia. x 90 deg. Piece

1100 (4) d7 PVC/uPVC Elbow 75 mm dia. x 90 deg Piece

Page 43 VOL III

Page 105: Standardized Pay Items of Works for Civil Works Construction for

1100 (4) d8 PVCjuPVC Elbow 90 mm dia. x 90 deg. Piece

1100 (4) d9 PVCjuPVC Elbow 100 mm dia. x 90 deg. Piece

1100 (4) dl0 PVCjuPVC Elbow 110 mm dia x 90 deg. Piece ,

1100 (4) d11 PVCjuPVC Elbow 160 mm dia x 90 deg. Piece

1100 (5) al Straiqht Connector 15 mm dia. EMT Piece1100 (5 a2 Straiaht Connector 20 mm dia EMT Piece1100 5 a3 Straiaht Connector 25 mm dia. EMT Piece1100 5 a4 Straiqht Connector 32 mm dia. EMT Piece1100 5 as Straiqht Connector 40 mm dia. EMT Piece1100 5 a6 Straiaht Connector 50 mm dia. EMT Piece1100 5 a7 Straiaht Connector 65 mm dia. EMT Piece1100 5 a8 Straiaht Connector 80 mm dia. EMT Piece1100 5 a9 Straiqht Connector 90 mm dia. EMT Piece1100 5 al0 Straiaht Connector 100 mm dia. EMT Piece1100 6 al End Bell 15 mm dia. Hot Dipped Piece1100 6 a2 End Bell 20 mm dia Hot Diooed Piece1100 6 a3 End Bell 25 mm dia. Hot Dipped Piece1100 6 a4 End Bell 32 mm dia. Hot Dioped Piece1100 6 as End Bell 40 mm dia. Hot Diooed Piece1100 6 a6 End Bell 50 mm dia. Hot Dipped Piece1100 6 a7 End Bell 65 mm dia. Hot Diooed Piece1100 6 a8 End Bell 80 mm dia. Hot Diooed Piece1100 6 a9 End Bell 90 mm dia. Hot Diooed Piece

Hot Dipped1100 (6) alO End Bell 100 mm dia. Galvanized Piece

SteelHot Dipped

1100 (6) all End Bell Galvanized Piece125 mm dia. Steel

Hot Dipped1100 (6) a12 End Bell 150 mm dia. Galvanized Piece

Steel1100 6 bl End Bell 20 mm dia PVC uPVC Piece1100 6 b2 End Bell 25 mm dia. PVC uPVC Piece1100 6) b3 End Bell 32 mm dia. PVC uPVC Piece1100 (6 b4 End Bell 40 mm dia. PVC uPVC Piece1100 (6 b5 End Bell 50 mm dia. PVC uPVC Piece1100 (6 b6 End Bell 63 mm dia. PVC uPVC Piece1100 (6 b7 End Bell 75 mm dia. PVC uPVC Piece

Page 44 VOL III

Page 106: Standardized Pay Items of Works for Civil Works Construction for

1100 (6) b8 End Bell 90 mm dia. PVC/uPVC Piece1100 (6) b9 End Bell 100 mm dia. PVC/uPVC Piece1100 (6) blO End Bell 110 mm dia. PVC/uPVC Piece1100 (6) b11 End Bell 160 mm dia. PVC/uPVC Piece1100 (7) al Weatherhead Condulet 15 mm dia. Riqid Steel, Piece'

1100 (7) a2 Weatherhead Condulet 20 mm diaRigid Steel,

Piece IHot Dipped

1100 (7) a3 Weatherhead Condulet 25 mm diaRigid Steel,

PieceHot Dipped

1100 (7) a4 Weatherhead Condulet 32 mm diaRigid Steel,

PieceHot Dipped

1100 (7) a5 Weatherhead Condulet 40 mm diaRigid Steel,

PieceHot Dipped

1100 (7) a6 Weatherhead Condulet 50 mm diaRigid Steel,

PieceHot Dipped

1100 (7) a7 Weatherhead Condulet 65 mm diaRigid Steel,

PieceHot Dipped

1100 (7) a8 Weatherhead Condulet 80 mm diaRigid Steel,

Piece" Hot Dipped

1100 (7) a9 Weatherhead Condulet 90 mm diaRigid Steel,

PieceHot Dipped

1100 (7) alO Weatherhead Condulet 100 mm diaRigid Steel,

PieceHot Dipped

1100 (7) all Weatherhead Condulet 125 mm diaRigid Steel,

PieceHot Dipped

1100 (7) a12 Weatherhead Condulet 150 mm diaKlgld Steel,

PieceHot Dipped1100 8 al Conduit Clamp 15 mm dia Metal Piece1100 8 a2 Conduit Clamp 20 mm dia Metal Piece1100 8 a3 Conduit Clarno 25 mm dia Metal Piece1100 8 a4 Conduit Clarno 32 mm dia Metal Piece1100 8) a5 Conduit Clamp 40 mm dia Metal Piece1100 8 a6 Conduit Clamp 50 mm dia Metal Piece1100 8 a7 Conduit Clarno 65 mm dia Metal Piece1100 8 a8 Conduit Clarno 80 mm dia Metal Piece1100 8 a9 Conduit Clamp 90 mm dia Metal Piece1100 '8 ala Conduit Clamp 100 mm dia Metal Piece1100 8 all Conduit Clamp 125 mm dia Metal Piece1100 8 bl Conduit Clarno 15 mm dia PVC Piece1100 8 b2 Conduit Clamp 20 mm dia PVC Piece1100 8 b3 Conduit Clamp 25 mm dia PVC Piece1100 8 b4 Conduit Clarno 32 mm dia PVC Piece1100 (8) b5 Conduit Clamp 40 mm dia PVC Piece

Page 45 VOLUME III

Page 107: Standardized Pay Items of Works for Civil Works Construction for

1100 8 b6 Conduit C1amo 50 mm dia PVC Piece1100 8 b7 Conduit Clamo 65 mm dia PVC Piece1100 8 b8 Conduit Clamo 80 mm dia PVC Piece1100 8 b9 Conduit Clamo 90 mm dia PVC Piece1100 8 bl0 Conduit Clamo 100 mm dia PVC Piece \1100/8 b11 Conduit Clamo 125 mm dia PVC Piece1100 (8) b12 Conduit Clamo 150 mm dia PVC Piece I1100(9) al G.!. Wire GA # 14 Kilo1100(9) a2 G.!. Wire GA #16 Kilo1100 9' Hacksaw Blade Piece

1100 ( 10 PVC Solvent Cement 400 cc Can1100 ( 11 al Octaqonal Junction Boxes Metal Piece1100 11) a2 Octaaonal Junction Boxes . PVC/uPVC Piece1100 lIT bl Utilitv Boxes Metal Piece1100 10 b2 Utilitv Boxes PVC/uPVC Piece1100 11) c1 Pull Box Metal Piece1100 11 c2 Pull Box PVCjuPVC Piece1100 11 dl Square Box Metal Piece1100 11 d2 Sauare Box PVC/uPVC Piece1100 12 Reinforced Concrete Pedestal Pole Lot1100 13 Red Lead Paint 1000 cc Can1100 14 a Groundinq Rod Coooer clad 16mm dia x 3m Lenqth1100 14 b Groundinq Rod Coooer clad 20mm dia x 3m Lenqth1100 14 c Groundina Rod Coooer clad 25mm dia x 3m Lenqth1100 15 Aoitonq or Aooroved Eaual Creosoted Wood Pole Piece1100 16 Anchor Rod Piece1100 17 Anchor Loq Piece1100 18 Powerload Studs with Nuts Piece1100 19 Conduits. Boxes & Fittinas Lumo Sum

1101 (1) al Electric Wire

1101 (1) a2 Electric Wire Roll

1101 (1) a3 Electric Wire2.6 mm dia. Roll

2

1101 (1) a4 Electric Wire Roll

1101 (1) a5 Electric Wire Roll

Page 46 VOLUME III

Page 108: Standardized Pay Items of Works for Civil Works Construction for

3.5mm2 Roll1101 (1) a6 Electric Wire

lW ffHHNlLHWN2

5.5mm2 Roll1101 (1) a7 Electric Wire

lWffHHN/THWN2

8.0mm2 Roll1101 (1) a8 Electric Wire

lW /THHN/THWN2

14mm2 Roll1101 (1) a9 Electric Wire

lWffHHN/THWN2

22mm2 Roll1101 (1) a10 Electric Wire lWffHHN/THWN2

Roll30mm2

1101 (1) all Electric WirelW/THHN/THWN2

38mm2 Roll1101 (1) a12 Electric Wire

lWffHHN/THWN2

50mm2 Roll1101 (1) a13 Electric Wire

lW/THHN/THWN2

60mm2 Roll1101 (1) a14 Electric Wire

lW ffHHNffHWN2

80mm2 Roll1101 (1) a15 Electric Wire

lW ffHHN/THWN2

100mm2 Roll1101 (1) a16 Electric Wire

lWffHHNffHWN2

125mm2 Roll1101 (1) a17 Electric Wire

lW/THHN/THWN2

150mm2 Roll1101 (1) a18 Electric Wire

lW/THHNffHWN2

200mm2 Roll1101 (1) a19 Electric Wire

lW/THHN/THWN2

250mm2 Roll1101 (1) a20 Electric Wire lW /THHNffHWN2

Roll325mm21101 (1) a21 Electric Wire

lW/THHNffHWN2

400mm2 Roll1101 (1) a22 Electric Wire

lW /THHNffHWN2

500mm2 Roll1101 (1) a23 Electric Wire

lW/THHN/THWN2Meter1.6 mm dia.

1101 (1) b1 Electric WirelWffHHN/THWN2

Page 47 VOL III

Page 109: Standardized Pay Items of Works for Civil Works Construction for

2.0 mm dia. Meter1101 (1) b2 Electric WireTWfTHHNfTHWN2

Meter2.6 mm dia.1101 (1) b3 Electric Wire

TWfTHHNfTHWN2

Meter3.2 mm dia.1101 (1) b4 Electric WireTWfTHHNfTHWN2

Meter2.0mm21101 (1) b5 Electric Wire

TWfTHHNfTHWN2

Meter3.5mm21101 (1) b6 Electric Wire

TWITHHNITHWN2

Meter5.5mm21101 (1) b7 Electric Wire

TWfTHHNfTHWN2

Meter8.0mm21101 (1) b8 Electric Wire

TWfTHHNfTHWN2

Meter14mm21101 (1) b9 Electric WireTWfTHHNfTHWN2

Meter22mm21101 (1) blO Electric Wire

TWfTHHNfTHWN2

Meter30mm2

1101 (1) b11 Electric WireTWfTHHNfTHWN2

Meter38mm21101 (1) b12 Electric Wire

TWITHHNITHWN2

Meter50mm21101 (1) b13 Electric Wire

TWfTHHNfTHWN2

Meter60mm21101 (1) b14 Electric Wire

TWITHHNfTHWN2

Meter80mm21101 (1) b15 Electric Wire

TWfTHHNfTHWN2

Meter100mm21101 (1) b16 Electric Wire

TWITHHNITHWN2

Meter125mm21101 (1) b17 Electric Wire

TWITHHNfTHWN2

Meter150mm21101 (1) b18 Electric Wire

TWfTHHNfTHWN2

Meter200mm21101 (1) b19 Electric Wire

TWITHHNITHWN2

Meter250mm21101 (1) b20 Electric WireTWITHHNITHWN2

Page 48 VOL II!

Page 110: Standardized Pay Items of Works for Civil Works Construction for

1101 (1) b21 Electric Wire325mm2 Meter

TW fTHHNrrHWN2

1101 (1) b22 Electric Wire400mm2 Meter

TW fTHHNrrHWN2

1101 (1) b23 Electric Wire500mm2 Meter

TWfTHHNrrHWN2

1101 2 al Electric Wire lCX4 XLPE Roll1101 2 a2 Electric Wire lCX6 XLPE Roll1101 2 a3 Electric Wire lC X 10 XLPE Roll1101 2 a4 Electric Wire lC X 25 XLPE Roll1101 2 as Electric Wire lC X 35 XLPE Roll1101 2 a6 Electric Wire lC X 50 XLPE Roll1101 2 a7 Electric Wire lC X 70 XLPE Roll1101 2 a8 Electric Wire lC X 95 XLPE Roll1101 2 a9 Electric Wire lC X 120 XLPE Roll1101 2 al0 Electric Wire lC X 185 XLPE Roll1101 2 all Electric Wire lC X 240 XLPE Roll1101 2 a12 Electric Wire lC X 300 XLPE Roll1101 2 a13 Electric Wire lC X 400 XLPE Roll1101 2 a14 Electric Wire lC X 500 XLPE Roll1101 2 bl Electric Wire 2CX4 XLPE Roll1101 2 b2 Electric Wire 2CX6 XLPE Roll1101 2 b3 Electric Wire 2C X 10 XLPE Roll1101 2 b4 Electric Wire 2C X 25 XLPE Roll1101 2 b5 Electric Wire 2C X 35 XLPE Roll1101 2 b6 Electric Wire 2C X 50 XLPE Roll1101 2 b7 Electric Wire 2C X 70 XLPE Roll1101 2 b8 Electric Wire 2C X 95 XLPE Roll1101 2 b9 Electric Wire 2C X 120 XLPE Roll1101 2 blO Electric Wire 2C X 185 XLPE Roll1101 2 bll Electric Wire 2C X 240 XLPE Roll1101 2 b12 Electric Wire 2C X 300 XLPE Roll1101 2 b13 Electric Wire 2C X 400 XLPE Roll1101 2 b14 Electric Wire 2C X 500 XLPE Roll1101 2 cl Electric Wire 3CX4 XLPE Roll1101 2 c2 Electric Wire 3CX 6 XLPE Roll1101 2 c3 Electric Wire 3C X 10 XLPE Roll1101 2 c4 Electric Wire 3C X 25 XLPE Roll1101 2 c5 Electric Wire 3C X 35 XLPE Roll1101 2 c6 Electric Wire 3C X 50 XLPE Roll1101 2) c7 Electric Wire 3C X 70 XLPE Roll1101 2) c8 Electric Wire 3C X 95 XLPE Roll

Page 49 VOL III

Page 111: Standardized Pay Items of Works for Civil Works Construction for

1101 2 c9 Electric Wire 3C X 120 XLPE Roll1101 2 cl0 Electric Wire 3C X 185 XLPE Roll1101 2 cll Electric Wire 3C X 240 XLPE Roll1101 2 c12 Electric Wire 3C X 300 XLPE Roll1101 2 c13 Electric Wire 3C X 400 XLPE Roll1101 2 c14 Electric Wire 3C X 500 XLPE Roll1101 3 al Electric Wire lCX4 XLPE Meter1101 3 a2 Electric Wire lCX6 XLPE Meter1101 3 a3 Electric Wire lC X 10 XLPE Meter1101 3 a4 Electric Wire lC X 25 XLPE Meter1101 3 as Electric Wire lC X 35 XLPE Meter1101 3 a6 Electric Wire lC X 50 XLPE Meter1101 3 a7 Electric Wire lC X 70 XLPE Meter1101 3 a8 Electric Wire lC X 95 XLPE Meter1101 3 a9 Electric Wire lC X 120 XLPE Meter1101 3 al0 Electric Wire lC X 185 XLPE Meter1101 3 all Electric Wire lC X 240 XLPE Meter1101 3 a12 Electric Wire lC X 300 XLPE Meter1101 3 a13 Electric Wire lC X 400 XLPE Meter1101 3 a14 Electric Wire lC X 500 XLPE Meter1101 3 bl Electric Wire 2CX4 XLPE Meter1101 3 b2 Electric Wire 2CX6 XLPE Meter1101 3 b3 Electric Wire 2C X 10 XLPE Meter1101 3 b4 Electric Wire 2C X 25 XLPE Meter1101 3 b5 Electric Wire 2C X 35 XLPE Meter1101 3 b6 Electric Wire 2C X 50 XLPE Meter1101 3 b7 Electric Wire 2C X 70 XLPE Meter1101 3 b8 Electric Wire 2C X 95 XLPE Meter1101(3 b9 Electric Wire 2C X 120 XLPE Meter1101 3) blO Electric Wire 2C X 185 XLPE Meter1101 3 bll Electric Wire 2C X 240 XLPE Meter1101 3 b12 Electric Wire 2C X 300 XLPE Meter1101 3 b13 Electric Wire 2C X 400 XLPE Meter1101 3 b14 Electric Wire 2C X 500 XLPE Meter1101 3 c1 Electric Wire 3CX4 XLPE Meter1101 3 c2 Electric Wire 3CX6 XLPE Meter1101 3 c3 Electric Wire 3C X 10 XLPE Meter .

1101 3 c4 Electric Wire 3C X 25 XLPE Meter1101 3 c5 Electric Wire 3C X 35 XLPE Meter1101 3 c6 Electric Wire 3C X 50 XLPE Meter1101 3 c7 Electric Wire 3C X 70 XLPE Meter1101 3 c8 Electric Wire 3C X 95 XLPE Meter1101 31 c9 Electric Wire 3C X 120 XLPE Meter

Page so VOL III

Page 112: Standardized Pay Items of Works for Civil Works Construction for

1101 (3 cl0 Electric Wire 3C X 185 XLPE Meter1101(3 c11 Electric Wire 3C X 240 XLPE Meter1101 (3 c12 Electric Wire 3C X 300 XLPE Meter1101 3 c13 Electric Wire 3C X 400 XLPE Meter1101 3 c14 Electric Wire 3C X 500 XLPE Meter1101 4 ACSR Wire/Cable Roll1101 5 ACSR Wire/Cable Meter1101 6 al Bare Coooer Wire 2.0 mm2 Meter1101 6 a2 Bare Coooer Wire 3.5 mm2 Meter1101 6 a3 Bare Coooer Wire 5.5 mm2 Meter1101 6 a4 Bare Coooer Wire 8.0 mm2 Meter1101 6 as Bare Coooer Wire 14 mm2 Meter1101 6 a6 Bare Coooer Wire 22 mm2 Meter1101 6 a7 Bare Coooer Wire 30 mm2 Meter1101 (6) a8 Bare Copper Wire 38 mm2 Meter1101 6 a9 Bare Coooer Wire 50 mm2 Meter1101 6) al0 Bare Coooer Wire 60 mm2 Meter1101 6) all Bare Copper Wire 80 mm2 Meter1101 6) a12 Bare Coooer Wire 100 mm2 Meter1101 6) a13 Bare Coooer Wire 125 mmL Meter1101 6) a14 Bare Coooer Wire 200 mmL Meter1101 6) a15 Bare Coooer Wire 250 mmL Meter1101 (6) a16 Bare Copper Wire 400 mmL Meter1101 7 al Sinale Pole Wall Switch on one switch olate Set1101 7 a2 Duolex (2 Sinale Pole Wall Switches on one switch olate) Set1101 7 a3 Triplex (3 Sinale Pole Wall Switches on one switch olate) Set1101 7 a4 Three-way Switch Set110f7j) as Four-way Switch Set1101 (7) a6 Double Pole Switch Set1101 (7) a7 Three Pole Switch Set1101 (7) a8 Dimmer Switch Set1101 (]) a9 Master Selector Switch Set1101 (7) al0 Automatic Door Switch Set1101 7 all Switch Bank Set1101 7 a12 Passive Infra-Red (Presence) Detector/Switch Surface Mounted Set1101 7 a13 Passive Infra-Red (Presence) Detector/Switch Recessed Set1101(8) al Sinale Convenience Outlet/Receotacle. Groundina Tvoe (GT) Set1101 (81 a2 Duolex Convenience Outlets/Receotacles (GT) Set1101 (8) a3 Heavy Duty Convenience Outlet/Receptacles (GT) Set1101 (8) a4 Weatheroroof Sinale Convenience Outlet/Receotacle (GT) Set1101 (8) as Weatheroroof Duplex Convenience Outlet/Receptacle (GT) Set1101 (8) a6 Soecial Puroose Outlet/Receotacle, (GT) for ACU, WH etc. Set

Page 51 VOLUME III

Page 113: Standardized Pay Items of Works for Civil Works Construction for

1101 (8) a7 Pop-uP tvpe/Floor Sinqle Convenience Outlet/Receptacle (GT) Set

1101 8 a8 Pop-uP tvpe/Floor Duplex Convenience Outlet/Receptacle (GT) Set

1101 8 a9 Poo-up tvoe/Floor Triplex Convenience Outlet/Receptacle (GT) Set

1101 (R alO Exolosion Proof tvoe Sinale Convenience Outlet/Receotacle (GT) Set

1101 (8) all Explosion Proof type Duplex Convenience Outlet/Receptacle (GT) Set

1101 8) a12 Sinale Convenience Outlet with Ground Fault Circuit'Interrupter Set

1101 8) a13 Duplex Convenience Outlet with GFCI Set I

1101 (9) a1 Grounding Clamps for Electric Wires 8.0 mm2 Piece

1101 9) a2 Groundinq Clamps for Electric Wires 14 mm2 Piece

1101 (9) a3 Grounding Clamps for Electric Wires 22 mm2 Piece

1101 (9) a4 Grounding Clamps for Electric Wires 30 mm2 Piece

1101 9 a5 Groundina Clamos for Electric Wires 38 mm2 Piece

1101 9 a6 Groundina Clamps for Electric Wires 50 mm2 Piece

1101 9 a7 Groundina Clamps for Electric Wires 60 mm2 Piece

1101 9 a8 Groundina Clamps for Electric Wires 80 mm2 Piece

1101 9 a9 Groundina Clamps for Electric Wires 100 mm2 Piece

1101 9 a10 Groundina Clamps for Electric Wires 125 mmL Piece

1101 9 all Groundina Clamos for Electric Wires 200 mmL Piece

1101 (9) a12 Grounding Clamps for Electric Wires 250 mm2 Piece

1101 (9) a13 Grounding Clamps for Electric Wires 400 mmL Piece

1101 10) PVCTaoe 19 mm dia x 18 mm Roll

1101 11 Rubber Tape/ Friction Taoe 19 mm dia x 227 q Roll

1101 12 a1 Mica Tubinq 6.35mm 1/4") Meter

1101 12 a2 Mica Tubinq 12.7mm 1/2") Meter

1101 12 a3 Mica Tubinq 19.0mm 3/4") Meter

1101 (12 a4 Mica Tubinq 25.40mm (1") Meter

1101 (13 Messenaer Wire Meter

1101 (14 Guv Wire Meter

1101 (15) Vibratina Bell Set1101 (16) Push button Set1101 (17) Buzzer Set

1101 (18) Wires and Wiring Devices Lump Sum

ITE~.1102 - ..POWERLOADCENTERt ..SWITCHGEAR AND...PANELBOARDS

VOLUME III

Set

Flushed Type

Surface Type

NEMA 1NEMA 1NEMA 1

NEMA 3R orNEMA 4X

NEMA 3R or

Plug-in Type

Plug-in Type

Page 52

a5 Panelboard with Main & Branch Breakers

Panelboard with Main & Branch BreakersPanelboard with Main & Branch BreakersPanelboard with Main & Branch Breakers

a4 Panelboard with Main & Branch Breakers

110211021102 1

1102 (1)

1102 (1)

Page 114: Standardized Pay Items of Works for Civil Works Construction for

1102 (1) a6 Panelboard with Main & Branch Breakers Plug-in TypeNEMA 3R or Free-Standing Set

NEMA 4X1102 (1) b1 Panelboard with Main & Branch Breakers Bolt-on Type NEMA 1 Flushed Tvoe Set

1102 (1) as Panelboard with Main & Branch Breakers Bolt-on Tyoe NEMA 1 Surface Tvoe Set1102 (1) a9 Panelboard with Main & Branch Breakers Bolt-on Type NEMA 1 Free-Standina Set

1102 (1) a10 Panelboard with Main & Branch Breakers Bolt-on TypeNEMA 3R or Flushed Type Set

NEMA 4X I

1102 (1) all Panelboard with Main & Branch Breakers Bolt-on TypeNEMA 3R or

Surface Type SetNEMA 4X

1102 (1) a12 Panelboard with Main & Branch Breakers Bolt-on TypeNEMA 3R or Free-Standing Set

NEMA 4X1102 (2) a1 Panelboard with Main Luas & Branch Breakers Plua-in Type NEMA 1 Flushed Tvoe Set

1102 2 a2 Panelboard with Main Luas & Branch Breakers Plua-in Type NEMA 1 Surface Tvoe Set1102 (2) a3 Panelboard with Main Luas & Branch Breakers Plua-in Type NEMA 1 Free-Standina Set

1102 (2) a4 Panelboard with Main Lugs & Branch Breakers Plug-in TypeNEMA 3R or

Flushed Type SetNEMA 4X

1102 (2) as Panelboard with Main Lugs & Branch Breakers Plug-in TypeNEMA 3R or

Surface Type SetNEMA 4X

1102 (2) a6 Panelboard with Main Lugs & Branch Breakers Plug-in TypeNEMA 3R or Free-Standing Set

NEMA 4X1102 2) b1 Panelboard with Main Luas & Branch Breakers Bolt-on Tvoe NEMA 1 Flushed Tvee Set

1102 2) b2 Panelboard with Main Luas & Branch Breakers Bolt-on Type NEMA 1 Surface Tvoe Set

1102 2) b3 Panelboard with Main Luas & Branch Breakers Bolt-on Type NEMA 1 Free-Standina Set

1102 (2) b4 Panelboard with Main Lugs & Branch Breakers Bolt-on TypeNEMA 3R or

Flushed Type SetNEMA 4X

1102 (2) bS Panelboard with Main Lugs & Branch Breakers Bolt-on TypeNEMA 3R or

Surface Type SetNEMA 4X

1102 (2) b6 Panelboard with Main Lugs & Branch Breakers Bolt-on TypeNEMA 3R or Free-Standing Set

NEMA 4X1102 3 a1 Safety Switch. Fusible Tvoe NEMA 1 Surface Tvoe Set

1102 3 a2 Safe v Switch Fusible Tvoe NEMA 3R or Surface Tvoe Set

1102 3 bl Safe v Switch. Non-Fusible Tvoe NEMA 1 Surface Tvee Set

1102 3 b2 Safe v Switch. Non-Fusible Tvoe NEMA 3R or Surface Tvee Set

1102 3 c1 Fuse Cut-out Box NEMA 1 Flushed Tvoe Set

1102 3 c2 Fuse Cut-out Box NEMA 1 Surface Tvoe Set

1102 (3) c3 Fuse Cut-out BoxNEMA 3R or Flushed Type Set

NEMA 4X

1102 (3) c4 Fuse Cut-out BoxNEMA 3R or

Surface Type SetNEMA 4X

1102 4) al Main Enclosed Automatic Circuit Breaker NEMA 1 Flushed Tvee Set

1102 4) a2 Main Enclosed Automatic Circuit Breaker NEMA 1 Surface Tvoe Set

1102 4) a3 Main Enclosed Automatic Circuit Breaker NEMA 1 Free-Standina Set

Page 53 VOL III

Page 115: Standardized Pay Items of Works for Civil Works Construction for

1102 (4) a4 Main Enclosed Automatic Circuit Breaker NEMA 3R orFlushed Type Set

NEMA 4X

1102 (4) a5 Main Enclosed Automatic Circuit Breaker NEMA 3R orSurface Type Set

NEMA 4XNEMA 3R or

,1102 (4) a6 Main Enclosed Automatic Circuit Breaker

NEMA 4XFree-Standing Set

1102 (4) bl Enclosed Automatic Circuit Breaker NEMA 1 Flushed Type i Set I

1102 (4) b2 Enclosed Automatic Circuit Breaker NEMA 1 Surface Type I Set

1102 (4) b3 Enclosed Automatic Circuit Breaker NEMA 3R orFlushed Type Set

NEMA 4X

1102 (4) b4 Enclosed Automatic Circuit Breaker NEMA 3R orSurface Type Set

NEMA 4X

1102 (5) alMotor Control Center with Main, Branch Breakers and Motor

NEMA 1 Flushed Type SetStarters/controllers

1102 (5) a2Motor Control Center with Main, Branch Breakers and Motor

NEMA 1 Surface Type SetStarters/controllers

1102 (5) a3 Motor Control Center with Main, Branch Breakers and MotorNEMA 1 Free-Standing SetStarters/controllers

1102 (5) a4 Motor Control Center with Main, Branch Breakers and Motor NEMA 3R orFlushed Type SetStarters/controllers NEMA 4X

1102 (5) a5Motor Control Center with Main, Branch Breakers and Motor NEMA 3R or

Surface Type SetStarters/controllers NEMA 4X

1102 (5) a6 Motor Control Center with Main, Branch Breakers and Motor NEMA 3R orFree-Standing SetStarters/controllers NEMA 4X

1102 6 Cupper Bus Bar NEMA I Enclosure Surface Mounted Set1102 7 al Pad Mounted Transformer (OISC) Free Standinq Set1102 7 a2 Pole Mounted Transformer (OISC) Pole tvpe Set1102 7 b Drv Tvoe Transformer Set1102 8 al Generator Stand-by Set1102 8 a2 Generator Continuous Set1102 8 b1 Hiqh Voltaae Switch Gear without meterina facilities Free Standina Set1102 8 b2 Low Voltaae Switch Gear without meterina facilities Free Standina Set1102 8 c Svnchronizinq Panel for Generator Free Standina Set1102 9 ACSR Meter

1102 10 Transformer bracket Set1102 11 Power fuse assemblY Set1102 12 Liqhtnina Arrester with fuse cut-off Set1102 (13 Creosoted pole Piece1102 14 Concrete pole Piece1102 15 Pin tvpe insulator Piece1102 16 Pole top pin Piece

Page 54 VOL III

Page 116: Standardized Pay Items of Works for Civil Works Construction for

1102 17 Machine bolt Piece1102 19 Washer Piece1102 20 Kilowatt Meter with base Set

rrEML11():t;S;J~I(;HT1N.G:~IXTUR.E •••.•••« ••..• ........ . <.

iIm"'_1I. Jt ......1103 (1) Liahtina Fixtures Lumo Sum1103 (2) a1 Fluorescent Liahtina Fixture w HPF-NCPF Ballast 1 - 18 20watts Box Type Surface Mounted Set1103 2 a2 Fluorescent Liahtina Fixture w HPF-NCPF Ballast 2 - 18 20watts Box Type Surface Mounted Set1103 2 a3 Fluorescent Liahtina Fixture w HPF-NCPF Ballast 3 - 18 20watts Box Type Surface Mounted Set1103 2 a4 Fluorescent Liqhtina Fixture w HPF-NCPF Ballast 4 - 18 20watts Box Type Surface Mounted Set1103 2 as Fluorescent Liqhtinq Fixture w HPF-NCPF Ballast 1 - 18 20watts Box Type Recessed Coved Set1103 2 a6 Fluorescent Liahtina Fixture w HPF-NCPF Ballast 2 - 18 20watts Box Type Recessed Coved Set1103 2 a7 Fluorescent Liqhtinq Fixture w HPF-NCPF Ballast 3 - 18 20watts Box Type Recessed Coved Set1103 2 a8 Fluorescent Liahtina Fixture w HPF-NCPF Ballast 4 - 18 20watts Box Type Recessed Coved Set1103 2) a9 Fluorescent Liahtinq Fixture w Electronic Ballast 1 - 18 20watts Box Type Surface Mounted Set1103 2) a10 Fluorescent Liahtina Fixture w Electronic Ballast 2 - 18 20watts Box Type Surface Mounted Set1103 2 all Fluorescent Liahtina Fixture w Electronic Ballast 3 - 18 20watts Box Type Surface Mounted Set1103 2 a12 Fluorescent Liahtina Fixture w Electronic Ballast 4 - 18 20watts Box Type Surface Mounted Set1103 2 a13 Fluorescent Liqhtina Fixture w Electronic Ballast 1 - 18 20watts Box Type Recessed Coved Set1103 2 a14 Fluorescent Liahtina Fixture w Electronic Ballast 2 - 18 20watts Box Tyoe Recessed Coved Set1103 2 a1S Fluorescent Liahtina Fixture w Electronic Ballast 3 - 18 20watts Box Tyoe Recessed Coved Set1103 2 a16 Fluorescent Liahtina Fixture w Electronic Ballast 4 - 18/20watts Box Type Recessed Coved Set1103 2 a17 Fluorescent Liahtina Fixture w HPF-NCPF Ballast 1 - 26watts Box Tyoe Surface Mounted Set1103 2 a18 Fluorescent Liahtina Fixture w HPF-NCPF Ballast 2 - 26watts Box Type Surface Mounted Set1103 2 a19 Fluorescent Liqhtinq Fixture w HPF-NCPF Ballast 3 - 26watts Box Type Surface Mounted Set1103 2 a20 Fluorescent Liahtina Fixture w HPF-NCPF Ballast 4 - 26watts Box Tyoe Surface Mounted Set1103 2 a21 Fluorescent Liahtina Fixture w HPF-NCPF Ballast 1 - 26watts Box Type Recessed/Coved Set1103 2 a22 Fluorescent Liahtina Fixture w HPF-NCPF Ballast 2 - 26watts Box Type Recessed Coved Set1103 (2) a23 Fluorescent Liqhtina Fixture w HPF-NCPF Ballast 3 - 26watts Box Tyoe Recessed Caved . Set1103 (2) a24 Fluorescent Liahtina Fixture w HPF-NCPF Ballast 4 - 26watts Box Tyoe Recessed Caved Set1103 2 a2S Fluorescent Liahtinq Fixture w Electronic Ballast 1 - 26watts Box Tyoe Surface Mounted Set1103 2 a26 Fluorescent Liahtina Fixture w Electronic Ballast 2 - 26watts Box Tyoe Surface Mounted Set1103 2 a27 Fluorescent Liahtina Fixture w Electronic Ballast 3 - 26watts Box Tyoe Surface Mounted Set1103 2 a28 Fluorescent Liahtina Fixture w Electronic Ballast 4 - 26watts Box Type Surface Mounted Set1103 2 a29 Fluorescent Liahtina Fixture w Electronic Ballast 1 - 26watts Box Type Recessed Coved Set1103 2 a30 Fluorescent Liahtina Fixture w Electronic Ballast 2 - 26watts Box Type Recessed Coved Set1103 2 a31 Fluorescent Liqhtinq Fixture w Electronic Ballast 3 - 26watts Box Type Recessed Coved Set1103 2 a32 Fluorescent Liahtina Fixture w Electronic Ballast 4 - 26watts Box Type Recessed Coved Set1103 2 a33 Fluorescent Liqhtina Fixture w HPF-NCPF Ballast 1 - 36 38 40watts Box Type Surface Mounted Set1103 2) a34 Fluorescent Liahtina Fixture w HPF-NCPF Ballast 2 - 36 38 40watts Box Tyoe Surface Mounted Set1103 2) a3S Fluorescent Liahtina Fixture w HPF-NCPF Ballast 3 - 36 38 40watts Box Type Surface Mounted Set

Page 55 VOL III

Page 117: Standardized Pay Items of Works for Civil Works Construction for

1103 2 a36 Fluorescent Liahtina Fixture w HPF-NCPFBallast 4 - 36/38 40watts Box Tvoe Surface Mounted Set1103 2 a37 Fluorescent Liahtina Fixture w HPF-NCPFBallast 1 - 36 38 40watts Box Tvee Recessed Coved Set1103 2 a38 Fluorescent Liahtina Fixture w HPF-NCPFBallast 2 - 36 38 40watts Box Tvoe Recessed Coved Set1103 2 a39 Fluorescent Liahtina Fixture w HPF-NCPFBallast 3 - 36/38 40watts Box Tvee Recessed Coved Set1103 2 a40 Fluorescent Liahtina Fixture w HPF-NCPFBallast 4 - 36 38 40watts Box Tvee Recessed Coved Set \1103 2 a41 Fluorescent Liahtina Fixture w Electronic Ballast 1 - 36 38 40watts Box Tvoe Surface Mounted Set1103 2 a42 Fluorescent Liahtina Fixture w Electronic Ballast 2 - 36 38 40watts Box Tvee Surface Mounted Set I

1103 2 a43 Fluorescent Liahtina Fixture w Electronic Ballast 3 - 36 38 40watts Box Tvee Surface Mounted Set1103 2 a44 Fluorescent Liahtina Fixture w Electronic Ballast 4 - 36 38 40watts Box Tvoe Surface Mounted Set1103 2 a45 Fluorescent Liahtina Fixture w Electronic Ballast 1 - 36 38 40watts Box Tvee Recessed Coved Set1103 2 a46 Fluorescent Liahtina Fixture w Electronic Ballast 2 - 36 38 40watts Box Tvee Recessed Coved Set1103 i) a47 Fluorescent Liahtina Fixture w Electronic Ballast 3 - 36/38 40watts Box Tvoe Recessed Coved Set1103 2) a48 Fluorescent Liahtina Fixture w Electronic Ballast 4 - 36 38/40watts Box Tvee Recessed/Coved Set

Acrylic /

1103 (2) bl Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 18/20watts Prismatic / Surface Mounted SetPolycarbonateDiffllc;prAcrylic /

1103 (2) b2 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 18/20watts Prismatic / Surface Mounted SetPolycarbonate1""\;4'f •• ~~~

Acrylic /

1103 (2) b3 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 18/20watts Prismatic / Surface Mounted SetPolycarbonateDifflJc;prAcrylic /

1103 (2) b4 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 18/20watts Prismatic / Surface Mounted SetPolycarbonateDiffllc;prAcrylic

1103 (2) b5 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 18/20watts Prismatic Recessed SetDiffuserAcrylic

1103 (2) b6 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 18/20watts Prismatic Recessed SetDiffuserAcrylic

1103 (2) b7 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 18/20watts Prismatic Recessed SetDiffuserAcrylic

1103 (2) b8 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 18/20watts Prismatic Recessed SetDiffuser

Page 56 VOL III

Page 118: Standardized Pay Items of Works for Civil Works Construction for

Acrylic /

1103 (2) b9 Fluorescent Lighting Fixture w/Electronic Ballast 1 - 18/20watts Prismatic / Surface Mounted SetPolycarbonaterliffllCO:>I"Acrylic /

1103 (2) blO Fluorescent Lighting Fixture w/Electronic Ballast 2 - 18/20watts Prismatic / Surface Mounted SetPolycarbonaterliffllcO:>I"Acrylic /

1103 (2) b11 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 18/20watts Prismatic / Surface Mounted SetPolycarbonaterliffllcO:>I"Acrylic /

1103 (2) b12 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 18/20watts Prismatic / Surface Mounted SetPolycarbonateniffllcO:>I"Acrylic

1103 (2) b13 Fluorescent Lighting Fixture w/Electronic Ballast 1 - 18/20watts Prismatic Recessed SetDiffuserAcrylic

1103 (2) b14 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 18/20watts Prismatic Recessed SetDiffuserAcrylic

1103 (2) b15 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 18/20watts Prismatic Recessed SetDiffuserAcrylic

1103 (2) b16 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 18/20watts Prismatic Recessed SetDiffuserAcrylic /

1103 (2) b17 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 26watts Prismatic / Surface Mounted SetPolycarbonate

Acrylic /

1103 (2) b18 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 26watts Prismatic / Surface Mounted SetPolycarbonate

Acrylic /

1103 (2) b19 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 26watts Prismatic / Surface Mounted SetPolycarbonate

Page 57 VOL III

Page 119: Standardized Pay Items of Works for Civil Works Construction for

,~.----- Acrylic j

1103 (2) b20 Fluorescent Lighting Fixture wjHPF-NCPF Ballast 4 - 26watts Prismatic j Surface Mounted SetPolycarbonate

Acrylic1103 (2) b21 Fluorescent Lighting Fixture wjHPF-NCPF Ballast 1 - 26watts Prismatic Recessed Set

DiffuserAcrylic

1103 (2) b22 Fluorescent Lighting Fixture wjHPF-NCPF Ballast 2 - 26watts Prismatic Recessed SetDiffuserAcrylic

1103 (2) b23 Fluorescent Lighting Fixture wjHPF-NCPF Ballast 3 - 26watts Prismatic Recessed SetDiffuserAcrylic

1103 (2) b24 Fluorescent Lighting Fixture wjHPF-NCPF Ballast 4 - 26watts Prismatic Recessed SetDiffuserAcrylic j

1103 (2) b25 Fluorescent Lighting Fixture wjElectronic Ballast 1 - 26watts Prismatic j Surface Mounted SetPolycarbonate

Acrylic j

1103 (2) b26 Fluorescent Lighting Fixture wjElectronic Ballast 2 - 26watts Prismatic j Surface Mounted SetPolycarbonate

Acrylic j

1103 (2) b27 Fluorescent Lighting Fixture wjElectronic Ballast 3 - 26watts Prismatic j Surface Mounted SetPolycarbonate

Acrylic j .

1103 (2) b28 Fluorescent Lighting Fixture wjElectronic Ballast 4 - 26watts Prismatic j Surface Mounted SetPolycarbonate

Acrylic1103 (2) b29 Fluorescent Lighting Fixture wjElectronic Ballast 1 - 26watts Prismatic Recessed Set

DiffuserAcrylic

1103 (2) b30 Fluorescent Lighting Fixture wjElectronic Ballast 2 - 26watts Prismatic Recessed SetDiffuserAcrylic

1103 (2) b31 Fluorescent Lighting Fixture wjElectronic Ballast 3 - 26watts Prismatic Recessed SetDiffuser

Page 58 VOL III

Page 120: Standardized Pay Items of Works for Civil Works Construction for

Acrylic1103 (2) b32 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 26watts Prismatic Recessed Set

DiffuserAcrylic /

1103 (2) b33 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 36/38/40wattsPrismatic / Surface Mounted Set

PolycarbonateOifftlc;prAcrylic /

1103 (2) b34 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 36/38/40wattsPrismatic /

Surface Mounted SetPolycarbonate

Acrylic /

1103 (2) b35 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 36/38/40wattsPrismatic / Surface Mounted Set

Polycarbonate

Acrylic /

1103 (2) b36 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 36/38/40wattsPrismatic / Surface Mounted Set

Polycarbonate

Acrylic1103 (2) b37 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 36/38/40watts Prismatic Recessed Set

DiffuserAcrylic

1103 (2) b38 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 36/38/40watts Prismatic Recessed SetDiffuserAcrylic

1103 (2) b39 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 36/38/40watts Prismatic Recessed SetDiffuserAcrylic

1103 (2) b40 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 36/38/40watts Prismatic Recessed SetDiffuserAcrylic /

1103 (2) b41 Fluorescent Lighting Fixture w/Electronic Ballast 1 - 36/38/40wattsPrismatic / Surface Mounted Set

Polycarbonate...Acrylic /

1103 (2) b42 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 36/38/40wattsPrismatic / Surface Mounted Set

Polycarbonate

Acrylic /

1103 (2) b43 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 36/38/40wattsPrismatic / Surface Mounted Set

PolycarbonateDiffllc;pr

Page 59 VOL III

Page 121: Standardized Pay Items of Works for Civil Works Construction for

Acrylic /

1103 (2) b44 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 36/38/40watts Prismatic / Surface Mounted SetPolycarbonate

Acrylic1103 (2) b45 Fluorescent Lighting Fixture w/Electronic Ballast 1 - 36/38/40watts Prismatic Recessed Set

DiffuserAcrylic

1103 (2) b46 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 36/38/40watts Prismatic Recessed •• SetDiffuserAcrylic

1103 (2) b47 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 36/38/40watts Prismatic Recessed SetDiffuserAcrylic

1103 (2) b48 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 36/38/40watts Prismatic Recessed SetDiffuser

Mirrorized

1103 (2) c1 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 18/20watts Aluminum 300 x 600mm Surface SetLouvre, MountedJTTerTvoe

Mirrorized

1103 (2) c2 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 18/20watts Aluminum 300 x 600mm Surface SetLouvre, Mounted

I raTTerTvoeMirrorized

1103 (2) c3 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 18/20wattsAluminum 600 x 600mm Surface Set

Louvre, MountedIrOTTPrTvneMirrorized

1103 (2) c4 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 18/20wattsAluminum 600 x 600mm Surface Set

Louvre, MountedI rOTTf>r TVDeMirrorized

1103 (2) c5 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 18/20watts Aluminum 600 x 600mm Surface SetLouvre, Mounted-IrOTTPrIVDP

Mirrorized

1103 (2) c6 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 18/20wattsAluminum 300 x 600mm Recessed Set

Louvre,IrnTTPrIvoe

Page 60 VOL III

Page 122: Standardized Pay Items of Works for Civil Works Construction for

Mirrorized

1103 (2) c7 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 18/20wattsAluminum

300 x 600mm Recessed SetLouvre,

IrOTTer I VDeMirrorized

1103 (2) c8 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 18/20wattsAluminum

600 x 600mm Recessed SetLouvre,-I rnrn'r ,VnP

Mirrorized

1103 (2) c9 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 18/20wattsAluminum

600 x 600mm Recessed SetLouvre,

rnTTPr I vneMirrorized

1103 (2) c10 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 18/20wattsAluminum 600 x 600mm Recessed Set

Louvre,rofTer TvoeMirrorized

1103 (2) cll Fluorescent Lighting Fixture w/Electronic Ballast 1 - 18/20wattsAluminum 300 x 600mm Surface

SetLouvre, Mounted

Troffer TVDeMirrorized

1103 (2) c12 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 18/20wattsAluminum 300 x 600mm Surface

SetLouvre, Mounted

I rnTTPrTvnPMirrorized

1103 (2) c13 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 18/20wattsAluminum 600 x 600mm Surface

SetLouvre, MountednITPrTvnp

Mirrorized

1103 (2) c14 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 18/20wattsAluminum 600 x 600mm Surface

SetLouvre, Mounted

I roTTerTvoeMirrorized

1103 (2) c1S Fluorescent Lighting Fixture w/Electronic Ballast 4 - 18/20wattsAluminum 600 x 600mm Surface

SetLouvre, Mounted

I rOTTerTvnpMirrorized

1103 (2) c16 Fluorescent Lighting Fixture w/Electronic Ballast 1 - 18/20wattsAluminum

300 x 600mm Recessed SetLouvre,

IrnTTPrTvnp

Page 61 VOL III

Page 123: Standardized Pay Items of Works for Civil Works Construction for

Mirrorized

1103 (2) el7 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 18/20wattsAluminum

300 x 600mm Recessed SetLouvre,

I rnrtpr TvnpMirrorized

1103 (2) c18 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 18/20wattsAluminum

600 x 600mm Recessed SetLouvre,

I rnrtpr TvnpMirrorized

1103 (2) c19 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 18/20wattsAluminum

600 x 600mm Recessed SetLouvre,

I rnrtpr TvnpMirrorized

1103 (2) c20 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 18/20wattsAluminum

600 x 600mm Recessed SetLouvre,

I rnrtpr TvnpMirrorized

1103 (2) c21 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 26wattsAluminum 300 x 600mm Surface

SetLouvre, Mounted

Trnrtpr TvOF'Mirrorized

1103 (2) c22 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 26wattsAluminum 300 x 600mm Surface

SetLouvre, Mounted

I rnrtpr TvnpMirrorized

1103 (2) c23 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 26wattsAluminum 600 x 600mm Surface

SetLouvre, Mounted

I rnrtpr TvnpMirrorized

1103 (2) c24 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 26wattsAluminum 600 x 600mm Surface

SetLouvre, Mounted

I rnrtpr TvnpMirrorized

1103 (2) c25 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 26wattsAluminum 600 x 600mm Surface

SetLouvre, Mounted

Trnrtpr TvOF'Mirrorized

1103 (2) c26 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 26wattsAluminum

300 x 600mm Recessed SetLouvre,

I rnrtpr TvOF'

Page 62 VOL III

Page 124: Standardized Pay Items of Works for Civil Works Construction for

Mirrorized

1103 (2) c27 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 26wattsAluminum 300 x 600mm Recessed Set

Louvre,.. -I rnrn'r I vnpMirrorized

1103 (2) c28 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 26wattsAluminum 600 x 600mm Recessed Set

Louvre,I rntTPr IvnpMirrorized

1103 (2) c29 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 26wattsAluminum 600 x 600mm Recessed Set

Louvre,I rntTPr vneMirrorized

1103 (2) c30 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 26watts Aluminum 600 x 600mm Recessed SetLouvre,

I rntTer VDeMirrorized

1103 (2) c31 Fluorescent Lighting Fixture w/Electronic Ballast 1 - 26wattsAluminum 300 x 600mm Surface Set

Louvre, Mounted..rnrn'r IvnpMirrorized

1103 (2) c32 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 26wattsAluminum 300 x 600mm Surface Set

Louvre, Mounted-i rntTPr IvnpMirrorized

1103 (2) c33 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 26wattsAluminum 600 x 600mm Surface Set

Louvre, Mountedi rotTer TVDeMirrorized

1103 (2) c34 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 26wattsAluminum 600 x 600mm Surface Set

Louvre, Mounted•rotTer TVDeMirrorized

1103 (2) c35 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 26watts Aluminum 600 x 600mm Surface SetLouvre, MountedJtTer Tvne

Mirrorized

1103 (2) c36 Fluorescent Lighting Fixture w/Electronic Ballast 1 - 26watts Aluminum 300 x 600mm Recessed SetLouvre,

I rotTPr Tvne

Page 63 VOL III

Page 125: Standardized Pay Items of Works for Civil Works Construction for

Mirrorized

1103 (2) c37 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 26wattsAluminum

300 x 600mm Recessed SetLouvre,

Irnrrpr TvnpMirrorized

1103 (2) c38 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 26wattsAluminum

600 x 600mm Recessed SetLouvre,

Il"nIT':>1"Tv"",Mirrorized

1103 (2) c39 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 26wattsAluminum

600 x 600mm Recessed SetLouvre,

Irnrrpr Tv"",Mirrorized

1103 (2) c40 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 26wattsAluminum

600 x 600mm Recessed SetLouvre,

Il"nIT':>1"Tv"",Mirrorized

1103 (2) c41 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 36/38/40wattsAluminum 300 x 1200mm Surface

SetLouvre, Mounted

Tl"nrr':>l"Tvn,:>Mirrorized

1103 (2) c42 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 36/38/40wattsAluminum 300 x 1200mm Surface

SetLouvre, Mounted

Irnrrpr Tv"",Mirrorized

1103 (2) c43 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 36/38/40wattsAluminum 600 x 1200mm Surface

SetLouvre, Mounted

Irnrr,:>r Tvn,:>Mirrorized

1103 (2) c44 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 36/38/40wattsAluminum 600 x 1200mm Surface

SetLouvre, Mounted

Trnrr,:>r Tv"",Mirrorized

1103 (2) c45 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 36/38/40wattsAluminum 600 x 1200mm Surface

SetLouvre, Mounted

Irnrr,:>r Tvn,:>Mirrorized

1103 (2) c46 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 36/38/40wattsAluminum

300 x 1200mm Recessed SetLouvre,

Irnrrpr Tv"",

Page 64 VOL III

Page 126: Standardized Pay Items of Works for Civil Works Construction for

Mirrorized

1103 (2) c47 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 36/38/40wattsAluminum

300 x 1200mm Recessed SetLouvre,

I roTTer .VDeMirrorized

1103 (2) c48 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 36/38/40wattsAluminum

600 x 1200mm Recessed SetLouvre,~~

I rnrrpr vnpMirrorized

1103 (2) c49 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 36/38/40wattsAluminum

600 x 1200mm Recessed SetLouvre,

I rnrrer vneMirrorized

1103 (2) c50 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 36/38/40wattsAluminum

600 x 1200mm Recessed SetLouvre,

I rarrer .VDeMirrorized

1103 (2) c51 Fluorescent Lighting Fixture w/Electronic Ballast 1 - 36/38/40wattsAluminum 300 x 1200mm Surface

SetLouvre, Mounted

rarrer voeMirrorized

1103 (2) c52 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 36/38/40wattsAluminum 300 x 1200mm Surface

SetLouvre, Mounted

rnrrer voeMirrorized

1103 (2) c53 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 36/38/40wattsAluminum 600 x 1200mm Surface

SetLouvre, Mounted~~rnrrpr vne

Mirrorized

1103 (2) c54 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 36/38/40wattsAluminum 600 x 1200mm Surface

SetLouvre, Mounted

raTTer voeMirrorized

1103 (2) c55 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 36/38/40wattsAluminum 600 x 1200mm Surface

SetLouvre; Mounted-rnrrpr vne

Mirrorized

1103 (2) c56 Fluorescent Lighting Fixture w/Electronic Ballast 1 - 36/38/40wattsAluminum

300 x 1200mm Recessed SetLouvre,

~.raTTer Ivoe

Page 65 VOL III

Page 127: Standardized Pay Items of Works for Civil Works Construction for

Mirrorized

1103 (2) c57 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 36/38/40wattsAluminum

300 x 1200mm Recessed SetLouvre,

I rnft~r Tvn~Mirrorized

1103 (2) c58 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 36/38/40wattsAluminum

600 x 1200mm Recessed SetLouvre,

rrnft~r Tvn~Mirrorized

1103 (2) c59 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 36/38/40wattsAluminum

600 x 1200mm Recessed SetLouvre,

I rnft~r TvnpMirrorized

1103 (2) c60 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 36/38/40wattsAluminum

600 x 1200mm Recessed SetLouvre,

I rnrrpr TvnP

1103 (2) dl Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 18/20wattsIndustrial

Surface Mounted SetTVDe

1103 (2) d2 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 18/20wattsIndustrial

Surface Mounted SetTvne

1103 (2) d3 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 18/20wattsIndustrial

Surface Mounted SetTVDe

1103 (2) d4 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 18/20wattsIndustrial

Surface Mounted SetTVDe

1103 (2) d5 Fluorescent Lighting Fixture w/Electronic Ballast 1 - 18/20wattsIndustrial

Surface Mounted SetTVDe

1103 (2) d6 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 18/20wattsIndustrial

Surface Mounted SetTvne

1103 (2) d7 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 18/20wattsIndustrial

Surface Mounted SetTvnP

1103 (2) d8 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 18/20wattsIndustrial

Surface Mounted SetTVDe

1103 (2) d9 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 26wattsIndustrial

Surface Mounted SetTvne

1103 (2) dl0 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 26wattsIndustrial

Surface Mounted SetTVDe

1103 (2) dll Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 26wattsIndustrial

Surface Mounted SetTVDe

1103 (2) d12 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 26wattsIndustrial

Surface Mounted SetTVDe

1103 (2) dB Fluorescent Lighting Fixture w/Electronic Ballast 1 - 26wattsIndustrial

Surface Mounted SetTVDe

Page 66 VOL III

Page 128: Standardized Pay Items of Works for Civil Works Construction for

1103 (2) d14 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 26wattsIndustrial

Surface Mounted SetTVDe

1103 (2) d15 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 26wattsIndustrial

Surface Mounted SetTvne

1103 (2) d16 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 26wattsIndustrial

Surface Mounted SetTvne

1103 (2) d17 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 1 - 36/38/40wattsIndustrial

Surface Mounted SetTvoe

1103 (2) d18 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 2 - 36/38/40wattsIndustrial

Surface Mounted SetTVDe

1103 (2) d19 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 3 - 36/38/40wattsIndustrial

Surface Mounted SetTvoe

1103 (2) d20 Fluorescent Lighting Fixture w/HPF-NCPF Ballast 4 - 36/38/40wattsIndustrial

Surface Mounted SetTvne

1103 (2) d21 Fluorescent Lighting Fixture w/Electronic Ballast 1 - 36/38/40wattsIndustrial

Surface Mounted SetTVDe

1103 (2) d22 Fluorescent Lighting Fixture w/Electronic Ballast 2 - 36/38/40wattsIndustrial

Surface Mounted SetTVDe

1103 (2) d23 Fluorescent Lighting Fixture w/Electronic Ballast 3 - 36/38/40wattsIndustrial

Surface Mounted SetTvne

1103 (2) d24 Fluorescent Lighting Fixture w/Electronic Ballast 4 - 36/38/40wattsIndustrial

Surface Mounted SetTvnPLouvre /

1103 (3) a1 Compact Fluorescent Lighting Fixture 11watts Prismatic Surface Mounted SetDiffuserLouvre /

1103 (3) a2 Compact Fluorescent Lighting Fixture 13watts Prismatic Surface Mounted SetDiffuserLouvre /

1103 (3) a3 Compact Fluorescent Lighting Fixture 16watts Prismatic Surface Mounted SetDiffuserLouvre /

1103 (3) a4 Compact Fluorescent Lighting Fixture 18watts Prismatic Surface Mounted SetDiffuserLouvre /

1103 (3) as Compact Fluorescent Lighting Fixture 21watts Prismatic Surface Mounted SetDiffuserLouvre /

1103 (3) a6 Compact Fluorescent Lighting Fixture 28watts Prismatic Surface Mounted SetDiffuserLouvre /

1103 (3) a7 Compact Fluorescent Lighting Fixture 38watts Prismatic Surface Mounted SetDiffuser

Page 67 VOL III

Page 129: Standardized Pay Items of Works for Civil Works Construction for

Louvre j1103 (3) a8 Compact Fluorescent Lighting Fixture 11watts Prismatic Recessed Set

DiffuserLouvre j

1103 (3) a9 Compact Fluorescent Lighting Fixture 13watts Prismatic Recessed SetDiffuserLouvre j

1103 (3) alO Compact Fluorescent Lighting Fixture l6watts Prismatic Recessed SetDiffuserLouvre j

1103 (3) all Compact Fluorescent Lighting Fixture l8watts Prismatic Recessed SetDiffuserLouvre j

1103 (3) a12 Compact Fluorescent Lighting Fixture 2lwatts Prismatic Recessed SetDiffuserLouvre j

1103 (3) a13 Compact Fluorescent Lighting Fixture 28watts Prismatic Recessed SetDiffuserLouvre j

1103 (3) a14 Compact Fluorescent Lighting Fixture 38watts Prismatic Recessed SetDiffuser

1103 (4) al Compact Fluorescent Lamp (CFL) wjMedium Base, Keyless type, 7watts Surface Mounted SetPorcelain Receotacle Outlet

1103 (4) a2 Compact Fluorescent Lamp (CFL) wjMedium Base, Keyless type, 9watts Surface Mounted SetPorcelain Receotacle Outlet

1103 (4) a3 Compact Fluorescent Lamp (CFL) wjMedium Base, Keyless type, 10watts Surface Mounted SetPorcelain Receotacle Outlet

.1103 (4) a4 Compact Fluorescent Lamp (CFL) wjMedium Base, Keyless type, 11watts Surface Mounted SetPorcelain Receotacle Outlet

1103 (4) as Compact Fluorescent Lamp (CFL) wjMedium Base, Keyless type, 13watts Surface Mounted SetPorcelain Receotacle Outlet

1103 (4) a6 Compact Fluorescent Lamp (CFL) wjMedium Base, Keyless type, l6watts Surface Mounted SetPorcelain Receotacle Outlet

1103 (4) a7 Compact Fluorescent Lamp (CFL) wjMedium Base, Keyless type, l8watts Surface Mounted SetPorcelain Receotacle Outlet

1103 (4) a8 Compact Fluorescent Lamp (CFL) wjMedium Base, Keyless type, 2lwatts Surface Mounted SetPorcelain Receotacle Outlet

1103 (4) a9 Compact Fluorescent Lamp (CFL) wjMedium Base, Keyless type, 24watts Surface Mounted SetPorcelain Receotacle Outlet

1103 (4) alO Compact Fluorescent Lamp (CFL) wjMedium Base, Keyless type, 26watts Surface Mounted SetPorcelain Receotacle Outlet

1103 (4) all Compact Fluorescent Lamp (CFL) wjMedium Base, Keyless type, 28watts Surface Mounted SetPorcelain Receotacle Outlet

Page 68 VOL III

Page 130: Standardized Pay Items of Works for Civil Works Construction for

1103 (4) a12Compact Fluorescent Lamp (CFL) w/Medium Base, Keyless type,

34watts Surface Mounted SetPorcelain Receetacle Outlet

1103 (4) a13Compact Fluorescent Lamp (CFL) w/Medium Base, Keyless type,

38watts Surface Mounted SetPorcelain Receotacle Outlet

1103 (5) al Down Licht I Pinlicht Fixture w/CFL (152mm0 (6")) 7watts to 16watts Surface Mounted Set1103 (5) a2 Down Light / Pinlight Fixture w/CFL (152mm0 (6"» 7watts to 16watts w/glass cover Surface Mounted Set1103 (5) a3 Down Liaht I Pinliaht Fixture w/CFL (152mm0 (6")) 7watts to 16watts Recessed Set1103 (5) a4 Down Light / Pinlight Fixture w/CFL (152mm0 (6"» 7watts to 16watts w/glass cover Recessed Set1103 (5) bl Down Licht I Pinlicht Fixture w/CFL (203mm0 (8")) 18watts to 21watts Surface Mounted Set1103 (5) b2 Down Light / Pinlight Fixture w/CFL (203mm0 (8"» 18watts to 21watts w/glass cover Surface Mounted Set1103 (5) b3 Down Licht I Pinlicht Fixture w/CFL (203mm0 (8")) 18watts to 21watts Recessed Set1103 5) b4 Down Light / Pinliaht Fixture w/CFL 203mm0 8")) 18watts to 21watts w/glass cover Recessed Set1103 5) cl Down Licht Pinlicht Fixture w/CFL 255mm0 10" 1 - 18watts Recessed Set1103 5 c2 Down Liaht Pinliaht Fixture w/CFL 255mm0 10" 2 - 13watts Recessed Set1103 5 c3 Down Licht Pinlicht Fixture w/CFL (255mm0 (10" 2 - 18watts Recessed Set1103 5 dl Down Licht Pinliaht Fixture w/CFL 052mm (6") sauare) 7watts to 16watts Surface Mounted Set1103 (5) d2 Down Light / Pinlight Fixture w/CFL (152mm (6") square) 7watts to 16watts w/glass cover Surface Mounted Set1103 (5) d3 Down Liaht Pinliaht Fixture w/CFL (152mm (6") sauare) 7watts to 16watts Recessed Set1103 5) d4 Down Light / Pinlight Fixture w/CFL (152mm (6") sauare) 7watts to 16watts w/C1lasscover Recessed Set1103 6) al Licht Emittinc Diode (LED) Tube Iiahtina Fixture 1 - 8watts Box Type Surface Mounted Set1103 6 a2 LED Tube LiClhtinCiFixture 2 - 8watts Box Tyee Surface Mounted Set1103 6 a3 LED Tube Liahtina Fixture 3 - 8watts Box Type Surface Mounted Set1103 6 a4 LED Tube LiClhtinCiFixture 4 - 8watts Box Type Surface Mounted Set1103 6 as LED Tube Liahtina Fixture 1 - 8watts Box Type Recessed Coved Set1103 6 a6 LED Tube Lightina Fixture 2 - 8watts Box Type Recessed Coved Set1103 6 a7 LED Tube Liahtina Fixture 3 - 8watts Box Type Recessed Coved Set1103 6 a8 LED Tube Lichtina Fixture 4 - 8watts Box Type Recessed Coved Set1103 6 a9 LED Tube LiClhting Fixture 1 - 12watts Box Tyee Surface Mounted Set1103 6 a10 LED Tube Liahtina Fixture 2 - 12watts Box Tvee Surface Mounted Set1103 6 all LED Tube Liahtina Fixture 3 - 12watts Box Type Surface Mounted Set1103 6 a12 LED Tube Liahtina Fixture 4 - 12watts Box Type Surface Mounted Set1103 6 a13 LED Tube Lichtinc Fixture 1 - 12watts Box Type Recessed Coved Set1103 6 a14 LED Tube Lichtina Fixture 2 - 12watts Box Type Recessed Coved Set1103 6 a15 LED Tube Liahtina Fixture 3 - 12watts Box Tyee Recessed Coved Set1103 6 a16 LED Tube Liahtina Fixture 4 - 12watts Box Tvee Recessed Coved Set1103 6 a17 LED Tube Liahtina Fixture 1 - 16watts Box Type Surface Mounted Set1103 6 a18 LED Tube Liahtina Fixture 2 - 16watts Box Type Surface Mounted Set1103 6 a19 LED Tube Lichtinc Fixture 3 - 16watts Box Tyee Surface Mounted Set1103 (6) a20 LED Tube Liahtina Fixture 4 - 16watts Box Type Surface Mounted Set1103 (6) a21 LED Tube Liahtina Fixture 1 - 16watts Box Type Recessed ICoved Set

Page 69 VOL III

Page 131: Standardized Pay Items of Works for Civil Works Construction for

1103 (6) a22 LED Tube Liahtina Fixture 2 - 16watts Box Type Recessed Caved Set1103 (6) a23 LED Tube Liahtinq Fixture 3 - 16watts Box Tvpe Recessed Caved Set1103 (6) a24 LED Tube Liqhting Fixture 4 - 16watts Box Tvoe Recessed Caved Set

1103 (6) bl LED Tube Lighting Fixture 1 - 8wattsw/Prismatic

Surface Mounted SetDiffuser

1103 (6) b2 LED Tube Lighting Fixture 2 - 8wattsw/Prismatic

Surface Mounted SetDiffuser

1103 (6) b3 LED Tube Lighting Fixture 3 - 8wattsw/Prismatic

Surface Mounted SetDiffuser

1103 (6) b4 LED Tube Lighting Fixture 4 - 8watts w/PrismaticSurface Mounted Set

Diffuser1103 (6) b5 LED Tube Lighting Fixture 1 - 8watts w/Prismatic

Recessed ICoved SetDiffuser

1103 (6) b6 LED Tube Lighting Fixture 2 - 8wattsw/Prismatic

Recessed ICoved SetDiffuser

1103 (6) b7 LED Tube Lighting Fixture 3 - 8wattsw/Prismatic

Recessed ICoved SetDiffuser

1103 (6) b8 LED Tube Lighting Fixture 4 - 8wattswiPrismatic

Recessed lCoved SetDiffuser

1103 (6) b9 LED Tube Lighting Fixture 1 - 12wattswiPrismatic

Surface Mounted SetDiffuser

1103 (6) bl0 LED Tube Lighting Fixture 2 - 12wattsw/Prismatic

Surface Mounted SetDiffuser

1103 (6) b11 LED Tube Lighting Fixture 3 - 12wattsw/Prismatic

Surface Mounted SetDiffuser

1103 (6) b12 LED Tube Lighting Fixture 4 - 12wattsw/Prismatic

Surface Mounted SetDiffuser

1103 (6) b13 LED Tube Lighting Fixture 1 - 12wattsw/Prismatic

Recessed ICoved SetDiffuser1103 (6) b14 LED Tube Lighting Fixture 2 - 12watts

w/PrismaticRecessed ICoved Set

Diffuser1103 (6) b15 LED Tube Lighting Fixture 3 - 12watts

wiPrismaticRecessed ICoved Set

Diffuser1103 (6) b16 LED Tube Lighting Fixture 4 - 12watts

w/PrismaticRecessed ICoved Set

Diffuser

1103 (6) b17 LED Tube Lighting Fixture 1 - 16wattsw/Prismatic

Surface Mounted SetDiffuser

1103 (6) b18 LED Tube Lighting Fixture 2 - 16wattsw/Prismatic

Surface Mounted SetDiffuser

1103 (6) b19 LED Tube Lighting Fixture 3 - 16wattsw/Prismatic

Surface Mounted SetDiffuser

1103 (6) b20 LED Tube Lighting Fixture 4 - 16wattsw/Prismatic

Surface Mounted SetDiffuser

Page 70 VOL III

Page 132: Standardized Pay Items of Works for Civil Works Construction for

1103 (6) b21 LED Tube Lighting Fixture 1 - 16wattsw/Prismatic

Recessed ICoved SetDiffuser

1103 (6) b22 LED Tube Lighting Fixture 2 - 16wattswiPrismatic

Recessed ICoved SetDiffuser

1103 (6) b23 LED Tube Lighting Fixture 3 - 16wattsw/Prismatic

Recessed ICoved SetDiffuser

1103 (6) b24 LED Tube Lighting Fixture 4 - 16wattsw/Prismatic

Recessed ICoved SetDiffuser

Mirrorized

1103 (6) cl LED Tube Lighting Fixture 1 - 8wattsAluminum 300 x 600mm Surface

SetLouvre, Mounted

I rnrr~r vneMirrorized

1103 (6) c2 LED Tube Lighting Fixture 2 - 8wattsAluminum 300 x 600mm Surface

SetLouvre, Mounted

I rnrrpr vn~Mirrorized

1103 (6) c3 LED Tube Lighting Fixture 2 - 8wattsAluminum 600 x 600mm Surface

SetLouvre, Mounted

I rnrr~r IvneMirrorized

1103 (6) c4 LED Tube Lighting Fixture 3 - 8wattsAluminum 600 x 600mm Surface

SetLouvre, Mounted

rnrr~r IvneMirrorized

1103 (6) cS LED Tube Lighting Fixture 4 - 8wattsAluminum 600 x 600mm Surface Set

Louvre, MountedrnITPr Tvn~Mirrorized

1103 (6) c6 LED Tube Lighting Fixture 1 - 8wattsAluminum 300 x 600mm Recessed Set

Louvre,mrrer TvoeMirrorized

1103 (6) c7 LED Tube Lighting Fixture 2 - 8wattsAluminum 300 x 600mm Recessed Set

Louvre,'ITPr Tvn~

Mirrorized

1103 (6) c8 LED Tube Lighting Fixture 2 - 8wattsAluminum 600 x 600mm Recessed Set

Louvre,DrrerTvnp

Page 71 VOL III

Page 133: Standardized Pay Items of Works for Civil Works Construction for

Mirrorized

1103 (6) c9 LED Tube Lighting Fixture 3 - 8wattsAluminum

600 x 600mm Recessed SetLouvre,

I rnTTPr I VOPMirrorized

1103 (6) c10 LED Tube Lighting Fixture 4 - 8watts Aluminum600 x 600mm Recessed Set

Louvre,I rnTTPr I VI1PMirrorized

1103 (6) cll LED Tube Lighting Fixture 1 - 12watts Aluminum 300 x 1200mm SurfaceSet

Louvre, Mounted- -I rnrn'r IvnpMirrorized

1103 (6) c12 LED Tube Lighting Fixture 2 - 12wattsAluminum 300 x 1200mm Surface

SetLouvre, MountedI mTTer TvoeMirrorized

1103 (6) c13 LED Tube Lighting Fixture 2 - 12watts Aluminum 600 x 1200mm SurfaceSet

Louvre, MountedI rnTTPr TvnPMirrorized

1103 (6) c14 LED Tube Lighting Fixture 3 - 12wattsAluminum 600 x 1200mm Surface

SetLouvre, Mounted

I rnTTPr TvnpMirrorized

1103 (6) elS LED Tube Lighting Fixture 4 - 12watts Aluminum 600 x 1200mm SurfaceSet

Louvre, MountedI rnrrpr TvoeMirrorized

1103 (6) c16 LED Tube Lighting Fixture 1 - 12watts Aluminum300 x 1200mm Recessed Set

Louvre,Trnffpr Tvnp

Mirrorized

1103 (6) el7 LED Tube Lighting Fixture 2 - 12wattsAluminum

300 x 1200mm Recessed SetLouvre,OTTerTvoe

Mirrorized

1103 (6) c18 LED Tube Lighting Fixture 2 - 12wattsAluminum

600 x 1200mm Recessed SetLouvre,

I rnTTPr Tvnp

Page 72 VOL III

Page 134: Standardized Pay Items of Works for Civil Works Construction for

Mirrorized

1103 (G) c19 LED Tube Lighting Fixture 3 - 12watts Aluminum GOOx 1200mm Recessed SetLouvre,

Irarrer IvoeMirrorized

1103 (G) c20 LED Tube Lighting Fixture 4 - 12watts Aluminum GOOx 1200mm Recessed SetLouvre,

Irarrer IvoeMirrorized

1103 (G) c21 LED Tube Lighting Fixture 1 - 1Gwatts Aluminum 300 x 1200mm Surface SetLouvre, Mounted.~

I rnrrpr IVnPMirrorized

1103 (G) c22 LED Tube Lighting Fixture 2 - 1Gwatts Aluminum 300 x 1200mm Surface SetLouvre, MountedIrOTTPrIvnpMirrorized

1103 (G) c23 LED Tube Lighting Fixture 2 - 1Gwatts Aluminum GOOx 1200mm Surface SetLouvre, MountedIrarrer IvoeMirrorized

1103 (G) c24 LED Tube Lighting Fixture 3 - 1Gwatts Aluminum GOOx 1200mm Surface SetLouvre, MountedImTTer vaeMirrorized

1103 (G) c25 LED Tube Lighting Fixture 4 - 1Gwatts Aluminum GOOx 1200mm Surface SetLouvre, MountedIrarrer voeMirrorized

1103 (G) c2G LED Tube Lighting Fixture 1 - 1Gwatts Aluminum 300 x 1200mm Recessed SetLouvre,Irarrer IvoeMirrorized

1103 (G) c27 LED Tube Lighting Fixture 2 - 1Gwatts Aluminum· 300 x 1200mm Recessed SetLouvre,Irarrer IvoeMirrorized

1103 (G) c28 LED Tube Lighting Fixture 2 - 1Gwatts Aluminum GOOx 1200mm Recessed SetLouvre,

Irarrer Ivae

Page 73 VOL III

Page 135: Standardized Pay Items of Works for Civil Works Construction for

Mirrorized

1103 (G) c29 LED Tube Lighting Fixture 3 - lGwatts Aluminum GOOx 1200mm Recessed SetLouvre,

I mTTer TveeMirrorized

1103 (G) c30 LED Tube Lighting Fixture 4 - lGwatts Aluminum GOOx 1200mm Recessed SetLouvre,

I mTTer Tvoe

1103 (G) dl LED Tube Lighting Fixture 1 - 8wattsIndustrial Surface Mounted Set

Tvoe

1103 (G) d2 LED Tube Lighting Fixture 2 - 8wattsIndustrial Surface Mounted Set

Tvee

1103 (G) d3 LED Tube Lighting Fixture 3 - 8wattsIndustrial Surface Mounted Set

Tvoe

1103 (G) d4 LED Tube Lighting Fixture 4 - 8wattsIndustrial Surface Mounted Set

Tvoe

1103 (G) dS LED Tube Lighting Fixture 1 - 12watts Industrial Surface Mounted SetTvoe

1103 (G) dG LED Tube Lighting Fixture 2 - 12wattsIndustrial Surface Mounted Set

Tvee

1103 (G) d7 LED Tube Lighting Fixture 3 - 12wattsIndustrial Surface Mounted Set

Tvoe

1103 (G) d8 LED Tube Lighting Fixture 4 - 12wattsIndustrial Surface Mounted Set

Tvee

1103 (G) d9 LED Tube Lighting Fixture 1 - lGwatts Industrial Surface Mounted SetTvee

1103 (G) dl0 LED Tube Lighting Fixture 2 - lGwattsIndustrial Surface Mounted Set

Tvee

1103 (G) d11 LED Tube Lighting Fixture 3 - lGwattsIndustrial Surface Mounted Set

Tvee

1103 (G) d12 LED Tube Lighting Fixture 4 - lGwatts Industrial Surface Mounted SetTvee

1103 (7) al LED Bulb w/Medium Base, Keyless Type, Porcelain Receptacle Outlet S.Swatts E27 Base Surface Mounted Set

1103 (7) a2 LED Bulb w/Medium Base, Keyless Type, Porcelain Receptacle Outlet 7watts E27 Base Surface Mounted Set

1103 (7) a3 LED Bulb w/Medium Base, Keyless Type, Porcelain Receptacle Outlet 9watts E27 Base Surface Mounted Set

1103 (7) a4 LED Bulb w/Medium Base, Keyless Type, Porcelain Receptacle Outlet 10watts E27 Base Surface Mounted Set

1103 (7) as LED Bulb w/Medium Base, Keyless Type, Porcelain Receptacle Outlet 18watts E27 Base Surface Mounted Set

Page 74 VOL III

Page 136: Standardized Pay Items of Works for Civil Works Construction for

1103 8 a1 Down Liaht Pinliaht Fixture w LED 76.2mm0 '3" ,) 2watts to 4watts Recessed Set1103 8 a2 Down Liaht Pinliaht Fixture w LED 100mm0 I4" 4watts to 5.5watts Recessed Set1103 8 a3 Down LiClht Pinliaht Fixture w LED 152mm0 I6" 5.5watts to 9watts Recessed Set1103 8 a4 Down Liaht Pinliaht Fixture w LED 203mm0 I8'" 9watts to 12watts Recessed Set1103 8 a5 Down LiQht PinliQht Fixture w LED 100mm (4") SQuare) 5.5watts Recessed Set1103 8 a6 Down Liaht Pinliaht Fixture w LED 152mm (6") Sauare ) 9watts Recessed Set1103 8 a7 Down LiQht PinliClht Fixture w LED 203mm (8") SQuare) 12watts Recessed Set1103 8 a8 Down Liaht Pinliaht Fixture wILED Bulb (152mm0 (6")) 5.5watts to 10watts Recessed Set1103 (8) a9 Down Light I Pinlight Fixture wiLED Bulb (152mm0 (6"» 5.5watts to 10watts w/glass cover Recessed Set

1103 (8) a10 Down Light I Pinlight Fixture wiLED Bulb (152mm (6") Square) 5.5watts to 10watts Recessed Set

1103 (8) all Down Light I Pinlight Fixture wiLED Bulb (152mm (6") Square) 5.5watts to 10watts w/glass cover Recessed Set1103 8) a12 Down Liaht I Pinliaht Fixture wILED Bulb (203mm (8")) 12watts to 18watts Recessed Set1103 (8) a13 Down Light I Pinlight Fixture wiLED Bulb (203mm (8"» 12watts to 18watts w/glass cover Recessed Set

1103 (9) a1 Self contained Double Sided Exit Sign, Maintained 3rs duration wi 8watts, T5 Polycarbonate Recessed Setli'lmn

1103 (9) a2Self contained Single Sided Exit Sign, Maintained 3rs duration wi

8watts, T6 Polycarbonate wall mounted Setfluorescent lamo

1103 (9) a3Self contained Emergency Lighting Pack, Non-Maintained 3hrs

2 - 10watts Wall Mounted Setduration with Ouartz Haloaen Lamos

1103 (9) a4Self contained Emergency Lighting Pack, Non-Maintained 3hrs

6watts, 230volts Wall Mounted Setduration with 2- LED Lamos

Stainless SteelBracket Bodyand Ribbed

1103 (10) Obstruction Lighting Fixture 70w/80watts HPS-E borosilicate Surface or Pole Mounted Setglass withwire retainingharness

1103 (11 a1 Hiah Bav Aluminum Reflector Dome Luminaire 250w. HPS MH Surface Mounted Set1103 11 a2 HiClhBay Aluminum Reflector, Dome Luminaire 400w, HPS MH Surface Mounted Set1103 12 a1 Die-Cast Aluminum Floodliaht with electrocoat oaint finish 250w. HPS MH Wall Mounted Set1103 12 a2 Die-Cast Aluminum Floodliaht with electrocoat paint finish 400w. HPS MH Wall Mounted Set

Die-Cast Aluminum Spot - Floodlight with electrocoat gray paint1103 (12) a3 finish inside and out. Enclosed, gasketed, filtered optical with 400w, HPS IMH Wall Mounted Set

aluminum reflector and temoered class closure

1103 (13)Wall Type Luminaire (Bracket Light) with acrylic polycarbonate globe

Setdiffuser comolete with all accessories

Page 75 VOL III

Page 137: Standardized Pay Items of Works for Civil Works Construction for

"tUlllm ¥ ;SIf'e 'Ill1200 1 Variable Refri erant Flow (VRF) inverter tvoe Set1200 2 al Fan Coil Unit FCU) Set1200 2 a2 Fan Coil Unit FCU) wall mounted tvoe Set.1200 2 a3 Fan Coil Unit FCU ceilinq mounted Set •1200 2 a4 Fan Coil Unit FCU floor standinq tvoe Set1200 2 as Fan Coil Unit FCU ceilina cassette tvoe Set1200 2 a6 Fan Coil Unit FCU duct tvoe Set1200 3 al Air Cooled Condensina Unit ACCU Set1200 3 a2 Air Cooled Condensina Unit ACCU Modular Tyoe, 8HP Set1200 3 a3 Air Cooled Condensinq Unit ACCU Modular Tvoe 10HP Set1200 3 a4 Air Cooled Condensinq Unit ACCU Modular Tvoe 12HP Set1200 3 as Air Cooled Condensina Unit (ACCU) Modular Type, 14HP Set1200 3 a6 Air Cooled Condensina Unit (ACCU Modular Tvoe 16HP Set1200 4 al Packaae tvoe Airconditionina unit PACU Set1200 4 a2 Packaqe type Airconditioninq unit PACU wall mounted Set1200 4 a3 Packaae tvoe Airconditionina unit PACU floor standinq type Set1200 4 a4 Packaae tvoe Airconditionina unit PACU ceilina mounted Set1200 4 as Packaqe type Airconditioninq unit PACU wall mounted inverter Set1200 (4) a6 Packaqe tvoe Airconditioninq unit PACU standinq type inverter Set

1200 (4) a7 Package type Airconditioning unit PACU ceiling mounted inverter Set

1200 (5) al Window tvoe airconditionina unit Set1200 (5) a2 Window type airconditioninq unit non-inverter tvoe Set1200 (5 a3 Window tvoe airconditioninq unit unit inverter type Set1200 (6 Diffusers Piece1200 (7 al Suoolv Ceilina Diffuser (SCD) 300mm x 300mm Piece1200 (7) a2 Suooly Ceilinq Diffuser (SCD) 500mm x 500mm Piece1200 (8) al Return Ceilina Diffuser (RCD) 300mm x 300mm Piece1200 8 a2 Return Ceilinq Diffuser (RCD) 3S0mm x 350mm Piece1200 9 al Suooly Linear Diffuser (SLD) 1600mm x 100mm Piece1200 9 a2 Supply Linear Diffuser (SLD) 900mm x 100mm Piece1200 (9 a3 Suoolv Linear Diffuser (SLD) 600mm x 200mm Piece1200 9 a4 Supply Linear Diffuser (SLD 350mm x 200mm Piece

1200 10 al Return Linear Diffuser (RLD 1350 x 100mm Piece1200 10 a2 Return Linear Diffuser RLD 900 x 100mm Piece1200 10 a3 Return Linear Diffuser RLD 600 x 200mm Piece1200 10 a4 Return Linear Diffuser RLD 750 x 100mm Piece1200 10 as Return Linear Diffuser RLD 500 x 200mm Piece1200 (10) a6 Return Linear Diffuser (RLD 200 x 175mm Piece___ ~~",,,,,. __ ~,,,,u,"'· -.--,.

Page 76 VOL III

Page 138: Standardized Pay Items of Works for Civil Works Construction for

1200 11) a1 Exhaust Air Grilles IEAG Piece

1200 11 a2 Exhaust Air Grilles EAG 4S0mm x 300mm Piece

1200 11 a3 Exhaust Air Grilles EAG 400mm x 400mm Piece

1200 11 a4 Exhaust Air Grilles EAG) 3S0mm x 300mm Piece

1200 11 as Exhaust Air Grilles EAG) 300mm x 300mm Piece

1200 11 a6 Exhaust Air Grilles EAG 300mm x 2S0mm Piece

1200 11 a7 Exhaust Air Grilles EAG 300mm x 200mm Piece

1200 11 a8 Exhaust Air Grilles EAG 2S0mm x 2S0mm Piece

1200 11 a9 Exhaust Air Grilles EAG 2S0mm x 200mm Piece

1200 11 alO Exhaust Air Grilles EAG 200mm x 200mm Piece

1200 (11 all Exhaust Air Grilles EAG 200mm x lS0mm Piece

1200 (11 a12 Exhaust Air Grilles / EAG lS0mm x lS0mm Piece

1200 11) a13 Exhaust Air Grilles (EAG lS0mm x 100mm Piece

1200 12) a1 Fresh Air Grille Piece

1200 12 a2 FAG lS0mm x 100mm lS0mm x 100mm Piece

1200 12 a3 FAG 100mm x 100mm 100mm x 100mm Piece

1200 13 al Backdraft Damoer Piece

1200 13 a2 Backdraft Damoer 2S0mm x 2S0mm Piece

1200 13 a3 Backdraft Damper 2S0mm x 200mm Piece

1200 13 a4 Backdraft Damper 200mm x 200mm Piece

1200 13 as Backdraft Damoer 200mm x lS0mm Piece

1200 13 a6 Backdraft Damper lS0mm x lS0mm Piece

1200 13 a7 Backdraft Damoer lS0mm x 100mm Piece

1200 14 a Ventilatina Eauioment Set

1200 I 14 b1 Oscillatina Stand Fan Set

1200 I 14 b2 Oscillatina Wall Fan Set

1200 14) b3 Oscillatino Ceilina Fan Set

1200 14) c Stand Fan Industrial Tvoe Set

1200 14 d1 Prooeller Wall Mounted Fan Set

1200 14 d2 Prooeller Ceilina ITutubj) Fan Set

1200 14 d3 Prooeller Tube Axial Roof Mounted.

Set

1200 14 e1 Exhaust fan, ceilina cassette Set

1200 14 e2 Exhaust fan, wall mounted Set

1200 14 e3 Exhaust fan. wall mounted Industrial Tvoe Set

1200 14 e4 Exhaust Fan,Tubular In Line Set

1200 14 f Suoolv fan ceilina cassette Set

1200 14 01 Centrifuoal Cabinet in line Ducted tvoe (tcn Set

1200 (14) a2 Centrifuaal Backward Incline Set

1200 (14) i Induced Jet Fan Set"'~.,.,.-

Page 77 VOL III

Page 139: Standardized Pay Items of Works for Civil Works Construction for

1200 (14) 11 Coolino Tower/Chiller Set1200 (14) 12 Coolina Tower Set1200 (4) 13 Chiller Set

1200 (15)1 Refrigirant Copper Pipe, Refrigirant Copper Pipe Fittings & Refrigirant Linear MeterCoooer Pioe Insulation

1200 (16) a1 Refrioirant Copper Pipe Linear Meter1200 16 a2 Refrioirant Coooer Pioe 6.35 mm0 tvoe L Hard Drawn Linear Meter1200 16 a3 Refriairant Coooer Pioe 9.52 mm0 tvoe L Hard Drawn Linear Meter1200 16 a4 Refrioirant Coooer Pioe 12.7 mm0 type L Hard Drawn Linear Meter1200 16 as Refriairant Coooer Pioe 15.88 mm0 tvoe L Hard Drawn Linear Meter1200 16 a6 RefriClirant Copper Pipe 19.05 mm0 :vpe L Hard Drawn Linear Meter1200 16 a7 Refrioirant Coooer Pioe 22.2 mm0 :voe L Hard Drawn Linear Meter1200 16 a8 Refriairant Coooer Pioe 28.58 mm0 :voe L Hard Drawn Linear Meter1200 16 a9 Refriairant Coooer Pioe 34.93 mm0 tvoe L Hard Drawn Linear Meter1200 16 a10 Refrioirant Coooer Pipe 41.28 mm0 tvoe L Hard Drawn Linear Meter1200 17 a1 Refriairant Coooer Pioe Fittinas Piece1200 17 a2 RefriClirant Copper Pipe Fittinos 6.35 mm0 Copper Elbow 900 Piece

'1200 17 a3 Refrioirant Coooer Pioe Fittinos 9.52 mm0 Coooer Elbow 900 Piece1200 17 a4 Refriairant Coooer Pioe Fittinas 12.7 mm0 Cooper Elbow 900 Piece1200 17 as Refrioirant Coooer Pioe Fittinos 15.88 mm0 Copper Elbow 900 Piece1200 17 a6 Refriairant Coooer Pioe Fittinas 19.05 mm0 Coooer Elbow 900 Piece1200 17 a7 Refrioirant Cooper Pipe Fittinos 22.2 mm0 Copper Elbow 900 Piece1200 17 a8 Refriairant Coooer Pioe Fittinas 28.58 mm0 Coooer Elbow 900 Piece1200 17 a9 RefriClirant Copper Pipe Fittinos 34.93 mm0 Copper Elbow 900 Piece1200 17 a10 Refriairant Cooper Pioe Fittinas 41.28 mm0 Cooper Elbow 900 Piece1200 18 a1 Branch Joint CMY-Y302-G2 Piece1200 18 a2 Branch Joint CMY-Y202-G2 Piece1200 18 a3 Branch Joint CMY-Y102L-G2 Piece1200 18 a4 Branch Joint CMY-Y102S-G2 Piece1200 (8) as Branch Joint (Header) CMY-Y108-G Piece1200 (9) a1 Refrioirant Coooer Pioe Insulation Linear Meter

1200 (19) a2 Refrigirant Copper Pipe Insulation 6.35 mm0 X 3/4" thk Rubber Insulation Linear Meter

1200 (19) a3 Refrigirant Copper Pipe Insulation 9.52 mm0 X 3/4" thk Rubber Insulation Linear Meter

1200 (19) a4 Refrigirant Copper Pipe Insulation 12.7 mm0 X 3/4" thk Rubber Insulation Linear Meter

1200 (19) as Refrigirant Copper Pipe Insulation 15.88 mm0 X 3/4" thk Rubber Insulation Linear Meter

1200 (19) a6 Refrigirant Copper Pipe Insulation 19.05 mm0 X 3/4" thk Rubber Insulation Linear Meter

1200 (19) a7 Refrigirant Copper Pipe Insulation 22.2 mm0 X 3/4" thk Rubber Insulation Linear Meter

Page 78 VOL II!

Page 140: Standardized Pay Items of Works for Civil Works Construction for

1200 (19) a8 Refrigirant Copper Pipe Insulation 28.58 mm0 X 3/4" thk Rubber Insulation Linear Meter

1200 (19) a9 Refrigirant Copper Pipe Insulation 34.93 mm0 X 3/4" thk Rubber Insulation Linear Meter

1200 (19) al0 Refrigirant Copper Pipe Insulation 41.28 mm0 X 3/4" thk Rubber Insulation Linear Meter

1200 19 all Refriairant Coooer Pioe Insulation 15 mm0 X 1/2" thk Rubber Insulation Linear Meter1200 19 a12 Refriairant Coooer Pioe Insulation 20 mm0 X 1 2" thk Rubber Insulation Linear Meter1200 19 a13 Refriairant Coooer Pioe Insulation 25 mm0 X 1 2" thk Rubber Insulation Linear Meter1200 19 a14 Refriairant Coooer Pioe Insulation 32 mm0 X 1 2" thk Rubber Insulation Linear Meter1200 19) a15 Refriairant Coooer Pioe Insulation 50 mm0 X V2" thk Rubber Insulation Linear Meter1200 2m Ducts and Duct Insulation Linear Meter1200 21 Rectanaular Galvanized Steel Sheet Air Duct. Suoolv & Return Linear Meter1200 22 al Duct Fabrication (GI Sheet) aauae 26 Linear Meter1200 22 a2 Duct Fabrication (GI Sheet) aauae 24 Linear Meter1200 22 a3 Duct Fabrication (GI Sheet) aauae 22 Linear Meter1200 22 a4 Duct Fabrication (GI Sheet) aauae 20 Linear Meter1200 23 al Aluminum Flexible Duct Linear Meter1200 23 a2 Aluminum Flexible Duct 100 mm0 Linear Meter1200 23 a3 Aluminum Flexible Duct 150 mm0 Linear Meter1200 23 a4 Aluminum Flexible Duct 200 mm0 Linear Meter1200 23 as Aluminum Flexible Duct 250 mm0 Linear Meter1200 23 a6 Aluminum Flexible Duct 300 mm0 Linear Meter1200 23 a7 Aluminum Flexible Duct 350 mm0 Linear Meter1200 24 al Aluminum Flexible Duct Connector Piece1200 24 a2 Aluminum Flexible Duct Connector 100 mm0 Piece1200 24 a3 Aluminum Flexible Duct Connector 150 mm0 Piece1200 24 a4 Aluminum Flexible Duct Connector 200 mm0 Piece1200 24 as Aluminum Flexible Duct Connector 250 mm0 Piece1200 24 a6 Aluminum Flexible Duct Connector 300 mm0 Piece1200 24 a7 Aluminum Flexible Duct Connector 350 mm0 Piece1200 25 Rectanaular Duct Work Insulation Sauare Meter

1200 (26) Fiberglass Insulation 25mm0, 32 kg/m3 wiSquare Meter

aluminum foil

ITEM.1201·· .•·wATER:I?UMI?ING:SYsTEM •

ablb2b3

Page 79 VOL III

Page 141: Standardized Pay Items of Works for Civil Works Construction for

1201 (2 c Booster pump with control Set1201 2 d Jet pump with control Set1201 3 a Water tank Set1201 3 b1 Overhead Tank Stainless Set1201 3 b2 Overhead Tank Galvanized Iron Set'1201 3 b3 Overhead Tank Polvethvlene Set1201 4 b1 Pneumatic Stainless Set I

1201 (4 b2 Pneumatic Galvanized Iron Set1201 (5 Air Compressor Set1201 6 a Valves Piece1201 6 b1 Gate Valve 12mm dia. Piece1201 6 b2 Gate Valve 20mm dia. Piece1201 6 b3 Gate Valve 25mm dia. Piece1201 6 b4 Gate Valve 32mm dia. Piece1201 6 b5 Gate Valve 40mm dia. Piece1201 6 b6 Gate Valve 50mm dia Piece1201 6 b7 Gate Valve 65mm dia. Piece1201 6 b8 Gate Valve 75mm dia Piece1201 6 b9 Gate Valve 100mm dia Piece1201 6 c1 Check Valve 12mm dia. Piece1201 6 c2 Check Valve 20mm dia. Piece1201 6 c3 Check Valve 25mm dia. Piece1201 6 c4 Check Valve 32mm dia. Piece1201 6 c5 Check Valve 40mm dia. Piece1201 6 c6 Check Valve 50mm dia Piece1201 6 c7 Check Valve 65mm dia. Piece1201 6 c8 Check Valve 75mm dia Piece1201 6 c9 Check Valve 100mm dia Piece1201 6 d1 Foot Valve 25mm dia. Piece1201 6 d2 Foot Valve 32mm dia. Piece1201 6 d3 Foot Valve 40mm dia. Piece1201 6 d4 Foot Valve 50mm dia Piece1201 6 d5 Foot Valve 65mm dia. Piece1201 6 d6 Foot Valve 75mm dia Piece1201 6 d7 Float Valve 25mm dia. Piece1201 6 d8 Float Valve 32mm dia. Piece1201 (6) d9 Float Valve 40mm dia. Piece1201 (6) d10 Float Valve 50mm dia Piece1201 (6 dll Float Valve 65mm dia. Piece

Page 80 VOL III

Page 142: Standardized Pay Items of Works for Civil Works Construction for

·11111 '181· "1202(iT Automatic Water Springkler System Lumo Sum1202 (2) a Fire Pump complete with control and standard accessories Set1202 2 b Jockev Pumo comolete with control and standard accessories Set1202 3 a1 Sprinkler Head. upriaht 20 mm dia. Piece1202 3 a2 Sprinkler Head. oendent 20 mm dia. Piece1202 3 a3 Sprinkler Head. wall 20 mm dia. Piece1202 3 bl Alarm check valve 80 mm dia Piece1202 3 b2 Alarm check valve 100 mm dia Piece1202 3 b3 Alarm check valve 150 mm dia Piece1202 3 c1 Flow meter 80 mm dia Piece1202 3 c2 Flow meter 100 mm dia Piece1202 3) c3 Flow meter 150 mm dia Piece1202 3) dl as & Y Gate valve 175 psi 80 mm dia Piece1202 3 d2 as & Y Gate valve 175 psi 100 mm dia Piece1202 3 d3 as & Y Gate valve 175 osi 150 mm dia Piece1202 3 el Pressure aauae 25 mm dia Piece1202 3 e2 Pressure gauge 32 mm dia Piece1202 3 e3 Pressure aauae 40 mm dia Piece1202 3 e4 Pressure aauae 50 mm dia Piece1202 3 f1 Pressure relief valve 23 mm dia Piece1202 3 f2 Pressure relief valve 32 mm dia Piece1202 (3) f3 Pressure relief valve 150 mm dia Piece1202 (3) gl Floor control valve 100 mm dia Piece1202 3 a2 Floor control valve 150 mm dia Piece1202 3 hl Inspector test valve 25 mm dia Piece1202 3 h2 inspector test connector 25 mm dia Piece1202 4 al B.1. Pipes 25 mm dia. Lenath1202 4 a2 B.I. Pipes 32 mm dia. Lenath1202 4 a3 B.1. Pioes 40 mm dia. Length1202 4 a4 B.I. Pipes 50 mm dia. Length1202 4 as B.1. Pipes 65 mm dia. Lenath1202 4 a6 B.1. Pipes 75 mm dia. Lenath1202 4 a7 B.1. Pioes 100 mm dia. Lenath1202 4) a8 B.1. Pipes 150 mm dia. Lenath1202 4) bl B.1. 90 elbow 25 mm dia. Piece1202 4 b2 B.1. 90 elbow 32 mm dia. Piece1202 4 b3 B.1. 90 elbow 40 mm dia. Piece1202 4 b4 B.1. 90 elbow 50 mm dia. Piece1202 (4 b5 B.1. 90 elbow 65 mm dia. Piece1202 (4) b6 B.1. 90 elbow 80 mm dia Piece

Page 81 VOL III

Page 143: Standardized Pay Items of Works for Civil Works Construction for

1202 4 b7 B.1. 90 elbow 100 mm dia. Piece

1202 4 b8 B.1. 90 elbow 150 mm dia. Piece

1202 4 cl B.1. Tee 25 mm dia. Piece

1202 4 c2 B.1. Tee 32 mm dia. Piece

1202 4 c3 B.1. Tee 40 mm dia. Piece

1202 4 c4 B.1. Tee 50 mm dia. Piece

1202 4 c5 B.1. Tee 65 mm dia. Piece'

1202 4 c6 B.1. Tee 80 mm dia Piece

1202 4 c7 B.1. Tee 100 mm dia. Piece

1202 4 c8 B.1. Tee 150 mm dia. Piece

1202 5 al Bell Reducer 25mm dia x 12mm dia 25715 mm dia. Piece

1202 5 a2 Bell Reducer 32mm dia x 25mm dia 32 25 mm dia. Piece

1202 5 a3 Bell Reducer 40mm dia x 32mm dia 40 32 mm dia. Piece

1202 5 a4 Bell Reducer 50mm dia x 40mm dia 50 40 mm dia. Piece

1202 5 as Bell Reducer 65mm dia x 50mm dia 65 50 mm dia. Piece

1202 5 a6 Bell Reducer 80mm dia x 65mm dia 80 65 mm dia Piece

1202 5 a7 Bell Reducer 100mm dia x 80mm dia 100/80 mm dia. Piece

1202 5 a8 Bell Reducer 150mm dia x 100mm dia 150T100 mm dia. Piece

1202 6 al Blind Flanae 50 mm dia. Piece

1202 6 a2 Blind Flanae 65 mm dia. Piece

1202 6 a3 Blind Flanae 75 mm dia. Piece

1202 6 a4 Blind Flanae 100 mm dia. Piece

1202 6 as Blind Flanae 150 mm dia. Piece

1202 6 bl SliD Flanoe 50 mm dia. Piece

1202 6 b2 SliD Flanae 65 mm dia. Piece

1202 6 b3 SliD Flanae 75 mm dia. Piece

1202 6 b4 SliD Flanoe 100 mm dia. Piece

1202 6 b5 SliD Flanae 150 mm dia. Piece

1202 7 al Riser nioole 25 mm dia. Piece

1202 7 a2 Riser nioole 32 mm dia. Piece

1202 7 a3 Riser nioole 40 mm dia. Piece

1202 7 a4 Riser nioole 50 mm dia. Piece

1202 8 al Threadolet 25 mm dia. Piece

1202 8 a2 Threadolet 32 mm dia. Piece

1202 8 a3 Threadolet 40 mm dia. Piece

1202 8 a4 Threadolet 50 mm dia. Piece

1202 9 al Pioe sleeve 65 mm dia. Piece

1202 9 a2 Pioe sleeve 75 mm dia. Piece

1202 9 a3 Pioe sleeve 100 mm dia. Piece

1202 (9) a4 Pioe sleeve 150 mm dia. Piece

1202 (10) Fire hose valve siames 150mm dia x 2w x 65mm dia with caD 150 mm dia. Set

1202 (11) Fire hose cabinet Set, ---'- __ ' __-0._.-'" .. ...... - "-"~-"._" ._- •....-...•---- ...---. ____..___~ .._.h_.'_·.~·.·~ _··0.' ____ ···••--'.,·· •..___ ._.___ ..•• _" ___ m'_"~

_ ... _____ •.•.... __ • __ •• _____ h __ ._ . _____ • __ .---..__ ._~. ____ ~ .. _. ~._. __ .•_ ~_'_""'_M' _____

Page 82 VOL III

Page 144: Standardized Pay Items of Works for Civil Works Construction for

1202 12) a1 Fire Extinqusher ABC with bracket 10lbs Set1202 12) a2 Fire Extinqusher ABC with bracket 20 Ibs Set1202 12) a3 Fire Extinqusher C02/HCFC123 with bracket 10 Ibs Set1202 (12) a4 Fire Extinqusher C02/HCFC123 with bracket 20 Ibs Set1202 (12) a5 Fire Extinqusher C02/HCFC123 wheeled type 50 Ibs Set

Len thMeter

SetSet

Piece

SetPiece

Len thMeter

Len thPiece

. SetPiece

Len thLen thLen thLen th

CoCoCoCo

12 mm dia.15 mm dia.20 mm dia.25 mm dia.

Electric ElevatorTraction or H draulic Machine and CarHoistway Doors, Counterweights, Guide Rails, Annunciators, and HallPosition IndicatorsElectrical Wires and ConduitsElectrical Wires and Conduits

Machine Electric DumbwaiterCar Door and CableElectric Wires and ConduitsElectric Wires and Conduits

1206 21206 3

Page 83 VOLUME III

Page 145: Standardized Pay Items of Works for Civil Works Construction for

12081208120812081208120812081208

Page 84

38 mm dia.50 mm dia.38 mm dia.50 mm dia.

150mm x 50mm19 mm

alid YalUe '

SetLen thPiece

MeterMeterMeterMeterMeterMeterMeterMeter

Lum SumSetSetSetSetSetSetSetSetSetSetSet

VOLUME III

Page 146: Standardized Pay Items of Works for Civil Works Construction for

:'"'"-PYalues" lass,,_1211 (1) a1 Data Cabinet Wall type Set1211 (1) a2 Data Cabinet Free standing . Set1211 (2) a1 Distribution Frame Panel Sub Set ,1211 (2) a2 Distribution Frame Panel Main .

Set1211 (3) Terminal Block Set1211 4 UTP patch Panel Set1211 5 Fiber Manaqement Panel Set1211 6 a1 UTP CATS Cable Roll1211 (6) a2 UTP CAT6 Cable Roll1211 (7) Fiber Optic Cable Roll1211 (8) Fiber Connector Set1211 9) Fiber Fussion Splicer Set

1211 ( 10) a1 Patch Cord CATS Set1211/ 10 a2 Patch Cord CAT6 Set1211 10 a3 Fiber Patch Cord Set1211 11 Modular Jack Set1211 12 a1 Wall Plate Single Set1211 (12) a2 Wall Plate 2 port Set1211 12) a3 Wall Plate 3 Dort Set1211 13) a1 Floor Mounted 2 port Set1211 13) a2 Floor Mounted 3 port Set1211 (14) Network Equipment Set1211 (15) Network Cabling LumD Sum

CCTV S stemIP - Fixed Dome CameraIP - Pinhole T e CameraMovable CameraWeather Proof CameraData Video RecorderNetwork Video RecorderCentralized Power Su I with UPSLCD LED MonitorCCTV ConsoleServer CCTVR659 Coaxial Cable

Page 85

Lum SumSetSetSetSetSetSetSetSetSetUnit

Meter

VOLUME III

Page 147: Standardized Pay Items of Works for Civil Works Construction for

Groundin S stemExothermic Weld ConnectorCadweld connectorAir TerminalMD BCW

Nurse Call S stemArea Control UnitNurse Call ConsoleBed StationCorridor Li ht

Page 86

Lum SumPiecePieceSet

Meter

VOLUME III

Page 148: Standardized Pay Items of Works for Civil Works Construction for

,-

1300 al Timber Pile Untreated Linear Meter1300 a2 Timber Pile Untreated Linear Meter1300 a3 Timber Pile Untreated Linear Meter1300 bl Timber Pile Treated Linear Meter1300 b2 Timber Pile Treated Linear Meter1300 b3 Timber Pile Treated Linear Meter1300 al Steel Pi e Linear Meter1300 a2 Steel Pi e Linear Meter1300 a3 Steel Pi e Linear Meter1300 al Steel Pile Tubular Linear Meter1300 a2 Steel Pile Tubular Linear Meter1300 a3 Steel Pile Tubular Linear Meter1300 4 al Concrete Piles Linear Meter1300 4 a2 Concrete Piles Linear Meter1300 4 a3 Concrete Piles Linear Meter1300 4 bl Concrete Piles Prestressed Linear Meter1300 4 b2 Concrete Piles Prestressed Linear Meter1300 4 b3 Concrete Piles Prestressed Linear Meter

TimberTimberTest PileTest PileTest Pile

Page 87

3\11UntreatedTreated

SteelConcreteTubular

with Accessorieswith Accessorieswith Accessories

Linear MeterLinear MeterLinear MeterLinear MeterLinear Meter

VOL III

Page 149: Standardized Pay Items of Works for Civil Works Construction for

1400 1 d Bollard with Accessories Set1400 2 a Cleat Replacement Each1400 2 b Post Replacement Each1400 2 c Bitt Replacement Each1400 2 d Bollard Replacement Each

1402 1 a Pile Cluster 3 Set1402 1 b Pile Cluster 4 Set1402 1 c Pile Cluster 5 Set1402 1 d Pile Cluster 7 Set1402 1 e Pile Cluster 9 Set1402 1 f Pile Cluster 12 Set1402 2 Concrete Dol hin Set1402 3 Tubular Steel Dol hin Set

Page 88 VOL III

Page 150: Standardized Pay Items of Works for Civil Works Construction for

Page 89 VOL III

Page 151: Standardized Pay Items of Works for Civil Works Construction for

Unsuitable ExcavationSur Ius Common ExcavationSur Ius RockSur Ius Unclassified Excavation

Page 90

Cubic MeterCubic MeterCubic MeterCubic Meter

VOL III

Page 152: Standardized Pay Items of Works for Civil Works Construction for

OverhaulOverhaul of Borrow Case 1

~I1702 Structure Excavation Common Soil Cubic Meter1702 Structure Excavation Soft Rock Cubic Meter

1702 Structure Excavation Hard Rock Cubic Meter

1702 Brid e Excavation Common Soil Cubic Meter1702 Brid e Excavation Soft Rock Cubic Meter

1702 c Brid e Excavation Hard Rock Cubic Meter1702 Foundation Fill Cubic Meter1702 Excavation ordered below Plan elevation Cubic Meter

1702 a Shorin cribbin and related works Shorin Lum sum

1702 (5) b Shoring, cribbing and related works Cribbing/Cofferdamming Lump sum

1702 6 a Pi e culverts and drain excavation Common Soil Cubic Meter1702 6 b Pi e culverts and drain excavation Soft Rock Cubic Meter1702 6 c Pi e culverts and drain excavation Hard Rock Cubic Meter

Page 91 VOL III

Page 153: Standardized Pay Items of Works for Civil Works Construction for

1712 (1)

1712 (2)

Bed Course Granular Material

Concrete

Page 92

Class AClass BClass CClass 0Class AClass BClass CClass 0

Slope Protection

Cubic MeterCubic MeterCubic MeterCubic MeterCubic MeterCubic MeterCubic MeterCubic MeterCubic Meter

Cubic meter in-place

Cubic meter in-place

VOL III

Page 154: Standardized Pay Items of Works for Civil Works Construction for

~. ,1716(1) Untreated Timber Piles. furnished Meter1716 2 Treated Timber Piles. Dreservative. furnished Meter1716 3 Steel H-Piles furnished Meter1716 4 a Precast Concrete Piles furnished 400x400 mm Meter1716 4 b Precast Concrete Piles. furnished 450x450 mm Meter1716 5 a Precast Prestresssed Concrete Piles, furnished 400x400 mm Meter1716 5 b Precast Prestresssed Concrete Piles. furnished 450x450 mm Meter1716 6 Structural Steel Sheet Piles, furnished Meter1716 7 Precast Concrete Sheet Piles furnished Meter1716(1h Untreated Timber Piles. driven Meter1716(9) Treated Timber Piles. driven Meter1716 (10) Steel H-Piles driven Meter1716 11) Steel PiDes Piles Meter1716 12 Structural Steel Sheet Piles. driven Meter1716 13 Precast Concrete Sheet Piles driven Meter1716 14 Precast Concrete Piles. driven Meter1716 15 Precast Prestresssed Concrete Piles driven Meter1716 16 Test Piles furnished and driven Meter1716 17 a Concrete Piles cast in Drilled Holes 0.80 Meter1716 17 b Concrete Piles cast in Drilled Holes 1.00 Meter1716 17 c Concrete Piles cast in Drilled Holes 1.20 Meter1716 17 d Concrete Piles cast in Drilled Holes 1.50 Meter1716(17) e Concrete Piles cast in Drilled Holes 1.80 Meter1716 (17) f Concrete Piles cast in Drilled Holes 2.00 Meter

Page 93 VOLUME III

Page 155: Standardized Pay Items of Works for Civil Works Construction for

1716 17 0 Concrete Piles cast in Drilled Holes 2.50 Meter1716 17 h Concrete Piles cast in Drilled Holes 2.80 Meter1716 17 i Concrete Piles cast in Drilled Holes 3.00 Meter1716 18 Concrete Piles cast in Steel Shells 400-500 mm dia. Meter1716 (19 Concrete Piles cast in Steel Pipes 400-500 mm dia. Meter I

1716 (20 Pile Shoes Each1716 21 Splices Each I1716 22 Load Tests

"Each

1716 23 a Bored Piles 0.80 Meter1716 23 b Bored Piles 1.00 Meter1716 23 c Bored Piles 1.20 Meter1716 23 d Bored Piles 1.50 Meter1716 23 e Bored Piles 1.80 Meter1716 23 f Bored Piles 2.00 Meter1716(23 0 Bored Piles 2.50 Meter1716 (23) h Bored Piles 2.80 Meter1716 (23) i Bored Piles 3.00 Meter1716(24 a Permanent Casino 0.80 Meter1716 24 b Permanent Casino 1.00 Meter1716 24 c Permanent Casino 1.20 Meter1716 24 d Permanent Casino 1.50 Meter1716 24 e Permanent Casino 1.80 Meter1716 24 f Permanent Casino 2.00 Meter1716 24 0 Permanent Casino 2.50 Meter1716 24) h Permanent Casino 2.80 Meter1716 24 i Permanent Casino 3.00 Meter1716 25 Permanent Casina Kilooram1716 26 SDlicino of R.C. Piles with Epoxy Each1716 27 a Pile Intearitv Testino Crosshole-Sonic Each1716 27 b Pile Inteoritv Testino Low Strain Each1716 28 Hiah Strain Dvnamic Testino (P.D.A) Each1716 29 a Paintino Works Concrete Structures S~uare Meter1716 29 b Paintino Works Steel Structures Steel Structures Souare Meter

(i:~I~iJiir::.. z z Z ,. '"

'~;:A'CS;1717 1 ... Sheet Piles Timber Linear Meter1717 (2) a Sheet Piles Steel SloDe Protection Linear Meter1717 (2) b Sheet Piles Steel Cofferdammino Linear Meter1717(3) a Sheet Piles Concrete Furnished Linear Meter1717 (3) b Sheet Piles Concrete Driven Linear Meter1717 (3) c Sheet Piles Concrete Furnished and Driven Linear Meter

Page 94 VOLUME III

Page 156: Standardized Pay Items of Works for Civil Works Construction for

UnderdrainBlind drainGranular backfill filter material for underdrains

limBII,IIIII."···· ·\I'~'iiC, .

1720 1 a Manholes 610 mm dia. Each1720 1 b Manholes 760 mm dia. Each

1720 1 c Manholes 910 mm dia. Each

1720 1 d Manholes 1070 mm dia. Each

1720 1 . e Manholes 1220 mm dia. Each

1720 1 f Manholes 1520 mm dia. Each

1720 2 a Inlets tvDe 610 mm dia. Each

1720 2 b Inlets tvoe 760 mm dia. Each

1720 2 c Inlets tvee 910 mm dia. Each

1720 2 d Inlets tvDe 1070 mm dia. Each

1720 2 e Inlets tvoe 1220 mm dia. Each

1720 2 f Inlets tvee 1520 mm dia. Each

1720 3 a Catch basins 610 mm dia. Each

1720 3 b Catch basins 760 mm dia. Each

1720 3 c Catch basins 910 mm dia. Each

1720 3 d Catch basins 1070 mm dia. Each

1720 3 e Catch basins 1220 mm dia. Each

1720 3 f Catch basins 1520 mm dia. Each

1720 4 a Concrete covers 610 mm dia. Each

1720 4 b Concrete covers 760 mm dia. Each

1720 4 c Concrete covers 910 mm dia. Each

1720 4 d Concrete covers 1070 mm dia. Each

1720 4 e Concrete covers 1220 mm dia. Each

1720 4 f Concrete covers 1520 mm dia .. Each

Page 95 VOL III

Page 157: Standardized Pay Items of Works for Civil Works Construction for

r------'---~-~',-------- Metarframes andQratTnqs~tYpe-'---"'- . ,.~'"'_._--- --1720 5) Pair1720 6) Metal frames and covers Pair1720 7) AdiustinQ manholes Each1720 9) Adjusting catch basin Each

Linear MeterLinear MeterLinear Meter

Each

CONCURREDBY:

Director ALTERR. OCAMPO~re u of Construction _.. D

Director MBureau of

~

.MALIGd Safety

Page 96 VOL III