103
STANDARD DETAIL AND SPECIFICATIONS MANUAL September 1, 2008

STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

STANDARD DETAIL AND SPECIFICATIONS MANUAL

September 1, 2008

Page 2: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

SECTION 1.00 DEFINmONS AND ABBREVIATIONS

1.01 DEFINITIONS

1.02 ABBREVIATIONS

SECTION 2.00 GENERAL PROVISIONS

2.01 GE�IERAL

2.02 QUALITY OF MATERIALS

2.03 INSPECTIONS

2.04 CLEARING AND GRUBBING

2.05 EARTHWORK

2.06 MAINTENANCE OF TRAFFIC

2.07 CONCRETE

2.08 PERMITS

2.09 ACCEPTANCE PROCEDURES

INDEX

2.10 PLANTING WITHIN TOWN UTILITY EASEME�ITS

2. 11 LICENSE REQUIREMENTS

2.12 RETAINING WALLS

2.13 OSHA STAI\JDARDS

2.14 SAFETY AND HEALTH HAZARDS

SECTION 3.00 STREETS

3.01 GENERAL

3.02 DESIGN

3.03 SIGHT DISTANCE

3.04 MATERIALS

3.05 CONSTRUCTION AND INSPECTION

3.06 FIRE LANES

3.07 TRAFFIC CONTROL AND STREET NAME SIGNS

3.08 TRAFFIC CONTROL DEVICES

SECTION 4.00 SOIL EROSION AND SEDIMENTATION CONTROL

4.01 SCHEDULING

4.02 TEMPORARY MEASURES

4.03 PERMANENT MEASURES

4.04 COMPUTATIONS

4.05 CONSTRUCTION SEQUENCE

SECTION 5.00 PIPE TRENCHES

5.01 EXCAVATION AND PREPARATION OF PIPE

TRENCHES

5.02 PIPE LAYING AND BACKFILLING

5.03 BORING AND JACKING

SECTION 6.00 WATER DISTRIBUTION

6.01 WATER DISTRIBUTION PIPE

6.02 FIRE HYDRANTS

6.03 VALVES AND APPURTENANCES

6.04 WATER SERVICE TAPS

SMITHFIELD� HORTH CAROLIRA �

STANDARD DETAIL AND

SPECIFICATIONS MANUAL

INDEX

Drawing INDEL1

Date 2/1/2000

I

~

~

swensman
Cross-Out
Page 3: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

6.05 RELATION OF WATER MAINS TO SANITARY AND

STORM SEWERS

6.06 BACKFLOW PREVENTION

6.07 AUTOMATIC FIRE SPRINKLER SYSTEM STANDARD

6.08 TESTING AND INSPECTION

6.09 FIRE PROTECTION DURING CONSTRUCTION

6. 10 IRRIGATION SYSTEMS

6.11 REPAIR OF WATER LINES

SECTION 7.00 SANITARY SEWER

7.01 GRAVITY SEWER MAINS

7.02 !='ORCE SEWER MAINS

7.03 MANHOLES

7.04 SERVICE CONNECTIONS

7.05 TESTING AND INSPECTION

7.06 REPAIR OF SANITARY SEWER Ul\lES

7.07 WASTEWATER PUMP STATIONS

SECTION 8.00 STORM DRAINAGE

8.01 STORM DRAINAGE MATERIALS

8.02 STORM SEWERS

8.03 STORMWATER IMPOUNDMENTS

SECTION 9.00 AS-BUILT DRAWING REQUIREMENTS

9.01 SlTE DATA

9.02 GENERAL INFORMATION

9.03 STREETS

9.04 STORM DRAINAGE

9.05 WATER SYSTEM

9.06 SANITARY SEWER SYSTEM

SMITHFIELD � NORTH CAROLIRA �

STANDARD DETAIL AND

SPECIFICATIONS MANUAL

INDEX

Drawing INDEX_2

Date 2/1/2000

swensman
Cross-Out
swensman
Cross-Out
swensman
Cross-Out
Page 4: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

DETAIL DRAWING INDEX

SECTION 1.00 DEFINITIONS AND ABBREVIATIONS

SECTION 2.00 GENERAL PROVISIONS

SECTION 3.00 STREETS

STANDARD STREET SECTIONS STANDARD STREET SECTlONS STANDARD STREET SECTIONS INTERLOCKED CONCRETE PAVER STREC:T SECTION STANDARD SECTION WITHOUT CURB & GU"TTER STANDARD SHOULDER SECTION WITHOUT SIDEWALK STANDARD STREET CROSS SECTION CUL-DE-SAC DIMENSIONS END ISLANDS FOR PARKING LOTS A.B.C. UNDER 2' 6" CURB & GUTTER STANDARD CONCRETE CURB & GUTTER STANDARD METHOD OF REMOVING EXISTING CURB STANDARD METHOD OF ENDING CURB AND GUT7ER STANDARD CURB AND DRAIN STANDARD DRIVEWAY APRON STANDARD CONCRETE SIDEWALK STANDARD WHEELCHAIR RA~P STANDARD WHEELCHAIR RAMP STANDARD PAVEMENT WIDENING TAPER AND MARKINGS TEMPORARY BARRICADE FOR DEAD END ROADS PRECAST CONCRETE PEDESTRiAN/B CYC .. E UNDERPASS INTERSECTION SIGHT DISTANCE STOP SIGN COWROL SIGHT DISTANCE YIELD SIGN CONTROLLED INTERSECTIONS

SECTION 4.00 SOIL EROSION AND SEDIMENTATION CONTROL

STANDARD TEMPORARY SILT FENCE STANDARD RISER-BARREL SEDIMENT BASIN GRAVEL & RIP RAP FILTER BASIN GRAVEL & RIP RAP FILTER BASIN GRAVEL & RIP RAP FILTER BERM BASIN CATCH BASIN RISER/FILTER CHECK DAM CONSTRUCTION ENTRANCE RESIDENTIAL CONSTRUCTION ENTRANCE DIVERSION DITCH RIP RAP LINED CHANNELS TEMPORARY STREAM CROSSING TEMPORARY STREAM CROSSII\JG OPTION PIPE INLET PROTECTION (PLYWOOD AND STOJ\IE) BLOCK AND GRAVEL DROP INLET PROTECTION STANDARD CATCH BASIN/YARD INLET PROTECTION SHOULDERS, SIDE DITCHES, SLOPES SHOULDERS, SIDE DITCHES, SLOPES

301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316

3170 317b 318 319 320 321 322

401 402

4030 403b 404 405 406 407 408 409 410

411 o 411b

412 413 414

TABLE 4.1 TABLE 4.2

SMITHFIELD ~ KORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

DETAIL DRAWING INDEX

Drawing DDINDEX_ 1

Date 2/1/2000

Page 5: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

SECllON 5.00 PIPE TRENCHES

STANDARD TRENCH & PAVEMENT REPAIR SECTIONS CARRIER PIPE CARRIER PIPE UNDER RAILROAD

SECTION 6.00 WATER DISTRIBUTION

STANDARD 3/ 4" AND 1" METER BOX INSTALLATION STANDARD 1 1/2" & 2" METER INSTALLATiON AND VAULT STANDARD 3" AND 4" METER INSTALLATION AND VAULT STANDARD BLOW-OFF ASSEMBLY STANDARD VALVE RODDING STANDARD HYDRANT INSTALLATION STANDARD HYDRANT LOCATION STANDARD HYDRANT LOCATION (FOR PARKING LOT) STANDARD VALVE BOX INSTALLATION STANDARD CAPPING DETAIL STANDARD THRUST COLLAR INSTALLATION STANDARD COMBINATION AIR VALVE MANHOLE FOR WATER .. . STANDARD COMBINATION AIR VALVE MANHOLE FOR WATER .. . STANDARD REACTION BLOCKING STAI\JDARD MULTIPLE BRANCH SERVICES YARD HYDRANT (NON BUTTERFLY VALVE WiTH 4' MANHOLE AROUND ACTUATOR

SECTION 7.00 SANITARY SEWER

501 502 503

601 602 603 604 605 606

6070 607b

608 609 610

611 a 61 1 b

612 613 614 615

STANDARD SANITARY SEWER TAP AND SERVICE 701 STANDARD SANITARY SEWER LATERAL CONNECTIONS 702 STANDARD PRECAST CONCRETE MANHOLE 703 MANHOLE STEPS 704 STANDARD HIGH VELOCITY MANHOLE INVERT 705 STANDARD MANHOLE RING & COVER 7060 STANDARD MANHOLE RII\JG & COVER FOR WATERTIGHT MANHOLE 706b STANDARD MANHOLE RING & COVER ENCASEMENT 707 STANDARD OUTSIDE DROP MANHOLE 708 STANDARD INSIDE DROP MANHOLE 709 STAI\JDARD INSIDE DROP FOR SANITARY SEWER SERVICE 710 STANDARD AIR TEST TABLE 711 COMBINATION SEWAGE AIR VALVE MAr,,,IHOLE 712 STANDARD CONCRETE ENCASEMENT FOR STREAM CROSSING 713 STANDARD AERIAL CROSSING 714 STANDARD TYPICAL. MANHOLE VENT DETAIL 715 BEDDiNG FOR FLEXIB~E & SEM RIGID SAI\JITARY SEWER PIPE 716 FENCE GATE 717

SECTION 8.00 STORM DRAINAGE

STANDARD YARD INLET WITH CONCRETE SLAB STANDARD YARD INLET WITH GRATE AND FRAME CONCRETE BLOCK OR BRICK CATCH BASIN PRECAST CONCRETE CATCH BASIN STANDARD MEDIAN CURB INLET STANDARD MEDIAN CURB INLET STANDARD MEDIAN CURB INLET

801 802

803a 80.3b 8040 804b

805

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

DETAIL DRAWING INDEX

Drawing DDINDEX_2 Date 2/1/2000

swensman
Text Box
swensman
Cross-Out
swensman
Cross-Out
Page 6: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

WET DETENTION BASIN FIGURE 1 WET DETENTION BASIN DESIGN FIGURE 2 DRY DETENTION BASIN DESIGi\J FIGURE 3

SECTION 9.00 AS-BUil T DRAWING REQUIREMENTS

~

SMITHFIELD e '.NORTH CAROLil'A I

STANDARD DETAIL AND Drawing

SPECIFICATIONS MANUAL DDINDEX_3

DETAIL Date

DRAWING INDEX 2/1/2000

Page 7: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

1.01 DEFINITIONS

CONTRACTOR

EASEMENT

ENG!NEER

INSPECTOR

!NVERT

PLANS

RIGHT OF WAY

STANDARD SPC:CIFICATIONS

SLIBGRADE

1.02 ABBREVIATIONS

ASSHTO

A.B.S

A.F.F

ANSI

ASTM

AWWA

F.

ft.

gpd

ID

lbs.

SECTION 1.00 DEFINITIONS AND ABBREVIATIONS

The successful Bidder to whom a contract hos been owcraed and who hos executed the contract documents.

A property right to use or control real property of another.

The Town Engineer of the Town of Smithfield, an assistant. or other representative d~ly authorized by the Town Engineer.

The Construction Inspections Administrator, on assistant, or other representative duly authorized by the Director of the Construction Management Deportment.

The lowest point in the internal cross section of a pipe or other culvert.

The approved plans, profiles, standard deto, s, supplemental plans, and working drawings, which show the location dimensions, and details of the work to be done.

The land area between the bock of curb or edge of pavement and the property boundary and including the area containing the street.

The general term comprising a the directions, provisions, and requirements contained or referred to in this book entitiled "Smithfield Standard Specifications and Detaiis" and in any subsequent revisions or additions to this book.

That portion of the roadbed prepared as o foundation for the pavement structure.

American Association of State Highway and Transportation Officials

Acryionitrile Butodiene Styrene

Above Finish Floor

American Notional Standards Institute

American Society of Testing and Materials

American Water Works Association

Fahrenheit

foot

gallons per day

Internal Diameter

pounds SMITHFIELD~ HORTH CAROLINA ~

STANDARD DETAJL AND SPECIFICATIONS MANUAL

SECTION 1 .00 DEFINITIONS AND ABBREVIATIONS

Drawing SPECL1

Dote 2/1/2000

Page 8: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

MSc..

MUTCD

NCDEH

NCDEHNR

NCDEM

NCDOT

N.E.C.

NFlPA

NYOOT

OD

P.C.

P.E.

PPM

psi

P.T.

PVC

P.V.C.

P.V.T.

Q(max)

Q(min)

RH

RLS

scs

sec.

s.f.

SU

UL

V

VAC

Mean Sea Level

Manual on Uniform Traffic Control Devices

North Carolina Division of Environmental

North Carolina Department of Environment, Health & Natural Resources

North Carolina Division of Environmental Management

North Carolina Deportment of Transportation

Notional Electric Code

Notional Fire Protection Association

~ew York Deportment of Transportation

Ou;:side Diameter

Point of Curvature

Professional Engineer

ports per million

pounds per square inch

Point of Tangency

Polyvinyl Chloride

Point of Curvature on Vertical Curve

Point of Tangency on Vertical Curve

maximum discharge

minimum discharge

Relative Humidity

Registered Land Surveyor

Soil Conservation Service

second

square feet

Single .Jnit Truck (w'1th 20 feet wheelbase and 30 overall length)

Underwriters' Laboratories, Inc.

volts

Voltage Alternating Currrent

END OF SECJlQ.N 1.00

SMITHFIELD HORTH CAROLINA

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 1 .00 DEFINITIONS AND ABBREVIATIONS

Drawing SPEC1_2

Dote 2/1/2000

Page 9: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

2.01 GENERAL

SECTION 2.00 GENERAL PROVISIONS

All construction shall conform to the requirements and dimensions on the construction plans, Town Standard Details, the Code of the Town of Smithfield, or as stated in these specifications. The design of streets, water systems, sanitary sewer systems, storm drainage systems, and grading plans shall be

ned and sealed by a licensed North Carolina Professional Engineer, Registered Land Surveyor, Architect or Landscape Architect in accordance with N. C. General Statute 89.

2.02 QUALITY OF MATERIALS

It is the intent of this specification to provide materials of the highest standard known to the trade and to provide materials free form defects in workmanship and product. ual material not specified may be used provided documentation and samples necessary for the Engineer to determine the acceptability and ISSUE A WRIHEN APPROVAL are provided to him a MINIMUM of 14 DAYS before being brought onto the construction site. Current specifications and/or the latest revision shall apply in all cases where materials are described by these specifications.

2.03 INSPECTIONS

The Contractor shall provide the necessary manpower and equipment required as a part of the inspection process. The presence of the Engineer or Inspector at the work site shall in no way lessen the Contractor's responsibility for conformity with the plans and specifications. Should the Engineer or Inspector accept materia or work that does not conform with plans and specifications, whether from lack of discovery or for any other reason, it shall in no way prevent later rejection or corrections to the unsatisfactory materials or work when discovered. The Contractor shall have no claim for losses suffered due to any necessary removals or repairs resulting from the unsatisfactory work. Any work which has been covered without the Inspector's approval, shall, at the Inspector's request, be uncovered and be made available for inspection at the Contractor's expense. Work performed before or after Town staff's normal work hours or during the weekend or Town Holidays shall comply with the Town Code and shall include only such tasks that do not require observations by an Inspector. If during the process of routine inspection of a project and related infrastructure begin installed under these regulations, it is found that improper or substandard materials or construction methods are being used or if significant deviation from the approved construction plans is detected, the Town reserves the right to assign a utility inspector to the project. The Inspector shall have authority to act on behalf of the Town in checking all construction for compliance with State and Local standards. The Inspector shall also have the authority to halt any work not meeting Town standards and specifications. Once assigned, the Inspector shall perform minimum of three (3) hours of on-site inspections per work day. All costs associated with the Inspector shall be the responsibility of the Owner and shall be billed accordingly by the Town.

2.04 CLEARING AND GRUBBING

The work of clearing and grubbing shall consist of the cutting, removal, and

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 2 GENERAL PROVISIONS

Drawing SPEC2_1

Date 2/1/2000

Page 10: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

satisfactory disposa of all vegetation and all surface debris. Clearing end grL;bbing shall be conducted in o manner to damage to vegetation that is intended to remain growing and also to prevent damage to adjacent property.

2.05 EARTHWORK

Earthwork shall be defined as removal of earth or soft rock from its natural location or as the depositing of such material into the proper fill areas as designated on the plans.

Rock excavation shell be defined, in the opIr,Ion of the Engineer, as all ledge rock or boulders over 0.5 cubic yard that cannot be excavated without blasting.

A written PERMIT FOR BLASTING must be obtained from the Smithfield Fire Department a MINIMUM of 24 hours before any explosive material or blasting agents are transported into the Coroorate Limits of Smithfield.

Fill Material shall be free from construction material, debris, frozen material, organic matter or unstable material.

For the top two feet be:ow finished subgrocie, no fill material shall be used weighing ess than 100 pounas per cubic foot. The top TWO FEET of backfill material shall be free from stones greater than 4 inches.

For all areas under a proposed roadway, the top twelve (12) inches of subbase, and the entire base course sha I be compacted to a density of 100 PERCENT maximum Standard Proctor density as determined by AASHTO method T99. For that portion of fill under roadways and extending at a slope of 1 to 1 beyond the back of curb, compact to a density of No LESS THAN 95 PERCENT of the maximum Standard Proctor dry density as determined by AASHTO method T99. Fill material shall be placed in lifts of 8 inches or less of uncompacted soil.

Other fill material shall be compacted to a density of No LESS THAN 90 PERCENT of the maximum Standard Proctor dry density as determined by AASHTO method T99. Backfill material shall be placed in lifts of 12 inches or less of uncompacted soil.

2.06 MAINTENANCE OF TRAFFIC

A General

When construction occurs in a traffic zone, traffic control devices must be erected, maintained, relocated, and removed in accordance with the p!ans, specifications, NCDOT Supplement to the MUTCD, or MUTCD. This requirement shall apply for all construction occurring on oublic including construction or repairs by utility companies. The MUTCD referred to in this provision the current edition of the Manual on Uniform Traffic Control Devices for Streets and Highways, as prepared by the National Advisory Committee on Uniform Traffic Control Devices, including all standard documents referred to in Section 1 A- 7 of the MUTCD. The current edition shall be the edition current at the time of construction.

Traffic control devices shall include but not be limited to signs, drums, barricades, cones, delineators, flashing arrow panels, temporary guardrail, temporary concrete median barrier, vehicle-mounted temporary impact attenuators, pavement marking, raised reflective pavement markers,

and pilot vehicles.

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 2 GENERAL PROVISIONS

Drawing SPEC2_2

Dote 2/1/2000

Page 11: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

B. Materials

Unless otherwise required, materials used in the fabrication and installation of construction traffic control devices shall be in accordance with the applicable provisions of the MUTCD.

All enclosed lens (Engineers Grade) sheeting required for use on traffic control devices shall have an identification mark on the surface. This mark signifies that the sheeting meets the requirements of Federal ification L-S-300C for Minimum Reflectivity I Sheeting and Tape. The identification mark shall not interfere with the function of the device, but shall be visible both day and under illumination ct night without the use of special devices.

C. Installation and Maintenance

Existing public streets or highways shall be kept open to traffic ct all times by the Contractor unless permission to close the street, or portions thereof, is granted by the Town Engineer. The Town of Smithfield Police Deoartment must be contacted BY THE CONTRACTOR A MINIMUM OF 24 HOURS before any streets ore closed or partially closed.

Work on any project shall not start until all traffic control devices required for the particular work activity ore properly installed.

Traffic control devices shall be proper:y maintained, relocated os necessary, cleaned and operated during the time they are ir: use. During periods when use of the devices is not warranted, they shall be removed from the work area, covered, or otherwise positioned so that they do not convey their message to the traveling public. The location, legends, sheeting, dimension, number of supports, and horizontal and vertical placement of warning signs, barricades, ar:d other traffic controi devices shall be as required by the plans or the MUTCD.

Weeds, brush, construction materials, equipment, etc. shell not be allowed to obscure any traffic control device in use.

Competent and properly trained, attired and equipped floggers, using "stop" and "slow" paddles shall be provided when two-way traffic cannot be maintained.

The Contractor shall assume fu • responsibility for the continuous and expeditious maintenance or replacement of all construction warning ns, barricades, and other traffic control devices. The Contractor shall continuously review and maintain all traffic control measures to assure that adequate provisions have been mode for the safety of the public and workers. Failure to maintain all traffic control devices in a satisfactory condition shall be cause for suspension of construction operations until proper traffic control is re-established.

2.07 CONCRETE

Concrete shall be only plant-mixed or transit-mixed concrete conforming to ASTM C33 for aggregates and to ASTM C94 for ready-mixed concrete. Any Any concrete poured that has a slump over 4 inches as per ASTM C1

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 2 GENERAL PROVISIONS

Drawing SPEC2_3

Date 2/1/2000

Page 12: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

or has a batched time of more than 90 minutes, will be considered unacceptable. Concrete shall not be deposited on frozen subgrade. Concrete shall not be poured when the air temperature is falling below 40 degrees Fahrenheit, and the predicted low temperature for the succeeding 24 hour is less than 32 degrees Farenheit.

All concrete when placed in the forms shall have a temperature of between 50 and 90 degrees Fahrenheit and shall be maintained at a temperature of not less than 50 degrees Fahrenheit for at least 72 hours for normal concrete and 24 hours for high early strength concrete, or for as much time as is necessary to secure proper rote of curing and designed compressive strength.

Concrete sh al I be air entrained with 5-7 % air. Retarders and accelerators shall be used only as directed by the Engineer.

2.08 PERMITS

During the course of design, and prior to any construction, all permits or approvals shall be obtained from the appropriate Town, State or Federal agencies, as applicable. These shall include but shall not be limited to:

1. Site Plan Approval - Town of Smithfield 2. Subdivision Plot Approval Town of Smithfield 3. Burning Permit Town of Smithfield 4. Sedimentation and Erosion Control NCDEHNR 5. Water System Extension - NCDEH 6. Sewer System Extension - NCDEM 7. NCDOT Encroachment/Driveway Permit NCDOT 8. Wetlands Disturbance US Army Corps of Engineers

2.09 ACCEPTANCE PROCEDURES

All improvements intended for public maintenance are eligible for acceptance by the Town of Smithfield following the procedures outlined below:

After the installation of improvements in accordance with Town Council approved plans and Town Standard Specifications and Details, the Owner /Developer or designee shall contact the Town and schedule a completion (final) inspection.

The Town will accept the improvements or respond with a punch list within 30 days of the request.

The Owner /Developer or designee must complete all items indicated on the punch and any additional items noted, within 60 days or the punch list will be void. The Owner /Developer or designee must then request another completion (final) inspection.

Upon the acceptable completion of all punch list items and payment of any outstanding fees, the Owner /Developer or designee will receive an acceptance letter from the Town of Smithfield. This acceptance begins a warranty for materials and workmanship for not less than one year from the date of acceptance. The warranty will be to the Town from the owner /Developer or designee. The Town will perform routine maintenance during the warranty period.

Upon completion of, or just prior to the end of, the warranty period, the Owner /Developer or designee shall request a final inspection from the Town.

SMITHFIELD NORTH CAROLINA

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 2 GENERAL PROVISIONS

Drawing SPEC2_4

Date 2/1/2000

Page 13: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

The Town will respond with final acceptance or a punch list on workmanship or materials within 30 days of the request.

The owner /Developer or designee must complete all items indicated on the punch list, and any additional items noted within 60 days or the punch list will be void. The Owner/Developer or designee must then request another final inspection.

the acceptable completion of all punch list items, the Owner /Developer or designee will receive a letter of acceptance from the Town. The Town wili begin total maintenance as of the date of the final acceptance letter. Until a letter of final acceptance has been issued, all materials and workmanship ore the responsibility of the Owner/Developer.

Until a letter of final acceptance has been issued, all materials and workmanship are the responsibility of the Owner /Developer.

2.10 PLANTINGS WITHIN TOWN UTILITY EASEMENTS

An "easement" shall mean any area to which the Town has unlimited access for servicing utility lines. Any plantings installed within an easement may be damaged or destroyed during the course of servicing. The Town is not liable for damage to plantings within an easement. The Town will reseed as necessary any bare or disturbed soil for erosion control purposes.

Small and medium shrubs, groundcovers, or grasses may be planted within an easement.

Small trees (under 30 feet in height at maturity) may be planted a mInImum of 10 feet from the centerline of the closest pipeline within the easement or 10 feet from the center of the easement, whichever is greater. Small trees as defined above shall include redbuds, fringe tree, serviceberry, crape myrtle, golden raintree, Hawthorne, hornbeam, saucer or star magnolia, sassafras, smoke tree, sourwood or sumac.

Lorge trees shall not be placed within any Town utility easement.

2.11 LICENSE REQUIREMENTS

All contractors performing any construction activity involving the Town of Smithfield utility system or street system shall be licensed to practice general contracting in the State of North Carolina. The contractor shall be classified in the appropriate area of license for the type construction to be performed and shall not perform construction activity which exceeds the limitations of the designated contractor's license.

2.12 RETAINING WALLS

All retaining walls with a height of five (5) feet or greater must be designed by either an architect or professional engineer and shall be signed and sealed. The design shall be submitted to the Engineering Department for approval prior to construction. All necessary permits (e.g. building permit) must be obtained prior to any construction associated with the retaining wall.

2.13 OSHA STANDARDS

SMITHFIELD NORTH CAROLINA

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 2 GENERAL PROVISIONS

Drawing SPEC2_5

Date 2/1/2000

Page 14: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

All contractors and their employees must comply with all OSHA standards while working on Town projects and while on Town of Smithfield property or rig of way.

2.14 SAFETY AND HEAL TH HAZARDS

The operations of any Town contractor shall not expose Town Smithfield employees to any hazardous chemicals or other occupational safety and Ith hazards. All contractors working on Town projects or on Town of Smithfield

roperty shall inform the project engineer concerning hazardous chemicals which e contractor might using and to which Town employees might become

exposed by working in that area.

The contractor II also advise the Town of the appropriate control measures to be used by the Town employees to prevent exposure and to minimize of exposure.

END OF SECTION 2.00

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 2 GENERAL PROVISIONS

Drawing SPEC2_6

Date 2/1/2000

Page 15: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

3.01 GENERAL

SECTION 3.00 STREETS

The latest revision of the "Standard Specifications for Roads and Structures" of the North Carolina Department of Transportation shall apply unless otherwise specified herein.

Whenever the following terms are used in above said specifications the intended meaning of such terms shall be as follows:

"State" or "Commission" shall be replaced by "Town of Smithfield".

"Resident Engineer" shall be replaced by the words "Town Engineer", in which context it shall mean the duly authorized Engineer, assistant, or representative acting within the scope of the duties assigned or of the authority given by the Town Manager.

"Sampling and testing by Commission" shall be replaced by the words "samp ing and testing by the Town or its authorized testing agent".

"Inspection by Commission" shall be replaced by "Inspection by Town or its duly authorized representative".

3.02 DESIGN

All streets (private and public) shall be designed and constructed to Town of Smithfield Standard Specifications and Details unless NCDOT Standard Specifications are applicable. NCDOT standards shall be used on all existing state roads, extensions of existing state roads, or roads to be maintained by NCDOT.

A. Street Classnications for Street SpecHicationa

Superhighway

Major Arterial

Minor Arterial

Major thoroughfares consisting of interstates, freeways, expressways or parkway links that are characterized by limited access control.

A major street in the city's street system that serves as an avenue for the circulation of traffic into, out, or around the city and carries high volumes of traffic. It is designed to carry more than twelve thousand (12,000) but less than twenty-four thousand (24,000) trips per day.

A major street in the city's street system that serves as an avenue for the circulation of traffic into, out or around the city and carries high volumes of traffic. It is designed to carry more than five thousand (5,000) but less than twelve thousand (12,000) trips per day.

SMITHFIELD ~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_1

Date 2/1/00

Page 16: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

Collector

Subcollector

Local Road

Minor Street

Alley

A street whose principle function is to carry traffic between minor, loco! and subcollector streets and arterio streets but that may also provice direct access to abutting properties. It is designed to carry more tnan two thousand (2,000) but less than five thousand (5,000) trips per day. Typically, a collector is able to serve, directly or indirectly, between two hundred and fifty (250) and five hundred (500) dwelling units.

A street whose principle functions are both the carry traffic between minor and local streets and collectors, or to join two collectors, or a collector and an arterial, and to serve abutting properties. it is designed to carry more than five hundred (500) but less than two thousand five hundred (2,500) trips per day. Typically, o subcollector is able to serve, directly or indirectly, between fifty (50) and two hundred fifty (250) dweliing units.

A street whose sole function 1s to provide access to abutting properties. It is designed to carry more than one hundred fifty ( 150) but less than five hundred (500) trips per day. Typically, a local rood is able to serve, directly or indirectly, between fifteen (15) or fifty (50) dwelling units.

A street whose sole function is to provide access to abutting properties. It is designed to carry one hundred fifty (150) or less trips per day. Typically, a minor street serves fifteen (15) or fewer dwelling units.

A strip of land, owned publicly or privately, set aside primarily for vehicular service access to the back or side of properties otherwise abutting 0'1 a street. Alleys shall be permitted and constructed where deemed necessary by the town in relation to the type of development proposed and shall meet the following requirements:

a. R:ght-of-way 20 feet

b. Minimum centerline radius when a deflection angle of more than 10 degrees occurs 35 feet

c. Property line radius at alley intersections 15 feet

d. Dead-end alleys shall be provided with a turnaround in accordance with Town Standards.

e. No al 1ey shall have access from a major street or highway, but shall hove access points confined to minor streets whenever practicable.

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_2

Date 2/1/00

Page 17: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

Design Aspe_ct~--~M=in~o_r __ ~L=o_c_a_l_~S~u~n-_C_o_l_le~c~to~r~C_o~ll~e_c~to~r-~A=r~te=r~ia=l __ __;S=u=pe::..=r-'-'h=ig..,_h=w=a=y

R/W with C/G 150

50 50 60 70 100

Pavement Width 27 27 34 37 49 N/A with C/G

Pavement Width N/A N/A N/A N/A N/A 60 With C & G

Sidewalks

Design Speeds

Slope or Grade

No

20

10

No

25

10

1 side

35

8

1 side

35

8

2 siaes

45

8

N/A

55

8

Notes: Slopes are maximum slope in percent change in elevation. Yes means required; No means not required; N/A means not allowed. Pavement widths on curb and gutter sections are from back to back of curb. Curb and gutter shall be required on all streets except where specifically authorized otherwise by the Town Council.

B. Horizontal Street Design

All streets shall conform to the mutually adopted Smithfield-Selma-Pine Level Thoroughfare Plan when applicable or shall be designed and located in proper relation to existing streets and environment. Collector streets and arterials shall be as directional as possible but consistent with topography and preserving developed properties and community values.

Residential streets shall be designed to discourage high speed traffic and minimize excessive cuts, excessive fills and cut through traffic.

A minimum tangent of 150 feet is required between reverse curves for major streets, highways, and collector streets. This tangent shall be extended as necessary to provide the minimum runoff lengths for the curves superelevation per MSHT0 gu'idelines. A 100 foot minimum tangent distance will be required between reverse curves for all minor streets. The minimum tangent length of an approaching intersection should be thirty (30) feet for residential streets. All intersections of streets classified as collector or greater shall have a tangent section not less than 100 feet approaching the intersection.

Compound horizontal curves with the same direction of curvature shall have the radius of the flatter circular arc no more than one and one half times the radius of the sharper circular arc. Streets shall intersect each other at right angles whenever possible. The minimum desirable intersection

SMITHFIELD~ NORTH CAROLINA ~

ST MTJ>ARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_3

Date 2/1/00

Page 18: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

angle is eighty (80) degrees. At no time shall a street intersect any other street at less than sixty (60) degrees.

Intersections with a major street or highway shall be at least 800 feet apart. There shall be a minimum of 200 feet between centerlines of street jogs on collectors and major streets. All other access streets shall not be offset less than 150 from their centerline.

Superelevation is to be used on all arterials and collectors. Superelevation shall conform to I\JCDOT and AASHTO standards for superelevation design.

Tapers shall be used as necessary in street design. Approach tapers are used to shift lanes laterally. The following equations shal1 be used as applicable:

L = L L = s w =

WS for posted speeds of 45 WS(sq) for posted speeds of Length in feet Speed in miles per hour Lateral offsets in feet.

mph and greater; 45 mph or less; 60

Turn bay tapers shall be at least 15: 1 for posted speeds of 45 miles per hour and more. The minimum turn bay taper allowed is 8:1. Symmetrical reverse curve tapers are recommended for non-arterial streets. Storage lengths for the turn bays shall calculated using an acceptable method.

Streets with medians shall be designated to allow for proper turning movements for a SU (single unit truck) design vehicle. AASHTO guidelines should be followed for the actual median design and median opening dimension.

C. Vertical Design

Street grades shall be established with respect to existing topography to avoid excessive grading and the removal of existing trees and vegetation whenever practical.

The minimum grade allowed on any street shall be one-half of one percent. (1/2%).

The maximum grade allowed when approaching an intersection is five percent (5%) for the last 100 feet of pavement before the intersection.

D. Geometrics

Radii

A minimum radius of 25 feet to the back of curb shall be required where residential streets intersect.

A minimum radius of 30 feet measured to the back of curb shall be required where a residential street intersects with a non residential street.

SMITHFIE Ll> ~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_4

Date 2/1/00

Page 19: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

It is recommended that the designer consider larger radii or 3-centered compound curves where needed to provide for turning movements of larger vehicles.

A minimum radius of 40 feet will be required where collectors intersect thoroughfare streets.

Cul-de-sacs

Cul-de-sac dimensions shall be as shown in Town of Smithfield Standard Detail 3.08.

A cul-de-sac radius shall be a minimum of 40 feet. The standard maximum length for a cul-de sac shall be 500 feet. The length may be modified depending upon the density within the subdivision. The modification must be approved by the Town Council upon recommendation by the Town Engineer and public safety officials. The recommendation shall consider the development density, land configuration, as well as all safety concerns. The length of a cul-de-sac shall be measured from the last point of alternate access within the subdivision. No median shall be allowed in a 40 foot radius cul-de-sac. A median may be permitted where the cul-de-sac radius is increased and it can be demonstrated that all emergency vehicles can be readily accommodated.

Driveways (Non-residential)

Standard concrete driveway aprons as shown in Standard Detail 3.15 shall be used when the ADT for the driveway is less than 500 vehicles.

Street type turnouts shall be used when the driveway ADT is greater than 500 vehicles or when access by larger trucks must be accommodated. A minimum radius of 25 feet shall be used on all street type turnouts. Street type driveways shall have a minimum width travel lane of 22 feet. Any curb and gutter used will be in addition to the 22 foot minimum width.

Non residential driveways that are unpaved shall have a minimum 20 foot paved surface strip measured from the back of the driveway apron.

Driveways without is 1ands shall be a minimum of 24 feet wide for two way operation. Non-residential driveways with islands shall have a 16 foot entrance lane. A 16 foot exit lane shall be required when one exit lane is used, and a 24 foot exit shall be used for 2 exit lanes.

The number of street and driveway connections permitted serving a single property frontage or commercial development shall be the minimum deemed necessary by the Town for reasonable service to the property without undue impairment of safety, convenience, and utility of the roadway. Normally, not more than two driveways shall be permitted for any single property frontage.

The arrangement of driveways should be related to adjacent driveways and nearby street intersections. Driveways close to street intersections shall be

SMITHFIELD ~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_5

Date 2/1/00

Page 20: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

at least 25 feet from the point of tangency of the radius curvature of the intersecting street. All driveways serving high volume generators shall be located a minimum of 200 feet from the intersection of public roads unless otherwise approved by the Town.

Where two driveways are proposed along a single property frontage to facilitate operations, the minimum recommended distance between the centerlines of the drives shall be 100 feet. The minimum distance between the centerlines of driveways into shopping centers and other high volume generators shall be a minimum of 400 feet.

Driveways (Residential)

Residential drives shall be 12 to 14 feet wide and shall conform to Standard Detail 3.15 for concrete driveway aprons.

Residential drives shall be located a minimum of 10 feet from the point of tangency of curb radii of street intersections.

Curb and Gutter

Curb and gutter shall be required on all streets except where specifically authorized otherwise by the Town Council.

Streets designed without curb and gutter must meet all of the following requirements and be approved by the Town Council:

a. 50 foot right of way; b. 5% maximum vertical grade and 0.5% m1n1mum grade; c. Adequate swale system to carry the 10 year storm in a non-erosive manner; d. Driveways across swales shall be constructed to provide for the passage of the 10 year storm; e. All driveway pipes shall have flared end sections or headwalls on inlet and outlet ends of the pipe, unless otherwise approved by the Town Engineer.

All median curb shall be standard 1 '6" mountable curb as shown in Standard Detail 3.11 Curb and gutter within parking lots may be 1 '6", 2'0", or 2'6" standard curb and gutter. All other curb and gutter shall be a minimum of 2'0" curb and gutter. Where curb and gutter is used on a street section 35 feet and greater, ABC shall be required to extend beyond the curb and gutter in accordance with Standard Detail 3.10. No valley curb shall be used on public streets.

A minimum five (5) foot section of curb and gutter shall remain when removing curb for the installation of a driveway, street turnout or repair of curb and gutter. When less than five (5) feet of the curb remains, the curb shall be removed to the next joint.

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_6

Date 2/1/00

Page 21: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

Parking Lots

Parking lots shall be designed to provide safe maneuverability of vehicles. A minimum parking stall dimension of 9' x 19' shall be provided for 90 degree stalls, 8.5' x 19' for angle stalls, and 9' x 22' for parallel stalls. Handicap parking spaces shall be a minimum dimension of 96 inches with a five (5) foot lane adjacent to the space properly marked with signage in accordance with the N. C. Building Code.

At locations where a sidewalk abuts a 19 foot deep parking bay, the sidewalk shall be a minimum width of six (6) feet. In parking lots where end islands are required Standard Detail 3.09 is recommended.

A minimum pavement structure consisting of 8 inches of ABC and 2 inches of 1-2 shall be used along the travel aisle on parking facilities for multi-family ( excluding duplex and triplex development) and non-residential developments. Access drives for these facilities shall also meet this minimum pavement standard.

All minimum stail depths and module widths shall be measured to the face of curb when curb and gutter is used.

Ali paved parking facilities shall be stripped in accordance with the MUTCD with four ( 4) inch white lines.

Aisle widths for parking lots shall meet the following minimum requirements:

Aisle Width in Feet Parking Angle One-Way Traffic Two-Way Traffic

0-15 degree 16 37 degree 38-57 degree 58-74 degree 75-90 degree

1 1 1 2 13 18 24

24 (0degree only)

24

Sidewalks

Sidewalks shall be constructed within the street right of way in accordance with Town Standards and Town policy. Sidewalks shall be installed at the time of roadway construction or widening unless otherwise approved by the Town Council.

The Town Council may decide some streets which require sidewalk according to the above criteria actually have too little pedestrian traffic to make sidewalk beneficial. In these cases, the requirement for sidewalk may be waived.

All sidewalks shall be constructed in accordance with Standard Detail 3.1 6. The minimum thickness of a sidewalk shall be 4 inches. At locations where a driveway crosses a sidewalk a 6 inch depth is required. Sidewalks

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_7

Date 2/1/00

Page 22: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

shall have a uniform slope toward the roadway of not less than 1 / 4 inch per foot nor greater than 1 /2 inch per foot. The utility strip between the sidewalk and the back of curb shall not be less than 1 / 4 inch per foot nor greater than 1 /2 inch per foot toward the roadway.

Sidewalks shall typically be a minimum distance of five (5) feet off of the back of curb with a minimum width of four (4) feet. This requirement may be varied upon the approval of the Town.

Where sidewalks intersect any section of curb and gutter, a wheelchair ramp in accordance with Standard Detail 3.17 shall be installed.

E. Pavement Design

A pavement design will be necessary for all collector streets and arterials in accordance with these specifications. The pavement design and traffic analysis shall be signed and sealed by a North Carolina Professional Engineer. Pavement design shall be based on subgrade conditions, a 20 year design life and projected traffic loading. Subgrade conditions shall be based upon corrected soaked CBR values at 0.1 inch penetration as per ASTM D 1883. Soil samples used for these CBR tests shall be obtained at intervals not greater than 500 feet. Should a Professional Engineer with expertise in geotechnical engineering certify that the soil in question is of the same type with similar engineering properties this spacing may be increased to a 700 foot maximum spacing. Boring logs and scaled drawings designating boring locations with CBR tests and other pertinent data shall accompany the pavement design.

A pavement design shall also be required for all streets located within areas with Triassic soils. These areas are shown on Figure 3 which includes all areas located west of the line designated as A-A.

The pavement design for areas with Triassic soils shall use the soaked CBR value for the pavement design. Typically, a subdivision will require two (2) to three (3) soil samples as a part of the pavement design. Larger subdivisions, greater than 100 lots, may require additional soil samples at the discretion of the Town Engineer.

All streets maintained by the NCDOT must receive approval of the pavement design from the I\JCDOT prior to the placement of curb and gutter or pavement material.

The pavement thickness shall at no time be less than the design shown in the Standard Detail for the various street widths.

Approved pavement design methods include those as proposed by NCDOT, the 1986 AASHTO Guidelines and the 1981 Asphalt Institute MS 1 document.

The AASHTO method will require use of a terminal serviceability index of 2.0 for collectors and 2.5 for thoroughfares, So = 0.49 for flexible pavement or So = 0.39 for rigid pavements, and a reliability of 98

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_8

Date 2/1/00

Page 23: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

percent for thoroL1ghfares and a reliability of 95 percent for collectors.

Rigid pavement design shall follow either the 1986 MSHTO Method or the Portland Cement Association Method.

F. Pavement Markings

All collectors and arterials shall be marked in accordance with the latest revisions of the MUTCD- unless otherwise approved by the Town Engineer. This shall be noted on roadway and subdivision plans as a requirement of the Developer and shall be done prior to issuance of a Certificate of Occupancy for the development or final acceptance of the roadway by the Town of Smithfield. The pavement markings for all collector streets and thoroughfares shall be thermoplastic. These markings are to be applied in accordance wlth the manufacturer's instructions.

The pavement markings along arterials streets with four (4) or five (5) lanes or which are median divided facilities shall be installed such that the outside lanes are thirteen ( 13) feet in width to accommodate bicycle traffic unless otherwise approved by the Town Engineer.

G. Roadway Widening

All roadway widening shall be in conformance with Standard Detail 3.18.

H. Bridge Design

All public or private bridges shall be designed to withstand HS-20 highway loading unless otherwise approved by the Town Engineer and shall be properly signed and sealed by a North Carolina Professional Engineer.

3.03 SIGHT DISTANCE

Sight distance shaI 1 mean the length of roadway visible to the driver traveling along the roadway or waiting to enter or cross the roadway.

Nothing shall be erected, placed, planted, or allowed to grow between a height of two and one-half feet and ten feet above the level of the center of the adjacent intersection within a triangular area as determined by the chart below in a manner which obstructs the view of motorists using any street or approach to any street intersection so as to constitute a traffic hazard or a condition dangerous to the public safety. The foregoing shall not apply to fire hydrants, public utility poles, street markers, governmental signs, and traffic control devices located within such triangular areas or to signalized intersections with stop/ go phases on all approaches.

The Town shall insure that sight visibility adjacent to Town maintained streets is maintained. The Town will notify the N.C. Department of Transportation of sight distance obstructions located within the right of way of State maintained roadways. The Town shall notify property owners of sight obstructions which exist on private property. The property owner shall be responsible for the removal of the obstruction on their property and shall be solely liable for any and all consequences resulting from their failure to remove the obstruction.

SMITHFIELD ~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_9

Date 2/1/00

Page 24: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

SIGHT VISIBIUTY MATRIX

COI\JTROL DEVICE THROUGH STREET SPEED LIMIT

LESS THAI\J 25 MPH

25-35 MPH 35-45 MPH ABOVE 45 MPH

STOP SIGN 15' X 60' 15' X 70' 15' X 80' 15' X 90'

YIELD SIGN 25' X 60' 25' X 70' 30' x so' 35' X 90'

NOTES: The lesser length is measured along the curb line or pavement edge of the controlled approach; the greater length is measured along the curb line or pavement edge of the through street or non-controlled approach.

A 1 o' X 60' triangle shall be maintained for four way stop intersections on all approaches.

The Town shall review all proposed development plans, including site, subdivision, landscape plans, infrastructure plans and sign plans for compliance with these requirements. All new development within the Town's extraterritorial zoning jurisdiction shall meet these requirements as a part of the plan approval process.

It is recognized that in some cases conditions may exist that prevent the attainment of desirable sight distance due to social, economic or environmental consideration. In such cases, the maximum practical sight distance, up to the desirable values, shall be obtained. In addition, where desirable sight distance 1s not attained, additional measures, such as warning signs, reduced speed zones and other traffic controls may be imposed.

3.04 MATERIALS

Portland cement concrete for curb and gutter, driveways, and sidewalks shall have a minimum 28 day compressive strength of 3000 psi, a non-vibrated slump between 2.5 and 4 inches, a minimum cement content of 564 pounds per cubic yards, an air entrainment of 5-7 %, and a maximum water-cement ratio of 0.532.

Joint filler shall be a non-extruding joint material conforming to ASTM C1751.

Concrete Curing Agents shall be free from any impurities which may be detrimental to the concrete and meet Section 926 of NCDOT Standard Specifications for Roads and Structures.

Aggregate for portland cement concrete shall meet the requirements for fine and course aggregate of Section 1014 of the NC DOT Standard Specifications for Roads and Structures.

Portland Cement and admixtures shall meet the requirements of Section 1000 of

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_10

Date 2/1/00

Page 25: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

the NCDOT Standard Specifications for Roads and Structures.

Water for mixing or curing the concrete shall be free from injurious amounts of oil, salt acid, or other products injurious to the finished product.

Aggregate Base Course shall consist of an approved coarse aggregate produced In accordance with the requirements indicated in Section 910 for either Type A, B, or C aggregate as described in the NCDOT Standard Specifications for Roads and Structures.

Bituminous Surface Course, Type 1-1 and 1-2, shall consist of a mixture of coarse and fine aggregates, asphalt cement, and shall meet the requirements in Section 645 of the NCDOT Standard Specifications for Roads and Structures.

Bituminous Concrete Bose Course, Type HB, shall conform to the general, material, and construction specifications as specified in Section 610 and Sectiori 630 of NCDOT Standard Specifications for Roads and Structures.

Bituminous Concrete Binder Course, Type H, shall conform to the general, material, and construction specifications as specified in Section 610 and Section 640 of NCDOT Standard Specifications for Roads and Structures.

Tock Coat shall be asphalt or asphalt cement and shall meet the general, material, and construction specifications as specified in Section 605 of NCDOT Standard Specifications for Roads and Structures.

Concrete Pavement shall meet Section 700 of I\JCDOT Standard Specifications for Roads and Structures.

Concrete Pavers may be used on privately maintained streets in accordance with Standard Detail 3.04. The Town of Smithfield will not maintain decorative type paved street surfaces such as pavers or imprinted designs within public right of way.

Geotextile Fabric may be used to stabilize a roadway, subgrades, slopes, and for other uses as necessary. At least one week prior to using this fabric, a sample and its associated engineering data shall be submitted to the Town Engineer for approval. Areas stabilized with fabric shall be indicated on "as-built" drawings with the manufacturer name and type fabric indicated.

3.05 CONSTRUCTION AND INSPECTION

No construction shal be conducted until the following applicable items hove been obtained: all grading permits, NCDOT Encroachment Contracts, performance bonds, and Town of Smithfield subdivision and/or site pion approval.

A. Streets

No base material shall be placed on a roadway until the storm sewer, subgrade, utilities, and all appurtenances hove been inspected and meet Town of Smithfield Standard Specifications.

SMITHFIELD HORTH CAROLINA

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

G Drawing SPEC3_ 11

Date 2/1/00

Page 26: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

The Inspector may require field density testing of the subgrade soils from a certified soils laboratory. The soils laboratory shall perform sufficient Proctors to evaluate the compaction characteristics of various soils used in the roadbed. The Inspector may also require field density testing of the ABC used and an asphalt mix formula before either is inspected or approved.

The subgrade shall be compacted as described in Section 2.05 Earthwork. Inspection of the subgrade prior to placement of base course, and inspection of the base course prior to placement of asphalt shall be performed by proofrolling and/or field density testing at the direction of the Inspector.

B. Curb and Gutter, Driveways, and Sidewalks

No concrete shall be placed until the forms and subgrades have been approved by the Inspector. The surface of sidewalks shall be finished to grade and cross section with a float, troweled smooth and finished with a broom.

Subgrade shall be excavated to the required depth, and shaped to the proper cross-section. Where tree roots are encountered, they shall be removed to a depth of 1 foot for the full width of the excavation. The subgrade shall be stable and thoroughly compacted.

Forms shall be set and maintained true to the required lines, grades, and dimensions. Forms shall be constructed with material of such strength and rigidity to prevent any appreciable deflection between supports. Straight forms shall be within a tolerance of 1 /2 inch in 10 feet from a true line horizontally or vertically. Forms shall be thoroughly cleaned of all dirt, mortar and foreign material before being used. All inside form surfaces shall be thoroughly coated with commercial quality form oil.

Grooved Contraction Joints shall be cut to a depth equal to at least 1 /3 of the total slab thickness. The joint shall be no less than 1 /8 inch in width and cut at intervals equal to the width of the sidewalk. A 1 /2 inch expansion joint filled with joint filler shall be placed between all rigid objects and placed no farther than 50 feet apart for sidewalks and curb and gutter, extending the full depth of the concrete with top of the filler 1 /2 inch below the finished surface.

3.06 FIRE LANES

Fire Lanes shall be installed and inspected in accordance with the public street requirements of Section 3.05 A and 3.05 8. The general requirement designates that any building located more than 150 feet from a public road or which exceeds 30 feet in height and is set back more than 50 feet from a public road shall have a fire lane.

Fire lanes shall be a minimum width of 20 feet and shall be properly marked and signed to designate the access as a "fire lane" as specified by the Fire Official. The surface of the fire lane shall be paved with a minimum of 8

SMITHFIELD~ HORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_12

Date 2/1/00

Page 27: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

inches of ABC stone and 2 inches of 1-2 asphalt.

All fire lanes shall be marked in accordance with one of the following requirements:

( 1) Continuously pointed yellow striping along the fire lane with "No Parking Fire Lane" printed with minimum eight (8) inch high letters at forty (40) foot intervals or as directed by the Fire Official;

(2) Continuously pointed yellow curb with "!\Jo Parking - Fire Lone" along the fire lane with "No Parking - Fire Lone" printed with minimum eight (8) inch high letters at forty ( 40) foot intervals or as directed by the Fire Official:

(3) The installation of the MUTCD standard sign showing "No Parking -Fire Lane" placed at each end of the fire lane and at fifty (50) foot intervo Is with arrows on the signs or a continuously pointed yellow strip along the designated fire lone.

3.07 TRAFFIC CONTROL AND STREET NAME SIGNS

Traffic Control and Street !\Jome Signs within subdivisions which will be maintained by the Town of Smithfield shall be consistent with the MUTCD.

3.08 TRAFFIC CONTROL DEVICES

The Town will not allow the obstruction of any public street, private street or fire lane unless otherwise stipulated by the Town Council. This requirement is in accordance with the 1992 edition of the North Carolina State Fire Prevention Code. The reference to an "obstruction" shall include parking, speed bumps or any other device which may obstruct the free passage of emergency vehicles.

All traffic control devices must be shown and approved as a port of a site pion prior to installation and must be in conformance with the Town Standard Specifications. The traffic control devices and all related signs and pavement markings shall be maintained by the Owner as a part of the approval of the pion. Traffic control devices shall include rumble strips, raised pavement markers, pavement undulations (speed humps) or speed bumps.

Rumble Strip

An irregular surface established to draw the attention of motorists and alert them of potential hazards or conflicts. The material used as a part of a rumble strip may be cobblestone, stamped concrete, brick or rough surface asphalt.

A rumble strip may not vary more than one (1) inch in height from the pavement elevation of the adjacent travelwoy. All rumble strips must be located outside any public right of way.

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_13

Date

2/1/00

Page 28: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

Raised Pavement Markers

Raised pavement markers may be used to create an irregular surface to draw the attention of motorists and to alert them of potential hazards or conflicts. The markers must be made of a flexible and durable solid material designed to support vehicular traffic. The placement of markers may be staggered in a manner as approved by the Engineering Department.

All raised pavement markers shall have a maximum height of one ( 1) inch above the pavement surface. The minimum size of the marker shall be four ( 4) inches by four ( 4) inches. The markers must be located outside any public right of way. All raised pavement markers shall have cube-corner microprism reflectors visible from either direction of travel.

Pavement Undulation (Speed Hump)

A pavement undulation is a gradual raised pavement surface which extends transversely across the travelway. The surface material for a pavement undulation shall be the same as the adjacent travelway, typically asphalt.

A pavement undulation shall be parabolic with a maximum height of three (3) inches. The pavement shall be tapered to the edge of the pavement or gutter line for the last twelve ( 12) inches along each side. The minimum length of the pavement undulation shall be twelve ( 12) feet.

All pavement undulations shall be clearly marked with pavement markings or warning signs for each direction of travel. The markings shall consist of letters stenciled on the pavement surface in reflective white paint designating "BUMP" with a minimum letter height of five (5) feet. The pavement markings shall be installed for each direction of travel. These markings sha!I be installed a minimum of twenty-five (25) feet from the pavement undulation. Also, the length of the pavement undulation shall have twelve ( 12) inch stripes in the direction of travel in reflective white paint spaced at a distance of six (6) feet on center.

All pavement undulations must be located outside any public right of way and may not be used on any public or private street, access, travelway, etc. designated as a fire lane. Pavement undulations must be located a minimum distance of 500 feet from a signalized intersection. The Town and/or N. C. Department of Transportation may require the removal of any speed undulation which causes traffic to back up onto a public street.

Speed Bump

A speed bump is an abrupt raised area in the pavement surface extending transversely across the travelway. The surface material for a speed bump shall be asphalt or the same material as the travelway.

The maximum height of a speed bump shali be three (3) inches. The minimum width of a speed bump shall be three (3) feet.

SMITHFIELD HORTH CAROLINA

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_14

Date 2/1/00

Page 29: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

All speed bumps shall be clearly marked with pavement markings or warning signs for each direction of travel. The markings shall consist of letters stenciled on the pavement surface in reflective white paint designating "BUMP" with a minimum letter height of five (5) feet The pavement markings shall be installed for each direction of travel. These markings shall be installed a minimum of twenty-five (25) feet from the undulation. Also, the speed bump shall have twelve ( 12) inch stripes in the direction of travel in reflective white paint spaced at a distance of six (6) feet on center.

All speed bumps must be located outside any public right of way and may not be used on any public or private street, access, travelway, etc. designated as a fire lane. Speed bumps must be located a minimum distance of 500 feet from a signalized intersection. The Town and/or N. C. Department of Transportation may require the removal of any speed bump which causes traffic to back up onto a public street.

Pedestrian Crossings

All locations which are designated for pedestrian traffic crossings shall be designated as a crosswalk with pavement marking and signage in accordance with MUTCD.

All pedestrian crossings must be approved by the Town prior to installation.

END OF SECTION 3.00

SMITHFIELD~ NORTH CAROLIRA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 3 STREETS

Drawing SPEC3_15

Date 2/1/00

Page 30: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

[/)

0 ::, (/) a..

(1) 0 () -, :::t:o 0 ::, (/) ti}-:;::-

(1)

::1:.

c:n "Cl C/2 t"J >-3

§~ [;?~ ::ii::::i oi::::i

t3f:l s:t ;...r :.!> ~z ~i::::i

0

' 0 0 :E l,J 3· S-0

q_ R/W

100.0' RIGHT OF WAY

PAVEMENT DES!GN 5.0' 65.0' 1 1 I 2 ROADWAY 2" 8" A.B.C.

100'

65' ROADWAY

R/W 100.0'

RIGHT OF WAY 1

rso· cso· Kr· I Qd

49.0' ROADWAY-

2;1'11 0 a: =:io .... ~~ n::Z:: >~ ~ .... t:tl1 =t-1 t:,

UTILITY S !RIP

PAVEMENT DESIGN

/2" I 2

8" A.B.C. I 5.0'

NOTES: NORMAL CROWN OF 1 / 4" PER FOOT UNLESS OTHERWISE DIRlCT[D BY TOWN ENGINEER.

F'AVlMENT DESIGN AS SHOWN

OTHERWISE BY THE TOWN

100' RIGHT OF WAY

49' ROADWAY SFCTION

q:_

7o.o· I RIGHT OF WAY

45.0' ROADWAY

2·.. . . . . . . -~" ~· ~-~----=

UTIL.IIY STRI 70' RIGHT OF WAY

45' ROADWAY

R/W

SEE DETAIL 3. 10

R/W

Page 31: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

rJj 2:r--2 "dV? 0 a: M..., Po

~ s~ ~ .... ~ii ~~ =~ ~<=; ::l ::c: f; 0 • O!::i n iii~ ti~ >~

[ ~~ ~ .... ~~ l""I~ ~t::i .... =t-1 ~ ~

'- 0 0

0 -. ~ '" 00

~ ~-0 :::J N'°

PAVEMENT DESIGN

2 1/2" I

8" A.8.C.

PAVEMENT DESIGN

2" l-2

8" A.B.C.

R/W

'

UTILITY STRIP

l :).o· I 5.o·

si°oEw11riZ

UTILITY STRIP

R/W

C'L

70.0' R/W

RIGHT OF WAY 37.0'

ROADWAY

• 4 • •

70' RIGHT OF WAY 37' ROADWAY S[CTION

SEE DETAIL 3.1 0

60.0' R/W

RIGHT OF WAY 34.0'

ROADWAY

60' RIGHT OF WAY .34' ROADWAY SECTION

5o.o· I I - I

?" 1-2

8" A.B.C.

I ,.s •.,. RIGHT oc WAY! Rni6JAY .. (? I

~/ r, ' . .. . I u1•11TY ~L-- I ~ oc1A1L .1.10

NOTES:

OTHERWISE

NORMAL CROWN OF 1/4" PER FOOT UNLESS OTHERWISE DIRECTED TOWN ENGINEER

50' RIGHT OF WAY 27' ROADWAY SECTION

Page 32: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

2-1 -..... SLOf'E /"-MAX~ --

\

PAVEMENT DESIGN

1-2

2" TYPE H

8" A.8.C.

~ =-=[2 "'"' 0 ~.., "' ~ ~~ ~ ....

?£16- ~~ =~ nO __, ::c zo_ oo n

3'

10' (,2.5'

24'

1 /"')'' /M.

28' ROADWAY

{1.5'

••

RIGHT

30'

:JI ~II~ zo L.,J w (..) 2

OF WAY

1.5' ?\ •

TYPICAL DIVIDED HIGHWAY SECTION l_.ANDSCAP[ MEDIAN

24' 2.5 \

10'

. 10" J'\' -~ 2:1 ~---• / ~ s~c:xE ---

NOTES: PAVEMENT DESIGN SHALL --· CALCULATED ACCORDING

3.02 [.

AS SECTION

3.11 -MEDIAN CURB

SEE DETAIL :s. 0

28' 3' ROADWAY

::, Ul ~M > w- "''"' "'!I ~ ~~ "' SEE DETAIL 3. 1 0 STONE TYPICAL DIVIDED HIGHWAY SECTION STONE

d > 011-1 ~~ 1-'t,1 ~o 1-1 =t-1 t:, ~

"-. 0 CJ n ...,

o ro 8 ~' "-. rs.., 0 J

0 l,,..: tO

0 0

NOTES: NORMAL CROWN OI- 1 - ---- FOOT UNLESS

BY TOWN ENGINEER.

PER DIRECTED

CONCRETE Ml:.DIAN

b)()TES: PAVEMENT DESIGN SHALL BE AS SHOWN OR AS CALCLJL.ATFD ACCORDING SECTION :S.02 WHICHEVER IS GREATER.

Page 33: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

NOTES:

1, EXISTING "CABC" IN ROADWAY MAY BE USED AS BASE COURSE AFTER COMPACTli\G TO ACHIEVE 100% PROCTOR. LOCALIZED UNDERCUTTING AND REYAIR SHALL BE REQUIRED WHERE PROOFROLLING RESULTS IN PUMPING OR AS DIRECTED BY THE !OWN. TESTING OF SUBGRADE/"CABC" COM?ACTION SHALL BE REQUIRED.

2. EXISTING ROADWAY PAVING SHALL BE SAW-CUT TO RECEIVE PLACEMENT OF GRADE BEAMS. A THREE-DAY CURING PERIOD SHALi_ BE REQUIRED FOR GRADE Br.AMS PRIOR TO REMOVAL OF REMAINING BITUMINOUS PAVING. BASE BELOW GRADE BEAMS SHALL BE COMPACTED TO 100% PROCTOR.

3. BRICK PAVED STREETS SHALL NOT BE MAINTAINED BY THE TOWN OF SMITHFIELD.

('.:)) No. 4 REBAR - CONTINUOUS

EXISTING "I BIT. PAVING--

REPAIR CUT PRIOR TO SETT:NG PAVERS

±3"

--i 00 • r,'I "QOO 0 re

~:i t°"l>-3 Po < ~· ("')~ mm :;:i _:,_.... ~ ..... I SQ~ ~~ =~

±8"

,m >-3 = m o. ..., m 0~ -o ~M ~ UJo oo>-3 "'!I ~~ ~~ Po g:i > c:.,1-1 I :,m ~r>. t-'~

EXISTING "ABC"

>z .... t""l;j • >t-1 \:1 ~

CONCRETE CAST -IN-PLACE GRADE rJ

SECTIONAL VIEW

REL!ff TOOLING ( 1 MAXIMUM TYPICAL)

\ INTERLOCKED PI\V[R SYSTEM

;;:~<,;7r~~ I-3-1 /L,,~~

-----------

1" MAX. STONE SCREl:.NINGS COURSE

EXISTING "CABC" COMPACTED

TO 1 00% PROCTOR

Page 34: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

§§ :r l/1 o~ C 0 ~::i

0. Oo C ' ' 0. CT

V) R' (1)

[)

C) c:: C 0 ;::::J (1)

'

~ i:? ~ (])

r;n '"'Ii r;n t,,J,.;i s~ 8~ ..., Ot::I ~E:l ~~ ~ ~ ~t::I

S;i OD (.,) ~ 0-:, (Jl L()

21: 112 oEC po .... ~~ n:I:: > 11-pJ ~ ..... t::~ i:: t-t t1

50' R/W M!NIMUM

6' SHOULDER M!N.

6"

ASPHALT

1'

1 "/FT -----ABC

NOTES:

THIS SECTION MAY ONLY 8[ USED ALL OF THE

FOLLOWING CONDITIONS ARE M[T

1. STREEl IS WITHIN A WATERSHED PROTECTION DISTRICT.

2. STREET DFSIGNATED TO BE WlTHOUT CURB AND AS PER TOWN COUNCIi. APPROVAi .

3. STR[[T VERTICAL GRAD[ SHALL NOT EXCEED 5% AT ANY POINT.

I\ SWALE SYSTc::M DESIGNED TO CARRY Al LEAST THE 10 YEAR STORM.

5 VELOCITY WITHIN SWAlF BE NON~EROSNE.

6, DI:. TAILED DRAINAGE CALCULATIONS f'IEOUIRED.

2'

2' ROUNDING

~-rv·

u'. -7

Page 35: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

w 0 (l_ L1J

0 0 w 0 z _J u z ::::i

U) X ::::i

0 w 0 -O:'. O:'. I-() L,_ 0 ('.)

_J [Y z N

<( 0 _j 0:: ::::i

_J

I- <(

~ ::::i T z u U)

_J I _J

I-<( I- w T :I; w U) LL

O:'. U) I- l[)

w w n 0 w _J [Y LL ::J I- 0 Q U)

_J z (/j _J 0 I-

<( I-

0 u O:'. 0

z u..l w LL 0 U) '--

<(

z 0 U) w w U) O:'. w Vl 0 ('.) I-::J Cl:'.

w u 0

~ w z OJ <( <(

,...-j / v C 0

0

c_j ,...-j z

0 0::: u w ci SMITHFIELD I- >-

I- z <(

0 ::J 3: n ('.) ci 0

0 I- <( NORTH CAROLINA 0 Vl 0

0:: z 0:: <( <( L u (lJ 0

OJ CL OJ STANDARD DETAIL AND Drawing z <( 0:::

(/) <( SPECIFICATIONS MANUAL 0306 I- ::J 0 (/) u

Date Standard Shouider Sect;on Without Sidewo k 1/11

Page 36: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

R/W OR PL

CLJANOLJT & WATER f/ETERI

t} I I

V1 112 Vlo rJJ ·s g-5- ;:;l~ 0 "'0 (i' Pl' =,·Q_ :;;~ 1-3 .....

'°VJ ,...i:::, 1-31 ~J 8~ = ;:.:~ So n::C

'< o '..!!:H > ,-, rn>-l ~ g g ~~ ,., ou, > t--1 '.:c.U) z 0 gro d~ t-1~ wS;_ >o ....

g· t"' •t-t >'=' ~

-( ~ 0

~ ~ ·, ~ (D

0 0

" (_,j :;;.

ts.) 0::,

0 ..._,ID

0 0

UT~:11Y 6"2'1~ STRIP I

EB TELEPHONE~ CONDUiT

z ~ n

\

WATER__/

1 ,1'

(NORTH & EAST SIDE)

VARIABLE

O'

ROADWAY

z :;s;;

.,_J·

I R/W

VARIABLE

POINT OF CROWN

~SANIIARY

CROSS SECTION

4": 1

SEWER

R/W OR

STRIP 12

·161~1,5,; biot~ALK

j'

J,, CLl:_ANOUT &

/; WATER M I I I

(SOUTH AND WES!

\_ ELECTRIC CONDUIT

NOTES:

MAX. SLOPE

THERE SHALL BE AN 1 VERTICAL SEPARATION BETWEEN WATER AND SEWER LINES

AND/OR SANI BE A MiNIMUM OF

FEET FROM THE EDGE OF AND GUTTER.

Page 37: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

Ul z 0

I f-u f- w

3: UJ Q:'.

C) w z f-

f- ~ u

Cl'.'. w Ul w Q:'. ,· w '-f--- 0 z

1-' -··J _J

z w <( u w ..,.- CY

~ '-U)

z Q:'. z 2

0 2 z

lt) 2 -0 N < I")

II Q:'.

--~----" M/'l:J

/\l z 2 I -LO

N I I I I

z I 2 I ,n

I N

~/ u <( Ul I

c.c 0 I

I _J

::::,

I u

I

\ \

\

"' "--' ---

/

I

r

I I I I I I z

2

I lJ) N y ~

\

/ /

/

M/'d

Ct:

w Ul

:s: Cr'.

2 w I ::::, f-2 0 x

<( 0 2 ~

> f- 0 w Cr'. w 0... LL 0...

0 <(

0 (/) l.O (/)

\ w ....J

\ z ::::,

I

I

I I

SMITHFIELD NORTH CAROLINA

STAl'i'DARD DETAIL AND SPECIFICATIONS MANUAL

Cul-De-Soc Dimensions

Drawing

0308

Dote

Page 38: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

LI.. 0

yaJ uD:'. ~7

T\n-r-

1

1 (

OJ n

j

L 0 y [D uCl'.'. <{ ::J mu

a:: . 0..

Ni:=

N

b (D

SMITHFIELD NORTH CAROLINA

STANDARD DETAIL AND Drawirq SPECIFICATIONS MANUAL 0309

End islands For Dote Darking Lots 1 /1'

Page 39: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

STANDARD 2'- 6" CURB &

( GIITTC,

.. --~~-··--., 4.,

D

- A.8.C. (AVG. DEPTH= 3 1 " OR

D 6 1 /2", WHICHEVER IS

SMITHFIELD NORTH CAROLINA

ST A.c'llfflARD DETAIL AND SPECIFICATIONS MA'.'\TUAL

A.8.C. Jnder 2'-6" Curb & Gutter

Drawing

0310

uate

1/11

Page 40: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

- I

iJI' 7"t ~­~

00 2: 112 -CC/l O a: t,,:1--l

n(/) n> ~ co ;;z ~t-11 ocg ()~ =~ o~ ~ ::.,0 = a. s~ n oii zt,,1 > c::.i rn>-l ~ ~n :;,~ ~ ~ii~ ol-l

en ~i t:~ ~t-1 t, ~

-(_~ Cl

m o ~ (.,-1 -·

:J -" u)

R. 1/21/ ___ KJ~N~ ~L~R Jl · 6" r

A _j NOTE: MAINTAIN 50' MAX. BETWEEN JOINTS

OR AT ALL RIGID OBJECTS

FRONT ELEVATION

TRANSVERSE EXPANSION JOIN.I

COMBINAflON CURB AND GUTTER

NOTES: 1 CONCRETE SHALL BF: 3,000 P.S.I.

2. CONTRACTION JOINTS SHALL BE SPACED AT 1 O'

WILL BE ALLOWED WHEN A MACHINE IS

3. FJNISH ALL CONCRETE WITH CURING COMPOUND

15' SPACING

~ 1 '-6"

I 2· •-- , • •

SECTION A--A SIDE ELEVATION

g" g"

~I l 1 ;3/1\"R

/ . j" i . ,. " -[---;:::-·· 2"~ ·.-~. 7:~ ~ ..

~7

6 3/4" ~- 1· 6" ~-t

MEDIAN CURB AND GUfTER SIDE ELEVATION

R.

Page 41: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

0 C UJ ',--+ 0- 0

::, ,.,... _____ o. 770 0 ..., , Cl

0 ;;;: m

0~ ..., ::, <·O (1) D..

~ 0 '< __,__

~.

00 '"dl:/l M~

§i r'ii:;; ~6 ot:t :zM 00~

~~ ~~ ~t::,

~ 01 0 0 , ,--+ Q (D O:;:

vJ -· ~ 7 f\.) U:)

PORTION TO BE REMOVED

STEP ONE

2: I'll oz ::io .... ~t-i n::I: >~ ~ .... t:~ :!t-1

t1

- GUTTER LINE

A 1 1 DEEP CUT SHALL MADE PERPENDICULAR TO BACK OF CURB AND THEN PARALLEL WITH GUTTl:.R LINE

DEEP SCORE

45· ANGLF BRl:AK ~

PORTION TO BE REMOVED

STEP TWO

CURB AND GUTTER SECTION SHALL Bl REMOVED IN ACCORDANCE WITH DRIVEWAY WIDTH APPROVED BY THE TOWN

PERPEND!CULAR CUT IS WITHIN 12" FROM A JOINT, TH[N THF: PARALLEL CUT SHALL BE MADE TO THAT ,JOINT.

1 -1 " DEEP SCORE

'

Page 42: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

-~----'

SCORE FULL WIDTH OF CURB AND GUTTER

PLAN

2'-0"

FRONT

2'-0"

1' 5" I 6"

I 'CJ 1~·-··-~~ :J · ..

E!\JD

SMITHFIELD NORTH CAROLINA

ST.AJ.'IDARD DETAIL AND SPECIFICATIONS MANUAL

Slondord Method of Ending Curb and Gutter

Drawing 0313

Dote 1/11

Page 43: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

00 =z: 112 -dOO =le ~~ ~ Sis ~..._. ~§ =~ So n::J:: ~~ >11-1!1

cl- ~~ ~ ..... ~~ t: tl1 t"' -= t-1

>t1 ~

THE EDGES DRAIN HOLE MUST BE AND FINISHED SMOOTH AT OF THE CURB

[I'.'.

-"' ,<:$;QI ' II I_______.._____,

; 3" R

'v 'CJ 1'

" NOTES:

7" 'v q

-CURB DRAINS SHALL NOT BE CONSTRUCTED '.:J 'J

If

18" OF CONTRACTION OR EXPANSION JOINTS

-OPENING GRADE MAY VARY BETWEEN A MAXIMUM SLOPE OF 1 FT. AND .A MINIMUM OF 1 PtR

MORE THAN ONE HOLE MAY BE INSTALLED PROVIDED THE HOLES ARE LOCATED WITII 18" MINIMUM SPACING

FT, ~1'-•9" I -1 • ... g"

2'-6"'---_

-IN LIEU OF CUTTING THE CURB TO INSTALL A THREE SEE GENERAL NOTES FOR REQUIRlD SLOPE INCH PIPE, A FOUR INCH CONCRETE BORE MAY USED

Page 44: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

NOTE TO CONTRACTOR: -RESIDENTIAL DRIVEWAY TO BE 12' TO 24' IN WIDTH

-'f- -COMMERCIAL AND INDUSTRIAL DRIVEWAY TO BF: A MAXIMUM OF 36' WIDE · ·ALL CONCRETE. SHALL BE 3000 PSI

EL[V "B" MINUS ELEV "A" EQUALS 1 INCH

DRIVEWAY BY OTHERS SIDEWALK

l_ - - I B --t~l ) ~ _ I' 12• MIN

CONCRETE DRIVEWAY APRON W/ 6" MIN THICKNESS

5.5'

10.6%

1 EXPANSION

r.n :z: II) ~"' o EC

l/) x,.., po g ;i 1-i .....

>~ ~~ ::ct-I vCL ,._, ::c: ' .... g ~§; ~

i~ ~~ ~~ t-'~ Ft::3 ..,.. i::t-1 t:, ~

R i SE ---+--------,.____,.s:-----=:==-.

CONCRETE DRIVEWAY APRON

42" RADIUS L() EXISTING PAVEMENT

EXPANSION JOINTS -------1_,! EXISTING CURB AND GUTTER

PLAN VIEW

1. CURB SHALL BE TAPERED TO FINISH FLUSH WITH SIDEWALK.

2. BEGINNING RADIUS SHALL NOT ENCROACH ON ADJACENT PROPERTIES BASED ON A PROJECTION OF. THE PROPERTY LINE FROM THE RIGHT OF WAY TO THE CURB LINE.

COMPACTED BACKl'II .. L

.3. SIDEWALK SECTION SIIALL NOT BE REQUIRED ALONG Sl REETS WHICH ARE NOT PLANNED FOR SIDEWALK.

DRIVEWAY BY OTHERS W/ MAX. RECOMMENDED GRADF

,____5'_( x 1,~

)(\01°)/ SIDEWALK --

5' 5'

1 EXPANSION

TYPICAL Sl:.CTION

-%"

Page 45: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

0 z :::J 0

0 Q_ L() 2

0 LL u 0

X C)

< z 2 ix <(

:J u

w I OJ f::= 0 3: f-

0 f- w z I 6 <n h••) z z c;::

Q w [/) a:: z <( 0 D... I-X w w

f-w w (.f) Q:'. er: u w z > 0 [/) u z

~I <( er: _J

f- <(

0, N z,

::,: _J <(

~ 5 w 0 uio

~ _J

0 0 oo [/)

l.1.J l"l [/)

[ 0

0 w :]_ f-

0 u <(

Q:'. o_ Q_ ii~ >:

V '/ 0 , u / /

~I J/ / ,:._

0... / /.

c2 ''-f- '.< [/)

'" ~ i::: ;,/' :::J -< E >'. _) <-[/) ______-:,; [/) -<( er:: C)

i 0::: w f-f-

O:::J \ I C) )

N O ~ • 0 z I I Z <( I .. _J

i= CD (/) et: x =:i WU

_j_ ]Nil AVM ..:JO. li-1:Jl:c!

>rllft,\JOIS

dlclS AFllln

0 I

LO OJSS\ic:18

.,O- ,Z 8Nl.!.SIX3

z Q f-u LJ (/)

_ _J

<( u Q_

i'.=

5 L1J

> z < D...

w u <( LL Ct'. :J [/)

:,c _J Ct'. <( w 5 _J

l:.J _J

c;::

~~ f-z f-z 0 -:,

0 -:, z

Q [/)

,.t/l z <( Q_ X w

w (j; Q:'. w >

c:i (/)

z <( <( Cr'. 0::

f-

,.17

SMITHFIELD NORTH CAROLINA

STM"DARD DETAIL AND SPECIFICATIONS MANUAL

Standard Concrete s:dewclk

Date

1/12/2000

Page 46: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

(/)

a ::, 0. 0

:;o ci. 0

3::ai: ,:;,:r

(1) (1)

() :r 0 ::;·

-:::: 0 - s. Na,

"­N 0 0 0

00

§i (")~

g~ 1~ ~i

0

' ao (.,.I ::E ::j s· )> lD

i----- w

UTILl1); STRIP I SIDEWALK ( 4• STD.)

6" 1 I 0.02~MIN ) B CY,RB 0.08 MAX) 0.01 ~MIN.)

GLITTER SHOWN) - -~ ~;::2_,, NOR. ... , ~-=~-,;_--

~---~~,,__---/~~~~7-r-··- BACK OF SIDEWALK DROP*,**

24 CURBS'E. . -~ 0.04 NORM)~ MAX'

- -tt- - SECTION B-B - 12:1 MAX. RAMP ~

ISOMITRIC VIEW

.111 =II :':1-1 mt-I ~e; ~ .... £::~ =:t-1 t:,

(0

2.35" oc

W+A+91 X 5.8' ls.a· 6.B'J_tl 7.8' 7.3 8.8' 17.3 7.8' 7.8

!'U' 8.3 11.4 8.6 ~-7 8.9

~~ 3

.. SEE INSET A

TOP OF CURB SIDEWALK----~ ELEVATION

~A EXPANSION JOINT

--------

oo<i<ooco tinocaoo

IIQ,0,QQC:,,>QOOOCO

7 r- 2.35" oc

11 PLAN SLIP RESISTANT WARNING SURFACE

SECTION RAMP FLOOR DITAIL

INSET A SEE NOTE

B = X-(A+9")

SEE NOTES 2 12 & 17

THIS PORTION OF MUST FALL WITHIN CROSSWALK LIMITS. (SEE NOTE 10)

B = DISTANCE FROM FRONT EDGE OF SIDEWALK TO BACK POINT OF 12: 1

* BACK OF SIDEWALK DROP SIDEWALK SLOPES.

** BACK Of' SIDEWALK DROP REQUIRED FOR SIDEWALK SLOPES 0.04.

SECTION A-A

NOTE:

SEE INSET A ----1'71--' AND NOTE 1

PLAN VIEW

GUTTER

A PORTION OF ONE OR 80TH RAMPS MAY EXTEND OUTSIDE THE RETURN.

EXPANSION JOINT

Page 47: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

VARIABLE RADIUS

VARIABLE RADIUS

SEE NOTE 4

6' MIN.,

VARIABLE RADIUS

w _J

m <{

1Z ~ ='==

VARIABLE RADIUS

SEE NOTE 12

DETAIL SHOWING TYPICAL LOCATION OF WHEELCHAIR RAMPS, PEDESTRIAN CROSSWALKS AND STOP BARS

Ill -~ ~Ill 0 EC

s ?i~ Pl' :, SJ 1-111-1 A)Q (;?~ = 1-4 DCL ~ = :i:::e: 01:1 n -c,::s- zt,,.1 > * Ctl"'3 ~

g: ;~ I'll .... ~- >~ c tt.t

r •t-1 :a,. t:,

~D Do ~ D -, N crj OD " '.:'.! ~- • ~ s.j~ * o rn 0

VARIABLE RADIUS

VAR

VARIABLE RADIUS

PROPOSED SIDEWALK PROPOSED SIDEWALK

'::l :!il 1Z :;

w _J

4' -:-_O" ~ cc

STOP LINE :;

/ PROPOSED SIDEWALK \lfui,_/ ______ _

DETAIL SHOWING TYPICAL LOCATION OF WHEELCHAIR RAMPS, PEDESTRIAN CROSSWALKS AND STOP BARS FOR TEE INTERSECTION

NOTES:

1. THE WALKING SURFACE SHALL BE SLIP RESISTANT. DETECTABLE WARNING DOMES SHALL COVER THE FULL WIDTH AND DEPTH OF THE RAMP FLOOR. THE DETECTABLE WARNINGS SHALL CONSIST OF RAISED TRUNCATED DOMES WITHA DIAMTER OF NOMINAL 0.9". A HEIGHT OF 0.3" AND CENTER-TO CENTER SPACING OF NOMINAL 2.35". THE RAMP MAY BE YELLO WIN COLOR OR ANY COLOR WITH A 70% CONTRAST RATIO.

2. CROSSWALK WIDTHS AND CONFIGURATION VARY: MUST CONFORM TO TRAFFIC DESIGN STANDARDS.

3. NORTH CAROLINA GENERAL STATUE 136-44 44 REQUIRES THAT ALL STREET CURBS BEING CONSTRUCTED OR RECONSTRUCTED FOR MAINTENANCE PROCEDURES, TRAFFICE OPERATIONS, REPAIRES, CORRECTION OF UTILITIES OR ALTERED FOR ANY REASON AFTER SEPTEMBER 1, 1973 SHALL PROVIDE WHEEL CHAIR RAMPS FOR THE PHYSICALLY HANDICAPPED AT ALL INTERESECTIONS WHERE BOTH CURB AND GUTTER AND SIDEWALKS ARE PROVIDED AND AT OTHER POINTS OF PEDESTRIAN FLOW. IN ADDITION SECTION 228 OF THE 1973 FEDERAL AND HIGHWAY SAFETY ACT REQUIRES PROVISION OF CURBRAMPS ON ANY CURB CONSTRUCTION AFTER JULY 1 1976 WHETHER A SIDEWALK IS PROPOSED INITIALLY OR ISPLANNED FOR FUTURE DATETHE AMERICANS WITH DISABILITY ACT (ADA) OF 1990 EXTENDS TO INDIVIDUALS WITH DISABILITIES, COMPREHENSIVE CIVIL RIGHTS PROTECTIONS SIMILAR TO THOSE PROVIDED TO PERSONS ON THE BASIS OFRACE, SEX, NATIONAL ORIGIN AND RELIGION UNDER THE CIVIL RIGHTS ACT OF 1964. THESE CURB RAMPSHAVE BEEN DESIGNED TO COMPLY WITH TITLE 111 OF THE ADA, BECOMING EFFECTIVE ON JANUARY 26, 1992.

4. WHEELCHAIR RAMPS SHALL BE PROVIDED AT LOCATIONS AS SHOWN ON THE PLANS OR AS DIRECTED BY THE ENGINEER. WHEELCHAIR RAMPS SHALL BE LOCATED AS INDICATED IN THESE DETAILS. HOWEVER THE LOCATION MAY BE ADJUSTED BY THE ENGINEER WHERE EXISTING LIGHT POLES, FIRE HYDRANTS, DROP INLETS ETC. AFFECT PLACEMENT. AT ALL LOCATIONS, NOT LESS THAN 2 FEET OF FULL HEIGHT CURB SHALL BE PLACED BETWEEN THE RAMPS.

5. NO SLOPE ON THE WHEELCHAIR RAMP SHALL EXCEED 1"/1' (12:1) IN RELATIONSHIP TO THE GRADE OF THE STREET.

6. IN NO CASE SHALL THE WIDTH OF THE WHEELCHAIR RAMP BE LESS THAN 40" (3'-4"). HOWEVER WIDTH MAY6. IN NO CASE SHALL THE WIDTH OF THE WHEELCHAIR RAMP BE LESS THAN 40" (3'-4"). HOWEVER WIDTH MAYEXCEED 40"

7. US£ CLASS "B" CONCRETE WITH A SIDEWALK FINISH IN ORDER TO OBTAIN A ROUGH NON-SKID TYPE SURFACE. (SEE DETAIL 317A)

8. A 1/2" EXPANSION JOINT WILL BE REQUIRED WHERE THE CONCRETE WHEELCHAIR RAMP JOINS THE CURB.

9. THE INSIDE PEDESTRIAN CROSSWALK LINES SHALL BE SET NO CLOSER IN THE INTERSECTION THAN WOULD BE ESTABLISHED BY BISECTING THE INTERSECTION RADII. (SEE NOTE 14)

10.THE CURB CUT AND THE PEDESTRIAN CROSSWALK LINES SHALL BE COORDINATED SO THAT THE BEGINNING OF THE WHEELCHAIR RAMP WILL FALL WITHIN THE PEDESTRIAN CROSSWALK LINES.

11.THE MINIMUM WIDTH OF THE PEDESTRIAN CROSSWALK SHALL BE 6 FEET. A CROSSWALK WIDTH OF 1 O' OR GREATER IS DESIRABLE.

12.STOP LINES, NORMALLY PERPENDICULAR TO THE LANE LINES, SHALL BE SUED WHERE IT IS IMPORTANT TO INDICATE THE POINT BEHIND WHICH VEHICLES ARE REQUIRED TO STOP IN COMPLIANCEE WITH A TRAFFIC SIGNAL STOP SIGN OR OTHER LEGAL REQUIREMENT. AND UNUSUAL APPROACH SKEW MAY REQUIRE THE PLACEMENT OF THE STOP LINE TO BE PARALLEL TO THE INTERSECTING ROADWAY.

13.PARKING SHALL BE ELIMINATED A MINIMUM OF 20 FEET BACK OF PEDESTRIAN CROSSWALK.

14.ALL PAVEMENT MARKINGS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) PUBLISHED BY THE FEDERAL HIGHWAY ADMINISTRATION AND THE NORTH CAROLINA SUPPLEMENT OT THE MUTCD.

Page 48: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

1-­z

\~ ~ ll

w 0

~I

5'

4'

~,10UND ,~f;%~~1«~~~~ ' ' 1-',W,µ),>J,>)7'" .,,

w Cl 0 w

I ,

LJ

~ IIIJIII ~ 1 DETAIL

o. rn ---a: ro >-cm 0 s· ;2 ~~ '° ,og S@ ~t-1 i~ ~~ =~ (l) Cl -3 ::c: , ""' o~ ot;; n ::; < ~l:"J ..... ... Q.CD rn-3 .,,,,.. .. ...

1f~ ~~ ~ .... ~;:'..- ~~ t-' ... ::; ;i...t;; 1-11 L•..I

'5; t"' •t-1 >t::,

,o O ~ _. S- '

(l) 0 0

(,,; "· -· :J OJ '°

B.

C.

D.

E.

BOTTOM EDGE OF DELINEATOR 4' ABOVE ROADWAY. THE DELINEATOR STRIPES SHALL SLOPE UPWARD AND OUTWARD EROM TRAFFIC. DELINEATORS TO BE SPACED ON AT 1 OF HE D:STANCE D SHOWN BELOW f'OR NEW WIDTHS < 15 FT OR AT 1 / 4 FOR WIDTHS > 15 FT. DELINEATORS SHALL BE MOUNlED ON BREAKAWAY POSTS. DELINEATORS SHALL BE REFLECTORIZED.

~I I :::JI ~ ~I ~1 ~ w ~I Ill 0 0 0:: 0:: ll Q, 1

I ___ _L_ - --

NCDOT ~

W23-1 ~\,_", _ ...... .

1 TAPER ON BOTH ENDS OF ROADWAY WIDENING SHALL BE A MINIMUM 2: 1. THE TOWN ENGINEER

NCOOT RESERVE THE RIGHT TO REQUIRE TAPER IF DEEMED NECESSARY FOR THE

or:- THE PUBLIC,

2 A SOLID WHITE EDGE MARKING SHALL BE EXTENDED ALONG WIDENING AT EXISTING P/WFMENT.

3. DELINEATORS SHALL ONLY REQUIRED AT TAPER FROM CURB TO EXISTING PAVEMENT IN DIRECTION or TRAVEL.

4. DELINEATORS SHALL BE ORIENED SUCH THAT FACE OF THE SIGN IS PERPENDICULAR TO

TRAVEL LANE.

DELINEATORS \":l ;;,,, .. -- , -~-r. . . WHIH. EDGE MARKING I Q :-2\ .. , f W = WIOT~ Or _,_ • 2 ASPH/\I_ I __

- - -6~s-1(M~:~~1 ,, lcM~;j~ I - _--_-- DIRECTION

TRAVEL DIRECTION EXISTING ROADWAY ----

F'LAN VIEW

Page 49: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

12I 12=r

5' MAX.

5' MIN. w;:

•d~j iVl~LL_T__L ~:

36" I I

-~~8" x 8" TREATED POST '" x 1 2" TREATED LUM3ER RED & WHITE REFLECORIZED PANELS TO MEET NCDOT STANDARDS AND SPECIFICATIONS PANELS TO BE NAILED TO POST WITH 16 PENNY GALVANIZED NAILS.

\JOTES:

BARRCADE TO BE ERECTED ACROSS ENT'RE ROADWAY INCLUDING CURB & GUTTER.

ADVANCE WARNING SIGN W1 L-1 (DEAD END) SHALL BE PLACEC JL;ST AFTER LAST INTERSECTING STREET.

SMITHFIELD NORTH CAROLINA

STAl'JDARD DETAIL AND SPECIFICATIONS MANUAL

Drcw:ng 0319

Dote

Page 50: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

HEADWALl.S WINGWALLS

ON BOTH ENDS

CONDUIT

00 • r,t'2 "000 0 a: t,,1.., n> ~ '""'~ .... ~ "'i ~~ =~

~ ~ ~ f;; ::c: g rjl.., 1-11

~m ~i:::; ~ g-;; ~t"' ot-1 tj ~~ t-1~ 0 ~l::i .... ~ . • t-1

>~ ~

llTHONIA WAI.L-PAK TWP 1 SOF TWPWG WIRE GUARD, OR EQUAL

LIGHT

l.i ,. ~ \ . / I =i ' . ., L • / Ill

SEALING OF FIXTURES TO DESIGNED IN ACCORDANCE IES STANDARDS

PRECAST CONCRETE BOX CULVERT CONFORMING TO ASTM 789M OR ASTM C 850M

4 •

0.5% MIN. SLOPE

FRONT VIEW

NOTES: APPROPRIATE SIGNAGE MAY BE REQUIRED AT ENTRANCE TO INDICATE NARROWING TRAIL WIDTH AND LIMITED VERTICAL Cl.l:.ARANCE.

• 4

.JOINTS TO BE SEALED WITH !v1ASTIC THEN GROUTED WITH NON-SHRINK PORTU\ND CEMENT GROUT

T / ·. . ,

O' MIN. . 4

1'

' ~ .

10' MIN.

LITHONIA WALL-PAK TWP150F w/ TWPWG WIRE GUARD, OR APPROVED EQUAL

' A

E

~

- ---

Page 51: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

f­l ()

in LL 0

LlJ z :=:i

w z

(/)1

I C)

0 O:'.:

w z 5 _}

L0

~ c-u. 0

EJ ~

~

30IS

SMITHFIELD NORTH CAROLINA

STA.~ARD DETAIL AND SPECIFICATIONS MANUAI,

Intersection Sight Distance Stoa Control (Through Street 25 to 35 mph)

Page 52: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

in M

in M

LL 0

!­w I Z<..'.l :J ui

0 "'

0 "'

,;J LL z o::i w __J __Jc;J

o> o< -(Y 2!-

Ld _ _j __lW O> O<l'.: -Ct'. 2!-

N I

C ...I w

\ s:: '- J 2'.JlS JQ S

------

I

I

/

/

IW ·w

Q::'.

I (/) !

jI L:J

i :J

I~ ,I .I­I

SMITHFIELD NORTH CAROLINA

STANDARD DETAIL A;'\fD SPECIFICATIONS MANUAL

Drawing 0322

Co,.,tro::ed Inter- Cote - Above 45 mph) 1/14/2000

Page 53: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

SECTION 4.00 SOIL EROSION AND SEDIMENTATION CONTROL

4.01 SCHEDULING

Temporary and permanent erosion control measures shall be provided for all land disturbing work in accordance with an erosion control plan approved by the NCDEHNR for sites where over an acre of land is disturbed. The Town reserves the right to require that soil erosion and sedimentation control measures be established for sites where disturbed areas will be less than one acre. All permanent erosion control measures shall be incorporated into the work at the earliest practical time. All temporary measures shall be maintained until the permanent measures have taken effect. Temporary and permanent measures shall be coordinated to provide effective and continuous erosion control throughout the construction and post-construction period to-minimize siltation of streams, lakes, reservoirs, and other impoundments, ground surfaces, and other property.

4.02 TEMPORARY MEASURES

Silt Fence shall be installed at the toe of all fill slopes and any other necessary locations as required. Silt fence shall be erected in accordance with Standard Detail 4.01.

Diversion Ditches shall be installed at the top of cut and fill slopes and any other necessary locations as required. Diversion ditches shall be installed in accordance with Standard Detail 4.08.

Construction Entrances shall be installed at all points of access to construction sites. Any access point which does not have a construction entrance shall be barricaded to prevent its use. Construction entrances shall be installed in accordance with Standard Detail 4.07.

Sediment Pits or Filter Basins shall be installed at all points where accumulated runoff is released to natural drainage channels as required. Sediment pits and filter basins shall be sized to hold 1800 cubic feet of sediment for every acre of denuded area tributary to the structure. Sediment basins shall be installed in accordance with Standard Detail 4.02. Filter basins shall be installed in accordance with Standard Detail 4.03 4.05.

Temporary Seed is the use of rapid growing annual grasses, small grains or legumes to provide initial, temporary cover for erosion control on disturbed areas for less than twelve (12) months. Seed bed preparations and soil amendments shall be in accordance with the method described under "Seeding and Mulching".

Seeding and Mulching shall be done immediately behind construction. All disturbed areas shall be dressed to a depth of 5 inches. The top 2 inches shall be pulverized to provide a uniform seedbed. Agricultural lime shall be applied at the rate of 95 lbs./1000 sq. ft. immediately before plowing. Grass seed shall be applied at the rates outlined in Tables 4.1 and 4.2.

SMITHFIELD~ HORTH CAROLINA ~

STANDARD DETAIL AND Drawing SPECIFICATIONS MANUAL SPEC4_ 1

SECTION 4 Date EROSIOIN AND SEDIMENTATION CONTROL 2/1/2000

Page 54: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

5-10-10 fertilizer shall be applied to all disturbed areas at a rate of 21 lbs./1000 sq. ft. mulching shall consist of small grain straw applied at a rate of 70 lbs./1000 sq. ft. Mulched areas shall be tacked with asphalt or other approved method sufficient to hold the straw in place, 200 to 400 gallons per acre.

If active construction ceases in any area for more than 30 days all disturbed areas must be seeded, mulched, and tacked unless written approval is granted by the Town.

4.03 PERMANENT MEASURES

Ground Cover

After construction is complete, all disturbed areas shall receive a permanent ground cover in accordance with the seeding and mulching schedule in Section 4.02 "Seeding and Mulching". Permanent seeding and temporary seeding differ only in the type of seed to be used annual versus perennial.

Permanent Ground Cover is the establishment of perennial vegetation cover for periods longer than twelve (12) months. Seed bed preparations and soil amendments shall be in accordance with Section 4.02 "Seeding and Mulching". As a part of permanent seeding, maintenance may be required to maintain vegetative growth for twelve (12) months. This maintenance shall be considered a part of establishing permanent ground cover.

Riprap Dissipation Pads and Riprap Protection

After construction is complete, all points of stormwater release shall be protected by riprap dissipation pads designed to reduce discharge velocities to nonerosive levels.

The dissipation pads shall be designed and constructed with either an engineering fabric or washed stone barrier between the dissipation pad and the natural ground. Calculations shall be furnished to indicate the sufficiency of the dissipation pads specified. Riprap pad design shall be in accordance with NYDOT or SCS methods. Filter fabric, or a washed stone liner shall be used on all sediment basins, riprap dissipators, or channel designs.

4.04 COMPUTATIONS

Erosion and sedimentation control measures, structures, and devices shall be planned, designed, and constructed to control the calculated peak runoff from a 10-year frequency storm. Runoff rates shall be calculated using the USDA Soil Conservation Service Method, the Rational Method, or other acceptable calculation procedures. Runoff computations shall be based on rainfall data published by the National Weather service for this area.

4.05 CONSTRUCTION SEQUENCE

The construction sequence on projects shall be as follows:

SMITHFIELD~ HORTH CAROLINA ~

STANDARD DETAIL AND Drawing SPECIFICATIONS MANUAL SPEC4_2

SECTION 4.00 SOIL Date EROSION AND SEDIMENTATION CONTROL 2/1/2000

Page 55: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

1. Sedimentation and Erosion Control Plan Approval NCDEHNR/Town; 2. Install al erosion control measures as required; 3. Proceed with grading; 4. Clean sediment basins when one-half full; 5. Seed and mulch denuded area within thirty (30) days after finished

grades are established; 6. Maintain soil erosion control measures until permanent ground cover is

established; 7. Remove soil erosion control measures and stabilize these areas.

END OF SECTION 4.00

SMITHFIELD 0 HORTH CAROLINA

STANDARD DETAIL AND Drawing SPECIFICATIONS MANUAL SPEC4_3

SECTION 4 SOIL Date EROSION AND SEDIMENTATION CONTROL 2/1/2000

i

Page 56: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

8' MAX.

VARIABLE AS DIRECTED BY THE ENGINEER

~ • I'! § ~00 0~ 0.. t,;1,-:i ... iilll a n~ ,_t-1 a. Se 1-i

MIN. 10 GA. LINE WIRES

FRONT

[ !:2i :C ai-i I NOTES:

~ Sc £! a USE SILT FENCE ONLY WHEN DRAINAGE AREA ~ ~~ ,,,_..---;;a DOES NOT EXCEED 1/4 ACRE AND NEVER IN : ~ ~ SIG t-1 AREAS OF CONCENTRATED FLOW

;:;: ~ t ~ tr.I * FOR REPAIR OF SILT FENCE ;;;-1 > e = ._. FAILURES, USE NO. 57 g I'.'-' ;: a;;-- WASHED STONE

(1) \:, I FOR ANCHOR WHEN SILT FENCE

0 IS PROTECTING CATCH BASIN.

~ 0 0 Q .., ,..._ Q

~ (1) 0 :I'; "... ~ -· N 0<.5 0 ~

0 0

MIN. 12 1 /2 GA. INTERMEDIATE WIRES

/ STEEL POST f ,,,,,-- WOVEN WIRE FABRIC i. ,,-- SILT FENCE FABRIC

I

! I ~I llliil ~ N t')

SIDE VIEW

FILL SLOPE

/ GRADE

OVER SKIRT*

Page 57: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

U) M' 0 ::J 0. 0 r.,; cl •,:n~

i:"'.1.., ;o §i ui' (1) ..,

8~ I [lJ 0

'""t::; .., ii] ~t,,J

(/) i~ (l) o_

3" (1) ~~ ;;. [lJ 0 ~-::,

~o 0 0

0~ ,+ (D

-1'> -· 0::, N<ll

-~ olC ~ .... =~ n::C: >~ ~ .... t-tt,j .... =t-1 t:,

(0

EMERGENCY SPILLWAY CONSTRUCTED OVER UNDISTURBED GROUND AND ARMORED WITH RIP RAP

SEDIMENT TRAP

CMP RISER-PERFORATED --~

WATER LEVEL DURING STORM

SEDIMENT STORAGE

FILTER

CONCRETE BASE -

ANTI - SEEP

CMP OUTLET PIPE

CROSS SECTION

EARTH DAM

EMERGENCY SPILLWAY ELEV.

MINIMUM SLOPES 2 1 /2 : 1

EARTH DAM

DISSIPATOR PAD RIP RAP

Page 58: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

I - 5' MIN . ., I 1.5'

5' MAX.

NOTES: 800 cu.

1 . USE FOR DRAINAGE AREAS NOT EXCEEDING 5 (FIVE) ACRES.

2. EARTH BERM SHALL BE STABILIZED ACCORDING TO TOWN SPECIFICATIONS.

DRAINAGE AREA (ACRES)

1 2 3 4 5

1

1 WEIR LENGTH

(FT.)

4.0 6.0 8.0

10.0 12.0

CROSS SECTION

~ 4' MIN.

FILTER FABRIC

I OVERFILL 6" FOR SETTLEMENT

DIMENSIONS SHOWN ARE MINIMUM ....l ...J

~ .Cl) < 00 !I ~ ~~ = [ §~ := .... ~ ~~ ml-I u >-l ::c ~ ;~ ~ u oo>-l ~ ~ ~~ i,o.,_. -, ~ fa gi ~ ..... ~ ~- •t--1 CJ >- t,

• • co 0 -, r+ 0 O (D .i,,. :,:

0 -· CJ §; tO *

G::

~ ::;E

tD

I · 3' MIN. -I E SECTION

NTENANCE

SIDE SLOPE MAX

EMERGENCY BY-PASS 6" BELOW SETTLED TOP OF DAM

INSPECT TEMPORARY SEDIMENT TRAPS AFTER EACH PERIOD OF SIGNIFICANT RAINFALL. REMOVE SEDIMENT AND RESTORE TRAP TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN A DESIGNATED DISPOSAL AREA AND REPLACE THE CONTAMINATED PART OF THE GRAVEL FACING.

CHECK THE STRUCTURE FOR DAMAGE FROM EROSION OR PIPING. PERIODICALLY CHECK THE DEPTH OF THE SPILLWAY TO ENSURE IT IS A MINIMUMOF 1.5 FT. BELOW THE LOW POINT OF THE EMBANKMENT. IMMEDIATELY FILL ANY SETTLEMENT OF THE EMBANKMENT TO SLIGHTLY ABOVE DESIGN GRADE. ANY RIP RAP DISPLACED FROM THE SPILLWAY MUST BE REPLACED IMMEDIATELY.

STABILIZE THE EMBANKMENT AND ALL DISTURBED AREAS ABOVE THE SEDIMENT POOL AND DOWNSTREAM FROM THE TRAP IMMEDIATELY AFTER CONSTRUCTION WITH SEEDING.

Page 59: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

et:: w ti :;E <(

0 (I) w :;E j:::::

N

o 0 0

~ 0..

w _J L,_ I.J.. <( co

w (') Cl'.'.

o1 zu :::i (/) o-Cl'.'. o 0o zZ _<(

I-0 (/] w:c - I-Cl'.'. -:::i :s:

w (D 0 (') w I-et:: u I-<( «: z :c a::: w u m-(/) (.)

0 < C: "1- LL ?<:::i ~ (/]

w > I-u w (L (f) I}:'. w (L

et:: 0 '.;i: 0.. (/) (/)

0 0.. <( et:: 0.. . _CJ O'.'.O

I 'I-Ow

8::E :S:o >-w _J> o..o wet:: (D 0..

0.. >- «: <( et:: ~w

(J) w:C w _JI-f- 1.i..O

LL 0 «: Cl'.'. z mo

SMITHFIELD ~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

Gravel & Rip Rap Filter Basin

Drawing 0403B

Date 1/12/2000

Page 60: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

------ ---

./

~

CLASS 1 RIP RAP SEE SECTION THRU BASIN BELOW

- ----------

\\\,\1

// I /~ /

/

/✓ --

/ / 1 /./

/

/ / RIP RAP HEADWALL

/

#5 WASHED STONE 1' THICK X 3' HIGH MIN.

/

r-- / /

C)

' Q .112 < (1) - 00 ~ 011 R' ~

§ i ~ .... ~§ =11114 ~ n::C:

21 ~~ -i r,:,""3 >~I ~ '

it ~ ....

~ OJ ,..... (1)

(/)' t:~ 3 OJ =t.-1 Q (/)

s· t:,

0 • o 0 '

N <n O ~ ·. "- .;,,. -· N O :J g -i,. <O * 0

PERSPECTIVE VIEW

PIPE INVERT

RIP RAP HEADWALL

NOTE: ;o 0'1l8811', ! ·? -fl:QW -:_

MAX. SEDIMENT DEPTH (CLEAN OUT POINT)

SECTION BASIN, FILTER AND CU Pl

NOTES: GRAVEL & RIP RAP FILTER BERM BASIN DETAIL IS DESIGNED TO PROTECT EXISTING PIPE INVERTS THAT DRAIN 1 D ACRES OR LESS.

Page 61: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

CONCRl:.lT BLOCK CATCH BASIN

CULVERT rl

PIPE-----( \ /

\ J t

PERSPECTIVE VIEW

#5 WASHED STONE FILTER

SEDIMENT STORAGE ZONE

---GALVANIZED HARDWARE CLOTH W / 1 /2" GRID

AT END OF PROJECT, CATCH BASIN CAN BE RAISED AS NEEDED PLUGGING OPEN COURSE OF BLOCK WITH MORTAR

RISER CAN BE BUILT AS A STANDARD CATCH BASIN/JUNCTION BOX

WEEP HOLES) AND BE UTILIZED AS SUCH WHEN PROJECT IS STABLE.

GALVANIZED HARDWARE CLOTH 1 /2" X 1/2" GRID FLOOD STORAGE ZONE

SEDIMENT STORAGE ZONE (TOTAL BASIN CAPACITY)

~ . ~ 0 00 =I: 0 '"Cl 00 ,..._

~~ '°1-1 () ::r

:ita-1 (0 0

~~ U)

n:J:: 5·

;;,J ..... t:i ;;;· ~t"lj :a--... (D 00.., .....

~~ ~ .... "' i ~~ t"'I~ .... r:t-t

~ ~

~ 0 0 ,o ' ~ ,..._ 0 N ffi O :i, "' -is.-· N o_g 0 (J1

0 0

1.5'

COURSE OF BLOCK LAID SIDEWAYS ON 3 SIDES OF CATCH BASIN

FLOW CULVERT PIPE

, >0 >0~R . ~vm'0~'0~'0v,:~y~~'0v."'"'~'0'7✓~~~~Wvm'0"'' /~0,>»✓✓,: ✓»✓»✓v✓»✓»✓»/»/.0-V-/.~0¥/2000«::w«<ww«

CONCRETE FOOTING PAD

#5 WASHED STONE FILTER LAID AGAINST HARDWARE CLOTH (1: MAX.

CLEAN OUT POINT (1/2 DEPTH SEDIMENT STORAGE

VI

Page 62: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

-I

w z 0 1-(/)

0 w :c (/) <(

s:

w CL g (/)

> w 0 (/)

w 0.. 0 _.) (/)

(.'.) z i= (/)

~

>-(D

0 w ci ~ w 201'.t'. Ct'. z-w <(::) 1-- 0 w>-w 0 I Ct'.

IO..W 1-- <( Cl 0 Ct'. 4'. - C) Ct'. s: 0 0

0..1-0 0 (fl z I-<( I-c.,z 1-- z w Gt:i~ w x 8 I W (I)

(/) w f-0 z

2 <( 0

w I I-

Oz i-o Z--~ O...N <(-Ct'. =:!

co 9:: ;:x: Ct'. (/)

>- 0::: WO :0.::: I..,_

(L w <( z Ct'. 0

I-0... (/)

a::: 0 0 w w I >- (/)

w 4'. Y'. s:

>

SMITHFIELD ~ HORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS :MANUAL

Check Dam

Drawing 0406

Date 1/12/2000

Page 63: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

I· ·I

z 2'

l[)

(

h

z 0 f­u w (f)

(f) (f)

0 0::: u

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

Construction Entrance

Drawing 0407

Date 1/12/2000

Page 64: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

0 GI

I-

{)

0

{)

(I

/J {)

0 0 Z

"-' w z 0 I­(/)

()

· I

z s 0...

/J ()

( z 0 F u ::J a:: I­(/)

z 0 u

~~ h

(D

a::: 0:: :::lw ul= I- ::J ~0

0 :,,:z U<( 0

~~

(.'.)~

~ :s: 1-0 (/) <( xO WO::

z 0 f-0 w (/)

(/) (/)

0 er:: 0

(/) w f-0 z

vi I-

(l)Z W::J

w u

0 z_1 0 0:: z <( <( a::: <( ~w ~F <( 0 Oal (j)J: zZ z za::: I- w~ ;::'. ;::'. ::J w

(/Ju IO oui (/)

10 I- I- 1-W

I 0:: l.() G!z a:::W ::i >-r-; F WI: I") t')(/) Q_J Z:::!

z 0.::E 0

OX ::J _J w (/)~ zw <Cu

z 01-z w .0 WO<( :::J ::J ci oz ol-a:::

I- t;;> Ool-(L(.'.) CLz (/) 0 <CoZ <(_

z . 2 <Cw w(I) 000W w 3:a:::3:0:: aJoZ u_J OCL 0 _10 z...:

<( LL ~ :::ii= <{ ::J o>-oo 200 O'.:O

:s: ::J 1--1-<Ct-o a::: z~ a::: :s: n::o OIi- wo wWwI Ct:: u (/) z LL :2: LL G:i m-Z (/)-

w 0:: w <(IO ILL 0:: O 0:: 2 lL :S: U 1-0 I I

SMITHFIELD ~ HORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

Residential Construction Entrance

Drawing 0408

Date 1/12/2000

Page 65: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

w 0.. 0 _j V)

_j _j

c;:

Cl'.'. 0

1-::) u 0.. w w tn

z 0 1-u w (f)

U1 U1 0 Cr'. u

w

; ~ ' LI'.'.

0

1-::)

u 0.. w l:::l U1

3: w > z :s (l_

SMITHFIELD~ HORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

Diversion Ditch

Drawing 0409

Date 1/12/2000

Page 66: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

ITT-- =---!c--..

4" TO 12" m=---1

t J1~1'ffim111_ Ill- t 6"

GRAVEL BEDDING ~ OR FILTER tBRIC

PARABOLIC-SHAPED WATERWAY WITH STONE CENTER DRAIN (SHAPED BY BULLDOZER)

00 • I'! ~00 o EC l'."J '"'3

§i = .... GRAVEL BEDDING OR FILTER FABRIC

_[ d

-ill-Ill-"

TRAPEZOI

w

c: 8§ ma-i ~ ~ = ~ ~t;; ~

V-SHAPED WATERWAY WITH STONE CENTER DRAIN (SHAPED BY MOTOR GRADER)

0 00,.., ""' , r 1111 0 p ....

[ ~ lataii (J) ~ .... =t-1 t:, ~

NOTES: TO BE USED WHERE EXCESSIVE STORMWATER VELOCITIES PROHIBIT VEGETATIVE LININGS. SIZE OF STONE MUST BE DETERMINED BY APPROPRIATE DESIGN PROCEDURE. DIMENSIONS FOR d & W VARIES ACCORDING TO DESIGN.

OR FILTER FABRIC

Page 67: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

FILTER

1 /2 DIAMETER OF PIPE OR 12" WHICH EVER IS GREATER

CAPACITY OF PIPE CULVERTS TOGETHER = BANK FULL FLOW

COARSE AGGREGATE 6" DEEP

ELEVATION

-l Cl.l (D -= 00 3 r,,J..;;

-~ =IC ~ ....

COARSE AGGREGATE \ ~

\J (")~

3 Ss .... (")~ '< > (/J ..;; r+ .... t:,

~ ~t,,J 3 i'll~

~E=

~i

=~ n::Z: >"" ~ .... t:~ =t-1 t:, 25'

MINIMUM

TOP OF BANK-- ~

EARTH FILL COVERED BY LARGE ANGULAR ROCK

EARTH FILL COVERED BY LARGE ANGULAR ROCK

Page 68: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

\---z 00 -<e 1-0 t;3 0::

_J Ui w z z IO z 0 <( <(W I 0 0.. u !XO

0.. _J

2 o_(/) <( 0 <( w x 0:: w<C I-(/) z:;;:

0~ I- .. (/") l{)

I f-0 .....I 0

Ct'.'. w ~ c;::

Ct'.'. w > 0

w z 0 f-(/)

I I-0 _J

0

0:: w ~ c;::

Y'. z <( CT)

3: 2 0 ~ .....lz Ct'.'. u...o I-wui (/")

00'.'. _j ~w <( Ct'.'.~ z ::i 0 CJ

C> (/j a:: 0

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

Temporary Stream Crossing Option

Drawing 0411B

Date

1/12/2000

Page 69: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

BURY BOTTOM OF PLYWOOD

,,....,,,---- UPSTREAM END OF STORM DRAIN

.• 4

"

• "

4· " .. . .

·-"' .

-... 4 '(/. •.

. i. 4

"· 4 .. "

"' L1o' <f 4. 4··

4,4·

NOTE, ALL PARTIALLY COMPLETED STORM ORAINS - - - - - - -~

SHALL BE PROTECTED AT THE END OF EACH DAY IN ACCORDANCE WITH THESE DETAILS.

tll "d 00 t'"J""

§~ 2§ .... 0~

i~ ~i

."'2 oEC a::1 n::C =-~ ~ .... t:~ =t-1 t:,

,o 00 ~ 0 -,

N;;;- 0~ '-.. .J:>. -· N ~ :i g N'° it

0

WASHED STONE FILTER ACROSS PIPE INLET

STEEL FENCE PLYWOOD INLET PROTECTION POST

UPSTREAM END OF STORM DRAIN

·,4' . <f

4

" 4· .. ..

STONE FILTER INLET PROTECTION

. . ·~<I '

L1o' <1

· . .,

·<?

4·. · 4 . "'

i <f' •

OVERFLOW

1/3 PIPE DIAMETER

J

1/3 PIPE DIAMETER

Page 70: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

CONCRETE BLOCK

CONSTRUCTION SPECIFICATIONS DEWATER ING ------------1 . LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE

ON ITS SIDE ON THE BOTTOM ROW TO ALLOW POOL DRAINAGE. THE FOUNDATION SHOULD BE EXCAVATED AT LEAST 2 INCH BELOW THE CREST OF THE STORM ---DRAIN. PLACE THE BOTTOM ROW OF THE BLOCK AGAINST THE EDGE OF THE STORM DRAIN FOR LATERAL SUPPORT AND TO AVOID WASHOUTS WHEN OVERFLOW OCCURS. IF NEEDED, GIVE LATERAL SUPPORT TO SUBSEQUENT ----.___ ROWS ~: PLACING 2x4 WOOD STUDS THROUGH ----­BLOCK pPENINGS.

2. CAREFULLY FIT HARDWARE CLOTH OR COMPARABLE WIRE MESH WITH 1/2-INCH OPENING OVER ALL BLOCK OPENING TO HOLD GRAVEL IN PLACE.

3. USE CLEAN GRAVEL,3/ 4-TO 1 /2-INCH IN DIAMETER, PLACED 2 INCHES BELOW THE TOP OF THE BLOCK ON A 2:1 SLOPE OR FLATTER AND SMOOTH IT TO AN EVEN GRADE. DOT #57 WASHED STONE IS RECOMMENDED.

OJ 0 i .. ~ 0 r,_, ,_,. a: ::, -= !"A 0 0.. ~ >-l pi, ~ 9~ a-41-11 ~ ~~ mt-ii I ~~ ~::C: ~ ~~ pi, 1111 ~ ~f< 01-11 l ~~ t:~ it !!!t-1 ~r ,,,,,. ~

--::::_o 0 0 ~ Cl '

N <D O ~ " +> -· N ~ ::, g (.,J <D * 0

----------

-------

----------------- -- -------·----

2:1 SLOPE, GRAVEL FILTER

TEMPORARY SEDIMENT

POOL7

~--

1 'MIN. 2'MAX.

1=111-111~

r111 11,111 1,1~1 ... .. .ill, Ii' I~, I II 11~,11 II Ii~ I" ·,j

- 111 111 I ' 1-111=

'I=

WIRE SCREEN

Page 71: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

X 0 Q)

w 0:: LL

~o 0 o_ 0:: 0 <t: f-

U) I f- 0 U) 0 f-0 w (L N (J) -o _J z z ~ :';; w

\ _J f-w <t: X

2 0 w

\/

w z ~ U)

0 w I U)

~ l'-1.()

~

SMITHFIELD ~ NORTH CAROLINA ~

STANDARD DETAil.. AND SPECIFICATIONS MANUAL

Standard Catch Basin / Yard Inlet Protection

Drawing 0414

Date 1/12/2000

Page 72: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

U) :::, 0 C

0. (D -, IJ)

U) -I ~·o g-~

(I)

0 :=i:..f!:,. o· :::J" (D IJ)

(/]

0 -0 (I) IJ)

\

r,J .r,J ~(71 =a: n~ "' s~ ~ .... ~§ :at-ii ~~ n::C: r,i>-l > 111'.t !~ ~--­~~ t:~ =t-1 t, -(~-1~0 ......... .-,... 0 D

m er :.=

~J * .I>,.

TABLE 4.1 SHOULD SI DITCH SLOPES

(MAX. 1)

DATE PLANTING RATE

AUG 1 NOV 1 300 LBS/ACRE NOV 1 MAR 1 TALL AND ABRUZZi RYE 300 LBS/ACRE MAR 1- 15 TALL FESCUE 300 LBS/AC APR 15- JUNE HULLED COMMON BERMUDAGRASS 25 LBS/ACRE JULY 15- AUG 15 TALL FESCUE AND ***BROWNTOP MILLET LBS/ACRE

CONSULT SOIL CONSERVATION SERVICE FOR ADDITIONAL INFORMATION CONCERNING OTHER ALTERNATIVES R OF DENUDED AREAS. ABOVE VEGETATION ARE THOSE WHICH DO WELL UN LOCAL

CONDITIONS; 0TH SEEDING RATE COMBINATIONS ARE POSSIBLE

***TEMPORARY ACCORDING OPTIMUM SEASON FOR RED PERMANENT VEGETATION. DO NOT ALLOW TEMPORARY COVER TO GROW OVER 12 INCHES IN HEIGHT BEFORE MOWING, 0TH FESCUE MAY SHADED

Page 73: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

DATE TYPE

ES, SLOPES 2: 1)

NG RATE

MARCH 1- JUNE 1 SERICEA LESPEDEZA (SCARIFIED) AND

50 LBS/ACRE

120 LBS/ACRE

10 LBS/ACRE

25 LBS/ACRE

120 LBS/ACRE 25 LBS/ACRE 30 LBS/ACRE

MARdH 1 - APRIL 15 TALL FESCUE

MARCH 1- JUNE ADD WEEPING LOVEGRASS OR

MARCH 1- NE ADD HULLED COMMON BERMUDAGRASS

JUNE 1 1 ***TALL FESCUE AND ***BROWNTOP MILLET ***OR SORGHUM-SUDAN HYBRIDS

SEPTEMB 1 MARCH 1 SERICEA LESPEDEZA (UNHULLED UNSCARIFIED) AND TALL FESCUE

70 LBS/ACRE 120 LBS/ACRE 25 LBS/ACRE

(/) ::r 0 C

n:

,_ II.I ~00 =I: §i == ....

~~ ~~ :z:t-i (1)~ ~s ::C (1) --, U)

o(]) oi:i n ;:.,-l>- zt,,.1 > ti~ ~:3 ~ ~i t:tti al ~ ..... rn > a;;--t:I ..:::'._;? -;D co _J.rl-0-, r-.., (l) z ~ ~ ro s· . 0 .j>. '° * 0 , 0 N

ADD ABRUZZI RYE

CONSULT SOIL CONSERVATION SERVICE FOR ADDITIONAL INFORMATION CONCERNING OTHER ALTERNATIVES FOR VEGETATION OF DENUDED AREAS. THE ABOVE VEGETATION RATES ARE THOSE WHICH DO WELL UNDER LOCAL CONDITIONS; OTHER SEEDING RATE COMBINATIONS ARE POSSIBLE

***TEMPORARY - RESEED ACCORDING TO OPTIMUM SEASON FOR DESIRED PERMANENT VEGETATION. DO NOT ALLOW TEMPORARY COVER TO GROW OVER 12 INCHES IN HEIGHT BEFORE MOWING, OTHERWISE FESCUE MAY BE SHADED OUT.

Page 74: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

SECTION 5.00 PIPE TRENCHES

5.01 EXCAVAllON AND PREPARATION OF PIPE TRENCHES

Trenches for water distribution sanitary sewer lines, force mains, and storm sewer lines shall be excavated to the required depth to permit installation of the pipe along the lines and grades shown on the construction drawings. The minimum trench width at the top of the pipe shall be at least 18 inches greater than the outside diameter of the pipe. Where excavation is in rock, the rock shall be removed to a depth of at least 6 inches below grade and shall be backfilled with materials in accordance with these specifications. Wet trenches shall be stabi1ized with #78 M stone or with a base layer of stone.

5.02 PIPE LA YING AND BACKFILLING

All pipe sholi be laid in accordance with the manufoctu recommendations. The subgrade at the bottom of the trench shall be shaped to secure uniform support throughout the length of the pipe. A space shall be excavated under the be of each pipe to provide space to relieve bearing pressure on the bell and to provide room to adequately make the joint. Open ends of pipe shall be plugged with o standard plug or cop at all times when pipe laying is not in progress. Trench water shall not enter the Backfill material shall be free from construction material, debris, frozen material, organic material, or unstable material. The top 2 feet of backfill material shall be free from stones greater than 4 inches in diameter.

Under roadways and extending at a slope of 1 to 1 beyond the back of curb, measured perpendicular from centerline, backfill shall be compacted to a density of no less than 95% standard Proctor maximum dry density as measured by AASHTO method T99. Backfill shall be placed in lifts of 8 inches or less of the uncompacted soil. Other fill material shoil be compacted to o density of no less than 90% of the maximum dry density as measured by AASHTO method T99. Backfill material shali be placed in lifts of 12 inches or less of the uncompocted soil. Suitable backfill material shall be utilized and compacted in accordance with Town compaction requirements and the pavement repair shol! be in accordance with Standard Detail 5.01.

All trenches shall be properly backfilled at the end of each working day. All pavement cuts shall be repaired within a maximum of three (3) days from the date the cut is made. If conditions do not permit a permanent within the given time limit, permission to make a temporary repair must obtained from the Town Engineer.

In locations where backfill material is temporarily stockpiled on the roadway surface, a layer of 1 1 /2 inches of screenings shall be used between the pavement surface and the backfill material.

5.03 BORING AND JACKING

All crossings of Town streets shall be by bore and jock method in order to minimize pavement cuts and maintenance problems. The Town shall recommend that all crossings of State maintained streets within the Town corporate limits be by the bore and jack method. In coses where circumstances such as utility conflicts wil! not allow crossing by bore and jock method, the -own may consider approving other methods of crossing with additional requirements to minimize pavement failure and maintenance problems.

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 5.00 PIPE TRENCHES

Drawing SPEC5_1

Dote 2/1/2000

Page 75: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

In locations where open pipe trenches ore not allowed, dry bore and jock operations may be allowed. Smooth wall or spiral welded steel pipe may be jocked through dry bores slightly larger than the pipe bored progressively ahead of the leading edge of the advancing pipe. The spoil material shall be mucked by the auger bock through the pipe during the boring operation. As dry boring new section of the encasement pipe shall be butt-welded to the section progresses, each previously jocked into place.

The steel pipe shall be manufactured of grade 'B' steel with a minimum yield strength of 35,000 psi in accordance with ASTM A 139 and A283. When used along or under a roadway maintained by NCDOT, the encasement pipe shall be coated to meet NCDOT requirements.

If voids ore encountered while installing encasement pipe thirty (30) inches and larger, grout holes shall be installed at ten (10) foot centers and filled with 1 :3 Portland cement grout at sufficient pressure to prevent settlement of the roadway, unless NCDOT approval stipulates otherwise. Other grout mixtures may be submitted for approval.

In the event that an obstruction is encountered during the boring and jacking operation, the auger is to be withdrawn and the excess pipe is to be cut off, copped, and filled with 1 :3 portlond cement grout at a sufficient pressure to fill all voids before moving to another boring site.

Size and wall thickness of smooth wall or spiral welded encasement pipe shall be as follows:

Pipe Size (O.D.)

12 3/4" 16" 18" 20" 24" 30" 36"

Wall Thickness (in.)

0.188 0.250 0.250 0.250 0.250 0.312 0.375

Cosing pipe shall be installed with a minimum cover of 3 feet under pavement.

All carrier pipe shall be slip joint ductile iron pipe resting on treated timber skids as shown on Standard Detail 5.02 so as to prevent damage to the pipe bell. Pipe bells shall not contact the interior of the cosing pipe. No blocks or spacers shall be wedged between the pipe and the top of the cosing. Cosing pipe shall have the following minimum sizes:

Carrier Pipe Size (in)

4 6 8 10 12 14 16

Casing Pipe Size (in}

12 3/4 12 3/4 18 20 24 26 28

END OF SECTION 5.00

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 5.00 PIPE TRENCHES

Drawing SPEC5_2

Dote

2/1/2000

Page 76: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

CONCRETE PATCH (3000 P.S.I.)

z 2

r<)

~ ... r--2

SAWED PAVEMENT CUTS

(REPLACE WITH 2"1-2)

~: 8" STONE

PIPE DIA.

+ 18"

DO NOT DISTURB EXIST. STONE

SHALL BE GRANULAR MATERIAL OR FLOWABLE FILL TO PREVENT SETTLEMENT

PATCH SHALL BE 6" 3,000 P.S.I. CONCRETE OR 7" BINDER COURSE

Ct:: w > 0 0

r<)

DO NOT DISTURB EXIST. STONE

::, rn ---a: g- ~~ 0 ci_ ri> ,., CONCRETE PAVEMENT ASPHALT

~-I sr-~ ~ .... u""" rli::, .,..~ 9.~ >i .... ""IO >-I (/)::,- """ .... <1>Q oi::, n .... O::i '.2:t"l ...... c>:o. rn>""l --~ ~ ci' ! ~ ,., .... ~ ~i ctP.I 1 ~ =t-1

'=' 0 00 Q -,

;t ~ ~-0 :, ~ '° *

CONTRACTOR:

ALL PAVEMENT CUTS SHALL BE REPAIRED WITHIN A MAXIMUM OF THREE (3) DAYS FROM THE DATE THE CUT IS MADE. IF CONDITIONS DO NOT PERMIT A PERMANENT REPAIR WITHIN THE GIVEN TIME LIMIT, PERMISSION TO MAKE A TEMPORARY REPAIR MUST BE OBTAINED FROM THE DIRECTOR OF PUBLIC WORKS.

CONCRETE TRENCH CAP ON ASPHALT STREETS SHALL BE USED ONLY DURING INCLEMENT WEATHER WHEN ASPHALT PLANTS ARE NOT OPERATING.

Page 77: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

-~ 00 0 a: "l:!rll tri ,.., '°11-1

o §i ti1t-1 on~ .... > n::C ii;· ~ __, oo -iJ ~ I:':! >"" ,, r ~ .... {l) t:l

~~ l""' 1,1 lo-I =t-1 t1 ~o oo '--- Q ....

~ ~ 0 ~ U1 -· 0:::, * N'°

CARRIER PIPE ~

PRESSURE TREATED OR CREOSOTE 3-4"x6" OAK TIMBER SKIDS

- - --\

STEEL ENCASEMENT PIPE

~OTES:

METAL "SPIDERS" MAY BE USED FOR SUPPORT OF THE CARRIER PIPE WITHIN THE CASING PIPE.

6"

3'-o"

"-v:::-._v:::-._v:::-._v~ ,. w;;0~ss ,, V,~-.,,

i-7 \

ENCLOSE ENDS WITH

I MLv,xAV'. 8" BRICK MASONRY

I\ \T\TT]

6"1 2"

__J DRAIN

q_ CARRIER PIPE

\_ DRAINAGE GRAVEL (10 CU. FT.

PRESSURE TREATED OR CREOSOTE 3-4"x6" OAK TIMBER SKIDS

CARRIER PIPE

ENCASEMENT

STEEL STRAPPING

Page 78: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

0 171 0 ii:, 1'.1.1 ~ t!j >-l ~- ~i

8§ .., Cl i t!j

tll~

;;o ! r g, ~> g ~~ 0..

GRADE 3'

2" GALVANIZED VENT AT HIGH END OF CASING

---- RAILROAD R/W

I VENT TO HAVE INSECT SCREEN WELDED TO END. VENT TO BE LOCATED AT R/W.

3'-0" ~ I PRESSURE TREATED

OR CREOSOTE 3-4"x6" OAK TIMBER SKIDS

~I " " \ E~CLOSE ENDS WITH '_!Tl I ' I- 6 2 BEVEL , 8 BRICK MASONRY

'wfZ'''l°"~"lli ~~ fj. ✓~~ .,_, (WATER TIGHT GROUT AS REQUIRED) . R<1/-'.W$'(/,

l\ \\\\\I

'\_V0,.V0,.V0,."--,~'\_V.- ----

CARRIER PIPE

WEEPHOLE AT LOW OF CASING

STEEL ENCASEMENT PIPE ~/,>«:<~-,, '<.~-- _j SLOPE TO DRAIN

.f,'I oll ::: .... =114 n::C: :S-1-fj ~ .... t: tP.I =t-1 t:,

,;

ELEVATION

DRAINAGE GRAVEL (10 CU. FT.

PRESSURE TREATED OR CREOSOTE 3-4"x6" OAK TIMBER SKIDS

CARRIER PIPE

STEEL ENCASEMENT PIPE

STEEL STRAPPING

Page 79: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

8.01 STORM DRAINAGE MATERIALS

A. Pipe Materials

SECTION 8.00

STORM DRAINAGE

1. Reinforced Concrete Pipe shall be as per ASTM C76, Table Ill or Table IV with a minimum 12 inch inside diameter. Joints shall be sealed with a plastic cement putty meeting Federal Specification SS-S-00210, such as Ram-Nek or a butyl rubber sealant.

2. Corrugated Steel Pipe or Pipe-Arch shall have a minimum 12 inch nominal diameter and conform to AASHTO M36 with pipe ends having no less that 2 round corrugations on each end. Bands for connecting pipes shall be corrugated with a minimum of 2 corrugations for each pipe. Pipe shall be fully bituminous coated with an asphalt paved invert in accordance with the requirements of AASHTO M 190 for Type C pipe.

3. ADS N-12 High Density Polyethylene Corrugated Storm Sewer Pipe shall have a minimum 12 inch nominal diameter and shall be used only in areas outside of public right of way. ADS pipe shall not be instalied under any pavement or curb and gutter, and shall be installed with Class I or Class II bedding to the spring line of the pipe. Pipe material shall meet the product specifications of ASTM F667 and shall have a smooth interior.

8. structure Materials

All storm drainage structures such as manholes, inlets, junction boxes and catch basins shall be constructed of either solid brick, solid block, or precast concrete.

1. Clay Brick shall be solid, rough, sound cloy brick conforming to ASTM C32, Grade MS. The brick shall be laid with full shove Joints, filling up the joints with mortar. The thickness of the joints shall not exceed 3/8 of an inch.

2. Concrete Block or brick shall be solid and conform to ASTM C139 as to design and manufacture. The block or brick shall be embedded in a mortar bed to form a ½ inch mortar joint.

3. Precast Concrete Manholes shall meet ASTM C478 as to design and manufacture. All manhole cones shall be the eccentric type. Manhole joints shall be sealed with o plastic cement putty meeting Federal Specification SS-S-00210, such as Ram-Nek or a butyl rubber sealant.

4. Manhole Frames and Covers shall be cast iron or ductile iron with "Storm Sewer" stamped on the cover and two 1 inch holes. Costings shall be machined to give even and continuous bearing on the full length of the frame. Castings shall be free of porosity and blow holes, and shall receive one coat of Koppers Super Service Bitumostic black paint. Paint shall be kept off of bolt threads, and surfaces shall be thoroughly wire brushed before painting. All manhole rings in roadways shall be installed in accordance with Standard Detail 7.08.

SMITHFIELD.~ HORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 8.00 STORM DRAINAGE

Drawing SPEC8_1

Date 2/1/2000

Page 80: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

5. Manhole Steps shall be of polypropylene material reinforced with a 1 /2 inch diameter reinforcing rod. They shall be designed for a vertical load of 400 pounds and a horizontal pullout load of 1000 pounds, and shall be set 1 6" on center. Holes for the installation of manhole shall not project through the manhole wall, but shall stop a minimum of one inch from the outside wall. Steps shall be at least 10 inches clear width and shall project at least 4 inches from the wall into which they are embedded. Steps in precast concrete structures shall be installed by the manufacturer.

6. Catch Basins (curb inlets) for street drainage shall be in accordance with Standard detail 8.03 or 8.04. Precast concrete boxes are allowed, but precast manholes are not acceptable for use as catch basins.

7. Headwalls and Endwalls may be cast in place per NCDOT Standard Details 838.01 through 838.75, or precast with wing walls and apron by an approved manufacturer. Installation of precast headwalls and endwalls shall be in accordance with the manufacturer's recommended installation procedures and specifications.

8.02 STORM SEWERS

A. Location

1. All public storm sewers shall be installed in dedicated street right of way or dedicated easements. tv'inimum widths of storm sewer easements shall be 20 feet for pipes up to and including 48 inches in diameter and 30 feet for pipes greater than 48 inches in diameter.

2. See Sections 6.00 and 7.00 for horizontal and vertical separation requirements between storm drainage pipe, water lines, and sanitary sewer lines.

3. The Town of Smithfield shall maintain only the storm sewer systems within Town maintained rights of way and on Town owned property. Storm drainage systems located on private property shall be maintained by the property owner(s).

4. Unless prevented by topographic constraints, storm sewer shall not discharge into front yards of lots, but shal! extend to within 20 feet of the rear property line in lots up to 1 /2 acre in size and shall extend a minimum of 150 feet from right of way in lots larger than ½ acre.

B. Sizing and Design

1. Storm sewer systems shall be designed on the basis of the 2 year storm for inlet spacing, the 10 year storm for street drainage pipe sizing, the 25 year storm for cross-street drainage, and the 100 year storm for flood plain areas. Pipes shall be designed to flow 7 /8 full.

2. Runoff rates shall be calculated by the Rational Method, SCS Method, or other acceptable procedure. Runoff computations shall be based on rainfall data published by the National Weather Service for this area.

3. For drainage areas less than 2 square miles, the Rational Method is recommended to calculate runoff. For drainage areas greater than 2 square miles, the SCS Method or other recognized method is recommended.

SMITHFIELD ~ NORTH CAROLIHA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 8.00 STORM DRAINAGE

Drawing SPEC8_2

Dote 2/1/2000

Page 81: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

4. Time of concentration (tc) shall be appropriate for the drainage area in question using Kirpich Equation (Bureau of Recio motion, 1974, p.71 ).

5. Storm duration shall equal the time of concentration (tc).

6. Storm sewer pipe shall be sized in accordance with the Manning Equation.

7. Storm sewers shall be designed to provide a velocity of at least 2 feet per second ot design flow.

8. The minimum pipe diameter shall be 12 inches where the inlet is grated and 15 inches where the inlet is not grated.

C. Installation

1. All storm sewers shall be installed to provide a true line and grade between structures.

2. Structures shall be installed at each deflection of line and/or grade.

3. The maximum length between access points shall be 400 feet for all pipe sizes.

4. No inaccessible storm drainage structures shall be allowed.

5. Pipe may enter through the corner of all structure material types except precast concrete "waffle" boxes.

6. A reinforced concrete slob designed by on engineer may be used at oversized structures to adjust an inlet to standard dimensions.

7. The minimum cover for storm sewer pipe shall be 2 feet to finished subgrade under roads and 1 foot to finished grade under nonlood-beoring areas. Trench excavation and backfilling shall be in accordance with Section 5.00 of these specifications.

8. Pipe shall not project into a drainage structure but shall be finished flush with the inside of the structure.

9. Catch basins between 5 and 20 feet in depth shall have minimum interior dimensions of 4 feet by 4 feet, and those over 20 feet in depth shall have minimum interior dimensions of 5 feet by 5 feet.

10. Each drainage structure shall have o shaped invert constructed from concrete, and o bench with o maximum 5: 1 slope. The bench shall begin at o height of one-half the pipe diameter for 12 to 24 inch pipe, one-third the pipe diameter for 30 to 48 inch pipe, and one-fourth the diameter for pipe greater than 48 inches in diameter.

11. Precost concrete structures may be installed only to depths certified as acceptable by the manufacturer.

D. Pipe Inlets and Outlets

1. Headwalls, endwolls or flared end sections shall be installed at all inlets and discharge points.

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 8.00 STORM DRAINAGE

Drawing SPEC8_.3

Date

2/1/2000

Page 82: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

2. F!ared end sections shall be installed on single pipe culverts up to and including 60 inches in diameter, and on multiple pipe culverts up to and including 36 inches in diameter.

3. Headwalls and endwolls shall be installed on single pipe culverts greater than 60 inches in diameter, and on multiple pipe culverts greater than 36 inches in diameter.

4. Precast headwalls shall only be installed at single pipe culverts.

5. Energy dissipators shall be installed at all discharge points and shall be properly sized to ensure that stormwater is re eased at a nonerosive velocity.

6. A fabric or washed stone barrier shall be installed between the dissipation pad and the natural ground.

7. The stormwater design she include scour protection for the drainage way.

8. Storm drainage channels and ditches shall be designed to carry the design flow at nonerosive velocities. Calcuiations indicating design velocities shall be provided along with typical channel cross-sections. The maximum allowable design velocity in grass channels is 4 feet per second.

9. The Town may require additional information on the impact of stormwater discharge on adjacent properties.

E. Street Drainage

1. Stormwater sho1I not be allowed to flow across streets at intersections. Drainage structures shall be provided to intercept flow prior to the radius

of intersections or the street design sha 11 provide for a continuous grade around the radius to channel flow down the intersecting street.

2. No stormwoter inlets shall be placed within travel areas of a roadway or parking lot.

3. Curb inlets shall be designed to intercept stormwater before the gutter spread exceeds 8 feet for the 2 year storm. In areas of heavy pedestrian traffic, the maximum allowable spread may be decreased by the Town Engineer.

8.03 STORMWATER IMPOUNDMENTS

Stormwoter Impoundments, where required, shall meet the following criteria:

Retention (wet) facilities shall be utilized where the upstream drainage area is ten (10) acres or greater unless otherwise approved by the Town. Detention (dry) facilities may be utilized where the upstream drainage area is less than ten (10) acres.

Retention (wet) facilities shal1 be designed in accordance with the Appendix of Section 8.00.

The following general guidelines should be followed when designing both retention and detention facilities:

SMITHFIELD ~ NORTH CAROLIIA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 8.00 STORM DRAINAGE

Drawing SPEC8_4

Date 1

2/1/2000 ~

Page 83: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

1 . Side slopes shall be no than 3: 1 and no flatter than 10: 1.

2. Both barrel and riser shall be concrete, and the riser shall be located in or near the embankment.

3. The riser inlet shall be covered with a trash rack to prevent clogging.

4. The principle spillway shall be designed for 10 year predevelopment storm; the emergency spillway shall be designed for the 100 year storm.

5. The minimum length to width ratio shall be 2: 1; The maximum length to width ratio shall be 5: 1 unless otherwise approved by this Town.

6. A maintenance access to and around the perimeter of the facility shall be provided via a minimum fifteen ( 15) foot wide gravel road adequate to withstand heavy equipment. The access road shall not cross the emergency spillway, and shall have a maximum slope of 5: 1.

7. On-site disposal areas capable of receiving sediment from at least two (2) clean-out cycles should be reserved in adjacent open space, if available.

8. All inflow points and outlet channels shall be protected by appropriately designed velocity dissipators.

9. Embankments shall allow for a minimum one (1) foot freeboard.

10. Anti-seep collars shall be installed around the barrel and a core trench shall be installed under the embankment to key it to the substrate.

11. Such facilities shall not be used as erosion control devices during construction except as approved by the Town.

12. The Town shall receive, for all stormwater impoundments, design calculations including, but not limited to, hydrographs, routing and outlet sizing, and a maintenance plan and schedule for sediment removal and disposal.

END OF SECTION 8.00

SECTION 8.00 APPENDIX

The following text is derived from a technical paper by the North Carolina Department of Environmental Management. The content of the paper has been revised for this Appendix to more specifically address requirements of the Town of Smithfield.

SMITHFIELD.~ KORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 8.00 STORM DRAINAGE

Drawing SPEC8_5

Date 2/1/2000

Page 84: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

AN OVERVIEW OF WET DETENTION BASIN DESIGN

The design of wet detention basins is based on retaining the runoff from a storm for on extended length of time in order to settle out suspended solids and pollutants (such as heavy metals and nutrients). Biological treatment also occurs. Driscoll's model was chosen for the permanent pool water quality component of the design. The model uses as input a long-term overage storm statistically calculated from the historico rainfall record. By using this storm and the appropriate watershed characteristics (e.g., impervious cover), a permanent water quality pool is sized to detain the runoff long enough to attain the target total suspended solids (TSS) removal. The model incorporates settling that occurs during the storm (dynamic) and between storms (quiescent). The movement of the storm runoff through the basin is assumed to be via plug flow. In general, the Town requires 85% TSS removal in basins designed for the long-term overage piedmont storm. This may be achieved by detaining runoff from the first 1 -inch of rainfall for not less than two (2) days and not more than five (5) days.

In addition to the permanent water quality pool, the basin should hove a temporary water quality pool for extended detention. This temporary water quality storage, located above the permanent pool, is necessary for periods when runoff entering the basin is significantly warmer than the permanent water quality pool. DLlring tr.ese periods, a thermocline is established, plug flow does not occur and runoff exits the basin w;thout being detained long enough to achieve maximum settling. To counteract this lack of detention time and settling, the runoff (from the 1 inch storm) should be slowly released through a negatively sloped pipe.

Once the m1n1mum surface area and temporary storage volume of the basin needed to achieve the stated water quality goals are determined, the principal outlet and emergency spi!!woy may be sized for flood or erosion control. The storage allocated to flood control is located on top of both water quality oools, while the storage for erosion control occupies the same storage as the temporcry water quality pool (Figure 1 ).

The wetted perimeter of the basin should be planted with aquatic vegetation. This vegetation not only enhances pollutant removal but provides wildlife and waterfowl habitat, and protects the shoreline from erosion.

The Basins should be sized for the entire contributing area including offsite drainage. In general, instream impoundments should not De installed in order to ovoid sizing the storage for the entire upstream watershed. If a development encompasses the entire upper port of a drainage area, then locating the basin in the streombed will not increase the required storage. If the development hos offsite drainage flowing onto the site several basins may be utilized and sized for smaller drainage areas.

n addition to being properly designed, maintained to satisfy long-term water program is the allocation of adequate responsible party.

the basin must also be routinely quality goals. A key to any maintenance funding and the designation of the

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL A.~ SPECIFICATIONS MANUAL

SECTION 8.00 STORM DRAINAGE

Drawing SPEC8_6

Dote

2/1/2000

Page 85: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

SURFACE AREA TO DRAINAGE AREA RATIO (SA/DA) FOR PERMANENT POOL SIZING FOR 85% POLLUTANT REMOVAL EFFICIENCY

TABLE 1

Impervious

Using the Chart

% 3.0 3.5 4.0 4.5 5.0 5.5 6.0

10 0.59 0.54 0.49 0.47 0.43 0.39 0.35 20 0.97 0.88 0.79 0.75 0.70 0.65 0.59 30 1.34 1.20 1.08 1.03 0.97 0.91 0.85 40 1.73 1.58 1.43 1.36 1.25 1.14 1.03 50 2.00 1.82 1.73 1.64 1.50 1.40 1.33 60 2.39 2.09 2.03 1.87 1.66 1 .56 1 .51 70 2.75 2.44 2.27 2.12 1.96 1.87 1.79

The numbers in the chart represent surface area (SA) to drainage area (DA) percentages. SA=the wet detention pond permanent pool surface area required for 85% pollutant removal. The chart is based on the amount of impervious cover as a percentage of the area draining to the pond and the depth of the permanent pool of the pond. Impervious percentages are in the left hand column of the chart and depths are given across the table from 3 feet to 6 feet in half foot increments.

To determine the required permanent pool size use the following steps:

: . Calculate the percent impervious cover of the site draining to the pond (amount of impervious area/total site area).

2. Determine the permanent pool depth (or select a depth for comparison purposes).

3. Go to the above chart with the impervious percentage found in 1. Go across the chart at this impervious percentage until you are under the appropriate permanent pool depth and read the value in the table. The number in the chart is given as a percent (%). If your impervious percentage or pond depth is between one of the values given you can interpolate between values.

4. To determine the required surface area of the pond take the number from the chart, divide by 100 and multiply this number by the contributing drainage area.

For example: assume a 10 acre site with 3 acres of impervious cover.

1 . % impervious = 3/10 .30 or 30%

2. Assume a 4 foot permanent pool depth

3. From the chart, with 30% impervious and 4 foot depth, the SA/DA ratio is given as 1.08.

SMITHFIELD~ 1

NORTH CAROLINA ~ STANDARD DETAil, AND

SPECffiCATIONS MANUAL

SECTION 8.00 STORM DRAINAGE

Drawing SPEC8_7

Date 2/1/2000

Page 86: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

4. So the required surface area of the permanent pool is: (1.08/100) * 10 = .1 08 acres or 4,705 square feet.

5. The design runoff volume to be controlled must then be held in the pond above this permanent pool level.

DESIGN OF PERMANENT POOL DETENTION BASINS

A A Design For Water Quality Control

o) For the permanent water quality pool, use basin surface area/drainage area (SA/DA) ratios for given levels of impervious cover and basin depths (Tobie 1 ).

b) Average permanent water quality pool depths should be between 3 and 6 feet.

c) Use impervious levels expected in the final stages of development. d) Locate the temporary water quality pool for extended detention above

the permanent water quality pool. The orifice of the negatively sloped pipe should be sized to release runoff from the first 1 -inch rainfall over a period between 48 to 1 20 hours.

e) Basin shape should minimize dead storage areas: average length of flow to effective width > 2.0.

f) A forebay (may be established by a weir) should be included to encourage early settling. This allows drainage of only a portion of the basin in order to excavate accumulated sediment. The foreboy volume should equal about 20% the basin volume (Figure 2).

g) Check area ratios to make sure that the watershed will support a wet basin on existing soils.

h) If the basin is used as a sediment trap during construction, make sure that all sediment deposited during construction is removed before normal operation begins.

i) Aquatic vegetation should be included for a wetland type detention basin. A minimum 10 foot wide, one foot deep shelf is required around the edge of the basin for safety and to provide appropriate conditions for aquatic vegetation establishment. This shelf should be sloped 6: 1 or flatter and extend out to a point 2 to 2.5 feet below the surface. A list of suitable wetland species and propagation techniques ore provided in Schueler ( 1987) and Maryland DNR ( 1987). An emergency drain (with a pipe sized to drain the pond in less than 24 hours) should be installed in all ponds to allow access for riser repairs and sediment removal.

B. Design For Water Quantity

a) Design Storm

1) The primary outlet will most likely be designed for a 10-year storm. SCS suggests using the 24-hour storm.

2) The emergency spillway should be designed for the 100-yr storm. The Dom Safety Act gives guidance on design storms for spillways in larger asins.

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 8.00 STORM DRAINAGE

Drawing SPEC8_8

Date

2/1/2000

Page 87: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

Note that storms of other durations should be checked for overtopping.

b) Peak Runoff Flow

1) Use the SCS method, or 2) Use the Rational method, especially for watersheds less than 25

acres.

*Note: Care should be token with either method to accurately calculate the Curve Number or Rational C. **If the SCS method for calculating the runoff produces less than 0.5 inches of runoff, an alternate method for calculating runoff shall be used.

c) Volume of Runoff, Hydrograph Shape and Storage Required

1) Follow procedures in Malcom, et al., 1986, pp. 61-65, or 2) Use SCS methods. 3) Be sure to include o sediment storage pool in addition to the water

quality and flood pools. Unfortunately there is only limited data on sediment yields from urban areas. A method outlined in Schueler (1987, pp. 1.9 1.20) may be used for predicting those sediment yields. See example 1 -2 on page 2.19. In Piedmont areas, (P) 42 inches per year and (Pj) 0.9 (estimated). This calculation is for stabilized areas. The designer should keep in mind that this average sediment yield is at best an estimate of the actual sediment yield which is extremely dependent on such factors as soil type, slope and vegetative and stabilization practices. The designer would be prudent to overestimate sediment yield since more conservative (i.e., higher) sediment yield estimates will result in a larger allocated sediment storage and less frequent clean outs.

d) Stage-Storage Function for Basin

See Malcom and New, 1 pp. 106-109.

e) Stage Discharge

1) See appropriate equations for outflow structures and when each equation is the limiting factor (Barfield, et al., 1981, pp. 227 Malcom and New, 1975, pp. 3-9 to 3-11 ), or

2) Use methods in Land Quality's Sediment Basin handout (NCDNRCD, land quality, 12/86, pg.5).

f) Emergency Spillway and Dom Height

1)

2)

3)

Use SCS methods for emergency spillway design (Engineering Field Manual, USDA, SCS, 1986, Chapter 11; NCDNRCD, Land Quality, 12/86). Include calculation for wave height and wind setup for a detailed freeboord analysis (Lindsley and Franzini, 1972, pp. 179-183). Dams 15 feet or higher with on impoundment capacity of 10-ocre­feet or greater at the top of the dam must obtain a Dam Safety permit from NCDNRCD, Land Quality.

SMITHFIELD~ HORTH CAROLIRA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 8.00 STORM DRAINAGE

Drawing SPEC8_9

Date 2/1/2000

Page 88: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

g) Storm Routing

1) Use either Storage Indication Method (Viessman, et al., 1977, pg. 240-244; Mo 1com and New, 1975, pp. 113-115; USDA, SCS, Notional Engineering Honobook, Sec. 4, Chapter 17), or

2) Use HRM (H.R. Malcom) method of routing which is easy to execute and approximates the Storage-Indication Method (Malcom ond New, 1975, pp. 3-2 to 3-6, 110-113), or

3) Use SCS TR-20 method of routing. 4) The TR-55 routing method may be used for preliminary design

(USDA, SCS, 1986, TR-55, pp. 7-6 to 7-13).

h) Downstream Protection

1) As required in the Sedimentation Control Pion (NCDNRCD, 8/1/85, Title 15, NCAC 4B.0009). The post-construction velocity of the 1 0-year storm runoff shall not exceed the greater of: a) the mox;mum permissible velocity for the given channel iining, b) the 10-year pre-development velocity.

2) Use methods in N.C. Division of Land Quality's Energy Dissipater handout (no date).

3) As ment:oned in A(c) above, release the runoff from the first one-inch of rainfall over a 48 hour period for temporary water quality controi. McCuen and Moglen's research (1987) as well as research reviewed by Schueler ( 1987) suggest that smaller storms ore the key to controlling downstream streombonk erosion. Schueler (1987) suggests that runoff from the first one-inch of rainfall released over 24-40 hours can reduce aownstreom erosion. Therefore the design and storage pool for erosion control shall be the some as that for the temporary water quality pool.

i) Construction of Basin and Dom

1) See SCS Technical Guideline #378-1, Ponds. 2) See guidelines in Dom Safety Act (NCDNRCD, 11 /1/85) and SCS

handbook (USDA, SCS, 1986, Chapters 11 and 17). 3) See estimated construction costs from the NURP project in

Washington, D. C. (Metropolitan Washington COG, 1983, Chapter 3).

j) Other Design Considerations

') To ovoid clogging, barrels should be no smaller than 6 inches, risers no smaller than 8 inches, and reinforced concrete/concrete block structures no smaller than 24 x 24 inches (USDA, SCS, 1986, pg. 11-16).

2) An ontivortex structure should be included (Florido DNR, 1984 draft, pg. 6-282.)

3) The borrei should be anchored to avoid flotation (Florido DER, 1984 Draft, pg. 6-282).

4) Facilities with o large amount of oil and grease should use on oil and grease skimmer.

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 8.00 STORM DRAINAGE

Drawing SPEC8_10

Dote

2/1/2000

Page 89: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

5) Stormwater shou d be routed via grassed waterways or pipes to the upper part of the basin to reduce short circuiting and obtain maximum detention time and settling.

C. Operation and Maintenance

Ooeration and maintenance shali be the respons:bility of the developer or succeeding party in interest.

The Town reserves the right to perform periodic inspections of the Stormwater Control devices and may require maintenance to De performed if such a device or is fur,ctioning improperly.

D. Location

a) In order to avoid sizing the basin for the entire upstream drainage area, basins should be located out of the stream bed and sized for smol er subbasins in the development. Particu or core should be taken to modify storm drainage so that all developed areas drain to the basin ly if the site is intensively developed (e.g., condominium or commercial). This method will assure that all runoff from impervious areas wili be treated, without the necessity of retreating upstream runoff.

b) In r:ew y developing areas of the watershed, a regional detention basin may be on option for the local government and developers to consider. Compensation and joint maintenance contracts between upstream and downstream property owners would probably be necessary.

c) Buf~ers around the basin shou d be determined by the flood pool (usual y the 100-yeor storm).

E. Certification

All basins should be by a N. C.

stamped, and certified that tr.ey are built as professional engineer.

Use the 1986 revised SCS TR-55.

F. Definitions

1) Foreboy - The forebay is on excavated settling basin or a section separated by a low weir at the head of the primary impoundment. The foreboy serves as a depository for a large portion of sediment and facilitates draining and excavating the basin.

Plug flow Fluid particles which poss through the basin and are discharged in the some sequence in which they enter. The particles remain in the tank for a time equal to the theoretical detention time. This type of flow :s especially appropriate for basins with high length-to-width ratios.

3) Primary outlet The primary outlet is often constructed of a riser /barrel assembly and prov1aes flood protection (i.e., for the 10-yeor storm) or reduces the frequency af the operation of the emergency spillway.

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 8.00 STORM DRAINAGE:

Drawing

SPEC8_ 11

Date

2/1/2000

Page 90: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

4)

5)

spillway The emergency spillway is designed to discharge flow in excess of the principal spillway design (i.e., safely pass the 1 00-year storm).

Impervious surface Surfaces providing negligible infiltration such as pavement, buildings, recreation facilities, etc.

SMITHFIELD NORTH CAROLINA

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 8.00 STORM DRAINAGE

Drawing SPEC8_12

Date 2/1/2000

Page 91: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

1-43"MIN.

43"MIN.

CONCRETE SLAB

::E .1111 ;,-, t')

~rn °a: I ~'"i pal .... ~(/) (")i a-i

S:§ 9 ::ct-I CL (")§ = 00 •

g3. ~ n ~ti ~~ >11-1,j :~ i~ ~ .... I -H- 4"

PLAN

~~ ~~ i5 I -o 00 ~ 0 ~ -....j co -· * ';::;- oi 0 0 0

-1

I .8"

STD. MANHOLE RING AND COVER (PER DETAIL 7.06) MAY BE CAST IN SLAB OR SECURED TO TOP

i 8"~\_

w COURSE _, m <(

c2 <( >

NOTES:

EITHER SOLID BRICK , SOLID OR PRECAST CONCRETE USED.

STANDARD STEPS REQUIRED @ 16" O.C. WHERE DEPTH EXCEEDS 3'

USE MIN. 3000 P.S.I. CONC. MIX

INSIDE DIMENSION FOR 24" PIPE AND GREATER USE PIPE DIA. PLUS 12".

CONCRETE SLAB DESIGNED FOR EXPECTED LOADING

SECTION "-3000 PSI CONCRETE

Page 92: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

00 -~ ::;, "000 =rl §:~ ~~ "' G)g 9 t-91-1 s.~ ~~ :z: 1-i roo_ :l = gi ~~ ~ a.3.. oo'"'l ~ '1- ~> "' c;~ Fl 0 1-1 g~ ~> t-1~

~el ..... =t-t '=' 0 0 Cl -'-.J ro 0

"'- a,

N 0 0 N 0 0

NCDOT STANDARD 2'X2' GRATE

J \ ~ ~ , - _.·-·111-111-,_11_1-, 1-,.!._!_l_n ,·;a· 111_ ........... ril•r•111•n•[II.1£• :i1 I~ _j·· 8"

MORTAR ~~:Jilil ... ,..ill .· L_~O~PE~N~IN;;--G----~-·T·_·_, BED ·.

I 26"x26"

I. ' • b

'

P.S.I.

CORBEL BRICK

" PER COURSE

FOR 6 COURSE ---------"-,-

. "" ~ . .- ... : ..... < " ..

.•. ~ .:.. ·: .. ', .· '.i ~ •· ~­

-~-'b' ·•4·'~· .. .... .

SECTION

. ... . . .. . .. .

a

1./) w I.I)

<Ol!s 0 0

~I <(

er J1

:0

NOTES:

~ 1 ·I . . 1 , • -~ - • ,- ., "!' • l ~- ·: .1..

ro

:I 1.;U[ 1 ~ ! I

I i i

1x)

~

EITHER SOLID BRICK, SOLID BLOCK OR PRECAST CONCRETE MAY BE USED.

FOR 24" PLUS 12" FOR

GRATED INLETS SHALL NOT BE USED TRAVEL AREAS,

35" MIN.

PLAN

STANDARD STEPS REQUIRED @ 16" O.C. WHERE DEPTH EXCEEDS 3'.

8" ··~ -· ·--~,

I I •

i l ,,,,, 1 6 I I ~

i ! I lf=9~

r_.: '.· ,..,. ,, .... ,. ..

Page 93: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

coo ~.o () :::, "() -, () (I)

0 (D o~ ::, ~

0 OJ 0 QA (I) -·O ::J -,

"-. ~ ~ ,-+

co

er., "1:11:ll

§i 8~ ""'i:::, ot"i ~>-l

~t ~I:,

0 -, oo OJ ~-0:::, vl\Q )>

SHALLOW TYPE (5 FEET OR LESS IN DEPTH)

STANDARD STEPS 16" ON CENTER

6" --r- ,. -'I-ALTERNATE LAYING I DIRECTION EVERY

THIRD COURSE

.11.1 =IC ~ .... :ca-I

~=1 ~ .... t:~ =t-1 .., (0

8"-1-1--l-

1

INTERMEDIATE TYPE (4'X4') (5 FEET TO 20 FEET IN DEPTH)

ON

8"---1-'--1--

6"

1

SLAB DETAIL

NOTES:

REINFORCED CONCRETE SLAB

ALTERNATE LAYING DIRECTION EVERY THIRD COURSE

GRATE, & HOOD STD 840.03C

SLAB THICKNESS AND REINFORCEMENT FOR SOIL AND TRAFFIC LOADING BY AN ENGINEER

OVER 8' IN DEPTH, 12" WALL THICKNESS TO 6' FROM TOP OF WALL AND 8" BOTTOM SLAB SHALL BE USED.

STANDARD STEPS 1 6" ON CENTER

REINFORCED CONCRETE

DEEP TYPE (5'X5') (OVER 20 FEET IN DEPTH)

SLAB! 8" ~-' 60" .- . •~

6' MIN.

J;, +-. 8"

I SLAB DETAIL

AND r· FOR SOIL AND TRAFFIC LOADING BY AN ENGINEER 76"

L f

76"

8"

Page 94: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

"O "'"I

(;~ Q Q ,...ti) () ,.,. ::r

(; CD O Q::, ti) ()

s·~ lD"

~CJ

s. (1)

00

~~

~~ ~§ Ot::i ~i'."i 00 >-3

it

0 .., oo OJ :§. 0 ::::, w-lLO CD

=z:"'2 c EC ~ .... tel-ii ~= ~~ 01-1 t:~ f::t-1

'=:I

«)

l_ 6"

I

SHALLOW TYPE (5 FEET OR LESS IN DEPTH)

MIN. 6" WASHED STONE BEDDING

FRAME, GRATE, & HOOD PER D.O.T. STD. 840.03C

NOTES: 1 CONRETE SHALL BE 4000 PSI MIN. FOR All

PRECAST CONCRETE CATCH BASINS. 2. PRECAST CONCRETE STRUCTURES MAY ONLY

BE INSTALLED TO DEPTHS CERTIFIED AS ACCEPTABLE BY THE MANUFACTURER

3. "WAFFLE" BOXES ARE ACCEPTABLE FOR SHALLOW TYPE CATCH BASINS.

INTERMEDIATE TYPE (4'X4')

(5 FEET TO 20 FEET IN DEPTH)

STANDARD STEPS

DEEP TYPE (5'X5')

(OVER 20 FEET IN DEPTH)

~~ AA>•An~~ I 16" ON CENTER SLAB

0

5'! MIN.

l_ 6"

\_ MIN. 6" WASHED STONE BEDDING

,.,,--FRAME, GRATE, / PER D.O.T. STD.

20'

MIN. 6" WASHED STONE BEDDING

SLAB DETAIL

ti"~ r~e" I 60" I

SLAB THICKNESS AND REINFORCEMENT FOR SOIL AND TRAFFIC LOADING BY AN ENGINEER

6"

t

~~M~'.oGT~1Th.

5"

I

SLAB THICKNESS AND REINFORC[MENT FOR SOIL AND TRAFFIC LOADING BY AN ENGINEER

-:-::-

MIN. 6" WASHED STONE BEDDING

SLAB DETAIL

6"

72"

l [ 72"

Page 95: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

mm N~ ~o

·c-,i 01.[) ~lX}

oci ZI­< (/) < 1-~ o ~o ·u

~z row

.w 0(/) 1-(/) (/)

1-z OQ 0(/) uz z~ Io 1-3: o z w::5 ~~ O'.'.:D.'.'. 00 u...LL

Q)

co

I :J: 0 . I ~ z .</' 2

0

~ F u w (/)

ro~

a:: ~ = a,

I = 0 I~ w2

_L

um I.[)~ ~o

0 . zR < (/) ITil­"S/" O ~o ·u

~z lX} w .w

0 (/) 1-(/) (/)

1-Z oQ 0 (/) uz zW

:z i:: 0 3: 0

z iii ::5 ::)~

D.'.'.O'.'. oo LL LL

(D OJ

I z 0 F u w (/)

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

Standard Median Curb Inlet

Drawing 0804A

Date 1/17/2000

Page 96: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

~ um

I LI)~ ~O

•c--.i oll)

N ~a:)

~ oc:i ZI-<t: (/)

m1--stO

LJ.. ~o I m ·u

LJ.. m ~z :

COW 0 I ?'. .w

-<.D 2 z 0(/) I-

t 0 (/) (/)

_L i== 1-z u w o9 (/) Q(/)

uz zW

2 :r:o I-

0) ~o z

w:5 U) (/) ::J_

il'.'.O::: 00

n LJ..LJ..

0::: w

_j> <t:o 0::0 Wu, ~(/)

2~ :r:(!) 1-:i: fr'. I-

iS~

I-z 0 -:,

z Q (/) z <t: (l_

X w

N

" 0::: w ~ ::J 0

~

ro a:: ::J 0

SMITHFIELD~ NORTH CAROLINA ~

STA]'l('DARD DETAIL AND SPECIFICATIONS MANUAL

Standard Median Curb Inlet

Drawing 0804B

Dote 1/17/2000

Page 97: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

CD

t LL I (D

ci (J) ~

!

,u.. CD 0 . I ~

tD 2 z 0

t i== u w (J)

"

~-

n

om l[) ~

0 oN v LO o:J o:J 0 . zo <( ~ (D I-vO

0 ·u ~z (X) w .w

0 (J) I-(/) (J)

I- z oQ 0 (/) uz zW

2 I-I- 0 §: 0

z iii :5 ::) '!:? O'.'. a:: 00 lL lL

O'.'. w

_j> <to _() a:: WU)

~(/)

2~ ICJ 1-:r: Cl'.'. I­<( -w:s:

z 0 U)

z ii X w

SMITHFIELD~ HORTH CAROLINA ~

STAI\'DARD DETAIL AND SPECIFICATIONS MANUAL

Standard Median Curb Inlet

Drawing 0804C

Date 1/17/2000

Page 98: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

r:,:, '"= r:,:,

;i::: ('j..., a n> 5-~ 3~ 2.o ni (l) g > <:,._rl- ....

§ o ot::i 0 0 :zt,,,l

§CS r :) i t= [lJ (1) ~

~ ~s

~lo OJ 0 (J1

.r,J ~a: a-!11-1 I a:t-i n::C =-~ '°11-1 ~tti '""' =t-1 t:,

0

STANDARD STEPS 1 6" ON CENTER

UP TO 20'

5"

BRICK AND MORTAR INVERT

12"

STANDARD TYPE TO 20 FEET IN

STANDARD MANHOLE RING AND COVER

TOP DESIGNED FOR HS-20 LOADING MAY BE FLAT OR ECCENTRIC CONE

PLASTIC CEMENT PUTTY OR BUTYL RUBBER JOINTS

MIN. 6" THICK WASHED STONE BEDDING

FLAT TOP DETAIL

58"

t

I

STANDARD STEPS 1 6" ON CENTER

OVER 20'

6"

BRICK AND MORTAR INVERT

12"

DEEP TYPE (OVER 20 FEET IN

STANDARD MANHOLE RING AND COVER

TOP DESIGN FOR HS-20 LOADING MAY BE FLAT OR ECCENTRIC CONE

Lj-- PLASTIC CEMENT PUTT OR BUTYL RUBBER JOINTS

6"

MIN. 6" THICK WASHED STONE BEDDING

FLAT TOP DETAIL

~ t 70"

Page 99: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

:;;: O::'. 0 I-n:: (/J

L7Jo >-o o:3 ~ LL

[> 11

Icl<'.'. (/Ju ~<( I- O::'.

:;;: a::: 0 I-(/J

I u ~

[> 11

:?i <( 0

z 0 i=

I- ;3; Zw W-1 zw <( :::,:-1 0'.'.0 WO Q_ Q_

11

\ a:::: Oz LL3:

~~ a::: wo

>1-(/) (/J

00'.'. 0::: <( WW J>-Oo z~

:::ii a::: 0 I-V)

wO I uO U t;~ z O::'.O::'. u... 000

I

w Q_

Q_

z <( 0::: 0

>­u z w (.'.) O::'. w ~ w

SMITHFIELD ~ KORTH CAROLIKA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

Wet Detention Bosion

Drawing Figure-1

Date 1/18/2000

Page 100: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

CD ::iE Q (1) U) ,.+

:i' 0

0~ (1) (1)

~-~ '° -· ::, Q ::,

17.l ~Cl)

~~ Se 8~ 61:1 zl"'l r:,i"'-l

~~ ~~

.111 =a: = .... ml-I n::C >"" ,., .... f3M =t-' t:,

-'O 0 ':::-~ ::r19 (1) '° Q c:: :::;

~ ~- * I

rv

INLET

SAFETY BENCli (10 FEET

-----~

WEDGE-SHAPED PERMANENT POOL

TOP VIEW

NEGATIVE SLOPE DRAIN -

STORMWATER STORAGE

PERMANENT POOL

SEDIMENT FOREBAY (PLANTED AS

REQUIRED DESIGN UNLESS SIDE VIEW OTHERWISE APPROVED BY TOWN COUNCIL

EMBANKMENT

-~

EMERGENCY SPHWAY

EMBANKMENT

Page 101: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

(lJ D [/)

s·o (l)

•-(1) (1)

[/) 3-<0' o· ::, ::,

i:n

~i:n

n~ Se

H i~ ~~

. ..,.,. =I: ~ .... ma-I n::C: >IIP.I ~ .... t:~ :ft-I t::,

~a 0 ':::;-s_=i~_ CTl cO 0

C ~ ' -· "' ::, 1'° ,.. (,<

STABILIZED INLET

(RIPRAP)

~ -----------------------

2% MINIMUM SLOPE TOPSTAGE \ --------

~ c? & ~

& # ~

TOP VIEW

f 'if ~ SIDE SLOPES - BOTTOM STAGE

3 : 1 MAX

INFLOW r DESIGN SURFACE ELEVATION \

__ TOP STAGE (NORMALLY_\

/ 2% OR GREATER SLOPE FOR DRAINAGE

MAINTAINED GRASS BOTTOM & SIDE SLOPES SIDE VIEW

SHALLOW MARSH DESIGN (6" - 17"

_ __j_

~-

10 : 1 MIN

REQUIRED DESIGN UNLESS OTHERWISE APPROVED BY TOWN COUNCIL

BOTTOM STAGE DESIGNED TO ACCEPT REQUIRED RUN-OFF VOLUME

EMERGENCY SPILLWAY

STABILIZED

MINIMUM ONE FOOT FREEBOARD ABOVE EMERGENCY SPILLWAY

\

PERFORATED RISER ENCASED IN GRAVEL JACKET

Page 102: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

SECTION 9.00 'AS-BUil T' DRAWING REQUIREMENTS

All entities who construct public waterlines or facilities, p0blic sewer lines or facilities, or public streets to be maintained by the Town of Smithfield shal 1

submit to the Town of Smithfield Construction Management Deportment an cs-built set of construction drawings as a port of the Town's acceptance process. All plan sheets shall be 24" x 36" mylar. Lettering shall be bold, clear, and a minimum of 1 /8" in height. All applicable listed below shall be included on all as-built drawings.

9.01 SITE DATA

A. Acreage in total tract 8. Average lot size C. Total number of lots D. Total linear footage and size of streets, water mains, sewer mains, number

number of valves, fae hydrants and manholes.

9.02 GENERAL INFORMATION

A. Boundary of tract by courses and distance with references 8. Tie to N. C. grid coordinate system C. 500 scale vicinity mop D. Scale of drawings and bar scale E. North arrow F. Location of benchmark with M.S.L. elevations G. Seal and signature of North Carolina registered P. E. or R.L.S. H. All easements identified and dimensioned. I. Statement designating drawings are "as-built".

9.03 STREETS (Public or Private)

A. Horizontal alignment with radii, P.C.'s, and P.T.'s of all curves B. Vertical alignment with centerline grades, vertical curve lengt.,s, end station

and elevation of all PVC's and PVT's and centerline profile. C. Dimensioned right of way and street widths D. Pavement section

Typical cross section

9.04 STORM DRAINAGE

A. Outline of 100 year flood plain

B. Pipe material C. Structure invert and top elevations

D. Pipe size

E. Pipe slope and distance

F. Size of riprap dissipation pod

G. Statement of stormwater velocity at all outlets H. Show permanent stormwater impoundments. I. Include maintenance clause from covenants for stormwater impoundments.

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAJL AND SPECIFICATIONS MANUAL

SECTION 9 "AS-BUILT" DRAWING REQUIREMENTS

Drawing SPEC9_1

Date 2/1/00

Page 103: STANDARD DETAIL AND SPECIFICATIONS MANUAL · 2008. 9. 1. · section 1.00 definmons and abbreviations 1.01 definitions 1.02 abbreviations section 2.00 general provisions 2.01 ge ieral

9.05 WA TEA SYSTEM

A. Pipe material B. Pipe size C. Separation from sanitary and storm sewers D. Locations of valves, fire hydrants, meters, and blow-offs with distance

references E. Certification by N.C.P.E. of Construction in accordance with state issued

permits. In addition to certification on the plans, a separate certification sheet shall be provided.

F. A separate, recorded easement dedication form for public line extensions outside right of way.

9.06 SANITARY SEWER SYSTEM

A. Pipe material B. Pipe size C. Manhole top elevations D. Invert in and out elevations E. slope F. -out locations with distances referenced G. Horizontal control (angles at manholes) H. 100-year flood plain elevation I. Certification by N.C.P.E. of Construction in accordance with state issued

. In addition to certification on the plans, a separate certification shall be provided.

J. recorded easement dedication form for public line extensions right of way.

END OF SECTION 9.00

SMITHFIELD~ NORTH CAROLINA ~

STANDARD DETAIL AND SPECIFICATIONS MANUAL

SECTION 9 "AS-BUILT" DRAWING REQUIREMENTS

Drawing SPEC9_2

Date 2/1/00