Upload
hoangnguyet
View
233
Download
0
Embed Size (px)
Citation preview
2308 Circuit Way • Brooksville, Florida 34604 • Ph.: 352.277.0606 • Toll Free: 844-EQUILAM
Fax: 352.277.0608 • www.equilamna.com • [email protected] Rev 06
SS Series
Specifications/Details SS600 SS1300 SS3000
Salt Spray (Salt Fog)
Temperature Range Amb. +9°F (Amb. +5°C) to 131°F (55°C)
Bubble Tower
Temperature Range Amb. +9°F (Amb. +5°C) to 165°F (74°C)
Condensation
Humidity Temperature
Range
Amb. +9°F (Amb. +5°C) to 140°F (60°C)
97% +/- 3%
Soak Temperature
Range Amb. +9°F (Amb. +5°C) to 122°F (50°C)
Natural Dry
Temperature and
Humidity Range
Ambient (labs) Temperature and Humidity
Programming Modes:
- Salt Spray
- Condensation Humidity
- Natural Dry
- Soak
- ASTM G 85 A.3 (SWAAT TEST) (optional *1)
User Interface
Platform
Touch Screen Color
Trend Plot of Test
Parameters on touch
screen
Yes
Lid Safety System Yes
UL 508a Compliant Yes
Alarm message,
recommended
maintenance
displayed on touch
screen
Yes
Critical test
parameters displayed
on one screen
Yes
20 Programmed Tests Yes
Error messages
displayed Yes
2308 Circuit Way • Brooksville, Florida 34604 • Ph.: 352.277.0606 • Toll Free: 844-EQUILAM
Fax: 352.277.0608 • www.equilamna.com • [email protected] Rev 06
Visual Safety/Alarm
System (Touch Screen) Yes
Data Acquisition
Software
Data
Acquisition Software:
2 types: PC or SD Card.
2 Types: SD Card (On touch screen) PC (RS 232 or USB)
Central atomization
tower providing better
fog distribution inside
the chamber as
requested on page 4 of
ASTM B117 and Annex
A ISO 9227.
Pneumatic Lid with
Safety Systems
2308 Circuit Way • Brooksville, Florida 34604 • Ph.: 352.277.0606 • Toll Free: 844-EQUILAM
Fax: 352.277.0608 • www.equilamna.com • [email protected] Rev 06
External Fog Collection
Multi-day, continous
test tank.
Minimum/maximum
level indication.
Automatic and manual
mixing settable in
touch-screen PLC.
1 – Indirect Heating through water jacket according to ASTM B-117 to ensure
that no metallic heating will affect corrosivity of testing results.
2 - Lid designed with smooth surface, without seams, per ASTM B-117,
for prevention of contamination from solution drip.
3 - Unibody construction incorporating solution tank, bubble tower in
one cabinet.
4- Central Atomization Tower built to ASTM B 117 standards ensuring
fog uniformity and homogenous results.
Exterior Dimensions
W x D x H
1,890 x 1,060 x 1,420
75”x 42”x 56”
2,480 x 1,250 x 1,645 mm
97.6” x 49.2” x 64.8” 3,400 x 1,600 x 1,800 mm
133.9” x 63.0” x 70.9”
Interior Dimensions
W x D x H
820 x 650 x 780 mm
32.3” x 25.6” x 30.7” 1,300 x 780 x 900 mm
51.2” x 30.7” x 35.4” 2,080 x 1,080 x 1,000 mm
81.9”x 42.5”x 39.4”
Exterior Dimensions
Lid Open
W x D x H
1,890 x 1,060 x 1,650 mm
75”x 42”x 65”
2,480 x 1,250 x 1,700 mm
97.6” x 49.2” x 66.9” 3,400 x 1,600 x 2,200 mm
133.9” x 63” x 86.6”
Crated Dimensions
Approximate
W x D x H
2,000 x 1,200 x 1,650 mm
79”x 48”x 65”
2,600 x 1,300 x 1,850 mm
102.4” x 51.2” x 72.8”
3,550 x 1,700 x 2,110 mm
139.8” x 66.9” x 83.1”
Move-in Dimensions
W x D x H
2,100 x 1,300 x 1,750 mm
82”x 52”x 69”
2,700 x 1,400 x 1,950 mm
106.3” x 55.1” x 76.8” 3,650 x 1,800 x 2,210 mm
143.7” x 70.9” x 87.0”
Net Weight (Empty) 364 lbs (165 kg) 639 lbs (290 kg) 1,323.5 lbs (600 kg)
2308 Circuit Way • Brooksville, Florida 34604 • Ph.: 352.277.0606 • Toll Free: 844-EQUILAM
Fax: 352.277.0608 • www.equilamna.com • [email protected] Rev 06
Gross Weight (crated) 551 lbs (250 kg) 772 lbs (350 kg) 1,742 lbs (790 kg)
Chamber Volume (w/
lid) 159 gal (600 l) 343 gal (1300 l) 793 gal (3000 l)
Ambient Temperature
Requirements +63°F - +82°F (+17°C - +28°C)
Ambient Humidity
Requirements max. 85% without condensation
Power 208-230V - 50-60Hz - 1 phase
FLA (230V) 25A 32A 40A
Water Quality ASTM D 1193 Type IV
Water Supply 7 to 28 psi (0.5 to 2.0 kgf/cm²)
Water Connection ½ NPT"
Water Usage 20 liters per day 35 liters per day
Solution Usage 12 liters per day 23 liters per day
Gravity Drain ½ NPT" hose barb fitting
Exhaust Tube 2” 4”
Custom chambers upon request
*1 Plug for SWAAT Test.