St Joseph’s Catholic Academy - Extension
Structural Package
[S/110]
C[S/110]
C
[S/110]
B[S/110]
B
[S/110]
A[S/110]
A
[S/120]
1[S/120]
1
[S/110]
D[S/110]
D
[S/120]
2[S/120]
2
[S/120]
3[S/120]
3
[S/120]
4[S/120]
4
ANCON WP2130x70x6mm
ANCON WP2130x70x6mm
ANCON WP2130x70x6mm
ANCON WP2130x70x6mm
ANCON WP2130x70x6mm
ANCON WP2130x70x6mm
CATNIC TS90/100 LINTEL
CATNIC CG90/100 LINTEL
CA
TN
IC T
S90
/100
LIN
TE
LC
AT
NIC
TS
90/1
00 L
INT
EL
CA
TN
IC T
S90
/100
LIN
TE
LC
AT
NIC
TS
90/1
00 L
INT
EL
CATNIC TS90/100 LINTEL
CATNIC TS90/100 LINTEL
CA
TN
IC C
G90
/100
LIN
TE
L
FOOTING600
FOOTING600
FOO
TIN
G
600
FOO
TIN
G
600
FOO
TIN
G
600
600 WIDE STRIP FOOTING TO ALL NEW WALLS
FOOTING600
600 WIDE STRIP FOOTING TO ALL NEW WALLS
FOOTING600
[S/1
20]
5[S
/120
]
5
CA
TN
IC C
G70
/100
LIN
TE
L
6S/120
CATNIC BSD140 LINTEL
CATNIC CG70/100 LINTELTBC ON SITE TO SUIT EXISTING WALL THICKNESS
INFILL EXISTING DOORWAY.PROVIDE WALL STARTERS PLUGGED & SCREWED INTO THE EXISTING MASONRY WALL, OR TOOTH CUT & BOND NEW WALL IN
FOOTING600
EXISTING SLAB TBC400 FOOTING TO SUIT
150mm THK RC35 GROUND BEARING SLAB A252 MESH IN BOTTOM
150mm THK RC35 GROUND BEARING SLAB A252 MESH IN BOTTOM
150mm THK RC35 GROUND BEARING SLAB A252 MESH IN BOTTOM
150mm THK RC35 GROUND BEARING SLAB A252 MESH IN BOTTOM
FOO
TIN
G
600
20 mm DOWELLED SLAB
JOINT, 16 mm⌀
600 mm LONG DOWEL BARS @ 200 C/C
EXISTING RAFT / SLAB TO BE RETAINED - LEVEL TO BE CONFIRMED ON SITE
EDGE OF EXISTING RAFT / SLAB TO BE CUT BACK TO ALLOW FOR PROPOSED MASONRY WALL - REFER TO SECTION DETAILS.EXPOSED FACE MADE GOOD WITH CEMENTITIOUS REPAIR PRODUCT SUCH AS FOSROC RENDEROC OR SIMILAR APPROVED.
PROVIDE WALL STARTERS PLUGGED & SCREWED INTO THE EXISTING MASONRY WALL.DENOTED THROUGHOUT WITH RED LINE.
NEW WALLS GENERALLY 100 BRICK, 100 CAVITY, 100 BLOCK - 7N/mm2
BLOCKWORK IN CLASS (iii) MORTAR -MINIMUM DENSITY 1400Kg/m2
IN THE ABSENCE OF A SITE INVESTIGATION REPORT A GROUND BEARING SLAB HAS BEEN ADOPTED.
SI TO CONFIRM WHETHER ANY GROUND GAS PRECAUTION
MEASURES ARE NEEDED AND DETAILS REVISED AS REQUIRED.
600 WIDE STRIP FOOTING TO ALL NEW WALLS.INTERFACE WITH EXISTING FOUNDATIONS / RAFT /
SLAB TBC FOLLOWING SITE EXCAVATION.
140 mm 7N BLOCKWORK WALL TIED TO EXISTING WALL WITH SCREW CAVITY TIES
MAX
110
0M
AX 1
100
MAX
110
0M
AX 1
100
MAX
110
0M
AX 1
100
MAX
110
0M
AX 1
100
MAX
110
0M
AX 1
100
FOUNDATION UNDERPINNING EXISTING SLAB TO BE POURED IN
MAX 1100 mm LONG SECTIONS.AN ALTERNATING SEQUENCE MAY
BE ADOPTED - TO BE AGREED WITH THE ENGINEER
WALL MOVEMENT JOINT
WALL MOVEMENT JOINT
CA
TN
IC T
S90
/100
LIN
TE
L
WALL MOVEMENT JOINT
[S/110]
C[S/110]
C
[S/110]
B[S/110]
B
[S/110]
A[S/110]
A
[S/110]
D[S/110]
D
MULTI-PLY EASI-JOIST GIRDER -AS REQUIRED BY SPECIALIST DESIGNER
TO SUPPORT TOILETS ROOF.
EASI-JOISTS BUILT INTO MASONRY WALL OR SUPPORTED FROM MASONRY
HANGERS - TO MANUFACTURERS DESIGN
PROPOSED WS300 EASI-JOISTS DESIGNED BY SPECIALIST AT 400 HORIZONTAL CENTRES OR SIMILAR APPROVED
PROPOSED WS300 EASI-JOISTS DESIGNED BY SPECIALIST AT 600 HORIZONTAL
CENTRES OR SIMILAR APPROVED
EXISTING CANOPY - UNDERSTOOD TO BE RETAINED TO FORM ROOF
TO BREAKOUT ROOM
EXISTING SCHOOL ROOFS RETAINED
ANCON WP2130x70x6mm
ANCON WP2130x70x6mm
ANCON WP2130x70x6mm
ANCON WP2130x70x6mm
ANCON WP2130x70x6mm
ANCON WP2130x70x6mm
ROOF TO BE FULLY STRAPPED AND FIXED TO WALLS TO PROVIDE LATERAL RESTRAINT WITH
PROPRIETARY MILD STEEL STRAPS AND STRONGBACKS OR SIMILAR NOGGINS INSTALLED
AND FIXED TO SPECIALIST DESIGNERS SPECIFICATION AND INSTRUCTIONS.
PARAPET COPING AND WATERPROOFING TO ARCHITECT'S DETAILS
BEARING OF MULTI-PLY GIRDER TO BE CONSIDERED BY SPECIALIST DESIGNER. SPREADER MAY BE REQUIRED ONTO WALL.
Project
Drawing Title
Drawing Status.
DrawnDateScale (s)
Job No. Drawing No. Revision
Rev Date By Chk Description
Client
All rights for the intellectual property of the designs shown on this drawing are reserved by Tunstall Smith King Limited. Company Registration Number: 9640811
Tunstall Smith King Limited29 Stoney StreetNottingham NG1 1LP
T. 0115 922 9863E. [email protected]. tskconsulting.co.uk
Classroom Extension, St.Joseph's Catholic PrimarySchool, Shirebrook
Ground Floor and Roof Plan
220103 S/100
BN
CONSTRUCTION
Sept 20201:50@A1; 1:100@A3
C1
St. Joseph's Catholic School
GROUND FLOOR LAYOUT WITH LINTELSOVER
ROOF LAYOUT
C1 04/09/20 BN GT Issued for Construction
1. THE BASE SPECIFICATION FOR FOUNDATION WORKS SHALL BE BS8004 'BRITISH STANDARD CODE OF PRACTICE FOR FOUNDATIONS'.
2. A SITE INVESTIGATION REPORT HAS NOT BEEN PROVIDED. THE REPORT IS TO BE ISSUED TO ALL DESIGN PARTIES ONCE AVAILABLE, AND THE ENGINEER IMMEDIATELY NOTIFIED OF ANY VARIATIONS OF THE GROUND CONDITIONS FROM THE PRELIMINARY REPORTS.
3. FOUNDATIONS HAVE BEEN DESIGNED ASSUMING A NET ALLOWABLE BEARING PRESSURE OF 100 kN/m2 AND SHALL BEAR ONTO A FORMATION TO BE AGREED WITH THE LOCAL AUTHORITY BEFORE CONSTRUCTION COMMENCES.
4. THE ENGINEER IS TO BE INFORMED IMMEDIATELY IF FOUNDATION DEPTHS SUBSTANTIALLY EXCEED THE MINIMUM DEPTHS INDICATED UPON THE DRAWINGS.
5. ALL OBSTRUCTIONS, OLD FOUNDATIONS, DISUSED SEWERS, ETC. SHALL BE REMOVED FOR THE EXTENT OF THE FOUNDATION WORKS AND BACKFILLED TO THE APPROVAL OF THE ENGINEER.
6. ALL STRIP FOOTINGS ARE TO BE SET OUT SYMMETRICALLY ABOUT CENTRE LINES OF SUPPORTED WALLS UNLESS NOTED OTHERWISE. FOR SETTING OUT OF WALLS SEE ARCHITECT'S DRAWINGS.
7. ALL FOUNDATIONS AND SLABS TO BE RC35 MIX IN ACCORDANCE WITH BS8500 UNLESS SITE INVESTIGATION REPORT ADVISES OTHERWISE UPON RECEIPT.
8. UNLESS FOUNDATION FORMATIONS ARE CONCRETE IMMEDIATELY, 50 mm OF BLINDING CONCRETE SHALL BE PROVIDED.
9. ALL MESH REINFORCEMENT LAPS TO BE 400 mm ACHIEVED WITH FLYING ENDS MESH AND NOMINAL CONCRETE COVER TO BE 40 mm.
FOUNDATION NOTES
1. THE BASE SPECIFICATION FOR STRUCTURAL MASONRY SHALL BE BS5628 'CODE OF PRACTICE FOR USE OF MASONRY'. IN ADDITION, REFERENCE SHALL BE MADE TO THE ARCHITECT'S MASONRY SPECIFICATION AND ASSOCIATED DRAWINGS.
2. ALL WALL TIES, REGARDLESS OF POSITION, SHALL BE STAINLESS STEEL IN ACCORDANCE WITH BS1243 & DD140. FISH TAIL OR OTHER TIES WITH SHARP EDGES SHALL NOT BE USED.
3. ALL LINTELS MUST BEAR ONTO SUPPORTING MASONRY 150 mm MINIMUM AND INSTALLED TO MANUFACTURER'S ADVICE AND GUIDANCE.
4. THE SPACING, LOCATION, AND TYPE OF CAVITY WALL TIES SHALL BE IN ACCORDANCE WITH BS5628.
5. WALL MOVEMENT JOINTS WITH DEBONDED SLEEVES HAVE BEEN INDICATIVELY SHOWN ON PLAN. FINAL POSITIONS TO BE AGREED WITH ARCHITECT.
6. ALL MOVEMENT JOINTS SHALL BE REFLECTED IN THE APPLIED FINISHES (E.G. PLASTERWORK, RENDERING, AND CERAMIC TILING).
7. MORTAR CLASSIFICATIONS AS DEFINED IN TABLE 1 OF BS5628: PART 1 TO BE USED IN THE CONSTRUCTION ARE AS FOLLOWS:BELOW DPC - MORTAR DESIGNATION CLASS (i)ABOVE DPC - MORTAR DESIGNATION CLASS (iii)
8. UNLESS OTHERWISE SPECIFIED, THE MINIMUM EMBEDMENT OF WALL TIES SHALL BE 50 mm.
9. CAVITY WALL TIES TO BE GENERALLY LOCATED AT 750 mm HORIZONTAL AND 450 mm VERTICAL CENTRES. AROUND OPENINGS TIES TO BE LOCATED AT 225 mm HORIZONTAL AND 225 mm VERTICAL CENTRES AT OR AROUND OPENINGS NO GREATER THAN 225 mm FROM ANY OPENING.
MASONRY NOTES
1. THE BASE SPECIFICATION FOR STRUCTURAL TIMBER ROOFS SHALL BE BS5268 'STRUCTURAL USE OF TIMBER'.
2. ALL TIMBER SHALL BE FACTORY TREATED IN ACCORDANCE WITH BS5268. SUCH TREATMENT SHALL NOT BE DETRIMENTAL TO ANY FIXINGS IN CONTACT WITH TIMBER MEMBERS.
3. EASI-JOIST RAFTERS INCLUDING ALL NECESSARY PERMANENT & TEMPORARY BRACINGS, LOOSE TIMBERS, ETC. SHALL BE DESIGNED, MANUFACTURERD, AND ERECTED BY A SPECIALIST SUB-CONTRACTOR AND DESIGNER TO PROVIDE A COMPLETE ROOF STRUCTURE AS INDICATED UPON THE DRAWINGS. THE DESIGN SHALL ACCOMMODATE THE FOLLOWING ADVISED LOADINGS:-
• DEAD LOAD - 0.80 kN/m2
• LIVE LOAD - 0.60 kN/m2
• WIND LOAD - REFER TO BS6399• SNOW LOAD - REFER TO BS6399
ALL THE LOADS ABOVE ARE CHARACTERISTIC.
4. THE SPECIALIST SUB-CONTRACTOR SHALL INCORPORATE INTO HIS CONTRACT THE DESIGN OF ALL NECESSARY BRACING TO PROVIDE STABILITY TO THE EASI-JOIST ROOF. UNLESS OTHERWISE ADVISED BY THE ENGINEER, THE SPECIALIST SUB-CONTRACTOR SHALL ASSUME THAT THE ROOF CONSTRUCTION PROVIDES STABILITY TO THE SUPPORTING STRUCTURE. THE SPECIALIST SUB-CONTRACTOR IS THEREFORE RESPONSIBLE FOR DESIGNING AND PROVIDING ALL HORIZONTAL WIND GIRDERS AT EAVES LEVEL, SUFFICIENT TO TRANSMIT WIND LOADS THROUGH THE SUPPORTING STRUCTURE. ANY HORIZONTAL WIND GIRDERS AT EAVES LEVEL INDICATED UPON THE ENGINEER'S DRAWINGS ARE INDICATIVE ONLY.
5. ALL TIMBER FIXINGS SHALL BE IN ACCORDANCE WITH BS5268.
6. ALL TEMPORARY WORKS, BRACING, PROPPING, ETC. SHALL BE DESIGNED BY THE PRINCIPLE CONTRACTOR OR THEIR SPECIALIST SUB-CONTRACTOR AND SUBMITTED FOR APPROVAL.
TIMBER ROOF NOTES
SSL 204.075 SSL 204.075
SSL 204.075 SSL 204.075
SSL 204.075
140mm BLOCKWORK WALL
MIN
300
100x100x100 CAVITY WALL
WS300 EASI-JOISTS
EXISTING WALL
TIED TO EXISTING WALL WITH SCREW CAVITY TIES
EXISTING ROOF RETAINED
EDGE OF EXISTING SLAB / RAFT CUT BACK TO ALLOW FOR PROPOSED MASONRY WALL. EXPOSED FACE MADE GOOD WITH CEMENTITIOUS REPAIR PRODUCT SUCH AS FOSROC RENDEROC OR SIMILAR APPROVED.
FOOTING
400 WIDE
FOOTING
600 WIDE
MIN
300
THK
10 mm COMPRESSIBLE FILLER BOARD ISOLATION JOINT AGAINST MASONRY WALL
10 mm COMPRESSIBLE FILLER BOARD ISOLATION JOINT AGAINST MASONRY WALL
REDUCED WIDTH FOOTING BELOW 140 mm BLOCKWORK WALL
ROOF EDGING, COPING, AND WATERPROOFING TO ARCHITECT'S DETAILS
PARAPET COPING AND WATERPROOFING TO ARCHITECT'S DETAILS
EASI-JOISTS BUILT INTO MASONRY WALL OR SUPPORTED FROM MASONRY HANGERS - TO MANUFACTURER'S DESIGN
150 mm THK RC35 GROUND BEARING SLAB.A252 MESH IN BOTTOM WITH 40mm COVER.ON DPM OVER SAND BLINDED MIN. 150 mm WELL COMPACTED HARD-CORE.
FLOOR FINISHES & INSULATION TO ARCHITECT'S SPECIFICATION
HAR
D-C
OR
EM
IN. 1
50 C
OM
PAC
TED
IN THE ABSENCE OF A SITE INVESTIGATION REPORT A GROUND BEARING SLAB HAS BEEN ADOPTED.
SI TO CONFIRM WHETHER ANY GROUND GAS PRECAUTION MEASURES ARE NEEDED AND DETAILS REVISED AS REQUIRED.
EXISTING SLAB /RAFT LEVEL TBC
MASS CONCRETE STRIP FOOTING
MIN
300
FOOTING
600 WIDE
MIN
300
THK
10 mm COMPRESSIBLE FILLER BOARD ISOLATION JOINT AGAINST MASONRY WALL
PARAPET COPING AND WATERPROOFING TO ARCHITECT'S DETAILS
150 mm THK RC35 GROUND BEARING SLAB.A252 MESH IN BOTTOM WITH 40mm COVER.ON DPM OVER SAND BLINDED MIN. 150 mm WELL COMPACTED HARD-CORE.
FLOOR FINISHES & INSULATION TO ARCHITECT'S SPECIFICATION
HAR
D-C
OR
EM
IN. 1
50 C
OM
PAC
TED
IN THE ABSENCE OF A SITE INVESTIGATION REPORT A GROUND BEARING SLAB HAS BEEN ADOPTED.
SI TO CONFIRM WHETHER ANY GROUND GAS PRECAUTION MEASURES ARE NEEDED AND DETAILS REVISED AS REQUIRED.
MASS CONCRETE STRIP FOOTING
100x100x100 CAVITY WALL
EXISTING WALL
EXISTING ROOF RETAINED
EDGE OF EXISTING SLAB / RAFT MADE GOOD WITH CEMENTITIOUS REPAIR PRODUCT SUCH AS FOSROC RENDEROC OR SIMILAR APPROVED.
10 mm COMPRESSIBLE FILLER BOARD ISOLATION JOINT AGAINST EXISTING SLAB
ROOF EDGING, COPING, AND WATERPROOFING TO ARCHITECT'S DETAILS
EXISTING SLAB /RAFT LEVEL TBC
WS300 EASI-JOISTS
MIN
300
MIN
300
THK
10 mm COMPRESSIBLE FILLER BOARD ISOLATION JOINT AGAINST MASONRY WALL
150 mm THK RC35 GROUND BEARING SLAB.A252 MESH IN BOTTOM WITH 40mm COVER.ON DPM OVER SAND BLINDED MIN. 150 mm WELL COMPACTED HARD-CORE.
FLOOR FINISHES & INSULATION TO ARCHITECT'S SPECIFICATION
IN THE ABSENCE OF A SITE INVESTIGATION REPORT A GROUND BEARING SLAB HAS BEEN ADOPTED.
SI TO CONFIRM WHETHER ANY GROUND GAS PRECAUTION MEASURES ARE NEEDED AND DETAILS REVISED AS REQUIRED.
MASS CONCRETE STRIP FOOTING
EXISTING WALL
EXISTING CANOPY RETAINED TO FORM ROOF TO BREAKOUT ROOM
EDGE OF EXISTING SLAB / RAFT MADE GOOD WITH CEMENTITIOUS REPAIR PRODUCT SUCH AS FOSROC RENDEROC OR SIMILAR APPROVED.
10 mm COMPRESSIBLE FILLER BOARD ISOLATION JOINT AGAINST EXISTING SLAB
EXISTING SLAB /RAFT LEVEL TBC
HAR
D-C
OR
EM
IN. 1
50 C
OM
PAC
TED
FOOTING
600 WIDE
100x100x100 CAVITY WALL
FLASHING TO EXISTING CANOPY / ROOF TO ARCHITECT'S DETAILS
100x100x100 CAVITY WALL
EXISTING SLAB /RAFT LEVEL TBC
EDGE OF EXISTING SLAB / RAFT CUT BACK TO ALLOW FOR PROPOSED MASONRY WALL. EXPOSED FACE MADE GOOD WITH CEMENTITIOUS REPAIR PRODUCT SUCH AS FOSROC RENDEROC OR SIMILAR APPROVED.
10 mm COMPRESSIBLE FILLER BOARD ISOLATION JOINT AGAINST MASONRY WALL
FOOTING
600 WIDE
EXISTING ROOF RETAINED
ROOF EDGING, COPING, AND WATERPROOFING TO ARCHITECT'S DETAILS
WS300 EASI-JOISTS
MASS CONCRETE STRIP FOOTING
FLOOR FINISHES & INSULATION TO ARCHITECT'S SPECIFICATION
150 mm THK RC35 GROUND BEARING SLAB.A252 MESH IN BOTTOM WITH 40mm COVER.ON DPM OVER SAND BLINDED MIN. 150 mm WELL COMPACTED HARD-CORE.
Project
Drawing Title
Drawing Status.
DrawnDateScale (s)
Job No. Drawing No. Revision
Rev Date By Chk Description
Client
All rights for the intellectual property of the designs shown on this drawing are reserved by Tunstall Smith King Limited. Company Registration Number: 9640811
Tunstall Smith King Limited29 Stoney StreetNottingham NG1 1LP
T. 0115 922 9863E. [email protected]. tskconsulting.co.uk
Classroom Extension, St.Joseph's Catholic PrimarySchool, Shirebrook
Building Sections
220103 S/110
BN
CONSTRUCTION
Sept 20201:20@A1; 1:40@A3
C1
St. Joseph's Catholic School
SECTION A
SECTION B SECTION C
SECTION D
C1 04/09/20 BN GT Issued for Construction
MIN
300
FOOTING
600 WIDE
MIN
300
THK
10 mm COMPRESSIBLE FILLER BOARD ISOLATION JOINT AGAINST MASONRY WALL
150 mm THK RC35 GROUND BEARING SLAB.A252 MESH IN BOTTOM WITH 40mm COVER.ON DPM OVER SAND BLINDED MIN. 150 mm WELL COMPACTED HARD-CORE.
HAR
D-C
OR
EM
IN 1
50 C
OM
PAC
TED
MASS CONCRETE STRIP FOOTING
DPC, DPM, AND VENTING TO ARCHITECT'S DETAIL
EXISTING SLAB /RAFT LEVEL TBC
EDGE OF EXISTING SLAB / RAFT CUT BACK TO ALLOW FOR PROPOSED MASONRY WALL. EXPOSED FACE MADE GOOD WITH CEMENTITIOUS REPAIR PRODUCT SUCH AS FOSROC RENDEROC OR SIMILAR APPROVED.
10 mm COMPRESSIBLE FILLER BOARD ISOLATION JOINT AGAINST MASONRY WALL
FOOTING
600 WIDE
MASS CONCRETE STRIP FOOTING
150 mm THK RC35 GROUND BEARING SLAB.A252 MESH IN BOTTOM WITH 40mm COVER.ON DPM OVER SAND BLINDED MIN. 150 mm WELL COMPACTED HARD-CORE.
HAR
D-C
OR
E15
0 C
OM
PAC
TED
EDGE OF EXISTING SLAB / RAFT CUT BACK TO ALLOW FOR PROPOSED MASONRY WALL. EXPOSED FACE MADE GOOD WITH CEMENTITIOUS REPAIR PRODUCT SUCH AS FOSROC RENDEROC OR SIMILAR APPROVED.
FOOTING
400 WIDE
10 mm COMPRESSIBLE FILLER BOARD ISOLATION JOINT AGAINST MASONRY WALL
REDUCED WIDTH FOOTING BELOW 140 mm BLOCKWORK WALL
EXISTING SLAB /RAFT LEVEL TBC
HAR
D-C
OR
E15
0 C
OM
PAC
TED
EDGE OF EXISTING SLAB / RAFT MADE GOOD WITH CEMENTITIOUS REPAIR PRODUCT SUCH AS FOSROC RENDEROC OR SIMILAR APPROVED.
10 mm COMPRESSIBLE FILLER BOARD ISOLATION JOINT AGAINST EXISTING SLAB
EXISTING SLAB /RAFT LEVEL TBC
HAR
D-C
OR
EM
IN 1
50 C
OM
PAC
TED
20 mm WIDE SLAB JOINT,MESH STOPPED EACH SIDE
FOSROC THIOFLEX 600 JOINT SEALANT OR SIMILAR APPROVED, 20 mm DEEP
16 mm⌀
600 mm LONG DOWEL BAR @ 200 mm C/C ALONG JOINT, WITH
DEBONDING SLEEVE ONE SIDE
FOSROC EXPANDAFOAM JOINT FILLER, INSTALLED TO MANUFACTURER'S GUIDANCE
ANCON WP2130x70x6mm
10 R
ECES
S
ANCON SNS TIE 225 mm
ANCON SDN TIE 125 mm
WIND POST FIXED DOWN TO FOUNDATIONS AND UP INTO
TIMBER WALL PLATE
Project
Drawing Title
Drawing Status.
DrawnDateScale (s)
Job No. Drawing No. Revision
Rev Date By Chk Description
Client
All rights for the intellectual property of the designs shown on this drawing are reserved by Tunstall Smith King Limited. Company Registration Number: 9640811
Tunstall Smith King Limited29 Stoney StreetNottingham NG1 1LP
T. 0115 922 9863E. [email protected]. tskconsulting.co.uk
Classroom Extension, St.Joseph's Catholic PrimarySchool, Shirebrook
Foundation & Ground FloorDetailed Sections
220103 S/120
BN
CONSTRUCTION
Sept 20201:10@A1; 1:20@A3
C1
St. Joseph's Catholic School
SCALE 1 : 10@A1
DETAIL 1
C1 04/09/20 BN GT Issued for Construction
SCALE 1 : 10@A1
DETAIL 2SCALE 1 : 10@A1
DETAIL 3SCALE 1 : 10@A1
DETAIL 4
SCALE 1 : 5@A1
DETAIL 5 - SLAB JOINTSCALE 1 : 5@A1
DETAIL 6 - WIND POST
HYDRO-BRAKE FLOW CONTROL DETAIL
TYPICAL MANHOLE DETAILS
DEPTH FROM COVER LEVEL TO SOFFIT OF PIPE MAX 3m
GRANULAR BEDDING - TYPE S
2000 4000
2.25m
1 : 40
1 : 40
150mm THICK TYPE 1 SUBBASE
TENSAR TRI AXIAL GEOGRID
SURFACE COURSE - 40mm
THK. AC10 CLOSE SURF
100/150 TO BS EN 13108-1
PSV 68 (ABSOLUTE
MINIMUM 65+) 20 YEAR
DESIGN LIFE WITH 20 MSA
175mm THICK RC
CONCRETE SLAB
WITH 2 LAYERS A393
MESH 1 TOP & 1
BOTTOM
150mm THICK TYPE 1 SUBBASE
TENSAR GEOGRID TO
CONTINUE 2m OVER PIPES
1000
ATTENUATION STORAGE CRATES
FLEXIBLE
ROAD
CONSTRUCTION
PIPE PROTECTION
ROAD
CONSTRUCTION
TENSAR GEOGRID TO
CONTINUE FULL LENGTH OF
PIPES
ATTENUATION STORAGE CRATES
ATTENUATION
CRATES TO BE
INSTALLED TO
MANUFACTURERS
DETAILS
ASSUMED EXISTING FORMATION
TYPICAL ATTENUATION TANK
TYPICAL TRANSITION DETAIL
TYPICAL SECTION
SCALE 1:10
POLYPROPYLENE INSPECTION CHAMBER
(PPIC)
Project
Drawing Title
Drawing Status
DrawnDateScale (s)
Job No. Drawing No. Revision
Rev Date By DescriptionChk
Client
Tunstall Smith King Limited
37 Wollaton Road, Beeston
Nottingham NG9 2NG
T. 0115 922 9863
W. tskconsulting.co.uk
This drawing is to be read in conjunction with all
relevant architects, engineers and specialists
drawings and specifications.
Do not scale from this drawing.
All rights for the intellectual property of the designs shown on this drawing are
reserved by Tunstall Smith King Limited. Company Registration Number: 9640811
220103 C/002 T1
TENDER
Classroom Extension
Drainage Details
AS SHOWN Oct 20 GT
NOT FOR CONSTRUCTION
T1 10/10/20 GT PSm For Tender Issue
St Josephs Catholic
Primary School
Gy
Gy
IC
ST
DP
DP
DP
DP
THL
Pipe
Pipe
Pipe
F2
98.757
F3
98.693
9
8
.
7
6
9
8
.
5
3
9
8
.
4
8
9
8
.
4
6
9
8
.
9
5
99.49
1
0
3
.
4
7
1
0
3
.
3
9
103.22
9
8
.
8
6
9
8
.
6
9
9
8
.
6
1
9
8
.
5
0
98.33
9
8
.
5
1
9
8
.
4
3
9
8
.
3
9
9
8
.
3
4
98.32
9
8
.
6
1
9
8
.
6
1
98.53
98.37
98.39
98.39
9
8
.
5
3
9
8
.
4
2
9
8
.
4
7
9
8
.
5
5
9
8
.
4
0
9
8
.
4
4
9
8
.
4
4
98.28
98.24
9
8
.
2
0
98.27
9
8
.
4
7
98.45
9
8
.
4
5
9
8
.
3
4
9
8
.
4
3
9
9
.
0
1
9
8
.
9
3
9
8
.
8
0
9
8
.
7
5
9
8
.
7
5
O
p
e
n
P
a
n
e
l
F
e
n
c
e
h
t
0
.
9
m
IC
MH
Gy
CVR
Gy
Sign
Clothes
Bank
Gas
IC
CVR(Slab)
Tarmac
Tarmac
Concrete
Paving
Grass
Bushes
Safety
Surface
Shed
Tarmac
S
t
e
e
l
M
e
s
h
F
e
n
c
e
h
t
2
.
3
m
S
t
e
e
l
M
e
s
h
F
e
n
c
e
h
t
2
.
3
m
S
t
e
e
l
M
e
s
h
F
e
n
c
e
h
t
2
.
3
m
Gy
Gravel
98.18
Gy
D
r
a
i
n
a
g
e
D
u
c
t
O
verhead C
able
O
v
e
r
h
e
a
d
C
a
b
le
9
9
.
0
1
0
0
1
0
0
0
.
4
7
d
1
0
0
IL97.70
1
0
0
Grease Trap
2
.
1
0
d
1
.
7
0
d
1
.
2
8
d
1
0
0
IL96.90
BD 0.42d
1
0
0
Silted
1
.
0
0
d
0
.
6
8
d
0
.
6
8
d
0
.
5
4
d
0
.
6
4
d
0
.
5
8
d
0
.
5
4
d
0
.
4
2
d
0
.
4
5
d
0
.
3
4
d
0
.
4
6
d
0
.2
7
d
0
.
5
0
d
0
.
4
0
d
IL97.67
1
0
0
0
.
8
3
d
0
.
8
5
d
1
.
3
1
d
Surcharged
IL97.99
No Incoming
Pipes Visible
1
0
0
1
0
0
1
0
0
UTS
2.00d
1
0
0
UTS
B
4
IL97.08
1
0
0
1
0
0
1
0
0
BD 0.64d
BD 0.64d
Safety
Surface
Shelter
Play
Zone
Play
Zone
Play
Zone
Project
Drawing Title
Drawing Status
DrawnDateScale (s)
Job No. Drawing No. Revision
Rev Date By DescriptionChk
Client
Tunstall Smith King Limited
37 Wollaton Road, Beeston
Nottingham NG9 2NG
T. 0115 922 9863
W. tskconsulting.co.uk
This drawing is to be read in conjunction with all
relevant architects, engineers and specialists
drawings and specifications.
Do not scale from this drawing.
All rights for the intellectual property of the designs shown on this drawing are
reserved by Tunstall Smith King Limited. Company Registration Number: 9640811
220103 C/001 T1
TENDER
Classrom Extension
Drainage Layout
AS SHOWN Oct 20 GT
NOT FOR CONSTRUCTION
1. THE LOCATION AND LEVEL OF EXISTING DRAINAGE
CONNECTIONS AND EXISTING SERVICES IS TO BE
CHECKED PRIOR TO COMMENCEMENT OF DRAINAGE
WORKS. ANY VARIANCE TO THE DETAILS ON THIS
DRAWING AND THE SCHEDULE IS TO BE BROUGHT TO THE
ATTENTION OF THE ENGINEER.
2. THE DESIGN IS BASED ON THE INFORMATION
AVAILABLE ON THE DATE OF ISSUE FROM OTHER PARTIES
(EG. ARCHITECT AND M & E ENGINEER). IT IS SUBJECT TO
CHANGE RESULTING FROM UPDATES TO THE AVAILABLE
INFORMATION FROM OTHERS.
3. THE DRAWINGS ARE TO BE READ IN CONJUNCTION
WITH THE NBS SPECIFICATIONS, ASSOCIATED MANHOLE
SCHEDULE AND STANDARD DRAINAGE DETAIL DRAWINGS.
4. THE POSITIONS OF FOUL AND SURFACE WATER
DRAINAGE POINTS ARE INDICATIVE ONLY, REFER TO THE
ARCHITECTS DRAWINGS FOR SETTING OUT DETAILS.
5. MANHOLES, SEWERS, LATERAL CONNECTIONS ETC
AND ANY OTHER PART OF THE WORKS INTENDED FOR
ADOPTION UNDER A SECTION 104 AGREEMENT OR
GULLIES ETC INTENDED FOR ADOPTION AS HIGHWAY
DRAINAGE ARE TO BE CONSTRUCTED IN ACCORDANCE
WITH SEWERS FOR ADOPTION 6TH EDITION (OR
LATEST) AND TO THE APPROVAL OF THE WATER AND
HIGHWAY AUTHORITIES.
6. UNADOPTED FW AND SW DRAINAGE IS TO BE
CONSTRUCTED IN ACCORDANCE WITH THE CURRENT
BUILDING REGULATIONS, BS EN752 AND BS EN12056.
7. DRAINS ARE TO BE CONSTRUCTED USING FLEXIBLY
JOINTED VITRIFIED CLAY PIPES TO BS EN 295-1 SUPER
STRENGTH SPECIFICATION (EG HEPWORTH SUPERSLEVE
OR SIMILAR APPROVED) OR UPVC BUILDING DRAINAGE
SYSTEM PIPEWORK TO BS 4660 AND BS EN1401-1, BEDDED
AND BACKFILLED IN ACCORDANCE WITH THE
MANUFACTURERS INSTRUCTIONS AND THE
SPECIFICATIONS UNLESS OTHERWISE SPECIFIED.
8. ALL SOIL CONNECTIONS UNDER BUILDINGS TO BE
100mm DIA LAID AT A MINIMUM GRADIENT OF 1/40 UNLESS
NOTED OTHERWISE AND SHOULD BE RODDABLE FROM
GROUND LEVEL.
9. ALL RWP CONNECTIONS TO BE 100mm DIAMETER
AND TO BE LAID AT A MINIMUM GRADIENT OF 1/80 UNLESS
NOTED OTHERWISE AND SHOULD BE RODDABLE FROM
ABOVE GROUND LEVEL.
10. RAINWATER DOWN PIPES TO CONNECT TO A DRAIN
VIA A REST BEND OR BE CONNECTED DIRECT TO A
TRAPPED GULLY ON A COMBINED SYSTEM.
11. CHANNEL DRAINS TO BE ACO M100D 0.0 WITH SUMP
UNIT OR SIMILAR APPROVED. GRATING TO BE IN
ACCORDANCE WITH ARCHITECT OR LANDSCAPE
ARCHITECT SPECIFICATION.
12. IN CASES OF IN SITU CONCRETE FLOORS DRAINS
ARE TO BE CAST INTEGRAL WITH THE SLAB WHERE PIPE
COVER TO THE CROWN IS LESS THAN 300mm.
13. IN CASES OF SUSPENDED FLOORS WHERE A VOID
OF 300mm OR MORE EXISTS BELOW FLOOR DRAINS ARE
TO BE SUSPENDED USING A PROPRIETARY HANGER
SYSTEM OR CAST INTEGRAL WITH THE FLOOR.
14. WHERE DRAINS PASS THROUGH FOUNDATIONS OR
OTHER RIGID STRUCTURES A LINTEL OR SLEEVE IS TO BE
USED AND PROVISION FOR FLEXIBILITY IS TO BE MADE
USING ROCKER PIPES.
15. BACKFILLING OF DRAIN TRENCHES ADJACENT TO
BUILDING OR OTHER STRUCTURES IS TO BE IN
ACCORDANCE WITH DIAGRAM 8 OF THE BUILDING
REGULATIONS.
16. DRAINS WITHIN AREAS OF MADE GROUND TO BE
CONSTRUCTED BY FIRST MAKING UP THE AREA TO
APPROX. FINISHED LEVEL AND THEN EXCAVATING
THROUGH THE FILL MATERIAL INTO UNDISTURBED
GROUND. THE DRAIN TRENCH IS THEN TO BE BACKFILLED
TO FORMATION LEVEL USING SUITABLE GRANULAR FILL
MATERIAL WELL COMPACTED IN LAYERS NOT EXCEEDING
225mm.
DRAINAGE NOTES
T1 10/10/20 GT PSm For Tender Issue
St Josephs Catholic
Primary School