  • 1755 La Costa Meadows Drive | San Marcos, California 92078 USA760-744-6950 Toll Free (US): 800-854-1993 Fax: 760-736-6250www.fluidcomponents.com

    Order Information Sheet (OIS)

    ST98FlexMASSter Insertion Mass Flow Meter

    INSTRUCTIONS: To order an ST98, please fill in the numbered Block above with the appropriate Code from the categories below. See Ordering Guide on page 2 for ST98 High Temperature. Once you have determined all specifications, contact an FCI representative or FCI directly for price information or additional options not shown. Consult FCI on the cost of special data and documentation. Final acceptance of the part number is subject to FCIs approval.

    Special Instructions________________ ______________________________________________________ ______________________________________Block No. Code W or * Description

    ST98 -Block No. 1 2 3 4 5 6 7 8 9 10 11

    Optional Accessories 9

    Part # Description

    FC88 Portable Hand-Held Communicator

    014108-02 PC Interface Communication Kit

    Code [ BLOCK 1 ] Flow Direction1 Horizontal right to left, or vertical up2 Horizontal left to right, or vertical down

    Code [ BLOCK 2 ] Material of Construction 15

    FPC Style SensorE 316 stainless steel (to 350 F [177 C])G 316 stainless steel (to 500 F [260 C])F Hastelloy-C276 (to 350 F [177 C])H Hastelloy-C276 (to 500 F [260 C])

    FP Style Sensor3 316 stainless steel (to 350 F [177 C])7 316 stainless steel (to 500 F [260 C])4 Hastelloy-C276 (to 350F [177C])8 Hastelloy-C276 (to 500F [260C])

    S Style Sensor1 316 stainless steel (to 350 F [177 C])5 316 stainless steel (to 500 F [260 C])2 Hastelloy-C276 (to 350 F [177 C])6 Hastelloy-C276 (to 500 F [260 C])

    W Agency approved, customer specified* Other

    Code [ BLOCK 9 ] Interconnecting Cable0 Not required (customer supplied)

    PVC JacketA 10 [3 m]B 25 [7,6 m]C 50 [15 m]W Agency approved, customer specified 5

    Code [ BLOCK 10 ] Calibration 1: Application 6, 7, 8, 9, 10

    Standard CalibrationA Air: 1.25 SFPS to 125 SFPS; 10 psia to 65 psia; 40 F to 100 F

    [0,4 NMPS to 38 NMPS; 0,7 bar (a) to 3,5 bar (a); 4 C to 38 C]D Compressed air; 6 SFPS to 600 SFPS; 50 psia to 165 psia;

    40 F to 100 F [1,8 NMPS to 183 NMPS; 3,5 bar (a) to 11 bar (a); 4 C to 38 C]

    Custom CalibrationB AirC Air equivalency (digester gas, flue gas, etc.)E Nitrogen, helium, argon, carbon dioxide,

    compressed air, or digester gasF Hydrocarbons (natural gas, methane, ethane, propane, etc.)G Hydrogen or hydrogen mixtureW Agency approved, customer specified 8

    Code [ BLOCK 11 ] Calibration 2: Setup

    0 Standard 9

    A Temperature compensationC Vortab (VEL, VFK, VIS, VMR or VSR)1 Vortab (VIP)D Flat velocity profileF Temperature compensation and Vortab (VEL, VFK, VIS, VMR or VSR)2 Temperature compensation and Vortab (VIP)G Temperature compensation and flat velocity profile

    Code [ BLOCK 6 ] Insertion Length1 1 to 6 [25 mm to 152 mm]2 1 to 12 [25 mm to 305 mm]3 1 to 21 [25 mm to 533 mm]

    W Agency approved, customer specified Code [ BLOCK 7 ] Enclosure 4

    Integral ConfigurationsNonincendive for Class I, Div. 2, Groups A, B, C, D; Suitable for Class II, Div. 2, Groups F & G; Class III, Div. 2 (meets IP66)

    A Carbon steel, NEMA Type 41 Aluminum, NEMA Type 4X

    Class I, Division 1 hazardous locations: Groups B, C, D, E, F, G; ATEX/IECEx II2 GD Exd IIC

    B Aluminum, NEMA Type 4XRemote Transmitter Configurations

    Local aluminum enclosure: NEMA Type 4X (meets IP67) Class I, Div. 1, Groups B, C, D, E, F, G; ATEX/IECEx II2 GD Exd IIC

    Local RemoteC Aluminum Carbon steel, NEMA Type 4

    Approval per Code A2 Aluminum Aluminum, NEMA Type 4X

    Approval per Code 1D Aluminum Aluminum, NEMA Type 4,

    explosion-proof Approval per Code B

    E Aluminum None, panel mountW Agency approved, customer specified* Other

    Code [ BLOCK 8 ] Transmitter Option0 4-20 mA output, no displayA 4-20 mA output, with displayB HART protocol, 100 Vac to 240 Vac [50/60 Hz] 14 C HART protocol with display, 100 Vac to 240 Vac

    [50/60 Hz] 14 D HART protocol, 9 Vdc to 36 Vdc 14

    E HART protocol with display, 9 Vdc to 36 Vdc 14 F PROFIBUS DP Profile 3, no display 19 G PROFIBUS DP Profile 3, protocol with display 19

    W Agency approved, customer specified 3

    * Other

    Code 3 4 5

    [ BLOCKS 3-5 ] Process Connection

    Compression FittingTeflon Ferrule to 200 F [93 C], 150 psig [10 bar (g)]

    C T 0 3/4 inch male NPT retractable with S style sensor 18

    D N 0 1 inch male NPT retractable with FP / FPC style sensors 17

    G Flange 1, 17, 18 select Codes for Blocks 4-5 from Table A

    Metal Ferrule 2 to 500 F [260 C], 250 psig [17 bar (g)]M T 0 3/4 inch male NPT 18

    N N 0 1 inch male NPT 17

    J Flange 1, 17, 18 select Codes for Blocks 4-5 from Table A

    (continued next column)

    Code 3 4 5

    [ BLOCKS 3-5 ] Process Connection (continued)

    Retractable Packing Gland with Graphite Packing Material 16

    Low Pressure to 50 psig [3,5 bar (g)]P A 0 1-1/4 inch male NPTQ Flange

    13 select Codes for Blocks 4-5 from Table A

    Medium Pressure to 250 psig [17 bar (g)] 12

    R A 0 1-1/4 inch male NPTT Flange

    13 select Codes for Blocks 4-5 from Table AW W W Agency approved, customer specified

    * * * Other

    g For ST98 High Temperature (850 F [454 C]), see page 2 Ordering Guide

    Table A

    Code [ BLOCK 4 ] Flange or NPT Size

    Male NPTT 3/4 inch (compression fitting)N 1 inch (compression fitting)A 1-1/4 inch (packing gland)

    Raised Face Flange1 ANSI 1 inchB ANSI 1-1/2 inch2 ANSI 2 inchE DIN DN 25G DIN DN 40J DIN DN 50W Agency approved, customer specified 1

    Code [ BLOCK 5 ] Raised Face Flange Rating / Material0 For male NPT onlyG 150 lb material per Block 2A 150 lb carbon steelH 300 lb material per Block 2B 300 lb carbon steel2 DIN PN16 in 316L stainless steel3 DIN PN40 in 316L stainless steel

    W Agency approved, customer specified 1

    Copyright 2010 Fluid Components International LLC. All rights reserved. Subject to change without notice. Order Information Sheet effective 01/2013 Doc. No. 01SA011441 W Page 1 of 2

    Notes

    * Voids Agency Approvals. Contact FCI.1. Flange is tapped and threaded for the 3/4 inch compression fitting. All

    ANSI flanges are raised face phonographic serrated, all DIN flanges are Form C.

    2. Material matches selection in Block 2. Metal ferrule permanently locks after tightening compression fitting.

    3. Maximum length is 60 inches [1524 mm].4. Enclosure required for agency approvals.

    Notes (continued)5. Overall shielded conductors required and wire resistance must

    be less than 8 Ohms.6. Turndown ratio is 10:1 minimum and 100:1 maximum.7. FCI Standard Conditions are 14.7 psia [1,01 bar(a)] and 70 F [21,1 C].8. Customer specified calibration must not exceed temperature

    and pressure limitations of the ST98 product specifications.9. Transmitter setup, changes to factory supplied standard

    settings, verification or modification to calibration parameters or diagnostics requires external source communication with the transmitter. Via RS232 port use Model FC88 communicator or PC with PC interface kit or via HART bus (if selected) or when PROFIBUS is selected, then must be performed via PROFIBUS link.

    10. Calibration codes must be selected using FCIs proprietary AVAL application evaluation software.

    12. Remote electronics is required.13. The minimum flange size is 1-1/2 inches or DN40.14. Isolated output and selectable passive or active output is a

    standard feature with HART protocol. Flow range with HART protocol must be 0 based.

    15. T4 rated at 104 F [40 C].16. Teflon packing material must be ordered when the process

    media is Ozone, Chlorine or Bromine (consult factory).17. FP / FPC style sensors require 0.88 inch diameter minimum

    clearance hole through process connection.18. S style sensor requires 0.81 inch diameter minimum

    clearance hole through process connection.19. No mA output or RS232 available with PROFIBUS.

  • 1755 La Costa Meadows Drive | San Marcos, California 92078 USA760-744-6950 Toll Free (US): 800-854-1993 Fax: 760-736-6250www.fluidcomponents.com

    Order Information Sheet (OIS)

    ST98FlexMASSter Insertion Mass Flow Meter

    INSTRUCTIONS: To order an ST98 HT, please fill in the numbered Block above with the appropriate Code from the categories below. Once you have determined all specifications, contact an FCI representative or FCI directly for price information or additional options not shown. Consult FCI on the cost of special data and documentation. Final acceptance of the part number is subject to FCIs approval.

    ST98 HT- .Block No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14

    Copyright 2010 Fluid Components International LLC. All rights reserved. Subject to change without notice. Order Information Sheet effective 01/2013 Doc. No. 01SA011441 W Page 2 of 2

    Code [ BLOCK 1 ] Flow Direction1 Horizontal right to left, or vertical up2 Horizontal left to right, or vertical down

    Code [ BLOCK 2 ] Material of Construction 15

    FPC Style Sensor (to 850 F [454 C]) 12

    J 316 stainless steelK Hastelloy-C276

    FP Style Sensor (to 850 F [454 C]) 12

    A 316 stainless steelB Hastelloy-C276

    S Style Sensor (to 850 F [454 C]) 12

    C 316 stainless steelD Hastelloy-C276W Agency approved, customer specified* Other

    Code [ BLOCK 10 ] Calibration 1: Application 6, 7, 8, 9, 10

    B AirC Air equivalency (digester gas, flue gas, etc.)E Nitrogen, helium, argon, carbon dioxide,

    compressed air, or digester gasF Hydrocarbons (natural gas, methane, ethane,

    propane, etc.)G Hydrogen or hydrogen mixtureW Agency approved, customer specified 8

    Code [ BLOCK 11 ] Calibration 2: SetupA Temperature compensation

    F Temperature compensation and Vortab (VEL, VFK, VIS, VMR or VSR)2 Temperature compensation and Vortab (VIP)

    G Temperature compensation and flat velocity profile

    Code [ BLOCK 9 ] Interconnecting Cable0 Not required (customer supplied) 5

    TeflonD 10 [3 m]E 25 [7,6 m]F 50 [15 m]

    W Agency approved, customer specified 5

    Code [ BLOCK 6 ] Insertion Length2 1 to 12 [25 mm to 305 mm]3 1 to 21 [25 mm to 533 mm]4 1 to 36 [25 mm to 914 mm]5 1 to 60 [25 mm to 1524 mm]A Fixed length; specify desired length in Blocks 12-14W Agency approved, customer specified 3

    Code [ BLOCK 7 ] Enclosure 4, 12, 20

    Remote Transmitter ConfigurationsLocal aluminum enclosure: NEMA Type 4X (meets IP67) Class I, Div. 1, Groups B, C, D, E, F, G; ATEX/IECEx II2 GD Exd IIC

    Local Remote

    C AluminumCarbon steel NEMA 4: Nonincendive for Class I, Div. 2, Groups A, B, C, D;Suitable for Class II, Div. 2, Groups F & G; Class III, Div. 2 (meets IP66)

    2 AluminumAluminum NEMA 4X: Nonincendive for Class I, Div. 2, Groups A, B, C, D;Suitable for Class II, Div. 2, Groups F & G; Class III, Div. 2 (meets IP66)

    D Aluminum Aluminum hazardous locations: Class I, Div. 1 hazardous locations; Groups B, C, D, E, F, G; ATEX/IECEx II2 GD Exd IIC

    E Aluminum None, panel mountW Agency approved, customer specified* Other

    Code 3 4 5

    [ BLOCKS 3-5 ] Process Connection

    For fixed insertion length, Block 6 must be Code A 17

    N N 0 1 inch male NPTJ Flange select Codes for Blocks 4-5 from Table A

    Retractable Packing Gland with Graphite Packing Material 16

    Low Pressure to 50 psig [3,5 bar (g)]P A 0 1-1/4 inch male NPTQ Flange

    13 select Codes for Blocks 4-5 from Table A

    Medium Pressure to 250 psig [17 bar (g)] 12

    R A 0 1-1/4 inch male NPTT Flange

    13 select Codes for Blocks 4-5 from Table AW W W Agency approved, customer specified 1

    * * * Other

    Table A

    Code [ BLOCK 4 ] Flange

    Raised Face FlangeB ANSI 1-1/2 inch2 ANSI 2 inchG DIN DN 40J DIN DN 50W Agency approved, customer specified 13

    Code [ BLOCK 5 ] Raised Face Flange Rating and Material

    G 150 lb material per Block 2

    A 150 lb carbon steel

    H 300 lb material per Block 2

    B 300 lb carbon steel

    2 DIN PN16 in 316L stainless steel

    3 DIN PN40 in 316L stainless steel

    W Agency approved, customer specified

    Notes

    * Voids Agency Approvals. Contact FCI.3. Maximum length is 60 inches [1524 mm].4. Enclosure required for agency approvals.5. Overall shielded conductors required and wire resistance

    must be less than 8 Ohms.6. Turndown ratio is 10:1 minimum and 100:1 maximum.7. FCI Standard Conditions are 14.7 psia [1,01 bar(a)] and 70 F

    [21,1 C].8. Customer specified calibration must not exceed temperature

    and pressure limitations of the ST98 product specifications.9. Transmitter setup, changes to factory supplied standard

    settings, verification or modification to calibration parameters or diagnostics requires external source communication with the transmitter. Via RS232 port use Model FC88 communicator or PC with PC interface kit or via HART bus (if selected) or when PROFIBUS is selected, then must be performed via PROFIBUS link.

    10. Calibration codes must be selected using FCIs proprietary AVAL application evaluation software.

    12. Remote electronics is required.13. The minimum flange size is 1-1/2 inches or DN40.14. Isolated output and selectable passive or active output is

    a standard feature with HART protocol. Flow range with HART protocol must be 0 based.

    15. T4 rated at 104 F [40 C].16. Teflon packing material must be ordered when the process

    media is Ozone, Chlorine or Bromine (consult factory).17. Sensor requires 1.10 inch diameter minimum clearance hole

    through process connection.20. Agency approvals for system are pending.

    Code [ BLOCK 8 ] Transmitter Option

    Power Supply

    Digital Display?

    HART Comm?

    K 100 Vac to 240 Vac No No (upgradable)

    B 100 Vac to 240 Vac No Yes 14

    L 100 Vac to 240 Vac Yes No (upgradable)C 100 Vac to 240 Vac Yes Yes 14

    H 22 Vdc to 30 Vdc No No (upgradable)D 9 Vdc to 30 Vdc No Yes 14

    J 22 Vdc to 30 Vdc Yes No (upgradable)E 9 Vdc to 30 Vdc Yes Yes 14

    W Agency approved, customer specified* Other

    Code [ BLOCKS 12-14 ] Insertion Length (Inches)0 0 0 If Block 6 Code is 2, 3, 4 or 5

    . If Block 6 is Code A, specify length in inches to 0.1 E.g. 08.5 is 8-1/2 inches. Minimum is 02.06, maximum is 60.0

    Optional Accessories 9, 11

    Part # Description

    FC88 Portable Hand-Held Communicator

    014108-02 PC Interface Communication Kit