27
PAGE 1 IPT MWR Product Management EDITOR: COO IPT MWR PRODUCT MANAGEMENT PUBLISHER: SSM IPT MWR SUBJECT SRAL XD CUSTOMER FEATURE LIST CFL-011003-1 CFL-011003-1 ISSUE 19 UPDATE: DECEMBER 2008 Nokia Siemens Networks Customer Feature List PDH Radio SRAL XD

SRAL XD Customer Feature List

Embed Size (px)

Citation preview

PAGE 1

IPT MWR Product Management

EDITOR: COO IPT MWR PRODUCT MANAGEMENT

PUBLISHER: SSM IPT MWR

SUBJECT SRAL XD CUSTOMER FEATURE LIST

CFL-011003-1 CFL-011003-1

ISSUE 19

UPDATE: DECEMBER 2008

Nokia Siemens Networks

Customer Feature List

PDH Radio

SRAL XD

PAGE 2

IPT MWR Product Management

This document is issued on behalf of Nokia Siemens Networks by: Nokia Siemens Networks COO IPT MWR PM S.S. 11 Padana Superiore Km.158 20060 Cassina de’ Pecchi (Milan) Italy

The information contained herein is the property of Nokia Siemens Networks and is supplied without liability for errors or omission. The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Infringes will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Technical modifications are possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.

PAGE 3

IPT MWR Product Management

Table of contents

1. INTRODUCTION ........................................................................................................5

2. SCOPE .......................................................................................................................5

3. FEATURE LIST ..........................................................................................................6

3.1 SRAL XD PLUG-IN VERSION........................................................................................................................... 6

3.2 SRAL XD SINGLE BOARD VERSION........................................................................................................... 14

3.3 SRAL XD SINGLE BOARD2 VERSION......................................................................................................... 17

3.4 SRAL XD TWOE1 VERSION........................................................................................................................... 21

3.5 SRAL XD OUTDOOR ACCESS UNIT (FULLY OUTDOOR) VERSION ................................................... 24

History

Issue Date Author Notes

1.0 October 2003 F. Tammaro First Issue

2.0 January 2004 D. Cattelan Up to SVR 3.5, 4.5, 6.2

3.0 February 2004 D. Cattelan Revision-Up to SVR 3.5, 4.5, 6.5

4.0 July 2004 F. Tammaro Revision-Up to SVR 3.5, 4.6, 6.5

5.0 October 2004 D. Cattelan Revision-Up to SVR 3.5, 4.6, 6.5,1.3

6.0 December 2004 D. Cattelan Revision of SVR 3.5, removal of SVR 4.6 and SVR 6.5

7.0 May 2005 F.Tammaro Up to SVR 3.6, Removed SVR 6.3

8.0 September 2005 D. Cattelan Insertion of SVR 2.5

9.0 February 2006 D. Cattelan Insertion of SVR 3.7

10.0 March 2006 D. Cattelan Minor editorial revisions

11.0 April 2006 D. Cattelan Minor Revision

12.0 September 2006 V. Colaleo Insertion of SVR 3.8 and 7.5

13.0 December 2006 V. Colaleo Insertion of SVR 7.7

14.0 January 2007 V. Colaleo Insertion of SVR 3.9

15.0 January 2008 S. Bonetti Revision of SVR 3.9

16.0 March 2008 S. Bonetti Insertion of SVR 3.10

17.0 May 2008 S. Bonetti Revision of SVR 3.10

18.0 June 2008 S. Bonetti Revision of SVR 3.10, Dynamic modulation availability and of ND2/HDe ODU support

19.0 December 2008 S. Bonetti Revision with SVR 3.10 SU11 (3.10.4)

1 Standard Update 1, Maintenance release

PAGE 4

IPT MWR Product Management

PAGE 5

IPT MWR Product Management

1. INTRODUCTION

This document represents the Official Features List of the product SRAL XD developed by Nokia Siemens Networks.

2. SCOPE

From SW embedded perspective, SRAL XD product line is split into four different families of System Version Releases (SVR): SVR 1.x relevant to IDU TwoE1 family SVR 2.x relevant to OAU (Outdoor Access Unit) family SVR 3.x relevant to IDU Plug-in family SVR 4.x relevant to IDU SingleBoard family SVR 7.X relevant to IDU SingleBoard2 family Notice that all the four IDU/OAU families support both ODU ND and ODU HD (HD/HP or HDe), except IDU TwoE1 family that supports ODU ND only.

PAGE 6

IPT MWR Product Management

3. FEATURE LIST

The Feature List gives information about features supported by each System Version Release. For information relevant to HW and SW availability, please refer to product road map.

3.1 SRAL XD PLUG-IN VERSION

3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10

1.1 Capacities

2/4/8/16xE1 SW selectable on IDU PI 16xE1 version X X X X X X X X

1xE3+E1 WaySide X X X X X X

32xE1 (fixed) on IDU PI 32xE1 version X

4/8/16/32xE1 on IDU PI 32xE1 version X X X

2/4/8/16xT12 SW selectable

X X X X X X X

4x10/100BaseT+8xE1 X X X X X

3x10/100BaseT+1x1000Base-T/Base-X+16xE1 (up to 32xE1 on air)

X

1.2 Outdoor Unit

ODU HDe 3 X X X X X X

ODU HD/HP4 X X X X X X X X

ODU ND X X X X X X X X

ODU ND2 X X X X X X

1.3 Indoor Unit Cards

Controller X X X X X X X X

Controller with fans X X X X X X X

Controller with RS-485 X X X X X X

16xE1 Access Board X X X X X X X X

32xE1 Access Board X X X X

NxT1 Access Board X X X X X X X

16xE1 Base Band module X X X X X X X X

32xE1 Base Band module X X X X

E3 Access Board X X X X X X

E3 Base Band module X X X X X X

Ethernet Access Card (8xE1 + 4xFE) X X X X X

2 HD option not available

3 ODU HDe is able to perform both Normal density and High density channel arrangement. Supported

capacities are 4/8/16/32xE1. Due to HW constraints, High density arrangement is available on 8E1, 16E1/E3 and 32E1. 4 ODU HD/HP is able to perform both Normal density and High density channel arrangement. Supported

capacities are 2/4/8/16xE1.Due to HW constraints, High density arrangement is available on 8E1 and 16E1/E3.

PAGE 7

IPT MWR Product Management

3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10

Access Card 16xE1+3X10/100baseT+1xGE (SFP) X

16xE1 on mini RJ-21 X

3x 10/100 Base T autosensing RJ-45 X

Gigabit Ethernet on SFP X

Electrical 1x10/100/1000 Base T autosensing via SFP X

Optical Gigabit Ethernet Long Range (1000 Base LX) via SFP

X

HW ready for Spanning Tree X

1.4 Service Facilities

Voice Service Channel via IP on a single link (IP telephone/Netmeeting)

X X X X X X X X

10/100 BaseT NMS channel (Q Ch) X X X X X X X X

10BaseT NMS channel (V Ch) X X X X X X X X

64 Kbit/s V.11 (2x) selectable as -NMS Channel (Dext Ch) or -User Channel

X X X X X X X X

64 Kbit/s Embedded NMS Channel (D embedded Ch)5

X X X X X X X X

2 Mb/s G.703 Wayside Channel6 X X X X X X

128kbit/s RS-485 (V bus) for interworking with SRA L7 X X X X X X

F interface RS-232 (LCT) X X X X X X X X

Interworking over F Interface X X X X X X X

Standard IP protocol stack over NMS channels X X X X X X X X

2 CONFIGURATIONS

(1+0) Terminal X X X X X X X X

2x(1+0) Terminal8 X X X X X X X X

(1+1) Frequency/Polarization diversity X X X X X X X X

(1+1) Hot Stand-by X X X X X X X X

Add/Drop Repeater (including 2x(1+0))9 X X X

X X X X X

Ring (including 2x(1+0) and Add-Drop/ Repeater)10

X X X

(1+0) with two trunks X

(1+1)Hsby with two trunks X

(1+1)FD/PD with two trunks X

5 Not Available for ANSI Version

6 64 Kb/s D embedded functionality included.

7 With new controller card only. When Vbus channel is working, Q channel and V channel are disabled 8 Available on IDU Plug-in 16xE1

9 Available on IDU Plug-in 16xE1 and, starting from SVR 3.10, IDU Plug-In 32xE1 with 16xE1+3xFE+1xGE

Access unit 10

On IDU Plug-in 32xE1 with 32xE1 Access unit

PAGE 8

IPT MWR Product Management

3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10

3 FEATURES

3.1 Configuration management

Spectrum efficiency selection (ND/HD) X X X X X X X X

Tx/Rx frequency selection X X X X X X X X

Tx and Rx Freq.Range Display X X X X X X X X

RF channel management: Frequency plan

11

Continuous mode

X X

X X

X X

X X

X X

X X

X X

X

Tx output power selection mode (fixed, ATPC)

X X X X X X X

Tx output power setting (fixed mode) X X X X X X X X

Capacity selection (NxE1)12

X X X X X X X X

2 Mb/s tributary lines disabling/enabling X X X X X X X X

RF channel configuration self-alignment (protected configuration)

X X X X X

E1 cross connect13

matrix X X X X X X X

Cross-connect matrix saving on IDU 16xE1 in case of System Type change from 1+0-Radio Capacity up to 8xE1, to Add-drop/Repeater or 2+0

X X

E1 cross-connect matrix enhanced on IDU PI 16xE1 : Add-drop of all E1, no constraints on pass-trough

X X X

E1 cross connect capabilities on IDU PI 32xE1 : Add-drop of all E1, no constraints on pass-trough (up to 32 connections)

X X X

Cross-connect matrix saving for any system type change

X X X

2 Mb/s tributary lines add/drop selection (add/drop repeater)

14

X X X X X X X X

System activation (on/off) (TX squelch) X X X X X X X X

Dembedded Channel enabling/disabling X X X X X X X X

Dembedded Ch Drop/insert & Time Slot assignment X X X X X X X X

64Kbit/s User Channel mode selection (co/contra-directional)

X X X X X X X X

Automatic F Interface configuration between LCT only or LCT/NMS channel

X X X X X X X

NMS channel protocol stack selection (SRA L like / standard IP stack)

X X X X X X X X

MTU Setting X X X X X X

Ethernet – Vbus Bridiging Enabling/Disabling X X X X X X

11

Channel spacing: 3.5, 7, 14 (13.75), 28 (27.5) MHz for Normal Density arrangement; 7, 14 (13.75) MHz, 28 (27.5) MHz for High Density arrangement. 12 Not Available for E3 versions

13 Managed by LCT. It is managed also by Netviewer from version 6.0 onwards.

14 Not Available for 32xE1, E3 and Data versions

PAGE 9

IPT MWR Product Management

3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10

Security enabling/disabling via password X X X X X X X X

Link identification code X X X X X X X X

NE IP Address and net mask configuration X X X X X X X X

Modulation index setting (BW 99% adaptation)

15

X X X X X X X X

3.2 Ethernet

Forwarding Mode:

LAN/TRUNK Port- Fully Interconnected X

LAN/TRUNK Port- Isolated X

LAN Port isolated; full connected TRUNK port X

LAN Port full connected; TRUNK port isolated X

VLAN forwarding mode: VLAN ID Based VLAN ID Based -No tagging VLAN ID Based - Tagging and Overwrite

X X X

X X X

X X X

X X X

X X X

Double VLAN Tagging (LAN to TRUNK) X

VLAN tag removal X

Bit rate limitation on Ethernet port X

2nd trunk port (e.g. for separation of Real Time traffic and Non Real Time Traffic)

X

Ethernet over Radio E1 mapping

X X X X X

Ethernet Switching X X X X X

Ethernet Port Enabling/Disabling X X X X X

Switching Mode LAN Port Fully Interconnected Isolated Port VLAN Based No Tagging Tagging and Overwrite

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

QoS16

: Classification

802.1Q VLAN ID LAN port

802.1p IP Based

Scheduling Fixed Priority

WFQ

X X X

X X

X X X

X X

X X X

X X

X X X

X X

X X X X

X X

15

Available with ODU ND only 16

on IDU PI 32xE1 ETH. Please note: on IDU PI 16xE1 ETH Fixed Priority and WFQ have been verified as underperforming and therefore removed starting from SVR 3.10 Standard Update 1 (SU1). The behaviour will be fixed in a future Standard Update.

PAGE 10

IPT MWR Product Management

3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10

3.1.1. Dynamic Modulation

on IDU Plug-in 16xE1 version X X

on ODU HD/HP and HDe17

X X

on mixed link ODU HD/HP-ODU HDe X X

on System types 1+0 and 1+1 Hot Stand-by X X

Payload loss < 2 seconds X X

Switch logic based on S/N Measurement X X

Interworking with ATPC X X

ATPC boost (+X dB18

on Tx Power in 16TCM) X

Enable/Disable Dynamic Modulation X X

Enable/Disable ATPC boost X

Working modes of Dynamic Modulation with IDU Plug-in 16xE1 versions

4QAM-Normal (4xE1 and 8xE1) X X

16TCM-Enhanced (8xE1 and 16xE1) X X

Unique Working Modes for TX and RX direction X X

Switch criteria configurable parameters:

Hysteresys respect to low and high thresholds X X

Check of simultaneous switching conditions before passing from Normal Working Mode to Enhanced Working Mode for a configurable time window

X X

Selection of E1 tributaries to be managed with Enhanced Working Mode

X X

3.2 Fault Management/Maintenance/Monitoring

Disable Dynamic Modulation procedure in case of Controller HW failure

X X

"Hard" switch in case of Dynamic Modulation protocol failure

X X

“Local AIS insertion on half payload” alarm (Normal Working Mode)

X X

Parallel alarms restitution (system summarized alarms)

X X X X X X X X

Station alarms collection X X X X X X X X

Station alarm remotization (output via front-panel HW contacts)

X X X X X X X X

SW Change of external alarms polarity (normally closed or normally open) for each alarm

X X X X

Configurable severity of input station alarms X X

Alarm (summarised & detailed) reporting and collection

X X X X X X X X

17 Available on frequencies ≥ 18 GHz; available on frequencies ≥ 13 GHz starting from SVR 3.10 SU1.

18 X up to 3 dB. Please note ATPC boost is available with dynamic modulation licence.

PAGE 11

IPT MWR Product Management

3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10

Alarm activation for ODU Stand-by on X X

“Over Temperature” Alarm of the IDU19

X

Protection Switches forcing X X X X X X X X

Automatic Storage of last 12 events for each slave X X X X X X X X

Tributary loop back at 2 Mbit/s level (Local & Remote)

X X X X X X X X

Auto-Test capability (final test / maintenance purpose)

X X X X X X X X

Outdoor unit power-up and power-down X X X X X X X X

Status control (each card/unit) (Dis. – Con. – OnL. – Mis.)

X X X X X X X X

(1+1) FD channel static delay (setting & reading)

X X X X X X X X

(1+1) FD channel dynamic delay (reading) X X X X X X X X

Early Warning Indication (1+1 FD only) X X X X X X X X

All Card Hot Replacement X X X X X X X X

Local / Remote Controller reset X X X X X X X X

Line automatic switch periodic20

: -Up to 15minutes -Logic protection active (come back to the other line in case of failure)

X X

X X

X X

X X

X X

Enable/Disable AIS in/out X X X

3.3 Measures

Received Field X X X X X X X X

ODU internal temperature X X X X X X X X

ODU Transmitted Power21

X X X X X

IDU internal temperature22

X X X

3.4 Performance Monitoring

G.826/G.828 parameters calculation X X X X X X X X

Radio power Parameters (RSPI, Rx Thr. only)

X X X X X X X

Radio power Parameters (RSPI, Rx Thr.&Tx Thr)23

X X X X X

G.826 data transfer via XML X X X X X X X

3.5 Inventory Data

HW data X X X X X X X X

User data X X X X X X X X

19 On IDU Plug-In 32xE1 with 16xE1+3xFE+1xGE Access unit and Controller with fans

20 Not supported in conjunction with Dynamic Modulation feature enabled

21 Not supported by ODU ND

22 Available starting from a specific HW version of Controller Card of IDU Plug-in (634-001/74, minimum HW

edition=8) 23

Not supported by ODU ND

PAGE 12

IPT MWR Product Management

3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10

Software data X X X X X X X X

3.6 User Fee Management

Dynamic Modulation licence enabled

X X

Licence fee management X X X X X X X X

Memory key management (Faulty IDU replacement)

X X X X X X X X

OSPF licence fee management X X X

3.7 Commissioning facilities

Performance recording into NE (last 192 x 1/4 hour)

X X X X X

Local History Log on NE X X X X X X

NetViewer HLog Realignment Support X X X X X X

Line automatic switch (1+1 configuration)24

X X X X X

Remote Temporary TX Switch-Off X X X X X X X X

3.8 Security management

Accounting log: -Circular file with 120 entries -Access via admin FTP only -feature enable/disable

X X X

X X X

X X X

X X X

IP ports enable/disable (except for FTP) X

IP ports (including FTP) enable/disable: Default enabled for FTP

X X X

Same password for FTP and TNMP sessions X X X

SSH/SFTP (FTP and Telnet) X

4 TMN OPTIONS

4.1 TMN Facilities

Automatic up-dating of TCP-IP routing tables RIP v.1 X X X X X X X X

Automatic up-dating of TCP-IP routing tables OSPF (RIP disabled)

X X X

NAPT protocol over F interface X X X

Routing Table FTP Accessibility X X X X X X X X

Agent TNMP X X X X X X X X

Zero Forcing of RIP metric X X X X X X X X

Border Gateway Functionalities X X X X X X X X

SNTP agent (system clock update) X X X X

24 Not supported in conjunction with Dynamic Modulation feature enabled

PAGE 13

IPT MWR Product Management

3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10

4.1 Network Management System

Autodiscovery (IP Address – Channel ID) X X X X X X

Enable/Disable Alarm Severity sending X X X X X X

Remote NEs supervision via NetViewer X X X X X X X X

Local Network Element supervision via LinkViewer X X X X X X X X

Remote NEs supervision via NetViewer NME X X X X X X X X

Configurable Priority on LCT connection

X X X

4.2 Network upgrade

Temporized Command procedure for Firmware/Software upgrade

X

5 SOFTWARE DOWNLOAD

Local SW downloading (via LinkViewer) X X X X X X X X

Remote SW downloading (via NetViewer) X X X X X X X X

SW bank switch X X X X X X X X

SW bank copy X X X X X X X X

ODU Software Download Recovery Procedure X X X X X X

PAGE 14

IPT MWR Product Management

3.2 SRAL XD SINGLE BOARD VERSION

4.3 4.4

1.1 Capacities

2/4/8/16xE1 X X

1.2 Outdoor Unit

ODU HDe25

X

ODU HD/HP26

X X

ODU ND X X

ODU ND2 X

1.3 Indoor Unit

(1+0) 8E1 X X

(1+1) 8E1 X X

(1+0) 16E1 X X

(1+1) 16E1 X X

1.4 Service Facilities

Voice Service Channel via IP on a single link (IP telephone/Netmeeting)

X X

10/100 BaseT NMS channel (Q Ch) X X

10BaseT NMS channel (V Ch) X X

64 Kbit/s V.11 selectable as -NMS Channel (Dext Ch) or -User Channel

X X

64 Kbit/s Embedded NMS Channel (D embedded Ch) (1x)

X X

Interworking over F Interface X

F interface RS-232 (LCT) X X

Standard IP protocol stack over NMS channels

X X

2 CONFIGURATIONS

(1+0) Terminal X X

(1+1) Hot Stand-by X X

3 FEATURES

25 ODU HDe is able to perform both Normal density and High density channel arrangement. Supported

capacities are 4/8/16xE1. Due to HW constraints, High density arrangement is available on 8E1 and 16E1 26

ODU HD/HP is able to perform both Normal density and High density channel arrangement. Due to HW constraints, High density arrangement is available on 8E1 and 16E1 only.

PAGE 15

IPT MWR Product Management

4.3 4.4

3.1 Configuration management

Spectrum efficiency selection (ND/HD) X X

Tx/Rx frequency selection X X

Tx and Rx Freq.Range Display X X

RF channel management: Frequency plan

27

Continuous mode

X X

X X

Tx output power selection mode (fixed, ATPC)

X

Tx output power setting (fixed mode) X X

Capacity selection (NxE1) X X

2 Mb/s tributary lines disabling/enabling X X

System activation (on/off) (TX squelch) X X

Dembedded Channel enabling/disabling X X

Dembedded Ch Drop/insert & Time Slot assignment

X X

64Kbit/s User Channel mode selection (co/contra-directional)

X X

Automatic F Interface configuration between LCT or NMS channel

X

NMS channel protocol stack selection (SRA L like / standard IP stack)

X X

Security enabling/disabling via password X X

Link identification code X X

NE IP Address and net mask configuration

X X

Modulation index setting (BW 99% adaptation)

28

X X

3.3 Fault

Management/Maintenance/Monitoring

Parallel alarms restitution (system summarized alarms)

X X

Station alarms collection X X

Alarm (summarised & detailed) reporting and collection

X X

Protection Switches forcing X X

Automatic Storage of last 12 events for each slave

X X

Tributary loop back at 2 Mbit/s level (Local & Remote)

X X

Auto-Test capability (final test / maintenace purpose)

X X

Outdoor unit power-up and power-down X X

27

Channel spacing: 3.5, 7, 14 (13.75), 28 (27.5) MHz for Normal Density arrangement; 7, 14 (13.75) MHz for High Density arrangement. 28

Available with ODU ND only

PAGE 16

IPT MWR Product Management

4.3 4.4

Status control (each card/unit) (Dis. – Con. – OnL. – Mis.)

X X

Local / Remote Controller reset X X

3.4 Measures

Received Field X X

ODU internal temperature X X

3.5 Performance Monitoring

G.826/G.828 parameters calculation X X

Radio power Parameters (RSPI, Rx Thr. only)

X

G.826 data transfer via XML X

3.6 Inventory Data

HW data X X

User data X X

Software data X X

3.7 User Fee Management

Licence fee management X X

Memory key management (Faulty IDU replacement)

X X

3.8 Commissioning facilities

Remote Temporary TX Switch-Off X X

4 TMN OPTIONS

4.1 TMN Facilities

Automatic up-dating of TCP-IP routing tables RIP v.1

X X

Agent TNMP X X

4.1 Network Management System

Remote NEs supervision via NetViewer X X

Local Network Element supervision via LinkViewer

X X

Remote NEs supervision via NetViewer NME

X X

5 SOFTWARE DOWNLOAD

Local SW downloading (via LinkViewer) X X

PAGE 17

IPT MWR Product Management

4.3 4.4

Remote SW downloading (via NetViewer) X X

SW bank switch X X

SW bank copy X X

Manual ODU Software Download Recovery Procedure

X

3.3 SRAL XD SINGLE BOARD2 VERSION

IDU SB2 7.5 7.7

1 Managed Capacities

1.1 2/4/8xE1 on air X X

1.2 2/4/8/16xE1 on air X

2 Tributary interfaces: physical

2.1 8/16xE1 G.703 75/120 Ohm with SubD 50pin connector

X X

3 IDU HW versions

3.2 (1+0) 8E1 X X

3.3 (1+0) 16E1 X

3.4 (1+1) 16E1 X

4 Supported Outdoor Unit

4.1 ODU HD/HP X X

4.2 ODU HDe X X

4.3 ODU ND/ND2 X X

5 Service channels

5.1 Voice Service Channel via IP on a single link (IP telephone/Netmeeting)

X X

5.2 R-Channel (64kbit/s out-of-band channel) X X

5.3 1x64 Kbit/s V.11 selectable as Dext Channel or User Channel

X X

5.4 2x10/100 BaseT NMS channel (Q/VCh) X X

5.5 64 Kbit/s Embedded NMS Channel (D embedded Ch)

X X

5.6 F Interface for Local Craft Terminal29

X X

5.7 Interworking over F interface X X

5.8 Interworking over F Interface within same SubNet (LAN Disabling)

X X

29 RS-232 interface

PAGE 18

IPT MWR Product Management

IDU SB2 7.5 7.7

5.9 Standard IP protocol stack over NMS channels X X

6 Supported system types

6.1 (1+0) Terminal X X

6.2 (1+1) Hot Stand-by Terminal X

7 Configuration management features

7.1 Spectrum efficiency selection (ND/HD) X X

7.2 Tx/Rx frequency selection X X

7.3 Tx and Rx Freq.Range Display X X

7.4 RF channel management: Frequency plan

30

Continuous mode

X X

X X

7.5 Tx output power selection mode (fixed, ATPC)

X X

7.6 Tx output power setting (fixed mode) X X

7.7 Capacity selection (NxE1) X X

7.8 2 Mb/s tributary lines disabling/enabling X X

7.9 System activation (on/off) (TX squelch) X X

7.10 Dembedded Channel enabling/disabling X X

7.11 Dembedded Ch Drop/insert & Time Slot assignment X X

7.12 64Kbit/s User Channel mode selection (co/contra-directional)

X X

7.13 NMS channel protocol stack selection (SRA L like / standard IP stack)

X X

7.14 Security enabling/disabling via password X X

7.15 Link identification code X X

7.16 NE IP Address and net mask configuration X

7.17 Modulation index setting (BW 99% adaptation)

31

X X

7.18 MTU setting X X

7.19 Automatic F Interface configuration between LCT or NMS channel

X X

7.20 F interface configuration between LCT or LCT/NMS channel

X X

7.21 Frequency Self-alignment in 1+1 configuration X

8 Fault Management/Maintenance/monitoring

features

8.1 Parallel alarms restitution via LED AND open-ground criteria (system summarized alarms)

X X

30

Channel spacing: 3.5, 7, 14 (13.75), 28 (27.5) MHz for Normal Density arrangement; 7, 14 (13.75) MHz for High Density arrangement. 31

Available with ODU ND family only

PAGE 19

IPT MWR Product Management

IDU SB2 7.5 7.7

8.3 Alarms (summarised & detailed) reporting and collection to Element Manager

X X

8.4 Automatic Storage of last 12 events X X

8.5 Tributary loop back at 2 Mbit/s level (Local & Remote)

X X

8.6 Auto-Test capability (final test / maintenance purpose)

X X

8.7 ODU unit power-up and power-down X X

8.8 Status control (each card/unit) (Dis. – Con. – OnL. – Mis.)

X X

8.9 Local / Remote Controller reset X X

8.10 HW Mismatch alarm transparent management X X

8.11 Protection Switches forcing X

8.12 Line automatic switch periodic: -Up to 15minutes -Logic protection active

X

8.13 AIS Alarm enable/disable X

9 Measures

9.1 Received Field X X

9.2 ODU internal temperature X X

9.3 ODU Transmitted Power32

X

10 Performance Monitoring

10.1 G.826/G.828 parameters calculation X X

10.2 Radio power Parameters (RSPI Rx Thr.) X X

10.3 PM data transfer via XML X X

10.5 Radio power Parameters (RSPI, Rx Thr.&Tx Thr33

) X

11 Inventory Data

11.1 HW data X X

11.2 User data X X

11.3 Software data X X

12 User Fee Management

12.1 Licence fee management X X

12.2 Memory key management (Faulty IDU replacement)

X X

13 Commissioning facilities

13.1 Performance recording into NE (last 192 x 1/4 X

32 Not supported by ODU ND

33 Not supported by ODU ND

PAGE 20

IPT MWR Product Management

IDU SB2 7.5 7.7

hour)34

13.2 Local History Log on NE X X

13.3 NetViewer HLog Realignment Support X X

13.4 Remote Temporary TX Switch-Off X X

13.5 Line automatic switch single sequence X

14 TMN OPTIONS

14.1 Automatic up-dating of IP routing tables RIP v.1 X X

14.2 Routing Table FTP Accessibility X X

14.3 Agent TNMP X X

14.4 Zero Forcing of RIP metric X X

14.5 Border Gateway Functionalities X X

14.6 Autodiscovery (IP Address – Channel ID) X X

14.7 Enable/Disable Alarm Severity sending X X

14.8 Remote NEs supervision via NetViewer X X

14.9 Local Network Element supervision via LinkViewer X X

14.10 Remote NEs supervision via NetViewer NME X X

14.11 SNTP agent (system clock update) X

15 SOFTWARE DOWNLOAD

15.1 Local SW downloading (via LinkViewer) X X

15.2 Remote SW downloading (via NetViewer) X X

15.3 SW bank switch X X

15.4 SW bank copy X X

15.5 Manual ODU Software Download Recovery Procedure

X X

16 Hw compatibility

16.1 Mixed radio link with SRAL XD IDU family (Plug-in, Single Board, Fully Outdoor, TwoE1)

X X

17 Accessories

17.1 Single Brackets couple for N3/19” rack X X

34 Automatic commissioning features

PAGE 21

IPT MWR Product Management

3.4 SRAL XD TWOE1 VERSION

1.3

1.1 Capacities

1/2xE1 X

1.2 Outdoor Unit

ODU ND X

1.3 Indoor Unit

(1+0) 2E1 X

1.4 Service Facilities

Voice Service Channel via IP on a single link (IP telephone/Netmeeting)

X

10/100 BaseT NMS channel (Q Ch) X

10BaseT NMS channel (V Ch) X

64 Kbit/s V.11 selectable as -NMS Channel (Dext Ch) or -User Channel

X

64 Kbit/s Embedded NMS Channel (D embedded Ch) (1x)

X

F interface RS-232 (LCT) X

Standard IP protocol stack over NMS channels

X

2 CONFIGURATIONS

(1+0) Terminal X

3 FEATURES

3.1 Configuration management

Tx/Rx frequency selection X

Tx and Rx Freq.Range Display X

RF channel management: Frequency plan

35

Continuous mode

X X

Tx output power setting (fixed mode) X

Capacity selection (1/2xE1) X

2 Mb/s tributary lines disabling/enabling X

System activation (on/off) (TX squelch) X

Dembedded Channel enabling/disabling X

35

Channel spacing: 3.5 MHz

PAGE 22

IPT MWR Product Management

1.3

Dembedded Ch Drop/insert & Time Slot assignment

X

64Kbit/s User Channel mode selection (co/contra-directional)

X

NMS channel protocol stack selection (SRA L like / standard IP stack)

X

Security enabling/disabling via password X

Link identification code X

NE IP Address and net mask configuration

X

Modulation index setting (BW 99% adaptation)

X

3.3 Fault

Management/Maintenance/Monitoring

Parallel alarms restitution (system summarized alarms)

X

Station alarms collection X

Alarm (summarised & detailed) reporting and collection

X

Protection Switches forcing X

Automatic Storage of last 12 events for each slave

X

Tributary loop back at 2 Mbit/s level (Local & Remote)

X

Auto-Test capability (final test / maintenace purpose)

X

Outdoor unit power-up and power-down X

Status control (each card/unit) (Dis. – Con. – OnL. – Mis.)

X

Local / Remote Controller reset X

3.4 Measures

Received Field X

ODU internal temperature X

3.5 Performance Monitoring

G.826/G.828 parameters calculation X

3.6 Inventory Data

HW data X

User data X

Software data X

3.7 User Fee Management

Licence fee management X

PAGE 23

IPT MWR Product Management

1.3

Memory key management (Faulty IDU replacement)

X

3.8 Commissioning facilities

Remote Temporary TX Switch-Off X

4 TMN OPTIONS

4.1 TMN Facilities

Automatic up-dating of TCP-IP routing tables RIP v.1

X

Agent TNMP X

4.1 Network Management System

Remote NEs supervision via NetViewer X

Local Network Element supervision via LinkViewer

X

Remote NEs supervision via NetViewer NME

X

5 SOFTWARE DOWNLOAD

Local SW downloading (via LinkViewer) X

Remote SW downloading (via NetViewer) X

SW bank switch X

SW bank copy X

PAGE 24

IPT MWR Product Management

3.5 SRAL XD OUTDOOR ACCESS UNIT (FULLY OUTDOOR) VERSION

SVR

2.5

1.1 Capacities

1.1.1 2/4/8xE1 X

1.2 Outdoor Unit

1.2.1 ODU HD/HP36

X

1.2.2 ODU ND/ND2 X

1.2.3 ODU HDe 37

X

1.3 Power Supply

1.3.1 DC/DC version X

1.3.2 AC/DC version X

1.3.3 AC/DC version with Back-up batteries (up to 30minutes) X

1.4 Indoor Unit cards

1.4.1 (1+0) 8E1 X

1.5 Service Facilities

1.5.1 R-Channel (64kbit/s out-of-band channel) X

1.5.2 10/100 BaseT NMS channel (Q Ch) X

1.5.3 64 Kbit/s Embedded NMS Channel (D embedded Ch) (1x)

X

1.5.4 F Interface RS-232 (LCT) X

1.5.5 Interworking over F Interface X

1.5.6 Interworking over F Interface within same SubNet (LAN Disabling)

X

1.5.7 Standard IP protocol stack over NMS channels X

2 CONFIGURATIONS

2.1 (1+0) Terminal X

2.2 E1 75/120 ohm (selectable via proper cabling) X

3 FEATURES

3.1 Configuration management

3.1.1 Spectrum efficiency selection (ND/HD) X

36

ODU HD/HP is able to perform both Normal density and High density channel arrangement. Supported capacities are 2/4/8xE1.Due to HW constraints, High density arrangement is available on 8E1 only 37 ODU HDe is able to perform both Normal density and High density channel arrangement. Supported

capacities are 4/8xE1. Due to HW constraints, High density arrangement is available on 8E1 only

PAGE 25

IPT MWR Product Management

SVR

2.5

3.1.2 Tx/Rx frequency selection X

3.1.3 Tx and Rx Freq.Range Display X

3.1.4 RF channel management: Frequency plan

38

Continuous mode

X X

3.1.5 Tx output power selection mode (fixed, ATPC)

X

3.1.6 Tx output power setting (fixed mode) X

3.1.7 Capacity selection (NxE1) X

3.1.8 2 Mb/s tributary lines disabling/enabling X

3.1.9 System activation (on/off) (TX squelch) X

3.1.10 Dembedded Channel enabling/disabling X

3.1.11 Dembedded Ch Drop/insert & Time Slot assignment X

3.1.12 Automatic F Interface configuration between LCT or NMS channel

X

3.1.13 F interface configuration between LCT or LCT/NMS channel X

3.1.14 NMS channel protocol stack selection (SRA L like / standard IP stack)

X

3.1.15 MTU Setting X

3.1.16 Security enabling/disabling via password X

3.1.17 Link identification code X

3.1.18 NE IP Address and net mask configuration X

3.1.19 Modulation index setting (BW 99% adaptation)

39

X

3.2 SRA L& SRAL XD interoperability

3.2.1

Mixed link SRA L Universal /SRAL XD ND (on air)

X

3.2.2 Mixed link SRAL XD Fully Outdoor (OAU)/SRAL XD with Single Board or Plug-in IDU X

3.3 Fault Management/Maintenance/Monitoring

3.3.1 Parallel alarms restitution via LED and HW contacts (system summarized alarms)

X

3.3.2 Station alarms collection/remotisation X

3.3.3 Alarm (summarised & detailed) reporting and collection

X

3.3.4 Automatic Storage of last 12 events for each slave X

3.3.5 Tributary loop back at 2 Mbit/s level (Local & Remote)

X

3.3.6 Auto-Test capability (final test / maintenace purpose)

X

38

Channel spacing: 3.5, 7, 14 (13.75) MHz for Normal Density arrangement; 7 MHz for High Density arrangement. 39

Available with ODU ND only

PAGE 26

IPT MWR Product Management

SVR

2.5

3.3.7 Outdoor unit power-up and power-down X

3.3.8 Status control (each card/unit) (Dis. – Con. – OnL. – Mis.)

X

3.3.9 Local / Remote Controller reset X

3.3.10 HW Mismatch alarm transparent management X

3.4 Measures

3.4.1 Received Field X

3.4.2 ODU internal temperature X

3.4.3 Tx output power40

X

3.5 Performance Monitoring

3.5.1 G.826/G.828 parameters calculation X

3.5.2 Radio power Parameters (RSPI, Rx Thr. only) X

3.5.3 PM data transfer via XML X

3.6 Inventory Data

3.6.1 HW data X

3.6.2 User data X

3.6.3 Software data X

3.7 User Fee Management

3.7.1 Licence fee management X

3.7.2 Memory key management (Faulty IDU replacement)

X

3.8 Commissioning facilities

3.8.1 Local History Log on NE X

3.8.2 NetViewer HLog Realignment Support X

3.8.3 Remote Temporary TX Switch-Off X

4 TMN OPTIONS

4.1 Automatic up-dating of TCP-IP routing tables RIP v.1 X

4.2 Routing Table FTP Accessibility X

4.3 Agent TNMP X

4.4 Zero Forcing of RIP metric X

4.5 Border Gateway Functionalities X

4.6 Autodiscovery (IP Address – Channel ID) X

4.7 Enable/Disable Alarm Severity sending X

40 Available with ODU HD/HP and ODU HDe only

PAGE 27

IPT MWR Product Management

SVR

2.5

4.8 Remote NEs supervision via NetViewer X

4.9 Local Network Element supervision via LinkViewer X

4.10 Remote NEs supervision via NetViewer NME X

5 SOFTWARE DOWNLOAD

5.1 Local SW downloading (via LinkViewer) X

5.2 Remote SW downloading (via NetViewer) X

5.3 SW bank switch X

5.4 SW bank copy X

5.5 Manual ODU Software Download Recovery Procedure X