1
Square L-Shaped PermaWrap ® Column Installation Instructions TEMPERATURE RELATED ISSUES: PVC Columns become more brittle in colder temperatures. When the columns become more brittle, they are more susceptible to damage. It is recommended that the columns themselves be warmed to 50° to 55° before installing. This can be accomplished by moving the columns into a heated space, and allowing adequate time for the temperature of the columns to warm up. The out- door ambient temperature can be considerably colder than 50°, but if the columns themselves can be warmed up, they can then be installed with reduced risk of damaging them in the process. If you are unable to warm the columns before installation, you should first drill pilot holes before screwing or nailing them together. Be careful when nailing the columns and try to avoid striking the column faces with a hammer. Note that if your particular columns are designed in such a way that they include miter folded corners, which have not been folded, closed, they will definitely be susceptible to fracture if they cannot be warmed. If a miter-folded corner does fracture, you will still have a good miter joint, which consists of (2) separate pieces. CUTTING AND FASTENING: The Cellular PVC material that the columns are constructed of can easily be cut with conventional carpentry and woodworking tools. Pneumatic finish nailers and staplers can be used to fasten Cellular PVC parts together. Large pneumatic framing staplers and nailers are not suitable for fas- tening this material as the percussion of the drivers of large nail guns can fracture the PVC materi- al. Coarse thread, galvanized or stainless steel drywall screws are also suitable for fastening Cellular PVC parts together. It is suggested that pilot holes be used for screws longer than 1 5/8". PAINTING AND FINISHING: Caulk where required using Siroflex brand Sealant and Adhesive provided by manufacturer. Putty any holes using acrylic putty or caulk. Lightly sand or scuff surface of column. Clean surface of column to remove any dirt or hand oil residue with light detergent and water, denatured alcohol, or window cleaner. Be sure to remove soap residue with clean water. Apply one coat of 100% acrylic exterior primer and one or more finish coats of 100% acrylic exterior paint. Do not paint columns using dark colors (dark colors are considered any color that falls within the L value of 56 to 0). L is the meas- ure of lightness of an object and ranges from 0 (black) to 100 (white). Do not install below grade. THE PVC COLUMN HAS NO TESTED STRUCTURAL PROPERTIES. The column is designed to install around a previously installed structural post. The structural post inside column, supplied by others, provides the load-bearing component of the column. The load-bearing capacity of column is determined by the physical properties of the structural post. The architect or engineer will specify load-bearing requirements of the structural post. Structural post must be of ACQ, CCA or other treated lumber, ACQ, CCA or other treated engineered lumber, or steel. DO NOT USE UNTREATED LUMBER FOR STRUCTURAL POSTS. Possible infiltration of water and possible condensation inside the PVC column shaft can cause degradation of untreated lumber! Bottom of structural post should be mounted to wooden deck or concrete/mason- ry porch floor using code-approved method and code approved post anchor. Top of structural post should be mounted to beam using code- approved method and code approved post-to-beam mounting bracket. 1. CUT THE COUMN TO THE DESIRED LENGTH. THIS CAN BE DONE USING A SKILL SAW OR JIG SAW. 2. FASTEN THE 5” X 3-1/2” PVC MOUNT- ING BLOCKS TO THE 4” X 4” POST SO THE COLUMN WILL BE CENTERED AROUND THE POST. BE SURE TO ATTACH AT LEAST 2 BLOCKS TO THE 4” X 4” AT THE TOP, AND 2 -AT THE BOTTOM. IF A HANDRAIL IS GOING TO BE ATTACHED, ADD BLOCKS TO THE 4” X 4” WHERE THE RAIL MOUNTING WILL TAKE PLACE. 3. INSTALL ONE L-SHAPED HALF AROUND THE 4” X 4” POST AND FASTEN THROUGH THE FACES OF THE COLUMN HALF INTO THE MOUNTING BLOCKS. YOU MAY FASTEN INTO THE FACES OR THE ENDS OF THE MOUNTING BLOCKS. 3. INSTALE UNA DE LAS SEC- CIONES DE COLUMNA EN FORMA DE “L” ALREDEDOR DEL POSTE DE 4” X 4” Y ASEGÚRELA A ESTE. UD PUEDE ANCLARSE A LA CARA O AL COSTADO DE LAS PIEZAS PROVIS- TAS. 2. CLAVE LAS PIEZAS DE PVC DE 5” X 3-1/2” AL POSTE DE 4X4 DE TAL MANERA QUE LA COLUMNA QUEDE CENTRADA ALREDEDOR DEL POSTE. ASEGÚRESE DE CLAVAR POR LO MENOS 2 DE ELLOS EN LA PARTE SUPERIOR Y OTROS 2 EN LA PARTE INFERIOR DEL POSTE DE 4X4, SI SE PIENSA INSTALAR PASAMANOS, INSTÁLE- LOS TAMBIÉN A LA ALTURA REQUERIDA. 5. SLIDE THE 2ND L-SHAPED COLUMN HALF IN PLACE AND PUSH THE MITERED EDGES TOGETHER. SCREW TOP AND BOTTOM OF THE COLUMN SHAFT INTO THE TOP & BOTTOM SQUARING BLOCKS. FASTEN THE COLUMN ALONG BOTH EDGES AS WELL AS ATTACHING IT TO THE SQUARING BLOCKS. WE RECOMMEND FAS- TENING THE COLUMN EVERY 6 TO 8 INCHES USING 1-1/4” STA- PLES. FINISH NAILS WORK ALSO. WIPE OFF ANY ADHESIVE CAULK SQUEEZE-OUT WITH DAMP CLOTH. THE ADHESIVE CAULK CLEANS UP WITH WATER. IT IS IMPORTANT TO WIPE OFF THE EXCESS ADHESIVE CAULK BEFORE IT DRIES! 6. ATTACH THE BASE AND CAP COLLARS TO THE COLUMN SHAFT. APPLY ADHESIVE TO THE MITERED EDGES & WRAP THE COLLARS AROUND THE SHAFT AT THE TOP AND BOTTOM. FASTEN THE COLLARS TO THE SHAFT AND FASTNEN BOTH HALVES TOGETHER AT THE CORNERS. WIPE OFF ANY ADHESIVE SQUEEZE-OUT WITH DAMP CLOTH. THE ADHESIVE CLEANS UP WITH WATER. IT IS IMPORTANT TO WIPE OFF THE EXCESS ADHESIVE BEFORE IT DRIES! USE THE ADHESIVE CAULK TO CAULK THE SMALL GAP BETWEEN THE BACK OF THE COLLARS AND THE COLUMN SHAFT. 4. APPLY ADHESIVE CAULK TO THE 2 MITERED EDGES OF THE L-SHAPED COLUMN SHAFT. LA COLUMNA DE PVC CARECE DE PROPIEDADES AUTOPOR- TANTES. La columna esta diseñada para ser instalada alrededor de un poste estructural existente. El poste estructural al interior de la colum- na, y suministrado por terceros, representa la característica estructur- al. La capacidad autoportante de la columna esta determinada por las características físicas del poste. El Arquitecto o el Ingeniero se encar- garán de especificar los requerimientos estructurales del poste. El poste estructural debe ser ACQ, CCA o de otra madera inmunizada, ACQ, CCA, o de un elemento de madera reforzada e inmunizada o de acero. NO USE MADERA SIN INMUNIZAR COMO POSTES ESTRUC- TURALES, ya que esta puede ser afectada por infiltraciones de agua o condensaciones dentro de la columna. El poste se debe asegurar al suelo y a la viga usando solamente métodos y anclajes aprobados por el código de construcción. ASPECTOS RELACIONADOS CON LA TEMPERATURA: Las columnas de PVC se tornan más frágiles al ser expuestas a bajas temperaturas siendo más susceptibles al daño. Se recomienda ambientar las columnas a una temperatura de 50 o 55 grados antes de instalarlas. Esto se puede lograr llevando las columnas a un lugar con calefacción y permitir que suba la temperatura de las columnas. Aunque la temperatura exterior sea bastante inferior a 50 grados, las columnas se pueden instalar si han sido previamente ambientadas reduciendo de esta manera la posibilidad de causarles daño. Si no es posible ambientar las columnas antes de instalarlas, UD deberá hacer unas perforaciones ini- ciales con una broca pequeña antes de usar tornillos o puntillas para el ensamblaje. Tenga cuida- do al usar puntillas de no golpear las columnas con el martillo. Tenga presente que si las columnas tienen esquinas que no han sido previamente dobladas, es posible que se quiebren si no han sido ambientadas. En caso de que esto suceda, Ud. de todos modos tendrá 2 cuerpos con esquinas bien definidas. CORTES Y ASEGURAMIENTO El material de PVC usado para fabricar las columnas puede ser fácilmente cortado con herramien- tas convencionales de carpintería o ebanistería. Para ensamblar las columnas utilice pistolas pequeñas de aire para puntillas o grapas. Las pistolas grandes pueden ocasionar daño debido la percusión que generan. Tornillos de rosca ancha y grapas galvanizadas o inoxidables para “Sheet Rock” también son recomendadas. PINTURA Y ACABADO Macille cuando sea necesario usando el pegante suministrado por el fabricante. Rellene los huecos usando macilla acrílica. Suavemente lije y empareje la superficie de la columna. Use un detergente liviano y agua, alcohol natural o limpiador de vidrios para limpiar el mugre o residuos de aceite. Asegúrese de remover residuos de jabón con agua limpia. Aplique una capa de base 100% acríli- ca y una o más capas de pintura para exteriores100% acrílica. No pintar las columnas con los col- ores oscuros (los colores oscuros son considerados de cualquier color que se encuentre dentro del valor de L de 56 a 0). L es la medida de luminosidad de un objeto y va de 0 (negro) a 100 (blanco). No instale por debajo del nivel. Instrucciones de Instalacion para Columna Cuadrada PermaWrap ® 6. SITUE LOS COLLARES ALREDEDOR DE LA COLUMNA APLICANDO PEGANTE EN LOS BORDES EN ANGULO. ASEGURE AMBAS A LA COLUMNA Y ENTRE ELLAS MISMAS LIMPIANDO EL PEGANTE AL FINALIZAR CON UN TRAPO HUMEDO. USE EL MISMO PEGANTE PARA SELLAR LOS ESPACIOS ENTRE LA COLUMNA Y LOS COLLARES. 4. APLIQUE EL PEGANTE A LOS BORDES DE UNA DE LAS SEC- CIONES EN “L”. 1. CORTE LA COLUMNA A LA DISTANCIA QUE NECESITE USANDO UNA SIERRA MANUAL O UNA ELECTRICA. 5. POSICIONE LA OTRA SECCIÓN EN FORMA DE “L” Y ATORNILLE LA COLUMNA A LAS ESCUADRAS INTERNAS TANTO ARRIBA COMO ABAJO Y VERTICALMENTE A LO LARGO DE LAS UNIONES CADA 6 U 8 INCHES USANDO GRAPAS DE 1-1/4” O PUNTILLAS PARA ACABA- DO. LIMPIE CON UNA TOALLA HÚMEDA LOS EXCESOS DE PEGANTE ANTES DE QUE SE ENDUREZCAN.

Square L-Shaped PermaWrap Instrucciones de Instalacion

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Square L-Shaped PermaWrap Instrucciones de Instalacion

Square L-Shaped PermaWrap®

Column Installation Instructions

TEMPERATURE RELATED ISSUES:PVC Columns become more brittle in colder temperatures. Whenthe columns become more brittle, they are more susceptible todamage. It is recommended that the columns themselves bewarmed to 50° to 55° before installing. This can be accomplished by moving the columns into aheated space, and allowing adequate time for the temperature of the columns to warm up. The out-door ambient temperature can be considerably colder than 50°, but if the columns themselves canbe warmed up, they can then be installed with reduced risk of damaging them in the process. If youare unable to warm the columns before installation, you should first drill pilot holes before screwingor nailing them together. Be careful when nailing the columns and try to avoid striking the columnfaces with a hammer. Note that if your particular columns are designed in such a way that theyinclude miter folded corners, which have not been folded, closed, they will definitely be susceptibleto fracture if they cannot be warmed. If a miter-folded corner does fracture, you will still have a goodmiter joint, which consists of (2) separate pieces.

CUTTING AND FASTENING:The Cellular PVC material that the columns are constructed of can easily be cut with conventionalcarpentry and woodworking tools. Pneumatic finish nailers and staplers can be used to fastenCellular PVC parts together. Large pneumatic framing staplers and nailers are not suitable for fas-tening this material as the percussion of the drivers of large nail guns can fracture the PVC materi-al. Coarse thread, galvanized or stainless steel drywall screws are also suitable for fastening CellularPVC parts together. It is suggested that pilot holes be used for screws longer than 1 5/8".

PAINTING AND FINISHING:Caulk where required using Siroflex brand Sealant and Adhesive provided by manufacturer. Putty anyholes using acrylic putty or caulk. Lightly sand or scuff surface of column. Clean surface of columnto remove any dirt or hand oil residue with light detergent and water, denatured alcohol, or windowcleaner. Be sure to remove soap residue with clean water. Apply one coat of 100% acrylic exteriorprimer and one or more finish coats of 100% acrylic exterior paint. Do not paint columns using darkcolors (dark colors are considered any color that falls within the L value of 56 to 0). L is the meas-ure of lightness of an object and ranges from 0 (black) to 100 (white).

Do not install below grade.

THE PVC COLUMN HAS NO TESTED STRUCTURAL PROPERTIES. Thecolumn is designed to install around a previously installed structuralpost. The structural post inside column, supplied by others, providesthe load-bearing component of the column. The load-bearing capacityof column is determined by the physical properties of the structuralpost. The architect or engineer will specify load-bearing requirementsof the structural post. Structural post must be of ACQ, CCA or othertreated lumber, ACQ, CCA or other treated engineered lumber, or steel.DO NOT USE UNTREATED LUMBER FOR STRUCTURAL POSTS.Possible infiltration of water and possible condensation inside the PVCcolumn shaft can cause degradation of untreated lumber! Bottom ofstructural post should be mounted to wooden deck or concrete/mason-ry porch floor using code-approved method and code approved postanchor. Top of structural post should be mounted to beam using code-approved method and code approved post-to-beam mounting bracket.

1. CUT THE COUMN TO THE DESIRED LENGTH. THIS CAN BE DONE USING A SKILL SAW OR JIG SAW.

2. FASTEN THE 5” X 3-1/2” PVC MOUNT-ING BLOCKS TO THE 4” X 4” POST SO THECOLUMN WILL BE CENTERED AROUNDTHE POST. BE SURE TO ATTACH AT LEAST2 BLOCKS TO THE 4” X 4” AT THE TOP, AND2 -AT THE BOTTOM. IF A HANDRAIL ISGOING TO BE ATTACHED, ADD BLOCKS TOTHE 4” X 4” WHERE THE RAIL MOUNTINGWILL TAKE PLACE.

3. INSTALL ONE L-SHAPED HALFAROUND THE 4” X 4” POST ANDFASTEN THROUGH THE FACESOF THE COLUMN HALF INTO THEMOUNTING BLOCKS. YOU MAYFASTEN INTO THE FACES OR THEENDS OF THE MOUNTINGBLOCKS.

3. INSTALE UNA DE LAS SEC-CIONES DE COLUMNA EN FORMADE “L” ALREDEDOR DEL POSTE DE4” X 4” Y ASEGÚRELA A ESTE. UDPUEDE ANCLARSE A LA CARA O ALCOSTADO DE LAS PIEZAS PROVIS-TAS.

2. CLAVE LAS PIEZAS DE PVC DE 5” X 3-1/2” ALPOSTE DE 4X4 DE TAL MANERA QUE LACOLUMNA QUEDE CENTRADA ALREDEDOR DELPOSTE. ASEGÚRESE DE CLAVAR POR LO MENOS2 DE ELLOS EN LA PARTE SUPERIOR Y OTROS 2EN LA PARTE INFERIOR DEL POSTE DE 4X4, SISE PIENSA INSTALAR PASAMANOS, INSTÁLE-LOS TAMBIÉN A LA ALTURA REQUERIDA.

5. SLIDE THE 2ND L-SHAPED COLUMN HALF IN PLACE AND PUSHTHE MITERED EDGES TOGETHER. SCREW TOP AND BOTTOM OFTHE COLUMN SHAFT INTO THE TOP & BOTTOM SQUARINGBLOCKS. FASTEN THE COLUMN ALONG BOTH EDGES AS WELL ASATTACHING IT TO THE SQUARING BLOCKS. WE RECOMMEND FAS-TENING THE COLUMN EVERY 6 TO 8 INCHES USING 1-1/4” STA-PLES. FINISH NAILS WORK ALSO. WIPE OFF ANY ADHESIVE CAULKSQUEEZE-OUT WITH DAMP CLOTH. THE ADHESIVE CAULKCLEANS UP WITH WATER. IT IS IMPORTANT TO WIPE OFF THEEXCESS ADHESIVE CAULK BEFORE IT DRIES!

6. ATTACH THE BASE AND CAP COLLARS TO THE COLUMNSHAFT. APPLY ADHESIVE TO THE MITERED EDGES & WRAP THECOLLARS AROUND THE SHAFT AT THE TOP AND BOTTOM.FASTEN THE COLLARS TO THE SHAFT AND FASTNEN BOTHHALVES TOGETHER AT THE CORNERS. WIPE OFF ANY ADHESIVESQUEEZE-OUT WITH DAMP CLOTH. THE ADHESIVE CLEANS UPWITH WATER. IT IS IMPORTANT TO WIPE OFF THE EXCESSADHESIVE BEFORE IT DRIES! USE THE ADHESIVE CAULK TOCAULK THE SMALL GAP BETWEEN THE BACK OF THE COLLARSAND THE COLUMN SHAFT.

4. APPLY ADHESIVE CAULK TOTHE 2 MITERED EDGES OFTHE L-SHAPED COLUMNSHAFT.

LA COLUMNA DE PVC CARECE DE PROPIEDADES AUTOPOR-TANTES. La columna esta diseñada para ser instalada alrededor de unposte estructural existente. El poste estructural al interior de la colum-na, y suministrado por terceros, representa la característica estructur-al. La capacidad autoportante de la columna esta determinada por lascaracterísticas físicas del poste. El Arquitecto o el Ingeniero se encar-garán de especificar los requerimientos estructurales del poste. Elposte estructural debe ser ACQ, CCA o de otra madera inmunizada,ACQ, CCA, o de un elemento de madera reforzada e inmunizada o deacero. NO USE MADERA SIN INMUNIZAR COMO POSTES ESTRUC-TURALES, ya que esta puede ser afectada por infiltraciones de agua ocondensaciones dentro de la columna. El poste se debe asegurar alsuelo y a la viga usando solamente métodos y anclajes aprobados porel código de construcción.

ASPECTOS RELACIONADOS CON LA TEMPERATURA: Las columnas de PVC se tornan más frágiles al ser expuestas abajas temperaturas siendo más susceptibles al daño. Serecomienda ambientar las columnas a una temperatura de 50 o55 grados antes de instalarlas. Esto se puede lograr llevando lascolumnas a un lugar con calefacción y permitir que suba la temperatura de las columnas. Aunquela temperatura exterior sea bastante inferior a 50 grados, las columnas se pueden instalar si hansido previamente ambientadas reduciendo de esta manera la posibilidad de causarles daño. Si noes posible ambientar las columnas antes de instalarlas, UD deberá hacer unas perforaciones ini-ciales con una broca pequeña antes de usar tornillos o puntillas para el ensamblaje. Tenga cuida-do al usar puntillas de no golpear las columnas con el martillo. Tenga presente que si las columnastienen esquinas que no han sido previamente dobladas, es posible que se quiebren si no han sidoambientadas. En caso de que esto suceda, Ud. de todos modos tendrá 2 cuerpos con esquinas biendefinidas.

CORTES Y ASEGURAMIENTO El material de PVC usado para fabricar las columnas puede ser fácilmente cortado con herramien-tas convencionales de carpintería o ebanistería. Para ensamblar las columnas utilice pistolaspequeñas de aire para puntillas o grapas. Las pistolas grandes pueden ocasionar daño debido lapercusión que generan. Tornillos de rosca ancha y grapas galvanizadas o inoxidables para “SheetRock” también son recomendadas.

PINTURA Y ACABADOMacille cuando sea necesario usando el pegante suministrado por el fabricante. Rellene los huecosusando macilla acrílica. Suavemente lije y empareje la superficie de la columna. Use un detergenteliviano y agua, alcohol natural o limpiador de vidrios para limpiar el mugre o residuos de aceite.Asegúrese de remover residuos de jabón con agua limpia. Aplique una capa de base 100% acríli-ca y una o más capas de pintura para exteriores100% acrílica. No pintar las columnas con los col-ores oscuros (los colores oscuros son considerados de cualquier color que se encuentre dentro delvalor de L de 56 a 0). L es la medida de luminosidad de un objeto y va de 0 (negro) a 100 (blanco).

No instale por debajo del nivel.

Instrucciones de Instalacion paraColumna Cuadrada PermaWrap®

6. SITUE LOS COLLARES ALREDEDOR DE LA COLUMNA APLICANDO PEGANTE EN LOS BORDES ENANGULO. ASEGURE AMBAS A LA COLUMNA Y ENTRE ELLAS MISMAS LIMPIANDO EL PEGANTE ALFINALIZAR CON UN TRAPO HUMEDO. USE EL MISMO PEGANTE PARA SELLAR LOS ESPACIOS ENTRE LACOLUMNA Y LOS COLLARES.

4. APLIQUE EL PEGANTE A LOSBORDES DE UNA DE LAS SEC-CIONES EN “L”.

1. CORTE LA COLUMNA A LA DISTANCIA QUE NECESITE USANDO UNA SIERRA MANUAL O UNA ELECTRICA.

5. POSICIONE LA OTRA SECCIÓN EN FORMA DE “L” Y ATORNILLE LACOLUMNA A LAS ESCUADRAS INTERNAS TANTO ARRIBA COMOABAJO Y VERTICALMENTE A LO LARGO DE LAS UNIONES CADA 6 U8 INCHES USANDO GRAPAS DE 1-1/4” O PUNTILLAS PARA ACABA-DO. LIMPIE CON UNA TOALLA HÚMEDA LOS EXCESOS DE PEGANTEANTES DE QUE SE ENDUREZCAN.

72884 TKM back.QXP_27384 HBG 5/18/15 3:58 PM Page 1